Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #35986718

Tender For Repair And Servicing Of Fan Coil Units (Fcu) ,Boilers, Pipelines And Allied Items In The Aor Of Ge 864 Ews

Issued by Statutory Bodies & Commissions/Committees · Srinagar, Jammu And Kashmir
Tender Value
12 Lakhs
Estimated cost
Bid Submission
13 Mar 2023
0 days left
EMD
24000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Srinagar → Jammu And Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Repair And Servicing Of Fan Coil Units ( Fcu ) , Boilers, Pipelines And Allied Items In The Aor Of Ge 864 Ews -M&L For Dismantling Of Centralized Hot Water Generators For Servicing Of Capacity 70000 - 100000 Kcl / Hr By Disconnection Of All Water And Electrical Connectionsisolatingburner Unit Assemblyfrom Main Boiler Unit Forrepair Workand Reassembling, Testing Of The Same Complete All As Specified And Directed By Engr-In Charge.Note:- Spares Shall Be Measured And Paid Under Respective Item ) 2 S & F In Replacement Nozzle Of Size2.5 -4.5 Gph At 70 Degree Suitable For Burner Upto Capacity 100000 Kcal / Hr 3 S & F In Replacement Sequence Controller Suitable For Burner Of Capacity 70000 To 100000 Kcal / Hr. 4 S & F In Replacement Fuel Filter Element Suitable For Burner Of Capacity 70000 To 100000 Kcal / Hr As Per Sample. 5 S & F In Replacement Thermostat Switch Suitable For Burner Of Capacity 70000 To 100000 Kcal / Hr. 6 S & F In Replacementfuel Feed Pump Suitable For Burner Of Capacity 70000 To 100000 Kcal / Hr 7 S & F In Replacement Heavy Duty Wiremesh Bounded Fuel Pipe With Flare Nutboth Ends As Per Sample 8 S & F In Replacement High Temperature Ignition Cable Suitable For Burner Of Capacity 70000 To 100000 Kcal / Hr 9 S & F In Replacement Led Display Unit ( Subzero ) With Control Wiring 10 S & F In Replacement Main Combustion Chamber Including Coils Of Capacity 10000 To 200000 Kcl / Hr.Make 11 Supply And Fixing In Replacementsealed Reciprocating Compressor Unit For 2 Trcomplete, All As Specified And As Directed. 12 Supply And Fixing In Replacementsealed Reciprocating Compressor Unit For 1.5 Trcomplete, All As Specified And As Directed. 13 M&L For Servicing Ofac Plant Installed At Various Installation Cleaning Of Condensing Unit Checking Of All Wiring If Found Damaged Repalce The Damage All Wiring Any Type As Per Existing Complete All As Directed By Engr-In-Charge. 14 S&F In Repacement Of Digital Control Panel / Remote Control Of Package Type Ac Plant Instaalled At Sand Model Room As Per Site Requirement Or As Per Sample Complete As Directed By Engr-In-Chagre. 15 Supply And Filling Of Refrigerant Of R 410-A In Cooling Plant Installed At Installation. 16 Supply And Filling Of Refrigerant Of R 22 In Cooling Plant Installed At Installation.Note : ( Refrigerant Should Be In The Packing Of 450 Gm Tin ) 17 Supply And Fixing In Replacement Replacement Of Compressor A Type Suitable For Refrigerators Of Capacity 165-180 Ltrs. 18 Supply And Fixing In Replacement Replacement Of Compressor B Type Suitable For Refrigerators Of Capacity 190-240Ltrs . 19 Supply And Fixing In Replacement Replacement Of Compressor C Type Suitable For Refrigerators Of Capacity 240-410Ltrs . 20 Supply And Fixing In Replacement Replacement Of Compressor 411 Kcn / 415 Kcn Suitable Fordeep Freezer Of Capacity 260-600 Ltrs . 21 Supply And Fixingin Replacement Printed Circuit Board For Split Type Non Inverter / Inverter Acoperatingathot & Cold Mode Of Capacity 1.5 / 2T. 22 Supply And Fixing In Replacement Starting Capacitors 36-200Mfd 6 Pin / 4 Pin Complete All As Specified And As Directed 23 Supply And Filling Of Refrigerant R-134 ( A ) / Hydro Carbon Blend / R-600 ( A ) Including Nitrogen Flushing , Vaccumizationand Pressure Testing Complete All As Directed. 24 Supply Only Teflon Tape 15 Mm X 15 Mtr 25 Supply Only Pvc Insulation Tape15 Mm X 5 Mtr 26 Supply Only Aaa Size Battery 1.5 Volt. 27 Supply & Fix Indoor Unit Blower Motor With Blower 1.5 Tr / 2 Tr Airconditioner Any Type & Any Make As Per Sampleincluding Inverter Model 28 Supply & Fix Outdoor Unit Fan Motor With Fan1.5 Tr / 2 Trairconditioner Any Type & Any Make As Per Sampleincluding Inverter Model 29 Supply Only Pvc Frls Unsheathedcopperer Conductor Single Core6 Sqmm. 30 Supply Only Remote Control For 1.5 / 2.0 Tr Inverter / Nonnverter Airconditioner Of Any Type & Make As Per Sample 31 M&L Dismantling The Steam Boiler Coil & Descaling Of Steam Boiler 600Kg / Hr By Opening Of Boiler Coilcover From Theboth Sides Including Disconnecting Ofinlet And Outlet Water Connectionsof Theboiler. Closing Both Side Of Coil And Circulating The Descaling Compound Solutionin Tubes Of Boiler Through The Separate Circulatingpump And Allow The Descaling Solution To Hold For 1Hr For Chemical Reaction. After The Duration Of 1 Hr Open The Coil Ends And Ensuringthat The Coil Has Been Descaled Upto Max Clean Range , Then Closingboth Theends Of The Coil And Circulating Clean Water Inthe Tubes Of Boiler And Draining It Out, The Process Will Be Continued Till The Satisfaction Of Engr-In-Charge Then Refixing The Coil Inside The Chamber Complete With All Fixing Material Required At Site: 32 Supply & Fixing In Replacement Of Photo Cell Complete With Holder. Model-8205. 33 Supply & Fixing In Replacement Of Ignition Transformer ( 14500V ) . 34 Supply & Fixing In Replacement Of Pressure Gauge 4 Dia Connection Centre Back Mount, Dial Range - 20 Kg To 25 Kgas Per Sample Complete All As Directed By Engr-In-Charge. 35 Supply & Fixing In Replacement Of Temperature Gauge Dia 2Connection Centre Back Temperature Roadas Per Sample Complete All As Directed By Engr-In-Charge. 36 S&F In Repacement Of Electric Hooter For Boiler 600 Kg / Hrsas Per Sample Complete All As Directed By Engr-In-Charge. 37 Supply & Fixing In Replacement Of Heavy Duty Steam Pressure Gate / Ball Valve 15 To 25 Mm Diaas Per Sample Complete All As Directed By Engr-In-Charge. 38 Supply & Fixing In Replacement Of Heavy Duty Nrv Valve 15 To 25 Mm Dia, As Per Sample Complete All As Directed By Engr-In-Charge. 39 Supply & Fixing In Replacement Of Copper Tube Dia 8 Mm / 12 Mmas Per Sample Complete All As Directed By Engr-In-Charge. 40 Supply & Fixing In Replacement Of Heavy Duty Inlet / Outlet Hose Pipe With Wire Mesh Of Any Size And Any Lengthas Per Sample Complete All As Directed By Engr-In-Charge. 41 M&L For Rewinding Of Burnt Motor From Respective Laundry Machinesby Disconnecting All Electrical And Mechanical Connections And Reassembling, Testing Of The Same After Carrying Out Rewinding Of Motorofunder Mentioned Capacity Single / Three 3Ph 415Volt, 50Hz With Supper Enamelled Copper Wire Having Same Gauge After Taking Out Old Burnt Winding Including Replacement Of Bearing Complete And All As Specified:--1Hp To 2 Hp 42 M&L For Rewinding Of Burnt Motor From Respective Laundry Machinesby Disconnecting All Electrical And Mechanical Connections And Reassembling, Testing Of The Same After Carrying Out Rewinding Of Motorofunder Mentioned Capacity Single / Three 3Ph 415Volt, 50Hz With Supper Enamelled Copper Wire Having Same Gauge After Taking Out Old Burnt Winding Including Replacement Of Bearing Complete And All As Specified:--3Hp To 5 Hp 43 M&L For Rewinding Of Burnt Motor From Respective Laundry Machinesby Disconnecting All Electrical And Mechanical Connections And Reassembling, Testing Of The Same After Carrying Out Rewinding Of Motorofunder Mentioned Capacity Single / Three 3Ph 415Volt, 50Hz With Supper Enamelled Copper Wire Having Same Gauge After Taking Out Old Burnt Winding Including Replacement Of Bearing Complete And All As Specified:--7.5 Hp To 10 Hp 44 M&L For Rewinding Of Burnt Motor From Respective Laundry Machinesby Disconnecting All Electrical And Mechanical Connections And Reassembling, Testing Of The Same After Carrying Out Rewinding Of Motorofunder Mentioned Capacity Single / Three 3Ph 415Volt, 50Hz With Supper Enamelled Copper Wire Having Same Gauge After Taking Out Old Burnt Winding Including Replacement Of Bearing Complete And All As Specified:--12.5 Hp To 20 Hp 45 Supply & Fixing In Replacement Of V Belt Forwasher Extractor Of Capacity - 60 Kg, As Per Sample Complete All As Directed By Engr-In-Charge. 46 Supply & Fixing In Replacement Of Main Drain Valve ( Actuator Butterfly Valve ) Forwasher Extractor Of Capacity - 60 Kg, As Per Sample Complete All As Directed By Engr-In-Charge. 47 Supply & Fixing In Replacement Of Main Water Inlet Valve ( Actuator Butterfly Valve ) Forwasher Extractor Of Capacity - 60 Kg As Per Sample Complete All As Directed By Engr-In-Charge. 48 Supply & Fixing In Replacement Of Single Solenoid Valve Forwasher Extractor Of Capacity - 60 Kg, As Per Sample Complete All As Directed By Engr-In-Charge. 49 Supply & Fixing In Replacementof Display Controller Forwasher Extractor Of Capacity - 60 Kg, As Per Sample Complete All As Directed By Engr-In-Charge. 50 Supply & Fixing In Replacement Of Door Gasket Forwasher Extractor Of Capacity - 60 Kg, As Per Sample Complete All As Directed By Engr-In-Charge. 51 Supply & Fixing In Replacement Of Hose Pipe Of Dia 4 Forwasher Extractor Of Capacity - 60 Kg, As Per Sample Complete All As Directed By Engr-In-Charge. 52 Supply & Fixing In Replacementof V Belt For Washer Extactor Of Capacity - 30 Kg, As Per Sample Complete All As Directed By Engr-In-Charge. 53 Supply & Fixing In Replacementof Silicon Oil Seal With Circlip & O Ring For Slucing Machine Of Capacity - 30 Kg, As Per Sample Complete All As Directed By Engr-In-Charge. 54 Supply & Fixing In Replacement Of Main Drive V Belts For Drying Tumbler As Per Sample Complete All As Directed By Engr-In-Charge. 55 Supply & Fixing In Replacement Of Automatic Steam Inlet Valve For Drying Tumbler As Per Sample Complete All As Directed By Engr-In-Charge. 56 Supply & Fixing In Replacement Of Contactor For Drying Tumbleras Per Sample Complete All As Directed By Engr-In-Charge. 57 Supply & Fixing In Replacement Of Solenoid Valve For Vaccum Ironing Machine As Per Sample 58 Supplying, Mixing And Filling Of Mono Ethylene Glycol Concentrate Along With The Necessary Additives And Inhibitor In Cognition, Required For Operation Of Plant And Network. The Mixing Freezing Temperature Shall Be Minus 10 Degree C All As Sprecified And Directed By Engr-In-Charge. 59 Supply And Mixing Hydro Caloric Acid ( Hcl ) Concentrate. 60 Supply And Fixing In Replacement Under Mentioned Items For Oil Fired Incinerator Model Py-Vs-75As Per Sample Complete All As Directed By Engr-In-Charge.:- Photo Cell 61 Fuel Filter Element Per Sample Complete All As Directed By Engr-In-Charge. 62 Thermo Couple K Type Per Sample Complete All As Directed By Engr-In-Charge. 63 Pressure Gauge 0-40 Kgs / Cm 2-1 / 4 Bsp Per Sample Complete All As Directed By Engr-In-Charge. 64 Electrode Front Pair Per Sample Complete All As Directed By Engr-In-Charge. 65 S&F In Replacement Of Solenoid Valve Of Incinerator As Per Sample Complete All As Directed By Engr-In-Charge. 66 Electrode Rear Pair As Per Sample Complete All As Directed By Engr-In-Charge. 67 Sequence Controller As Per Sample Complete All As Directed By Engr-In-Charge. 68 Oil Seal For Fuel Pump As Per Sample Complete All As Directed By Engr-In-Charge. 69 Ht Cable As Per Sample Complete All As Directed By Engr-In-Charge. 70 Spider Lo-70 ( Rubber Bush ) As Per Sample Complete All As Directed By Engr-In-Charge. 71 S&F In Replacement Of Main Steam Inlet Valve Automaticfor Washer Extractor 60 Kg Aper Sample Complete All As Directed By Engr-In-Charge. 72 S&F In Replacement Of Thermocouple For Washer Extractor 60 Kgas Per Sample Complete All As Directed By Engr-In-Charge. 73 Supply And Mixing Industrial Salt In Water For Descalingfor Steam Boiler 600 Kg / Hr 74 Supply And Fixing Fuel Feed Pump Suitable For 3 Three Phase Burner Assembly Of Capacity 100000 K Cal To 400000 As Per Sample Complete All As Directed By Engr-In-Charge. 75 S&F In Replacement Of Touch Screen Hmi For Washer Extractor 60 / 30 Kg Or As Per Site Reqirement As Per Sample. 76 Supply And Mixing Descaling Compound For Steam Boiler 600 Kg / Hr Per Sample Complete All As Directed By Engr-In-Charge. 77 M&L For Dismentaling / Opening Of Old Damage Heary Duty Ms Pipe Fittings From Bilers Of Any Shape / Size And Replacement With New As Heavy Duty Ms Pipe Fitting As Per Site Requirement Including Necessary Threading, Welding Work, Flange, Gasket Of Any Size With Nut Bolts Complete All As Directed By Engr-In-Charge 78 S & Ftriplex Spray Pump For Boiler Of Cap 24 Ltrs / Hr. 79 S & F Gland Washer Htn008n For Boiler 80 S & F Valve Assembly Htb / Va For Boiler 81 S & Fpvc Washer For Valve Gauge Htb / 002

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 17-Feb-2023 POSTPONED Date 06-Mar-2023
2 06-Mar-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 13-Mar-2023

BOQ

Name of Work:REPAIR AND SERVICING OF FAN COIL UNITS (FCU) , BOILERS, PIPELINES AND ALLIED ITEMS IN THE AOR OFGE 864 EWS
Sl. No. Item Description
1M&L for dismantling of Centralized hot water generators for servicing of capacity 70000 - 100000 Kcl/Hr by disconnection of all water and electrical connectionsisolatingburner unit assemblyfrom main boiler unit forrepair workand reassembling, testing of the same complete all as specified and directed by Engr-in Charge.Note:- Spares shall be measured and paid under respective item)
2S & F in replacement Nozzle of size2.5 -4.5 GPH at 70 degree suitable for burner upto capacity 100000 Kcal/hr
3S & F in replacement Sequence controller suitable for burner of capacity 70000 to 100000 Kcal/hr.
4S & F in replacement Fuel filter element suitable for burner of capacity 70000 to 100000 Kcal/hr as per sample.
5S & F in replacement Thermostat switch suitable for burner of capacity 70000 to 100000 Kcal/hr.
6S & F in replacementFuel feed pump suitable for burner of capacity 70000 to 100000 Kcal/hr
7S & F in replacement Heavy duty wiremesh bounded fuel pipe with flare nutboth ends as per sample
8S & F in replacement High temperature ignition cable suitable for burner of capacity 70000 to 100000 Kcal/hr
9S & F in replacement LED Display unit (subzero)with control wiring
10S & F in replacement main combustion chamber including coils of capacity 10000 to 200000 KCl/Hr.Make
11Supply and fixing in replacementsealed reciprocating compressor unit for 2 TRcomplete, all as specified and as directed.
12Supply and fixing in replacementsealed reciprocating compressor unit for 1.5 TRcomplete, all as specified and as directed.
13M&L for servicing ofAC plant installed at various installation cleaning of condensing unit checking of all wiring if found damaged repalce the damage all wiring any type as per existing complete all as directed by Engr-in-charge.
14S&F in repacement of digital control panel/remote control of package type AC plant instaalled at sand model room as per site requirement or as per sample complete as directed by Engr-in-Chagre.
15Supply and filling of refrigerant of R 410-A in cooling plant installed at installation.
16Supply and filling of refrigerant of R 22 in cooling plant installed at installation.Note :(Refrigerant should be in the packing of 450 gm tin)
17Supply and fixing in replacement replacement of compressor A type suitable for refrigerators of capacity 165-180 Ltrs.
18Supply and fixing in replacement replacement of compressor B type suitable for refrigerators of capacity 190-240Ltrs .
19Supply and fixing in replacement replacement of compressor C type suitable for refrigerators of capacity 240-410Ltrs .
20Supply and fixing in replacement replacement of compressor 411 KCN /415 KCN suitable fordeep freezer of capacity 260-600 Ltrs .
21Supply and fixingin replacement Printed Circuit Board for split type non inverter/ inverter ACoperatingathot & cold mode of capacity 1.5 /2T.
22Supply and fixing in replacement starting capacitors 36-200MFD 6 pin / 4 pin complete all as specified and as directed
23Supply and filling of refrigerant R-134(a) / hydro carbon blend/ R-600 (a)including nitrogen flushing , vaccumizationand pressure testing complete all as directed.
24Supply Only Teflon tape 15 mm X 15 mtr
25Supply Only PVC insulation tape15 mm X 5 mtr
26Supply Only AAA size battery 1.5 volt.
27Supply & Fix indoor unit blower motor with blower 1.5 Tr/2 tr airconditioner any type & any make as per sampleincluding inverter model
28Supply & Fix outdoor unit fan motor with fan1.5 Tr/2 trairconditioner any type & any make as per sampleincluding inverter model
29Supply Only PVC FRLS unsheathedcopperer conductor single core6 sqmm.
30Supply Only remote control for 1.5 /2.0 tr inverter/ Nonnverter airconditioner of any type & make as per sample
31M&L dismantling the steam boiler coil & descaling of Steam Boiler 600Kg/Hr by opening of boiler coilcover from theboth sides including disconnecting ofinlet and outlet water connectionsof theboiler. Closing both side of coil and circulating the descaling compound solutionin tubes of boiler through the separate circulatingpump and allow the descaling solution to hold for 1hr for chemical reaction. After the duration of 1 hr open the coil ends and ensuringthat the coil has been descaled upto max clean range , then closingboth theends of the coil and circulating clean water inthe tubes of boiler and draining it out, the process will be continued till the satisfaction of Engr-in-Charge then refixing the coil inside the chamber complete with all fixing material required at site:
32Supply & fixing in replacement of photo cell complete with holder. Model-8205.
33Supply & fixing in replacement of ignition transformer (14500V).
34Supply & fixing in replacement of Pressure gauge 4\"\" dia Connection centre back mount, dial range - 20 kg to 25 kgas per sample complete all as directed by Engr-in-Charge.
35Supply & fixing in replacement of temperature gauge dia 2\"\"Connection centre back temperature roadas per sample complete all as directed by Engr-in-Charge.
36S&F in repacement of electric hooter for boiler 600 Kg/hrsas per sample complete all as directed by Engr-in-Charge.
37Supply & fixing in replacement of heavy duty steam pressure gate/ball Valve 15 to 25 mm diaas per sample complete all as directed by Engr-in-Charge.
38Supply & fixing in replacement of heavy duty NRV valve 15 to 25 mm dia,as per sample complete all as directed by Engr-in-Charge.
39Supply & fixing in replacement of copper tube dia 8 mm/12 mmas per sample complete all as directed by Engr-in-Charge.
40Supply & fixing in replacement of heavy duty inlet/outlet hose pipe with wire mesh of any size and any lengthas per sample complete all as directed by Engr-in-Charge.
41M&L for rewinding of burnt motor from respective laundry machinesby disconnecting all electrical and mechanical connections and reassembling, testing of the same after carrying out rewinding of motorofunder mentioned capacity single/three 3ph 415Volt, 50Hz with supper enamelled copper wire having same gauge after taking out old burnt winding including replacement of bearing complete and all as specified:--1HP to 2 HP
42M&L for rewinding of burnt motor from respective laundry machinesby disconnecting all electrical and mechanical connections and reassembling, testing of the same after carrying out rewinding of motorofunder mentioned capacity single/three 3ph 415Volt, 50Hz with supper enamelled copper wire having same gauge after taking out old burnt winding including replacement of bearing complete and all as specified:--3HP to 5 HP
43M&L for rewinding of burnt motor from respective laundry machinesby disconnecting all electrical and mechanical connections and reassembling, testing of the same after carrying out rewinding of motorofunder mentioned capacity single/three 3ph 415Volt, 50Hz with supper enamelled copper wire having same gauge after taking out old burnt winding including replacement of bearing complete and all as specified:--7.5 HP to 10 HP
44M&L for rewinding of burnt motor from respective laundry machinesby disconnecting all electrical and mechanical connections and reassembling, testing of the same after carrying out rewinding of motorofunder mentioned capacity single/three 3ph 415Volt, 50Hz with supper enamelled copper wire having same gauge after taking out old burnt winding including replacement of bearing complete and all as specified:--12.5 HP to 20 HP
45Supply & fixing in replacement of V Belt forWasher Extractor of capacity - 60 Kg, as per sample complete all as directed by Engr-in-Charge.
46Supply & fixing in replacement of Main drain valve (actuator butterfly valve) forWasher Extractor of capacity - 60 Kg, as per sample complete all as directed by Engr-in-Charge.
47Supply & fixing in replacement of Main water inlet valve (actuator butterfly valve) forWasher Extractor of capacity - 60 Kg as per sample complete all as directed by Engr-in-Charge.
48Supply & fixing in replacement of single solenoid valve forWasher Extractor of capacity - 60 Kg, as per sample complete all as directed by Engr-in-Charge.
49Supply & fixing in replacementof display controller forWasher Extractor of capacity - 60 Kg, as per sample complete all as directed by Engr-in-Charge.
50Supply & fixing in replacement of Door gasket forWasher Extractor of capacity - 60 Kg, as per sample complete all as directed by Engr-in-Charge.
51Supply & fixing in replacement of Hose pipe of dia 4\" forWasher Extractor of capacity - 60 Kg, as per sample complete all as directed by Engr-in-Charge.
52Supply & fixing in replacementof V Belt for washer extactor of capacity - 30 Kg, as per sample complete all as directed by Engr-in-Charge.
53Supply & fixing in replacementof silicon oil seal with circlip & O ring for Slucing machine of capacity - 30 Kg, as per sample complete all as directed by Engr-in-Charge.
54Supply & fixing in replacement of Main drive V belts for Drying tumbler as per sample complete all as directed by Engr-in-Charge.
55Supply & fixing in replacement of Automatic steam inlet valve for Drying tumbler as per sample complete all as directed by Engr-in-Charge.
56Supply & fixing in replacement of Contactor for Drying tumbleras per sample complete all as directed by Engr-in-Charge.
57Supply & fixing in replacement of solenoid Valve for Vaccum ironing machine as per sample
58Supplying, mixing and filling of mono ethylene glycol concentrate along with the necessary additives and inhibitor in cognition, required for operation of plant and network. The mixing freezing temperature shall be minus 10 degree C all as sprecified and directed by Engr-in-Charge.
59Supply and mixing Hydro caloric acid (HCL) concentrate.
60Supply and fixing in replacement under mentioned items for oil fired incinerator model PY-VS-75as per sample complete all as directed by Engr-in-Charge.:- Photo cell
61Fuel filter element per sample complete all as directed by Engr-in-Charge.
62Thermo couple K type per sample complete all as directed by Engr-in-Charge.
63Pressure gauge 0-40 Kgs/Cm 2-1/4\" BSP per sample complete all as directed by Engr-in-Charge.
64Electrode front pair per sample complete all as directed by Engr-in-Charge.
65S&F in replacement of solenoid valve of incinerator as per sample complete all as directed by Engr-in-Charge.
66Electrode rear pair as per sample complete all as directed by Engr-in-Charge.
67Sequence controller as per sample complete all as directed by Engr-in-Charge.
68Oil seal for fuel pump as per sample complete all as directed by Engr-in-Charge.
69HT cable as per sample complete all as directed by Engr-in-Charge.
70Spider LO-70 (Rubber Bush)as per sample complete all as directed by Engr-in-Charge.
71S&F in replacement of main steam inlet valve automaticfor washer extractor 60 Kg aper sample complete all as directed by Engr-in-Charge.
72S&F in replacement of thermocouple for washer extractor 60 Kgas per sample complete all as directed by Engr-in-Charge.
73Supply and mixing industrial salt in water for descalingfor steam boiler 600 Kg/hr
74Supply and fixing fuel feed pump suitable for 3 three phase burner assembly of capacity 100000 K cal to 400000 as per sample complete all as directed by Engr-in-Charge.
75S&F in replacement of touch screen HMI for washer extractor 60/30 Kg or as per site reqirement as per sample.
76Supply and mixing descaling compound for steam boiler 600 Kg/hr per sample complete all as directed by Engr-in-Charge.
77M&L for dismentaling/opening of old damage heary duty MS pipe fittings from bilers of any shape/size and replacement with new as heavy duty MS pipe fitting as per site requirement including necessary threading, welding work, flange, gasket of any size with nut bolts complete all as directed by Engr-in-Charge
78S & ftriplex Spray pump for boiler of cap 24 Ltrs /hr.
79S & F Gland washer HTN008N for boiler
80S & F valve assembly HTB/ VA for boiler
81S & FPVC washer for valve gauge HTB/002

AI Tender Summary

OUR REF NO 35986718
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 12 Lakhs
LAST DATE 13-03-2023
Authority
Authority Name Military Engineer Services
Work Description Repair And Servicing Of Fan Coil Units ( Fcu ) , Boilers, Pipelines And Allied Items In The Aor Of Ge 864 Ews -M&L For Dismantling Of Centralized Hot Water Generators For Servicing Of Capacity 70000 - 100000 Kcl / Hr By Disconnection Of All Water And Electrical Connectionsisolatingburner Unit Assemblyfrom Main Boiler Unit Forrepair Workand Reassembling, Testing Of The Same Complete All As Specified And Directed By Engr-In Charge.Note:- Spares Shall Be Measured And Paid Under Respective Item ) 2 S & F In Replacement Nozzle Of Size2.5 -4.5 Gph At 70 Degree Suitable For Burner Upto Capacity 100000 Kcal / Hr 3 S & F In Replacement Sequence Controller Suitable For Burner Of Capacity 70000 To 100000 Kcal / Hr. 4 S & F In Replacement Fuel Filter Element Suitable For Burner Of Capacity 70000 To 100000 Kcal / Hr As Per Sample. 5 S & F In Replacement Thermostat Switch Suitable For Burner Of Capacity 70000 To 100000 Kcal / Hr. 6 S & F In Replacementfuel Feed Pump Suitable For Burner Of Capacity 70000 To 100000 Kcal / Hr 7 S & F In Replacement Heavy Duty Wiremesh Bounded Fuel Pipe With Flare Nutboth Ends As Per Sample 8 S & F In Replacement High Temperature Ignition Cable Suitable For Burner Of Capacity 70000 To 100000 Kcal / Hr 9 S & F In Replacement Led Display Unit ( Subzero ) With Control Wiring 10 S & F In Replacement Main Combustion Chamber Including Coils Of Capacity 10000 To 200000 Kcl / Hr.Make 11 Supply And Fixing In Replacementsealed Reciprocating Compressor Unit For 2 Trcomplete, All As Specified And As Directed. 12 Supply And Fixing In Replacementsealed Reciprocating Compressor Unit For 1.5 Trcomplete, All As Specified And As Directed. 13 M&L For Servicing Ofac Plant Installed At Various Installation Cleaning Of Condensing Unit Checking Of All Wiring If Found Damaged Repalce The Damage All Wiring Any Type As Per Existing Complete All As Directed By Engr-In-Charge. 14 S&F In Repacement Of Digital Control Panel / Remote Control Of Package Type Ac Plant Instaalled At Sand Model Room As Per Site Requirement Or As Per Sample Complete As Directed By Engr-In-Chagre. 15 Supply And Filling Of Refrigerant Of R 410-A In Cooling Plant Installed At Installation. 16 Supply And Filling Of Refrigerant Of R 22 In Cooling Plant Installed At Installation.Note : ( Refrigerant Should Be In The Packing Of 450 Gm Tin ) 17 Supply And Fixing In Replacement Replacement Of Compressor A Type Suitable For Refrigerators Of Capacity 165-180 Ltrs. 18 Supply And Fixing In Replacement Replacement Of Compressor B Type Suitable For Refrigerators Of Capacity 190-240Ltrs . 19 Supply And Fixing In Replacement Replacement Of Compressor C Type Suitable For Refrigerators Of Capacity 240-410Ltrs . 20 Supply And Fixing In Replacement Replacement Of Compressor 411 Kcn / 415 Kcn Suitable Fordeep Freezer Of Capacity 260-600 Ltrs . 21 Supply And Fixingin Replacement Printed Circuit Board For Split Type Non Inverter / Inverter Acoperatingathot & Cold Mode Of Capacity 1.5 / 2T. 22 Supply And Fixing In Replacement Starting Capacitors 36-200Mfd 6 Pin / 4 Pin Complete All As Specified And As Directed 23 Supply And Filling Of Refrigerant R-134 ( A ) / Hydro Carbon Blend / R-600 ( A ) Including Nitrogen Flushing , Vaccumizationand Pressure Testing Complete All As Directed. 24 Supply Only Teflon Tape 15 Mm X 15 Mtr 25 Supply Only Pvc Insulation Tape15 Mm X 5 Mtr 26 Supply Only Aaa Size Battery 1.5 Volt. 27 Supply & Fix Indoor Unit Blower Motor With Blower 1.5 Tr / 2 Tr Airconditioner Any Type & Any Make As Per Sampleincluding Inverter Model 28 Supply & Fix Outdoor Unit Fan Motor With Fan1.5 Tr / 2 Trairconditioner Any Type & Any Make As Per Sampleincluding Inverter Model 29 Supply Only Pvc Frls Unsheathedcopperer Conductor Single Core6 Sqmm. 30 Supply Only Remote Control For 1.5 / 2.0 Tr Inverter / Nonnverter Airconditioner Of Any Type & Make As Per Sample 31 M&L Dismantling The Steam Boiler Coil & Descaling Of Steam Boiler 600Kg / Hr By Opening Of Boiler Coilcover From Theboth Sides Including Disconnecting Ofinlet And Outlet Water Connectionsof Theboiler. Closing Both Side Of Coil And Circulating The Descaling Compound Solutionin Tubes Of Boiler Through The Separate Circulatingpump And Allow The Descaling Solution To Hold For 1Hr For Chemical Reaction. After The Duration Of 1 Hr Open The Coil Ends And Ensuringthat The Coil Has Been Descaled Upto Max Clean Range , Then Closingboth Theends Of The Coil And Circulating Clean Water Inthe Tubes Of Boiler And Draining It Out, The Process Will Be Continued Till The Satisfaction Of Engr-In-Charge Then Refixing The Coil Inside The Chamber Complete With All Fixing Material Required At Site: 32 Supply & Fixing In Replacement Of Photo Cell Complete With Holder. Model-8205. 33 Supply & Fixing In Replacement Of Ignition Transformer ( 14500V ) . 34 Supply & Fixing In Replacement Of Pressure Gauge 4 Dia Connection Centre Back Mount, Dial Range - 20 Kg To 25 Kgas Per Sample Complete All As Directed By Engr-In-Charge. 35 Supply & Fixing In Replacement Of Temperature Gauge Dia 2Connection Centre Back Temperature Roadas Per Sample Complete All As Directed By Engr-In-Charge. 36 S&F In Repacement Of Electric Hooter For Boiler 600 Kg / Hrsas Per Sample Complete All As Directed By Engr-In-Charge. 37 Supply & Fixing In Replacement Of Heavy Duty Steam Pressure Gate / Ball Valve 15 To 25 Mm Diaas Per Sample Complete All As Directed By Engr-In-Charge. 38 Supply & Fixing In Replacement Of Heavy Duty Nrv Valve 15 To 25 Mm Dia, As Per Sample Complete All As Directed By Engr-In-Charge. 39 Supply & Fixing In Replacement Of Copper Tube Dia 8 Mm / 12 Mmas Per Sample Complete All As Directed By Engr-In-Charge. 40 Supply & Fixing In Replacement Of Heavy Duty Inlet / Outlet Hose Pipe With Wire Mesh Of Any Size And Any Lengthas Per Sample Complete All As Directed By Engr-In-Charge. 41 M&L For Rewinding Of Burnt Motor From Respective Laundry Machinesby Disconnecting All Electrical And Mechanical Connections And Reassembling, Testing Of The Same After Carrying Out Rewinding Of Motorofunder Mentioned Capacity Single / Three 3Ph 415Volt, 50Hz With Supper Enamelled Copper Wire Having Same Gauge After Taking Out Old Burnt Winding Including Replacement Of Bearing Complete And All As Specified:--1Hp To 2 Hp 42 M&L For Rewinding Of Burnt Motor From Respective Laundry Machinesby Disconnecting All Electrical And Mechanical Connections And Reassembling, Testing Of The Same After Carrying Out Rewinding Of Motorofunder Mentioned Capacity Single / Three 3Ph 415Volt, 50Hz With Supper Enamelled Copper Wire Having Same Gauge After Taking Out Old Burnt Winding Including Replacement Of Bearing Complete And All As Specified:--3Hp To 5 Hp 43 M&L For Rewinding Of Burnt Motor From Respective Laundry Machinesby Disconnecting All Electrical And Mechanical Connections And Reassembling, Testing Of The Same After Carrying Out Rewinding Of Motorofunder Mentioned Capacity Single / Three 3Ph 415Volt, 50Hz With Supper Enamelled Copper Wire Having Same Gauge After Taking Out Old Burnt Winding Including Replacement Of Bearing Complete And All As Specified:--7.5 Hp To 10 Hp 44 M&L For Rewinding Of Burnt Motor From Respective Laundry Machinesby Disconnecting All Electrical And Mechanical Connections And Reassembling, Testing Of The Same After Carrying Out Rewinding Of Motorofunder Mentioned Capacity Single / Three 3Ph 415Volt, 50Hz With Supper Enamelled Copper Wire Having Same Gauge After Taking Out Old Burnt Winding Including Replacement Of Bearing Complete And All As Specified:--12.5 Hp To 20 Hp 45 Supply & Fixing In Replacement Of V Belt Forwasher Extractor Of Capacity - 60 Kg, As Per Sample Complete All As Directed By Engr-In-Charge. 46 Supply & Fixing In Replacement Of Main Drain Valve ( Actuator Butterfly Valve ) Forwasher Extractor Of Capacity - 60 Kg, As Per Sample Complete All As Directed By Engr-In-Charge. 47 Supply & Fixing In Replacement Of Main Water Inlet Valve ( Actuator Butterfly Valve ) Forwasher Extractor Of Capacity - 60 Kg As Per Sample Complete All As Directed By Engr-In-Charge. 48 Supply & Fixing In Replacement Of Single Solenoid Valve Forwasher Extractor Of Capacity - 60 Kg, As Per Sample Complete All As Directed By Engr-In-Charge. 49 Supply & Fixing In Replacementof Display Controller Forwasher Extractor Of Capacity - 60 Kg, As Per Sample Complete All As Directed By Engr-In-Charge. 50 Supply & Fixing In Replacement Of Door Gasket Forwasher Extractor Of Capacity - 60 Kg, As Per Sample Complete All As Directed By Engr-In-Charge. 51 Supply & Fixing In Replacement Of Hose Pipe Of Dia 4 Forwasher Extractor Of Capacity - 60 Kg, As Per Sample Complete All As Directed By Engr-In-Charge. 52 Supply & Fixing In Replacementof V Belt For Washer Extactor Of Capacity - 30 Kg, As Per Sample Complete All As Directed By Engr-In-Charge. 53 Supply & Fixing In Replacementof Silicon Oil Seal With Circlip & O Ring For Slucing Machine Of Capacity - 30 Kg, As Per Sample Complete All As Directed By Engr-In-Charge. 54 Supply & Fixing In Replacement Of Main Drive V Belts For Drying Tumbler As Per Sample Complete All As Directed By Engr-In-Charge. 55 Supply & Fixing In Replacement Of Automatic Steam Inlet Valve For Drying Tumbler As Per Sample Complete All As Directed By Engr-In-Charge. 56 Supply & Fixing In Replacement Of Contactor For Drying Tumbleras Per Sample Complete All As Directed By Engr-In-Charge. 57 Supply & Fixing In Replacement Of Solenoid Valve For Vaccum Ironing Machine As Per Sample 58 Supplying, Mixing And Filling Of Mono Ethylene Glycol Concentrate Along With The Necessary Additives And Inhibitor In Cognition, Required For Operation Of Plant And Network. The Mixing Freezing Temperature Shall Be Minus 10 Degree C All As Sprecified And Directed By Engr-In-Charge. 59 Supply And Mixing Hydro Caloric Acid ( Hcl ) Concentrate. 60 Supply And Fixing In Replacement Under Mentioned Items For Oil Fired Incinerator Model Py-Vs-75As Per Sample Complete All As Directed By Engr-In-Charge.:- Photo Cell 61 Fuel Filter Element Per Sample Complete All As Directed By Engr-In-Charge. 62 Thermo Couple K Type Per Sample Complete All As Directed By Engr-In-Charge. 63 Pressure Gauge 0-40 Kgs / Cm 2-1 / 4 Bsp Per Sample Complete All As Directed By Engr-In-Charge. 64 Electrode Front Pair Per Sample Complete All As Directed By Engr-In-Charge. 65 S&F In Replacement Of Solenoid Valve Of Incinerator As Per Sample Complete All As Directed By Engr-In-Charge. 66 Electrode Rear Pair As Per Sample Complete All As Directed By Engr-In-Charge. 67 Sequence Controller As Per Sample Complete All As Directed By Engr-In-Charge. 68 Oil Seal For Fuel Pump As Per Sample Complete All As Directed By Engr-In-Charge. 69 Ht Cable As Per Sample Complete All As Directed By Engr-In-Charge. 70 Spider Lo-70 ( Rubber Bush ) As Per Sample Complete All As Directed By Engr-In-Charge. 71 S&F In Replacement Of Main Steam Inlet Valve Automaticfor Washer Extractor 60 Kg Aper Sample Complete All As Directed By Engr-In-Charge. 72 S&F In Replacement Of Thermocouple For Washer Extractor 60 Kgas Per Sample Complete All As Directed By Engr-In-Charge. 73 Supply And Mixing Industrial Salt In Water For Descalingfor Steam Boiler 600 Kg / Hr 74 Supply And Fixing Fuel Feed Pump Suitable For 3 Three Phase Burner Assembly Of Capacity 100000 K Cal To 400000 As Per Sample Complete All As Directed By Engr-In-Charge. 75 S&F In Replacement Of Touch Screen Hmi For Washer Extractor 60 / 30 Kg Or As Per Site Reqirement As Per Sample. 76 Supply And Mixing Descaling Compound For Steam Boiler 600 Kg / Hr Per Sample Complete All As Directed By Engr-In-Charge. 77 M&L For Dismentaling / Opening Of Old Damage Heary Duty Ms Pipe Fittings From Bilers Of Any Shape / Size And Replacement With New As Heavy Duty Ms Pipe Fitting As Per Site Requirement Including Necessary Threading, Welding Work, Flange, Gasket Of Any Size With Nut Bolts Complete All As Directed By Engr-In-Charge 78 S & Ftriplex Spray Pump For Boiler Of Cap 24 Ltrs / Hr. 79 S & F Gland Washer Htn008n For Boiler 80 S & F Valve Assembly Htb / Va For Boiler 81 S & Fpvc Washer For Valve Gauge Htb / 002
Basic Detail
Tender No 864/WS-73/2022-23
Bidding Type Tender
Location
City Srinagar
State Jammu And Kashmir
Key Dates
Publish Date 06 Mar 2023
Submission Date 13 Mar 2023
Open Date 15 Mar 2023
Finance
Tender Value 12 Lakhs
Tender Fee 500
EMD 24000
Exemption Not Available
Document List
e989564b-3d7c-43da-8d28-b61c609d208b.html
73TENDER.pdf
BOQ_647527.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Mar 06, 2023
11:30 IST

Tender Published

Tender notice published.

Completed
Mar 06, 2023
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Mar 13, 2023
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Completed
Mar 13, 2023
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Mar 15, 2023

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

e989564b-3d7c-43da-8d28-b61c609d208b.html

pdf

73TENDER.pdf

xls

BOQ_647527.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders