Repair /Replacement To Lt Panels, Apfc Panels And Other Connected Items At Af Stn Sarsawa Under Ge (Af) Sarsawa, sarsawa-Uttar Pradesh

Military Engineer Services-MES has published Repair /Replacement To Lt Panels, Apfc Panels And Other Connected Items At Af Stn Sarsawa Under Ge (Af) Sarsawa. Submission Date for this Tender is 04-03-2023. Electrical Panel Tenders in sarsawa Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

36056830
Corrigendum : Repair /Replacement To Lt Panels, Apfc Panels And Other Connected Items At Af Stn Sarsawa Under Ge (Af) Sarsawa
Open Tender
Indian
Uttar Pradesh
sarsawa
04-03-2023

Tender Details

Repair / Replacement To Lt Panels, Apfc Panels And Other Connected Items At Af Stn Sarsawa Under Ge ( Af ) Sarsawa

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 09-Feb-2023 AMDT01 Terms and Conditions 25-02-2023
2 15-Feb-2023 AMDT02 Other 25-02-2023
3 25-Feb-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 04-03-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 40000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: REPAIR /REPLACEMENT TO LT PANELS, APFC PANELS AND OTHER CONNECTED ITEMS AT AF STN SARSAWA UNDER GE (AF) SARSAWA
Sl. No. Item Description
1Supply, installation, testing & commissioning in replacement offloor mounted PTT LT Power distribution feeder pillars outdoor type, complying to IS 5039 standard suitable for 415V, 3 phase, 4 wire, 50 Hz, factory made out of 40 x 40 x 6 mm angle iron frame and 3.15 mm thick CRCA sheet double door type, floor mounting, having partially type tested assemblies as per IS 8623, Minimum IP55 degree of protection to be proided as per IS 12063-1987 / IEC 60529.includingall accessorieslike lamps, push buttons, interlocks, CT, PT, Meters with RS485 connectivity, SPD,etc as per Specification sheet.Thefaultlevelforthe board shall be 50kA for 1sec. The panel shall be inline with relevant IS code, TC, TDS & SLD"s. The door shall have three point locking arrangement. Special type tamperproof heavy duty built-in inter-lock with appropriate key shall be provided. . The door shall be provided with pad-locking facility also. Earthingbus bar and stud with plate to be provided both side of LT Panel.All Incomer shall be provided with a set ofVIF meters , CT, ON indication lamps, phase indicating lights etc,All incommer and outgoing MCCB to be provided with Rotary operating handle.SPD as to be provided as IS 16463 : Part 12 : 2017/IEC 61643-12:2008 Low - Voltage surge protective devices: Part 12.all as specified and directed by the Engr-in-charge. Note: Feeder pillar box shall be mounted on PCC 1:2:4 type B-1 (with 20 mm graded stone aggregate) foundation block of suitable size upto 40 cm above ground level as directed.The cost of the PCC block shall be deemed to be included in the unit rate quoted for the item & width of the panel not less than 75 cm).The switchgear & encloseure shold be same make.(For STN ARMOURY) Incommer :-200A FP Manually Operated Fixed Type MCCB (36kA) with built-in Thermal Based Release for (O/C, S/C Protection),+ROH-01 No. Dual Source Digital Mutifunction Meter with RS485-01 No. CTs 200/5A, Class-0.1, 15VA for Metering (Resin Cast)-03 Nos. Indicating lamps - R/Y/B-03 Nos. 6A SP Control MCB (10kA), C-Curve-03 Nos. Outgoing :- 100A FP Manually Operated Fixed Type MCCB (25KA) with built-in Thermal Based Release for (O/C, S/C Protection),+ROH-02 Nos 63A FP Manually Operated Fixed Type MCCB (25KA) with built-in Thermal Based Release for (O/C, S/C Protection),+ROH- 01 Nos. Future Space for MCCB-01 Nos.
2Supply, installation, testing & commissioning in replacement of floor mounted PTT, LT Power distribution feeder pillars outdoor type, complying to IS 5039 standard suitable for 415V, 3 phase, 4 wire, 50 Hz, factory made out of 40 x 40 x 6 mm angle iron frame and 3.15 mm thick CRCA sheet double door type, floor mo-unting, having partially type tested assemblies as per IS 8623, Minimum IP55 degree of protection to be proided as per IS 12063-1987 / IEC 60529.includingall accessorieslike lamps, push buttons, interlocks, CT, PT, Meters with RS485 connectivity, SPD,etc as per Specification sheet.Thefaultlevelforthe board shall be 50kA for 1sec. The panel shall be inline with relevant IS code, TC, TDS & SLD"s. The door shall have three point locking arrangement. Special type tamperproof heavy duty built-in inter-lock with appropriate key shall be provided. . The door shall be provided with pad-locking facility also. Earthingbus bar and stud with plate to be provided both side of LT Panel.All Incomer shall be provided with a set ofVIF meters , CT, ON indication lamps, phase indicating lights etc,All incommer and outgoing MCCB to be provided with Rotary operating handle.SPD as to be provided as IS 16463 : Part 12 : 2017/IEC 61643-12:2008 Low - Voltage surge protective devices: Part 12.all as specified and directed by the Engr-in-charge. Note: Feeder pillar box shall be mounted on PCC 1:2:4 type B-1 (with 20 mm graded stone aggregate) foundation block of suitable size upto 40 cm above ground level as directed.The cost of the PCC block shall be deemed to be included in the unit rate quoted for the item & width of the panel not less than 75 cm).The switchgear & encloseure shold be same make.(For OLD ATC & BCR) Incommer :- 200A FP Manually Operated Fixed Type MCCB (36kA) with built-in Thermal Based Release for (O/C, S/C Protection),+ROH-01 No. Dual Source Digital Mutifunction Meter with RS485-01 No. CTs 200/5A, Class-0.1, 15VA for Metering (Resin Cast)-03 Nos. Indicating lamps - R/Y/B-03 Nos. 6A SP Control MCB (10kA), C-Curve-03 Nos. Outgoing :- 200A FP Manually Operated Fixed Type MCCB (25KA) with built-in Thermal Based Release for (O/C, S/C Protection),+ROH-02 Nos. Future Space for MCCB-01 No.
3Supply, installation, testing & commissioning in replacement of floor mounted PTT, LT Power distribution feeder pillars outdoor type, complying to IS 5039 standard suitable for 415V, 3 phase, 4 wire, 50 Hz, factory made out of 40 x 40 x 6 mm angle iron frame and 3.15 mm thick CRCA sheet double door type, floor mo-unting, having partially type tested assemblies as per IS 8623, Minimum IP55 degree of protection to be proided as per IS 12063-1987 / IEC 60529.includingall accessorieslike lamps, push buttons, interlocks, CT, PT, Meters with RS485 connectivity, SPD,etc as per Specification sheet.Thefaultlevelforthe board shall be 50kA for 1sec. The panel shall be inline with relevant IS code, TC, TDS & SLD"s. The door shall have three point locking arrangement. Special type tamperproof heavy duty built-in inter-lock with appropriate key shall be provided. . The door shall be provided with pad-locking facility also. Earthingbus bar and stud with plate to be provided both side of LT Panel.All Incomer shall be provided with a set ofVIF meters , CT, ON indication lamps, phase indicating lights etc,All incommer and outgoing MCCB to be provided with Rotary operating handle.SPD as to be provided as IS 16463 : Part 12 : 2017/IEC 61643-12:2008 Low - Voltage surge protective devices: Part 12.all as specified and directed by the Engr-in-charge. Note: Feeder pillar box shall be mounted on PCC 1:2:4 type B-1 (with 20 mm graded stone aggregate) foundation block of suitable size upto 40 cm above ground level as directed.The cost of the PCC block shall be deemed to be included in the unit rate quoted for the item & width of the panel not less than 75 cm).The switchgear & encloseure shold be same make.(For IT, EDP section ) Incommer :-200A FP Manually Operated Fixed Type MCCB (36kA) with built-in Thermal Based Release for (O/C, S/C Protection),+ROH-01 No. Dual Source Digital Mutifunction Meter with RS485-01 No. CTs 200/5A, Class-0.1, 15VA for Metering (Resin Cast)-03 Nos. Indicating lamps - R/Y/B-03 Nos. 6A SP Control MCB (10kA), C-Curve-03 Nos. Outgoing :- 160A FP Manually Operated Fixed Type MCCB (25KA) with built-in Thermal Based Release for (O/C, S/C Protection),+ROH-01 No. 100A FP Manually Operated Fixed Type MCCB (25KA) with built-in Thermal Based Release for (O/C, S/C Protection),+ROH-02 Nos. 63A FP Manually Operated Fixed Type MCCB (25KA) with built-in Thermal Based Release for (O/C, S/C Protection),+ROH-01 No. Future Space for MCCB
4Supply, installation, testing & commissioning in replacement of floor mounted PTT, LT Power distribution feeder pillars outdoor type, complying to IS 5039 standard suitable for 415V, 3 phase, 4 wire, 50 Hz, factory made out of 40 x 40 x 6 mm angle iron frame and 3.15 mm thick CRCA sheet double door type, floor mo-unting, having partially type tested assemblies as per IS 8623, Minimum IP55 degree of protection to be proided as per IS 12063-1987 / IEC 60529.includingall accessorieslike lamps, push buttons, interlocks, CT, PT, Meters with RS485 connectivity, SPD,etc as per Specification sheet.Thefaultlevelforthe board shall be 50kA for 1sec. The panel shall be inline with relevant IS code, TC, TDS & SLD"s. The door shall have three point locking arrangement. Special type tamperproof heavy duty built-in inter-lock with appropriate key shall be provided. . The door shall be provided with pad-locking facility also. Earthingbus bar and stud with plate to be provided both side of LT Panel.All Incomer shall be provided with a set ofVIF meters , CT, ON indication lamps, phase indicating lights etc,All incommer and outgoing MCCB to be provided with Rotary operating handle.SPD as to be provided as IS 16463 : Part 12 : 2017/IEC 61643-12:2008 Low - Voltage surge protective devices: Part 12.all as specified and directed by the Engr-in-charge. Note: Feeder pillar box shall be mounted on PCC 1:2:4 type B-1 (with 20 mm graded stone aggregate) foundation block of suitable size upto 40 cm above ground level as directed.The cost of the PCC block shall be deemed to be included in the unit rate quoted for the item & width of the panel not less than 75 cm).The switchgear & encloseure shold be same make.(For Gangotri) Incommer :-400A FP Manually Operated Fixed Type MCCB (36kA) with built-in Thermal Based Release for (O/C, S/C Protection),+ROH-01 No. Dual Source Digital Mutifunction Meter with RS485-01 No. CTs 400/5A, Class-0.1, 15VA for Metering (Resin Cast)-03 Nos. Indicating lamps - R/Y/B-03 Nos. 6A SP Control MCB (10kA), C-Curve-03 Nos. Outgoing :-250A FP Manually Operated Fixed Type MCCB (25KA) with built-in Thermal Based Release for (O/C, S/C Protection),+ROH-02 Nos. 200A FP Manually Operated Fixed Type MCCB (25KA) with built-in Thermal Based Release for (O/C, S/C Protection),+ROH-01 No. Future Space for MCCB
5Supply, installation, testing & commissioning in replacement offloor mounted PTT, LT Power distribution feeder pillars outdoor type, complying to IS 5039 standard suitable for 415V, 3 phase, 4 wire, 50 Hz, factory made out of 40 x 40 x 6 mm angle iron frame and 3.15 mm thick CRCA sheet double door type, floor mo-unting, having partially type tested assemblies as per IS 8623, Minimum IP55 degree of protection to be proided as per IS 12063-1987 / IEC 60529.includingall accessorieslike lamps, push buttons, interlocks, CT, PT, Meters with RS485 connectivity, SPD,etc as per Specification sheet.Thefaultlevelforthe board shall be 50kA for 1sec. The panel shall be inline with relevant IS code, TC, TDS & SLD"s. The door shall have three point locking arrangement. Special type tamperproof heavy duty built-in inter-lock with appropriate key shall be provided. . The door shall be provided with pad-locking facility also. Earthingbus bar and stud with plate to be provided both side of LT Panel.All Incomer shall be provided with a set ofVIF meters , CT, ON indication lamps, phase indicating lights etc,All incommer and outgoing MCCB to be provided with Rotary operating handle.SPD as to be provided as IS 16463 : Part 12 : 2017/IEC 61643-12:2008 Low - Voltage surge protective devices: Part 12.all as specified and directed by the Engr-in-charge.Note: Feeder pillar box shall be mounted on PCC 1:2:4 type B-1 (with 20 mm graded stone aggregate) foundation block of suitable size upto 40 cm above ground level as directed.The cost of the PCC block shall be deemed to be included in the unit rate quoted for the item & width of the panel not less than 75 cm).The switchgear & encloseure shold be same make.(For AF School) Incommer :-200A FP Manually Operated Fixed Type MCCB (36kA) with built-in Thermal Based Release for (O/C, S/C Protection),+ROH-01 No. Dual Source Digital Mutifunction Meter with RS485-01 No. CTs 200/5A, Class-0.1, 15VA for Metering (Resin Cast)-03 Nos. Indicating lamps - R/Y/B-03 Nos. 6A SP Control MCB (10kA), C-Curve-03 Nos. Outgoing :- 100A FP Manually Operated Fixed Type MCCB (25KA) with built-in Thermal Based Release for (O/C, S/C Protection),+ROH-04 Nos. Future Space for MCCB
6Supply, installation, testing & commissioning in replacement offloor mounted PTT, LT Power distribution feeder pillars outdoor type, complying to IS 5039 standard suitable for 415V, 3 phase, 4 wire, 50 Hz, factory made out of 40 x 40 x 6 mm angle iron frame and 3.15 mm thick CRCA sheet double door type, floor mo-unting, having partially type tested assemblies as per IS 8623, Minimum IP55 degree of protection to be proided as per IS 12063-1987 / IEC 60529.includingall accessorieslike lamps, push buttons, interlocks, CT, PT, Meters with RS485 connectivity, SPD,etc as per Specification sheet.Thefaultlevelforthe board shall be 50kA for 1sec. The panel shall be inline with relevant IS code, TC, TDS & SLD"s. The door shall have three point locking arrangement. Special type tamperproof heavy duty built-in inter-lock with appropriate key shall be provided. . The door shall be provided with pad-locking facility also. Earthingbus bar and stud with plate to be provided both side of LT Panel.All Incomer shall be provided with a set ofVIF meters , CT, ON indication lamps, phase indicating lights etc,All incommer and outgoing MCCB to be provided with Rotary operating handle.SPD as to be provided as IS 16463 : Part 12 : 2017/IEC 61643-12:2008 Low - Voltage surge protective devices: Part 12.all as specified and directed by the Engr-in-charge.Note: Feeder pillar box shall be mounted on PCC 1:2:4 type B-1 (with 20 mm graded stone aggregate) foundation block of suitable size upto 40 cm above ground level as directed.The cost of the PCC block shall be deemed to be included in the unit rate quoted for the item & width of the panel not less than 75 cm).The switchgear & encloseure shold be same make.(For 117 HU) Incommer :-100A FP Manually Operated Fixed Type MCCB (36kA) with built-in Thermal Based Release for (O/C, S/C Protection),+ROH-01 No. Dual Source Digital Mutifunction Meter with RS485-01 No. CTs 100/5A, Class-0.1, 15VA for Metering (Resin Cast)-03 Nos. Indicating lamps - R/Y/B-03 Nos. 6A SP Control MCB (10kA), C-Curve-03 Nos. Outgoing :-63A FP Manually Operated Fixed Type MCCB (25KA) with built-in Thermal Based Release for (O/C, S/C Protection),+ROH-02 Nos. Future Space for MCCB
7M&L for Serviceing of power factor control paneloutdoor/indoor type by fixing of broken hinged doors with welding , replacement of locking arrangement, handle, burnt /rusted out,bus bar as per existing size and shape, control rewiring ,loose or burnt thimble of any size ,old rusted/burnout nuts/bolts & washers, complete tighening of all nuts/bolts insulation tape to all joints refixing of any loose switchgear,cable glands, all unservicable control MCB 5 to 63 Amps, complete including scrapping of surfaces of LTpanel of size upto 3 mtr x 2 mtr x 1.5 mtr, applying two coats of synthetic enameled paint after one coat of primer ,cleaning/cutting of nearby grass bushes all as specified and as directed.
8S&F in replacement of Double door three phase prewired distribution board4 way TPN made out of CRCA sheets 1.6 mm thick,phosphatised powder coated with copper Bus Bar200 Amps, 415 V, Earth Stud, Din Rail, Polymide terminal blocks for incoming and outgoing circuits, inbuilt loose wire box ,ground terminal blocks ,duly prewired with thimbled flame retardant copper conductors and poly layer for protection in and includingMCCB4 pole 63 Amp rating repturing capacity 16 KA (Note:- Single Phase MCBs are to be measured and paid for seperately)
9M&L for Serviceing of LT panel outdoor/indoor type by fixing of broken hinged doors with welding , replacement of locking arrangement, handle, burnt /rustedout,bus bar as per existing size and shape, control rewiring ,loose or burnt thimble of any size ,old rusted/burnout nuts/bolts & washers,complete tighening of all nuts/bolts insulation tape to all joints refixing of any loose switchgear,cable glands complete including scrapping of surfaces of LTpanel of size upto 3 mtr x 2 mtr x 1.5 mtr, applying two coats of synthetic enameled paint after one coat of primer ,cleaning/cutting of nearby grass bushes all as specified and as directed.
10Disconnecting LT supply and taking out defective LT ACB of cap 400 to 1200Amps any make and rating and servicing by cleaning the fix and moving parts ,removing dust particle by using high speed blower applying greese/jelly to moving mechanism and moving parts, tightening complete.
11Supply and fixing in replacement of adjustable thermal and fixed magnetic release 63 Amps 4 PoleMCCB Breaking capacity Icu 10KA all as specified and directed.
12Supply and fixing in replacement of adjustable thermal and fixed magnetic release 100 Amps 4 PoleMCCB Breaking capacity Icu 10KA all as specified and directed.
13Supply and fixing in replacement of adjustable thermal and fixed magnetic release 125 Amps 4 PoleMCCB Breaking capacity Icu 16KA all as specified and directed.
14Supply and fixing in replacement of adjustable thermal and fixed magnetic release 250 Amps 4 PoleMCCB Breaking capacity Icu 36KA all as specified and directed.
15Supply and fixing in replacement of adjustable thermal and fixed magnetic release 160 Amps 4 PoleMCCB Breaking capacity Icu 35/36KA all as specified and directed.
16Supply and fixing in replacement of adjustable thermal and fixed magnetic release 400 Amps 4 PoleMCCB Breaking capacity Icu 35/36 KA all as specified and directed.
17M&L for Straight through / endjoints heat shrinkable for XLPE/PVC insulated and sheathed aluminium conductor under ground cable 1100 Volts 3.5/ 4 core 06 sqmm to 16 sqmm and testing after jointing complete all as specified and as directed.
18All as per item No. 17here-in-before but for cable 3.5/4 core 25 sqmm to 50 sqmm
19All as per item No. 17here-in-before but for cable 3.5/4 core 70 sqmm to 120 Sqmm
20All as per item No. 17here-in-before but for cable 3.5/4 core 150 sqmm to 185 Sqmm
21Supply only 25 mt long 2.5 cm wide and at least 0.125mm wall thickness PVC tape of good quality all as specified and directed.
22Material and labour for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to GI strip 32mm X 6 mm main earthing lead by means of galvanized bolts, nuts and washers all as shown in electrical plate no 5 of MES Schedule Part-I (1991)& including adequate quantity of charcoal dust and common salt all around earth plate, PCC (1:3:6) type C-1 (using 20mm graded black trap/granite/Basalt stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, pre cast RCC (1:2:4)type B-1 (using 20mm graded black trap/granite/Basalt stone aggregate)40mm thick cover reinforced with 8mm dia TMT bars 3 Nos both way with 12mm dia round bar handle, GI medium grade watering pipe 20 mm dia with funnel and wire mesh,and 40 mm dia GI medium grade earth lead protection pipe, complete all as specified and directed. NOTE : Earth strip and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item and additional earth strip/protection pipe etc. if any required at site shall bemeasured and paid for separately under appropriate item of Schedule `A’
23Cutting the worn out/unserviceable lugs from the cables upto 50 Sqmm size with and including supplying and fixing lugs after cutting the worn out /faulty cable end fromHT/LT side of transformer /LT pillar/panel box including necessary earth work for taking out the cable from loop, returning fillingetc and providing aluminium lugs lead including crimping with crimping tools in the existing LT cable and making necessary connections to make it functional complete all asspecified and as directed.
24Cutting the worn out/unserviceable lugs from the cables om 70 Sqmmsize with and including supplying and fixing lugs after cutting the worn out /faulty cable end fromHT/LT side of transformer /LT pillar/panel box including necessary earth work for taking out the cable from loop, returning fillingetc and providing aluminium lugs lead including crimping with crimping tools in the existing LT cable and making necessary connections to make it functional complete all asspecified and as directed.
25Cutting the worn out/unserviceable lugs from the cables 95 Sqmm size with and including supplying and fixing lugs after cutting the worn out /faulty cable end fromHT/LT side of transformer /LT pillar/panel box including necessary earth work for taking out the cable from loop, returning fillingetc and providing aluminium lugs lead including crimping with crimping tools in the existing LT cable and making necessary connections to make it functional complete all asspecified and as directed.
26Cutting the worn out/unserviceable lugs from the cables 120 Sqmm size with and including supplying and fixing lugs after cutting the worn out /faulty cable end fromHT/LT side of transformer /LT pillar/panel box including necessary earth work for taking out the cable from loop, returning fillingetc and providing aluminium lugs lead including crimping with crimping tools in the existing LT cable and making necessary connections to make it functional complete all asspecified and as directed.
27Cutting the worn out/unserviceable lugs from the cables150 Sqmm size with and including supplying and fixing lugs after cutting the worn out /faulty cable end fromHT/LT side of transformer /LT pillar/panel box including necessary earth work for taking out the cable from loop, returning fillingetc and providing aluminium lugs lead including crimping with crimping tools in the existing LT cable and making necessary connections to make it functional complete all asspecified and as directed.
28Cutting the worn out/unserviceable lugs from the cables185 Sqmm size with and including supplying and fixing lugs after cutting the worn out /faulty cable end fromHT/LT side of transformer /LT pillar/panel box including necessary earth work for taking out the cable from loop, returning fillingetc and providing aluminium lugs lead including crimping with crimping tools in the existing LT cable and making necessary connections to make it functional complete all asspecified and as directed.
29Cutting the worn out/unserviceable lugs from the cables from 240 Sqmm to 300 Sqmm size with and including supplying and fixing lugs after cutting the worn out /faulty cable end fromHT/LT side of transformer /LT pillar/panel box including necessary earth work for taking out the cable from loop, returning fillingetc and providing aluminium lugs lead including crimping with crimping tools in the existing LT cable and making necessary connections to make it functional complete all asspecified and as directed.
30M&L for replacement of 4 pole isolator 63 Amps complete all as specified and directed by Engr-in-charge.
31M&L for replacement of 4 pole isolator 100 Amps complete all as specified and directed by Engr-in-charge.
32M&L for CRCA mild steel sheet of size 2 mm thicksuitable for 3 phase 415 Volts 50 Hz complete painted with powder coated in siemens grey shade 7035 all as approved byEngr-in-charge for LT feeder enclosure of desired shape and size directed by Enr-in-charge of existing LT feeder panel double/single door type as directed with all fastening and fabrication element required at site complete.
33Supply and fixing in replacement of Voltmeter of size 96 x 96 having range 0-600V digital type including taking out old unsv complete all as specified and directed by Engr-in-charge.
34Supply and fixing in replacement of Ammeter of size 96 x 96 having range 0-250A digital type including taking out old unsv complete all as specified and directed by Engr-in-charge.
35Supply and fixing in replacement of VAF meter of size 96 x 96 digital type including taking out old unsv complete all as specified and directed by Engr-in-charge.
36Supply and fixing in replacement of Indicator lamp suitable for LT panel as standard colour (R,Y,B) including taking out old unsv complete all as specified and directed by Engr-in-charge.
37Supply and fixing in replacement of lock round type suitable for LT panel as standard including taking out old unsv complete all as specified and directed by Engr-in-charge.
38Supply and fixing in replacement of selector switch suitable for LT panel as standard including taking out old unsv complete all as specified and directed by Engr-in-charge.
39Supply and fixing in replacement of Danger notice plate having conventional skull and bone structure with red paint on sheet metal having thickness not less than 2 mm.suitable for LT panel as standard including taking out old unsv complete all as specified and directed by Engr-in-charge.
40M&L for replacement of heavy duty gas filled capacitor 440V, 3 phase, 50 Hz of capacity 25 KVAr including taking down old unsv capacitor complete all as specified and directed by Engr-in-charge.
41M&L for replacement of heavy duty gas filled capacitor 440V, 3 phase, 50 Hz of capacity 15 KVAr including taking down old unsv capacitor complete all as specified and directed by Engr-in-charge.
42M&L for replacement of heavy duty gas filled capacitor 440V, 3 phase, 50 Hz of capacity 10 KVAr including taking down old unsv capacitor complete all as specified and directed by Engr-in-charge.
43M&L for replacement of heavy duty gas filled capacitor 440V, 3 phase, 50 Hz of capacity 5 KVAr including taking down old unsv capacitor complete all as specified and directed by Engr-in-charge.
44M&L for replacement of heavy duty gas filled capacitor 440V, 3 phase, 50 Hz of capacity 3 KVAr including taking down old unsv capacitor complete all as specified and directed by Engr-in-charge.
45M&L for replacement of reactor for APFC panel440V, 3 phase, 50 Hz of capacity 25 KVAr reactor 7% including taking down old unsv reactor complete all as specified and directed by Engr-in-charge.
46M&L for replacement of Tempra pro P17 IP 66/67 panel mounted industrial socket inclined output of 63 A, 3P+N+E, 380/415V AC including taking down old unsv socket complete all as specified and directed by Engr-in-charge.
47M&L for replacement of Tempra pro P17 IP44 panel mounted industrial socket inclined output of 32 A, 2P+E, 200/250V AC including taking down old unsv socket complete all as specified and directed by Engr-in-charge.
48S&F in replacement MCB SP 5 to 32 Amps,240 volts curve "B",breaking capacity 10KA including taking down old unsv complete all as specified by Engr-in-charge.
49S&F in replacement MCB DP 20 Amps,240 volts curve "C",breaking capacity 10KA,including taking down old unsv complete all as specified by Engr-in-charge.
50Excavation in trenches in soft/loose soil not exc 1.50 mtrs wide and not exc. 1.5 mtr deep and getting out for taking out/laying cable pole &stay etc complete all as specified and directed by Engineer-in-Charge.
51Returning, filling in, including spreading levelling, watering and well ramming in layers not exc. 25 cm thickcomplete all as specified and directed by Engineer-in-Charge.
52Removal of excavated surplus soil to a distance not exc. 50 mtr away and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-Charge.
53M&L for sand cushioning to under ground cable provided with layer of sand (8cm deep before laying the cable and 15 cm deep after laying the cable ie total 23 cm and after punning down sand cushioning will be 18 cm complete all as specified and directed by Engineer-in-Charge. Note : 18 cm thick only will be considered for pryment purpose.
54Material labour for common burnt clay bricks, sub class "B" grade laid in trenches for protection of UG cables perpendicular to the direction of the cables complete all as specified and as directed by Engr-in-Charge
55Supplying, laying, jointing, testing and commissioning under ground XLPELT electric cable1100 Volts grade, heavy duty,PVC insulatedand sheathed armoued electric power cable with stranded aluminium conductor, of cross sectional area 50 Sqmm 4 core conforming to IS- 7098 (Part I) 1988 as in trenches over brick and sand cushioning or along the wall/pole through pipe etc served with an inner sheathing of PVC tape and overall PVC sheathed armoured with galvanized steel wire or tape including taking down/out of old cable as existing on site complete all as specified and as directed.
56Supplying, laying, jointing, testing and commissioning under ground XLPELT electric cable1100 Volts grade, heavy duty,PVC insulatedand sheathed armoued electric power cable with stranded aluminium conductor, of cross sectional area 70 Sqmm 3.5 core conforming to IS- 7098 (Part I) 1988 as in trenches over brick and sand cushioning or along the wall/pole through pipe etc served with an inner sheathing of PVC tape and overall PVC sheathed armoured with galvanized steel wire or tape including taking down/out of old cable as existing on site complete all as specified and as directed.
57Supplying, laying, jointing, testing and commissioning under ground XLPELT electric cable1100 Volts grade, heavy duty,PVC insulatedand sheathed armoued electric power cable with stranded aluminium conductor, of cross sectional area 95 Sqmm 3.5 core conforming to IS- 7098 (Part I) 1988 as in trenches over brick and sand cushioning or along the wall/pole through pipe etc served with an inner sheathing of PVC tape and overall PVC sheathed armoured with galvanized steel wire or tapecomplete all as specified and as directed.
58Supplying, laying, jointing, testing and commissioning under ground XLPELT electric cable1100 Volts grade, heavy duty,PVC insulatedand sheathed armoued electric power cable with stranded aluminium conductor, of cross sectional area 120 Sqmm 3.5 core conforming to IS- 7098 (Part I) 1988 as in trenches over brick and sand cushioning or along the wall/pole through pipe etc served with an inner sheathing of PVC tape and overall PVC sheathed armoured with galvanized steel wire or tape including taking out old unsv cable complete all as specified and as directed.
59Supplying, laying, jointing, testing and commissioning under ground XLPELT electric cable1100 Volts grade, heavy duty,PVC insulatedand sheathed armoued electric power cable with stranded aluminium conductor, of cross sectional area 185 Sqmm 3.5 core conforming to IS- 7098 (Part I) 1988 as in trenches over brick and sand cushioning or along the wall/pole through pipe etc served with an inner sheathing of PVC tape and overall PVC sheathed armoured with galvanized steel wire or tape including taking out old unsv cablecomplete all as specified and as directed. Note for srl No 55 to 59 :-Excavation and earth work, GI pipe,brick and sand cushioning or cable protection cover shall be measured and paid separately.