Tender For Provision Of New Substation For Shifting Of Electric Equipment Outside Issa Lab Bldg Bldg No P-147 At Metcalfe House Under Ge I Rnd Delhi, delhi-Delhi

Military Engineer Services-MES has published Tender For Provision Of New Substation For Shifting Of Electric Equipment Outside Issa Lab Bldg Bldg No P-147 At Metcalfe House Under Ge I Rnd Delhi. Submission Date for this Tender is 06-03-2023. Substation Tenders in delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

35972937
Corrigendum : Tender For Provision Of New Substation For Shifting Of Electric Equipment Outside Issa Lab Bldg Bldg No P-147 At Metcalfe House Under Ge I Rnd Delhi
Open Tender
Indian
Delhi
delhi
06-03-2023

Tender Details

Provision Of New Substation For Shifting Of Electric Equipment Outside Issa Lab Bldg Bldg No P-147 At Metcalfe House Under Ge I Rnd Delhi

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 13-Feb-2023 Corrigendum01 Date 21-02-2023
2 13-Feb-2023 Corrigendum02 BOQ 21-02-2023
3 21-Feb-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 28-02-2023
4 28-Feb-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 06-03-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 88000.0 /-
Tender Value
Refer document

BOQ Items

NAME OF WORK : PROVISION OF NEW SUBSTATION FOR SHIFTING OF ELECTRIC EQUIPMENT OUTSIDE ISSA LAB BLDG (BLDG NO P-147) AT METCALFE HOUSE UNDER GE I RnD DELHI
Sl. No. Item Description
1Excavation in trenches in soft/loose soil, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, for laying of cables, water pipe line etc not exceeding 10 Sqm on plan and not exceeding 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed.
2All as per item Ser No 1.00 above but exceeding 1.5m & not exceeding 3m in depth.
3All as per item Ser No 1.00 above but in hard/dense soil.
4Surface excavation not exceeding 30cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and directed.
5Returning, filling in, in trenchesincluding spreading leveling, watering and well ramming in layers not exceeding 25cm in soft/loose soil complete all as specified and directed.
6Removing excavated material exceeding 1.5 KM and not exceeding 5 KM and depositing where directed at a level not exceeding 1.5m above the starting point outside MoD land complete all as specified and directed.
7M&L treating the soil alongwith external perimeter of building @ 2.25 litres of emulsion complete all as specified and directed.
8Spreading and levelling in layers not exceeding 25cm thick in soft/loose complete all as specified and directed.
9M&L PCC 1:4:8 type D-2 (using 40mm graded mechanical crushed stone aggregate) as in foundation filling and mass concrete complete all as specified and directed.
10M&L PCC 1:3:6 type C-2 (using 40mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
11M&L for RCC M-25 design mix (using 20 mm graded stone aggregates) as in foundations, including rafts, footings, foundation beams plinth beams bases for columns, etc basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
12M&L RCC M-25 design mix (using 20 mm graded stone aggregates) as in columns, pillars, piers, posts and struts complete all as specified and directed.
13M&L RCC M-25 design mix (using 20 mm graded stone aggregates) as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed.
14M&L RCC M-25 design mix (using 20 mm graded stone aggregates) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
15M&L RCC M-25 design mix (using 20 mm graded stone aggregates) as in chajjas complete all as specified and directed.
16M&L mild steel TMT bar 10 mm dia and over cut to length, bent to shape required including cranking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
17All as per item Ser No 16.00 above but 6 to 8 mm.
18All as per item Ser No 16.00 above but 5 mm dia and over up to 8 mm dia as in stirrups, spacers and binders.
19Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work vertical or to batter complete all as specified and directed.
20Use and waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and directed.
21Use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc also splays between floors and beams complete all as specified and directed.
22Use and waste of form work to soffits of suspended slab such as roof slab, floor slab, landings and similar work not exceeding 20cm thick (horizontal or slopping) for fair finished surfaces complete all as specified and directed.
23Use and waste of form work to sides & soffits of plinth bands , lintel band, Shelves etc including, shelves etc complete all as specified and directed.
24Use and waste of form work to chajjas and similar work for fair finish surfaces complete all as specified and directed.
25Use and waste of formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs not exceeding 20cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exceeding 10cm but not exceeding 20cm wide complete all as specified and directed.
26M&L for brick work with sub class ‘B’ bricks, old size bricks, straight or curved on plan exceeding 6 mtr mean radius built in CM 1:6 complete all as specified and directed.
27M&L for brickwork with sub class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed.
28M&L for 15 mm thick plaster onbrick work or concrete surfaces in CM 1:4 mixed with WPC as per manufactures instruction finished even and smooth without using extra cement complete all as specified and directed.
29M&L for 15mm thick plaster in CM 1:6 on brick or concrete wall surfaces of any description finished even and smooth without using extra cement complete all as specified and directed.
30M&L for 5mm thick plaster in CM 1:3 as in soffits of slabs complete all as specified and directed.
31Supply only integral water proofing compound complete all as specified and directed.
32M&L for treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface CHLOROPYRIPHOS 20 EC or LINDANE 20 EC complete all as specified and directed.
33M&L for 18-20mm thick machine cut kota stone slab (table rubbed and polished) as in flooring set and jointed with grey cement slurry mixed with pigment to match the shade of slab including, cutting, rubbing, grinding and mirror polishing and double moulding laid over and including 15 mm thick screed bed or bedding layer in CM 1:6 complete all as specified and directed.
34M&L machine cut kota stone slab 18-20mm thick as in skirting, risers of steps set and jointed with grey cement slurry mixed with pigment to match the shade of slab including cutting, rubbing, grindingand mirror polishing and double moulding laid over and including 10 mm thick rendering in CM 1:6 complete all as specified and directed.
35M&L for 1st quality non skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc set & jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile laid over 15mm thick screedbed and bedding layer of CM 1:6 complete all as specified and directed.
36M&L for 1st quality Glazed coloured ceramic tiles in vertical surface/dado etc of size 450X 300X 7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick rendering in CM 1:4 complete all as specified and directed.
37M&L for 18 to 20mm thick granite stone slab as in shelves over cooking platform, machine cut bedded and jointed with grey cementslurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing laid over 15 mm thick sereed bed in CM 1:6 complete all as specified and directed.
38M&L for 18 to 20mm thick granite stone slab on vertical surfaces such as skirting/dado etc set and jointed with grey cementslurry and pointed with white cement with admixture of pigment to match the shade of granite stone and beveling half round edges of stones fixed over and including 10 mm thick rendering in CM 1:4 complete all as specified and directed.
39M&L for prepration of newly plastered surface ceiling surface walls and applying three coats of lime wash complete all as specified and directed.
40M&L for preparation of new plastered surface of wall and applying two coats of acrylic smooth exterior paint with silicone additives, applied @ 1.43 ltr/10 Sqm over a coat of priming coat of exterior primer applied @ 2.20 kg/10 Sqm complete all as specified and directed.
41M&L for preparation of newly plastered surface of wall and applying two coat of oil emulsion distemper over 2mm thick wall care putty in two layers (each layer minimum 1mmthick) complete all as specified and directed.
42M&L for aluminum window double shutter glazed & gauged with galvanized mild steel wire cloth nominal dia of wire 0.56 mm and average width of aperture 1.18 mm and including aluminium grill, size of frame 150 mm x 44.5 mm of 16 gauge aluminium section with 50 micron anodizing size of shutter top, bottom and side rail 75mm x 44.5 mm x 18 gauge & 5.50 mm thick reflector sole sheet glass to be fixed in glazed portion and stainless steel hooks & eye to be provided as stay of shutter etc complete including necessary jointing cleats, glazing clips, rubber packing , anodized aluminium snap beading, screws, anodized aluminium fittings such as peg stay 150 mm long (01 No for each leaf), stainless steel hinges type B-21, 100 mm long (02 Nos for each leaf), Aluminium Handle 75mm long D type (01 No for each leaf ) and 100 mm aluminium tower bolt (2 Nos in each leaf ) complete all as specified and directed.
43M&L for treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area CHLOROPYRIPHOS 20 EC or LINDANE 20 EC complete all as specified and directed.
44M&L for 75mm thick PCC 1:3:6 type C-1 (using 20 mm graded stone aggregate) as in plinth protection/path laid in bays including finishing the concrete surface even and smooth with out using extra cement complete all as specified and directed. Note: The unit rate quoted shall be deemed to include for providing the concrete in alternate bays not exceeding 3 mtr long with 12 mm wide and 50 mm deep joint between the bays which shall be filled with mastic filling with hot bitumen 85/25 and 1:2 mix by volume.
45M&L for hard core of broken stone gauge not exceeding 63mm deposited and leveled in layer not exceeding 15 cm thick watered and rammed to a true surface complete all as specified and directed.
46S&F Fancy type teak wood finish curtain rod MS chromium plated with fancy type bracket complete all as specified and directed.
47S&F 32 mm dia 3-layer PP-R Polypropylene random copolymer) pipes SDR 7.4 & SDR 11 UV stablised and antimicrobial welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded Polypropylene random fittings fixed complete to walls, ceilings or in floors etc complete all as specified and directed. Note: Cutting chases for concealing the pipes & fittings etc wherever required andmaking good, disturbed surface in CM 1:3 shall be included in the quoted rate.
48All as per item Ser No 47.00 above but 20 mm dia.
49S&F 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed.
50S&F 110 mm bore PVC (SWR) bends any radius complete all as specified and directed.
51S&F 100 mm bore PVC P or S trap dia complete all as specified and directed.
52S&F 75 mm bore for PVC (SWR) pipe in any length with rubber ring joints fixed to walls as in vent pipe including PVC cowl complete all as specified and directed.
53S&F 15mm bore brass chromium plated fancy type concealed stop cock reduced body etc complete all as specified and directed.
54S&F grating of size 125 mm CP for out let of water etc complete all as specified and directed.
55S&F liquid soap container of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats (minimum weight 105 grams) complete all as specified and directed.
56S&F Stainless steeltowel Rail of size 600 mm with lower hanger fixed to wallcomplete all as specified and directed.
57S&FWC Orissa pattern size 580 x 440 mm of vitreous china (white) fixed with all including accessories including integral footrestetc complete all as specified and directed.
58S&F PVC low levelflushing cistern syphonic action type 10 litres capacity with inlet ball valve, float and handle including PVC flush pipe 32 mm dia with bend and a pair of mild steel angle iron brackets of suitable size including making necessary connections to water supply pipe line and WC complete all as specified and directed.
59S&F brass chromium plated 15mm bore pillar taps fancy type, with capasten heads, scewed down high pressure, with or without lettered "HOT" or "COLD" with long screwed shanks and fly nut, screwed for iron pipes and fixed complete all as specified and directed.
60S&Fbib taps 15 mm bore chromium plated, long bodyfancy type, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
61S&F vitreous china wash basin white flat back size 580x 450mm excluding pillar tap but including 32mm dia CP waste fitting and PVC waste pipe 610 mm long and brackets complete all as specified and directed.
62S&F bevelled edge looking mirror 5 mm thick of selected quality glass mounted on 6mm thick building board or commercial plywood and fixed to wooden plug with chromium plated brass screw and cup washer including first class hard wood teak framing 40 mm x 8 mm alround, made to shape and french polished complete all as specified and directed.
63S&F stop valves/angle valves cast copper alloy chromium plate concealed fancy type screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipe 15mm dia complete all as specified and directed.
64S&F PVC connections 15mm dia, 450 mm long with PTMT nut on both ends and washers complete all as specified and directed.
65S&F PTMT ball valve high pressure with polylethylene float ball and fly nut screwed for iron pipe and fixed, 20 mm bore complete all as specified and directed.
66S&F stainless steel toilet paper holder complete all as specified and directed.
67S&F brass Chromium Plated soap dish fixed to wall with CP brass screws etc complete all as specified and directed.
68S&F brass Overhead Shower 200x200mm Square Shape Single Flow (Body & Face Plate Brass with Chrome Plated with grey face plate) with cleaning system suitable for 15mm bore GI pipe complete all as specified and directed.
69S&F 1000 litres capacity rotational moulded polyethyelene water storage tank three layered (Cylindrical vertical with closed top) hoisted and fixed in position of fixed with and incliuding PVC tank cover,PVC tank nipple (Minimum weight 20mm-45gms) and necessary connections complete all as specified and directed.
70S&FUPVC Floor/Nahani Trap of self cleaning design with CP jally complete in all respects of size 110x 90mm complete all as specified and directed.
71S&F UPVC Gully traps (self cleansing design) with CP jally complete in all respects of size 160x 110mm Single / double size as per sitecomplete all as specified and directed.
72S&FPVC soap tray, 350X100X60mm, fixed to wall with plugs and chromium plated screws complete all as specified and directed.
73S&F sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated brackets, guard and railing 60cm long complete all as specified and directed.
74S&F 125mm to 175mm hat pegs of aluminium, solid body fixed with screws complete all as specified and directed.
75S&F 15 mm dia of bore, Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe,complete all as specified and directed.
76All as per item Ser No 75.00 above but for 20 mm.
77S&F solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube as specification and drawing in SSR complete all as specified and directed.
78S&F Factory made solid panel PVCdoor shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing shown in SSR complete all as specified and directed.
79M&L for PCC 1:3:6 type C-1 (20 mm graded stone aggregate) as in filling pressed steel frame or hold fast blocks complete all as specified and directed.
80S&F 200 mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and directed.
81S&F butt hinges, 100mm sizeextruded brass, with mild steel hinge pin, bright polished and fixed, type B-21 complete all as specified and directed.
82S&F 150mm aluminium anodised barrel tower bolts of extruded section complete all as specified and directed.
83S&F 250mm size aluminium alloy anodised sliding door bolt with hasp staple (bolt type) and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy complete all as specified and directed.
84M&L for applying one coat of synthetic enamel paint on old decorated steel surfaces exceeding 10 cm width or girth including preparation of surfaces, complete all as specified and directed.
85M&L Water proofing treatment over roof at any height consisting evenly applied primer coat @ 0.30 litre/ Sqm on surfaces, overlaps, joints etc and a layer of APP polymer 3 mm thick even membrane weight not less than 3.00 Kg/ Sqm duly sealed at over laps joints with flame (complete by torch application) all as per manufacturer"s instructions, over and including15 mm thick screed bed of CM 1:4 mixed with water proofing compound @ 2% by weight of cement, complete all as specified and directed. Note: (i)Water proofing compound shall be measured and paid separately. (ii)Application of polymeric membrane shall be by torch application. (iii) The over lap shall be minimum 100 mm on transverse direction and 75 mm inlongitudinal direction. (iv)Primer shall be applied after preparing & cleaning of fully dried cement plastered surface. (v) Applying a coat of solar reflective bituminous aluminium paint @ 0.15 Kg per Sqm over the membrane complete.
86M&L for PCC 1:2:4 type B-0, (using 12.5 mm graded mechanically crushed stone aggregates) as in roof kerbs, benching and the like, etc complete all as specified and directed.
87M&L 75mm thick PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregates) as in sub base, Floors, Paving,finished even and fair complete all as specified and directed.
88M&L 25mm thick PCC 1:2:4 type B-1 (using 20mm graded aggregate) as in flooring, finished even & fair complete all as specified and directed.
89S&F rolling shutters 1.25mm thick laths, without ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer, erected in position as indicated, push pull or manual type complete all as specified and directed.
90S&F Safety lever locks mild steel with 4 levers for rolling sutter complete all as specified and directed.
91S&F ball bearing for rolling shutter complete all as specified and directed.
92S&F Collapsible steel gates, top hung, consisting for channel pickets, pivoted flat bars, top and bottom runners, brass handles etc erected in position and securing runners with holdfasts and brackets complete all as specified and directed.
93M&L for preparing new steel surfaces over 10 cm width or girth & applying two coats of synthetic enamel paint over a coat or red oxide primer complete all as specified and directed.
94Demolition of cement concrete in ground floor and paving not exceeding 15 cm below or above ground level etc complete all as specified and directed.
95M&L for pre-polished coloured chequered cement concrete tiles 30cm X 30cm X 20-22mm thick, with white cement and pigment, set, jointed and pointed in neat cement slurry in floors over and including 20mm thick screed bed in CM 1:6 complete all as specified and directed.
96M&L for 60 mm thick factory made machine pressed precast concrete interlocking paver block M-35 grade with Grey cement and pigment, any shape and size complete all as specified and directed.
97M&L for sand filling 40 mm thick under interlocking tiles watering and consolidation complete all as specified and directed.
98Demolition of brick work built in cement mortar or cement lime mortar including cleaning and stacking of serviceable bricks complete all as specified and directed.
99Taking down cement plaster/ gritplaster on brick walls, raking out joints hacking for key, scrubbing down with water etc complete all as specified and directed.
100M&L rendering 15 mm thick plaster in CM 1:4 on brick walls or concrete surface, surface finished even and smooth without using extra cement complete all as specified and directed.
101M&L for preparation of newly plastered outer wall surfaces and applying two coats of cement base paint complete all as specified and directed.
102M&L PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in copings, kneelers, apex stones, bed plates, kerbs, water troughs,and the like including weathering, slightly rounded or chamfered angles and throating incl use of formwork (straight or curved) complete all as specified and directed.
103M&L PCC 1:3:6 type C-2 (40mm graded stone aggregate) as in surface channel & drain complete all as specified and directed.
104M&L extra for forming fair finished drains or channels30cm inner girth in cement concrete using extra cement including forms, moulds, mitred/stopped ends etc complete all as specified and directed.
105M&L precast RCC 1:2:4 type B1 as in landings, manhole cover, cover slab, chhajja etc and similar articles with plain faces set in CM 1:6 including formwork weathring slightly rounded or chamfered angles and throating complete all as specified and directed.
106M&L PCC 1:3:6, type C-2 (using 40 mm graded stone aggregate) as in concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid and tested for 150 mm dia SWG/PVC pipe complete all as specified and directed.
107Providing, fixing, jointing and testing in position of ISI marked UV stablized UPVC pipe size 150mmfor soil, waste, and vent, type-B as per IS-13592 suitable for rubber ring joints, including all necessary specials and fittings (Confirming to IS-4735) i.e. bends, tees,junctions (with or without doors), reducers, WC connectors, couplers, cowels, clamps, rubber rings, clean outs etc, fixing at/in trenches complete all as specified and directed.
108Cutting in to existing manholes for connecting new drains, making good to pipe & rendering cutting out existing benching for and forming branch channel in cement concrete1:2:4 type B-1 smooth finished and reforming benching as required for 150 mm bore drain pipe complete all as specified and directed.
109Taking proper shutdown disconnection and dismantling and taking down existing old incoming busbar trunking system from existing transformer and LT panel care fully and removing from site complete all as specified and directed.
110Disconnecting Existing Serviceable 630 KVA Transformer carefuly from incoming & outgoing connection ( HT/LT Cables, Earthing connections, fixtures etc), and taking out from foundation. The same will be shifted to new location with crane upto 500 mtr distance and be fixed on the new location including testing and commissioning of same with incomer and outgoing LT & HT cable connections, earthing and including synthetic enamel fire proof paint two coats over existing painting etc complete all as specified and directed.
111Disconnecting Existing Serviceable VCB carefuly including incoming & outgoing connection from VCB (HT Cables, Earthing connections, fixtures etc) and reconnection, servicing, caliberation etc completeincluding testing and commissioning of same with incomer, outgoing HT cable connections, earthing etc complete all as specified and directed.
112Taking down old unserviceable LT/HT cable and removing from site complete all as specified and directed.
113Supply & laying or fixing on wall or passing through pipe, in trenches XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) with aluminium conductor 11000 volts grade sheathing of PVC tape with galvanised steel wire or tape and over all PVS sheathed 3 core cross-sectional area 120 Sqmm complete all as specified and directed.
114Supply & layingand testing cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cable (Heavy duty) 1100 volts gradewithstranded aluminium conductor 400 Sqmm 3.5 core complete all as specified and directed.
115Supply & fix cable jointing kit for 11KV (Earthed) grade cable for indoor type end Termination Jointing Kit, Cold shrink type joint complete with jointing material and accesories suitable for 3 core XPLE armouredaluminium cable of size 120 Sqmm complete all as specified and directed.
116S&F LT Danger Notice Plate of size 20x15 cm and 1.6 mm thick, mild steel sheet, vitreous enameled white with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamp, bolts and nuts of approved sizefor LT complete all as specified and directed.
117S&F HT Danger Notice Plate of size 25x20 cm and 1.6 mm thick, mild steel sheet, vitreous enamelled white with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamp, bolts and nuts of approved sizefor HT complete all as specified and directed.
118Supply and fix cable route indicator Cast iron with angle iron 40x40mm stand to be fixed and including PCC and earth work complete all as specified and directed.
119S&F mild steel sheet upto 6mm thick for cable pit duct/trench cover with chequered plate FE-410W (Gde E-250) including handles and angle iron frame work complete all as specified and directed.
120M&L synthetic rubber insulated mats for sub station of size 2Mtr x 1 Mtr x 2.5 mm thick for voltage upto 11 KV as per IS-15652-2006 for electrical shock safety complete all as specified and directed.
121Material and Labour for earthing complete with iron earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not less than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same.GI plate connected with galvanised iron strip of 32x6 mmby means of Copper nuts, bolts and washers.Strip laid in 40mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) with following complete all as specified and shown in electrical plate No 3 of SSR Part-I & testing on completion :- (a)GI strip of size 32mm x 6mm. (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit.(GI Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits) (c)Excavation & earthwork in any type of soil PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 50mm thick 1:2:4 type B1 reinforced with 8mm dia mild steel bar 75mm centre to centre with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover.
122M&L Earth continuity conductor or main earthing strip galvanised iron, size 32x6 mm fixed on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop eathing etc as required complete all as specified and directed.
123Supply & laying in trenches/fixing on wall or passing through pipe/trenches and testing 50 Sqmm 3.5 corecable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cable (Heavy duty) 1100 volts gradewithstranded aluminium conductor complete all as specified and directed.
124Supply & laying clean dry fine sand for cushioning of underground cable laid in trenches/duct complete all as specified and directed Note : Punned thickness shall be measured and paid sand shall be laid 8cm below & 15cm above the cable.
125Supplying and laying unreinforced precast concrete cable cover class LV, type I, flat of size 250x150x40mm for protection of cable in trench to be laid width wise complete all as specified and directed.
126Supplying and laying unreinforced precast concrete cable cover class HV, type I, flat of size 300x180x40mm for protection of cable in trench to be laid width wise complete all as specified and directed.
127Supply and laying in trench 100 mm dia GI pipe medium grade for protection of cable in road crossing, pipe with all fittings etc complete all as specified and directed.
128Supply and laying in trench 50 mm dia GI pipe medium grade for protection of cable in road crossing, pipe with all fittings etc complete all as specified and directed.
129Supply & laying in trench/fixed with wall/laid in floors or any other indicated situations 25 mm dia GI Pipe medium grade complete with all fittings complete all as specified and directed.
130Supplying and laying in trenches/fixing on wall/laid in floor, 25 mm OD CPVC pipes SDR 11 & plain CPVC SDR 11 fittings complete all as specified and directed.
131S&F 25 mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
132Cutting existing steel tubing for alterations or additions (Each cut measured) for 40- 50 mm dia GI Pipe complete all as specified and directed.
133M&L for point wiring with two run of PVC insulated unsheathed FRLSH single core multi stranded copper conductor and one run of PVC insulated FRLSH copper conductor cable as earth continuity wire for one light/fan/exhaust fan/call bell point wiring of any length as per site requirment passing through and including rigid PVC concealed conduit of suitable size but not less that 20 mm dia to be terminated in concealed GI sunken box of size suitable for modular switches and sockets etc for concealed wiring complete and making good the disturbed surfaces of wall, floor/ ceiling complete all as specified and directed.
134All as per item Ser No 133.00 above but wiring for 5 Amps socket outlet point on the same board with other switches.
135All as per item Ser No 133.00 above but wiring for 5 Amps switch socket outlet point on the Independent board.
136All as per item Ser No 133.00 above but wiring for one 15/16 Amps power point with 4.0 Sqmm single core copper conductor wire and 4.0 Sqmm wire for earth continuity on independent board.
137S&F modular switch single pole one way6 Amps 1 module complete all as specified and directed.
138S&F modular switch single pole one way 16 Amps 1 module complete all as specified and directed
139Supply and fix modular socket 6 amp-2/3 pin combined 2module complete all as specified and directed.
140M&Lof modularsocket 6 /16 Amp -2/3 pin combined 2 module complete all as specified and directed.
141S&F SPN DB 12 ways with 200 amps rated busbar 230 volt double door complete all as specified and directed.
142S&F MCB SP, C- curve, 230 volt6 -32 amp 10KA complete all as specified and directed.
143S&F MCB SPN 415 volt 40 amp 10Ka `C" curve complete all as specified and directed.
144M&L for wiring for circuit/submain wiring alongwith earth wire of FRLS PVC insulated copper conductor,single core cableof size 2X6 sq mm + 1X6.0 Sq mm earth wire in and including 25mm concealed PVC conduit and lugs/thimble etc complete all as specified and directed.
145S&Fwall mounted LED batten with aluminium housing & integral electronic driver having 10W LED 6500K mirror lightincluding making electric connection from ceiling rose or connector to light complete all as specified and directed.
146S&F wall mounted LED batten with aluminium housing & integral electronic driver having 20W LED 6500Kincluding making electric connection from ceiling rose or connector to light complete all as specified and directed.
147S&F Ceiling rose, 3 Terminal/PVC/ polycarbonate, isolated body complete all as specified and directed.
148S&F exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers complete all as specified and directed.
149All as per item Ser No 148.00 above but 380 mm sweep exhaust fan.
150S&F ceiling fans, complete with three blade, down rod, accessories 230V, 1200mm sweep, with Squirrel cage induction motor complete all as specified and directed.
151S&F LED street light fitting 60 watt 230 volts AC outdoor type with high pressure die cast aluminium housing and heat resistant cover with driver, lamp, bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP65/66 protection complete all as specified and directed.
152S&F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc complete all as specified and directed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail