Tender For Repair Maintenance To Daikin Ac Plant (Vrv Units) Ac Plant Of Navjivani, Ac Plant At Katari Cadet Mess, Central Ac Plant With Lt Panels At Koutilya Auditorium And Cold Room Of Logistic Complex At Ina Ezhimala., Kannur-Kerala

Military Engineer Services-MES has published Tender For Repair Maintenance To Daikin Ac Plant (Vrv Units) Ac Plant Of Navjivani, Ac Plant At Katari Cadet Mess, Central Ac Plant With Lt Panels At Koutilya Auditorium And Cold Room Of Logistic Complex At Ina Ezhimala.. Submission Date for this Tender is 03-03-2023. Air Conditioner Tenders in Kannur Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

35971126
Corrigendum : Tender For Repair Maintenance To Daikin Ac Plant (Vrv Units) Ac Plant Of Navjivani, Ac Plant At Katari Cadet Mess, Central Ac Plant With Lt Panels At Koutilya Auditorium And Cold Room Of Logistic Complex At Ina Ezhimala.
Open Tender
Indian
Kerala
Kannur
03-03-2023

Tender Details

Repair Maintenance To Daikin Ac Plant ( Vrv Units ) Ac Plant Of Navjivani, Ac Plant At Katari Cadet Mess, Central Ac Plant With Lt Panels At Koutilya Auditorium And Cold Room Of Logistic Complex At Ina Ezhimala.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 10-Feb-2023 Corrigendum for Date Date 24-02-2023
2 13-Feb-2023 corrigendum for BOQ BOQ 24-02-2023
3 24-Feb-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 03-03-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 99000.0 /-
Tender Value
INR 49.50 Lakhs /-

BOQ Items

NAME OF WORK : REPAIR MAINTENANCE TO DAIKIN AC PLANT (VRV UNITS) AC PLANT OF NAVJIVANI, AC PLANT AT KATARI CADET MESS, CENTRAL AC PLANT WITH LT PANELS AT KOUTILYA AUDITORIUM AND COLD ROOM OF LOGISTIC COMPLEX AT INA EZHIMALA.
Sl. No. Item Description
1Comprehensive maintenance of variable Refrigerant Volume (VRV) outdoor unit 40 HP and associated indoor unit by OEM including routine preventive and immediate break down maintenance, repair and servicing once in three months as required for smooth and efficient functioning of the following units :-(A)LIST OF OUTDOOR UNIT :- (i) VRV Outdoor Unit 16 HP Sr. No. A000128 Located at Nalanda Building- 2(L/S), LVL-6Terrace - 01 No (ii) VRV Outdoor Unit 16 HP Sr. No. A000129 Located at Nalanda Building- 2(L/S), LVL-6 Terrace - 01 No (iii) VRV Outdoor Unit 8 HP Sr. No. A000266 Located at Nalanda Building- 2(L/S), LVL-6 Terrace - 01 No (B)LIST OF ASSOCIATED INDOOR UNIT :- (i) Decorative Under type ceiling indoor 2TR Sr. No. E004791 - 01 No (ii) Decorative Under type ceiling indoor 2TR Sr. No. E004795 - 01 No (iii) Decorative Under type ceiling indoor 2TR Sr. No. E004853, E004805 - 02 Nos (iv) Decorative Under type ceiling indoor 2TR Sr. No. E004794, E004743 - 02 Nos (v) Decorative Under type ceiling indoor 2TR Sr. No. E004602, E004716 - 02 Nos (vi) Decorative Under type ceiling indoor 2TR Sr. No. E004800 - 01 No (vii) Decorative Under type ceiling indoor 2TR Sr. No. E004715, E004803, E004846 - 03 Nos (viii) Decorative Under type ceiling indoor 2TR Sr. No. E004740, E004807, E004797 - 03 Nos Make : Daikin
2Comprehensive maintenance of variable Refrigerant Volume (VRV) outdoor unit 30 HP and associated indoor unit by OEM including routine preventive and immediate break down maintenance, repair and servicing once in three monthsas required for smooth and efficient functioning of the following units :- (A)LIST OF OUTDOOR UNITS :- (i) VRV Outdoor Unit 18 HP Sr. No. A001580 Located at Nalanda Building- 2 (L/S), LVL - 6Terrace - 01 No (ii) VRV Outdoor Unit 12 HP Sr. No. A000440 Located at Nalanda Building - 2 (L/S), LVL-6Terrace - 01 No (B)LIST OF ASSOCIATED INDOOR UNITS :- (i) Decorative Under type ceiling indoor unit 2TR Sr No. E004799, E004854, E004608 - 03 Nos (ii) Decorative Under type ceiling indoor unit 2TR Sr. No. E004739, E004786 - 02 Nos (iii) Decorative Under type ceiling indoor unit 3.2 TR Sr. No. E003032 - 01 No (iv) Decorative Under type ceiling indoor unit 2TR Sr. No. E004806 - 01 No (v) Decorative Under type ceiling indoor unit 2TR Sr. No. E004801, E004742 - 02 Nos (vi) Decorative Under type ceiling indoor unit 2TR Sr. No. E004744, E004798 - 02 Nos (vii) Decorative Under type ceiling indoor unit 2TR Sr. No. E004741 - 01 No Make : Daikin
3Comprehensive maintenance of variable Refrigerant Volume (VRV) outdoor unit 46 HP and associated indoor unit by OEM including routine preventive and immediate break down maintenance, repair and servicing once in three months as required for smooth and efficient functioning of the following units :- (A)LIST OF OUTDOOR UNITS :- (i) VRV Outdoor Unit 18HP, Sr No A001601 Located at Technical Wing LHS -27, Terrace - 01 No (ii) VRV Outdoor Unit 18HP, Sr.No A001608 Located at Technical Wing LHS -27, Terrace - 01 No (iii) VRV Outdoor Unit 10HP, Sr.No A000145 Located at Technical Wing LHS -27, Terrace - 01 No (B)LIST OF ASSOCIATED INDOOR UNITS :- (i) Ductable type VRV Indoor Unit 8TR, Sr.No. A006376, A006378, A006380 - 03 Nos (ii) Ductable type VRV Indoor Unit 6.4TR,Sr.No. A005495, A005549, A005550, A005566 - 04 Nos Make : Daikin
4Comprehensive maintenance of variable Refrigerant Volume (VRV) outdoor unit 46 HP and associated indoor unit by OEM including routine preventive and immediate break down maintenance, repair and servicing once in three months as required for smooth and efficient functioning of the following units :- (A)LIST OF OUTDOOR UNITS :- (i) VRV Outdoor Unit 18HP, Sr.No. A001606 Located at Technical Wing LHS -27, Terrace - 01 No (ii) VRV Outdoor Unit 18HP, Sr.No. A001605 Located at Technical Wing LHS -27, Terrace - 01 No (iii) VRV Outdoor Unit 10HP, Sr.No. A000384.Located at Technical Wing LHS -27, Terrace - 01 No (B)LIST OF ASSOCIATED INDOOR UNITS :- (i) Ductable type VRV Indoor Unit 6.4TR, Sr.No. A005492 - 01 No (ii) Ductable type VRV Indoor Unit 8TR, Sr.No. A006384 - 01 No (iii) Ductable type VRV Indoor Unit 4TR, Sr.No. A006037 - 01 No (iv) Ductable type VRV Indoor Unit 6.4TR, Sr.No. A005553 - 01 No (v) Ductable type VRV Indoor Unit 6.4TR, Sr.No. A005448, A005494 - 02 Nos (vi) Ductable type VRV Indoor Unit 6.4TR, Sr.No. A005491 - 01 No Make : Daikin
5Comprehensive maintenance of variable Refrigerant Volume (VRV) outdoor unit 40 HP and associated indoor unit by OEM including routine preventive and immediate break down maintenance, repair and servicing once in three months as required for smooth and efficient functioning of the following units :-(A)LIST OF OUTDOOR UNITS :-(i) VRV Outdoor Unit 16HP Sr.No.A000133 Located at Technical Wing RHS -13, Terrace - 01 No(ii) VRV Outdoor Unit 16HP, Sr.No.A000134 Located at Technical Wing RHS -13, Terrace - 01 No (iii) VRV Outdoor Unit 8HP, Sr.No.A000248 Located at Technical Wing RHS -13, Terrace - 01 No(B)LIST OF ASSOCIATED INDOOR UNITS :-(i) Ductable type VRV Indoor Unit 4TR, Sr.No. A006043, A006039, A006044 - 03 Nos(ii) Cassette type VRV Indoor Unit 2.5TR, Sr.No. C006512, C006511, C006508 - 03 Nos (iii) Decorative Under type ceiling indoor 2TR, Sr.No. E004802, E004848, E004804, E004789 - 04 Nos (iv) Decorative Under type ceiling indoor 2TR, Sr.No. E004847, E004792, E004793, E004836 - 04 NosMake : Daikin
6Comprehensive maintenance of variable Refrigerant Volume (VRV) outdoor unit 46 HP and associated indoor unit by OEM including routine preventive and immediate break down maintenance, repair and servicing once in three monthsas required for smooth and efficient functioning of the following units :-(A)LIST OF OUTDOOR UNITS :-(i) VRV Outdoor Unit 18HP Sr.No.A001604. Located at Technical Wing RHS-13, Terrace - 01 No (ii) VRV Outdoor Unit 18HP Sr.No.A001602 Located at Technical Wing RHS -13, Terrace -01 No(iii) VRV Outdoor Unit 10HP Sr.No.A002603 Located at Technical Wing RHS-13, Terrace -01 No(B)LIST OF ASSOCIATED INDOOR UNITS :-(i) Ductable type VRV Indoor Unit 8TR, Sr.No. A006379 - 01 No(ii) Ductable type VRV Indoor Unit 6.4TR, Sr.No. A005485, A005498, A005493 - 03 Nos(iii) Ductable type VRV Indoor Unit 6.4TR,Sr.No. A005500, A005497, A005499 - 03 Nos Make : Daikin
7Notefor Items Ser No 01 to 06 The Servicing/repair/replacement Work will be executed byDaikin (OEM)only and before accepting the contract, Contractor will be provide MoU (Memorandum of understanding) from Daikin. The contractor will be responsible for submitting a copy ofMoUto CWE Ezhimala before accepting the tender.
8Comprehensive maintenance of variable Refrigerant Volume (VRV) outdoor unit 36 HP (ones inthree months) and associated indoor unit by OEM including routine preventive and immediate break down maintenance, repair and servicing once in three months as required for smooth and efficient functioning of the unit during the maintenance period of 12 months as per the manufactures instructions. (A) List of Outdoor unit :- (i) VRV Outdoor Unit 36HP Sr.No.4YM00378 Located at Kattari mess RHS Terrace - 01 No (B) List of Associated indoor unit :- (i) Cassette type VRV Indoor Unit 4TR, Sr.No.54M00615,54M00613,54M00637,54M00614,54M00617,54M00634,54M00621,54M00612- 08 Nos Make: Mitsubishi.
9Comprehensive maintenance of variable Refrigerant Volume (VRV) outdoor unit 36 HP (once in three months) and associated indoor unit by OEM including routine preventive and immediate break down maintenance, repair and servicing once in three months as required for smooth and efficient functioning of the unit . (A) List of Outdoor unit :- (i) VRV Outdoor Unit 36HP Sr.No.4YM00360 Located at Kattari mess LHS Terrace - 01 No(B) List of Associated indoor unit :- (i) Cassette type VRV Indoor Unit 4TR, Sr.No.54M00618,54M00624,54M00620,54M00619,54M00636,54M00616,54M00622,54M00623- 08 Nos Make: Mitsubishi.
10Comprehensive maintenance of variable Refrigerant Volume (VRV) outdoor unit 20 HP (once in three months) and associated indoor unit by OEM including routine preventive and immediate break down maintenance, repair and servicing as required for smooth and efficient functioning of the unit (A) List of Outdoor unit :- (i) VRV Outdoor Unit 20HP Sr.No.4YM00364 Located at Kattari mess centre block Terrace - 01 No (B) List of Associated indoor unit :- (i) Cassette type VRV Indoor Unit 4TR, Sr.No.47M00243,47M00377,47M00380,56M00427- 04 Nos . Make:Mitsubishi.
11Note for Items Ser No 08 to 10 :- The Servicing/repair/replacement Work will be executed by Mitsubishi(OEM) only and before accepting the contract, Contractor will be provide MoU (Memorandum of understanding) from Mitsubishi . The contractor will be responsible for submittinga copy ofMoUto CWE Ezhimala before accepting the tender.
12Supply and fix in replacement of compressor 16 HP suitable for VRV unit complete including taking down of old compressor and re-filling of refrigerant (gas) as per site requirement including gas etc and testing on completion complete all as specified and as directed. Make as perOEM.
13Supply and fix in replacement of Inverter PCB board suitable for VRV unit complete ( for 36 HP outdoor unit) including taking down of old PCB and required connections and testing on completion etc complete all as specified and as directed. Make as perOEM.
14Supply and fix in replacement of Inverter PCB board suitable for VRV unit complete ( for 20 HP outdoor unit) including taking down of old PCB and required connections and testing on completion etc complete all as specified and as directed. Make as per OEM.
15Supply and fix in replacement of Inverter PCB board suitable for VRV unit complete ( for 30 HP outdoor unit) including taking down of old PCB and required connections and testing on completion etc complete all as specified and as directed. Make as perOEM.
16Supply and fix in replacement of Inverter PCB board suitable for VRV unit complete ( for 40 HP outdoor unit) including taking down of old PCB and required connections and testing on completion etc complete all as specified and as directed. Make as perOEM.
17Supply and fix in replacement of Inverter PCB board suitable for VRV unit complete ( for 46 HP outdoor unit) including taking down of old PCB and required connections and testing on completion etc complete all as specified and as directed. Make as perOEM.
18Supply and fix in replacement of Control PCB board suitable for VRV unit complete ( for 20 HP outdoor unit) including taking down of old PCB and required connections and testing on completion etc complete all as specified and as directed. Make as per OEM.
19Supply and fix in replacement of Control PCB board suitable for VRV unit complete ( for 30 HP outdoor unit) including taking down of old PCB and required connections and testing on completion etc complete all as specified and as directed. Make as perOEM.
20Supply and fix in replacement of Control PCB board suitable for VRV unit complete ( for 36 HP outdoor unit) including taking down of old PCB and required connections and testing on completion etc complete all as specified and as directed. Make as perOEM.
21Supply and fix in replacement of Control PCB board suitable for VRV unit complete ( for 40 HP outdoor unit) including taking down of old PCB and required connections and testing on completion etc complete all as specified and as directed. Make as perOEM.
22Supply and fix in replacement of Control PCB board suitable for VRV unit complete ( for 46 HP outdoor unit) including taking down of old PCB and required connections and testing on completion etc complete all as specified and as directed. Make as perOEM.
23Supply and fix in replacement of fan motor suitable for VRV unit complete including taking down of old un serviceable fan motor and required connections and testing on completion etc complete all as specified and as directed. Make as per OEM.
24Supply and fix high pressure switch suitable for VRV unit completeincluding taking down of old high pressure switch and required connections and testing on completion etc complete all as specified and as directed. Make as perOEM.
25Supply and fix discharge thermistor suitable for VRV unit completeincluding taking down of old high pressure switch and required connections and testing on completion etc complete all as specified and as directed.
26Supply and fix in replacement of indoor PCB board suitable for VRV unit complete including taking down of old PCB and required connections and testing on completion etc complete all as specified and as directed.
27Supply and fix low pressure switch suitable for VRV unit complete including taking down of old low pressure switch and required connections and testing on completion etc complete all as specified and as directed.
28Supply and fix in replacement indoor unit remote control suitable for VRV unit including testing complete all as specified and as directed.
29Comprehensive maintenance and servicing every quarterly (once in three months) for the following 24 TR Air cooled scroll chiller with microprocessor control AC plant including break down maintenance as and when required, repair/replacement of defective unserviceable minor spare parts like nuts, bolts, washers, grease etc during the maintenance period and necessary periodical maintenance/checking as per the Manufacturer"s instructions and as directed. Blue Star Model No XAC25-024M (Location : Navjivani Hospital) for the following:-
30Chiller 1 Sl No : 5467A E10
31Chiller 2 Sl No : 5467B E10
32Chiller 3 Sl No : 5467C E10
33Comprehensive maintenance and servicing every quarterly (once in three months) for the following Blue star walk in freezer 15000 BTU low temperature cold room with microprocessor control AC plant including break down maintenance as and when required, repair/replacement of defective unserviceable minor spare parts like nuts, bolts, washers, grease etc during the maintenance period and necessary periodical maintenance/checking as per the Manufacturer"s instructions and as directed. Model No Blue star (Location : Logistic Complex)for following Condensing unit M/C No :-
34Condensing unit M/C No 13F00084, Evaporation unit M/C No 13F00094
35Condensing unit M/C No 13F00074, Evaporation unit M/C No 13F00084
36Condensing unit M/C No 13F00070, Evaporation unit M/C No 13F00092
37Comprehensive maintenance and servicing every quarterly (once in three months) for the following Blue star walk in freezer 20000 BTU plus temperature cold room with microprocessor control AC plant including break down maintenance as and when required, repair/replacement of defective unserviceable minor spare parts like nuts, bolts, washers, grease etc during the maintenance periodand necessary periodical maintenance/checking as per the Manufacturer"s instructions and as directed. Model No Blue star (Location : Logistic Complex)for following Condensing unit M/C No :-
38Compressor sl No CD1006430479, Evaporation unit M/C No 13F00001
39Compressor sl No CB1006430503, Evaporation unit M/C No 13F00002
40Compressor sl No CC1006430508, Evaporation unit M/C No 13F00003
41Compressor sl No CC1006430634, Evaporation unit M/C No 13F00012
42All as per above but installed at somen mess with Compressor sl No CC1006430622 & Evaporation unit M/C No 13F00009 complete.
43Comprehensive maintenance and servicing every quarterly (once in three months) for the following Blue star two body mortuary cabinet complete with its accessories including break down maintenance as and when required, repair/replacement of defective unserviceable minor spare parts like nuts, bolts, washers, grease etc during the maintenance period and necessary periodical maintenance/checking as per the Manufacturer"s instructions and as directed. Model No Blue star for following Condensing unit M/C No, Model No BMC 206 (Location :Navjivani Hospital)
44Note for Sl item Nos 29 to 33:- Unit rates quoted by the tenderer shall be deemed to included the following :- (i) Routine services during the period. (ii) Immediate attendance and rectification of breakdown, if any. (iii)Checking the functioning of Chiller unit/Air Handling unit/Pumps/Controls (iv) De-scaling of condensers/cleaning of evaporator coils based on our assessment and working parameters of the plant (v) Replacement of unserviceable sensors/ control boards (vi) Free repairs and replacement of defective/worn out components which are integral to the functioning of the equipment (vii) Replacing refrigerant gas and compressor oil in the system arising out of system defect. (viii) Repairs to the refrigerant pipes in case of leaks (ix) Quarterly cleaning of HEPA filters and its required repairs (x) Pumping-down and restarting as and when required (xi) Checking of Microprocessor control panel, control boards, transducers of packaged chillers/condensing unit for their correctness and replace if necessary (xii) Replacement of other unserviceable electric and mechanical parts of AC unit.(xiii) Procurement of stationary and cleaning materials such as waste cloths etc.
45Taking down secondary monoblock pump three Phase 5HP capacity, dismantling motor end covers, cutting and taking out burnt out stator windings complete, cleaning slots, removing dust/dirt, rewinding with the same gauge super enameled copper winding wire with insulating material, varnishing heating replacement of bearing DE and NDE ends, refixing same and ensure its serviceability complete all as specified and as directed . Model No Kirloskar KDS 536.
46Supply and fix in replacement of compressor complete including taking down of old compressor and re-filling of refrigerant (gas) as per site requirement including gas etc and testing on completion complete all as specified and as directed for the following :-
47AC Plant 12 TR
4815000 BTU low temperature cold room
4920000 BTU low temperature cold room.
50Supply and fix in replacement of control PCB circuit (Microprocessor) for 24 TR AC plant unit complete including taking down of old unserviceable PCB and testing on completion complete all as specified and as directed.
51Supply and fix in replacement of expansion valve complete including taking down of old unserviceable expansion valveand testing on completion complete all as specified and as directed for the following:-
52AC Plant 24 TR
5315000 BTU low temp cold room
5420000 BTU low temperature cold room.
55Supply and fix in replacement of relay contactors complete including taking down of old unserviceable contactors and testing on completion complete all as specified and as directed for the following:-
56AC Plant 24 TR
5715000 BTU low temp cold room
58Supply and fix in replacement of indoor fan and fan motor set complete including taking down of old unserviceable fan and fan motor for cold room indoor unit and testing on completion complete all as specified and as directed.
59Supply and fix in replacement of AHU air filter of following sizes :-
60610 mm x 610 mm x 40 mm with aluminium frame pre filter including base frame shutter all as specified and as directed.
61210 mm x 610 mm x 40 mm with aluminium frame pre filter including base frame shutter all as specified and as directed.
62Supply and charging R22 gas suitable for AC plant and cold room unit as and when required complete all as specified and as directed.
63Supply and charging R410A gas suitable for VRV unit complete all as specified and as directed.
64Supply and charging R404 gas suitable for cold room unit complete all as specified and as directed.
65Supply and charging R407C gas suitable for 24 TR AC Plant units complete all as specified and as directed.
66Comprehensive maintenance and servicing every quarterly (once in a three months) for the following AC Plants including breakdown maintenance as and when required/ repair/ replacement of defective unserviceable minor parts like nuts, bolts, washers, grease etc during the contract period and necessary periodical maintenance/ checking as per the Manufacturer"s instructions and as directed by Engineer-in-Charge :- (i) Microprocessor based chiller water plant 200 TR (100x2) (Kautilya Auditorium AC Plant) Make :Blue Star Model:(JS 84 F-T 50 B) Equipements details :- (i) Water cooled reciprocating chiller of capacity 100 TR -02 Nos . (ii) Condenser water pump of capacity 20 HP -03 Nos. (iii) Chilled water pump primary of capacity 5 HP-03 Nos (iv) Chilled water pump secondary of cap 7.5 HP -05 Nos (v) Pump starting panel-02 Nos (vi)VFD panel -01 No (vii)Chiller starting panel-02 Nos (viii) Main LT Panel -01 No (ix) DG panel -01 No (x) Cooling tower -02 Nos
67(xi) Air handling units 20 TR 7000 CFM -02No (xii) Air handling unit 24 TR 8500 CFM-.01 Nos (xiii) Air handling unit 30 TR 15000 CFM -02 No (xiv) Air handling unit 50 TR 9000 CFM-01 No (xv) Air handling unit 11 TR 5000 CFM-01 No (xvi) Air handling unit 9 TR, 4000 CFM-01 No (xvii) Air handling unit 3 TR, 1500CFM-01 No, (xviii) Air handling unit 27.5 TR, 12000CFM-01 No, (xix) Air handling unit 10TR, 5000CFM-01 No, (xx) Air handling unit 30 TR, 14000CFM-01 No, (xxi) Air handling unit 6.5 TR, 3100CFM-01 No, (xxii) Air handling unit 9.5 TR, 4500CFM-01 No, (xxiii) Air handling unit 3.5 TR, 1500CFM-01 No
68NOTE FOR SL ITEM NO. 46:- (a) The rate quoted shall deemed to be included the following repairs works :- (i) Checking and calibration of Microprocessor. (ii)Oiling and greasing of equipments. (b)The rate quoted shall deemed to be included general servicing of electrical panels and labour charges for replacement of motor starter, MCCB, MCBs, contactors, panel board rewiring with copper conductor of suitable size and copper conductor for connection to motor from starter. (c)The rate quoted shall deemed to be included cleaning of cooling tower & surrounding area minimum once in one months for smooth functioning of all AC plants. (d)Material required for replacement shall be measured and paid for separately under the relevant items of this BOQ as "Supply and fix". (e) Record of checking shall be entered in a Register as directed by Engineer-in-Charge.
