Military Engineer Services-MES has published Tender For Repair Replacement Of Ac Galvalium Sheets Shutters Roof Treatment And Chajja Etc And Repair Replacement Of Ug Cables Lt Switchgeares Joint Kits Cables And Other Connected Works Under Ge I Gos. Submission Date for this Tender is 20-02-2023. Switch Gear Tenders in gopalpur Odisha. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Dismantling of AC Corrugated / semi corrugated roof sheets any type and any size complete all as specified and directed. |
2 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed. |
3 | Dismantling structural steel work including doors, gates but excluding framed truss etc complete all as specified and directed. |
4 | S&F steel work in tubular poles & trusses (framed) including purlins,rafters and special shaped washer etc complete using ERW or induction butt welded tubes confirming to IS-1161-1979 grade St-240 complete all as specified and directed.. |
5 | Taking down existing water proofing membrance and cleaning roof, plastered surface etc preparing the surface to receive plaster by brushing with wire brush and fanning the surface to remove all loose dirt etc and brushing neat cement slurry @ 3.00 Kg/Sqm complete all as specified and directed. |
6 | M&L for rendering 15 mm thick surface as in roof with integral water proofing compound 3% by the weight of cement in cement mortar 1:4 complete all as specified & directed. (Integral WPC will be measured and paid separately). |
7 | M&L for water proofing treatment to roof surface complete all as specified & directed with the followings :- (a)Apply bituminous based primer confirming to IS: 3384-1965 @ 0.30 kg/sqm.(b)APP modified bituminous membrane 3mm thick with non woven polyester core of weight not less than 3.2 to 3.5 Kg/sqm laid and bonded to the sub strata by heat process, over laps of 100mm shall be sealed/fused by flame torch application as per manufacturer instructions. (c)Applying bituminous based aluminiumpaint @ 0.20 Kgs/Sqm in two coats over APP membrane |
8 | Supply only integral water proofing ISI marked compound all as specified and directed. |
9 | Taking down rolling shutters including all hardware fittings and removing to store complete all as specified & directed |
10 | M&L Cutting holes in brick walls/ stone walls exc one brick but not exc two brick built in cement mortor or cement lime mortor and stone walls built in lime mortor for inserting hold fasts and makinggood dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 type B-1 as requiredcomplete all as specified and directed. (Depth of embedded portion of holdfasts or lugs measured from the face of the jamb into the wall) |
11 | M&L for Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed. |
12 | S&F Guide channel 3" (3.50 mm thick mild steel deep channel section) complete all as specified and directed. |
13 | S&F 1 mm thick of steel rolling shutters without ball bearing as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer erected in position as indicated, gear operated type with bevel gear box and crank handle complete all as specified and directed. |
14 | S&F Ball bearing for rolling shutters complete all as specified and directed. |
15 | S&F Safety lever locks mild steel with 4 levers for rolling shutterscomplete all as specified and directed. |
16 | S&F Bottom plate 5" (2.25mm) for rolling shutterscomplete all as specified and directed. |
17 | Taking down cover hood of existing rolling shutters(gear operated/ manually size any type ) carefully and completely over hauling the shutters by applying grease and oil in bearing, springs, guide cannels, operating rods, shaft gear boxes, gear wheel etc straightening thoroughly shutter blades, guide channels anchoring rods etc and fixing back the over hood in position and ensure smooth functioning of shutters complete all as directed.(Note : worn out part for replacement will be measured and paid separately.) |
18 | Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed. |
19 | Supply and fixing in repairsonly MS gear box complete incl handle and anchoring rod as of approved quality of steel rolling shutters complete all as specified and directed. |
20 | All as per item no. 19 but Ball bearing suitable for rolling shutter |
21 | All as per item no. 19 but Guide channel 3" (3.50 mm thick) |
22 | All as per item no. 19 butHood Cover made of 1 mm thick GI Sheet pattern |
23 | All as per item no. 19 butBottom plate 5" (2.25mm) |
24 | All as per item no. 19 butC Class pipe 50 mm dia in shaft |
25 | All as per item no. 19 butAnchoring rod of 25 mm dia of MS pipe |
26 | All as per item no. 19 but Safety lever locks MS with 4 levers |
27 | All as per item no. 19 butMS Curtains of 1 mm thickRolling Shutter consisting of the assembly of lath sections end-locking clips and the connecting pieces at the top complete all as specified and directed. |
28 | M&L for two coats synthetic enamelled paint to new steel surfaces after preparation over a coat of red oxide primer area over exc 10cm in width or girth etc complete all as specified and directed. |
29 | M&L preparation of old decorated Steel painted surfaces of any description not other wise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed . |
30 | Taking down cement plaster on brick or concrete surface including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
31 | M&L for Rendering 15 mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces, finished even and smooth (without using extra cement) complete all as specified and directed. |
32 | M&L Preparation of newly Plastered surfaces and applying three coats of white wash complete all as specified and directed. |
33 | Painting to steel surfaces of any description n.exc. 10 cm in width or girth with two coats of synthetic enamel paint over a coat of Red oxide or Zinc chrome incl preparation of surfaces. |
34 | M&L for rendering 15 mm thick in CM (1:4) on fair faces of brick or concrete surface of wall and finished even and smoothwith out using extra cementand mixed with water proofing compound complete all as specified and directed. (Note: supply only of WPC shall be measured and paid for seperately ) |
35 | M & L for two coats of cement based paint onnewplastered surface of walls including preparation of surface complete all as specified and directed. |
36 | Excavation in trenches n .exc 1.5 mtr wide and not exec 1.5 mtr depth and getting out in looses/soft soil complete all as specified |
37 | Returing filling in incl spreading leveling, watering and well ramming in layer not less than 25 cum each layer all as specified. |
38 | Removing excavated material to a distance not exc 50M anddepositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified |
39 | Supply and laying double wall corrugated (DWC) HDPE pipe 50mm outer dia for protection of UG cable as per IS: 16205 (part 24) of 2017 complete all as specified. Make : Dutron |
40 | Supply and laying double wall corrugated (DWC) HDPE pipe 80 mm outer dia for protection of UG cable as per IS: 16205 (part 24) of 2017 complete all as specified |
41 | M&L PCC 1:4:8 type D 2 using 40 mm graded stone aggregate for fillingof pole & stay complete all as directed |
42 | M&L PCC 1:3:6 type C 2 using 40 mm graded stone aggregate for fillingof pole & stay complete all as directed |
43 | M&L PCC 1:2:4 type B1 using 20 mm graded stone aggregate for copining of pole complete all as directed |
44 | M & Lfortubelightgrade galvanisedwithallfittingslaidalong the pole/intrenches / underroadorfloorof50mmbore including removing the rusted old one completeallasspecifiedanddirected. |
45 | M & Lfortubelightgrade galvanisedwithallfittingslaidalong the pole/intrenches / underroadorfloorof80mmbore including removing the rusted old one completeallasspecifiedanddirected. |
46 | M & Lfortubelightgrade galvanisedwithallfittingslaidalong the pole/intrenches / underroadorfloorof100mmbore including removing the rusted old one completeallasspecifiedanddirected. |
47 | Taking out old unserviceable steel tubularpole 9 mtrs long and supply and fixing steel tubular swaged poles with cast iron base plate, finial taper plug, bolts, nuts, screws as specified type 410 SP-31 (9.0 mtr long) and erecting in position all as specified and directed with shifting of conductors and insulators including painting the exposed portion with two coats of aluminium paint over a coat of red oxide primer and internally through out plus embedded portion with two coats of black bituminous paint over a coat of red oxide primer with and including marking of pole number with black paint in yellow circle, complete, all as specified and directed. |
48 | Taking out old usserviceable PCC pole of any size and supply and fixing in repairs Prestressed concrete pole, 9.0 metres long, 102mm x 172mm at top and l02mm x 279mm at bottom, class 10 and erecting in position all as specified and directed with shifting of conductors and insulators including painting the exposed portion with two coats of weather proof paint , complete all as specified and directed. |
49 | M & L forRS Joist pole galvanized of size 150 mm x 75 mm of 09 meter long with MS base plate 6mm thick and of size 300 x 300 welded to bottom of pole, fixing of cross arms, black & yellow colour at lower portion of exposed pole starting from plinth blockband of 1200 mm height (4 Nos each Strip of 150 mm width), painting pole No by the black paint by stenciled letters/ figures of 8 cm height , complete all as specified and directed. Note:-Earthwork, Cement Concrete, cross arms etc. will be measured and paid under approprite Items. |
50 | M & L stay assembly complete with accessories as shown in electrical plate No 1 (Loop type insulator, stay clamps, excavation and concrete only measured separately) using diameter of stay rod 16 mm and MS stay plate 230mm x 230mm including taking down , complete all as specified and directed. |
51 | Taking out old10 Sqmm 2 Core UNSV and Supply, laying, jointing and testing ofXLPE insulated, armoured, heavy duty LT under ground cable 1100 Volts gradewith aluminium conductor laid in trenches, on poles, through pipes, fixed to walls etc cross sectional area for following sizes, including taking down old, , complete all as specified and directed. |
52 | All as per item no. 51 but of size 16 Sqmm 2 Core. |
53 | All as per item no. 51 but of size16 Sqmm 4 Core. |
54 | All as per item no. 51 but of size 25 Sqmm 3.5 Core. |
55 | All as per item no. 51 but of size35 Sqmm 3.5 Core |
56 | All as per item no. 51 but of size50 Sqmm 3.5 Core |
57 | All as per item no. 51 but of size70 Sqmm 3.5 Core |
58 | All as per item no. 51 but of size 95 Sqmm 3.5 Core |
59 | M/L for replacement of Earthing complete with GI earthplate 60x60cmx6mm thick electrode and using galvanised iron strip 32 x 6 mm as earthing lead burried directly in ground ( earth pit not less then 2.25 metres deep below ground level ) with top edge of the plate not less then 1.5 metres below normal ground level. connected to GI wire earth lead 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR Part-I and incl earth work,PCC pit and RCC cover,watering pipe 20 mm dia light grade,funnel,wire mesh,protection pipe 15 mm dia light grade up to 7.5 mtr length of earth wire,charcoal dust and salt etc and connected to earthing test point , complete all as specified and directed. |
60 | Supply and fixing of moulded case circuit breaker Four pole 100/125 Amps 18 KA capacity 415V 50Hz with adjustable thermal and magnetic release adjustable overlaod 100-80%, adjustable short circuit 5-10 Inincl taking out the old unserviceable , complete all as specified and directed. (Make of MCCB"s)L&T/Siemens/Legrand). |
61 | Supply and fixing of moulded case circuit breaker Four pole 160 Amps 25 KA capacity 415V 50Hz with adjustable thermal and magnetic release adjustable overlaod 100-80%, adjustable short circuit 5-10 Inincl taking out the old unserviceable, complete all as specified and directed.Make of MCCB"s) L&T/Siemens/Legrand). |
62 | Supply and fixing of moulded case circuit breaker Four pole 200 Amps 25 KA capacity 415V 50Hz with adjustable thermal and magnetic release adjustable overlaod 100-80%, adjustable short circuit 5-10 Inincl taking out the old unserviceable , complete all as specified and directed. (Make of MCCB"s)L&T/Siemens/Legrand). |
63 | Supply and fixing of moulded case circuit breaker Four pole 250 Amps 36 KA capacity 415V 50Hz with adjustable thermal and magnetic release adjustable overlaod 100-80%, adjustable short circuit 5-10 Inincl taking out the old unserviceable , complete all as specified and directed. (Make of MCCB"s) L&T/Siemens/Legrand). |
64 | Supply and fixing of moulded case circuit breaker Four pole 320 Amps 50 KA capacity 415V 50Hz with adjustable thermal and magnetic release adjustable overlaod 100-80%, adjustable short circuit 5-10 Inincl taking out the old unserviceable, complete all as specified and directed. (Make of MCCB"s) L&T/Siemens/Legrand). |
65 | Supply and fixing of moulded case circuit breaker Four pole 400 Amps 50 KA capacity 415V 50Hz with adjustable thermal and magnetic release adjustable overlaod 100-80%, adjustable short circuit 5-10 Inincl taking out the old unserviceable, complete all as specified and directed. (Make of MCCB"s) L&T/Siemens/Legrand). |
66 | Supply and fixing of digital voltmeter 0 to 500 volts 96 x96mm flush type in LT Panels incl taking out the old unserviceable complete allasspecifiedanddirected. |
67 | Supply and fixing of digital ammeter range as per existing 96 x96mm flush type in LT panels incl taking out the old unserviceable complete allasspecifiedanddirected. |
68 | Supply and fixing of LT current transformer ratio from 200/5 Ampsor 100/5 or 400/5 in LT panels incl taking out the old unserviceable complete allasspecifiedanddirected. |
69 | Supply and fixingselector switch of voltmeter/ammeter in LT panel boards incl taking out the old unserviceable complete allasspecifiedanddirected. |
70 | Supply and fixing indicator assembly (RYB) LED type in LT panel boards incl taking out the old unserviceable complete allasspecifiedanddirected. |
71 | M&L for painting steel tubular/RS joist pole 9 mtrs long alongwith bends with two coats of aluminium paint over a coat of red oxide primer and internally through out plus embedded portion with two coats of black bituminous paint over a coat of red oxide primer with and including marking of pole number with black paint in yellow circle, complete, all as specified and directed. |
72 | M&L for painting to LT panels of any size with two coats of sky blue paint over a coat of red oxide primer outerside and two coats of off white paint over a coat of red oxide primer internally complete all as specified and directed by Engr- in-Charge. Note: 1. Before painting the contractor will ask for a shut down of the recpective feeder from the JE.2. While painting of the panels protection of MCCB"s and MCB"s to be taken care of by the contractor.Any damage occured during the painting will be bear by the contractor, complete all as specified and directed. |
73 | S&F of Cable jointing kit for 1.1 KV (Earthed)grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 4 core XLPE armoured aluminium conductor cable of size 25-50 sqmm , complete all as specified and directed. |
74 | S&F of Cable jointing kit for 1.1 KV (Earthed)grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 4 core XLPE armoured aluminium conductor cable of size 70 to 120 sqmm , complete all as specified and directed. |
75 | S&F of Cable jointing kit for 1.1 KV (Earthed)grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 4 core XLPE armoured aluminium conductor cable of size 150 to 185 sqmm , complete all as specified and directed. |
76 | Boring of holes horizontally for laying of 80mmdia pipe (minimum depth 0.60 Mtr from top level) under road, Pavement, hard standing complete all as specified and directed. |
77 | Supply and fixing Aluminium tube terminal/ lugs of 10 to 25 Sqmm size , complete all as specified and directed. |
78 | All as per item no. 77but of size 35 to 50 Sqmm |
79 | All as per item no. 77but of size 70 to 120 Sqmm |
80 | All as per item no. 77but of size 150 to 185 Sqmm |
81 | All as per item no. 77but of size 240 to 300 Sqmm |
82 | Supply only PVC Electricalinsulation self adhesive tape 1.8cmx7mx0.125mmfor Red, Yellow, Blue & Green , complete all as specified and directed. |
83 | Supply, fabricate, erect, test and commission in replacement outdoor LT MS Feeder pillar box totally enclosed weather and vermin proof, suitable verntilated, 440 Volts, 50 HZ, AC Supply, factory made standard design as per electrical requirements to suit power distr sys , enclosure fabricated out of 3.00 mm thick MS sheet, excavation and earth work, PCC foundation etc,with hinged doors and lcoking arrangemetn , air vents, tappered roof, incoming and outgoing cable connections from bottom with compressed cable gland etcas required with and including the following, supplied fitted and connected internally complete04 Nos aluminiumbus bar of size 50 x 10 mm with PVC coloured heat srinkable type sleeves continous phase rating 400 Amps rating mounted on non cracting resin type insulators , complete all as specified and directed. |
84 | S&F in repair/ repalcement of on load change over switches 4 pole 160A in open execution, 415 volts, 50 Hz complete all as specified and directed. |
85 | S&F in repair/ repalcement of on load change over switches 4 pole 200A in open execution, 415 volts, 50 Hz complete all as specified and directed. |
86 | S&F in repair/ repalcement of on load change over switches 4 pole 250Aamp in open execution, 415 volts, 50 Hz complete all as specified and directed. |
87 | S&F in repair/ repalcement of on load change over switches 4 pole 400Amp in open execution, 415 volts, 50 Hz complete all as specified and directed. |
88 | S&F in repairs Aluminium strip 32x6 mmwith saddles and fixing screws etc. for roofconductors and down conductors above ground, complete all as specified and directed. |
89 | S&F in repairs Air termination, single pointed aluminium rod 12mm dia and 300mm long complete all as specifed and directed. |
90 | M&L for in repairs Aluminium conductor, steel reinforced, to stringe against the old unsv overhead conductor of suitable size with keep proper sag as applicable complete all as specified and directed. |
91 | M&L for repairing to the exisitng MS LT panel by welding hinges, fixinging nuts and bolts of suitable size for the inner compartments/ outer door complete all as specified and directed. |
92 | M & L for earth continuity conductor using GI strip 32 x 6 mm galvanised iron strip complete all as directed incl taking down the old unserviceable , complete all as specified and directed. |
93 | Taking up or down XLPE cable with connections for detecting the fault and after repair relaying the same complete, all as specified and directed. Note :- Measurement for excavation, returning, removing, sand and brick will be measured and paid at appropriate items of this sechdule. |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy