Repair/Maintenance And Restringing Of Lt Distribution Over Head Lines, Replacement Of Unserviceable Acsr Conductor, Unsv Poles, Lt Feeder Pillar Box, Apfc Panel, Voltage Stabilizer, Ug Cable, Earthing And Other Allied Misc Connected Work At Ascone Node An, barmer-Rajasthan

Military Engineer Services-MES has published Repair/Maintenance And Restringing Of Lt Distribution Over Head Lines, Replacement Of Unserviceable Acsr Conductor, Unsv Poles, Lt Feeder Pillar Box, Apfc Panel, Voltage Stabilizer, Ug Cable, Earthing And Other Allied Misc Connected Work At Ascone Node An. Submission Date for this Tender is 28-02-2023. Electrification Work Tenders in barmer Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

36011571
Corrigendum : Repair/Maintenance And Restringing Of Lt Distribution Over Head Lines, Replacement Of Unserviceable Acsr Conductor, Unsv Poles, Lt Feeder Pillar Box, Apfc Panel, Voltage Stabilizer, Ug Cable, Earthing And Other Allied Misc Connected Work At Ascone Node An
Open Tender
Indian
Rajasthan
barmer
28-02-2023

Tender Details

Repair / Maintenance And Restringing Of Lt Distribution Over Head Lines, Replacement Of Unserviceable Acsr Conductor, Unsv Poles, Lt Feeder Pillar Box, Apfc Panel, Voltage Stabilizer, Ug Cable, Earthing And Other Allied Misc Connected Work At Ascone Node And Zone ‘B’ Jalipa Mil Stn Under Ge ( A ) Barmer

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 04-Feb-2023 CORRIGENDUM BOQ 21-02-2023
2 21-Feb-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 28-02-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 30000.0 /-
Tender Value
INR 15 Lakhs /-

BOQ Items

Name of Work : REPAIR/MAINTENANCE AND RESTRINGING OF LT DISTRIBUTION OVER HEAD LINES, REPLACEMENT OF UNSERVICEABLE ACSR CONDUCTOR, UNSV POLES, LT FEEDER PILLAR BOX, APFC PANEL, VOLTAGE STABILIZER, UG CABLE, EARTHING AND OTHER ALLIED MISC CONNECTED WORK AT ASCONE NODE AND ZONE ‘B’ JALIPA MIL STN UNDER GE (A) BARMER
Sl. No. Item Description
1Excavating in trenches n. exc 1.5m wide and not e. 1.5m in depth for foundation of poles, laying UG cables, etc and getting out in soft/loose soil complete all as specified and directed.
2Removing excavated material not exc. 50 m and depositing where directed at a level not exc 1.5 m above the starting point in soft / loose soil complete all as specified and directed.
3Returning filling including spreading levelling, watering and well ramming in layers not exceeding 25cm in soft/loose soil complete all as specified and directed.
4M&L for boring/drilling by machines/manual horizontally under the road in any type of soil without cuttiing/disturbing the existing road and inserting GI pipe of any size for drawing the cable complete all as specified and directed.(GI pipe shall be measured and paid seperately.
5Material and labour for sand cushioning for under ground cables, spread in trenches, river sand including cleaning, spreading levelling, punning for laying/cushioning of cable all directed. with layer of 8 cm deep before laying cable and 15 cm depth after laying and stretching the cable complete all as specified and directed.Note: For the Purpose of payment puned thickness shall be measured.
6Material & labour for supplying and laying un-reinforced precast concrete cable cover , class LV, type 1 flat. Size 250mm X 150 mm X 40 mm and abutting each other with gap between adjacent precast concrete cable cover not exceeding 10 mm punned sand over underground cables for protection.
7M&L for galvanised steel tube 50mm bore (light grade) layingin road/drain crossingfor cable protection pipecomplete all as specified and directed. .
8M&L for galvanised steel tube 50mm bore (light grade) fixed to pole/wall/floorfor cable protection pipe includingclamp of MS flat of size 50x5mm and nut, bolt & washers of size 50x12mm for clamping of cable protection pipe with wall/pole as where required complete all as specified and directed.
9M&L for PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in foundation filling & mass concrete for sub base of poles complete all as specified and directed.
10M&L cement concrete 1:3:6, type C-2, (using 40 mm graded stone aggregate) for foundation of poles, stays, etc including form work as required/ordered complete all as specified and directed.
11M&L cement concrete 1:3:6 type C1 (using 20 mm graded stone aggregate) as in coping of poles, padestal, etc including necessary form work etc complete all as specified and directed.
12Excavation in post holes (or similar holes) each not exc 0.5 cum getting out , returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in hard/dense soil complete all as specified and directed.
13Supply and laying, XLPE insulated, armoured, heavy duty electric UG cables withaluminium conductor 1100 volts grade complete including porviding lugs as required complete all as specified and directed for cross-sectional area 10 sqmm 2 core.
14All as per item No 13here in before but of size 10 Sqmm, 4 core
15All as per item No 13here in before but of size 16 Sqmm, 2 core
16All as per item No 13here in before but of size 16 Sqmm, 4 core
17All as per item No 13here in before but of size 25 Sqmm, 3 1/2 core
18All as per item No 13here in before but of size 35 Sqmm, 3 1/2 core
19All as per item No 13here in before but of size 50 sqmm, 3 1/2 core
20All as per item No 13here in before but of size 70 sqmm, 3 1/2 core
21All as per item No 13here in before but of size 95 sqmm, 3 1/2 core
22All as per item No 13here in before but of size 120 sqmm, 3 1/2 core
23All as per item No 13here in before but of size 150 sqmm, 3 1/2 core
24All as per item No 13here in before but of size 185 sqmm, 3 1/2 core
25All as per item No 13here in before but of size 240 sqmm, 3 1/2 core
26Dismantling/uprootingof LT unserviceable pre-stressed concrete/steel poles of any size and length including taking out dismantled portion of poles embeded in concrete after necessary demolition ofconcrete foundation and disposal complete all as specefied and directed .
27M & L forPrestressed concrete pole, 9.0 metres long, 102 mm x 152 mm at top and 102mm x 289 mm at bottom,class 10 complete all as specefied and directed.
28Dismantling cross arms of MS channel or angle sections etc. and keeping serviceable materials in safe custody for re-use and/or unserviceable materials removing from the site complete all as specified and directed.
29Fixing only serviceable cross arm, MS Channel, angle section obtained from item No 28 above after painting with one coat of aluminium paint including preparation of old steel surfaces complete all as specified and directed.
30M&L Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections, including nuts, bots, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat (red oxide, zine chrome primer), one under coat and one finishing coat of aluminium paint including preparation of surfaces complete all as specified and directed.
31Dismantling of ACSR conductors or disturbed span including line spacer and keeping serviceable materials in safe custody for re-use and unserviceable materials removing from the site complete all as specified and directed.
32Fixing only by re-straining, tightening of ACSR conductors of any size/type on LT poles including necessary new aluminium binding wire for fixing with insulator/PVC sleeves for jumper etc as required complete all as specified and directed.(Note: Serviceable ACSR conductors shall be obtained from item No. 31 above).
33M&L for aluminium conductor steel reinforced (ACSR) on LT poles including straining, binding with insulators with aluminium binding wire with insulator as in OH conductor, providing PVC sleeves for jumpers complete all specified and directed.
34Dismantling insulators of any type and any size and keeping serviceable materials in safe custody for re-use and removing unserviceable materials from the site complete all as specified and directed.
35Fixing only serviceable pin type porcelain, vitreous, (white/brown or green) insulator for 1100 volts grade of any type obtained from item No 34 above.
36Fixing only serviceable shackle type porcelain, vitreous (white / brown or green) insulator of any size and shape for 1100 Volts grade obtained from item No 34 above.
37S&F pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100 mm height, 65 mm dia for 1100 volts grade complete all as specified and directed.
38S&F shackle type, porcelain, vitreous white, brown or green insulator including galvanised mild steel straps of size 31 x 3 mm, 12 mm dia insulator bolts, nuts and washers for working pressure 1100 volts of size 75 mm height, 90 mm dia complete all as specified and directed.
39Dismantling LT Stay assembly, of any size and unserviceable materials removing from the Site(s), complete all as specified and directed. a) Unserviceable Stay assembly shall be taken off/dismantled at Ground Level and making good disturbed ground surface. b)Rate is inclusive of necessary earthwork for demolition of cement concrete complete.
40M&L Stay assembly for LT complete with accessories as shown in Electrical plate No. 1 of MES schedule Part- I, 16 mm dia stay rod,7/3.15 mm galvanised stay strand complete all as specified and directed.(Note : Loop insulator, stay clamps, excavation/ earthwork and cement concrete shall be measured and paid for separately under relevant items of this Schedule).
41S&F loop type insulators vitreous porcelainwhite / brown or green small size with overall dimensions 65x90 mm clearance of hole 16 mm dia complete all as specified and directed.
42Dismantling earth wire of any size/dia, guarding cradle of disturbed span and keepingserviceable materialsin safe custody for re-use and removing unserviceable materials from the site complete all as specified and directed.
43Fixing only serviceable GI wire 3.15 mm or 4 mm dia martial obtained from item No 42 above complete all as specified and directed.
44M&L for cradles, hexagonal / rectangular, fabricated or continuous earth wire with galvanised steel wire 3.15 mm or 4 mm dia complete all as specified and directed.
45S&F PVC fibre separator for LT line 1100 volt OH conductor 3/4 wire system for maintaining horizontal spacing of conductor complete with nut & bolt minimum two nos in a span complete all as specified and directed.
46Trimming of tree branches around the LT /HT OH conductor, pole & stay (not less than 3 metre) to clear the over head lines including cleaning of birdnest, creepers on poles and stays etc complete as required including removing and disposed off from the site directed. Note : The quoted shall deemed to be inclusive of provision of periodically cleaning/cutting etc including disposal there-off and "span" will be measured & paid only once in entire contract period.
47M & L earthing complete with galvanised steel earth plate electrode 600 x 600 x 6mm thick, burried directly in ground (earth pit not less then 2.25m deep bellow ground level) with top edge of the plate not less then 1.5m deep below normal ground level connected to galvanised iron strip of 32 x 6mm earth lead by means of bolt, nuts, washers of galvanised steelearth strip protected by and including GI pipe 40mm dia bore (light grade) and conncted to main test point directed and including concrete pit in PCC(1:3:6)type C-1 precast RCC(1:1.5:3)type A-1 cover slab 54 x 5 cm reinforced with 4mm dia TMT bars @ 150 mm c/c both ways with one handle for lifting made out of 8mm dia TMT bar embedded in precast cover slab funnel wire mens 20mm bore GI pipe (medium grade) for watering charcoal and salt in altemate layers, including necessary excavation and earth work in any type of soil complete all as shown on electrical plate No3 of SSR part-I complete all as specified and directed.
48M&L Earthing complete with galvanised steel earth plate electrode 600X600X6 mm thick buried directly in groundpreferably vertically in ground with top edge not less than 1.25 mtr deep below normal ground level connected with and including galvanised iron wire 4 mm dia as earthing lead by means of nuts bolts and washers of galvanized iron protected by 15mm dia (medium grade) GI tubing, funnel, wire mesh, 20mm bore GI tubing (light grade) watering pipe , including concrete pit in PCC (1:3:6) type C-1, precast RCC (1:2:4) type B-1 cover slab of size 350x350x50mm reinforced with 8mm dia TMT bars @ 15cm c/c in both ways and 10mm dia MS handle (01 No) of suitable size, charcoal and salt in alternate layers necessary excavation and earth work in soft/loose soil all as shown in Electric plate No. 3 of SSR part-I and testing on completioncomplete all as specified and directed.
49Supply,install, commission and testing cubical type LT panel board ,outdoor canopytype, manufactured by a CPRI approved factory, floor mounted, dust & vermin proof,front and rear operated doorwithnecessary locking arrangement made of 50 x 6mm MS angle iron frame work and CRCA sheetof 3.00 mm thick duly painted with two coats of powder coated paint of approved shade after seven tank treatment process both internally and externally. The panel shall be suitable for 415 Volts, 50 HZ, 3 Phase 4 wire system and shall be complete with suitable capacity copper bus bar (1.5 times the incoming switch gear current rating) with suitable size of PVC insulated copper conductor, thimbles glands complete all as specified and directed with the following accessories :- INCOMING (a) MCCB 4 pole, 415 Volts,250 Amps, 25 KA - 01 No. OUTGOING (a) MCCB4 pole, 415 Volts, 125 Amps,16 KA -01 No.(b) MCCB4 pole, 415 Volts, 100 Amps,16 KA -02 Nos (c) MCCB4 pole, 415 Volts, 100 Amps,10 KA -01 Nos (Spare) (d) MCBTPN ,415 Volts, 32 Amps, -01 Nos (e) DigitalVAF meter for basic electric system monitoring-01 Nos. (f) Indicator lamp (RYB) (set of three) - 01 Set
50S&F TPN copper bus bar box, outdoor type of 200 A capacitymounted on porcelain bridge insulator for one incoming cable and 4 out going cable, housing in sheet metal enclosure of MS sheet 3.0 mm thick CRCA sheet and angle iron 40x40x6 mm frame, painted with two coatsincluding arrangement for cable gland for incoming and outgoing cables, locking arrangement, suitable foundation/platform for mounting the FPB with space for and including the following switch gears:(a) MCCB 100 A FP, 10 KA (for incoming control)
51M&L for Preparation of old painted surface above the planting depth and PCC coping of steel tubular LT pole of09.00 metre length including MS clamps ,cable protection pipe bracket fittedwith street light fittings etc by scraping with steel wire brush and applying two coats, of aluminium paint to external surface of poles MS cross arms MS clamp, cable protection pipe etc to give even shade including Zebra colour of painting from 1.5 mtr height from the top of coping/ bottom of pole as per site condition and numbering of poles complete all as specified and directed. Note:Zebra colour will be applied by synthetic enamel paint of black/yellow colour as approved in alternate layer of 30 cm height of each layer.
52M&L for Preparation of old painted surfaces and removing dust and other deposited material by scraping from LT PCC polesof09.00 metre length, cross arms brckets and applying 2 coats of aluminium paint to all steel surfaces, including MS clamps ,cable protection pipe bracket fittedwith street light fittings etcincluding Zebra colour of painting upto 1.5 mtr height from the top of coping/ bottom of pole as per site condition and numbering of poles complete all as specified and directed
53Supply, jointing and testing cable jointing kit for 1.1 KV grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 25-50 Sqmmcomplete all as specified and directed.
54Supply, jointing and testing cable jointing kit for 1.1 KV grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70-150 Sqmm complete all as specified and directed.
55Supply, jointing and testing cable jointing kit for 1.1 KV grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 25-50 Sqmm complete all as specified and directed.
56Supply, jointing and testing cable jointing kit for 1.1 KV grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70-150 Sqmm complete all as specified and directed.
57S&F voltmeter,digital type, 0-500 volt with in-built selector switch including taking down existing old/unserviceable voltmeter from LT panel /APFC Panelboard after carefully disconnecting the electric connection complete all as specified and directed
58S&F Ampere meter, digital type, 0-500 Amps with in-built selector switch, complete with suitable size of CT"s including taking down existing old/unserviceable Ammeter from LT panel /APFC Panel board after carefully disconnecting the electric connection complete all as specified and directed.
59S & F Indicator lamp, LED type of colour red, blue and yellowincluding taking down existing old/unserviceable lamps from LT panel /APFC Panelboard after carefully disconnecting the electric connection complete all as specified and directed .
60S&F MCCB,415 volts, 400 Amp, breaking capacity 36 KA, 4 pole including taking down existing old/unserviceable MCCB from LT panel /APFC Panelboard after carefully disconnecting the electric connection complete all as specified and directed
61S&F MCCB,415 volts, 250 Amp,breaking capacity 25 KA, 4 pole,including taking down existing old/unserviceable MCCB from LT panel /APFC Panelboard after carefully disconnecting the electric connection complete all as specified and directed
62S&F MCCB, 415 volts, 200 Amp,breaking capacity 25 KA, 4 pole,including taking down existing old/unserviceable MCCB from LT panel /APFC Panelboard after carefully disconnecting the electric connection complete all as specified and directed
63S&F MCCB, 415 volts, 160 Amp,breaking capacity 16 KA, 4 pole including taking down existing old/unserviceable MCCB from LT panel /APFC Panelboard after carefully disconnecting the electric connection complete all as specified and directed
64S&F MCCB, 125 Amp, 415 volts, breaking capacity 16 KA, 4 pole,including taking down existing old/unserviceable MCCB from LT panel /APFC Panel board after carefully disconnecting the electric connection complete all as specified and directed
65S&F MCCB, 100 Amp, 415 volts, breaking capacity 10 KA, 4 pole,including taking down existing old/unserviceable MCCB from LT panel /APFC Panelboard after carefully disconnecting the electric connection complete all as specified and directed
66S&F 3/4 pole Contactor for capacitor switching AC 230/240 Volt ,50 Hzs coil operated suitable for IEC rated 400 Volt,5-100 Amps max. complete all as specified and directed.
67S&F Contactor 3/4 pole ML -2.5 to 3.0 including taking down existing old/unserviceable contactor from LT panel /APFC Panelboard after carefully disconnecting the electric connection complete all as specified and directed.
68S&F Contactor 3/4 pole ML -4.0 including taking down existing old/unserviceable contactor from LT panel /APFC Panelboard after carefully disconnecting the electric connection complete all as specified and directed.
69Taking down the unserviceable capacitor from APFC panel and supply and fix cylindrical capacitorheavy duty of capacity 1 KVAR complete all as specified and directed.
70Taking down the unserviceable capacitor from APFC panel and supply and fix cylindrical capacitor heavy duty of capacity 3 KVAR complete all as specified and directed.
71Taking down the unserviceable capacitor from APFC panel and supply and fix cylindrical capacitor heavy duty of capacity 5 KVAR complete all as specified and directed.
72Taking down the unserviceable capacitor from APFC panel and supply and fix cylindrical capacitor heavy duty of capacity 7.5 KVAR complete all as specified and directed.
73Taking down the unserviceable capacitor from APFC paneland supply and fix cylindrical capacitor heavy duty of capacity 10 KVAR complete all as specified and directed.
74Taking down the unserviceable capacitor from APFC paneland supply and fix cylindrical capacitor heavy duty of capacity 15 KVAR complete all as specified and directed.
75Taking down the unserviceable capacitor from APFC paneland supply and fix cylindrical capacitor heavy duty of capacity 20 KVAR complete all as specified and directed.
76Taking down the unserviceable capacitor from APFC paneland supply and fix cylindrical capacitor heavy duty of capacity 25 KVAR complete all as specified and directed.
77Taking down the existing unserviceable automatic power factor control panel and supply and fix Automatic power factor control panel microprocessor based incuding LED display input voltage 415 V AC,+-15 %,50 Hzs,three phase delta connection with heavy duty cylindrical capacitor and 8 step controlof capacity 10 KVAr copmplete all as specified and directed. Make: Havells Cat Part No: QHKTCB5010X0 or equivalent in ABB, Siemens, L&T, Schneider, C&S
78Taking down the existing unserviceable CT from the LT panel/APFC panel and supply and fix LT CT ring type suitable for primary current ratio 100/5 Amps, burden 5 VA, class 1.0 complete all as specified and directed. Make: Havells Cat Part No:QSCELFBOL001 or equivalent in ABB, Siemens, L&T, Schneider, C&S
79Taking down the unserviceable dimmer from the servo voltage stabilizer of 75 KVA capacity and supply and fix in repairdimmer or variable transformer of servo voltage stabilizer of 75 KVA capacity complete all as specified and directed.
80Taking down the unserviceable carbon brush from the servo voltage stabilizer of 75 KVA capacity and supply and fix in repairnew carbon brush of servo voltage stabilizer of 75 KVA capacity complete all as specified and directed.
81Taking down the unserviceable buck boost transformer from the servo voltage stabilizer of 75 KVA capacity and supply and fix in repair new buck boost transformer of servo voltage stabilizer of 75 KVA capacity including necessary wiring complete all as specified and directed.
82Material and labour for servicing of servo voltage stabilizer of 75 KVA capacity including replacement of necessary wiring and copper lugs, contactors, relays etc. complete all as specified and directed. Note: Rate quoted must be inclusive of necessary wiring and copper lugs required to be replaced but the contactors and relays if required to be replaced will be measured and paid separately.