}

Tender For Eor To Quarter No. D-Ii-89 At Iti Campus, Pusa, New Delhi. (Sh : Electrical Work). -Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed, Delhi-Delhi

Public Works Department has published Tender For Eor To Quarter No. D-Ii-89 At Iti Campus, Pusa, New Delhi. (Sh : Electrical Work). -Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed. Submission Date for this Tender is 09-02-2023. Couplers Tenders in Delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

36044221
Tender For Eor To Quarter No. D-Ii-89 At Iti Campus, Pusa, New Delhi. (Sh : Electrical Work). -Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed
Open Tender
Indian
Delhi
Delhi
09-02-2023

Tender Details

Tender For Eor To Quarter No. D-Ii-89 At Iti Campus, Pusa, New Delhi. ( Sh : Electrical Work ) . - Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. 2 Group-B 3 Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Steel Conduit As Required. 4 2 X 1.5 Sq. Mm + 1 X 1.5 Sq. Mm Earth Wire 5 2 X 4 Sq. Mm + 1 X 4 Sq. Mm Earth Wire 6 4 X 4 Sq. Mm + 2 X 4 Sq. Mm Earth Wire 7 2 X 6 Sq. Mm + 1 X 6 Sq. Mm Earth Wire 8 Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. 9 3 X 1.5 Sq. Mm 10 3 X 4 Sq. Mm 11 6 X 4 Sq. Mm 12 3 X 6 Sq. Mm 13 Supplying And Fixing Of Following Sizes Of Steel Conduit Along With Accessories In Surface / Recess Including Painting In Case Of Surface Conduit, Or Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. 14 20 Mm 15 25 Mm 16 32 Mm 17 Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. 18 25 Mm 19 Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 20 5 / 6 A Switch 21 3 Pin 5 / 6 A Socket Outlet 22 15 / 16 A Switch 23 6 Pin 15 / 16 A Socket Outlet 24 Telephone Socket Outlet 25 Tv Antenna Socket Outlet 26 Bell Push 27 Supplying & Fixing Suitable Size Gi Box Wih Modular Plate And Cover In Front On Surface Or In Recess Including Providing And Fixing 25 A Modular Socket Outlet And 25 A Modular Sp Mcb, “C” Curve Including Connections, Painting Etc. As Required. ( For Ac & Gyser ) 28 Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) 29 6 Way, Double Door 30 Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) 31 16 Way, Double Door 32 Supplying And Fixing Following Way, Horizontal Type Three Pole And Neutral, Sheet Steel, Mcb Distribution Board, 415 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) 33 8 Way ( 4 + 24 ) , Double Door 34 Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, “C” Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 35 Single Pole 36 Supplying And Fixing Following Rating, Double Pole, 240 V, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required 37 63 A 38 Supplying And Fixing Following Rating, Double Pole, ( Single Phase And Neutral ) , 240 V, Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 39 63 A 40 Supplying And Fixing Following Rating, Double Pole, 240 V, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 41 40 A 42 Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required. 43 1 Or 2Module ( 75 Mmx75 Mm ) 44 3 Module ( 100 Mmx75 Mm ) 45 6 Module ( 200 Mmx75 Mm ) 46 8 Module ( 125 Mmx125 Mm ) 47 Suppying & Fixing 2 Modules Stepped Type Electronic Fan Regulators In The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plates Etc As Required. 48 Supplying And Drawing Following Pair 0.5 Mm Dia Frls Pvc Insulated Annealed Copper Conductor, Unarmored Telephone Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. 49 1 Pair 50 Supplying And Drawing Co-Axial Tv Cable Rg-6 Grade, 0.7 Mm Solid Copper Conductor Pe Insulated, Shielded With Fine Tinned Copper Braid And Protected With Pvc Sheath In The Existing Surface / Recessed Steel / Pvc Conduit As Required. 51 Supplying Installation, Testing And Commissioning Of 1200 Mm Sweep Anti Dust Technology Based Ceiling Fan With Copper Winding Including Wiring The Down Rods Of Standard Length ( Upto 30 Cm ) With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor, Single Core Cable, Complete Etc. As Required. 52 Supplying Installation, Testing And Commissioning Of 1200 Mm Sweep Ceiling Fan With Copper Binding Including Wiring The Down Rods Of Standard Length ( Upto 30 Cm ) With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor, Single Core Cable I / C Credit For Old Dismantled Material Etc. Complete As Required 53 Supplying, Installation, Testing And Commissioning Of Following Size Heavy Duty Exhaust Fan Of 300 Mm Sweep 900 Rpm Single Phase, In The Existing Opening I / C Louver Shutter Making Good The Damage, Connection, Testing, Commissioning Etc. As Required. 54 Supplying Installation, Testing And Commissioning Of Ip 65 Surface Mounted Led Bulkhead Type Fittingfor Having Minimum System Lumens 1000 & System Efficacy 80 Lumens / Watt In 5000-6000 K Cct Including Mounting On Surface With Help Of Ms Clamps Etc Including Connection , Earthing Etc. As Reqd. 55 Supplying, Installation, Testing & Commissioning Of Surface Typewall Mounted Integrated 4 Feet Ledfitting With Aluminium Housing For Having Minimum System Lumens 2000 & System Efficacy 100 Lumens / Watt Self Ballastedwith Pc Diffuser Having, Power Factor Of =0.95, Cri Of =80%, Thd =10%, Cct 4000- 6600K ( As Required ) , Suitable For 230 V, 50 Hz, 1-¢ Ac Supply I / C Fixing On Wall / Ceiling, Earthingetc. As Required. 56 Supplying, Installation, Testing & Commissioning Of Surface Typewall Mounted Integrated 4 Feet Ledfitting With Aluminium Housing For Having Minimum System Lumens 3600 & System Efficacy 100 Lumens / Watt, Self Ballastedwith Pc Diffuser Having, Power Factor Of =0.95, Cri Of =80%, Thd =10%, Cct 4000- 6600K ( As Required ) , Suitable For 230 V, 50 Hz, 1-¢ Ac Supply I / C Fixing On Wall / Ceiling, Earthingetc. As Required. 57 Supplying, Installation, Testing & Commissioning Of Decorative, Single Bracket, Wall Mounting, Ss Finish Fixture With Opal Glass Diffuser 6 / 10 Watt Led Bulb With 3000K / 5600 - 6000L ( Cct ) For Direct Lighting I / C Wiring And Making Connections With 1.5Sq.Mm. Pvc Insulated Frls, Copper Conductor, Single Core Cable Including Loop Earthing With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor, Single Core Cable Complete Etc. As Required. 58 Supplying , Installation & Testing & Commissioning Of Ventilation Fan 250 Mm With Suitable Size Louver Complete With Frame In The Existing Opening, Including Making The Hole To Suit The Size Of Above Fan And Making Good The Damage, Connection, Testing, Commissioning Etc. As Required. 59 Supplying & Fixing Of Electronic Ding Dong Door Bell Suitable For Single Phase 230V I / C Connections With 1.5 Sqmm Copper Conductor Cable, Testing & Commissioning Etc Complete As Reqd. 60 Supplying And Laying Of One Number Pvc Insulated And Pvc Sheated / Xlpe Aluminium Conductor Armoured Power Cable Of 1.1 Kv Grade Of Following Size In Existing Hdpe Pipe Etc As Reqd. 61 3 X 10 Sqmm 62 Supplying And Laying Of Following Size Dwc Hdpe Pipe Isi Marked Along With All Accessories Like Socket, Bend, Couplers Etc. Conforming To Is 14930, Part Ii Complete With Fitting And Cutting, Jointing Etc..Direct In Ground ( 75 Cm Below Ground Level ) Including Excavation And Refilling The Trench But Excluding Sand Cushioning And Protective Covering Etc., Complete As Required. 63 A ) 63 Mm Dia ( Od-63 Mm & Id-51 Mm Nominal ) 64 Supplying & Laying And Fixing Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Armoured Power Cable Of 1.1 Kv Grade Of Following Size On Wall Surface As Required. 65 3 X 10 Sq.Mm ( On Surface ) 66 Supplying And Fixing Call Bell / Buzzer Suitable For Single Phase, 230 V, Complete As Required. 67 Supply, Installation, Testing And Commissioning Of Upward And Downward Wall Mounted Fixture / Wall Sconces Lights Having Space Saving And Eye Captivations, Soothing Brightness, Giving An Elegent And Charging To Home And Suitable Size Holder For 2 X 6 Watt Led Light Bulb Fittings Decover Having High Efficiencies I / C Base Arrangement For Fixing On Wall And Connections Etc Complete As Required. 68 Supplying / Replacement , Installation, Testing & Commissioning Of Having Minimum System Lumens 1200 & System Efficacy 100 Lumens / Watt, Led Bollard Light Fittings Are Made Of Cast Alum With Small Windsor Fixture And Opal Diffuser For Glare Free Ligghting With Ip 65 Ik 10 Protection, 5700K, Cct- 3000K Including Suitable Foundation With Complete Mounting Arrangement I / C All Accessories / Attachments, Making Connections Etc. As Reqd I / C Credit For Old Material As And Where Basis Etc As Reqd. As Per Direction Of Enginer-In-Charge. 69 Supplying, Installation, Testing & Commissioning Ofhaving Minimum System Lumens 1500 & System Efficacy 100 Lumens / Watt, Round Shape Led Ground Burrial Light Pressure Die Cast Aluminium Housing, Powder Coated With Weather Proof Gasket Ensuring Ip 68 Protection, Heat Resistant Toughend Glass, Optics- Wide Beam With Anodised Aluminium Reflectors, Cct 2700K-6500K I / C All Accessories / Attachments, Making Connections, Providing And Fixing Suitable Base For Light Fixture Etc. As Reqd. As Per Direction Of Enginer-In-Charge. 70 Supplying Installation, Testing & Commissioning Of Led Post Top Fitting Of Having Minimum System Lumens 4500 & System Efficacy 100 Lumens / Watt, Thd =10%, Power Factor=0.95, Cri=80, Ip 66 Made Out Of High Pressure Die Cast Aluminium Housing With Pre-Wired Gear Tray With Leds And Driver, Supply Directly I / C Connections With 1.5 Sqmm., Pvc Insulated, Frls Copper Conductor, Single Core Cable On The Existing Pole Complete With Making Suitable Arrangement To Fix On The Existing Pole Using Reducer / Enlarger If Required, Testing And Commissioning Etc. As Required. 71 Supplying And Drawing Following Sizes Of Pvc Insulated Copper Conductor Multicore Cable In The Existingpoles And Bracket From Cable Termination Connector To The Fitting I / C Providing Suitable Copper Lugs Connections Etc. As Reqd. ( A ) 3Core X 2.5 Sq. Mm 72 Supplying, Installation, Testing & Commissioning Of Flood Light Fitting Led Made Of Pressure Die Cast Aluminum With High Power Ledhaving Minimum System Lumens 10800 & System Efficacy 120 Lumens / Watt, Cct = 3000-6500K, Cri=70, Surge Protection Device = 4Kv, Secondary Optics With Lens, Ip 66 Housing, Electronic Driver, On The Existing Pole / Wallincludingconnection Etc. Complete As Required. 73 Sitc Of Weather Proof Pole Box Made Out Of Hot Moulded Smc Sheet With Clamp / Fastner Neutral Link Strip, Gland Thimble And 1 No. 6 Amps Spmcb Complete With Inter Connection With Copper Wire, Earthing ( Box Size - 300 Mm X 200 Mm X 105 Mm ) 74 Supplying, Installation, Testing & Commissioning Of Following Wattage Street Light Led Fittings Having Minimum System Lumens Output Should More Than10800 & System Efficacy 120 Lumens / Watt, Ip66 Protected, Body Made Out Of Pressure Die Cast Aluminium For Better Thermal Management, Power Factor=0.95, Thd=10%, Cri=70% & Cct 4000-6500 °Ki / C Fixing On Existing Pole / Bracket Making Connection Etc Complete As Required. 75 Supplying , Installation& Testing & Commissioning Of 400 Mm Wall Fan Oscillating Type With Speed Regulator With String, Aerodynamically Designed & Balanced Blades Complete With All Accessories I / C Connection, Testing, Commissioning Etc. As Required. 76 Earthing With G.I. Earth Pipe 4.5 Meter Long, 40 Mm Dia Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Etc. With Charcoal / Coke And Salt As Required. 77 Providing And Laying Earth Connection From Earth Electrode With 6 Swg Dia G.I. Wire In 15 Mm Dia G.I. Pipe From Earth Electrode Including Connection With G.I. Thimble Excavation And Re-Filling As Required. 78 Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In Recess For Loop Earthing Along With Existing Surface / Recessed Conduit / Submain Wiring / Cable As Required. 79 Supplying, Installation, Testing And Commissioning Of Decorative Cast Iron Based With Gi Tube Pole Of Height 4 M Above The Ground Level Powder Coated With Die Cast Aluminium Embellishments, Provided With Oval / Rectangle Shape Service Window With Sleeve Type Window Cover The Lower Part Of The Pole With Proper Stengthening To The Cutout Of The Door Opening And Base Plate Duly Welded And Fixed At Bottom Of Pole At Concrete Pedestal. Base Plate Is Fixed With Cast Iron Having 2 Part One Part Height Is 625Mm From Base Plat Ground Level & Second Part 90-100 Mm Dia, ( Thickness Minimum 4 Mm With 32 Amps Heavy Duty Connector Shall Be Inbuilt Into The Pole ( A ) Heavy Duty 4 Way Connector And 6 Amp Mcb ( B ) 50 Mm Diameter Dwc Pipe For Each Cable Entry / Exist Pipe Length Is Upto 3.5 Mtr. ( C ) Wiring Upto The Light Fixture From The Junction Box Using 3-Core X 1.5 Sqmm Flexible Isi Marked Copper Wires. 80 Supplying & Fixing Of 4 Nos. 20Mm Dia X 450Mm Longh Gi Foundation Bolt ( En8 Grade ) With Nuts, Washer Including 2 Nos. Template Of 4Mm Thick Size 240Mm X 240Mm With 4 Nos. 20Mm Dia Holes, To Match With Pcd Of Pole Base Plate As Reqd. ( For 4Mtr. Pole ) 81 Providing And Laying In Position 1:2:4 Reinforced Cement Concrete Foundation Of Size 450 Mm. ( L ) X 450 Mm. Wide And 800 Mm. Deep I / C Excavation Of Earth, Providing Cutting, Bending And Placing In Position, Reinforcement Of Cold Twisted Bars Of 12 Mm. Dia- 860Mm Long ( Approx ) - 8 Nos. And 4 Nos. Reinforcement Ring Of Cold Twisted Bar Of 8Mm Dia - 1800Mm ( Ns ) Equally Distanced In Length Of Vertical Bar As Reqd. With Positioning Of Foundation Bolts ( As Per Item Below ) And Providing 40 Mm. ( O.D ) Dwc, Hdpe Pipe Of 0.3Mtrs 82 Sitc Of Surface / Recess Mounted Round / Square Led Downlighterhaving Minimum System Lumens Output 1500 & System Efficacy 100 Lumens / Watt And Colour Temperture Of 4000-6600 Kelvin, Cri =80%, Having Power Factor=0.95, Thd =10%Etc. Complete As Reqd. 83 Credit / Buyback I / C Dismantling For Old Dismantle Material As & Where Basis Etc Complete As Reqd. 84 Old Assorted Copper / Aluminium Wire 85 Old Assorted Light Fitting 86 Old Assorted 5 / 6Amp Modular / Piano Type Switch & Socket 87 Old Assorted 15 / 16Amp Modular / Piano Type Switch & Socket 88 Old Assorted 1200 Ceiling Fan 89 Old Assorted 300Mm Exhaust Fan 90 Old Assorted Bollard Fitting 91 Old Assorted Post Top Fitting 92 Old Assorted Size Steel Conduit

Key Value

Document Fees
Refer document
EMD
INR 24106.0 /-
Tender Value
INR 12.05 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail