| 1 | Earth work in excavation by mechanical means (HydraulicExcavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soil asdirected, within a lead of 50 m. All kinds of soil. |
| 2 | Filling available excavatedearth (excluding rock)in trenches,plinth,sidesoffoundationsetc.inlayersnotexceeding20cmin depth,consolidatingeachdepositedlayerbyramming andwatering, leadup to 50 m and lift upto 1.5 m. |
| 3 | SupplyingandfillinginplinthwithJamunasandunderfloorsincluding, watering, ramming consolidating and dressing complete. |
| 4 | Providing and laying in position cement concrete of specified gradeexcludingthe cost of centering and shuttering - Allwork up toplinthlevel 1:4:8(1Cement:4coarsesand:8gradedstoneaggregate 40 mm nominal size). |
| 5 | Providing and laying in position specified grade of reinforcedcement concrete excluding the cost of centring, shuttering,finishing and reinforcement - All work upto plinth level 1:1.5:3(1cement:1.5coarse sand: 3gradedstoneaggregate 20 mm nominal size) |
| 6 | ReinforcementforR.C.C.workincludingstraightening,cutting,bending, placing in position and binding all complete.Mild steel and Medium Tensile steel bars. |
| 7 | Centring and shuttering including strutting,ropping etc. andremoval of form for |
| 8 | Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 9 | Brick work with F.P.S. bricks of class designation 75 in superstructureCement mortar 1:6 (1 cement : 6 coarse sand) |
| 10 | Providing and fixing pressed steel door frames confirming to IS:4351 manufactured from commercial mild steel sheet of 1.25 mm thickness includinghinges jamb, lock jamb, bead and if required angle threshold of mild steel angle ofsection 50x25mm, or base ties of 1.25mm pressed mild steel welded or rigidly fixedtogether by mechanical means, adjustable lugs with split end tail to each jambincluding steel butt hinges 2.5mm thick with mortar guards, lock strike-plate andshock absorbers as specified and applying a coat of approved steel primer afterpre-treatment of the surface as directed by Engineer-in-charge |
| 11 | Profile\"B\" (Single Pattam) |
| 12 | Providing and fixing pressed steel door frames confirming to IS:4351 manufactured from commercial mild steel sheet of 1.25 mm thickness includinghinges jamb, lock jamb, bead and if required angle threshold of mild steel angle ofsection 50x25mm, or base ties of 1.25mm pressed mild steel welded or rigidly fixedtogether by mechanical means, adjustable lugs with split end tail to each jambincluding steel butt hinges 2.5mm thick with mortar guards, lock strike-plate andshock absorbers as specified and applying a coat of approved steel primer afterpre-treatment of the surface as directed by Engineer-in-charge Profile\"E\" (Double Pattam) |
| 13 | Providing and fixing ISI marked flush door shutters conforming toIS: 2202 (Part I) non-decorative type, core of block board construction with frameof 1st class hard wood and well matched commercial 3 ply veneering with verticalgrains or cross bands and face veneers on both faces of shutters 35 mm thick including ISI marked Stainless Steel butt hinges withnecessary screws. |
| 14 | Providing and fixing glazed shutters for doors, windows & clerestory windows using 4 mm thick float glass panes including black enamelled ISImarked M.S. butt hinges with necessary screws30 mm. thick |
| 15 | Providing and fixing 30mm thick wire gauge shutters usinggalvanised M.S. wire gauge of average width of aperture 1.4mm with wire of dia. 0.63mm for doors, windows and clerestory windows including ISI marked StainlessSteel butt hinges with necessary screws (Second class teak wood) |
| 16 | Providing and fixing aluminium handles ISI marked anodised(anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed torequired colour or shade with necessary screws etc. complete : 125 mm |
| 17 | Providing and fixing aluminium hanging floor door stopper ISImarked anodised (anodic coating not less than grade AC 10 as per IS : 1868)transparent or dyed to required colour and shade with necessary screws etc. complete. Single rubber stopper |
| 18 | Steel work welded in built up section/framed work includingcutting, hoisting, fixing in position and applying a priming coat of approved steel primerusing steel etc. as required. Ingratings,frames,guardbar,ladder,railings,brackets,gates and similar works. |
| 19 | Providing and fixing hand rail of approved size by welding etc. tosteel ladder railing, balcony railing and staircase railing including applying a primingcoat of approved steel primer. M.S. tube |
| 20 | 6 mm cement plaster mix 1:3 (1 cement: 3 fine sand) |
| 21 | 12 mm thick cement plaster in 1:6 ( 1 cement and 6 fine sand) mortar including supply of all material , labour and T&P etc. required for proper completion of the work. |
| 22 | 15 mm thick cement plaster in cement mortar 1:6 on Rough face of brick wall including supply of all material , labour and T&P etc. |
| 23 | Marble stone flooring with 18mm thick marble stone (sample ofmarble shall be approved by Engineer-in-charge) over 20 mm (average) thick baseof cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cementslurry including rubbing and polishing complete with Raj nagar Plain |
| 24 | Kota stone slab flooring over 20 mm (average) thick base laid overandjointedwith grey cement slurry mixed with pigment tomatch theshadeoftheslabincludingrubbingandpolishingcompletewith baseofcement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick. |
| 25 | Providing and laying Ceramic glazed floor tiles 300x300 mm(thicknesstobespecifiedbythemanufacturer)of1stquality conformingtoIS:15622 ofapprovedmake in colourssuch asWhite, Ivory,Grey,FumeRedBrown,laidon20mmthickCementMortar1:4(1 Cement:4Coarsesand)includingpointingthejointswithwhitecement andmatching pigment etc., complete. |
| 26 | Marble stone skirting with 18mm thick marble stone (sample ofmarble shall be approved by Engineer-in-charge) over 20 mm (average) thick baseof cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cementslurry including rubbing and polishing complete with Raj nagar Plain |
| 27 | Kotastoneslabs25mmthickinrisersofsteps,skirting, dadoandpillarslaidon12mm(average)thickcementmortar1:3(1 cement3coarse sand) and jointed with grey cementslurry mixed withpigment tomatch the shade of the slabs, including rubbing and polishingcomplete. |
| 28 | ProvidingandfixingIstqualityceramicglazedwalltiles conformingtoIS : 15622 (thicknessto be specified by the manufacture ) ofapprovedmake in all colours, shades except burgundy, bottle green, black ofanysizeas approvedbyEngineer-in-Charge inskirting, risersofstepsanddados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3coarsesand)and jointingwith [email protected] persqm includingpointinginwhitecementmixedwithpigmentofmatching shadecomplete. |
| 29 | White washing with lime to give an even shade: New work (threeor more coats) |
| 30 | Distempering with oil bound washable distemper of approvedbrand and manufacture to give an even shade (New work (two or more coats) over and including priming coatwith cement primer) |
| 31 | Finishing walls with textured exterior paint of required shade Newwork([email protected]/10sqm)over and including basecoatofwater proofing cement paintapplied @ 2.20kg/10 sqm. |
| 32 | PaintingwoodworkwithDeluxeMultiSurfacePaintofrequired shade.Twoor more coat applied @0.90ltr/[email protected]/10sqm ofapproved brand or manufacture |
| 33 | PaintingSteel workwithDeluxeMultiSurface Paintto givean even shade. Two or morecoatapplied @0.90 ltr/10sqmover an under coatof [email protected]/10sqmofapproved brand or manufacture |
| 34 | Sanatory |
| 35 | Providing and fixing watercloset squatting pan(Indian type W.C.pan )with 100mm sand castIronP or S trap, 10 litre lowlevelwhite P.V.C.flushingcisternwithmanuallycontrolleddevice(handlelever)conforming to IS : 7231,with all fittings and fixtures completeincludingcutting and making good the walls and floors wherever required :WhiteVitreouschinaOrissapatternW.C.panofsize580x440mm with integral type foot rests |
| 36 | Providingandfixingwhitevitreouschinapedestaltypewater closet(EuropeantypeW.C.pan)withseatandlid,10litrelow levelwhiteP.V.C.flushingcisternwithmanuallycontrolleddevice(handle lever), |
| 37 | Rangeoftwourinalbasinswith5litrewhiteP.V.C.automatic flushing cistern. |
| 38 | Providingand fixingwashbasinwithC.I.brackets,15mm C.P. brasspillartaps,32mmC.P.brasswasteofstandardpattern, includingpaintingoffittingsandbrackets,cuttingandmakinggood |
| 39 | Providingandfixingwhitevitreouschinalaboratorysinkwith C.I.brackets, C.P. brass chain with rubber plug 40mm C.P brass wasteand40mmC.P.brasstrapwithnecessaryC.P.brassunions completeincluding paintingof fittings and brackets,cuttingandmakinggood thewall wherever required :Size 600x450x200mm |
| 40 | Providing and fixing soil , waste and vent pipes: DSR rate in 30% add |
| 41 | 100 mm dia. |
| 42 | 75 mm dia |
| 43 | Providing and filling the joint with spun yarn cement slurry and cement mortar 1:2 (1cement :2 fine sand) in S.C.I./C.I Pipes: DSR rate in 30% add |
| 44 | 100 mm dia. |
| 45 | 75 mmdia. |
| 46 | Providind and fixing M.S.holder bat clamps of approved design to sand cast iron/cast iron (squn) pipe embedded in and including cement concrete blocks 10x10x10cm of 1:2:4 mix (1cement :2coarse sand :4graded stone aggregate 20mm nominal size ) including cost of cutting holes and making good the walls etc: DSR rate in 30% add |
| 47 | 100 mm dia. |
| 48 | 75 mm |
| 49 | Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. DSR rate in 30% add |
| 50 | 100 mm dia. |
| 51 | 75 mm dia |
| 52 | Providing and fixing 100 mm sand cast iron S&S plain bend of required degree. DSR rate in 30% add |
| 53 | 100 mm dia. |
| 54 | 75 mm dia |
| 55 | Providing and fixing 100 mm sand cast ironS&S heel rest sanitry bend of required degree. DSR rate in 30% add |
| 56 | 100 mm SCI S&S heel rest sanitary bend |
| 57 | 75 mm dia |
| 58 | Providing and fixing single equal plain junction of required degree with access door insertion rubber washer 3 mm thick bolts and nuts complete. DSR rate in 30% add |
| 59 | 100x100x100 mm |
| 60 | Providing and fixing 100 mm sand cast irons&s terminal guard( DSR rate in 30% add) |
| 61 | 100mm |
| 62 | Providing and fixing 100 mm sand cast iron S&S collar ( DSR rate in 30% add) |
| 63 | 100mm |
| 64 | 75mm |
| 65 | Providing and fixing 100 mm M.S stays and clamps for sand cast iron /centrifugally cast (squn) iron pipes of diameter:DSR rate in 30% add |
| 66 | 100 mm dia. |
| 67 | Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors: DSR rate in 30% add |
| 68 | 100 mm inlet and 75 mm outlet SCI tarp |
| 69 | 100 mm inlet and 100 mm outlet SCI tarp |
| 70 | Electricity |
| 71 | WGPVCPT Point wiring in PVC conduit, with piano type switch: Wiring for light point/ fan point/ exhaust fan point/ recessed PVCconduit, with piano type switch, phenolic laminated sheet, suitablesize M.S box and earthing the point with 1.5 sq. mm. FR PVCinsulated copper conductor single core cable etc. as required. |
| 72 | Group B |
| 73 | WGSTLPTTC Twin Control point wiring in PVC conduit, with painotype switch: Wiring for twin control light point with 1.5 sq.mm FR PVC insulatedcopper conductor single core cable in surface/ recessed PVCconduit, 2 way piano type switch, phenolic laminated sheet,suitable size Gl box and earthing the point with 1.5 sq.mm FR PVCinsulated copper conductor single core cable etc. as required. |
| 74 | WGPVCPP2 Power plug wiring in PVC conduit (2x4 sq. mm): Wiring for light/ power plug with 2x4 sq. mm FR PVC insulatedcopper conductor single core cable in surface/ recessed PVCconduit alongwith 1 No 4 sq. mm FR PVC insulated copperconductor single core cable for loop earthing as required. |
| 75 | WGPVCSB Circuit/sub-man wiring in PVC conduit: Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of PVC insulated copper conductor, single core cablein surface/ recessed PVC conduit as required. 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire |
| 76 | LPACCPT S/F light plug point piano type accessories: Supplying and fixing metal box of 150mm x 75mm x 60mm deep(nominal size) on surface or in recess with suitable size of phenoliclaminated sheet cover in front including providing and fixing 3 pin5/6 anos socket outlet and 5/6 amps piano type switch,connection, painting etc. as required. (For light plugs to be used in non residential buildings). |
| 77 | PPACCPT S/F power plug point plano type accessories: Supplying and fixing metal box of 180mm x 100mm x 60mm deep(nominal size) on surface or in recess with suitable size of phenoliclaminated sheet cover in front including providing and fixing 6 pin5/6 & 15/16 amps socket outlet and 15/16 amps piano typeswitch, connection, painting etc. as required. |
| 78 | ITCFFSUR ITC fluorescent fitting directly on surface: Installation, testing and commissioning of pre-wired, fluorescentfitting/ compact fluorescent fitting of all types, complete with allaccessories and tube etc. directly on ceiling / wall, includingconnection with 1.5 sq.mm FR PVC insulated, copper conductor,single core cable and earthing etc. as required. |
| 79 | ITCER S/F resistance type ceiling fan regulator: Insallation, testing and commissioning of resistance type ceilingfan regulator, in existing switch box including connection with 1.5sq. mm FR PVC insulated, copper conductor,single core cable.earthing the regulator etc. as required. |
| 80 | SPMCBDB S/F SP MCB DB: Supplying and fixing following way, single pole and neutral, sheetsteel, MCB distribution board, 240 volts, on surface/ recess,complete with tinned copper busbar, neutral busbar, earth bar, dinbar, detachable gland plate, interconnectios, phosphatized andpowder painted including earthing etc. as required. (But withoutMCB/RCCB/lsolator) 8 way Single door |
| 81 | MCBC S/F \"C\" series, SP MCB Supplying and fixing 5 amps to 32 amps rating, 240 volts, \"C\"series, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete with connections,testing and commissioning etc. as required. Single pole and neutral |
| 82 | Supply of ceiling fans 1400 mm |
| 83 | Supply of regulators |
| 84 | Supply of florocent tube lights 1200 mm |
| 85 | Water Supply |
| 86 | Providing and fixing G.I. pipes complete with G.I. fittings andclamps, including cutting and making good the walls etc. Iinternal work - Exposed onwall 15 mm dia nominal bore |
| 87 | 20 mm dia nominal bore |
| 88 | Providing and fixing G.I. pipes complete with G.I. fittings includingtrenching and refilling etc. (external work) 25 mm dia nominal bore |
| 89 | Providing and fixing brass bib cock of approved quality 15 mm nominal bore. |
| 90 | Providing and fixing brass stop cock of approved quality 15 mm nominal bore. |
| 91 | Providing and fixing gun metal non-return valve of approvedquality (screwed end) 25 mm nominal bore Horizontal |
| 92 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI :12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet, and overflow pipes but without fitting and the base support for tank. |
| 93 | Rain Water Harvesting |
| 94 | Earth work in excavation by mechanical means (HydraulicExcavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soil asdirected, within a lead of 50 m. All kinds of soil. |
| 95 | Filling available excavatedearth (excluding rock)in trenches,plinth,sidesoffoundationsetc.inlayersnotexceeding20cmin depth,consolidatingeachdepositedlayerbyramming andwatering, leadup to 50 m and lift upto 1.5 m. |
| 96 | Providing and laying in position cement concrete of specified gradeexcludingthe cost of centering and shuttering - Allwork up toplinthlevel :1:4:8(1Cement:4coarsesand:8gradedstoneaggregate 40 mm nominal size) |
| 97 | Providing and laying in position cement concrete of specified gradeexcludingthe cost of centering and shuttering - Allwork up toplinthlevel 1:2:4(1Cement:2coarsesand:4gradedstoneaggregate 20 mm nominal size). |
| 98 | Reinforced cement concrete work in walls (any thickness),including attached pilasters, buttresses, plinth and string courses,fillets, columns, pillars, piers,abutments, posts and struts etc. uptofloor five level excluding cost of centring, shuttering, finishing and reinforcement 1:1.5:3(1cement:1.5coarse sand: 3gradedstoneaggregate 20 mm nominal size) |
| 99 | ReinforcementforR.C.C.workincludingstraightening,cutting,bending, placing in position and binding all complete.Mild steel and Medium Tensile steel bars. |
| 100 | Centring and shuttering including strutting,ropping etc. andremoval of form for Suspendedfloors,roofs,landings,balconiesandaccess platform. |
| 101 | Brick work with F.P.S. bricks of class designation 75 in foundationand plinth in (Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 102 | Honey-combbrickwork10/11.4cmthickwithbricksofclassdesignation 75 in cement mortar 1:4 (1 cement : 4 coarse sand). Rs. 277.2X2For 23 cm thick wall |
| 103 | 12 mm thick cement plaster in 1:4 ( 1 cement and 4 fine sand) mortar including supply of all material , labour and T&P etc. required for proper completion of the work. 1:4 (1 cement : 4 fine sand) |
| 104 | Inlet Pipe 100 mm dia |
| 105 | Outlet Pipe 100 mm dia |
| 106 | Providing and fixing on wall face unplasticised Rigid PVC rain waterpipes conforming to IS : 13592 Type A including jointing with seal ringconforming to IS : 110 MM Dia |
| 107 | Constructing masonry chamber 30x30x50 cm, inside with 75 class designation brick work in cement mortar 1:4 (1cement :4 coarse sand ) with C.c 1:2:4 floor over C.C 1:5:10 Finished with a floating coat of neat cement complete . |
| 108 | 599.80 x30% |
| 109 | Supplying and fixing C.I. cover 300x300 mm without frame forgully trap (standard pattern) the weight of cover to be not less than 4.5kg |
| 110 | Drainage |
| 111 | Providing, laying and jointing glazed stoneware pipes grade ‘A’with stiff mixture 100 mm diameter |
| 112 | Providing and laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40 mm nominal size) all round S.W pipe including bed concrete as per standard design: 100 mm diameter S. W. pipe |
| 113 | Providing and fixing square-mouth S.W. gully trap grade ‘A”complete with C.I. With F.P.S Brick class designation 75 |
| 114 | Constructing brick masonry manhole in cement mortar 1:4 ( 1cement : 4 coarse With F.P.S. bricks with class designation 75 |
| 115 | Extra depth for manholes Size 90x80 cm With F.P.S brick class designation 75 |
| 116 | Septic Tank & Sock pit |
| 117 | Excavation in foundation :in ordinary soil including lift up to 1.5 meter (5ft) and lead up to 30 meters (100ft) and including filling , watering and ramming of excavated earth into the the trenches or into the space between the building and the sides of foundatin trenches or into the plinth and removal and disposal of surplus earth as directed by the engineer-in-charge trenches including cost of labour T&P complete. All kinds of soil. |
| 118 | Earth work in excavation by mechanical means (Hydraulicexcavator)/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, for plinth filling including watering remaning and drassing complete. |
| 119 | Providing and laying in position cement concrete of specified gradeexcludingthe cost of centering and shuttering - Allwork up toplinthlevel 1:4:8(1Cement:4coarsesand:8gradedstoneaggregate 40 mm nominal size). |
| 120 | Reinforced cement concrete work in walls (any thickness),including attached pilasters, buttresses, plinth and string courses,fillets, columns, pillars, piers,abutments, posts and struts etc. uptofloor five level excluding cost of centring, shuttering, finishing and reinforcement 1:1.5:3(1cement:1.5coarse sand: 3gradedstoneaggregate 20 mm nominal size) |
| 121 | ReinforcementforR.C.C.workincludingstraightening,cutting,bending, placing in position and binding all complete.Mild steel and Medium Tensile steel bars. |
| 122 | Centring and shuttering including strutting,ropping etc. andremoval of form for Suspendedfloors,roofs,landings,balconiesandaccess platform. |
| 123 | Brick work with F.P.S. bricks of class designation 75 in foundationand plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 124 | Honey-combbrickwork10/11.4cmthickwithbricksofclassdesignation 75 in cement mortar 1:4 (1 cement : 4 coarse sand). |
| 125 | S/Filling brick ballast 50 mm size |
| 126 | 12 mm cement plaster finished with a floating coat of neat cementof mix 1:3 (1 cement : 3 fine sand) |
| 127 | Cement concrete flooring 1:2:4 (1 cement: 2 coarse sand : 4graded stone aggregate) finished with a floating coat of neat cement including cementslurry, but excluding the cost of nosing of steps etc. complete. 40mm thick with 20mm nominal size stone aggregate. |
| 128 | Manhole cover |
| 129 | Inlet Pipe 100 mm dia |
| 130 | Outlet Pipe 100 mm dia |