Housing Urban and Rular Development Government Departments Closing in 0 days TDR #36021819

Tender For Construction And Renovation Of 4 Nos Class Room, 1 Nos Laboratory, Bounadary Wall, Toilets And Water Supply Work, At Rajkiya Inter College Ghorawal District-Sonbhadra.

Issued by Government Departments · ghorawal, Uttar Pradesh
Tender Value
3.31 Crore
Estimated cost
Bid Submission
07 Feb 2023
0 days left
EMD
6.64 Lakhs
Bank guarantee accepted
Document Fee
17700
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
ghorawal → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Construction And Renovation Of 4 Nos Class Room, 1 Nos Laboratory, Bounadary Wall, Toilets And Water Supply Work, At Rajkiya Inter College Ghorawal District-Sonbhadra.

BOQ

Name of Work:-CONSTRUCTION & RENOVATION OF 4 NOS CLASS ROOM, 1 NOS LABORATORY, BOUNADRY WALL, TOILETS AND WATER SUPPLY WORK, AT- RAJKIYA INTER COLLEGEGHORAWAL DISTRICT SONBHADHRA (U.P.)(52/UPPCL/GM-1/E-TENDER/2022-23 Dated-17.01.2023)
Sl. No. Item Description
1CONSTRUCTION & RENOVATION OF 4 NOS CLASS ROOM, 1 NOS LABORATORY, BOUNADRY WALL, TOILETS AND WATER SUPPLY WORK, AT- RAJKIYA INTER COLLEGEGHORAWAL DISTRICT SONBHADHRA (U.P.)
2Main Building (Civil work)
3Excavation of foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches.
4Filling of carted Earth.
5Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 kms. from the site of work and including watering, dressing etc rate to include cost of all materials labour T & P etc required for proper completion of work.
6Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded stone aggregate 40 mm nominal size) and curing complete, including cost of form- work,in foundation and floors.
7Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete
8R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit in the proportion of 1:1.5:3 (1 cement : 1.5 coarse sand : 3 stone aggregates) in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-20.
9As in item no. 6 above but for slabs (Using 1:1.5:3(1 cement : 1.5 coarse sand : 3 stone aggregates) Mix concrete) (M-20)
10As in item 6 but for thelighterbeams i.e. having spans upto 6 m. (Using 1:1.5:3(1 cement : 1.5 coarse sand : 3 stone aggregates) Mix concrete) (M-20)
11Boring with hydraulic piling rigs with power units, providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap) : Extra over single under ream for providing additional bulbs in under reamed piles, under specified diameter(only the nos. of extra bulbs are to be paid)
12Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge.Single pile upto 50 tonne Safe capacity
13Intial test
14Routine Test
15As in item 6 abovebut inR.C.C.Raft foundation and footingwithapproved stone ballast.(Using1:1.5:3Mix concrete).(1 cement : 1.5 coarse sand : 3 stone aggregates).(M-20)
16As in item 3 above but in R.C.C. columns in1:1.5:3(1 cement : 1.5 coarse sand : 3 stone aggregates) having strength not less than (M-20). (PWD- 289)
17M-150 brick work in 1:6 (one cement and six coarse sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work.
18Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size)
19Applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
20Same as in item no. 11 abovebutin super-structure above plinth level up to floor two level ( up to two storeys ) includingnecessarycutting and moulding of brick work asrequiredand also including honeycombed brick work in thickness of wall more than 12cms. (1:6 cement : coarse sand)
21Same as in item no. 14 but in1:4 cement and coarse sand mortar in superstructure for wall thickness 12 cms & below brick work.
22P/F Mild Fe 500 steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level.
2315 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 coarse sand F.M. 2.25
2412mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or roundedangles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement : 6 coarse sand F.M. 2.25
25Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.
26Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.
2725mm thick 1:2:4 plain cement concrete floor (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement.
28Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.
29Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.
30P/L 20mm white Kota stone flooring over 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid over jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete.
31Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
32Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.
3335 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
34Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured).
35Mild steel or iron work of small sizes and sections such as holding down bolts, hold fast tierods,gratings etc. (when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing.
36Providing & fixing of hold fast for chaukhatsof doors and windows.
37Providing & fixing of door / windows grill.
38Z-Section steel windows (openable)
39Angle iron door chaukhat 40*40*5
40Fixing of Door, windows/ventilators chaukhats in position.
41Door chaukhats
42Window chaukhats
43Ventilator chaukhats
44Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger, J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost ofall materials.
45Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm).
46Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost of all materials. (For Ceiling)
47Providing and applying white cement based putty of average thickness 1 mm, of approved brand &anufacturer, over the plastered wall surface to prepare the surface even & smooth complete.
48Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete.
49Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm .
50Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete.
51(a) 150 mm x 10mm
52(a) 200 mm x 10mm
53Providing and fixing stainless steel handles with screws etc. complete (a) 125 mm.
54Providing & laying \"brick Coba\" 120mm thick laid with M-150 class brick bat coba 7.50 cm thick with gap of 15mm to each other, over 20mm thick base of cement mortar 1:4 cement and coarse sand mixed with water proofing compound spreading cement slurry mixed with acrylic cement concrete water proofing compound filled gaps of coba & top of coba mortar mixed with water proofing compound in 1:4 cement and coarse sand mortar finished smooth & top mashed false square 30 cm x 30 cm and side wall parapet shall be mono lythic plaster wall upto 30cm higher and junction and corner shall be rounded by brick ballast cement and coarse sand masonry coba with top finished plaster mixed with acetic water proofing compound @ 2% by weight & including S/o all material, labour T & P etc complete for proper completion of work.
55Painting two coat over priming coat (but including cost of priming coat) on steel and other metal surfaces up to 10 cm. width or girth or small articles not exceeding 0.10sqm in area white superior synthetic enamel such as LUXOL3,Hi-gloss apcolite superlac, DULUX specified brushing to give an even shade and including cleaning the surface of all dirt,dust and other foreign matter sand papering and stoping including cost of all materials, labour tools and plants etc. required for proper completion of the work.
56Same as item above but on new wood surface.
57Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes.
58Construction of drain alongwith apron. (150x150) mm
59S/O Hand rail and balustrade modular system passive SS-304 grade decorative railing system comprising of hand rail 50mm and 1mm thick and 3 No Horizontal steel pipe of 19mm dia and 1.5mm thick of equal spacing with balustrade to SS pipe of 38mm and 1.5mm thick @ 1200mm C/C of passivated SS 304 grade and fix duly on the floor with specially rivet expansion bolt and finish the surface foor and covering with steel show with all visible stainless metal of 304 grade in satin finish hight of railing is 900mm as per detailed specification.
60Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer.
61PLUMBING WORK
62Providing & fixing white vitereous china water closet squatting pan ISI marked (Indian type W.C. pan) with 100mm sand cast iron P or S trap, 10/12.5 litrsPVC low level flushing cistern with fittings & brackets 40mm dia C.P. flush pipe with fitting & clamps, 20mm over flow pipe with specials and mosquito proof coupling of approved municipal design, painting wherever required including cutting & making good the walls & floors where required. Orissa Pattern W.C. pan of size580x 440mwith integral type foot rests flush pipe and over flow arrangement.
63Same as above but for European type W.C. pan with black plastic seat and lid. Make- Cera, Hindustan.
64Providing & fixing white vitreous china wash basin with C.I. brackets painted white, 15mmbrass pillar taps, brass chain with rubber plug, 32mmbrass waste of standard pattern including cutting & making good the walls wherever required.
65Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete.
66Providing & fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick asbestos cement sheet ground fixed to wooden cleats with C.P. brass screws and washers.
67Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.
68Providing and Fixing C.P brass Abulation health faucet assembly with 1.0 m long braided PVC hose with mounting brackets fixed on wall complete. [FOR EWC]
69Providing and Fixing C.P. brass Two-way angle valve for EWC points & for fixing Abulation Health Faucet of approved quality conforming to IS:8931 15mm nominal bore
70Supplying & Fixing of CP soap tray fixed to the wall with PVC rubber plug with CP brass screws- Make -ESSCO AEC=1131
71Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,
72Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.
73Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
74Providing, Fixing, jointing and testing in position of ISI marked UV stabilized UPVC pipes for soil, waste, and vent, Type-B as per IS:13592 suitable for rubber ring joints for horizontal pipes including all necessary specials and fittings (confirming to IS:14735) i.e, bends tees junctions (with or without doors). reducers WC connectors, couplers, cowels, clamps & hangers rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamps & hangers etc. inside duct / suspended from floor under false ceiling for proper completion of the work. The rubber ring shall confirm to IS:5382 (Make :Supreme /Finolex / Prince) (Pipe support: Intellotech / Easyflex / Chilly.
75110 mm dia
7675 mm dia
77Providing & Fixing UPVC Floor trap of self cleaning design with CP Jali complete in all respects. (Make : Supreme / Finolex)
78Providing and fixing on wall face unplasticised PVC moulded fittings / accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion.
79Reducing Tee 100X100X75mm
80Door Tee
81110X110X75mm
8275X75X75mm
83Bend
84110 mm
8575 mm
86Terminal guard
87110 mm
8875 mm
89Providing and fixing G.I. pipes complete with G.I. fittings and clamps,i/c cutting and making good the walls etc.
90Expansion on Wall
9132 mm dia nominal bore. (medium duty)
92Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work.
9332 mm diameter pipe.
94Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
9525 mm nominal outer dia Pipes
9640 mm nominal outer dia Pipes
97Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.
9815 mm nominal outer dia Pipes
9920 mm nominal outer dia Pipes
100Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931
101Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.
102Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931
103Providing and fixing gun metal gate valve with C.I. wheel of approvedquality (screwed end)
104Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :
105Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
106Supply and fixing of UPVC SWR pipe type -B confirming to IS-13592 including jointing the pipes with rubber ring lubricant and UpVC SWR cuplar confirming to IS-14735 also including excavation of trences as before but excluding supply and cost of other fitting such as elbow bead, tee and Y-tee including supply of all material labour and t&p required for proper completion of the work.
107a) 110mm diameter
108b) 160mm diameter
109Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design :
110a) 110mm diameterS.W.R. Pipe
111b) 160mm diameterS.W.R. Pipe
112Providing & fixing G.I. pipes complete with G.I. fittings includingtenching and refilling etc. (external work)
11350mm nominal bore.
11440mm nominal bore.
115Constructing brick masonry chamber 600 x 600x750mm insidewithF.P.S. brickwork in cement mortar 1:4 (1 cement : 4 coarse sand) for Sluice Valve / Air Valve, with C. I. surface box 100 mmtop diameter, 160 mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slabwith 1 : 2 : 4 mix (1 cement : 2 coarsesand : 4 gradestone aggregate 20 mm nominal size); necessary excavation,foundationconcrete 1:5:10 (1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size) and inside plasteringwithcement mortar 1 : 3 (1 cement : 3 coarsesand ) 12mmthick finished with a floatingcoatofneat cementcomplete as per standarddesign
116EXTERNAL SEWERAGE WORK
117Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m.including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m.
118Providing, Fixing, jointing and testing in position of ISI marked UV stabilized UPVC pipes for soil, waste, and vent, Type-B as per IS:13592 suitable for rubber ring joints for horizontal pipes including all necessary specials and fittings (confirming to IS:14735) i.e, bends tees junctions (with or without doors). reducers WC connectors, couplers, cowels, clamps & hangers rubber rings, clean outs etc. fixing at wall/ ceiling/ floor level supported by clamps & hangers etc. inside duct / suspended from floor under false ceiling for proper completion of the work. The rubber ring shall confirm to IS:5382 (Make :Supreme /Finolex / Prince) (Pipe support: Intellotech / Easyflex / Chilly.
119110 mm dia
12075 mm dia
121Providing & laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40mm nominal size) alround S.W. Pipes including bed concrete as per standard design.
122Constructing brick masonry manholewith F.P.S.bricksin cement mortar 1 : 4 (1 cement : 4 coarse sand) RCC top slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4gradestone aggregate 20mm nominal size); foundation concrete 1:4:8 mix(1 cement : 4 coarse sand : 8 gradedstoneaggregate40 mm nominalsize) insideplastering 12 mm thickwith cementmortar 1:3 (1cement 3 coarse sand ) finished with a floating coat of neat cement and makingchannels incementconcrete 1:2:4 (1cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) finishd with a floating coat ofneatcement completeasper standard design
123Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg)
124Extra for depth for manholes
125Size 90x80 cm
126Size 120x90 cm
127Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design
128Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:
129Construction of Septic tank & Soak pit
130Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design:
131Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality.
132Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-incharge, upto 90 metre depth below ground level. Drilling of 300mm dia bore hole manually.
133Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.
134Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
135Supplying, filling, spreading & leveling gravels of size range 5 mm to 10mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
136Supplying, filling, spreading & leveling coarase sand of size range 1.5 mm to 2mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer-in-charge.
137Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/medium/coarse, in required grading & size as per actual requirement, all complete as per direction of Engineer-in-charge.
138Excavating trenches in all kinds ofsoil of required width for pipes. including excavation for sockets and dressing of sides, ramming of bottoms, including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m.
139Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :
140Providing & laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40mm nominal size) alround S.W. Pipes including bed concrete as per standard design.
141Construction of Brick massonary INSPECTION chamber 60x60x60 cm with bricks class designation 50 in cement mortar 1:4 (1 cement : 4 coarse sand) including CI Cover with frame light weight complete as per design .with FPS bricks
142Constructing masonry Drain 300mm wide & 450 mm average depth
143Electrification Work
144Wiring point for light with 1.5 sq.mm FR PVC insulated multistrand copper conductor cable as earth wire drawn inside the medium class PVC conduit, with modular type switch and ceiling rose/angle/batten holder on 3 mm, thick phenolic laminated backelite sheet etc. complete in all respects, as directed including matching colour wash. (As per PWD SOR 2018 SI No. - 2018SI No. 138C )
145Wiring point for two ways light with 1.5 sq.mm FR PVC insulated multistrand copper conductor cable as earth wire drawn inside the medium class PVC conduit, two ways 2 nos. modular type switch and ceiling rose/angle/batten holder on 3 mm, thick phenolic laminated backelite sheet etc. complete in all respects, as directed including matching colour wash. (As per PWD SOR 2018SI No. - 139C)
146Wiring point for plug with 1.5 sq.mm FR PVC insulated multistrand copper conductor cable as earth wire drawn inside the medium class PVC conduit, modular switch and socket etc. complete in all respects, as directed including matching colour wash. (As per PWD SOR 2018 SI No. - 141C )
147Supply & fixing of call bell with 1.5 sq.mm FR PVC insulated multistrand copper conductor cable as earth wire drawn inside the medium callapvc conduit with modular type bell push etc. complete in all respect. (As per PWD SOR 2018SI No. - 142C)
148Wiring point for fan/ fress air fan with 1.5 sq.mm FR PVC insulated multistrand copper conductor cable as earth wire drawn inside the conduit, modular switch and ceiling rose on 3 mm, thick phenolic laminated backelite sheet etc. complete in all respects, as directed including matching colour wash. (As per PWD SOR 2018SI No. - 140 C)
149Wiring point for H.P.M.V./Sodium Vapour Lamp with 1.5 sq.mm FRLSHPVC insulated multistrand Single Core copper conductor cable in heavy guage PVc Conduit partlt concealed in wall and partlt laid in slab alongwith the rainfoucement before concreting ,complete with1.5 mm copper earth wire drawn inside the conduit, modular switch and ceiling rose on 3 mm, thick phenolic laminated backelite sheet etc. complete in all respects, as directed including matching colour wash. (As per PWD SOR 2018SI No. - 143 C)
150Wiring point for exhaust fan with 1.5 sq.mm FRLSHPVC insulated multistrand Single Core copper conductor cable in heavy guage PVc Conduit partlt concealed in wall and partlt laid in slab alongwith the rainfoucement before concreting ,complete with 1.5 mm copper earth wire drawn inside the conduit, 15A piano typeswitch and ceiling rose on 3 mm, thick phenolic laminated backelite sheet etc. complete in all respects, as directed including matching colour wash. (As per PWD SOR 2018SI No. - 144 C)
151Wiring point of power plug with 20 a /250 volt flush type moduler switch and 5 pin 20 a/250 volt flush type universal moduler socket switch on concealled M.S. box including supply of all material , labour T&P etc. required for proper completion of work.(As per PWD SOR 2018SI No. - 139 A)
152Supply & wiring of submain with two number 2.5 sq.mm. FR PVC Insulated 1100 V grade multistrand single core copper conductor cable in 20 mm dia heavy duty (2mm thick) PVC conduit with one number 1.5 sq.mm. FR PVC insulated 1100 V grade multistrand single core copper conductor cable as earth continuity wire drawn in conduit. (As per PWD SOR 2018 SI No. - 1307 (C) )
153Supply & wiring of submain with two number 4 sq.mm. FR PVC Insulated 1100 V grade multistrand single core copper conductor cable in 20 mm dia heavy duty (2mm thick) PVC conduit with one number 2.5 sq.mm. multistrand copper conductor cable as earth continuity wire drawn in conduit complete in all respect. (As per PWD SOR 2018SI No. - 221(C) )
154Supply & wiring of submain 4 number 10 sq.mm. FRLSh PVC insulated 1100 V grade multistrand single core copper conductor cable in 32 mm dia heavy duty (2mm thick) PVC conduit with two nos. 6 sq.mm. FR PVC Insulated multistrand copper conductor cable as earth continuity wire drawn in conduit complete in all respects.(As per PWD SOR 2018SI No. - 278(C) )
155Supply & wiring of submain 4 number 16 sq.mm. FRLSh PVC insulated 1100 V grade multistrand single core copper conductor cable in 40 mm dia(2mm thick) PVC conduit partly concealed in wall and partly laid in slab alongwith reinforcement berofoe concreting. with two nos. 10 sq.mm. single core copper conductor cable as earth continuity wire drawn in conduit including matching colour wash etc. complete in all respects. (As per PWD SOR 2018SI No. - 279(C) )
156Supply & Fixing of LED Tube Light with metal heavy duty box type light fitting 2x22 watt suitable for up to 2x22 watt LED polycarbonateTube suitable for both surface & suspendedcomplete in all respect (As per PWD SOR 2018SI No. - 1414 )
157Supply and fixing ofElectronic FanRegulator(Modular) 120-280 VISI marked, on the existingswitch board including making connections,requiredmaterial,labourT&Petc.for proper completion of work to the satisfaction of Engineer Inchargeof work. (PWD SOR 2018SI No. 1203 (C))
158Supply of ceiling fan with fan moter of A.C. permanent insulation ,capicitor rating conforming BEE 5 Star rating and IS:374/79 and also comply with IS:1709/1984 with latest amendent. The rated Voltage 220/240 volts, 50 Hz, 1-ph AC the fan assemble should consists of down rod blades,shackle canopies etc and with double ball bearing system 1200 mm Sweep (As per PWD SOR 2018SI No. - 1501 )
159Supply & fixing of hexagonal/ round G.P. fan box of approved make made up of 1.0 mm thick ISI marked G.P. sheet spot welded four to eight holes of 25.4 mm for pipe entry of the box. Holes should be semi-shuttered type with 0.5 mm GP. sheet made upper & lower cover screwed fitted with 300 mm round zink coted M.S. Bar X 12 mm & brand name should be embossed. Fixing with wiring conduit laid in the R.C.C. roof before concreting alongwith supply of all material, labour, T&P etc. required for proper comletion of the work. (As per PWD SOR 2018SI No. - 1149)
160Supply & fixing of 3 mm thick backlitesheet J,B, cover complete with all material labour T&P as per direction of E/I(MR)
161Supply & fixing of 3 mm thick backlitesheet cover round/hexagonaltype for fan box complete with all material labour T&P as per direction of E/I(MR)
162Erection & testing of Exhaust fan on the existing hole with suitable size rag bolt nut & washer etc. complete in all respects.(As per PWD SOR 2018SI No. - 1120 )
163Erection and testing of ceiling fan and regulator for room height upto 3.5 mts. i/c supply of 3 mm thick G.I. down rod 19 mm dia duly painted, complete in all respects. (As per PWD SOR 2018SI No. - 1116 )
164S/F of Modular blinking plate on existing modular plate and switch box.(As per PWD SOR 2018SI No. - 1034 B )
165S/F of flush/surface mounting 4 ways TPN distribution boards (Legrand Lexic) without MCB with additional metal door complete in all respects. As directed by E/I.(As per PWD SOR 2018SI No. - 1026 A)
166S/F of flush/surface mounting 6 ways TPN distribution boards (Legrand Lexic) without MCB with additional metal door complete in all respects. As directed by E/I.(As per PWD SOR 2018SI No. -1027 A )
167S/F of flush/surface mounting 8 ways TPN distribution boards (Legrand Lexic) without MCB with additional metal door complete in all respects. As directed by E/I.(As per PWD SOR 2018SI No. -1028 A )
168S/F of 240 volts \"L\" series 6-32 amp SP miniature circuit breaker (10 K A) in existing MCB, DB complete with connections as required (Legrand Lexic)(As per PWD SOR 2018SI No. - 1002 )
169S/F of 240 volts \"C\" series 40-63 amp FP miniature circuit breaker (10 K A) in existing MCB, DB complete with connections as required.(As per PWD SOR 2018SI No. - 1020)
170S.I. & Testing of 7.0 m high octagonal G.I. Pole with single arm as per approved sample made from 3 mm sheet steel (Grade S 355 JO) with top diameter as 75 mm and bottom dia as 150 mm and base plate of 240x240x16 mm with suitable slot shaped holes for mounting the same on a shallow foundation, GI weather proof junction box with 16 A SP MCB, loop-in-loop out terminals for 2 nos. 4Cx16 sq.mm YWY cables and 3x2.5 sq.mm copper conductor from junction box to fitting and connected accessories as required etc. Contractor to include the cost of RCC foundaiton for pole as per structural details. (As per PWD SOR 2018SI No. - 642 )
171Supply and fixing of 32 a DP MCB (10ka) c CURVE FOR POLES (As per PWD SOR 2018SI No. - 1005 A )
172Supply and burying of safe Earthing Electrode T-19 (Hot Dip Galvanized), Length 3000mm, outer pipe 50 mm, inner pipe 25, terminal Dia 12mm, outer GI Pipe of 16 swg and inner GI Pipe of 12 swg with Hot Dip Galvanization up to 10 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soile (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30 cm square C.I. frame with hinged cover & masonry housing. ( From electrode terminal to switch board, cost of 25x3mm G.I. strip will be extra) Make: As approved in U.P.P.W.D., & C.P.R.I. Certified. .(P.W.D. S.O.R. 2018S.I. No 725 (D)
173S/burring of 600mmx600mmx3mm copper plate, vertically for Lightining conductor/earthing with its top atleast 3 mts. below ground level complete with 20mm G.I. pipe and funnel for watering and one earthing leads of No.8 SWG copper wire in 15mm dia G.I. Pipe upto switch board (from apron to switch board the cost of G.I. pipe and G.I. wire will be extra) 30 cm. square C.I. frame with hinged cover. masonary housing, alternate layers/of charcoal/coke and salt at least 150 mm thick alround etc. complete in all respects. (S.I.No 705)
174Supply & fixing ofhorizontal air termination (roof conducter)of 25 mm x 3 mm copper strip on G.I. clamps on surface complete in all respects as approved by Engineer -in-charge(As per PWD SOR 2018 SI No. - 711 )
175Supply & fixing ofvertical down conductor of 32 mm x6 mm copper strip etc. on approved clamps on surface for lighting conductor complete in all respects (For two stroreyed buildings) (As per PWD SOR 2018 SI No. - 714A )
176Supply & fixing ofvertical air termination final rod comprising of 300 mm long x25 mm dia copper rod with one poited prong and 100 mm dia x 3 mm thick base plate etc.complete in all respects (As per PWD SOR 2018 SI No. - 712A )
177Supply & fixing oftesting joint of copper strip 32 mm x 6 mm and 150 mm long with tinned of brass bolts and nut etc.complete in all respects (As per PWD SOR 2018 SI No. - 720 )
178Supply & laying of 25mmx3mm G.I. strip for earthing purpose as required complete in all respects(As per PWD SOR 2018 SI No. - 716 )
179Supply & laying of aluminium conductor PVC insulated armoured served sheathed cable 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the engineer in charge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.(As per P.W.D. SOR 501)
18025 sq.mm 3 1/2 core
18110 sq.mm 4 core
18235 sq.mm 3 1/2 core
183Supply & fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, under ground cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth as per direction of Engineer in charge.
18416 sq.mm 3 1/2 core (As per PWD SOR 2018 SI No. - 503 (i) )
18510 sq.mm 3 1/2 core (As per PWD SOR 2018SI No. - 503 (h) )
18625 sq.mm 3 1/2 core (As per PWD SOR 2018SI No. - 503 (j) )
187Supply & fixing of Plain or Pin type copper tin plated cable socket (lug) to the cable leads, insulating with tape and making connection etc. complete in all respect as per dorection of the Engineer-In charge.
18816 sq.mm (As per PWD SOR2018SI No. 504 (d)
18910 sq.mm (As per PWD SOR2018SI No. 504 (c)
19025 sq.mm (As per PWD SOR2018SI No. 504 (e)
191Supply & fixing of surface/flush mounting 4 ways VTPN distribution board with additional door with out MCB complete in all respect. As directed at site by Engineer -in-charge. (S.I.1026 C)
192S&F of 63 amp. TP MCB (10KA) c curve(As per PWD SOR 2018SI No. - 1017 )
193S&F of 40 amp. TP MCB (10KA) c curve(As per PWD SOR 2018SI No. - 1016 )
194Main LT Panel
195Supply & Errection of factory fabricated & wired metal clad and dustand vermin proof floor mounting entreis Electrical control panel with TPN MCCB s(four pole 36 KA with thermal magnatic release) Switches complete and lnstrument chamber etc. complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters (KVA, P.F. K.W etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic aluminium busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCB\"s shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc.The Job includes the grounting of the board as per directions of E/Ich. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6 mm/2 mm. Cubicle type switch board shall be of cat A & B only. (S.I.No.813 e)
196Incoming
197400 Amp 50KA MCCB. 1No.
198Out going
199100 Amp 25 KA MCCB. 3 Nos.
20063 Amp 18 KA MCCB. 2Nos.
20163 Amp 18 KA MCCB. 1 Nos. Spare
202Addition for light / fan points with moduler type switch in place of piono type switch.As per PWD SOR 2018SI No. - 187A)
203Addition for plug points with moduler type switch in place of piono type switch.As per PWD SOR 2018SI No. - 187C )
204Addition for Call bell points with moduler type switch in place of piono type switch.As per PWD SOR 2018SI No. - 187E )
205Addition for HPMV points with moduler type switch in place of piono type switch.As per PWD SOR 2018SI No. - 187D )
206Addition for exhaust points with moduler type switch in place of piono type switch.As per PWD SOR 2018SI No. - 187D )
207Addition for Two way points with moduler type switch in place of piono type switch.As per PWD SOR 2018SI No. - 187B )
208Supplying and fixing following size/modules, GI box along with modular base & cover plate for modular switches in recess etc as required1 or 2 Module
209(75 mm x 75 mm) (DSR no 1.27.1)
210Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc as required.
211Telephone socket outlet (DSR no 1.24.6)
212Supplying and drawing telephone wire following pair 0.5 sqmm FR PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface/recessed steel/PVC conduit as required.
2132 pair (DSR no 1.18.2)
214S/F of 10 pair junction Boxes for floors and building with Krone connectors, with connection and punching of same.
215Providing and laying unplastisized rigid PVC pipe conforming to IS: 13592 type A including jointing, cutting and making good the walls & floors as per requirement.150 mm
216Supply & fixing of door chime on polished MDFEG/Teak ply board including making connections etc, complete in all respect
217Supply & fixing of 16 gauge M.S. drum with luvers duly painted including making hole in the wall for exhaust fan and finising properlycomplete in all respect (S.I.No 1122)
218S/F of Industrial water tight oblong 10 watt LEDbulk head fitting luminaire having die cast housing with driver set confirming to IP 65 and above protection complete in all respect.(1417)
219Supply and laying of 1800 mm x900 mmx12 mm thick chequered rubber matt of tested quality.ing. (1136)
220Supply and erection of AC 230/250 Volts, 50 Hz exhaust fans including providing nuts, bolts, mounting frame and other accessories including connections etc complete as required.a) 300 mm. sweep.
221Supply & Fixing of Desktop or Laptop
222Supply & Fixing of Interactive Projector
223Supply & Fixing of Speakers
224Supply & Fixing of Digital Podium
225Other Accessories (Wire, Cable, Connection and Installation)
226Supply & fixing of fire extinguishers, ABC type 4.00 Kg capacity (ISI marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.
227Supply & fixing of fire extinguishers, CO2 type 4.50 Kg capacity (ISI marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.
228Supply & fixing of RO plant 1000-2000 Litre/hour and all accessories complete.
229Providing & Laying of Interlocking Tile
230G.S.T. Extra as per Applicable

AI Tender Summary

OUR REF NO 36021819
AUTHORITY Government Departments
TENDER VALUE 3.31 Crore
LAST DATE 07-02-2023
Authority
Authority Name Uttar Pradesh Projects Corporation Limited
Work Description Construction And Renovation Of 4 Nos Class Room, 1 Nos Laboratory, Bounadary Wall, Toilets And Water Supply Work, At Rajkiya Inter College Ghorawal District-Sonbhadra.
Basic Detail
Tender No 52/UPPCL/GM-1/E-TENDER/2022-23 Dated-17.01.2023
Bidding Type Tender
Location
City ghorawal
State Uttar Pradesh
Key Dates
Publish Date 01 Feb 2023
Submission Date 07 Feb 2023
Open Date 07 Feb 2023
Finance
Tender Value 3.31 Crore
Tender Fee 17700
EMD 6.64 Lakhs
Exemption Not Available
Document List
8d27f849-3fdb-44aa-bb70-47ad1af333ad.html
BIDDOC52.pdf
BOQ_1272073.xls
Retender52.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Feb 01, 2023
11:30 IST

Tender Published

Tender notice published.

Completed
Feb 07, 2023
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Feb 07, 2023

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

8d27f849-3fdb-44aa-bb70-47ad1af333ad.html

pdf

BIDDOC52.pdf

xls

BOQ_1272073.xls

pdf

Retender52.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders