Public Health Engineering Department-PHED has published Tender For Work Related To Extension Of U.W.S.S. Bhinmal For Ricco Industrial Area, Tehsil: Bhinmal, District Jalore. Submission Date for this Tender is 23-02-2023. Pump House Construction Tenders in bhinmal Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

36026083
Corrigendum : Tender For Work Related To Extension Of U.W.S.S. Bhinmal For Ricco Industrial Area, Tehsil: Bhinmal, District Jalore
Open Tender
Indian
Rajasthan
bhinmal
23-02-2023

Tender Details

Tender For Work Related To Extension Of U.W.S.S. Bhinmal For Ricco Industrial Area, Tehsil: Bhinmal, District Jalore -Pipe Line ( Based On Bsr 2021 Ce ( Tech. ) & Tm Rwssmb Phed Jaipur ) 2 ( 4.1 ) Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Trenches For Water Supply Pipe Lines, Shoring And Strutting If Required As Per Required Gradient And Line Including Safety Provisions Using Site Rails And Stacking Excavated Stuff Including Up To All Required Lead Cleaning The Site Etc. Complete Forlifts Up To 1.5 Depth And Strata As Specified. The Work Also Includesdepositing And Refilling Of Trench With Watering & Ramming / Compacting In Layers And Disposal Of Surplus Excavated Soil As Directed For Lead Up To 50 Mtr. In All Type Of Soil 3 ( 1.1.4 ) Providing, Lowering, Laying In Trenches, Aligning, Fixing In Position And Jointingductileiron ( Di ) Isi Markedk-7Grades&Spipesas Per Is:8329-2000 ( Amendeduptodate ) , Withinternalcementmortar Lining Suitable For Potablewater With Rubber Ring ( Epdm ) Joints As Per Is: 5382-1985 Including All Taxes ( Central And Local ) , Transportation And Freight Charges, Inspection Charges, Loading / Unloading Charges, Including Cost Of Labour And Material, Specials ( Tee, Bend Etc. ) Satisfactory Hydraulic Testing, Disinfection Etc. Complete As Per Technical Specifications And Direction Of Engineer-In-Charge. ( Excluding Earth Work ) Note : Providing And Fixing Of All Requisite Specials As Per Drawing, Design And Layout Are Inclusive In Rm Measurement Of The Item And Shall Not Be Paid Separately. 4 ( I ) 200Mm 5 ( 1.4 ) Providing, Lowering, Laying And Jointing In Trenches, Standard Lengths Hdpeisi Marked Pipes As Per Is-4984: 1995 ( Amended Upto Date ) With Necessary Jointing Material Like Mechanical Connectors, I.E. Thread / Insert Joint / Quick Release Coupler Joint / Compression Fitting Joint Or Flanged Joint And Specials Jointing Pipe Byelectro Fusion Welding Method, Including All Taxes , Transportation And Freight Charges, Inspection Charges, Loading / Unloading Charges, Stacking Of Pipes, Including Cost Of Labour And Material, Specials ( Tee, Bend Etc. ) , Satisfactory Hydraulic Testing, Disinfection Etc. Complete As Per Technical Specifications And Direction Of Engineer-In-Charge Of Following Class And Diameter. ( Excluding Earth Work ) . Note : Providing And Fixing Of All Requisite Specials As Per Drawing, Design And Layout Are Inclusive In Rm Measurement Of The Item And Shall Not Be Paid Separately. Supply May Be In Coil Or Straight Length In 6 M / 12 M. 6 ( I ) 110Mm 7 ( 6.1 ) Providing, Lowering, Aligning, Fixingin Positionin Pipeline, Cid / Fsluicevalvesof Approved Make Of Following Pressure Rating & Dia Complete, Confirming To Is:14846 ( Amended Up To Date ) And Of Following Specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand Wheel Of Grey Cast Iron Of Is:210 / Fg200stem - Ss 304 , Body Seat Ring, Wedge Facing Ring & Bushes - Ltb2 / Ss, Face To Face Dimensions As Per Is 14846 / 2000 ( Amended Up To Date ) , All Exposed Machined Ferrous Surfaces Shall Be Painted With One Coat Of Aluminium Red Oxide Primer Conforming To Is:5660 And Two Coats Of Black Japan Paint Conforming Totype B Of Is 341Or Paint Conforming To Is9862 Or Is2932 ( Non-Toxic- Suitable For Drinking Water ) Applied Inside And Outside, Flanges Drilled As Per Is 1538.Nut-Bolt Confirming To Is:1363 And Is: 1367 / Cs / Galvanised Steel.Insersion Rubber Of Black Epdm 6Mm Thick . Suitablesupport Structure As Per Directions Of Eic. Sluice Valves Including All Jointing & Jointing Material, Labour, Testing And Commissioning Along With Pipe Line As Per Technical Specifications And As Per Direction Of Engineer-In-Charge. Note: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work. Manually Operated Ci Sluice Valve Of Class Pn-1.0 8 ( I ) 100Mm Dia 9 ( Ii ) 200Mm Dia 10 ( 6.3 ) Providing, Lowering, Aligning, Fixing In Position In Pipe Line, Ci Double Flanged Swing Type Non Return Valves ( Nrv ) Of Approved Make Of Following Pressure Rating & Dia Complete, Confirming To Is: 5312 ( Part -1 ) / 2004 ( Amendedup To Date ) And Of Following Specifications: Body, Cover & Disc Of Grey Cast Iron Of Is:210 / Fg200. Face To Face Dimensions As Per Is 5312 ( Part -1 ) :2004 , Flanges Drilled As Per Is:1538. All Exposed Machined Ferrous Surfaces Shall Be Painted With One Coat Of Aluminium Red Oxide Primer Conforming To Is:5660And Two Coats Of Black Japan Paints Conforming Totype B Of Is 341Or Paint Conforming To Is9862 Or Is2932 ( Non-Toxic- Suitable For Drinking Water ) Applied Inside And Outside. Body Seat Ring Of Ss / Cs Door Face Ring - Epdm / Neoprene ( Food Grade Quality ) , Shaft Of Htb1 / Ss- Aisi- 410, Hinge Malleable Cast Iron / Ss Aisi 316 / 410 , Bonnet Gasket Epdm, Bush- Leaded Tin Bronze / Ptet, Gasketepdm / Nbr, Nut-Bolt As Per Is:1363 And Is: 1367 ( Galvanised Steel ) , Insersion Rubber Of Black Epdm 6Mm Thick. Suitablesupport Structure As Per Directions Of Eic Including Jointing & Jointing Material, Labour, Testing And Commissioning Along With Pipeline As Per Technical Specification & As Per Direction Of Engineer-In-Charge. Note: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work. 11 ( I ) 100Mm Dia 12 ( Ii ) 200Mm Dia 13 ( 4.5 ) Dismantling Of Cement Concrete Pavement For Pipe Lineand Chambers By Mechanical Means Using Pneumatic Tools, Cutting The Peripheral Edge By Cc Cutter, Breaking To Pieces Not Exceeding 0.02 Cum In Volume And Stock Piling At Designated Locations And Disposal Of Dismantled Materials Up To A Lead Of 1000 Meters. Measurement For Dismantled Trench To Be Madeas Per Standard Trench Width Specified In Tender Document And No Extra Payment Shallbe Made For Trench Width More Than Specified, Re-Handling Of Material / Earth To Complete The Tasks As Per Technical Specification And Scope Of Work. 14 ( 4.8 ) Providing And Laying In Position Cement Concrete In Specified Grade Over Prepared Base Course Complete Including Finishing, Curing, All Material, Labour, Machinery, Lighting, Guarding For Road Restoration Work In Trenches Of Pipe Line And Chamber Work. Measurement For Cc Work To Be Madeas Per Standard Trench Width Specified In Tender Document And No Extra Payment Shallbe Made For Trench Width More Than Specified, Complete Work As Per Technical Specification And Scope Of Work. M20 Grade Nominal Mix 1: 1.5: 3 ( 1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20Mm Nominal Size ) . 15 Pumping Machinery ( Based On Bsr 2021 Ce ( Tech. ) & Tm Rwssmb Phed Jaipur ) 16 Bsr 2021 / 5.4 Providing, Installation, Testing And Commissioningof Submerged Centrifugal Pump Sets With Motor ( Water Immersed, Dry Air Filled, Class F Insulated Tewc Motor Integrally Mounted On Vollute Casing Pump Sets For Drinking Water ) 3 Phase, + / - 3%, 415 Volt + / - 10%, Along With Suitable Foundation / Installation Device And With 10 Mtr Cable, Material Of Construction Of Impeller Ss, Casing ( Volute ) Ci, Wearing Ring Ss, Etc. Completein All Respect As Perspecification, Scope Of Work And Direction Of Engineer In Charge Of Following Power Rating, Suitable For Prescribed Duty Conditions Of One Of The Makes Approved By Technical Committee. 17 37 Kw ( 45 Hp ) 18 Bsr 2021 / 2.18 Supply & Fixing Of Electric Control Feeder Panel Comprising Of Suitable Rating Mccb, Fully Automatic Star- Delta Starter, Over Load Relay, Amphere Meter With Cts, Volt Meter, Phase Preventor, Suitable Strarting Capacitors, Phase Indicators, Lighting Arrangement Etc Complete Suitable For Three Phase Pump Set. The Panel Should Have Space For Energy Meter ( Supplied By Discom ) . Allthese Equipments Shall Be Housed By Panel Box Made Out From 18 Guage M.S. Sheet With Powder Coating . Panel Should Be Of Minimum Size 900X600x450 Mm With Stand ( Made Of Angle Iron Of Size 35X35x5 Mm ) Duly Bolted / Screwed With Enclosure Box Having 4 Legs. Each Legs Length 18 And Double Door Including In Built Locking System. The Legs Should Be Embeded In M-15 Cement Concrete Plat From.The Size Of Cc Platefrom Should Be Equal Or Bigger Than The Base Size Of Panel Having Height Of At Least 200 Mm From Ground Level. The Panel Should Have Opening Of Suitable Size In Front Of Space For Energy Meter With Glass For Meter Reading.The Operation Of Panel Should Be Suitable For On 440 Volt Ac Supply. 19 Above 15 Hp 20 Providing, Lowering, Aligning, Fixingin Positionin Pipeline, Cid / Fsluicevalvesof Approved Make Of Following Pressure Rating & Dia Complete, Confirming To Is:14846 ( Amended Up To Date ) And Of Following Specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand Wheel Of Grey Cast Iron Of Is:210 / Fg200stem - Ss 304 , Body Seat Ring, Wedge Facing Ring & Bushes - Ltb2 / Ss, Face To Face Dimensions As Per Is 14846 / 2000 ( Amended Up To Date ) , All Exposed Machined Ferrous Surfaces Shall Be Painted With One Coat Of Aluminium Red Oxide Primer Conforming To Is:5660 And Two Coats Of Black Japan Paint Conforming Totype B Of Is 341Or Paint Conforming To Is9862 Or Is2932 ( Non-Toxic- Suitable For Drinking Water ) Applied Inside And Outside, Flanges Drilled As Per Is 1538.Nut-Bolt Confirming To Is:1363 And Is: 1367 / Cs / Galvanised Steel.Insersion Rubber Of Black Epdm 6Mm Thick . Suitablesupport Structure As Per Directions Of Eic. Sluice Valves Including All Jointing & Jointing Material, Labour, Testing And Commissioning Along With Pipe Line As Per Technical Specifications And As Per Direction Of Engineer-In-Charge. Note: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work. Manually Operated Ci Sluice Valve Of Class Pn-1.0 21 ( I ) 125Mm Dia 22 Providing, Lowering, Aligning, Fixing In Position In Pipe Line, Ci Double Flanged Swing Type Non Return Valves ( Nrv ) Of Approved Make Of Following Pressure Rating & Dia Complete, Confirming To Is: 5312 ( Part -1 ) / 2004 ( Amendedup To Date ) And Of Following Specifications: Body, Cover & Disc Of Grey Cast Iron Of Is:210 / Fg200. Face To Face Dimensions As Per Is 5312 ( Part -1 ) :2004 , Flanges Drilled As Per Is:1538. All Exposed Machined Ferrous Surfaces Shall Be Painted With One Coat Of Aluminium Red Oxide Primer Conforming To Is:5660And Two Coats Of Black Japan Paints Conforming Totype B Of Is 341Or Paint Conforming To Is9862 Or Is2932 ( Non-Toxic- Suitable For Drinking Water ) Applied Inside And Outside. Body Seat Ring Of Ss / Cs Door Face Ring - Epdm / Neoprene ( Food Grade Quality ) , Shaft Of Htb1 / Ss- Aisi- 410, Hinge Malleable Cast Iron / Ss Aisi 316 / 410 , Bonnet Gasket Epdm, Bush- Leaded Tin Bronze / Ptet, Gasketepdm / Nbr, Nut-Bolt As Per Is:1363 And Is: 1367 ( Galvanised Steel ) , Insersion Rubber Of Black Epdm 6Mm Thick. Suitablesupport Structure As Per Directions Of Eic Including Jointing & Jointing Material, Labour, Testing And Commissioning Along With Pipeline As Per Technical Specification & As Per Direction Of Engineer-In-Charge. Note: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work. 23 ( I ) 125Mm Dia 24 Pump House ( Based On Bsr 2021 Ce ( Tech. ) & Tm Rwssmb Phed Jaipur ) 25 ( 8.1 ) Construction Of Pump House Of Required Size Suitable For Installation Of Maximum 4 No. Monoblock Pump Sets As Per Approved Ga Drawing, Scope Of Work And Technical Specification Complete Work In All Respect. 26 ( 9.4 ( Pwd ) ) Structural Steel Work Welded In Built Up Sections, Trusses And Framed Work Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete Above Plinth Level Up To 4.5 Mtr. Height In R.S. Joists Flats, Tees, Angles And Channels. 27 ( 11.1.6 ) Electromegnetic Flow Meter- Sitc Of D / F Full Bore Type Electromagnetic Flow Meter Of Approved Make Of Following Dia And Specifications Complete: Media : Water ( Raw / Chlorinated ) , Pressure : Up To 1.5Mpa, Process Temp: - 50 Deg C, Flow / Meter Tube : Ss 304, Electrode : Ss Aisi 316L / Hastelloy C276 / Tantalum, Lining Material : Hard Rubber / Neoprene / Poly-Urethane ( Pu ) , Flange : Ss / Cs, Flange Standard & Rating : Ansi 150, Coil Housing : Ss Aisi 304 / Carbon Steel / Die Cast Aluminium, With Anticorrosive Paint & Provide Completely Sealed ( Leak Proof ) Construction As Per Requirement Of Iec 60529, Accuracy : ± 0.5 % M.V.- Velocity 0.3 To 10 M / S, Transmitter / Signal Convertor Enclosure : Die Cast Aluminium, Power Supply : 80-240 V Ac - 50Hz, Output 1 : 4-20 Ma, Output 2: Pulse, Communication Output : Rs 485 / Heart, Display Type : Lcd / Led Display, Cable Entry : M20 X 1.5, Provision Of Ram / Prom To Store Calibration And Configuration Parametersand Totalizer Value During Power Failure, Protection Category- Ip 68 For Sensor ( Flow Tube ) And Ip 67 For Transmitter / Convertor, Including Surge Arrester, If Required, And All Materials Required For Making Connection With Existing Pipeline Including Cutting The Existing Pipeline Etc. Complete In All Respect As Per Technical Specification And As Per Direction Of Engineer In-Charge. Note: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work. Efm 200 Mm 28 Supply Of Chain Puly ( Capacity 3 Tons ) 29 Railway Crossing Work 30 ( Phed Bsr 2022, Item No. 4.11 ) Supply Laying And Pushing Of Ms Casing Pipe Of Specified Thickness Approved By Concerned Department Authority By Trenchless Method Adopting Any Suitable Technology Below Ground At Required Depth Under Running Traffic Condition As Per Highway / Railway Standard Including Carrying Out Survey Work At The Job Site For Determining Underground Cable Trenches Like Telephone, Cable, Water & Sanitary Lines And Resistivity Test For Finding The Soil Strata Using Necessary Equipments For Completion Of Works, Mobilizing Of Machineries And Specialized Crew At The Job Site Complete In All Respect, Including Excavation Of Driven Pit And Exit Pit ( Up To 3 Meter Depth ) With Proper Protection At These Sites With Shoring Sheets And Ismb. Providing Ms Cutting Edges For Front Shield And Constructing Thrust Bed At Designated Level. Necessary Dewatering And Providing Concrete Foundation At The Base Of The Driven Pit, Pvc / Rubber Saddle As Per The Requirement Of Highway / Railway Authority, Crane For Handing Of Pipe And Any Other Machinery, Tools, And Tackles Required, Construction Of Temporary Works As Per Design, Drawing And Method As Per Approved Byauthority Specification And The Direction Of The Engineer. Apply Corrosion, Resistant, Protection On Inside And Outside Of Casing Pipeas Per Technical Specification. 31 ( 4.11.2 ) 400 Mm Dia 8 Mm Thick Casing Pipe . 32 ( Phed Bsr 2022 Item No. 1.1.4 ) Providing, Lowering, Laying In Trenches, Aligning, Fixing In Position And Jointingductileiron ( Di ) Isi Markedk-7Grades&Spipesas Per Is:8329-2000 ( Amendedup Todate ) , Withinternalcementmortar Lining Suitable For Potablewater With Rubber Ring ( Epdm ) Joints As Per Is: 5382-1985 Including All Taxes ( Central And Local ) , Transportation And Freight Charges, Inspection Charges, Loading / Unloading Charges, Including Cost Of Labour And Material, Specials ( Tee, Bend Etc. ) Satisfactory Hydraulic Testing, Disinfection, Commissioning Etc. Complete As Per Technical Specifications And Direction Of Engineer-In-Charge. ( Excluding Earth Work ) Note : Providing And Fixing Of All Requisite Specials As Per Drawing, Design And Layout Are Inclusive In Rm Measurement Of The Item And Shall Not Be Paid Separately. 200Mm Dia Di Carrier Pipe 33 ( Phed Bsr2022 Item No.6.8.1.5 ) Providing, Lowering, Aligning, Fixing In Position In Pipe Line At Work Site, Di D / F Resilient Seated ( Soft Seated ) Sluice Valves ( Gate Valves ) , Vacuum Tight ( Bubble Tight ) , Straight And Pocket Less Body Passage Of Approved Make Of Following Class & Dia Complete Confirming To Bs-En-1171 / Awwa C-509 And Of Following Specifications: Body & Bonnet Of Ductile Cast Iron Of Grade Ggg40 / Ggg50 As Per Din 1693 Or Gr Sg-400 / 12 As Per Is 1865 Or Equivalent Grade As Per Is :3896-Part2-1985 And Subsequent Revisions, Wedge Of Same Material As Body & Shall Vulcanisedrubber Lined With Epdm ( Food Grade Quality ) And Seals Of Nbr Face To Face Dimensions As Per Bs 5163-89 / Is 14846 / 2000 ( Amended Up To Date ) / Din 3202 F4, Stem / Spindle Of Ss Aisi 316 / 410 Electrostatic Epoxy Powder ( Ep-P ) / Fusion Bond Epoxy ( Non-Toxic- Suitable For Drinking Water ) Coated With Minimum Thickness Of 250 Microns Inside And Outside, Drilled As Per Is 1538. Nut-Bolt Confirming To Is:1363 And Is: 1367 ( Galvanised Steel ) Insertion Rubber Of Black Epdm 6Mm Thick. Suitablesupport Structure As Per Directions Of Eic, Sluice Valves Including All Jointing & Jointing Material, Labour, Testing And Commissioning Along With Pipe Line As Per Technical Specifications And As Per Direction Of Engineer-In-Charge. Note: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work. Manually Operated Resilient Seated Sluice Valves Of Class Pn 1.6 200Mm Dia 34 ( Phed Bsr 2022 Item No. 9.1 ) Construction Of Rcc Sluice Valve Chamber For Different Type Of Valves Including Earthwork Excavation, 100Mm Pcc M15as Leveling Course, Rcc M25 Grade For Base Slab, Side Wall & Cover Slab , Including Cost Of Steel Reinforcement , Form Work, Pre-Cast, Plastic Encapsulated Ci / Ms Foot Rest, Ms Flats For The Support Of Pre-Cast, Proper Curing Of Concrete Work Complete In All Respect As Perspecifications And Standard Drawings And As Directed By Engineer-In-Charge. 35 ( 9.1.1. ) For Class-Aa Loading 36 ( 9.1.1.5 ) Sluice Valve Chamber Of Size 1.61M X1.75M X2.85M For Pipe Size-From 500-To-700Mm

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 09-Feb-2023 1st Amendment Date 16-02-2023
2 16-Feb-2023 Date Extension Date 23-02-2023

Key Value

Document Fees
INR 1000 /-
EMD
INR 123400.0 /-
Tender Value
INR 61.70 Lakhs /-

BOQ Items

Name of Work: WORK RELATED TO EXTENSION OF U.W.S.S. BHINMAL FOR RICCO INDUSTRIAL AREA, TEHSIL: BHINMAL, DISTRICT JALORE
Sl. No. Item Description
1Pipe line (Based on BSR 2021 CE (Tech.) & TM RWSSMB PHED Jaipur)
2(4.1) Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches for water supply pipe lines,shoring and strutting if required as per required gradient and line including safety provisions using site rails and stacking excavated stuff including up to all required lead cleaning the site etc. complete forlifts up to 1.5 depth and strata as specified. The work also includesdepositing and refilling of trench with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed for lead up to 50 mtr. In all type of soil
3(1.1.4) Providing, lowering, laying in trenches, aligning, fixing in position and jointingDuctileIron(DI)ISI markedK-7gradeS&Spipesas per IS:8329-2000 (amendeduptodate),withinternalcementmortar lining suitable for potablewater with rubber ring (EPDM)joints as per IS: 5382-1985 including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges,including cost of labour and material, specials (Tee, bend etc.) satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge. (excluding earth work) Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.
4(i) 200mm
5(1.4) Providing, lowering, laying and jointing in trenches,  standard lengths HDPEISI marked Pipes as per IS-4984: 1995 (amended upto date)with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe byelectro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work) . Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. Supply may be in coil or straight length in 6 M/12 M.
6(i) 110mm
7(6.1) Providing,lowering, aligning,fixingin positionin pipeline,CID/FSluicevalvesof approved make of following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200Stem - SS 304 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS, Face to face dimensions as per IS 14846/2000 (amended up to date), All exposed machined ferrous surfaces shall be painted with one coat of aluminium red oxide primer conforming to IS:5660 and two coats of black Japan paint conforming toType B of IS 341or paint conforming to IS9862 or IS2932( Non-Toxic- suitable for drinking water) applied inside and outside, Flanges Drilled as per IS 1538.Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steel.Insersion rubber of black EPDM 6mm thick . Suitablesupport structure as per directions of EIC. Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. Manually Operated CI Sluice valve of Class PN-1.0
8(i) 100mm dia
9(ii) 200mm dia
10(6.3) Providing, lowering, aligning, fixing in position in pipe line, CI double flanged swing type Non Return Valves (NRV)of approved make of following Pressure rating & dia complete, confirming to IS: 5312 (part -1)/ 2004 (amendedup to date) and of following specifications: Body, Cover & disc of Grey cast iron of IS:210/ FG200. Face to face dimensions as per IS 5312 (part -1):2004 , Flanges Drilled as per IS:1538. All exposed machined ferrous surfaces shall be painted with one coat of aluminium red oxide primer conforming to IS:5660and two coats of black Japan paints conforming toType B of IS 341or paint conforming to IS9862 or IS2932( Non-Toxic- suitable for drinking water) applied inside and outside. Body seat ring of SS/CS Door face ring - EPDM/ Neoprene (food grade quality) ,Shaft of HTB1/ SS- AISI- 410, Hinge Malleable cast iron / SS AISI 316/410 ,Bonnet Gasket EPDM, Bush- Leaded tin Bronze/ PTET, GasketEPDM/NBR,Nut-Bolt as per IS:1363 and IS: 1367 (galvanised steel) ,Insersion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.
11(i) 100mm dia
12(ii) 200mm dia
13(4.5) Dismantling of cement concrete pavement for pipe lineand chambers by mechanical means using pneumatic tools, cutting the peripheral edge by CC cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be madeas per standard trench width specified in tender document and no extra payment shallbe made for trench width more than specified, re-handling of material/earth to complete the tasks as per technical specification and scope of work.
14(4.8) Providing and laying in position cement concrete in specified grade over prepared base course complete including finishing, curing, all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be madeas per standard trench width specified in tender document and no extra payment shallbe made for trench width more than specified,complete work as per technical specification and scope of work. M20 grade Nominal Mix 1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size).
15Pumping Machinery (Based on BSR 2021 CE (Tech.) & TM RWSSMB PHED Jaipur)
16BSR 2021/5.4 Providing, installation, testing and commissioningof Submerged Centrifugal Pump sets with motor ( water immersed, dry air filled, class "F" insulated TEWC motor integrally mounted on vollute casing pump sets for drinking water ) 3 phase, +/- 3%, 415 volt +/- 10%, along with suitable foundation/ installation device and with 10 mtr cable, material of construction of impeller SS, casing (volute) CI, wearing ring SS, etc. completein all respect as perspecification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions of one of the makes approved by Technical Committee.
1737 KW (45 HP)
18BSR 2021/2.18 Supply & fixing of electric control feeder panel comprising of suitable rating MCCB, fully automatic star- delta starter, over load relay, amphere meter with CTs, volt meter, phase preventor, suitable strarting capacitors,phase indicators, lighting arrangement etc complete suitable for three phase pump set. The panel should have space for energy meter (supplied by DISCOM). Allthese equipments shall be housed by panel box made out from 18 guage M.S. Sheet with powder coating . Panel should be of minimum size 900x600x450 mm with stand (made of angle iron of size 35x35x5 mm) duly bolted / screwed with enclosure box having 4 legs. each leg"s length 18" and double door including in built locking system. The leg"s should be embeded in M-15 cement concrete plat from.The size of CC platefrom should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading.The operation of panel should be suitable for on 440 Volt AC Supply.
19Above 15 HP
20Providing,lowering, aligning,fixingin positionin pipeline,CID/FSluicevalvesof approved make of following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200Stem - SS 304 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS, Face to face dimensions as per IS 14846/2000 (amended up to date), All exposed machined ferrous surfaces shall be painted with one coat of aluminium red oxide primer conforming to IS:5660 and two coats of black Japan paint conforming toType B of IS 341or paint conforming to IS9862 or IS2932( Non-Toxic- suitable for drinking water) applied inside and outside, Flanges Drilled as per IS 1538.Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steel.Insersion rubber of black EPDM 6mm thick . Suitablesupport structure as per directions of EIC. Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. Manually Operated CI Sluice valve of Class PN-1.0
21(i) 125mm dia
22Providing, lowering, aligning, fixing in position in pipe line, CI double flanged swing type Non Return Valves (NRV)of approved make of following Pressure rating & dia complete, confirming to IS: 5312 (part -1)/ 2004 (amendedup to date) and of following specifications: Body, Cover & disc of Grey cast iron of IS:210/ FG200. Face to face dimensions as per IS 5312 (part -1):2004 , Flanges Drilled as per IS:1538. All exposed machined ferrous surfaces shall be painted with one coat of aluminium red oxide primer conforming to IS:5660and two coats of black Japan paints conforming toType B of IS 341or paint conforming to IS9862 or IS2932( Non-Toxic- suitable for drinking water) applied inside and outside. Body seat ring of SS/CS Door face ring - EPDM/ Neoprene (food grade quality) ,Shaft of HTB1/ SS- AISI- 410, Hinge Malleable cast iron / SS AISI 316/410 ,Bonnet Gasket EPDM, Bush- Leaded tin Bronze/ PTET, GasketEPDM/NBR,Nut-Bolt as per IS:1363 and IS: 1367 (galvanised steel) ,Insersion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.
23(i) 125mm dia
24Pump House (Based on BSR 2021 CE (Tech.) & TM RWSSMB PHED Jaipur)
25(8.1) Construction of Pump house of required size suitable for installation of maximum 4 no. monoblock pump sets as per approved GA drawing, scope of work and technical specification complete work in all respect.
26(9.4 (PWD)) Structural steel work welded in built up sections, trusses and framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete above plinth level up to 4.5 Mtr. height in R.S. Joists flats, tees, angles and channels.
27(11.1.6) Electromegnetic Flow meter- SITC of D/F Full bore type Electromagnetic Flow Meter of approved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated) ,Pressure : up to 1.5MPa, Process temp: - 50 deg C, Flow/Meter Tube : SS 304,Electrode : SS AISI 316L /Hastelloy C276/ Tantalum, Lining Material : Hard Rubber/ Neoprene / Poly-urethane (PU) , Flange : SS / CS, Flange Standard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Cast Aluminium, with anticorrosive paint & provide completely sealed (leak proof) construction as per requirement of IEC 60529, Accuracy : ± 0.5 % M.V.- velocity 0.3 to 10 m/s, Transmitter/ signal convertor Enclosure : Die Cast Aluminium, Power Supply : 80-240 V AC - 50Hz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart,Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68 for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, if required, and all materials required for making connection with existing pipeline including cutting the existing pipeline etc. complete in all respect as per technical specification and as per direction of Engineer In-Charge. Note: Rates are exclusive of tail piece / dismantling joints and earth work. EFM 200 mm
28Supply of Chain puly (Capacity 3 tons)
29Railway Crossing Work
30(PHED BSR 2022,Item No. 4.11)Supply laying and pushing of MS casing pipe of specified thickness approved by concerned department authority by trenchless method adopting any suitable technology below ground at required depth under running traffic condition as per Highway/ Railway standard including carrying out survey work at the job site for determining underground cable trenches like telephone, cable, water & sanitary lines and resistivity test for finding the soil strata using necessary equipments for completion of works, mobilizing of machineries and specialized crew at the job site complete in all respect, including excavation of driven pit and exit pit (up to 3 meter depth) with proper protection at these sites with shoring sheets and ISMB. Providing MS cutting edges for front shield and constructing thrust bed at designated level. Necessary dewatering and providing concrete foundation at the base of the driven pit, PVC/Rubber saddle as per the requirement of Highway/Railway authority, crane for handing of pipe and any other machinery, tools, and tackles required, construction of temporary works as per design, drawing and method as per approved byauthority specification and the direction of the Engineer. Apply corrosion, resistant, protection on inside and outside of casing pipeas per technical specification.
31(4.11.2) 400 mm Dia 8 mm thick casing pipe .
32(PHED BSR 2022 Item No. 1.1.4) Providing, lowering, laying in trenches, aligning, fixing in position and jointingDuctileIron(DI)ISI markedK-7gradeS&Spipesas per IS:8329-2000 (amendedup todate),withinternalcementmortar lining suitable for potablewater with rubber ring (EPDM)joints as per IS: 5382-1985 including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges,including cost of labour and material, specials (Tee, bend etc.) satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge. (excluding earth work) Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. 200mm dia DI Carrier Pipe
33(PHED BSR2022 Item No.6.8.1.5) Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confirming to BS-EN-1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as body & shall vulcanisedrubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS AISI 316/410 Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367(Galvanised steel) Insertion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. Manually Operated Resilient Seated Sluice Valves of Class PN 1.6 200mm dia
34(PHED BSR 2022 Item No. 9.1) Construction of RCC Sluice valve chamber for different type of valves including earthwork excavation, 100mm PCC M15as leveling course, RCC M25 grade for base slab, side wall & cover slab , including cost of steel reinforcement , form work, Pre-cast, Plastic encapsulated CI/MS Foot Rest, MS flats for the support of pre-cast, proper curing of concrete work complete in all respect as perspecifications and standard drawings and as directed by Engineer-in-Charge.
35(9.1.1.) For Class-AA loading
36(9.1.1.5) Sluice valve chamber of size 1.61m x1.75m x2.85m for pipe size-from 500-to-700mm