69Supply and fix Oil pressure Transducer suitable for blue star make JS84 Compressor, all as directed.
70Supply and fix HP/LP Transducer suitable for blue star make JS84 Compressor all as directed.
71Supply and charging compressor oil Suniso 3/4GS compressor oil after draining out old/unserviceable compressor oil complete all as directed.
72Dismantling end covers of shell and tube condenser and evaporator, cleaning of copper tubes with acid / soap water with nylon brush to remove the scaling inside the tubes and ensure / confirm the flow of chilled water at head pressure within permissible limit all as specified and as directed by Engr-in-Charge.
73Dismantling and taking down defective primary chilledwater pump motor up to 5 HP , AC, 3 phase, 415 volts of capacity 240 USGPM at 12 meter head, opening of motor end shield covers, cutting and taking outburnt out copper windings, cleaning winding slots and rewinding with super enameled copper winding wire of suitable size and checking the continuity, insulation values, applying varnish, heating and drying and replacing the terminal block, testing completeto the entire satisfaction of Engineer-in-Charge.
74All as per Sl item No. 48 above but above 5 HP to 10 HP for Secondary chilled water pump motor of capacity 288 US GPM at 20 M head all as specified and directed by Engr-in-charge.
75All as per Sl item No.48 above 10 HP to 15 HP for Secondary chilled water pump motor Of capacity 240 US GPMat 15 M head all as specified and directed by Engr-in-charge.
76All as per Sl item No.48 but 20 HP for condenser water pump motor Of capacity 400 US GPMat 20 M head all as specified and directed by Engr-in-charge.
77Replacement of Impeller and mechanical seal for item no. 39 to 42 above all as directed.
78Dismantling motor from floor mounted / ceiling suspended double skin horizontal AHU/Cooling towerand opening motor end shield covers cutting and taking out the burnt out copper windings, cleaning the winding slots and rewinding with super enameled copper winding wire of suitable size and checking the continuity ,insulation values, applying varnish, heating and drying and replacing the terminal block testing of following capacities in library and Auditorium of following capacities :-
79Up to 3 HP capacity
80Above 3 HP to 5 HP
81Above 5 HP to 7.5 HP
82Supply and fix Fan V Belt for the FMU 7000 CFM capacity (Model 50A#)
83Supply and fix Fan V Belt for the FMU 8500 CFM capacity (Model 49A#)
84Supply and fix Fan V Belt for the FMU 9000 CFM capacity (Model 56A#
85Supply and fixFan V Belt for the FMU 12000 CFM capacity (Model 66B#)
86Supply and fixFan V Belt for the FMU 14000/15000 CFM capacity (Model 76B#)
87Supply and fixFan V Belt for the CSU 1500 CFM capacity (Model 36B#)
88Supply and fix Fan V Belt for the CSU 3100 CFM capacity (Model 23B#)
89Supply and fixFan V Belt for the CSU 4000 CFM capacity (Model 27B#)
90Supply and fix Fan V Belt for the CSU 4500/5000 CFM capacity (Model 31A#)
91Preparing old painted steel surfaces of any description, not otherwise described, over 10cm in width or girth and applying two coats of synthetic enamel paint complete all as specified and as directed.
92Taking down of expansion tank monoblock pump 1/2 HP capacity and dismantling motor end covers cutting and taking out of burnt out stator windings complete and cleaning the slots removing all dust / dirt rewinding with same gauge super enameled copper winding wire with insulating material varnishing heating replacement of bearing DE & NDE ends refixing the same and ensure its serviceability complete all as specified and as directed.
93Supply and fix DOL starter for 3 HP motor
94Supply and fix Single Phase preventer
95Supply and fix Stem filled Alcohol Thermometer.
96Supply and fix Pressure gauges with 4 inch dia 1-100 bar
97Supply and fix Pressure switch - Danfoss
98Supply and fixing of Noise filter for VRV/VRF outdoor unit including taking out old/ unserviceable Noise filter complete all as specified and as directed.
99Supply and fix in replacement of PCB circuit for cold room plant unit complete including taking down of old unserviceable PCB and testing on completion complete all as specified and as directed.
100Supply and fix in replacement of Heater for cold room plant unit complete and required suitable aluminium tape including taking down of old unserviceable PCB and testing on completion complete all as specified and as directed.
101Supply and fix in replacement of Sensor complete including taking down of old unserviceable PCB and testing on completion complete all as specified and as directed.
102Supply and fix in replacement of Contractor suitable for AC plant unit of capacity 32/40 Amps complete including taking down of old unserviceable Contractor and testing on completion complete all as specified and as directed.
103Supply and fix in replacement of Contractor suitable for AC plant unit of capacity 9/16 Amps complete including taking down of old unserviceable Contractor and testing on completion complete all as specified and as directed.
104Supply and fix in replacement of suction/liquid line Sensor complete including taking down of old unserviceable PCB and testing on completion complete all as specified and as directed.
105Supply and fix in replacement of Fan PCB board suitable for VRV unit any capacity complete for outdoor unit including taking down of old PCB and required connections and testing on completion etc complete all as directed. Make as per OEM.
106Dismantling end covers of evaporator and drain out chilled water from evaporator to all connecting chilled water line of AHU, cleaning of all strainers /filters connected in chilled water line, cleaning with fresh water / acid to remove the scaling inside the tubes and ensure / confirm the flow of chilled water at head pressure within permissible limit all as specified and as directed by Engr-in-Charge. Note : All T&P required for cleaning will be arranged by contractor and no extra cost will be pay on this account.
107Supply and fix in replacement of compressor 18 HP suitable for VRV unit completeincluding taking down of old compressor and re-filling of refrigerant (gas) as per site requirement including gas etc and testing on completion complete all as directed. Make as per OEM.
108Supply and fix in replacement of compressor 10 HP suitable for VRV unit complete including taking down of old compressor and re-filling of refrigerant (gas) as per site requirement including gas etc and testing on completion complete all as directed. Make as per OEM.
109General Notes : 1. Contractor should visit at sitebefore quoting the tender to know the working condition of the station.2.All requisite safety measures are to be adopted by contractor on site. 3. The contractor shall provide and deploy one no. skilled AC planttechnician(as approved by GE / Engineer-in-charge) and shall report at 0900 hrsto JE E&M /Engineer-in-chargeto collect the complaints of AC Plants at every working day. The amount for payments of AC plant technicianshall included in quoted rates. the contractor shall also provide AC plant technician on Sunday & holiday if required or asked by JE E/M / Engineer-in-charge. If the contractor failed to provide their AC plant Technician or absent to attend the complaints then recovery will be done@ Rs 1500.00 perday. 4. The complaints shall be rectified with in 24 hrs. If the complaints are not attended /not completed within 24 hrs (except repair/ replacement of major parts) recovery will be done @Rs 1500.00 per complaint per day. 5. For major Parts, complaints should be rectified within 07 Working days, if the contractor not rectify within time then recovery will be done @ Rs 2000.00 per complaint per day.
110Schedule of Credit (Minus) Rs. 31589.00 NOTE: Bidder shall insert credit amount of Rs. 31589.00 as ratein Green field under Col-5.