Military Engineer Services-MES has published Tender For Repair Maintenance To Roof Treatment In P 01 P 6F P23 P-20 And P-50 Repair Maintenance Of Ext Elect Supply Of Oh Line Ug Cable Panel Board And Connected Works Under Ge I Gos. Submission Date for this Tender is 16-02-2023. Overhead Line Tenders in gopalpur Odisha. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Taking down existing water proofing membrane and cleaning roof, 15mm thick plastered surface etc preparing the surface to receive plaster by brushing whith wire brush and fanning the surface to remove all loose dirt etc and brushing neat cement slurry @ 3.00 Kg/Sqm including 15 mm thick plastered in cement morter 1:4 withwater proofing comound complete all as specified and as directed. |
2 | M&L for water proofing treatment for roof slabs by applying bitumen primer @ 0.3 ltr/sqm then applying hot blown bitumen 85/25 @ 1.20kg/sqm and laying 3 mm thickwater proofing membrance modified with glass mat reinforcement weight not less than 3 kg /sqm with overlap of 100 mm and end lap 150 mmand finally applying aluminium based pain on top complete all as specified and as directed. |
3 | Demolition of brick work built in cement mortar including all quoins, pillars, arches etc complete all as specified and directed. |
4 | M&L Brick work with fly ash bricks straight or curved on plan exc 6m mean radius built in CM 1:6 Complete all as specified and directed. |
5 | Taking down cement plaster of any description including raking outjoints, hackisng for key, scrubbing down with water etc complete all as specified and as directed. |
6 | M&L for rendering plaster 15 mm thick in cement mortar 1:4 on fair faces of brick work or concrete surface of wall and finiceshed even and smooth without using extra cement complete all as specified and as directed. |
7 | Supply only integral water proofing compound complete all as specified and as directed. |
8 | M&L for preparaion of newly plastered or unplaseteredsurfaces and apply finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)® walls complete all as specified and as directed. |
9 | M&L complete removal existing treatmentincl cornices pillaster etc and applying two coat of white wash on ceiling complete all as specified and as directed. |
10 | M&L preparing newlyplastered surface of walls and applying two coats of cement paint on wall complete all as specified and as directed. |
11 | Taking up or down steel water tubing and connections of 15 mm bore |
12 | All as per item No 11 above but 20 mm bore |
13 | Supply and laying CPVC pipesSDR 11 & Plain CPVC 11 fitting on walls/ceiling or laying in floor complete all as specified of 16 mm outer dia |
14 | All as per item No 13 above but 20 mm outer dia |
15 | S&F CPVC Brass Elbow16 mm outer dia |
16 | All as per item No 15 above but 20 mm outer dia |
17 | S&F CPVC Brass Elbow (3/4 x1/2) 20 mm outer dia |
18 | S&F CPVC Brass Tee 16 mm outer dia |
19 | All as per item No 18 above but 20 mm outer dia |
20 | S&F CPVC Male Brass Threaded Adaptor (MTA/MBTA) 16 mm outer dia |
21 | All as per item No 20 above but 20 mm outer dia |
22 | S&F CPVC Female Brass Threaded Adaptor (FTA/FBTA) 16 mm outer dia |
23 | All as per item No 22 above but 20 mm outer dia |
24 | S&F CPVC Tank adaptor 20 mm outer dia |
25 | S&F CPVC Union 16 mm outer dia |
26 | All as per item No 25 above but 20 mm outer dia |
27 | S&F in repair ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe of 20 mm bore (minimum weight210 gms), fixed complete all as specified and as directed. |
28 | S&F in repairs gun metal globe or gate valve with iron wheel screwed both ends for iron pipe of 20 mm dia complete all as specified and as directed. |
29 | S&F in repair 110mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls complete all as specified and as directed. |
30 | S&F in repair 110mm bore PVC (SWR) bends any radius complete all as specified and as directed. |
31 | Dismantling PVC water tanks exc 1000 ltr but n. exc 2000 ltr capacity and removing to store complete all as specified and as directed. |
32 | S&F 1000 ltr capacity Rotational moulded polyethylene water storage tanks (cylin-drical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and as directed. |
33 | Excavation in trenches in hard/dense soil n.exc 1.5 mtr wide and n.exc 1.5 mtr depth and getting out pole foundation/cable trench complete all as specified and directed. |
34 | All as per item No 33 above, but in hard /dense soil. |
35 | Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm thick complete all as specified and directed. |
36 | Removing surplus excavated material not exc 50 mtrs and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed. |
37 | Supply and providing sand cushioning with dry clean sand 8 cm below cable and 15 cm above the cable complete all as specified and directed. Note : Punned thickness shall be measured for the purpose of payments. |
38 | Supply and laying Fly ash bricksin trenches for cable protection with length of brick perpendicular to length of cable complete all as specified and directed. |
39 | Material and labour for filling the road / hard standings cut for laying cable with PCC 1:2:4, type B2, using 40 mm graded stone aggregate and finishing the surface even and smooth without using extra cement complete all as specified and as directed. |
40 | Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured electric power cables heavy duty 1100 volts grade, with stranded aluminium conductor with all fixing & connecting accessories such as aluminium cable lugs, cable gland, nut, bolts, washer etc Including taking out existing unserviceable cable of 3.5 core x 70 Sqmm sizes complete all as specified and as directed. |
41 | All as per item No 40 above but 3.5 core x 50 Sqmm |
42 | All as per item No 40 above but 3.5 core x 35 Sqmm |
43 | All as per item No 40 above but 3.5 core x 25 Sqmm |
44 | All as per item No 40 above but 4 core x 16 Sqmm |
45 | All as per item No 40 above but 4 core x 10 Sqmm |
46 | S & fix LT Cable joining kitheat shrinkabale complete with jointing materials suitable for LT Armoured cable 4 core of size 10 to 16 Sqmm complete all as specified and as directed. |
47 | S & fix LT Cable joining kitheat shrinkabale complete with jointing materials suitable for LT Armoured cable 3.5 core of size 25 to 50 Sqmmcomplete all as specified and as directed. |
48 | S & fix LT Cable joining kitheat shrinkabale complete with jointing materials suitable for LT Armoured cable 3.5 core of size 70 to 150 Sqmm complete all as specified and as directed. |
49 | M & L GI tubing light grade with all fitting(ISI marked) for protection of cable fixed to pole/wall / laid under floor or road including necessary joints and clamps complete all as specified and directed for 50 mm boresizes. |
50 | All as per item No above but 40 mm bore |
51 | Boring of holes horizontally for laying of pipe not less than 100 mm dia (min depth 0.90 mtr to 0.120mtr from top level) under road, hardstanding by trench less technology for passing cable through pipe with mechanical/hydraulic/compresser pressure pump machine system throughly so the surface of roadcan not be disturbed or cracked all as specified and directed. |
52 | M & L in repair for installation, commissioningand testing factory made CPRI approved out doorcubical type Panel Box totally enclosed over all size not less than 1500 x1000x.600 mm (LXBXH) fabricated with3.15mm thickCRCA sheet (Heavy duty) over a frame of 45x45x6 mm angle iron and mounted onplatform all around and dust & vermin proof, IP-65 protection,back side openable,fixed with nuts & bolts and front side openable withhinged shutterand locking arrangement by operate alen key individualsforMCCBs and over all front panel double door shutterwith powder coated finishedboth internallyand externallysuitable for 415 V,AC, 50 HZ, 3 Phase, 4 wire system by means of copper bus bar of size 50 x 5mm (Main) duly wrapped with coloured insulating tape/ sleevesmounted on porcelain insulators with provision of fixing MCCBs necessary inter connections with copper strips of size30x5mm duly wrapped with coloured insulating tape/ sleevesmounted on porcelain insulators andproviding following equipmentsincludingconnection with all incoming/outgoingcables ofdifferent size duly crimping with suitable size copper lugs complete incliding taking out old unsv Note : Drawing shall be got approved by Engr-in-charge before manufacturing of the LT panel. INCOMING: (a)Moulded case circuit breakers(AC 415) MCCB current rating 250 Amp-01 Nos,4 pole, breaking capacity Icu at 415 Volt, 36 KA , 50Hz with extended terminals adjustable microprocessor release industrialtype, adjustable thermal ( 40% - 100%) & adjustable magetic (6-10 times)Make- Havells/C&S /Legrand. OUTGOING:- (a) Supply and fix Thermal Magnetic release,MCCB 125 Amps 415 Volts=01 nos4 pole 25 KA, Ics=100% Icu, adjustable overload 80-100% and adjustable short circuit 5-10In complete with all required items.Make C&S / L&T/Havells.(b) Supply and fix Thermal Magnetic release,MCCB 40 Amps 415 Volts=05 nos4 pole 16 KA, Ics=100% Icu, adjustable overload 80-100% and adjustable short circuit 5-10In complete with all required items.Make C&S / L&T/Havells. (c) 1 No.Multifunctional Digital Voltmeter 0-500Volt with selector switch(d) 1 No. Multifunctional Digital Ampere meter 0-250 A with selector switch with CT"s. (e)LEDPhase (RYB) indicator lamp -01 Set (Set of three) |
53 | M & L in repair for installation, commissioningand testing factory made CPRI approved out doorcubical type feeder piller boxtotally enclosed over all size not less than 750x600x750mm (LXBXH) fabricated with3.15mm thickCRCA sheet (Heavy duty) over a frame of 40 x 40 x 6mm angle iron and mounted onplatform all around and dust & vermin proof, IP-65 protection,back side openable,fixed with nuts & bolts and front side openable withhinged shutterand locking arrangement by operate alen key individualsforMCCBs and over all front panel double door shutterwith powder coated finishedboth internallyand externallysuitable for 415 V,AC, 50 HZ, 3 Phase, 4 wire system by means of copper bus bar of size 50 x 5mm (Main) duly wrapped with coloured insulating tape/ sleevesmounted on porcelain insulators with provision of fixing MCCBs necessary inter connections with copper strips of size30x5mm duly wrapped with coloured insulating tape/ sleevesmounted on porcelain insulators andproviding following equipmentsincludingconnection with all in coming/outgoingcables ofdifferent size duly crimping with suitable size copper lugs complete including taking out old unsv Note : Drawing shall be got approved by Engr-in-charge before manufacturing of the LT panel. INCOMING: Supply and fix on load Change over switch 63 Amp, 4 pole in sheet metal enclosure complete all as specified and directed. HPL CatNo COS4FP63 or equivalent in Havells/C&S/L&T. OUTGOING:- (a) Supply and fix Thermal Magnetic release,MCCB 63 Amps 415 Volts,4 pole 25 KA, Ics=100% Icu, adjustable overload 80-100% and adjustable short circuit 5-10In complete with all required fitting items . Make L&T/Havells/C&S. (b) Refixing ,connecting of existing electric meter all as specified and directed. (c) 1 No. Digital Voltmeter 0-500Volt with selector switch . (d) 1 No. Digital Ampere meter 0-100 A with selector switch and CT"s. (e) LEDPhase indicator lamp -01 Set (Set of three) |
54 | Supply and fix Thermal Magnetic release,MCCB 400 Amps 415 Volts,4 pole 36 KA, Ics=100% Icu, adjustable overload 80-100% and adjustable short circuit 5-10In complete with all required fitting items Including taking down old unserviceable Mccb"s complete all as specified and directed. |
55 | Supply and fix Thermal Magnetic release,MCCB 250 Amps 415 Volts,4 pole 36 KA, Ics=100% Icu, adjustable overload 80-100% and adjustable short circuit 5-10In complete with all required fitting items Including taking down old unserviceable Mccb"s complete all as specified and directed. |
56 | Supply and fix Thermal Magnetic release,MCCB 160 Amps 415 Volts,4 pole 25 KA, Ics=100% Icu, adjustable overload 80-100% and adjustable short circuit 5-10In complete with all required fittings items Including Taking down old unservicable Mccb"s complete all as specified and directed. |
57 | Supply and fix Thermal Magnetic release,MCCB 125 Amps 415 Volts,4 pole 25 KA, Ics=100% Icu, adjustable overload 80-100% and adjustable short circuit 5-10In complete with all required fittings items Including Taking down old unservicable Mccb"s complete all as specified and directed. |
58 | Supply and fix Thermal Magnetic release,MCCB 100 Amps/80 Amps/63 Amps 415 Volts,4 pole 25 KA, Ics=100% Icu, adjustable overload 80-100% and adjustable short circuit 5-10In complete with all required items Including Taking down old unservicable Mccb"s complete all as specified and directed. |
59 | Re-stretching of ACSR conductor and earth wire of any size and type on LT poles including disconnection and re-binding with insulators with suitable size of binding wire after re-stretching, connecting jumpers, adjusting line dividers etc complete all as specified and directed. |
60 | Supply and fixing for pin type procelain, vitreous, white, brown or green insulator ,including galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut,100mm height, 65mm dia for working pressure 1100 volts,including taking down old insulators of any type , shape and size and removing from site complete all as specified and directed. |
61 | Taking down the burnt unserviceable timer box and supply and fix timelite distribution board 40A, 3 pole, 230V with analog timer switch complete all as specified and directed. |
62 | Painting to existing steel tubular LT poles , 9m long including cross arms, channels, angle iron support, bracings, clamps etc. with two coats of aluminium paint superior quality of approved make on surface expose to view and making 30 cm wide strips (total 5 Nos) with white and black paint alternatively on external surface above PCC benching including prepration of old painted surface by scraping complete all as specified and directed. |
63 | Supply and fixing 0f steel tubular swaged poles complete with cast iron base plate,finial tapper plug, bolts, nuts and screws as specified type 410 SP-64 (12.00 metres long), erected to truly vertical position including one coat of red oxide primer and two coats of aluminium paint and making 30cm wide strips 5 Nos with white and black paint alternately on external surface above PCC benching/ground level including making pole identification number andfigurewith synthetic enamel paint of Ist quality and painting with bitumenous paint internally and externally for portion embedded in PCC. , complete all as specified, including taking down oldpoles of any type and removing from site. |
64 | Supply & fix pole box of new technology made up ofThermoplastic Polycarbonate Pole box, install, testing and commissioning of Thermoplastic Polycarbonate Pole box which is shock, rust, dust,impact and waterproof, halogen and silicon free, UV resistance with internally embedded gasket high grade gasket made of polyurethane. The thermoplastic pole box suitable size with degree of protection IP 65, type tested, system voltage – 230V , 50Hz, Capacity with temperature resistance of -40°C to 120°C, with cable entry ,suitable size of Glands,all as specified andduly mounted on steel tubluar pole with suitable MS flat withbolts nuts and washers complete including supply fixing and making provision of theMCBSPN 30/32 Amp. |
65 | Supply and fixing80W new Generation ORION-ll LED HIGHBAY comes with high luminous efficacy upto >130 LPW,IP66 Protected,front toughened glass with discrete high lumen LEDlight,complete with connecting of suitable size of wire incl taking down old unsv complete all as specified and directed. |
66 | Taking down unserviceable aviation light fittings from OH tank, supply and fixing new 4W-6W LED aviation light without flashing fittings with and including clamps, bolts, nuts and service connections upto the junction box complete all as specified and directed. |
67 | Miled steel framed work such as grills,gratings,etc.with ends of bars shouldered and/or riveted or forged into spikes,framed guard bar,barred iron doors,ladder,framed balusters,ralling frame work etc and similar work conforming to Fe-290E-165 complete all as specified and directed. |
68 | Supply and fixing 3 core copper flexible cable FRLS 2.5 Sqmm size, 1100 volts grade complete all as specified and directed. |
69 | Supply and fixing LED flood light 200 watt Lumos II new generation LED with high luminous efficacy of 120 lm/w protected to IP-66 with front toughened glass complte in all respectwith GI tubing reqd in site, mounting bracket with its clamp incl two coats of synthetic enamel paint over a coat red oxide primer and with all accessories, incl connecting of with 2 run of suitable flexible aluminium/copper conductor of size 2.5 sq mm or fixed in appropriate size of PCC block made with PCC 1:3:6 with fixing arrangement suitable on site, testing & commissioning complete all as specified and directed. |
70 | Supply and fix in replacement of unsv LED Driver suitable for 60/72 watt LED street light fitting as existing complete all as specified and directed. |
71 | Trimming of trees and cutting of tree branches carefully upto 3 mtr clear distance from wire/cables/conductor/panel boards along LT over head electric line using all required safety equipment for each length of approx 40 metre long complete all as specified and directed. |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail