Tender For Thanjavur District Construction Of Community Hall Building At Ambalapattu South Panchayat In Orathanadu Block Of Thanjavur District Under Mlacds 2021-22.
Tender Value
1.90 Crore
Estimated cost
Bid Submission
09 Feb 2023
0 days left
EMD
1.90 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
orathanadu → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Thanjavur District Construction Of Community Hall Building At Ambalapattu South Panchayat In Orathanadu Block Of Thanjavur District Under Mlacds 2021-22.
BOQ
| Sl. No. | Item Description |
| 1 | Construction of Community Hall in Ambalapattu South Panchayat. |
| 2 | Earth work excavation for foundation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by thedepartmental officers with an initial lead of 10 mts and initial lift of 2 mts. and clearing and levelling the site, etc., complete complying with standard specification. |
| 3 | Supplying and filling in foundation, basement, etc with fillingM.sand in layers of not more than 10 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers. |
| 4 | PLAIN CEMENT CONCRETE 1:4:8 mix using 40mm gauge hand broken hard granite stone jelly for FOUNDATION including dewatering if found necessary and laid in layers of not more than 10cm thick, well rammed etc., complete complying with standard specification. |
| 5 | Refilling with excavated earth other than sand with an initial head load of 100 mts. and depositing the earth as shown by the departmental officersin layers of not more than 15 cm thick well rammed, watered and consolidated etc. complete complying with standard specification |
| 6 | Supplying and filling of conveyed Gravel by lorry in Basement filling including stacking forPre-measurementconveyanceloadingandunloadingchargesandallother incidentalchargesincludingfilling,layering,wateringandconsolidationetc., complete as directed by the dept. officers and complying with standard specification |
| 7 | Brick work in following Cement Mortar 1:5 using best quality II class table moulded chamber burnt bricks of size 9\" x 4-3/8\" x 2-3/4\" for foundation and basement including curing etc.,complete complying with standard specification.including scaffolding curing cost of reinforcement etc.all complete as per specifications and drawings as directed by the Engineer in-charge. |
| 8 | upto basement |
| 9 | Ground Floor |
| 10 | First floor |
| 11 | Head room |
| 12 | Supplying and Erecting Steel Centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oakjoists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc.complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid). |
| 13 | upto basement |
| 14 | Ground Floor |
| 15 | First floor |
| 16 | Circular Column Ground Floor |
| 17 | Head room |
| 18 | Reinforced Cement Concrete 1:11/2:3(One Cement, One and a half sand and Three hard broken stone jelly) using 20 mm gauge hard broken granite stone jelly for all RCC items of works excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary and bearing surfaces of walls, beams etc. shall be finished smooth with Cement Mortar 1:3 (One Cement and Three Sand) etc., complete complying with standard specification and as directed by the departmental officers |
| 19 | upto basement |
| 20 | Ground Floor |
| 21 | First floor |
| 22 | Head room |
| 23 | Steel - Fe 500 D: Supply, fabrication and placing of reinforcement steel of high yield strength ribbed bars of various diameters and grade conforming to IS 1786 for reinforced concrete work. The work includes recoiling, straightening, cutting, bending, fabricating, and placing in position, at all levels including lead and lift, according to drawings, specifications etc. complete and supply & use of 18G black annealed binding wire double fold to tie the bars in position and providing precast cement/ PVC cover blocks for main reinforcement to ensure specified cover and complete., including all labor charges etc as directed by departmental officers. |
| 24 | Providing and applying 10 mm thick Cement plaster in Cement mortar 1:3 ( One part of Cement and Three parts of M.Sand ), to finishing the exposed surfaces of R.C.C. items of works such as Roof (or) floor slabs, beams, and Sun shades etc.to correct plane and level including scaffolding, hacking of surface, chiselling the undulated surface wherever necessary and curing etc., all materials and labour complete in all respects including all lead, lift and descent and as directed by the Enineer in charge. This rate includes the cost of providing Cement Mortar beadings for sun shades, steps,landing slabs, elevation etc. complete complying with standard specifications. |
| 25 | Providing & applying 12 mm thick cement plaster in CM 1:5 (1 part of cement: 5 parts of M.sand) to walls internally in single coat at all levels to correct line and level including chicken wire mesh at all joints of brick and concrete surfaces with minimum overlap of 150 mm in all directions, scaffolding, rounding off or chambering of corners, offsets, fin/ bands, projections, etc. and cleaning of surface, raking out joints, roughening of surface,chiseling the undulated surface wherever necessary and curing, etc., all materials and labor complete in all respects including all lead, lift and descent andas directed. |
| 26 | Flooring with Vertified tiles size 600x600x8mm laid over 20 mm thick cement mortar 1:3 (One Cement and Three Sand)base mortar over the existing slab / floor including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with white cement mixed with colouring pigment at the rate of 0.3 Kg. / sq.m. etc., complete complying with standard specification. |
| 27 | Paving the floor with pre-polished concrete anti-skid tiles (Required shape and design) of 20mm thick of approved quality and colour laid in Cement Mortar 1:3 (One Cement and Three crushed stone M.Sand) 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers.(The make and brand of the tiles should be got approved by Executive Engineer before use on works)Using anti-skid tiles (Observed Data) |
| 28 | Paving the floor with pre-polished concrete anti-skid step tiles (Required shape and design) of 20mm thick of approved quality and colour laid in Cement Mortar 1:3 (One Cement and Three crushed stone M.Sand) 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers.(The make and brand of the tiles should be got approved by Executive Engineer before use on works) |
| 29 | Providing granolithic floor finish in cement concrete 1:2:4 mix using 10-12mmISS metal to 25mm thick including cost and conveyance of all materials to site and all labour charges for mixing, laying, curing etc complete for 10 cum |
| 30 | Dadooing walls with best approved quality, colour glazed tiles of 300mm x 200mm x 6mm size set in Cement Mortar 1:2 (One Cement and Two sand) 10mm thick and pointing the joints with white cement mixed with colouring pigments at the rate of 0.40 Kg. / sq.m. neatly in all floors, curing, etc., complying with standard specification and as directed by the departmental officers. |
| 31 | Weathering Course Concrete using best quality broken brick jellyof 20 mm uniform guage in pure slaked lime ( NO Sand to be used ( over the RCC roof slab in the proportion of brick jelly to lime being 32 : 121/2 by volume laid over in single layer and consolidated to the required slope and finished thickness and beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime, jaggery water etc. complete complying with standard specifications |
| 32 | Finishing the top of roof with one course of Machine pressed tiles of size 230mm x 230mm x 20mm of approved quality set in Cement Mortar 1:3 (One Cement and Three Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers. |
| 33 | Painting two coats of synthetic Enamel paint of approved colour and make over one coat of anti corrosive Zinchromite primerover new wood / steel work, suitably prepared for receiving the paint by surface scraping, rubbing applying filler etc. including cost of filler, primer, paint all complete as per drawings and specifications. |
| 34 | Supplying and painting the walls with two coats of oil bound distemper over one coat of water based cement primer including cost for distemper, primer, cleaning and scrapping the walls, rendering the wallssmooth with necessary putty, brushes, scaffolding arrangements, labour charges, etc., as per standard specification.(The colour and shade of the distemper shall be got approved by the Executive Engineer before use of work). |
| 35 | Painting two coats of newly plastered wall surface with ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of Paris putty, wherever required etc., complete complying with standard specification. |
| 36 | Supplying Fabricating and Fixing in position of AluminiumAnodised Natural Colour Matt finish, Powder coated Glazed door ( Double leaved of size 1.20m x2.10m = 2.52m2) 12mm thick both side prelaminated particle board using rectangular box section of 101.60x44.45x3.18xmm at 2.319 Kg/m with the following shutter frame and necessary such as rubber beading, handle, lock furniture fittings including cost of materials and labour and power consumption sharges required for fabrication including necessary clipping dismatling and making necessary holes in Rcc columns, Beams, Masonry with power drill to the required extent and redoing the same to the original condition agter fixing etc., complete. The Aluminium for frame are to be anodised with Matt finish, Powder coated under electrically controlled condition in accordance with nISI specification 1869/1962 and thickness for anodic film thickness of not less than 15 micrepms that pf [;aom glass shall be 5.50mm etc., complete complying with standard specification. (All materials should be got approved by the Executive Engineer) Alu.section for outer frame of size 101.6x44.45x3.18 at 2.31Kg/m. |
| 37 | Manufacturing, supplying and fixing of Steel doors with following specification.MS angle of size 40x40x6mm at 3.5 kg/m used for outer frame and MS Angle of size 35x35x5mm at 2.6 Kg/m for the shutter frame.Stiffeners with 32x6mm at 1.5 Kg/m MS Flat is provided as the lock rail of the door and welded intact on both ends to the shutter frame.18 G CR Sheets of best quality is laid as panel in theshutter frames.18x5mm at 0.70 kg/m MS flat is welded over the 32x6mm at 1.50kg/m MS Flat on the rear side of the door, sandwiching the CR Sheet for rigidity. Additional stiffeners with 18x5mm at 0.7 Kg/m MS flats are provided diagonally on the rear side of the shutter. 300mm length ofhinges 2Nos, for shutter is provided.6 Nos. of 250mm length hold fasts 200mm length specified at the ends are welded to the outer frame of the door.Tower bolt 2 Nos. at the top provided. |
| 38 | Solid PVC Door shutter using 19 gauge 19mm MS sq. tubes for styles and outer frames, 15mm MS sq. tubes for top, lock and bottom rails.The steel tubes shall be covered with 5mm thick solid PVC sheets.Shutter using 5mm thick solid PVC sheets for paneling shall rigidly fixed in position including necessary furniture and fittings. The over all size of styles shall be 50mm x 30mm.The over all size of top rail, lock rail and bottom rail shall be 75mm x 30mm.The over all size of frames shall be 50mm x 45mm, with suitable suitable rebate for housing the shutter. |
| 39 | Providing and fixing sliding windows/doors, fabricated from unplasticised polyvinyl chloride UPVC) sections with hollow pofile, three chamber system to provide high insulation properties with outer frame 108mm x 45mm and an outer wall thickness of 2.2mm. All corner, joints midred and fusion welded. Frame reinforced with 31 x 11mm & 23 x 20 x 5mm steel of 1mm thickness. The sash of size 39 x 58mm.Profiles with co-extruded seals. All the hardware like rollers, handles screwed with self tapping screws.The handles & locks designed to operate from inside only. The window systemglazed with 5mm plain float glass. The profiles cut to length and welded at 45 degrees. The window unit designed such that the water drainage does not pass through the reinforcement chamber.The window system fixed directly to the brick wall using self expanding nylon plug and driving M.S. electroplated screws into plug. etc., complete. The brand should be approved by the Executive Engineer. |
| 40 | Supplying and fixing of M.S.grill of approved design for grill gate, grill work to doors and windows openings etc., using necessary mild steel etc., complete complying with standard specification. |
| 41 | UPVC VENTILATOR:Supplying and fixing UPVC (Un-PLASTICIZED Polyvinyl chloride)Louvered Ventilators of from the profile the size of outer frame 60x58mm and shutter profile the size of 60x78mm both profile size of 60x78mm both profiles are reinforced with GI/1MM 125GSMand 100% corrosion free,the profile are mulit chambered sections withwall thick of 2mm.The EPDM rubber ( black colour) covered with all over he edgesof frame and shutter.The corners and joints should be welded and cleaned.Radiation pin headed glass 4mm thick should be fixed to the wall with 100% packing with screws and silicon packing all aroundthe frame.The ventilator should be got approved from the Executive Engineer before use on work. |
| 42 | Supply and Fixing Thickness of Cuddapaa slab for Cubboard 25mm with polished cuddapah slab including cost and conveyance of all Labour charges etc complete |
| 43 | Supplying and fixing in position S.S.Handrails using 40mm pipes of 2mm thickness spaced at 900mm centre to centre and the top connected with 40mm pipe hand rails by means of SS pipes of 20 MM size two nos provided at the bottom of hand rail; the bottomshall be fixed on to the top of step concrete. etc., complete complying with standard specification and as directed by the departmental officers. |
| 44 | Manufacturing,supplying and fixing of stainless steel handrails for staircase using 50mm dia 304L grade stainless steel pipe of 1.6mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia stainless steel pipe post of 1mm thick as vertical at 900mm centre with 2 Nos of 25mm dia intermediate horizontal stainless steel pipe of 1.6mm thick in between.The vertical pipe has to be welded to the 100 x 100 x 6mm MS base plate encased in the base concrete.The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance,electrical charges,ect.complete. |
| 45 | Electrical Arrangements |
| 46 | Wiring with 2x1.5sqmm (22/0.3) PVC insulated unsheathed SC Cu. Conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessoires with Metal switch box and 5A Modular switch in flush with wall with suitable top plate cover for making good of the concealed portion with suitable colour for PVC concealed light point / fan point (For electronic regulator) SD - 24 Modified |
| 47 | Wiring with 2x1.5 sqmm (22/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessoires in flush with wall with top plate cover with Metal switch box and 5A Modular switch and making good of the concealed portion with suitable colour for PVC concealed light / Fan Point (For electronic regulator) (5 Points Per Coil) SD - 25 Modified |
| 48 | Wiring with 2x1.5 sqmm (22/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessoires in flush with wall with suitable top cover with Metal switch box and 5A Modular switch and making good of the concealed portion with suitable colour for PVC concealed light (6 Points Per Coil) (For Rooms like Bath , Toilet,& Pump room etc..) (SD-26 Modified) |
| 49 | Wiring with 2x1.5sqmm (22/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories, in flush with wall, with 150mm x 100mm x 113mm Metal switch box with suitable top cover for 5 A 3 pin non inter locking CS Modular Plug with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour for concealed PVC plug point. (SD-38 Modified) |
| 50 | Supply and fixing of fancy glass shade and 11W CFLfor BH point.(SD-80) |
| 51 | Supply and fixing of single box type 4\"36 W flu fitting complete with electronic ballast with TW round blocks on wall or ceiling with flu tube with PVC unsheathed Copper leads fromterminals to the fitting. (SD-87) |
| 52 | Supply and fixing of 4\" 40 W Twin Mirror optic suspension type fitting (Philips / Crompton / Wipro) complete with louvers cover complete with copper choke and condensor with conduit pipe suspension, with PVC unsheathed Copper leads from the terminals to the fittings with flu. tubes (SD-96) |
| 53 | Supply & Fixing of AC / DC 76mm Buzzer / call bell suitable for 230 Volts 50 c/s single phase AC supply on suitable Metal Board with modular push switch. (SD-105 Modified) |
| 54 | Supply and fixing of 1200 mm (48\") AC ceiling fan complete with stepped electronic 300W regulator with 300mm down rod on the existing clamp. (SD-110) |
| 55 | Supply and fixing of 300 mm (12\") sweep (light duty) AC exhaust fan complete with necessary wall opening and making good of the wall (SD-114) |
| 56 | Supply and fixing of louvers shutters arrangements for 300 mm (12\") sweep (light duty) AC exhaust fan. (SD-120) |
| 57 | Supply and fixing of 5A / 15A 3 pin combined flush type modular wall socket with 15A flush type Modular switch on suitable Metal Box (SD-136 Modified) |
| 58 | Supply and fixing of 3 Nos. 5Amps (3 Pin and 2 Pin) combined flush type Modular wall socket with modular control switches concealed in suitable Metal Box covered withsuitable top plate in flush with wall with earth connection (For Computer Plug Socket) (SD-139 Modified) |
| 59 | Supply and fixing of 20Amps DP Plug and Socket in sheet enclosure with 32A DP MCB in flush with wall with earth connection (For AC Plug) [Legrand (MDS) / Hager (L&T) make] (SD-140) |
| 60 | Supply and fixing of 1 x 45w CFL type street light fitting complete with 19mm dia GI pipe (class “B”) on the existing post / wall with PVC unsheathed copper leads MS clamps and aluminium painting with CFL (CG / Philips or Equivalent) (DATA-A) |
| 61 | Supply and run of 4 of 6 sq.mm (84/0.3) PVC insulated SC unsheathed Cu Conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection by 14 SWG TC wire and making good of the concealed portion with suitable colour DATA-B SD73 |
| 62 | Supply and fixing of vertical type 4 way TPMCBSS in sheet steel enclosive ire63 4 pole MCB as incoming and 3 Nos 40A TPMCS 3 NOS 32A SPMCS AS Outgoing inflush with wall andSupply and fixing of Horizontal type 4 way triple pole neutral MCB distribution board in sheet steel enclosure with 40A 4 pole MCB isolater as incoming and 12 Nos. 6 A to 32 A SP MCB as outgoing in flush with wall and making good of the concealed portion with earth connection. The MCBDB and MCB\"s should be with the ISI mark (like standard make)DATA-C |
| 63 | Supply and run of 2 of 1.5 sqmm (22/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100V Grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection 14 SWG TC wire with painting of suitable colour. (SD-54) |
| 64 | Supply and run of 2 of 1.5 sqmm (22/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100V Grade in rigid pipe concealed in wall and ceiling with continuous earth wire connection of 14SWG TC wire and making good of the concealed portion with suitable colour (SD-55) |
| 65 | Supply and run of 4 of 6 sq.mm (84/0.3) PVC insulated SC unsheathed Cu Conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection by 14 SWG TC wire and making good of the concealed portion with suitable colour (SD-63) |
| 66 | Supply and fixng of TNEB Moter Board suitable for 3 Phases 63A service connection made up of suitable angle iron frame work of size 2 feet x 1 1/2 feet using angle iron of size 1 1/2\" x 1 1/2\" x 1/4\" rigidly fixed on wall covered with hylem sheet of size 2 feet x 1/2 feet of 6mm thickness with necessary bolts and nuts supports and supply and fixing of 3 Nos 63A fuse units (500V) 1 No. Neutral link, copper earth flat of size 1\" x 1/4\" with inter connection of EB meter to fuse units by 7/16 PVC insulated copper wire with earth connection complete SD 129 |
| 67 | Supply and fixing of 63A TPN MC switch with suitable angle iron frame work with MS cable entry boxes with earth connection only.Supply and fixing of 8 way single pole and neutral MCB sheet steel enclosure Distribution board 1No 32 Amps DB MCB as incoming and 6 Nos 6 Amps to 32 Amps SPMCB outgoing in flush with wall and making good of the concealed portion with earth connection only. The MCB DB and MCB\"s should be with ISI mark (Like Standard make).SD-166 |
| 68 | Supply and fixing of 8 way single pole and neutral MCB sheet steel enclosure Distribution board 1No 32 Amps DB MCB as incoming and 6 Nos 6 Amps to 32 Amps SPMCB outgoing in flush with wall and making good of the concealed portion with earth connection only. The MCB DB and MCB\"s should be with ISI mark (Like Standard make). (SD-167) |
| 69 | Supply and fixing of Horizontal type 4 way triple pole neutral MCB distribution board in sheet steel enclosure with 40A 4 pole MCB isolater as incoming and 12 Nos. 6 A to 32 A SP MCB as outgoing in flush with wall and making good of the concealed portion with earth connection. The MCBDB and MCB\"s should be with the ISI mark (like standard make) (SD-179) |
| 70 | Supply and fixing of brass cable gland for 2 x 10 sq.mm PVC armoured LTUG cable, with earth connection SD-182 |
| 71 | Supply and fixing of brass cable gland for 3 1/2 x 35 sqmm PVC armoured LTUG cable with earth connectionSD-187 |
| 72 | Supply and laying of 2 x 10 sq.mm PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 mt. Layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good. SD-198 |
| 73 | Supply and laying of 31/2 X 50 sq.mm PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 mt. Layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good.SD-205 |
| 74 | Supply and clarnping of 2 x 6 sq.mm PVC LTUG armoured cable on post or on wall with MS Clamps. SD-215 |
| 75 | Supply and laying of 31/2 x 120 sq.mm PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 mt. Layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good. SD-223 |
| 76 | Earthing as per the ISI specification with an earth electrode of 2.1mt class \"B\" GI pipe of dia not less than 40mm, with copper earth plate of size 125mm x 50mm x 6mm, with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonrySD-233 |
| 77 | Supply and fixing of 4\"40 W twin street light flu. fitting complete With copper choke and condensor with 19mm dia GIpipe (Class \"B\") with 1 No. 19mm GI Bend complete on the existing post / wall With 16 A aerial fuse unit on MS platewith PVC unsheathed Cu. leads, with MS clarnps and aluminium painting with Flu. Tubes SD95 |
| 78 | Supply and fixing of WT bulk head fitting (Philips / Bajaj / K.Lite / Crornpton Greaves ) suitable for incandescent lampwith guard and 100 W bulb. SD 85 |
| 79 | Supply and fixing of vertical type 4 way TPMCBSS in sheet steel enclosive ire63 4 pole MCB as incoming and 3 Nos 40A TPMCS 3 NOS 32A SPMCS AS Outgoing inflush with wall andSupply and fixing of Horizontal type 4 way triple pole neutral MCB distribution board in sheet steel enclosure with 40A 4 pole MCB isolater as incoming and 12 Nos. 6 A to 32 A SP MCB as outgoing in flush with wall and making good of the concealed portion with earth connection. The MCBDB and MCB\"s should be with the ISI mark (like standard make)DATA-C |
| 80 | Paverblock Arrangements |
| 81 | Earth work excavation for foundation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by thedepartmental officers with an initial lead of 10 mts and initial lift of 2 mts. and clearing and levelling the site, etc., complete complying with standard specification. |
| 82 | Supplying and filling in foundation, basement, etc with fillingM.sand in layers of not more than 10 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers. |
| 83 | PLAIN CEMENT CONCRETE 1:4:8 mix using 40mm gauge hand broken hard granite stone jelly for FOUNDATION including dewatering if found necessary and laid in layers of not more than 10cm thick, well rammed etc., complete complying with standard specification. |
| 84 | Construction of Granular Sub base by providing well graded material (25 mm to 4.75 mm IRC HBG metal @ 65 %,4.75 to 2.36mm IRC HBG metal@20%&2.36 mm below IRC HBG metal @15%)& (the material passing 425 microns sieve shall have liquid limit and plasticity index not more than 25 & 6% repectively) spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with rotovator at OMC and compacting with three wheel 80-100 KN capacity and finished in accordance with the requirements of the specification and thickness as per approved plans or as directed by the Engineer (Mix -in - place method). |
| 85 | Cement concrete 1:3:6 mix ( one cement four M.sand and eight aggregate) using 20mm gauge handbroken granite tone jelly for foundation including dewatering if found ecessary and laid in layers of not more than 15 cm thick and compacted,etc., complete complying withstandard specfication |
| 86 | Providing and Laying of Interlocking concrete Block Pavements specification clause 1504 usingM30 grade rupper moduled interlocking63 mm thickness paver block |
| 87 | Supplying and Erecting Steel Centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oakjoists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc.complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid). |
| 88 | Plumbing Arrangements |
| 89 | Supplying and fixing of Indus floor mounted white colour European water closet Parryware or equivalent, with seat cover and dual flush (3 & 6 lit) cistern having P trap withseat cover, supplyingnon corrosive hinges, CP bolts, nuts, washers, providing and fixing dash anchor fastners with bolts / L -brackets with anticorrosive paint cutting grooves in masonry or concrete surfaces, groutingwith cement concrete 1:2:4 mix, using 20mm size stone jelly, restoring the damaged portion to their original condition using required materials, fixing the water closet to perfect level, alignment, testingetc. complete. |
| 90 | Supplying and fixing in positon Indian Water Closet (Oriya type) of size 580 x 440mm white glazed earthern ware of approved quality and brand with \"P\" or \"S\" trap conforming to BIS with crushed stone M.Sandcushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One lime, Two crushed stone M.Sandand Five brick jelly) 100mm thick and finishing the top to the required slope and including giving necessary connection to CI soil pipes (including the cost of 100mm dia CI pipe for a length of 600mm) by dismantling brick masonry wall / reinforced cement concrete roof / floor slab and making good the dismantled portion to the original condition with leakages etc., complete complying with standard specifications and as directed by the departmental officers.(The water closet should be got approved by the Executive Engineer before use on works). |
| 91 | Supply & Fixing of two in one CP Health Faucet of the closet mounting type with hose connected two way BIB COCK complete fittings. (Make: Parryware or equivalent) |
| 92 | Providing and keeping in stores, shifting to the place of installation, fixing,testing and commissioning ofWHITE coloured vitreous china under counterRegular rectangularwash basin with brackets/ G.I. rag bolts and nuts painted,32mm dia brass C.P. waste coupling, (heavy) 32mm diabrassC.P.bottletrap,15mmdiabrassC.P.Anglestopcockwith flange, 15mm dia brass C.P. coldwater connecting pipe, etc., The work shall include,required extension nipples, cutting / chasing and making good the walls and floors-toilets. |
| 93 | Supply & Fixingat sitein position 15mm dia C.P brass BIB COCKS long body with wall flangeincludingcuttingandmakinggoodthe wallswhereverrequired |
| 94 | Supplying & fixing ofAngle valve stopcock with connecting hose and wall flange. (Make: Parryware or equivalent) |
| 95 | Supplying and fixing approved best quality brass CP towel rail 600mm long and 20mm dia with brackets of same materials including cost of teak wood plugs and CP screws, etc., complete complying with standard specifications. (The tower rail should be got approved by Executive Engineer before use on works). |
| 96 | Supplying and fixing in position Indian make bevelled edge mirror of approved quality and brand PVC / Fibre Glass framed 600 x 450 x 5.5mm thick mirror, shelf type with hard board backing of approved colour fixed with brass screws, rawl plug, etc., complete complying with standard specification. (The mirror should be got approved by the Executive Engineer before use on woks). |
| 97 | Supplying and fixing best approved best quality CP stop cock 15mm dia including cost of brass screws, etc., complete complying with standard specifications. |
| 98 | PART - B SOIL, WASTE AND VENT PIPE LINES |
| 99 | Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages,etc., complete complying with standard specifications.(The PVC pipes should be got approved by the Executive Engineer before use on works). The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid below ground level. |
| 100 | 40mm dia. 10kg class PVC pipes. |
| 101 | 50mm dia. 6kg class PVC pipes. |
| 102 | 75mm dia. 6kg class pipes. |
| 103 | 110mm dia. 6kg class pipes. |
| 104 | Supplying and fixing in position PVC nahini /Floor Trap with PVC Grating type of size 100x75/75x50 mm with best quality gratings of approved brand fixed over a bed of brick jelly lime concrete 1:2:5(One lime two sand and five aggregate) brick jelly 40mm and finishing with CM 1:3(One cement and three sand)wherever found necessary and making good to the original condition and giving connections to the PVC pipes etc., complete complying with standard specification and as directed by the Departmental Officer. |
| 105 | Supply and fixing in position best quality PVC IS 4985 - CLASS-II - 4 Kg/Sqcm -Rain water pipes of various size having ISI mark and providing leak proof joints with such asBend, Tee Junction, door etc.,of approved qualityincluding fixing to the wall with special PVC /MS clamps, etc., and making connection to all sanitary fittings, wherever necessary and making chipping good to the original condition, complying with standard specification etc., complete. |
| 106 | 75mm dia. 6kg class PVC pipes. |
| 107 | 160mm dia. 6kg class pipes. |
| 108 | Supplying and fixing in position of the following dia PVC rain water gratings for rain water pipes ,of approved quality and varietyof various size confirming to ISS andincluding necessary cutting and fixing and giving connection to PVC pipes etc., complete complying with standard specification and as directed by the Departmental Officer |
| 109 | 75mm x 50mm |
| 110 | 100mm x 75mm |
| 111 | Supplying and fixing in position of the following dia PVC specials such asPVC vent Cowl etc.,of approved quality and varietyof various size confirming to ISS amend providing leak proof joint etc., including necessary cutting and fixing and giving connection to PVC pipes etc., complete complying with standard specification and as directed by the Departmental Officer |
| 112 | 75mm dia |
| 113 | 110mm dia |
| 114 | PART-C - EXTERNAL DRAINAGE |
| 115 | Supply and fixing in position best quality PVC IS 4985 - CLASS- III - 6 Kg/Sqcm -Soil/ waste pipes of various size with approved quality and varietyof various size confirminghaving ISI mark and providing leak proof joints including erection of below groundwith excavation and refilling etc., and making connection to Manholes / Gully trap, wherever necessary and making chippinggood portion to the original condition, complying with standard specification etc.,complete. |
| 116 | 160mm dia. 6kg class III-pipes. |
| 117 | Supply, laying and erction of glazed stone ware gully trap (100 x 75 mm) with 100 mm dia, outlet including embedding trap in cement concrete 1:3:6 and constructing chamber of size 300 x 300 mm inside clear in brick masonry 230 mm thick, plaster with water proof cement mortar (1:3) 15 mm thick on both internal and external surfaces inside finished with floating coat of neat cement. The work including excavation to required depth of gully trap and refilling and making good in the surface withProviding and fixing SFRC frame and cover 400 x 400 mm (clear opening) complete complying with std. specification. |
| 118 | Supplying and Erection and construction of sewer chambers of required internal dimensions 600x600 upto 0.6 mtr.depth with 230mm brick masonry in C.M.1:5 thk of masonry over bed of1:2:4 R.C.C. 200 mm thk bove 100 mm thk P.C.C.1;3:6 Cement concrete foundations over sand bed of 100mm thk channelling in 1;2:4 cement concrete, plastering in 1:3 cement mortar for internal and external surface finished with floating coat of neat cement, the work including excavation for required depth of gully trap and refilling and making good in the surface with SFRC cover and frame 600x600mm (clear opening)complete complying with standard specifications etc., |
| 119 | Construction of rain water recharge well of 1200mm dia and depth upto 1500mm, in addition 110 dia special blue slotted pipe for bore well.pipe should be laid from bottom of ring well centre to below 1500mm as shown in the drawings, including all types of excavation,occur for pipe, filling of rain water harvesting materials with construction of R.C.C. ring and top 100mm RCC SLAB WITH 450X450mm perforated SFRC manhole and 230mm brick wall in 2\"height with below 300mm lengthx100mm thk P.C.C. as per the structural filling the filter media as per drawing. |
| 120 | D. WATER SUPPLY SYSTEM |
| 121 | Internal Concealed Works |
| 122 | Providing, supplying & laying of Chlorinated Poly Vinyl Chloride (CPVC-SDR-11) Pipes conforming to IS 15778 having thermal stability cold water with brass and CPVC fittings like Elbow,Brass Tee, Brass Elbow,Offsets,Tee with clamps @1.00 meters spacing, with jointing of pipes with one step CPVC solvent cement with including cutting of chase including testing of the joints complete and making good the walls etc.Rate is inclusive of all material labour, transportation,tools & tackles taxes,levies VAT etc all complete as per as per specifications,Concealed work including chase cutting) complete complying with standard specification and as directed by the Departmental Officer. |
| 123 | 20 mm nominal (OD) pipes |
| 124 | 25 mm nominal (OD) pipes |
| 125 | E.EXPOSED PLUMBING WORKS |
| 126 | Providing, supplying & laying of Chlorinated Poly Vinyl Chloride (CPVC-SDR-11) Pipes conforming to IS 15778 having thermal stability cold water with brass and CPVC fittings like Elbow,Brass Tee, Brass Elbow,Offsets,Tee with clamps @1.00 meters spacing, with jointing of pipes with one step CPVC solvent cement with including cutting of chase including testing of the joints complete and making good the walls etc.Rate is inclusive of all material labour,transportation,tools & tackles taxes, levies VAT etc all complete as per as per specifications, Exposed work including chase cutting, bracket fixing)complete complying with standard specification and as directed by the Departmental Officer. |
| 127 | 32mmnominal(OD) pipes |
| 128 | 40mmnominal(OD) pipes |
| 129 | F. EXTERNAL PLUMBING WORKS |
| 130 | Providing, supplying & laying of Chlorinated Poly Vinyl Chloride (PVC) Pipes conforming to IS 15778 having thermal stability cold Metro water with brass and PVC fittings like Elbow, Brass Tee, Brass Elbow, Offsets, Tee with clamps @1.00 meters spacing, with jointing of pipes with one step PVC solvent cement with including cutting of chase including testing of the joints complete and making good the walls etc.Rate is inclusive of all material labour,transportation, tools & tackles taxes, levies VAT etc all complete as per as per specifications,Concealed work including chase cutting) complete complying with standard specification and as directed by the Departmental Officer. |
| 131 | 32mmPVC pipes |
| 132 | 110mmPVC pipes |
| 133 | Providing, supplying & laying of Gunmetal type NRV - pressure rating less tahn 16 Kg/Sqcm and IS778 with 2 Nos of MTA with jointing material like shellac, thread including testing of the joints complete and making good the walls etc. Rate is inclusive of all material labour, transportation, tools & tackles taxes, levies VAT etc all complete as per as per specifications, complete complying with standard specification and as directed by the Departmental Officer. |
| 134 | 25 DIA |
| 135 | 32 DIA |
| 136 | PROVISION FOR SEPTIC TANK |
| 137 | Earthwork for foundationsand depositing on bank with initial lead of 10 Mt. and initial lift of 2 Mt. in sand, silt or other loose soil, wet sand or silt not under water, light black cotton soil, sandy loam and ordinary soilincluding excavated earth. |
| 138 | Supplying and filling in foundation and basement with M sand in layers of not more than 10cm thick well watered, rammed and consolidated etc., complete as per standard specification. |
| 139 | Laying the Plain Cement concrete 1:4:8(One cement four sand and eight brokenMachine crushed stone jelly) using HBG Machine creased Machine crushed stone jelly of size 40mm gauge for founding and basement including de- watering if found necessary and laid in layers of not more than 15cms thick etc., complete complying with standard specification and as directed by the departmental officers.The rates inclusive of Centering , shuttering, strutting, propping,removal of form work if it is required and all leads ,lifts and curing etc.. |
| 140 | Supplying and Erecting centering for sides and soffits including necessary supports and strutting up to 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at about 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specification. (Payment for centering shall be given after the concrete is laid) |
| 141 | Brick work in following Cement Mortar using best quality of Country Bricks of size 8-3/4\" x 4-1/4\" x 2-3/4\" for foundation and basement including curing, etc., complete complying with standard specifiction. |
| 142 | REINFORCED CEMENT CONCRETE 1:1.5:3 mixusing 20mm machine crushed 20mm gauge hard broken granite stone jelly for all reinforced cement concrete works connected to this work excluding cenetering, shuttering and cost of reinforcement grills placed in position, but including laying, vibrating, curing and finishing, fixing fan clamps in the RCC floor and roof slab works wherever necessary and bearing surfaces of the wall at the sides and bottom of the slab, beams shall be finished smooth with cement mortar 1:3 (One cement and three sand ) and Kraft paper laid without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers. |
| 143 | Providing & applying 12 mm thick cement plaster in CM 1:5 (1 part of cement: 5 parts of sand) to walls internally and externally in single coat at all levels to correct line and level including chicken wire mesh at all joints of brick and concrete surfaces with minimum overlap of 150 mm in all directions, scaffolding, rounding off or champhering of corners, offsets, fin/ bands, projections, etc. and cleaning of surface, raking out joints, roughening of surface,chiseling the undulated surface wherever necessary and curing, etc., all materials and labour complete in all respects including all lead, lift and descent andas directed. |
| 144 | Supplying and fixing in position C.I.Manhole covers (heavy duty) mof various sizes of best approved quality and as per standard specificationsetc., complete.0.6X0.6M Size etc., complete. |
| 145 | Providing, machine mixing and laying on the P.C.C/ R.C.C. surface in approved panels of25 mm thick granolithic flooring in cement concrete mix of 1:2:4 (1 Cement: 2 Sand: 4 Aggregate 10 to 12 mm thick)well vibrated,compacted including 45 X 3 mm glass dividing strip, fixed to correct level and finished smooth and cured by keeping surfaces well-covered and protected against excess of an type. (The contractor to provide for preparation of surface by cleaning, hacking and exposing aggregate to achieve the best bond and any curling, lifting or beybonding noticed shall be rectified by the contractor at his cost). |
| 146 | Supplying, fabricating and placing in position mild steel/Ribbed tor steel rods for all RCC works including cost of steel and binding wire also in all floors, complete complying with standard specfication. |
| 147 | Provision for Nameboard |
| 148 | GST Amount for providing Service to Government Contract Works for the above Construction Works. { GST Amount is the Total GST Amount for total overall quoted amount above this row in column \"BB\" for all works in this package} |
AI Tender Summary
Tender Timeline
Feb 03, 2023
11:30 IST
Tender Published
Tender notice published.
CompletedFeb 09, 2023
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedFeb 09, 2023
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender