Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Demolition of cement concrete un reinforced in ground floor and paving n exc 15cm thick (below or above ground level) complete all as specified and directed. |
| 2 | Demolition of Cement Concrete (unreinforced) of any description & in any position not otherwise specifically provided for complete all as specified and directed. |
| 3 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off premises complete all as specified and directed. |
| 4 | M&L for PCC 1:3:6 Type C-2 using 40 mm graded stone aggregate in foundation filling and mass concrete complete all as specified and directed. |
| 5 | M&L for PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in sub base flooring average 25 mm thick surface finished even andrough (as in levelling course) to receive the topping layer complete all as specified and directed. |
| 6 | M&L for non skid ceramic coloured tiles of design as approved 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including 15 mm thick screed bed in cement mortor 1:6 complete all as specified and directed. |
| 7 | M&L for non skid ceramic coloured tiles of design as approved 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including 15 mm thick screed bed in cement mortor 1:6 complete all as specified and directed. |
| 8 | M&Lfor glazed ceramic coloured tiles 350 x 250 x 7 mm / 450 x 350 x 7 mm thick on vertical surface such as dado / skirting / risers to steps etc jointed in neat cement slurry and pointed in white or coloured cement to match surface of tiles over and including rendering 10 mm thick in cement mortor 1:4 complete all as specified and directed. Note-The size of tiles (except thickness) may be varied during execution without any price adjustment. |
| 9 | M & L coloured vitrified tiles Light shade 10 mm thick (square/rectangular) polish area of each tiles n exc 0.36 Sqm coloured cut to required size set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles as in floor incl 15 mm thick screed bed in CM 1:4 complete all as specified and directed. |
| 10 | M & L coloured vitrified tiles 10 mm thick (square/rectangular)polish area of each tiles n exc 0.36 Sqm coloured cut to required size set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles but in vertical surfaces incl 10 mm thick rendering in CM 1:3 complete all as specified and directed. |
| 11 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 12 | M&L for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and directed. |
| 13 | Taking down cement or cement lime plaster, of any description, on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 14 | M&L for Rendering 15 mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces, finished even and smooth (without using extra cement) complete all as specified and directed. |
| 15 | M&L for rendering 5 mm thick in CM 1:3 on RCC ceiling surface and finished even and smooth with out using extra cement complete all as specified and directed . |
| 16 | M&L for applying 2mm thick Birla / JK Putty in two layers on newly plastered walls surfaces making absolutely even and smooth, rubbing with sand paper complete all as specified and directed |
| 17 | M&L for applying two coats of oil bound distemper on wall or concrete surfaces over & including a coat of primer on prepared surfaces including, rubbing with sand paper complete all as specified and directed. |
| 18 | M&L for preparation of newly plastered surfaces of walls and apply three coat of white wash complete all as specified and directed. |
| 19 | M&L for preparation of newly plastered surfaces of ceilings and apply three coat of white wash complete all as specified and directed. |
| 20 | M & L for two coats of cement based paint over a coat of primer on new plastered surface of walls including preparation of surface complete all as specified and directed. |
| 21 | Taking down eaves gutters and rain water pipes of any size or pattern including all fittings etc complete all as specified and directed. |
| 22 | S&F 110mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed. |
| 23 | S&F 110mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to walls complete all as specified and directed. |
| 24 | S&F 110mm bore PVC (SWR) bends any radius complete all as specified and directed. |
| 25 | S&F 110mm bore PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed. |
| 26 | S&F 110mm bore PVC (SWR) vent cowl complete all as specified and directed. |
| 27 | S&F 75mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed. |
| 28 | S&F 75mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to walls complete all as specified and directed. |
| 29 | S&F 75mm bore PVC (SWR) bends any radius complete all as specified and directed. |
| 30 | S&F 75mm bore PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed. |
| 31 | S&F 75mm bore PVC (SWR) vent cowlcomplete all as specified and directed. |
| 32 | S&F Stack clamps made out of 50x5 mm flat iron, 16mm dia round iron stays including bolts & nuts and securing ends of stays to wall or roof for 110 mm PVC pipe complete all as specified and directed. |
| 33 | S&F Stack clamps made out of 50x5 mm flat iron, 16mm dia round iron stays including bolts & nuts and securing ends of stays to wall or roof for 75 mm PVC pipe complete all as specified and directed. |
| 34 | Dismantling wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards/slabs /blankets, any thickness, including cover fillets complete all as specified and directed. |
| 35 | S&F 12 mm thick plain Gypsum Board False Ceiling with GI frame including all necessary drilling cutting to fix electric items complete all as specified and directed with following:-(a) GI Grid channel 30x25x20 mm of 24 gauge fixed with rawl plug and screw 450 mm centre to centre alongwith perimeter walls.(b) GI channel made to shape 50x40x40 mm of 24 gauge placed @ 600 mm centre to centre from perimeter at wall except long wall (in one span). (c) GI intermediate runners of size 45x10x10 mm of 24 gauge fixed @ 1200 mm centre to centre leaving frame of one side walls (in other span).(d) GI sheet 25 mm wide and 20 mm gauge suspended fixed with steel fastner to roof ceiling and 1200 mm centre to centre including pluging of RCC Slab. (e) 12 mm thick gypsum board filling joints with POP and finishing complete with two coat of plastic emulsion paint over one coat of primer on ceiling. |
| 36 | S & Frotational moulded polyethylenewater storage tank (cylindrical vertical with closed top) 500 litres capacity hoisted and fixed in position including dismantling of old u/s water tankand removing to storecomplete all as specified and directed |
| 37 | S & Frotational moulded polyethylenewater storage tank (cylindrical vertical with closed top) 1000 litres capacity hoisted and fixed in position including dismantling of old u/s water tank and removing to store complete all as specified and directed |
| 38 | S&F ball valves for 20 mm bore dia of pipe high pressure of PTMT with Epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight 210 gms) complete all as specified and directed. |
| 39 | S&F ball valves for 25 mm bore dia of pipe high pressure of PTMT with Epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight 455 gms) complete all as specified and directed. |
| 40 | S&F in repairs ball valves for 20 mm bore dia of pipe high pressure of PTMT with Epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight 210 gms) complete all as specified and directed. |
| 41 | S&F in repairs ball valves for 25 mm bore dia of pipe high pressure of PTMT with Epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight 455 gms) complete all as specified and directed. |
| 42 | M&L for Disconnecting existing tanks 500 litres capacity, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately) complete all as specified and directed. |
| 43 | M&L forDisconnecting existing tanks 1000 litres capacity, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately) complete all as specified and directed. |
| 44 | S & F in repair PVC Tank cover for 500 Ltr capacity fixed in position with nuts and bolt complete all as specified and directed |
| 45 | S & F in repair PVC Tank cover for 1000 Ltr capacity fixed in position with nuts and bolt complete all as specified and directed |
| 46 | S&F in repair Gun metal globe or gate valves with iron wheel head screwed both ends (ISI marked)for Iron/ PP-R pipe of 20 mmbore dia of pipe complete all as specified and directed. |
| 47 | S&F in repair Gun metal globe or gate valves with iron wheel head screwed both ends (ISI marked) for Iron/ PP-R pipe of 25 mmbore dia of pipe complete all as specified and directed. |
| 48 | S&F in repair PP-R Gate valves (brass insert)for PPR Pipes of 20 mmbore dia of pipe complete all as specified and directed. |
| 49 | S&F in repair PP-R Gate valves (brass insert)for PPR Pipes of 25 mmbore dia of pipe complete all as specified and directed. |
| 50 | M&L Cutting holes into or through brick walls built in mud mortar and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required superficial area n exc 150 sqcm complete all as specified and directed. |
| 51 | Taking up or down steel tubing and connections including cleaning if refixingrequired for 15 mm bore of pipe complete all as specified and directed. |
| 52 | Taking up or down steel tubing and connections including cleaning if refixingrequired for 20 mm bore of pipe complete all as specified and directed. |
| 53 | Taking up or down steel tubing and connections including cleaning if refixingrequired for 25 mm bore of pipe complete all as specified and directed. |
| 54 | S & F 15 mm bore 3 layer PP-R pipes SDR 7.4 & SDR 11 UV stablised and anti microbial welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded PP-R fittings complete to walls, ceilings or in floors complete all as specified and directed. |
| 55 | S & F 20 mm bore 3 layer PP-R pipes SDR 7.4 & SDR 11 UV stablised and anti microbial welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded PP-R fittings complete to walls, ceilings or in floors complete all as specified and directed. |
| 56 | S & F 25 mm bore 3 layer PP-R pipes SDR 7.4 & SDR 11 UV stablised and anti microbial welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded PP-R fittings complete to walls, ceilings or in floors complete all as specified and directed. |
| 57 | Making connection of PPR distrubtion branch with PPR main of following outer dia of pipe 16 to 40mm size by providing and fixing tee including cutting and making fusion joint etc complete all as specified and directed. |
| 58 | Refixing old steel tubing and connections in new or old position (wall, floor, ceiling etc) of 15 mm bore of pipe complete all as specified and directed. |
| 59 | Refixing old steel tubing and connections in new or old position (wall, floor, ceiling etc) of 20 mm bore of pipe complete all as specified and directed. |
| 60 | M&L for Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth in Bricks/ stone Masonary wall complete all as specified and directed. |
| 61 | M&L in repairsWater proofing treatment on \"Non approachable / non accessible and approachable roof\" surface (Horizontal & Vertical surfaces) in following sequence through manufacturer / authorized applicator of the manufacturer including taking down of existing roof treatment,properly cleaning & drying the concrete surfaces complete all as specified and directed. Applying a coat of oxidised bitumen based solvent primer @ 0.3 Kg / Sqm |
| 62 | All as per S No 61 above but Applying evenly a tack coat of industrial bitumen 85/25 grade @ 1.2 kg/ Sqm incl cleaning surfaces. |
| 63 | All as per S No 61 above but Laying unrolled over the bitumen coated surface, polymeric water proofing membrane Hyperplas standard wt not less than 3kg /Sqm with 100 mm over laps shall be sealed by flame as per manufacturers instruction. |
| 64 | All as per S No 61 above but Applying two coats of bituminous aluminium paintincluding preparation complete |
| 65 | M&L for PCC 1:1.5:3 type A-0 (Using 12.50mm gradedstone aggregate) in roof padding/kerbs/sunken slab etc complete all as specified and directed. |
| 66 | M&L10 mm thick rendering on roof surfaces/ concrete surface in CM 1:3 finishing even and smooth complete all as specified and directed. |
| 67 | Excavating in trenches not exceeding 1.5 meter wide and not exceeding1.5 meter in depth for foundation for erection of poles, stays, laying cables, stays etc and getting out in hard / dense soil all as specified and directed. |
| 68 | Excavating in trenches not exceeding 1.5 meter wide andexceeding1.5 meter and not exceeding 3meter in depth for foundation for erection of poles, stays, laying cables, stays etc and getting out in hard / dense soil all as specified and directed. |
| 69 | Returning filling in excavated earth work including spreading, levelling, watering and well ramming in layers n.exc 25cm thick in any stratacomplete all as specified and directed. |
| 70 | Removing excavated soil to a distance n.exc 50m, depositing where directedat a level n.exc 1.5M above the starting point complete all as specified and directed. |
| 71 | Supply/ Lay dry river sand / m -sand in trenches for cable protection complete all as specified and directed.Note : Punned thickness only will be measured & Paid |
| 72 | M & L for graded coarse aggregate (broken stone or boulders) of size 40 mm in sub - station yard for layingcomplete all as specified and directed. |
| 73 | M & L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate including use and waste of form work of concrete for pole and stay foundation. |
| 74 | M & L for PCC 1:3:6 type C-2 using 40 mm graded stone aggregate including use and waste of form work for pole filling/ any description complete all as specified and directed. |
| 75 | M & L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate including use and waste of form work for pole filling/ any description complete all as specified and directed. |
| 76 | S & F intrench/on wall in repairs GItubing light grade for road crossing and cable protection of the 80 mm dia complete all as specified and directed. |
| 77 | All as per item No 76 above but 100 mm dia |
| 78 | Dismantling old and unserviceable pre stressed concrete /Steel polesany type including breaking cement concrete complete, Material and erection of steel tubular swaged pole with cast iron base plate finial tapper plug, bolts nuts and screws and specified type 410-SP-55 ( 11mtr long) in truly vertical position 1.5 m length of pole above ground level shall be painted with two coats of synthetic enamel paint in strips of 30 cm width, black and yellow alternatively and painting with two coats of aluminum paint over a coat of red oxide primer on rest part of pole and its connected parts complete all as specified and directed by engir-in charge. Note- Excavation and PCC shall be measured and paid seperately |
| 79 | M & L for Prestressedconcretepole,11.0 metres long.152mm x 152mm at top and 152mmx260mmat bottom, class 9 complete all as specified and directed. |
| 80 | S & F in repairs Galvanaised Iron cross arms channel, bracing, support, clamps etc fabricated structured steel, sections, including nuts, bolts, washers etc and cutting to required length beat to any shape drilling holes, fixed on poles or jointed by means of elect welding complete incl painting with 2 coats of aluminum paint over a coat of red oxide primer after preparation of surfaces incl taking down / dismantling the old items complete all as specified and directed. |
| 81 | Dismantling old unserviceable stay assy complete, material and labour for new stay assembly complete with 20 mm dia stay rod with accessories shown in electric plate No 01 inclstay clamp, (loop insulator, stay wire, excavation and concrete measured seperately)complete all as specified and directed. |
| 82 | S & F in repairs Disc type porcelain vitreous, brown or white insulator suitable for 11 KV HT working Pressure of size 145 mm height, 255 mm dia , including. one galvanised mild steel spindle, two galvanised iron washer and one GI nut complete all as specified and directed. |
| 83 | S & F in repairs Pin type porcelain vitreous,brown of white insulator suitable for 11KVHT of working pressure of size 150mm height, 150mm dia, including one galvanised mild steel spindle, two galvanished iron washer and one GI nut complete all as specified and directed. |
| 84 | S & F in repairs cable jointing kit for 11KV grade cable for Outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 120 to 185 sqmm. |
| 85 | S & F in repairscable jointing kit for 11KV grade cable for Indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 120 to 185 sqmm. |
| 86 | S & F in repairs cable jointing kit for 11KV grade cable for Straight through joint heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 120 to 185 sqmm. |
| 87 | S & F in repairs cable jointing kit for 11KV grade cable for Outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 50 to 95 sqmm. |
| 88 | S & F in repairscable jointing kit for 11KV grade cable for Indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 50 to 95 sqmm. |
| 89 | S & F in repairs cable jointing kit for 11KV grade cable for Straight through joint heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 50 to 95 sqmm. |
| 90 | Supply & Lay , testing and commissioning in repairs XLPE cable , PVC insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cable, heavy duty with aluminium conductor 11000 Volts grade (earthed), 3 core 95 sqmm laid in trenches / floor / duct / fixed on poles / through GI tubing in different locations / areas complete all as specified and directed. |
| 91 | Supply & Lay , testing and commissioning in repais XLPE cable , PVC insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cable, heavy duty with aluminium conductor 11000 Volts grade (earthed), 3 core 120 sqmm laid in trenches / floor / duct / fixed on poles / through GI tubing in different locations / areas complete all as specified and directed. |
| 92 | Repairing / Servicing the Air break isolating switch HT 33 KV/11 KV 200/400 Amps by replacingthe defective major spares including provn of minor bolts nuts etc complete all as specified and directed.Note :- Major spare will be measured & paid seperately under relevant item of Sch\"A\" item No. 27 |
| 93 | Supply only 33 KV/11 Airbreak switch Male contact/moving Contact Blade all as directed. |
| 94 | All as per item No 93 above but Female contact/Fix Contact Jaw |
| 95 | All as per item No 93 above but Rotating contactor pipe 200A/400 A |
| 96 | All as per item No 93 above but MS jumper carrier |
| 97 | All as per item No 93 above but Back Connector plate |
| 98 | S & F in repairs lighting arrestor Zinc oxide gap less type , station class suitable for 11 KV / 65 KA complete with all fittings complete all as specified and directed. |
| 99 | M & L preparation of old painted surfaces ofHT 33 MRS at GOS consisting ofSteel poles / ISMBs, cross arms, GOD pipe,clamps etc., having of any descriptionand applying one coat of aluminium paint manually all as directed complete all as specified and directed.Note:-(a) This rate inclusive of painting all minor items such as clamps, brackets, nuts, bolts and washers which is not particularly mentioned in this item. (b)This painting work will be carried out during Holidays only to avoid elect shut down. |
| 100 | M & L for removing vegitation, grass, scrubs and bushes growing in Sub station yard along with fancing by mannually / mechanically and keep the sub station yard neat and clean complete all as specified and as directed. Note :- Unit rate quoted deemed to include to keep the installation neat and clean through out the period of contract and each cleaning will be measured and paid separately. |
| 101 | S & F in repairs insulating rubber mat ISI marked of size 1 m x 2 m x19mm suitable for 11 KV at 33 KV MRS Old Air Field |
| 102 | Taking down carefully the existing 33/11 KV power transformer of capacity 1.6 MVAby disconnectingHT overheadconnection/underground cables and earth strips etc. from MRS using suitable capacity of crane or by any other method irrespective of type of approach available, loading in vehicle, transportation to workshop for repairs and unloading carefully. Reloading the tranformer after repairs and testing of transformer;transportation to site and unloading including placing at given position and re-commissioning complete all as specified and directed by Engr-in-charge. Note : All the T&P required for disonnection, connection, loading and loading including necessary petty items like bolts, nuts etc will be arranged by the contractor and rates for the same deem to be included in the rates quoted. |
| 103 | Taking down carefully the existing 11KV/433 V distribution transformer of capacity 63 KVA to 315 KVAby disconnectingHT overheadconnection/underground cables and earth strips etc. from any substation / locations using suitable capacity of crane or by any other method irrespective of type of approach available, loading in vehicle, transportation to workshop for repairs and unloading carefully. Reloading the tranformer after repairs and testing of transformer;transportation to site and unloading including placing at given position and re-commissioning complete all as specified and directed by Engr-in-charge. Note : All the T&P required for disonnection, connection, loading and loading including necessary petty items like bolts, nuts etc will be arranged by the contractor and rates for the same deem to be included in the rates quoted. |
| 104 | M & L for repairs toTransformer step down 11KV/0.433 KV any type of capacity 63 KVA to 315 KVA, after dismantling the transformer body carefully, opening the top cover of Transformer for inspection /repair, drain out the transformer oilfrom the tank complete, taking out the core and winding assy by disconnecting the internal connections, removing the carbon/sludge deposit in transformer housingcore, renewal/replacement of u/s rubber bushes and washers , replacement of tap changer winding and thimbles, replacement of silica gel, replacement of top cover gasket set including pasting with pasting material, replacement of worn out nut and bolts, replacement of unserviceable LT & HT bushes, cutting the burnt out winding and re-winding the same with suitable size of super enamelled copper wire as per existing guage, insulating the winding connection by using fire proof sleeve and fire proof tape, warnishing the coil, keeping the coils in electric oven chamber for 24 hrs to remove the moisture, Painting of complete transformer body from outside and inside by weather proof type using spray gun, Marking of MES/SM Number etc, replacement of conservator tank glass, re-intalling the core and winding inside properly, making the all connection with suitable copper lugs, refilling of dehydrated transformer oil including dehydration, reinstalling the top cover after cleaning and painting of housing, conservator tank, expulsion vent etc, Meggering the LT and HT side of the Transformer and testing complete all as specified and directed.Note :- Winding wire including labour for making of coils and LT/HT bushes will be measured & paid seperately. |
| 105 | All as peritem No 104 above but of capacity 11 KV/0.433 KV, 315 KVA to 650 KVA complete all as specified and directed. |
| 106 | All as per item No 104 above but of capacity 11 KV/0.433 KV, 315 KVA to 650 KVA complete all as specified and directed. |
| 107 | Supply and filling of fresh transformer power oil of BDV not less than 50 KV for topping up of reduced level of transformer due to evaporation/ leakage/losses due to dehydration in distribution 11 KV transformer /Distribution transformer 63 to 650 KVA or for replacement complete including removing of old unservicable transformer oil complete all as specified and directed. |
| 108 | M & L for conducting oil filtration by stream line / Vacuum type filter machine to remove the moisture/carbon particles to improve required BDV of oil 50 to 60 KV for 1 min for min for distribution transformer incl routine testing after filtration for any capacity of transformers/CT/PT units all as directed. (Note : The contractor shall change the filter assy before starting the filtration of power/ distribution transformer of any capacity in presence of Engr In charge) |
| 109 | Material and labour for replacement of brass terminal rod with nuts,bolts washers & bushings suitable for HT side of the transformer of any make and capacity from 63KVA to 315 KVA complete all as specified and directed. |
| 110 | All as peritem No 109 above but LT side. |
| 111 | Material and labour for replacement of 33 KVbushings for capacity of 1.6 MVA 33/11 KVA transformer complete all as specified and directed. |
| 112 | Material and labour for replacement of 11 KV bushings for capacity of 1.6 MVA 33/11 KVA transformer complete all as specified and directed. |
| 113 | Material and labour for repalcement of 33 KV bushing stud (copper) for capacity of 1.6 MVA 33/11 KV transformer complete all as specified and directed. |
| 114 | Material and labour for repalcement of 11 KV bushing stud (copper) for capacity of 1.6 MVA 33/11 KV transformer complete all as specified and directed. |
| 115 | Material and labour for cleaning, treatment and reassembling of core for 1.6 MVA 33/11 KV transformer complete all as specified and directed |
| 116 | Material and labour for arching horn (33KV) double gap clamp complete all as specified and directed |
| 117 | Material and labour for arching horn (11KV) double gap clamp complete all as specified and directed |
| 118 | Material and labour for 33 KV Off load Tap switch 5 position (+5 to -10) complete all as specified and directed |
| 119 | Material and labour for repalcement of gasket for complete transformer all as specified and directed |
| 120 | Material and labour for repalcement of silica get breather for transformer 1.6 MVA complete all as specified and directed |
| 121 | Material and labour for dial type therometer 6 inch with DC complete for 1.6 MVA 33/11 KVA transformer complete all as specified and directed. |
| 122 | Material and labour for replacement of brass terminal rod with nuts,bolts washers & bushings suitable for HT side transformer ofcapacity of 1.6 MVA 33/11 KVA complete all as specified and directed. |
| 123 | Material and labour for replacement of brass terminal rod with nuts,bolts washers & bushings suitable for HT side of the transformer of any make and capacity from 315 KVA to 650 KVA complete all as specified and directed. |
| 124 | All as per item 123 above but LT side. |
| 125 | Supply and replacing silica gel breather clear view type including first fill of good quality silica gel of capacity suitable for 63 KVA to 315 KVA transformer complete all as specified and directed. |
| 126 | Supply and replacing silica gel breather clear view type including first fill of good quality silica gel of capacity suitable for 315 KVA to 650 KVA transformer complete all as specified and directed. |
| 127 | M & L for painting using spray paintingthe outer surface of the transformer with one coat of weather proof paint after preparing the surface dust and oil free and cleaning the bushes, name plate etc paint free after painting including writing the MES/SM No with white enamelled paint all as directed for capacity of transformer 63 KVA to 650 KVA (Indoor/outdoor type) complete all as specified and directed. |
| 128 | M & L for painting using spray paintingthe outer surface of the transformer with one coat of weather proof paint after preparing the surface dust and oil free and cleaning the bushes, name plate etc paint free after painting including writing the MES/SM No with white enamelled paint all as directed for capacity of transformer 1.6 MVA complete all as specified and directed. |
| 129 | Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x6mm thick burried directly in ground (earth pit not less than 2.25 m deep below normal ground level, connecting to the Galvanised iron earth lead 32x6mm size, by means of bolts, nuts, check nuts and washers of galvanised iron and 32x6 mm earth lead protected by provision of GI medium grade pipe 40 mm bore including provision of concrete pit in PCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregates with 40 mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4kg/Sqm) and frame of angle iron 25x25x3 mm with lugs-02 Nos and with 6 mm dia MS bar handle made to shape, GI medium grade 20 mm bore pipe for watering perforated at bottom 1.5 meter long placed on top edge of earth plate common salt and charcoal filling, test point with fixing arrangements, funnel wire mesh and earth work in hard/dence soil returning filling in and removal of surplus soil to a distance not exceeding 50 m, all as per electrical plate No 5 of SSR-2010 Part-I and connecting to earth test point complete all as specified and directed. |
| 130 | M&L for replacement off load tap changer for distribution transformer of any make and capacity from 63-650 KVA complete all as specified and directed. |
| 131 | M&L for super enamelled copper conductor wire of suitable gauge and size including making suitable coil bobbins as per existing size and shape with proper insulating materials, spacers, warnishing as per required grade and insulatin and assembling on core, heating the same in oven as per standard procedure at appropriate temerature to obtained desired insulatin level for thepower/ distribution transformer of any capacity / any make complete all as specified and directed. |
| 132 | Material and labour for replacement of bush type insulator white/brown/green working pressure 433 Volts LT side complete all as specified and directed. |
| 133 | M & L for servicing of 33 KV VCB / 11KV VCB / bus couplerby dismantling cleaninggreasing the complete VCB with attached relays bus bar etc insulation testing, setting the contact gap by measuring as required reassembling the VCBand reinstalling back to its original positionchecking and repairing the currentcircuit panel wiring, replacement of new spares as required completeincluding operational testing and commissioning complete all as specified and directed.(Note : New spares will be measured and paid separately under relavent item of this schedule) |
| 134 | M & L for carrying out primary & secondary injection test of 33 KV or 11 KV indoor /outdoor type current transformer (Set of three) of VCB\"s by using standard injection test method and checking the electrical circuits for fault condition, all relay testing andproper functioning incl submittingthe test report complete all as specified and directed. (Note : PIT/SIT for VCB will be carried out in 6 months intervals and each primary & secondary injection test will be measured and paid) |
| 135 | Supply only the Closing coil24/30V DC spares for VCB 11 KV400 A25 KA250MVAas approved by GE. |
| 136 | All as per item No 135 above but Tripping coil 24/30V DC |
| 137 | All as per item No 135 above but Antipumping device 24/30V DC |
| 138 | All as per item No 135 above butEarth Fault and over current relay as per existing and suitable |
| 139 | All as per item No 135 above but Digital type power factor indicator meter |
| 140 | All as per item No 135 above but Digital type Voltmeter / Ammeter 96 x 96 mm size |
| 141 | All as per item No 135 above but LED type indicator lamp assembly |
| 142 | All as per item No 135 above but spout incoming side |
| 143 | All as per item No 135 above but spout outgoing side |
| 144 | All as per item No 135 above but Epoxy insulators bushings for incoming / out going cables / bus bar suppors as per existng size of VCBs |
| 145 | All as per item No 135 above but Gear system assy complete with handle for charging / discharging of VCBs |
| 146 | All as per item No 135 above but Spring charging motor for VCBs |
| 147 | All as per item No 135 above but Over current protection relay as per existing and suitable |
| 148 | All as per item No 135 above butMetering and protection current transformer epoxy/resin filled of 11 KV grade of ratio 100-50/5 class = 5P, 10/1 25 VA draw out type with necessary mounting and connected items. |
| 149 | Painting of two pole stucture consistig of 2 Nos PCC pole 11 M height, 1 no GOS, 1 set support insulators with channels, with all connected clamps,supports etc by preparing the surface and applying two coat of syntheti enamal paint over a coat of primer as per colour code to the metal structure and cement paint to the PCC structures complete all as specified and as directed. |
| 150 | Painting of two pole stucture consistig of 2 Nos (Metal Strucure) 11 M height, 1 no GOS, 1 set support insulators with channels, with all connected clamps,supports etc by preparing the surface and applying two coat of syntheti enamal paint over a coat of primer as per colour code to the metal structure and cement paint to the PCC structures complete all as specified and as directed. |
| 151 | Painting of four pole stucture consisting of 4 Nospole(metal structure) 11 M height, 3 no GOS, 1 set Fuse with channels,1Bus bars 1 No LA etcwith all connected clamps,supports etc by preparing the surface and applying two coat of syntheti enamal paint over a coat of primer as per colour code complete all as specified and as directed. |
| 152 | Painting of four pole stucture consistig of 4 Nospole(PCC) 11 M height, 3 no GOS, 1 set Fuse with channels,1Bus bars 1 No LA etcwith all connected clamps,supports etc by preparing the surface and applying two coat of syntheti enamal paint over a coat of primer as per colour code complete all as specified and as directed. |
| 153 | Supply & fix replacement of silica gel complete all as specified and directed.. |
| 154 | Supply & fixing of petroleum jelly complete all as specified and directed.. |
| 155 | Supply & Fixing in replacement precast PCC cable route indicator duly marked and painted for HT /LT cable of size 80 x 25 x 7.5 CM with suitable size of basecomplete all as specified and as directed. |
| 156 | Supplying & laying ofprecast concrete cable cover, class HV, type 1 peak type size 300mmx180mmx40mm complete all as specified and directed.. |
| 157 | S & F in repair horn gap fuse 11 kv 200 Amps horizontal/vertical type for outdoor use including all connected accessorises complete all as specified and as directed |
| 158 | Supply and install HT 11 KV 3 phase 50 cycles out doortype air break switch suitable for horiandal/Vertical mounting fixed type complete with 9 insulators operating handle and all clamps,nuts,bolts etc of rating upto 200 Amp complete all as specified and as directed. |
| 159 | M&L in repairs danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size complete all as specified and as directed. |
| 160 | Supply and fixing of fuse wire tinned copper of different capacityas per ground requirement complete all as specified and directed.. |
| 161 | M&L for cable fault locator vehicle mounted to locate fault at any type of location with one fault locate at a time complete all as specified and as directed. |
| 162 | M&L for in repairs aluminium conductor steel reinforced complete all as specified and directed to be used as jumpers |
| 163 | M & L for Cutting and trimming of tree branches 5 mtr all around of any size which is coming over the two/four pole structure of 11 KV line by using required tools and plants incl removing trimmed tree branches.(Note : Each cleaning will be measured and paid separetely) |
| 164 | M&L for PVC board of size 30x30 cm with letter written in stickers dully marked the incoming and outgoing cable feeder with suitable size of letters with fixing complete all as specified and directed. Note: Background of the board should be red and letters should be in white colour. |
| 165 | S & F in repairs incl testing of metering & protection current transformer Oil filled out door type of 11 KV capacity ratio 100-50/5 or 200-100/5 class=5P, 10/1 15 VA including dismantling old existing CT complete all as specified and as directed. |
| 166 | Dismantling old and burnt out PT unit 33000/110/220 volts oil filled out door type taking out contact with lead and bushing from the bus barand replacing by new one of same model suitable for 11 KV PT unit incl testing on completion complete all as specified and as directed. |
| 167 | S & F in repairs cable jointing kit for 33 KV grade cable for Outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 120 to 185 sqmm. |
| 168 | S & F in repair horn gap fuse 33 kv (Polymer) 200 Amps horizontal/vertical type for outdoor use including all connected accessorises complete all as specified and as directed |
| 169 | S&F in repair 33 KV disc insulator polymer type with hardware fittings complete all as specfied and directed |
| 170 | S&F in repairs power aluminium bolted type connectors to be fixed on jumpers/aluminum conductors/AB conductors of any size complete all as specified and directed |
| 171 | S&F in repairs of AB conductor of size 100 Sqmm with colour code (RYB) as required on ground for MRS structure complete all as specified and directed |
| 172 | S&F in repairs of 33 KV post insulators complete all as specfied and directed |
| 173 | S&F in repairs of 11 KV post insualtors complete all as specified and directed |
| 174 | Boring of holes horizontally for laying of 80mmdia pipe (minimum depth 0.60 Mtr from top level) under road, Pavement, hard standing complete all as specified and directed. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail