Tender Details

Purchase Of Equipments For Bt Dept , Equipments , Multi Gas Analiser:The System Should Be Suitable For Simultaneously Monitoring The Percentage Composition Of H2, Ch4, O2 And Co2present In The Exit / Vent Gas From 3 L And 7 L Laboratory Bioreactors / Fermenters. Range Of Measurements: 0-100 % ( For All Gases ) Resolution: 0.1 % ( For All Gases ) Detectors: Non-Dispersive Infrared ( For Co2 And Ch4 ) , Electrochemical ( For Oxygen ) , Thermal Conductivity ( For H2 ) Sample Injection Options: Gas Sample Should Be Able To Flow Freely ( By Diffusion ) At High Gas Flow Rates, And Should Be Pressurized ( Using A Pump ) At Low Flow Rates. Suitable Pump Should Be Supplied With The System. Gas Connections: ¼ Inches Swagelok Type ( Spare 1 / 8 Inches Connectors Should Also Be Supplied ) Sample Conditioning Elements ( Cooling Coils, Filters, Pressure Regulators, Safety Valves, By-Pass Valves Etc. ) Should Be Supplied In Dedicated Housings. Analyzer Output: Led Digital Display Power Supply: 220 V Ac Flow Controls And Flow Indication Should Be Provided In An Integrated Configuration For Online Continuous Analysis. Data Acquisition System ( Without Pc ) : A Single Channel Data Station For Connecting With Pc ( Windows 10, I3 Processor, 8 Gb Ram ) Along With Suitable Hardware And Compatible Software Should Be Provided. Trends And Text Data Should Be Stored And Viewed On Computer And Must Be Generated In Excel Sheet. The Entire Unit Should Be Enclosed Within A Dust-Proof Cover And Must Be Suited For Tabletop Applications. , Single Channel Peristaltic Pump Minimum Speed: 0.1 Rpm, Maximum Speed: 300 Rpm Flow Range: 0.004 To 315 Ml / Min, Speed Control ( Repeatability ) : ±0.1 % Reversible Motor, Single-Channel Pump Head , Tubing Sizes Accepted:L / S / 13, 14, 16 And 25 ( Depending On The Flow Rates ) Power Supply: 0.2 Amps, 50 Hz, 230 Vac, Bench Top Power Supply With Iec320 / Cee22 Socket Icon-Driven Menu For Quick, Intuitive Programming And Setup Open-Head Sensor Stops The Drive When The Pump Head Is Opened Housing Material: Abs Plastic And Aluminium , Mass Flow Meter Flow Range:0-5 Slpm ( Full Scale ) , Display: Backlit Monochrome Lcd Screen, Multivariate Measurements: Mass Flow, Volumetric Flow, Absolute Pressure, And Temperature, 8 Pin Mini-Din Electrical Connector, User Customizable Gas Presets, Rs-232 Data Communication, 2.1 Mm Barrel Power Jack, Primary 0-10 Volt Output Of Mass Flow, Power Requirements: 230 V Ac, 50 Hz, 1 / 8 Inch Female Npt Process Connections, Approx. Pressure Drop At Default Body Full Scale ( Assuming Air, Venting To Atmosphere ) : 1 Psi, 100:1 Turndown Ratio, Accuracy Specification: ± ( 0.2% Of Full Scale + 0.8% Of Reading ) , Calibration Certificate To Be Provided, Rohs Compliant 6’ Single Ended Mini-Din Cable, 8 Conductor , Bio Reactor And Accessories:-Glass Vessels ( Autoclavable ) Of Two Different Capacities ( 3 L And 7 L ) Interchangeable With A Single ( Common ) Control Unit. 3 L Glass Vessel: Maximum Working Volume: 2.7 Litres; Minimum Working Volume: 0.5 Litres, 7 L Glass Vessel: Maximum Working Volume: 5.4 Litres; Minimum Working Volume: 1.5 Litres, Vessel Dimensions: 3 L Vessel: Inner Diameter: 130 Mm; Inner Height: 240 Mm; Autoclave Dimensions ( Wxh ) : F235mm X 435 Mm ( Approx. ) 7 L Vessel: Inner Diameter: 160 Mm; Inner Height: 350 Mm; Autoclave Dimensions ( Wxh ) : F265 Mm X 645 Mm ( Approx. ) Drive System:Direct Drive, Lip Sealed Or Magnetically Coupled Stirrer Speed: Standard Range 10 – 1250 Rpm ( 2000 Rpm Motor Is Preferred ) Stirrer Speed: Standard Range 10 – 1250 Rpm ( 2000 Rpm Motor Is Preferred ) Ch Vessel Capacity ( Impeller Diameter = 1 / 3 ( Inner Diameter Of The Vessel ) Baffles: 3-4 Vertical Baffles ( Removable ) On Head Plate With Sizes Appropriate For Each Vessel Capacity. Gas Sparger: Porous Sparger Or L-Type Exhaust Gas: Water Cooled Exhaust Gas Condenser Sampling: Height Adjustable Sample Pipe With Sampling System. Two Sampling Pipes With Internal Diameter 1.7 Mm And 4 Mm To Be Provided For Each Vessel. Draining: Through Drain Pipe, Additions:Triple And Single Inlet Ports , Ph Measurement: 12 Mm Glass Electrode Ph Sensor ( Of Separate Lengths Suited For Each Vessel Capacity ) Ph Control: Via Acid Pump In Combination With Alkali Pump Dissolved Oxygen Measurement: 12 Mm Polarographic Do Sensor ( Of Separate Lengths Suited For Each Vessel Capacity ) Do Control: Via A Combination Of N2, Air / O2 Sparging ( Using Mfc ) And By Agitation, Temperature Measurement: Pt-100 Sensor In Thermowell In Top Plate ( Of Separate Lengths Suited For Each Vessel Capacity ) Temperature Control: By Circulating Hot Or Cold Water Through Glass Jackets With The Aid Of A Thermocirculator ( Or ) Using Peltier Heating And Cooling Module , Foam Measurement: Height Adjustable Conductivity-Based Foam Sensor , Foam Control: Anti-Foam Addition Pump ( Peristaltic, Programmable Type ) , Level Measurement: Height Adjustable Conductivity-Based Level Sensor , Level Control: Peristaltic Pump For Liquid Addition And / Or Removal Inlets:Septum, Chemostat Tube And Liquid Entry System Data Acquisition System ( Without Pc ) : Software ( Compatible With Windows 10 Operating System On Pc With Intel Core I3 Processor And 8 Gb Ram ) With Process Controller Functions, Customized Operator Interface, Display Feature For All Process And Set Point Values, Alarm And Event Logs, Different Access Levels, Online Recording Of All Set Points And Measurement Values, Trends And Text Data. Data Should Be Exportable To An Excel Sheet. Maintenance Kit: Should Include Spare Ph Electrodes, Do Probes, Membrane Kit For Do Sensors ( 12 Mm ) , Electrolyte For Do Sensor, Autoclavable Gas Filters ( 0.2 Microns, 0-40 L / Min ) , Plastic Hose Connections And Other Items Which Could Require Occasional Replacement By The User. An Operating Manual And Troubleshooting Guide Should Be Supplied With The Unit. An Extended Warranty For 3 Years Should Be Provided. , Multy Para Meter Water Quality Meter With Accessories Waterproof Handheld Device Which Should Enable Measurement Of Ph, Ion Concentration, Conductivity, Dissolved Oxygen ( Do ) , Salinity, Tds And Temperature. ? Number Of Parameters To Be Measured Concurrently: 3 ( Minimum ) ? Ph Range: -1.000 To 15.000 ( Minimum ) ? Ph Resolution And Accuracy: 0.1 / 0.01 / 0.001 Ph & ±0.002 Ph? No. Of Ph Calibration Points: 3 ( Minimum ) ? Mv Range: + / - 2000.00 Mv? Mv Resolution And Accuracy: 0.1 Mv & ±0.2 Mv? Ion Concentration Range: 0.001 To 19900? Ion Concentration Resolution And Accuracy: 2 Or 3 Digits & ±0.5% Fs ( Mono ) ; 1% Fs ( Div ) ? No. Of Ion Calibration Points: 3 ( Minimum ) ? Do Range: 0 To 90.00 Mg / L Or Ppm / 0 To 100 %? Do Resolution And Accuracy: 0.01 Mg / L Or Ppm / 0.1% ; ±0.2Mg / L / ±0.2%? Barometric Pressure Resolution And Accuracy: 450 To 825 Mmhg / 59.9 To109.9 Kpa & 0.1 Mmhg Or 0.1 Kpa? Conductivity Range: 0 To 500 Ms / Cm ? Conductivity Resolution And Accuracy: 0.05% Fs & ±1% Fs + 1 Lsd? Conductivity Cell Constant: 0.010 To 10.000 ? Tds Range: 0 To 500 Ppt.? Tds Resolution And Accuracy: 0.05% Fs & ±1% Fs +1 Lsd? Salinity Range: 0 To 80 Ppt ? Salinity Resolution And Accuracy: 0.05% Fs & ±1% Fs +1 Lsd? Temperature Range: -10.0 To 110.0 °C / 14.0 To 230.0 °F ( Meter ) ? Temperature Resolution And Accuracy: 0.1 °C / °F & ±0.5°C / 0.9°F?Temperaturecompensation:Automatic? Essential Features: Auto-Calibration; Data-Logging Options With Time / Dateindexed, Glp Compliance; Simultaneous Display And Measurement Of Atleast 4 Rameters;Calibration–Due Alarm; Ph Slope / Offset Display & Self-Diagnostics.? Memory: 500 Data Sets With Date / Time Stamping & Security Password Protection ? Output: Irda Wireless Communiations? Isplay: Multi-Data Back-Lit Dot Matrix? Power: 4 X 5&Quot;Aa&Quot; Alkaline Batteries Or 9 V Dc Adapter, 500 Ma? Should Be Supplied With A Warranty Of At Minimum 3 Years. , Ordinary Centrifuge? Centrifuge Design: Bench Top Maximum Rpm With No Load: ≪ 20000? Rpm Setting Accuracy: + / - 5% ? Type Of Motor: Brushless ( Without Carbons ) ? Type Of Lid Lock: Both Manual And Electronic ? Ambient Operating Temperature Range ( In Degree Celsius ) Andhumidity Range: 0 To 40 And Relative Humidity Is 15 To 80 % ? Rotor Imbalance Diagnostics And Automatic Stop If Required ? No Of Accelaration And Decelaration Profiles In Built For Rotor Speedwhile Automatic Braking: Programmable From 50 To 200 Seconds Ininterval Of 5 Seconds? Parameters To Be Displayed By The Digital Display: Rpm, Rcf, Settime, Run Time, Rotor Running Indication , Imbalancing If Any? Display Type: Lcd? Speed Controller: Microprocessor Controlled Pre Programmed Speedcontroller Which Can Control Rpm As Well As Rcf ? Configuration Of Rotor Supplied With Centrifuge Machine: Anglerotor? Rotor Feature With Reference To Autoclavability: Autoclavable Rotor@121 Degree Celsus? Type Of Tubes Which Can Be Used With Centrifuge Machine:Polypropylene Centrifuge Tubes And Glass Centrifuge Tubes? Size Of Rotor Supplied With Centrifuge: 24X15ml ( For Angle Rotor ) Rpm 6000? Maximum Rcf: 3650? Power Supply: 220V-240V 50 Hz , Butane Lamps ? Piezo Ignition? Max. Temperature: 1300?? Adjustable Flam ? Refillable Butane Tank? Ce Certification ? Max. Temperature: 1300? ? Fuel Tanker Capacity: 35 G ? Working Time: 60 Min ? Equipped With Safe Switch , Anaerobic Gas Pack Culture Systemwith Accessories ? Transparent Anaerobic Culture Jar Of 3.5 Litres Capacity Which Ismade Of Polycarbonate.? The Lid Of The Jar Should Be Made Of Aluminium Pressure Die Casting Fitted With Pressure Valve, Vacuum Valve, Safety Valve & Compound Pressurecum Vacuum Gauge, Three Finger Aluminium Clamp And Sealing &Quot;O&Quot; Ring And Air / Gas Chuck.? Accessories:? Petri Plate Carrier, Stainless Steel, For 10 Petri Dishes.? Test Tube Carrier, Stainless Steel.? Spares To Be Provided:? Anaerobic Indicator, Box Of 20 Tablets? Anaerobic Gas Pack, 10 Packets ( 5 Sachets In Each Packet ) ? Silicone Rings , Air Conditioners ( I ) ? Air Conditioner Type: Split ? Capacity: 1.5 Ton ? Approximate Coverage Area: 180 Sq.Ft. ? Installation Type: Wall Mount ? Cooling Technology: Multi-Adjustable Turbo Cooling ? Air Flow Volume: 550 Cfm ( Approx. ) ? Humidity Control Should Be Possible ? Equipped With Inverter Technology And Stabilizer Free Operation. ? Cooling Capacity: 5200 Watts / Hour ? Ambient Temperature ( Cooling / Heating ) : 50 Degree Celsius. ? Operating Voltage Range: 110-285 Volts ? Should Be Capable Of Low Voltage Start ? Compressor Type: Rotary-Bldc ? Refrigerant: R32 ? Air-Flow Type: Cross Flow ? Connecting Pipe Type: Copper ( 3 M Length ) ? Condenser Coil Type: Copper ? Evaporator Coil Type: Evaporator Fin ? Self-Diagnosis And Auto-Restart Functions ? Energy Efficiency Rating: 5 Star ? Plug Details: 1455 W, 230 V 50 Hz , Single Phase ? Warranty: 10 Years On Compressor, 2 Years On Condenser. , 5.2 Kva Invertor With Batteries? Inverter Capacity: 72 Volt, Capacity: 5200 Va, Max. Bulb Load: 4400 Watt ( Approx. ) ? Battery Capacity : Voltage - 12 Volt, Capacity - 150 Ah, Tall Tubularinverter Battery ? No. Of Batteries: 06 ? Key Features For Inverter :-Sine Wave Inverter, Intelligent Batterycharging Mechanism With Adaptive Battery Charging Controltechnology? Key Features For Battery : Highly Efficient And Ideal For Heavy Dutyapplication With Excellent Overcharge Tolerance, Superior Performance During Long And Frequent Power Cuts And Minimum Maintenance ? Running Load : 1 Desktop Pc, 20 Led Bulb 9W, 10 Led Tubelight24w, 8 Fans, 1 Fridge ( 250 Litre ) , 1 Ac ( 1.5 Tonne ) ? Safety :- Mcb For Protection From Input Main, Auto Over-Load Handling Capacity, Bypass Switch For Supplying Output Directly From Grid In Case Of Ups Fault

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 13-Feb-2023 Date Extension Date 21-02-2023
2 21-Feb-2023 Date Extensionnew Date 04-03-2023

Key Value

Document Fees
INR 1770 /-
EMD
INR 7500.0 /-
Tender Value
INR 40 Lakhs /-

BOQ Items

Name of Work: PURCHASEOF EQUIPMENTS FOR BT DEPT
Sl. No. Item Description
1EQUIPMENTS
2Multi Gas Analiser:The system should be suitable for simultaneously monitoring the percentage composition of H2, CH4, O2 and CO2present in the exit/vent gas from 3 L and 7 L laboratory bioreactors/fermenters. Range of measurements: 0-100 % (for all gases) Resolution: 0.1 % (for all gases) Detectors: Non-dispersive infrared (for CO2 and CH4), Electrochemical (for oxygen), Thermal conductivity (for H2) Sample injection options: Gas sample should be able to flow freely (by diffusion) at high gas flow rates, and should be pressurized (using a pump) at low flow rates. Suitable pump should be supplied with the system. Gas connections: ¼ inches Swagelok type (spare 1/8 inches connectors should also be supplied) Sample conditioning elements (cooling coils, filters, pressure regulators, safety valves, by-pass valves etc.) should be supplied in dedicated housings. Analyzer output: LED digital display Power supply: 220 V AC Flow Controls and flow Indication should be provided in an integrated configuration for online continuous analysis. Data acquisition system (without PC): A single channel data station for connecting with PC (Windows 10, i3 processor,8 GB RAM) along with suitable hardware and compatible software should be provided. Trends and text data should be stored and viewed on computer and must be generated in excel sheet. The entire unit should be enclosed within a dust-proof cover and must be suited for tabletop applications.
3Single channel peristaltic pump Minimum speed: 0.1 rpm, Maximum speed: 300 rpm Flow range: 0.004 to 315 ml/min, Speed control (repeatability): ±0.1 % Reversible motor, Single-channel pump head ,Tubing sizes accepted:L/S/13,14, 16 and 25 (depending on the flow rates) Power supply: 0.2 Amps, 50 Hz, 230 VAC, Bench top power supply with IEC320/CEE22 socket Icon-driven menu for quick, intuitive programming and setup Open-head sensor stops the drive when the pump head is opened Housing material: ABS plastic and aluminium
4Mass flow meter Flow range:0-5 SLPM (full scale),Display: Backlit monochrome LCD screen,Multivariate measurements: mass flow, volumetric flow, absolute pressure, and temperature,8 pin mini-DIN electrical connector, User customizable gas presets, RS-232 data communication,2.1 mm barrel power jack,Primary 0-10 volt output of mass flow,Power Requirements: 230 V AC, 50 Hz, 1/8 inch female NPT process connections,Approx. pressure drop at default body full scale (assuming air, venting to atmosphere): 1 Psi,100:1 Turndown ratio, Accuracy specification: ±(0.2% of full scale + 0.8% of reading), Calibration certificate to be provided,RoHS compliant 6’ Single ended mini-din cable, 8 conductor
5Bio Reactor and Accessories:-Glass vessels (autoclavable) of two different capacities (3 L and 7 L) interchangeable with a single (common) control unit. 3 L glass vessel: Maximum working volume: 2.7 litres; Minimum working volume: 0.5 litres,7 L glass vessel: Maximum working volume: 5.4 litres; Minimum working volume: 1.5 litres,Vessel dimensions: 3 L vessel: Inner diameter: 130 mm; Inner height: 240 mm; Autoclave dimensions (WxH): F235mm x 435 mm (approx.) 7 L vessel: Inner diameter: 160 mm; Inner height: 350 mm; Autoclave dimensions (WxH): F265 mm x 645 mm (approx.) Drive system:Direct drive, lip sealed or magnetically coupled Stirrer speed: Standard range 10 – 1250 rpm (2000 rpm motor is preferred) Stirrer speed: Standard range 10 – 1250 rpm (2000 rpm motor is preferred) ch vessel capacity (Impeller diameter = 1/3 (inner diameter of the vessel) Baffles: 3-4 vertical baffles (removable) on head plate with sizes appropriate for each vessel capacity. Gas sparger: Porous sparger or L-type Exhaust gas: Water cooled exhaust gas condenser Sampling: Height adjustable sample pipe with sampling system. Two sampling pipes with internal diameter 1.7 mm and 4 mm to be provided for each vessel. Draining: Through drain pipe,Additions:Triple and single inlet ports ,pH Measurement: 12 mm glass electrode pH sensor (of separate lengths suited for each vessel capacity) pH control: via acid pump in combination with alkali pump Dissolved oxygen Measurement: 12 mm polarographic DO sensor (of separate lengths suited for each vessel capacity) DO control: Via a combination of N2, Air/O2 sparging (using MFC) and by agitation,Temperature Measurement: Pt-100 sensor in thermowell in top plate (of separate lengths suited for each vessel capacity) Temperature control: By circulating hot or cold water through glass jackets with the aid of a thermocirculator (or)using Peltier heating and cooling module ,Foam measurement: Height adjustable conductivity-based foam sensor ,Foam control: Anti-foam addition pump (Peristaltic, programmable type) ,Level Measurement: Height adjustable conductivity-based level sensor ,Level control: Peristaltic pump for liquid addition and/or removal Inlets:Septum, chemostat tube and liquid entry system Data acquisition system (without PC): Software (compatible with Windows 10 operating system on PC with intel core i3 processor and 8 GB RAM) with process controller functions, customized operator interface, display feature for all process and set point values, alarm and event logs, different access levels, online recording of all set points and measurement values, trends and text data. Data should be exportable to an excel sheet. Maintenance kit: Should include Spare pH electrodes,DO probes, Membrane kit for DO sensors (12 mm), Electrolyte for DO sensor, Autoclavable gas filters (0.2 microns, 0-40 l/min), Plastic hose connections and other items which could require occasional replacement by the user. An operating manual and troubleshooting guide should be supplied with the unit. An extended warranty for 3 years should be provided.
6Multy Para Meter Water Quality Meter with accessories Waterproof handheld device which should enable measurement of pH, Ion concentration, conductivity, dissolved oxygen (DO), salinity, TDS and temperature. ? Number of parameters to be measured concurrently: 3 (Minimum) ? pH range: -1.000 to 15.000 (minimum) ? pH resolution and accuracy: 0.1/0.01/0.001 pH & ±0.002 pH? No. of pH calibration points: 3 (minimum) ? mV range: +/- 2000.00 mV? mV Resolution and accuracy: 0.1 mV & ±0.2 mV? Ion concentration range: 0.001 to 19900? Ion concentration resolution and accuracy: 2 or 3 digits & ±0.5% FS(mono); 1% FS (div)? No. of ion calibration points: 3 (Minimum)? DO range: 0 to 90.00 mg/L or ppm/ 0 to 100 %? DO resolution and accuracy: 0.01 mg/L or ppm / 0.1% ; ±0.2mg/L / ±0.2%? Barometric pressure resolution and accuracy: 450 to 825 mmHg / 59.9 to109.9 kPa & 0.1 mmHg or 0.1 kPa? Conductivity range: 0 to 500 mS/cm ? Conductivity resolution and accuracy: 0.05% FS & ±1% FS + 1 LSD? Conductivity cell constant: 0.010 to 10.000 ? TDS range: 0 to 500 ppt.? TDS resolution and accuracy: 0.05% FS & ±1% FS +1 LSD? Salinity range: 0 to 80 ppt ? Salinity resolution and accuracy: 0.05% FS & ±1% FS +1 LSD? Temperature range: -10.0 to 110.0 °C / 14.0 to 230.0 °F (Meter)? Temperature resolution and accuracy: 0.1 °C/°F & ±0.5°C/ 0.9°F?Temperaturecompensation:Automatic? Essential features: Auto-Calibration; Data-logging options with time/dateindexed, GLP compliance; Simultaneous Display and measurement of atleast 4 rameters;Calibration–due alarm; pH slope/offset display & Self-diagnostics.? Memory: 500 Data Sets with date/time stamping & security password protection ? Output: IrDA Wireless Communiations? isplay: Multi-data Back-lit dot matrix? Power: 4 X 5"AA" alkaline batteries or 9 V DC adapter, 500 mA? Should be supplied with a warranty of at minimum 3 years.
7Ordinary Centrifuge? Centrifuge design: Bench Top Maximum RPM with no load: < 20000? RPM setting accuracy: +/- 5% ? Type of Motor: Brushless(without carbons) ? Type of lid lock: Both Manual and Electronic ? Ambient operating Temperature range (in Degree Celsius) andHumidity Range: 0 to 40 and relative humidity is 15 to 80 % ? Rotor imbalance diagnostics and automatic stop if required ? No of accelaration and decelaration profiles in built for rotor speedwhile automatic braking: Programmable from 50 to 200 Seconds inInterval of 5 Seconds? Parameters to be displayed by the digital display: RPM,RCF,Settime,Run time,Rotor running indication ,imbalancing if any? Display type: LCD? Speed controller: Microprocessor controlled pre programmed speedcontroller which can control RPM as well as RCF ? Configuration of Rotor supplied with centrifuge machine: Anglerotor? Rotor Feature With Reference to Autoclavability: Autoclavable Rotor@121 Degree Celsus? Type of Tubes which can be used with centrifuge machine:Polypropylene Centrifuge tubes and Glass centrifuge tubes? Size of rotor supplied with centrifuge: 24x15ml(for angle rotor) RPM 6000? Maximum RCF: 3650? Power supply: 220V-240V 50 Hz
8Butane Lamps ? Piezo ignition? Max. temperature: 1300?? Adjustable flam ? Refillable butane tank? CE certification ? Max. temperature: 1300? ? Fuel tanker capacity: 35 g ? Working time: 60 min ? Equipped with safe switch
9Anaerobic Gas Pack Culture Systemwith accessories ? Transparent anaerobic Culture Jar of 3.5 litres capacity which ismade of Polycarbonate.? The lid of the jar should be made of Aluminium Pressure die casting fitted with Pressure valve, Vacuum valve, Safety valve & Compound Pressurecum vacuum gauge, three finger aluminium clamp and sealing "O" ring and Air/Gas chuck.? Accessories:? Petri Plate Carrier, Stainless steel, for 10 Petri Dishes.? Test Tube Carrier, Stainless Steel.? Spares to be provided:? Anaerobic Indicator, Box of 20 Tablets? Anaerobic Gas Pack, 10 packets (5 sachets in each packet) ? Silicone Rings
10Air Conditioners (I)? Air conditioner type: Split ? Capacity: 1.5 Ton ? Approximate coverage area: 180 sq.ft. ? Installation type: Wall mount ? Cooling technology: Multi-adjustable turbo cooling ? Air flow volume: 550 CFM (approx.) ? Humidity control should be possible ? Equipped with inverter technology and stabilizer free operation. ? Cooling capacity: 5200 watts/hour ? Ambient temperature (cooling/heating): 50 degree celsius. ? Operating voltage range: 110-285 volts ? Should be capable of low voltage start ? Compressor type: Rotary-BLDC ? Refrigerant: R32 ? Air-flow type: Cross flow ? Connecting pipe type: Copper (3 m length) ? Condenser coil type: Copper ? Evaporator coil type: Evaporator fin ? Self-diagnosis and auto-restart functions ? Energy efficiency rating: 5 star ? Plug details: 1455 W, 230 V 50 Hz , Single phase ? Warranty: 10 years on compressor, 2 years on condenser.
115.2 KVA Invertor with batteries? Inverter Capacity: 72 Volt, Capacity: 5200 VA, Max. Bulb Load: 4400 watt (approx.) ? Battery Capacity : Voltage - 12 Volt, Capacity - 150 Ah, Tall tubularinverter battery ? No. of batteries: 06 ? Key features for Inverter :-Sine wave inverter, Intelligent batterycharging mechanism with adaptive battery charging controltechnology? Key features for Battery : Highly efficient and ideal for heavy dutyapplication with excellent overcharge tolerance, superior performance during long and frequent power cuts and minimum maintenance ? Running Load : 1 desktop PC, 20 LED Bulb 9W, 10 LED Tubelight24W, 8 Fans, 1 Fridge (250 Litre), 1 AC (1.5 Tonne) ? Safety :- MCB for protection from Input main, Auto over-load handling capacity, Bypass switch for supplying output directly from grid in case of UPS fault