Tender For Deposit-Rgndwm-2016-17 Devikulam Block Panchayath-Drinking Water Scheme At 301 Colony - Aanakkuzhy Bhagam In Chinnakanal Grama Panchayath-General Electrical Work
Tender Value
Ref. Documents
Estimated cost
Bid Submission
17 Feb 2023
0 days left
EMD
13404
Bank guarantee accepted
Document Fee
1185
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
devikulam → Kerala
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Deposit-Rgndwm-2016-17 Devikulam Block Panchayath-Drinking Water Scheme At 301 Colony - Aanakkuzhy Bhagam In Chinnakanal Grama Panchayath-General Electrical Work
BOQ
| Sl. No. | Item Description |
| 1 | MOTOR PUMP SET |
| 2 | OD62590/2022-2023:Supply, installation, testing and commissioning of 3 phase ,415 V 5.6 KW/7.50 HPOpen well submersible motorpumpset having total headrange 88-132 MTR , dischargeRange 200-80 LPM , Delivery pipe size 50 mm , AQUATEX TEXMO /Kirloskar/Crompton / equivalent make etc as required. |
| 3 | OD62602/2022-2023:Supply Installation testing and commissioning ofBCH Starter with control panel , with DOL Starter and SPP suitable for 7.5 HP Submersible motor ( BCH SPS DOL -CIT PREM 3PS 13.2 - 20 A CPPYNAL.) etc as required. |
| 4 | 90.14.24.18:Supply & fixingthe following Power Capacitors 3 phase delta connected in positon and giving connection.3 KVAr, 3 phase, 440 V, delta connected, standard duty Metalised Poly Propylene Capacitor, Box Type, suitable for direct connection to motors. |
| 5 | 90.17.12.2:Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required :50 mm dia |
| 6 | 90.17.14.2:Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :50mm dia |
| 7 | OD62678/2022-2023:Supply and fitting of DUTRONUPVC COLUMN pipe 50 mm20 KG CE with required Accessories etc as required. |
| 8 | OD63763/2022-2023:Supply and fitting 50 MM GI socketetc as required. |
| 9 | OD63764/2022-2023:Supply and fitting cable joint tape etc as required. |
| 10 | OD63757/2022-2023:Supply and providing Shellac 50 mletc.as required. |
| 11 | OD63765/2022-2023:Supply and fitting 50 MM X 18" GI Barrel Nipple etc as required. |
| 12 | OD63766/2022-2023:Supply and fitting 50mmSP GI Bend etc as required. |
| 13 | OD63767/2022-2023:Supply and fitting 5/8"GIwasher etc as required. |
| 14 | OD63768/2022-2023:Supply and fitting nut & bolt 2" x 5/8 " etc as required. |
| 15 | OD63769/2022-2023:Supply and fitting 50 mm CI Clamp setheavy duty . etc as required. |
| 16 | OD63770/2022-2023:Supply and fittingUPVC Adaptor set 60 mmDC CI including labour charges |
| 17 | 90.6.6.4:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.6 sq mm |
| 18 | OD63782/2022-2023:Supply and providing Cotton Wasteetc as required. |
| 19 | OD63778/2022-2023:Supply and fixing Insulation tape ( 7592 MX ) etc as required. |
| 20 | OD63777/2022-2023:Supply and fitting 50 MM x 25 MM GI TEE ISI etc as required. |
| 21 | OD63776/2022-2023:Supply and fitting Barrel Nipple GI 25 mm x9 "etc as required. |
| 22 | OD63775/2022-2023:Supply and fitting Ball valve Brass 25 MMwing gold Heavyetc as required. |
| 23 | OD63774/2022-2023:Supply and fitting 25 MM GI socketetc as required. |
| 24 | OD63773/2022-2023:Supply and fitting 25 MM X 15 MMGIBUSH etc as required. |
| 25 | OD63772/2022-2023:Supply and fitting Brass Bush 15 MMX 12 MMetc as required. |
| 26 | OD63771/2022-2023:Supply and fitting Pressure gauge 100 mm 7/14/21/28/35 KG / CM etc as required. |
| 27 | 1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 28 | 1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 29 | 1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C |
| 30 | 90.3.20.3:Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thicknesscomplete with all accessories andlamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture |
| 31 | OD62679/2022-2023:Supply and fixing cast aluminium stove enameled bulk head fitting with deep drawn anodised aluminiumbody, epoxy powder coated, heat resistant prismatic glass coverwith7 W LED to wall / ceilingincluding giving connections with required length of 16/0.20mm PVC insulated and PVC sheathed 3 coreround copper conductor flex wire conforming to relevant ISS or extending the original wiring and makinggood the surface as required. |
| 32 | 1.17.31:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 6 sq. mm |
| 33 | 1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch |
| 34 | 1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet |
| 35 | 90.11.1.14:Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43) |
| 36 | 2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 37 | 2.10.4:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole |
| 38 | 2.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 39 | 2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 40 | 2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 41 | 5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 42 | 90.16.2.1:Supply and laying of the following sizes of B class GIpipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.15.mm dia. G.I pipe ( medium class) |
| 43 | 90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG) |
| 44 | 90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG) |
| 45 | OD73937/2022-2023:Supply and laying bare earthing conductors 10SWGof the following sizes laid 0.6 m below ground level including excavating trench of suitable size and refilling etc. as required (in ordinary soil). |
| 46 | 90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG) |
| 47 | 90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG) |
| 48 | OD62680/2022-2023:Supply and Installation of dust and vermin proof , wall mounting , sintex meter box of size 560x280x170mm ( outside dimension) double doorsuitable for fixing KSEB meter ,fuse units etc, hinged doorconnection for the front side with compartments if necessary , providing vision panel for the meter component , knock out for cable entry and exit. |
| 49 | OD62681/2022-2023:Supply and fixing 63 A Bakelite Fuse with HRC fuse linkand giving connections in the existing meter board/panel. |
| 50 | OD62682/2022-2023:Supply and fixing 63 A 2 way neutral link mounted on DMC/SMC base and giving connections in the existing meter board/panel. |
| 51 | OD62683/2022-2023:Supply and providing iron hook for binding service wire |
| 52 | OD65811/2022-2023:Necessary fee towards KSEB ( CD, OYEC ,AF etc actual will be reimbursed on production of original documents) |
| 53 | OD63784/2022-2023:Supply and providing 25x6mm brass nut and bolt etc. as required. |
| 54 | 90.12.2.39:Supply and laying of one number additional PVC insulated and PVC sheathed armoured aluminium powercable of 1.1KV grade of the following sizes in ground in the same trench in one tier horizontal formation including wideningthe trench by 20 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil)4 core 6 sq mm |
| 55 | 90.12.7.39:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 6 sq mm with factory made clamp |
| 56 | 9.1.32:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm) |
| 57 | 14.7:Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required. |
| 58 | OD73938/2022-2023:Supply and fixing Sintex Junction box GSJB 3020 hingedetc as required Outside dimension ( 333 x 233 x 120) |
AI Tender Summary
Tender Timeline
Feb 02, 2023
11:30 IST
Tender Published
Tender notice published.
CompletedFeb 17, 2023
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedFeb 20, 2023
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender