Military Engineer Services-MES has published Tender For Repair, Maintenance And Servicing Of Dg Set Including Servicing Of Amf Panels And Connected Items At Af Stn Bhuj. Submission Date for this Tender is 09-03-2023. Diesel Generators Tenders in bhuj Gujarat. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 16-Feb-2023 | CHANGE IN CRITICAL DATE | Date | 25-02-2023 |
2 | 20-Feb-2023 | REVISED BOQ | BOQ | 27-02-2023 |
3 | 20-Feb-2023 | CHANGE IN CRITICAL DATE 1 | Date | 27-02-2023 |
4 | 27-Feb-2023 | Other | Other | 27-02-2023 |
5 | 27-Feb-2023 | CHANGE IN CRITICAL DATE | Date | 02-03-2023 |
6 | 02-Mar-2023 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 09-03-2023 |
Sl. No. | Item Description |
1 | Labour only for attending the emergent complaintof DG sets of 7.5 KVA to 320 KVA capacities installed at various locations of air force station bhuj. Carrying out general servicing and minor repairs and/or replacements, including following jobs whichever is required to make DG Set functional complete all as specified and directed by Engineer-in-Charge :- (i) Checking and cleaning of diesel filters & oil filters and making a list of filters required to be replaced. (ii) Checking of engine oil level and intimating the quantity of oil required for topping, if any. (iii) Checking, cleaning and servicing including oiling & greasing of engine and making list of repairs / replacements required, if any. (iv) Checking, cleaning, watering & general servicing of alternator battery including tightening of nuts, bolts, lugs and the like. Also making a list of repairs / replacements required, if any. (v) Checking the earthing connections of neutral and body of DG set, tightening of connections and making a list of repairs /replacements required, if any. |
2 | (vi) Checking of self starter and intimating Engr in charge if required to be repaired / specially serviced in workshop. (vii) Checking, cleaning and general servicing of AMF panel including replacement / tightening of nuts, bolts, lugs and other such minor parts, oiling & greasing and making list of repairs / replacements required, if any. (viii) Checking, cleaning & general servicing of instrument panel and making a list of repairs/ replacements required, if any. (ix) Checking, cleaning and general servicing of various parts of DG set such as timer, contactors , meters, etc. and making list of repairs / replacements required, if any. (x) Tightening / replacement of nuts, bolts, washers and the like of DG set all as directed. (xi) Checking for diesel leakage from any point and rectify if can be rectified by minor repairs / replacements. Else make list of repairs / replacements required, if any. (xii) Checking, cleaning and adjusting fan belt tension and making a list of replacements requirted, if any. (xiii) Checking, cleaning & general servicing of exhaust / silenecer including checking for leakage of smoke & rectify, if can be rectified by minor repairs / replacements. Else make a list of repairs / replacements required, if any. |
3 | (xiv) Checking, cleaning and tightenening of electrical connections including replacement of minor parts. (xv) Checking & cleaning of AVM pads, tightening / replacement of nuts, bolts, & washers and making a list of replacements required, if any. (xvi) Checking, cleaning & tightening of exhaust pipe, flange and lagging, tightening / replacement of nuts, bolts, washers and the like and making a list of repairs / replacements required, if any. (xvii)(a). Checking output of alternator and adjusting the same to specified values, in case of brush type (b) cleaning & servicing of the alternator, minor repairs & replacements and making list of alternators requiring complete overhauling (xviii) Checking, cleaning & tightening of all hose pipes, tightening / replacement of nuts, bolts, washers and the like and making a list of repairs / replacements required, if any. (xix) Checking, cleaning & servicing of air filter elements and making a list of replacements required, if any. (xx) Oiling, greasing and checking for proper functioning of DG set. |
4 | (Note - I. Rates quoted by the tenderer are also deemed to include the cost of supply & fix in replacement of minors parts like nuts, bolts, washers, lugs, etc., supply and applying oil & greasing and minor repairs to DG set. II. The work under this item is to be carried out as complaint recieved and as directed by the Engineer in charge. III. List of repairs / replacements prepared by the contractor shall be submitted to the Engineer in charge for verification. IV. The all mentioned above maintenance work carried outby contractor. |
5 | Material & labour for full servicing of DG Sets of capacity 7.5KVA to 63KVA complete all as specified and directed by Engineer-in-Charge as per following :- (i) Draining out engine/lubricant oil flushing including filling fresh oil afterdrain out old oil by skilled OEM trademan of DG set including replacement of oil pan /chamber gasket . (ii) Supply & fix in replacement lubricant oil filter element . (iii) Supply & fix in replacement fuel filter element. (iv) Supply & fix bypass filter element. (v) Checking and applying grease to battery terminals and checking its specific gravity including topping of distilled water /acid as required. (vi) General cleaning of oil/fuel spills, grease spots etc. (vii) Checking of belt tension and adjusting as per requirment. (viii) Check all electrical conditions. (ix)Check pollution level. (x) Change water separator and radiator cleaning with chemical. (xi) Change hydraulic governor oil, change aneroid oil, check aneroid adjustment, replace aneroid breather. (xii) Clean radiator externally, check fan hub/Idler and water pump/idler. (xiii) Inspect units, replace as required (Alternator/Generator,Starter etc), check air cleaner if required (Amount of air filter will be paid separately), evacuator valves change if required. |
6 | Material & labour for full servicing of DG Sets of capacity 70KVA to 160KVA complete all as specified and directed by Engineer-in-Charge as per following :- (i) Draining out engine/lubricant oil flushing including filling fresh oil afterdrain out old oil by skilled OEM trademan of DG set including replacement of oil pan /chamber gasket . (ii) Supply & fix in replacement lubricant oil filter element . (iii) Supply & fix in replacement fuel filter element. (iv) Supply & fix bypass filter element. (v) Checking and applying grease to battery terminals and checking its specific gravity including topping of distilled water /acid as required. (vi) General cleaning of oil/fuel spills, grease spots etc. (vii) Checking of belt tension and adjusting as per requirment. (viii) Check all electrical conditions. (ix)Check pollution level. (x) Change water separator and radiator cleaning with chemical. (xi) Change hydraulic governor oil, change aneroid oil, check aneroid adjustment, replace aneroid breather. (xii) Clean radiator externally, check fan hub/Idler and water pump/idler. (xiii) Inspect units, replace as required (Alternator/Generator,Starter etc), check air cleaner if required (Amount of air filter will be paid separately), evacuator valves change if required. |
7 | Material & labour for full servicing of DG Sets of capacity 320KVA complete all as specified and directed by Engineer-in-Charge as per following :- (i) Draining out engine/lubricant oil flushing including filling fresh oil afterdrain out old oil by skilled OEM trademan of DG set including replacement of oil pan /chamber gasket . (ii) Supply & fix in replacement lubricant oil filter element . (iii) Supply & fix in replacement fuel filter element. (iv) Supply & fix bypass filter element. (v) Checking and applying grease to battery terminals and checking its specific gravity including topping of distilled water /acid as required. (vi) General cleaning of oil/fuel spills, grease spots etc. (vii) Checking of belt tension and adjusting as per requirment. (viii) Check all electrical conditions. (ix)Check pollution level. (x) Change water separator and radiator cleaning with chemical. (xi) Change hydraulic governor oil, change aneroid oil, check aneroid adjustment, replace aneroid breather. (xii) Clean radiator externally, check fan hub/Idler and water pump/idler. (xiii) Inspect units, replace as required (Alternator/Generator,Starter etc), check air cleaner if required (Amount of air filter will be paid separately), evacuator valves change if required. |
8 | Material & labour for preparing old painted surface of DG sets (complete including engine, alternator, body & chases) by thoroughly cleaning the surfaces to remove dirt, dust, rust flakes and paint flakes, using wire brush or sand papers, damp cloth or as directed. Priming the surface with anti corrosive primers using suitable sprayers. Applying automotive paint using sprayers till glossy finish is obtained, complete all as per manufacturers instructions and writting MES Number in block capital letters complete all as specified and directed by Engineer-in-Charge. |
9 | Supply only lead acid battereies for DG set complete all as specified and directed by Engineer-in-Charge of following capacity:-(Maintenance free battery of 2 years warranty) |
10 | 88 AH,12 Volt. |
11 | 150 AH,12 Volt. |
12 | 180 AH,12 Volt. |
13 | Repair and maintenanceof FIP including replacement of Plunzers, Governer kit with pin, Nozzles P type,Head ball guide kit, Head sheet (set of 12 piece) rock rod, rollar bearing, oil seal, piston pin, gasket kit and sleeves complete all as specified and directed by Engineer-in-Charge DG set of following capacity:- |
14 | DG Set Upto 25 KVA |
15 | DG Set 30 to 50 KVA |
16 | DG Set 62.5 to 75 KVA |
17 | DG Set 82.5 to 100 KVA |
18 | DG Set 125 to 320 KVA |
19 | Material & labour for taking out radiator of DG set 7.5 KVA to 50KVA for repair, welding, brazing, leak testing, descaling & refixing to DG set to its original position and testing complete all as specified and directed by Engineer-in-Charge. |
20 | Material & labour for taking out radiator of DG set 62.5 KVA to 100 KVA for repair, welding, brazing,leak testing, descaling & refixing to DG set to its original position and testing complete all as specified and directed by Engineer-in-Charge. |
21 | Material & labour for taking out radiator of DG set 125 KVA to 320 KVA for repair, welding, brazing,leak testing, descaling & refixing to DG set to its original position and testing complete all as specified and directed by Engineer-in-Charge. |
22 | Taking out the charging alternator of DG Set of following capacityand shifting to workshop for rewinding of armature including replacement of rewindingunserviceable, bushes & minor parts & reinstalling the same after testing complete all as specified and directed by Engineer-in-Charge of following:-. |
23 | DG set of capacity upto 15 KVA |
24 | DG set of capacity 25 to 37.5 KVA |
25 | DG set of capacity 50 KVA |
26 | DG set of capacity 62.5/63 KVA |
27 | DG set of capacity 70 to 82.5 KVA |
28 | DG set of capacity 100 to 320 KVA |
29 | Supply & fix in replacement solenoid switch for 200 to 320 KVA DG set and testing complete all as specified and directed by Engineer-in-Charge for proper functioning. |
30 | Supply & fix in replacement solenoidswitch for 160 KVA DG set and testing complete all as specified and directed by Engineer-in-Charge for proper functioning. |
31 | Supply & fix in replacement solenoidswitch for 100 to 125 KVA DG set and testing complete all as specified and directed by Engineer-in-Charge for proper functioning. |
32 | Supply & fix in replacement solenoid switch for 70 to 82.5 KVA DG set and testing complete all as specified and directed by Engineer-in-Charge for proper functioning. |
33 | Supply & fix in replacement solenoidswitch for 62.5/63 KVA DG set and testing complete all as specified and directed by Engineer-in-Charge for proper functioning. |
34 | Supply & fix in replacement solenoidswitch for 15 to 50 KVA DG set and testing complete all as specified and directed by Engineer-in-Charge for proper functioning. |
35 | Supply & fix in replacement of AMF Relay suitable for DGsets complete all as specified and directed by Engineer-in-Charge. |
36 | Supply & fix in replacement of single phase preventor complete all as specified and directed by Engineer-in-Charge. |
37 | Supply & fix in replacement of PLA relay complete all as specified and directed by Engineer-in-Charge. |
38 | Supply & fix in replacement 3 pole power contractor ML-1.5,25 A,415 V complete all as specified and directed by Engineer-in-Charge. |
39 | Supply & fix in replacement 3 pole power contractor ML-2,32/40 A,415 V complete all as specified and directed by Engineer-in-Charge. |
40 | Supply & fix in replacement 3 pole power contractor ML-3,40/45 A,415 V complete all as specified and directed by Engineer-in-Charge. |
41 | Supply & fix in replacement 3 pole power contractor ML-4,70 A,415 V complete all as specified and directed by Engineer-in-Charge. |
42 | Supply & fix in replacement 3 pole power contractor ML-6,110/125 A,415 V complete all as specified and directed by Engineer-in-Charge. |
43 | Supply & fix in replacement 3 pole power contractor ML-10,200/250 A,415 V complete all as specified and directed by Engineer-in-Charge. |
44 | Supply & fix in replacement of HRC fuse base of capacity 125 to 250 Amps complete all as specified and directed by Engineer-in-Charge. |
45 | Removing, transporting to workshop, repairing & servicing of self starter of DG set ranging from 7.5 KVA to 320 KVAincluding replacement of parts such as washer, nut, bolts, bush, solonoid, rotor etc., reassembling and testing complete all as specified and directed by Engineer-in-Charge. |
46 | Descaling of water jacket of engine by using descaling solution with pressure circulation pump,leak testing, soldering, brazing, checking for leaks and recirculating with clear water complete all as specified and directed by Engineer-in-Charge for following DG sets:- |
47 | Up to 63 KVA DG Set |
48 | 70 KVA to 160 KVA DG Set |
49 | 200 KVA to 320 KVA DG Set |
50 | Supply & fix in replacement "V" belt for radiator fan complete all as specified and directed by Engineer-in-Charge for following DG Set:- |
51 | Upto 50 KVA |
52 | 62.5 to 82.5 KVA |
53 | 100 to 320 KVA |
54 | Replacement / filling up/ top up of engine oil (20 W 40) suitable for DG sets complete all as specified and directed by Engineer-in-Charge. |
55 | Replacement / filling up/ top up of pre mix coolant suitable for DG Set complete all as specified and directed by Engineer-in-Charge. |
56 | Material & labour for cleaning of diesel tank of DG Set"tank cleaned onDate………..complete all as specified and directed by Engineer-in-Charge. |
57 | Supply & fix in replacement of anti vibration pad suitable for 25 to 320 KVA DG setcomplete all as specified and directed by Engineer-in-Charge. |
58 | Supply & fix in replacement of air cleaner filter for DG Set capacity 200 KVA to 320 KVA complete all as specified and directed by Engineer-in-Charge. |
59 | Supply & fix in replacement of air cleaner filter for DG Set capacity70 KVA to 160 KVA complete all as specified and directed by Engineer-in-Charge. |
60 | Supply & fix in replacement of air cleaner filter for DG Set capacity7 KVA to 63 KVA complete all as specified and directed by Engineer-in-Charge. |
61 | Supply & fix in replacement of hose pipe set suitable for following capacity of DG sets & complete all as specified and directed by Engineer-in-Charge for following. |
62 | Up to 63 KVA DG set |
63 | 70 KVA to 160 KVA DG set |
64 | 200KVA to 320 DG set |
65 | Supply & fix in replacement of AVR suitable for following capacity of DG Sets & complete all as specified and directed by Engineer-in-Charge for following. |
66 | Up to 50 KVA DG set |
67 | 62.5 to 125 KVA DG set |
68 | 160 to 320 KVA DG set |
69 | Supply & fix in replacement of battery lugs complete all as specified and directed by Engineer-in-Charge. |
70 | Supply & fix in replacement of ignition switch suitable for DG sets & complete all as specified and directed by Engineer-in-Charge. |
71 | Supply & fix in replacement of self starter suitable forup to 25 to 50 KVA DG Set 12 Volt complete all as specified and directed by Engineer-in-Charge. |
72 | Supply & fixin replacement ofself starter suitable for 62.5 to 82.5KVA DG Set 12 Volt complete all as specified and directed by Engineer-in-Charge. |
73 | Supply & fix in replacement ofself starter suitable for 100 to 125 KVA DG Set 12 Volt complete all as specified and directed by Engineer-in-Charge. |
74 | Supply & fix in replacement ofself starter suitable for 160 to320KVA DG Set 24 Volt complete all as specified and directed by Engineer-in-Charge. |
75 | Repair/replacementwiring (till 5 m) of DG Set/AMF panel upto 25 to 50 KVA complete all as specified and directed by Engineer-in-Charge. |
76 | Repair/Replacementwiring (till 5 m) of DG Set/AMF panel 62.5 to 100 KVA complete all as specified and directed by Engineer-in-Charge. |
77 | Repair/Replacementwiring (till 5 m) of DG Set/AMF panel 125 to 320 KVA complete all as specified and directed by Engineer-in-Charge. |
78 | Supply & fix in replacement of of battery charger of 6 Amps for 12 Volt battery complete all as specified and directed by Engineer-in-Charge. |
79 | Supply & fix in replacement of battery charger of 6 Amps for 24 Volt battery complete all as specified and directed by Engineer-in-Charge. |
80 | Supply & fix inreplacement ofwater pump complete for 35 to 320 KVA DG set complete all as specified and directed by Engineer-in-Charge. |
81 | Supply & fix in replacement ofdiesel pipe filter to pump for DG set complete all as specified and directed by Engineer-in-Charge. |
82 | Supply & fix in replacement of diesel pipe filter to tank for DG set complete all as specified and directed by Engineer-in-Charge. |
83 | Supply & fix in replacement radiator up to 82.5 KVA DG set complete all as specified and directed by Engineer-in-Charge. |
84 | Supply & fix in replacement radiator from100 to 160 KVA DG set complete all as specified and directed by Engineer-in-Charge. |
85 | Supply & fix in replacement DG set power controller up to 50 KVA DG set complete all as specified and directed by Engineer-in-Charge. |
86 | Supply & fix in replacement DG Set power controller from 62.5 to 125 KVA DG set complete all as specified and directed by Engineer-in-Charge. |
87 | Supply & fix in replacement DG set power controller from 160to 320 KVA DG set complete all as specified and directed by Engineer-in-Charge. |
88 | Supply & fix in replacement MCCB"s,415 Volts, 3 / 4 pole ,with adjustable thermal & fixed magnetic settings having complete all as specified and directed by Engineer-in-Charge. for following capacities :- |
89 | Upto 63 Amps 16 KA 3 Pole |
90 | 100 Amps 25 KA 3 Pole |
91 | 125 Amps 25 KA 3 Pole |
92 | 160 Amps 36 KA 3 Pole |
93 | 200 Amps 36 KA3Pole |
94 | 250 Amps 36 KA3 Pole |
95 | Supply & fix Diesel pump with pipe assembly to make it fully fuctional and fixing it to its original position of DG set in any capacity including replacement necessary element complete all as specified and directed by Engineer-in-Charge. |
96 | Supply & fix Selector Switch 4/6 base complete all as specified and directed by Engineer-in-Charge. |
97 | Material & labour for complete checking of AMF panel,finding the fault,servicing complete includingas per site and replacement of unserviceable spares and testing complete for manual & auto operations complete all as specified and directed by Engineer-in-Charge. (Note:- Supply only of new items required for replacement will be measured & paid seperately under respective item of schedule.) |
98 | Supply & fix distiled water suitable for battery ofDG set complete all as specified and directed by Engineer-in-Charge. |
99 | Opening the coupling of DG set of capacity 200 to 320 KVA , dismantling the outer cover & taking out the fly wheel ring and shifting to workshop for repair in and including replacement of fly wheel ring by pressing machine and reinstalled the same after repair to make it fully fuctional complete all as specified and directed by Engineer-in-Charge. |
100 | Opening the coupling of DG set of capacity 7.5 to 63 KVA, dismantling the outer cover & taking out the fly wheel ring and shifting to workshop for repair in and including replacement of fly wheel ring by pressing machine and reinstalled the same after repair to make it fully fuctional complete all as specified and directed by Engineer-in-Charge. |
101 | Opening the coupling of DG set of capacity 70 KVA to 160 KVA, dismantling the outer cover & taking out the fly wheel ring and shifting to workshop for repair in and including replacement of fly wheel ring by pressing machine and reinstalled the same after repair to make it fully fuctional complete all as specified and directed by Engineer-in-Charge. |
102 | Material & labour for calibration of fuel injector assembly of DG set of 70KVA to 160 KVA capacity at authorised workshop including replacement of cup, barrel and plunger injector washer etc complete all as specified and directed by Engineer-in-Charge. |
103 | Material & labour for calibration of fuel injector assembly of DG Set of7.5KVA to 63KVA capacity at authorised workshop including replacement of cup, barrel and plunger injector washer etc complete all as specified and directed by Engineer-in-Charge. |
104 | Material & labour for calibration of fuel injector assembly of DG Set of 200KVA to 320 KVA capacity at authorised workshop including replacement of cup, barrel and plunger injector washer etc complete all as specified and directed by Engineer-in-Charge. |
105 | Supply & fix in replacement ofbentex wheel complete suitable for self starter complete all as specified and directed by Engineer-in-Charge. |
106 | Supply & fix in replacement of battery copper cable red with plug of size 35 sqmm complete all as specified and directed by Engineer-in-Charge. |
107 | Supply & fix in replacement ofbattery copper cable black with plug of size 35 sqmm complete all as specified and directed by Engineer-in-Charge. |
108 | Supply & fix in replacement fan assembly along with hub suitable for DG Set of any cap complete all as specified and directed by Engineer-in-Charge. |
109 | Supply & fixing in replacement three phase Volt Meter of size 96x96x80mm, flush mounting on panel 0 to 500 Volts, digital type, with built in selector switch complete all as specified and directed by Engineer-in-Charge. |
110 | Supply & fixing in replacement three phase Amps Meter of size 96x96x80mm, flush mounting on panel 0 to 200 Volts, digital type, with built in selector switch complete all as specified and directed by Engineer-in-Charge. |
111 | Taking out the alternator of DG set of capacity 7.5 KVA to 320 KVA and shifting to workshop for rewinding of armature including replacement of rewinding unserviceable, bushes & minor parts & reinstalling the same after testing complete all as specified and directed by Engineer-in-Charge. |
112 | Material & labour for earthing complete with copper earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including copperearth strip 32X6mm by means ofnut, bolts, check nuts and washers of copper/ bronze as shown in electrical plate No.3 of SSR Part-I (2009) complete all as specified and directed including testing on completion including the material and labour complete all as specified and directed by Engineer-in-Chargeof the following : - (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 15 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing. |
113 | Complete overhauling of DG set capacity 125 KVA with dismantling of exhaust piping, fuel piping, HP pipes, inlet mainfold, hoses, Cy head, injectors and other related assessories and top overhauling CR bearing, con rod, piston, piston ring, cylinder liner and major overhauling charges watre pump, oil cooler HE, crank shaft, main bearing, thrust washer etc and reassembling with required torque tappet setting and trail and refixing of following items at original position etc complete all as specified and directed by Engineer-in-Charge. |
114 | Supply only cylinder liner complete all as specified and directed by Engineer-in-Charge. |
115 | Supply only piston complete all as specified and directed by Engineer-in-Charge. |
116 | Supply only piston ring complete all as specified and directed by Engineer-in-Charge. |
117 | Supply only inlet valve complete all as specified and directed by Engineer-in-Charge. |
118 | Supply only exhaust valve complete all as specified and directed by Engineer-in-Charge. |
119 | Supply only valve seat inlet complete all as specified and directed by Engineer-in-Charge. |
120 | Supply only valve seat exhaust complete all as specified and directed by Engineer-in-Charge. |
121 | Supply only valve guide complete all as specified and directed by Engineer-in-Charge. |
122 | Supply only HCT switch complete all as specified and directed by Engineer-in-Charge. |
123 | Supply only injector nozzle complete all as specified and directed by Engineer-in-Charge. |
124 | Supply only delivery valve complete all as specified and directed by Engineer-in-Charge. |
125 | Supply only pipe set complete all as specified and directed by Engineer-in-Charge. |
126 | Supply only connecting rod assly DL-4complete all as specified and directed by Engineer-in-Charge. |
127 | Supply only set gasket complete all as specified and directed by Engineer-in-Charge. |
128 | Supply only head gasket complete all as specified and directed by Engineer-in-Charge. |
129 | Supply only set of fuel flex complete all as specified and directed by Engineer-in-Charge. |
130 | Supply only con rod bush complete all as specified and directed by Engineer-in-Charge. |
131 | Supply only con rod bearing complete all as specified and directed by Engineer-in-Charge. |
132 | Supply only oil pressure guage complete all as specified and directed by Engineer-in-Charge. |
133 | Supply only water temp guage complete all as specified and directed by Engineer-in-Charge. |
134 | Supply only ammeter complete all as specified and directed by Engineer-in-Charge. |
135 | Supply only LLOP switch complete all as specified and directed by Engineer-in-Charge. |
136 | Supply only sealing ring complete all as specified and directed by Engineer-in-Charge. |
137 | Supply only AVM complete all as specified and directed by Engineer-in-Charge. |
138 | Supply only T/C KIT complete all as specified and directed by Engineer-in-Charge. |
139 | Supply only AVM for meter box complete all as specified and directed by Engineer-in-Charge. |
140 | Supply only nut M10 complete all as specified and directed by Engineer-in-Charge. |
141 | Supply only bolt 8x25 complete all as specified and directed by Engineer-in-Charge. |
142 | Supply only bolt 10x30 complete all as specified and directed by Engineer-in-Charge. |
143 | Supply only set of O ring complete all as specified and directed by Engineer-in-Charge. |
144 | Supply only set of hose clip complete all as specified and directed by Engineer-in-Charge. |
145 | Supply only set of hoses complete all as specified and directed by Engineer-in-Charge. |
146 | Material & labour of diod to be fixed in alternator complete all as specified and directed by Engineer-in-Charge. |