Tender For Construction And Renovation Of Ib Narasinghpur For The Year 2022-23
Tender Value
25.07 Lakhs
Estimated cost
Bid Submission
15 Feb 2023
0 days left
EMD
26000
Bank guarantee accepted
Document Fee
6000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
narasinghpur → Odisha
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Construction And Renovation Of Ib Narasinghpur For The Year 2022-23
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in excavation of foundation trenches in all kinds of soil upto the required depth including moorum, stoney earth and earth mixed with boulders except sheet rocks and boulders requiring blasting including dressing, leveling the bed and depositing the excavated materials away from work site with initial leads and lifts, T&P shoring, shuttering and dewatering if required etc, complete as directed by the Engineer-in–charge. |
| 2 | Supplying filling in foundation, plinth & core with sand in layers not exceeding 150mm thick including watering, ramming, cost, conveyance, royalty and taxes of all materials and cost of all labour T&P required for the work etc. complete (measurement will be taken on finished compacted section only). |
| 3 | Cement concrete (1:3:6) in foundation and floors using 4cm(1½”) size hard crusher broken granite stone metal of approved quality and from approved quarry including lowering, laying concrete watering, curing etc, complete to required levels laid in layers not exceeding 0’-6” thick including cost, conveyances, royalties, taxes of all materials and cost of all labour with T&P required for the work etc, complete as per specification & direction of the Engineer-in-charge. |
| 4 | RCC M-20 usingblack hard granite crusher broken chips of 10mm to 20mm size (10mm 40% and 20mm 60% ) of approaved qualityfrom approved quarry to achieve the minimum compressive strength of 200kg/cm2 250kg/cm2, 3.00 kg/cm2 of 150mm size cubes on 28 days test confirming to codal provision including hoisting lowering and laying concrete in layers not exceeding 15cm thick compacting in vibrators and watering for 28 days including centering shuttering from works finishing the exposed surface smooth providing grooves where necessary including cost conveyance royalty taxes of all materials with all leads and lifts and cost of all labour T&P mechineries required for the work de-watering if necessary compalete in all respect as directed by Engineer-in-charge including dismantling the centering and shuttering but excluding cost conveaynce of MS rod or tor steel & bind wire and labour charges for strengthening cutting beinding binding wilding and tying the grills etc hoisting and placing in positing (to be paid separetely for RCC work)A.COLUMN BASE FOOTING |
| 5 | B. COLUMN SUPERSTRUCTURE (GROUND FLOOR) |
| 6 | 1ST FLOOR |
| 7 | D. LINTEL BAND |
| 8 | E. FLOOR BEAM |
| 9 | ROOF SLAB |
| 10 | Straightening the coiled or bent up M.S. rod / HYSD bars confirming to Gr. S 240 or S 415, cutting bending binding lapping placing welding etc. (Confirming to ISI specification) and jointing if necessary by lapping and tying the grills and placing in position as required for RCC work as per approved design hoisting lowering and laying in position including cost conveyance & taxes of M.S. rod / tor steel and binding wire of 18 to 20 gauge (as approved by the deptt.) weight of over lapping, coping, welded joints, spear bar, chair, stage, hanger andbinding wires shall not be considered for payment at all. Standard co-efficient of different size of the steel shall be considered. Welding & lapping should be confirming to relevant clause of IRC 1987. |
| 11 | Fly ash Brick masonry using Fly ashBricks in SUPERSTRUCTURE having crushing strength not less than 75Kg/sqcm in cement mortar (1:6) after immersing the bricks for six hours in water before useincluding splays, cutting, circular moulding, corbelling, champhering and similar such type of works,scaffolding, watering, curing, including cost, conveyances, royalties, taxes of all materials and cost of all labour with T&P required for the work etc. complete as per specification & direction of Engineer-in-charge. |
| 12 | Providing 12mm thick cement plaster in cement mortar (1:6)finished smooth to inside rough surface of brick walls after racking out joints, scrapping & cleaning the surface, watering, curing, scaffolding, screening sand etc. complete with cost, conveyances, royalties, taxes of all materials and cost of all labour with T&P, sundries required for the work etc. complete as per specification & direction of Engineer-in-charge. |
| 13 | Providing 16mm thick cement plaster in cement mortar (1:6)finished smooth to inside rough surface of brick walls after racking out joints, scrapping & cleaning the surface & finishing the plaster surface smoothwatering, curing, scaffolding, screening sand etc. complete with cost, conveyances, royalties, taxes of all materials and cost of all labour with T&P, sundries required for the work etc. complete as per specification & direction of Engineer-in-charge. |
| 14 | Providing 6mm thick cement plaster in cement mortar (1:4)finished smooth in ceiling & finishing the plaster surface smooth using wooden float only to proper plumbs & level and making necessary grooves, beads & drip course to give required ornamental finish as per drawing, watering, curing, scaffolding, screening sand etc. complete with cost, conveyances, royalties, taxes of all materials and cost of all labour with T&P, sundries required for the work etc. complete as per specification & direction of Engineer-in-charge. |
| 15 | Supplying fitting and fixing vitrified tile(SOMANY, KAJARIA, JOHNSON) in floors of size 600mmx600mm of approved make conforming to IS 13755 with application of polymer modified quick set cement based water resistant adhesive conforming to IS 15477 of 3mm thick bed and filling joints with white cement of approved quality including cost of all materials labour T&P etc required for the work all complete as per direction of Engineer-in-charge |
| 16 | Supplying fitting and fixing vitrified tile(SOMANY, KAJARIA, JOHNSON) in dadooof 25MM thick of approved make conforming to IS 13755 with application of polymer modified quick set cement based water resistant adhesive conforming to IS 15477 of 3mm thick bed and filling joints with white cement of approved quality including cost of all materials labour T&P etc required for the work all complete as per direction of Engineer-in-charge |
| 17 | Providing priming two coatwith approved primerincluding cost, conveyance, taxes, cost of all labour as per direction and specification of Engineer in charge |
| 18 | Finishing the wall surface with Acrylic Wall putty (water based) of approved make and finished smooth & even surface to receive painting including cost of scaffolding staging charges with cost, conveyances, taxes of all materials, cost of labour, T&P required for the work etc. complete for all floors as per specification & direction of the Engineer-in-charge. |
| 19 | Finishing wall surface two coats of plastic emulsion paint over a coat of water bound primer to given an even shape of the surface including cleaning the surface with sand papering and using primer & paint of approved shade incluidng cost, conveyance, taxes, royalities, cost of all labour, T&P etc. complete as per direction and specification of Engineer-in-charge. |
| 20 | Finishing wall surface two coats of weather coat over a coat of water bound cement primer with cost, conveyance, taxes, royalities, cost of all labour, T&P etc. complete as per direction and specification of Engineer-in-charge. |
| 21 | Supplying, fitting & fixing in all floors of M.S. grills, grill gates, M.S. gates, garage door, collapsible gates with top and bottom rails, steel windows, crital frames for windows, balustrades of stair case and parapet railing made out of M.S Square bar/ flat as per approved drawing and design including making holes in walls and R.C.C structure, wood work etc., and making good to the damages to walls with cement concrete (1:2:4) with hard crusher broken granite stone chips of 12mm to 20mm size (20mm size not to exceed 25%) of approved quality with cost of all materials, labour, cost of welding, all T&P, sundries etc. complete in all respect as per specification & direction of the EI.C. (Screws & other hardware required materials to be used in the work shall be of approved quality & specification & shall have to be supplied by the contractor at his own cost.) |
| 22 | Supplying fitting and fixing of 32mm flush door shutters with flush door block \"A\" premium 32mm thick both side teak (Green Play/Allwin) both side laminated with 4mm thick veener board (Teak Heritage) (Archid ply/ Green ply) by using adhesives, with all labour iron fitting and wooden hinged cleats etc fitted and fixed complete in all respect including cost of iron fitting alluminium fittings all labour T&P etc as per specification approved by the Department and as per direction of the engineer-in-charge |
| 23 | Supplying and fiting fixing of Un-plasticised Poly Vinyl Chioide (UPVC) (FENESTA/NCL VERA LTD casement Door -60- series duly manufactured using UPVP reinforeced profiles of 60mmx55mmx25mm for outer frames 102mmx80mm for casement Door such profile and 74mmx60mmx2.5mm mullion profile capable of mouting single glazing system structurally reinforced with hot dip galvanised up to 50 microns of minimum thicknessof 2.0 mm prefabricated and welded through fusion welding the doorsuch shall be fited with 12mm WPC board of reenply make duly fixed with EPDM weathering seal resistant accessories likecliping ocking system made of aluminium 1 No per set of sashes and the systemis to be installed at the side using anchor fasteners silicone rubber sealant, easy glazing/egiazing at sideetc inlcuidng cost and conveyance of all materailsconfirmingto ASTM D638-14EN-477-95 and the applicable codes and standards. |
| 24 | Providing and fixing of WPC solid door frame (4x2.5 solid frame single patti with installation charges with cost of labour, conveyance, taxes, loading, unloading T&P etc. all complete as per the direction of Engineer in charge. |
| 25 | 2.5cm thick grading concrete (1:2:2) using 6mm thick crusher broken hard granite chips with cost, conveyances, royalties, taxes of all materials and cost of all labour with T&P required for the work etc. complete as per specification & direction of Engineer-in-charge |
| 26 | E.I. work--Recessed wiring to light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non-metalic PVC flexible conduit with 5Amp, 250 V modular type switch ISI marked and ceiling rose ISI marked mounted on modular GI box with modular base & cover of suitable size , MS box with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as arth wire including all accesories and connection as per direction of Engineer in Charge. ( Make of wire- Finolex/ L&T / Anchor / Havels or eq. model ) (Make of switch-Anchor Roma/Legrand arteor/Panasonic Visionor eq. model)Group-A L.P-7 |
| 27 | Group-B L.P-15 F.P-7 |
| 28 | Group-C L.P-13E.F.P-2 C.B.P-1 |
| 29 | Separate Point wiring for 5 / 6 amp modularsocket outlet with 2 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked in recess 20 mm dia non-metalic PVC flexible conduit with modular one way type switch ,phenolic laminated sheet suitable size ISI marked MS box and earthing point with 1 x 1.5 sq.mm FR PVCinsulated single core multistrand copper conductor for loop earthing etc. as required. ( Make of wire- Finolex / L&T / Havels/Anchor) (Make of switch-Anchor Roma/Legrand arteor/Panasonic Vision or eq. model) |
| 30 | Supply and fixing of 5Amp modular switch and socket on existing board (Make of switch-Anchor Roma/Legrand arteor/Panasonic Vision or eq. model) |
| 31 | Supplying and fixing of metal box of Modular G.I box for 6 module 18 SWG on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 15 / 16 amps modular socket outlet and 15 / 16 amps modulartype switch, connection, painting etc as required.( Make of wire-Anchor/ Finolex / L&T / Havels) (Make of switch-Anchor Roma/Legrand arteor/Panasonic Vision or eq. model) |
| 32 | Supplying and fixing of computer board consisting 3 nos 6 Amp Plug, 3 nos switch, 1 No 15 Amp Switch & 1 No 15 Amp Socket Modular type on modular box, base & cover with all connections ( Make of wire-Anchor/Finolex / L&T / Havelsor eq. model ) |
| 33 | S/F of A.C point consisting ofstatorwith 1 No 15 Amp Socket Modular type on modular box, base & cover with all connections completein all respect as per direction of Engineer in charge (Cona / Anchor / Havels or eq. model) |
| 34 | Recessed wiring to submain in the following sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked conforming to IS-694/1990 in the following mm dia non-metallic heavy duty flexible conduit 1.6 mm thick along with the following sq.mm FR PVC insulatedsingle core multistrand copper conductoras earth wire as required.(Make of wire-Finolex/L&T/Anchor/Havells/V-Guard//HPL)2 X 1.5 sq.mm +1 X 1.5 sq.mm in 20 mm dia |
| 35 | 2 X 2.5 sq.mm +1 X 1.5 sq.mm-do- |
| 36 | 2 X 4 sq.mm +1 X 1.5 sq.mm -do- |
| 37 | 2 X 6 sq.mm +1 X 2.5 sq.mm in 25mm dia |
| 38 | 2 X 10 sq.mm + 1 X 4 sq.mm-do- |
| 39 | Supply and drawing of following sizes FR PVC insulated single core multistrand copper conductor in existingsurface/recessed/STEEL /PVC conduit as required for Inverter wiring. 1 X 1.5sqmm |
| 40 | Supply and fixing of 15 Amp Top including all acessories and connection for Inverter ( Make : Cona/Anchor/Legrand/Havels) |
| 41 | Supply and fixing of following way single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) (Make- Legrand /L&T/Schneider /Siemens or eq. model) 8way, Double door |
| 42 | Supply and fixing of 5Amp to 32A rating 240 V/415 V \"B\" series MCB suitable for lighting and other loads of the following poles in the exiting MCB DB ISI marked complete with connections testing and commissioning etc. (Make- Legrand DMX 3 /L&T/Siemens or eq. model) Single pole (SP) |
| 43 | 40 Amp DP MCB |
| 44 | Supply ,installation, testing and commissioning of main switches (IS 13940 part-3/1993) of following capacity on existing surface / wall mounting and completer with fuse links, interconnections, earthing including metal box & B.K cover etc as required as per direction of Engineer-in-charge. (Make-Seimens/ HPL/ Anchor/ L&T/Havells) 63Amp ICDP main switches |
| 45 | Supply and fixing of modularType fan regulator (Make-Roma/Legrand or eq model) |
| 46 | S/F of 48\" size A.C Ceiling fan with all accesories and connection (Make- Usha Striker/Usha allure /crompton decora /crompton jura /polycab vital or eq. model ) |
| 47 | Supply & Fixing of 12 inchHeavy duty Exahust Fan with wall cutting,plastring, painting with all connection complete in all respect as per direction of Engineer in charge(Make- Havells/Almonard / Usha or eq. model) |
| 48 | Supplying and fixing of Call Bell / Buzzer ISI marked suitable for DC /AC single phase 230 volts complete as required. (make-Cona/Anchor/Crompton or eq. model) |
| 49 | S/F of Bakelite angle holder/batten holder of ISI marked including connection etc as required . |
| 50 | S/F of 9Watt LED bulb (Make-Havells/Philips/Crompton or eq. model) |
| 51 | Supply and fixing of 18watt LED TUBE LIGHTwith very high efficiency suited for installation in existing G5 lamp holders toglare give free light . (Make:Philips/Havells/Crompton or eq. model) |
| 52 | Supply and fixing ofRecessed/surfacedownlight fitting 15/18watt squre/roundprofile with optimized heat sink for efficeint heat disspation and separate replaceable electronic driver 15/18W LED 3000K(Philips/Havells or eq. model) |
| 53 | S/F of 90wattLEDStreet Light New generation energy saving & environmental friendly long life versatile pressure die-cast aluminium IP66 roadway luminaire with high power LEDs as light source and electronic drive including G.I bracket ,M.S clamp ,Anchor fastner withall acccessories and connection.(Make:Philips/Havells/Crompton or eq. model) |
| 54 | Supply and fixing of Special Copper plate earthing600 mm X 600 mm X 3.15 mm thick ISI marked including accessories and providing 40mm dia 3mtr long G.I pipe, reveting,sweating and solding of copper tape with cover plate having locking arrangement including excavation of rock pit of size 3\"x3\"x10\" depth, refilling of sand & soft soil and watering the pipe with filling of charcoal and salt etc. as required as per direction of Engineer-in-Charge. |
| 55 | Supplying and laying 25 mm x 5 mm copper strip on surface or in recess for connection etc as |
| 56 | Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor CPVC pipesconforming to IS:15778 having thermal stability for hot and cold water supply, including all CPVC plain and brassthreaded fittings including fixing the pipe with clamps at 1.00. spacing. This includes Jointing of pipes & fittings with one step CPVC solvent cement and testing of Jointsall complete as per specification and direction of the Engineer in charge. 20mm dia CPVC pipe In firstfloor |
| 57 | 25mm dia CPVC pipe |
| 58 | Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor pvc pipesconforming to ASTM-D-1785/89 (Sch-80) and pipe fittings of the following nominal bore with clamps including making good the wall, ceilingand floor all complete as per specification and direction of the Engineer in charge.In First Floor 25mm dia PVC ASTM pipe (sch-80) |
| 59 | 32mm dia PVC ASTM pipe (sch-80) |
| 60 | Supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking GI pipes and fittings/ PVC pipes and fittings etc all complete as per PH specification and direction of the Engineer in charge.250mmthick wall |
| 61 | Supplying all materials, labour, T&P and cutting hole in R.C.C floors, roofs, etc upto 19 cm thick for passing GI pipes / PVC pipes and fittings etc and repairing the holes after insertion of pipes etc with cement concrete (1:2:4) including finishing complete so as to make it leak proof as per direction of theEngineer in charge.In ground floor |
| 62 | Supplying allmaterials, labour, T&P and cutting grooves in pucca floors and walls for takingGI/ PVC pipes and making good the damages as per the direction of the Engineer in charge.In firstfloor |
| 63 | Supplying all materials, labour, T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all jointing materials complete as per specification and direction of the Engineer in charge.15mm dia CP two way bib cock (Con-CHR-041KN Jaquar make) |
| 64 | 15 mm dia CP long body Bib cock(Con-CHR-107KN Jaquar make) |
| 65 | 15mm dia C.P. wall mixture 3-in-one System (Jaquar make with provision for over head ShowerFLR-ANQ-5281N |
| 66 | 15mm dia C.P Telephonic Shower |
| 67 | 15mm dia CP angle stop cock(Con -CHR-053KN Jaquar make) |
| 68 | 20mm dia CP concealed stop cock(Con-CHR-083KN Jaquar make ) |
| 69 | Auto closing urinal flush valve(Jaquar make)-PRS-ACR - 073 |
| 70 | 15mm dia C.P. Health foucet(ALD-CHR-573 Jaquar make) |
| 71 | 15mm dia C.P. Pillar cock(Con-CHR-011KN Jaquar make) |
| 72 | 15mm dia pvc connection pipe |
| 73 | 15mm dia urinal spreader |
| 74 | 32mm dia C.P. dome waste |
| 75 | 15mm dia brass threaded tee (Ashirvad make ) |
| 76 | 15mm dia brass threaded El-bow (Ashirvad make ) |
| 77 | 25mm dia brass or gun metal fullway valve(Shakti Make) IS:778 class-I |
| 78 | 32mm dia brass or gun metal fullway valve(Shakti Make) IS:778 class-I |
| 79 | 15mm dia C.P. Flange |
| 80 | 15mm dia C.P. Extension piece |
| 81 | 600mm long C.P. towel rail ( Jaquar make) ACN -CHR-1111NM |
| 82 | C.P. towel Ring (Jaquar make) ACN-BPM-1121N |
| 83 | C.P. Soap Dish Holder ( Jaquar make ) ACN-CHR-1131N |
| 84 | Bottle trap (with internal partition ) 32 Jaquar make -ALD- MCH- 769L250x190 |
| 85 | Single lever Basin mixture (FLR-SSF-5051B Jaquar Make) |
| 86 | Supplying all materials, labour, T&P and fitting and fixing CP shower with 15mm or 20mm inlet with CP shower arm including polishing all complete as per specification and direction of the Engineer in charge 15mm dia CP revolving shower ( Plaza make ) |
| 87 | Supplying all materials, labour, T&P and fitting and fixing10 litres capacity low level flushing cistern with a pair of cast iron or M.S brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle, unions and couplings for connection with inlet, outlet and overflow pipes,32mm dia CP flush bend,15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connecting the inlet pipe with supply main etc all complete as per specification and direction of the Engineer in charge Slim Concealed Cistern (Jaquar make- JCS-WHT-2400FS |
| 88 | Body SHR 135 x 135mm (ABS Chrome Plated Face BSA-ABR-70071(Jaquar make ) |
| 89 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No. 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricantby non-heat application method/as per manufacturer’s specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the Engineer in charge In ground floor. 110mm dia U-PVC SWR pipe(Ashirbad / Supreeme ) |
| 90 | 110mmU-PVC door Cross Tee |
| 91 | 110mm U-PVC door tee |
| 92 | 110mm U-PVC door bend |
| 93 | 110mm U-PVC plain bend |
| 94 | 110mm U-PVC Plain tee |
| 95 | 110mm dia U-PVC Plain Shoe Bend |
| 96 | 110mm dia U-PVC offset with out ear |
| 97 | 110mm dia U-PVC cowl |
| 98 | 125mm dia CP grating |
| 99 | 110mm dia PVC SWR Clamp/Clip. |
| 100 | Supplying all materials, labour, T&P and cutting holes through existing brick or laterite masonry wall for taking HCI pipes and fittings including making good the damages etc all completeas per PH specification and direction of the Engineer in charge 250mm to 375mmthick wall |
| 101 | Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet(European type W.C pan) with integral ‘P’or ‘S’ trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1), fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing etc all complete as per specification and direction of the Engineer in charge. (a)EWC Atlanta (Hindware Make -CatNo 92098 and 92129Star white |
| 102 | Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet(European type W.C pan) with integral ‘P’or ‘S’ trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1), fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing etc all complete as per specification and direction of the Engineer in charge. WALL HUNG WC WITH UF SOFT CLOSE SEAT COVER (Jaquar make -VGS-WHT-81951 |
| 103 | Supplying all materials, labour, T&P and fixing bowl pattern urinal of the following sizes including connecting the urinal with 32mm dia pvc waste pipe 910mm long by means of white lead mixed with chopped hemp, fixing 32mm dia CP dome waste, 15mm dia CP spreader including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc all complete as per specification and direction of the Engineer in charge.(a)Half stall urinal (Parryware /Hindware make) Stall urinal (Parryware /Hindware make) |
| 104 | Supplying all materials, labour, T&P and fixing wash kitchen sink/laboratory sink with outlet at end and weir overflow including fitting and fixing a pair of cast iron or MS brackets painted white, fixing 50mm/40mm dia CP brass waste, fixing 50mm/40mm dia PVC waste pipe 910mm long with supply of wooden plugs, screws and cement etc including cutting holes in walls and making good the damages etc all complete as per specification and direction of the Engineer in charge . 600x450x250 mm stainless Steelkitchen sink-glossy-IS: 13983-1994(jayna make ) |
| 105 | Supplying all materials, labour, T&P and fixing wash basins with hole for pillar taps with cast iron or M S brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered ‘Hot’ and ‘Cold’ with long screws, shanks and back nuts of 15mm dia nominal bore, fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste,etc all complete as per specification and direction of the Engineer in charge. Half Pedestal Wash hand basin (Hind ware make -CatNo-91014-Ped-91109 |
| 106 | Supplying all materials, labour, T&P and fixing mirror of superior glass mounted minimum 5mm thickon 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification an direction of the Engineer in charge .600mmx450mm size B.E mirror x minimum 5mm thick(Design Mirror ) |
| 107 | Supplying all materials, labour, T&P and fixing standard sized glass-shelf with CP brass brackets and guard rails complete fixed to wooden plugs with CP screws as per specification and direction of the Engineer in chargeGlass shelf with CP guard rails |
| 108 | Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12mm size hard broken granite chips including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge. In First floor |
| 109 | Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In first floor |
| 110 | Supplying all materials, labour, T&P and providing ceramic tiles in floors, treads and landing on 25mm thick bed of cement mortar 1:1 (1 cement:1 sand) joined with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in charge. 60 cm. x 60 cm. Kajaria / Somany / Johnson to be pree approved .Infirst floor |
| 111 | Supplying all materials, labour, T&P and fixing porcelain glazed tiles in dados skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in charge.60cm. x 30cm. Kajaria / Somany / Johnson to be pree approved .In firstfloor |
| 112 | Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork with cement punning for skirting including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge InIst floor |
| 113 | Supplying all materials, labour, T&P and filling in sunken floor in toilets with cinter (light weight slag) well watered and rammed include conveyance of all materials to worksite payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge. in First Floor |
| 114 | Supply of all materials & laying the waterproofing material of Dr.Fixit torch shield P3160(3mm)with its primer 2 coats or equivalent water proofing material after drying cleaning the concrete surface over the concrete floor/roof/ balcony/sunken and dado upto 1\"6\" in wall including cleaning,applying and mending as per specification including cost, conveyance, taxes, royalities of all materials to work site etc.all complete as per the direction of the Engineer-in-charge. in First Floor |
| 115 | Supplying all materials, labour, T&P and providing brick work with Fly Ash bricks having crushing strength not less than 75kg/cm² with dimensional tolerance± 8 percent in cement mortar (1:4) including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In First floor |
| 116 | Supplying and fitting-fixing of Un-plasticised Poly Vinyl Chloride (UPVC) (FENESTA / NCL VEKA LTD) Casement ToiletDoor – 60- Series duly manufactured using UPVC reinforced profiles of 60 mm x 55 mmx2.5 mm for outer frames, 102 mm x 60 mm x 2.25 mm for casement Door Sash Profile and 74 mm x 60 mm x 2.5mm mullion profile capable of mounting single glazing system, structurally reinforced with hot dip galvanised up to 50 microns of minimum thickness of 2.0 mm prefabricated & welded through fusion welding.The Door sash shall be fitted with 12mm thick WPC Board of Greenply make duly fixed with EPDM weathering seal resistantaccessories like Bathroom locking system made of aluminium 1 No., per set of sashes and the system is to be installed at the site using anchor fasteners, silicon rubber sealant, easy glazing/ deglazing at site etc., including cost and conveyance of all materials, accessories, labour charges. The materials and product confirming to ASTM D 638-14, EN-477-95 and other applicable codes and standards. |
| 117 | EXTERNAL P.H. WORK Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized PVC pipes conforming to IS: 4985/2000 of the following outside dia for class–3(0.60mpa) including jointing with supply of approved solvent cement by non-heat application method/as per manufacturer’s specification, providing and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the Type C-1 standard bedding surrounding or encasingincluding concrete for bedding and curing etc all complete as per PH specification and direction of the Engineer in charge.110mm dia |
| 118 | Supplying all materials, labour, T&P and constructing gully trap chamber of the following inside size with 8cm thick R.C.C precast cover slab in cement concrete (1:2:4) mix using 12mm size h.g chips, foundation concrete (1:4:8) using 40mm size hard granite metal on bed and around trap, KB brickwork in cement mortar (1:6) in F&P and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap,150mmx150mm size CI grating etc all complete as per approved drawing, specification and direction of the Engineer in charge.Inside size 250mmx250mm |
| 119 | Supplying all materials, labour, T&P and constructing inspection chamber of the following sizewith cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class fly ashbrickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips, 12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, RCC cover slab in (1:1.5:3) using 12mm size h.g chips with RCPC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. Inside size 760mmx760mmx460mm |
| 120 | Dismantling and removing old tiled cladding from walls including racking out joints 12mm deep, stacking the useful materials for reuse and removing the debris within 50 m lead etc all complete as per specification and direction of the Engineer in charge |
| 121 | Dismantling and removing old tiled flooring including removing the old base and stacking the useful materials for reuse and removing the debris within 50 m lead etc all complete as per specification and direction of the Engineer in charge In ground floor |
| 122 | Dismantling and removing old lime or cement plaster from walls including racking out joints 12mm deep and removing the debris within 50 m lead etc all complete as per specification and direction of the Engineer in charge |
| 123 | Supplying all materials,labour,T&P and dismantling thedamaged squatting type water closet and urinal plates etc and mending good the damages to the floors and removing the debris at a safe distance as per direction of the Engineer in charge 500mm size Orissa pan |
| 124 | Basin |
| 125 | Cistern |
| 126 | Urinal |
| 127 | Supplying Un-Skilled Labour for Disposing of Dismantled Materials at a Suitable Place etc all complete as per direction of the Engineer -In-Charge. Unskilled Labour. |
AI Tender Summary
Tender Timeline
Feb 01, 2023
11:30 IST
Tender Published
Tender notice published.
CompletedFeb 15, 2023
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedFeb 16, 2023
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender