|
| 1 | Supplying, installation, testing & commissioning of 20 passenger gearless and machine room less lift having contract speed of 1.0 meter/per second as per specifications as under complete with all the equipment and accessories.(i) Drive : Micro Processor Based VVVF(ii) Travel / PIT / Headroom : 6.25 Meter / 1800 mm / 4800 mm(iii) Number of Floors : 2 (G+1)(iv) Floor Display Char : 0,1(v) Number of Landing Entrances : 2 (G+1)(vi) Number and Position of Car Entrances : 1 (ONE), In Front Only(vii) Size of Lift Well : 2550 X 2450 (mm Wide x mm Depth)(viii) Lift Car Inside Size : 1700 X 1800(mm Wide x mm Depth)(ix) Clear opening : 1000 X 2000 (mm Wide x mm Height)(x) Type or Design of Lift Car : Stainless Steel in Honeycomb Finish with 1.5 mm thickness (304 Grade)(xi) Car Ceiling & Flooring : As per OEM(xii) Car & Fan Fittings : AS per OEM(xiii) Type of Car Front Entrance Protection : Power Operated Center Opening Sliding Door : Stainless Steel in Honeycomb Finish with 1.5 mm thickness (304 Grade)(xiv) Land Entrance Protection (0,1) : Center Opening Sliding Door : Stainless Steel in Honeycomb Finish with 1.5 mm thickness (304 Grade)(xv) Landing Door Frame (0,1) : Stainless Steel in Hairline Finish (304 Grade)(xvi) Type Of Control System : Micro Processor Based VVVF Simplex Selective Collective Control with / without attendant(xvii) Electric Supply : AC 400/440 Volts, 03 Phase, 50 Cycles(xviii) Special Inclusions : Special Inclusions : detailed specifications |
| 2 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.(a) Group \"C\" |
| 3 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.(a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 4 | (b) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 5 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 6 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)(a) 12 way, Double door |
| 7 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)(a) 4 way (4 + 12), Double door |
| 8 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.(a) Single pole |
| 9 | (b) Single pole and neutral |
| 10 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.(a) 100 amps |
| 11 | Supplying, installation, testing & commissioning of 18 watt surface mounted glarefree round LED downlight, system lumen efficancy 90Lm/W, cool day light (5700K to 6500K), power factor>0.90, CRI>80, LED lamp complete with all accessories, testing & commissioning etc. as required. |
| 12 | Supplying, installation, testing & commissioning of LED surface mounted 10 watt IP66 (waterproof) glarefree, pressure die cast aluminum housing with unbreakable polycarbonate diffuser bulk head fitting. Total system Lumen of 10W LED should be 550 or above in cool day light (5700K to 6500K), power factor>0.95, CRI>75. complete with all accessories as required i/c connections with 1.5 sq. mm PVC copper wire etc. as required. |
| 13 | Supplying, installation, testing & commissioning of energy efficient 45 - 50 Watts LED post top lantern luminaries complete with accessories and suitable size clamp, nut bolt on the existing street light pole including connection with 1.5 sq mm FRLS PVC insulated copper conductor single core cable complete etc. as required. The LED fitting should confirm to the following technical specifications :- a. High power cool white LED with LM 80 test report.b. Life span of LED’s used should be greater then 50,000 hours out put.c. Colour rendering index(CRI)>80%d. Colour temperature of luminaries shall be 5700°K to 65000°Ke. LM -79 test report of fittings f. Power factor>0.95g. System Efficiency > 100 lumen/watt h. Operating voltage 140 Volts to 270 Voltsi. Total Harmonic distortion <10%j. LED drive current 350 MA to 1000 MAk. LED drive efficiency>85%l. Housing :- Pressure Aluminum die Cast(thermal and impact resistance =IK-07m. Ingress Protection - IP : 65n. Safety :- As per IEC 62471o. Cover :- It should be equipped with distoration free, clear heat resistant toughned, UV stablized glass / poly carbonate cover glare freep. Driver specifications :- 140-270 Volts universal Electronic driver with internal surge protection of minimum 5 KVq. Operating temperature-10°C to + 50°Cr. Fitting size should not less than height 420mm x width 330mm x mounting dia 80mm [Dimension tolerance ± 5mm] |
| 14 | Supplying, laying and fixing of following size PVC insulated and PVC sheathed/ XLPE aluminum conductor armoured power cable of 1.1 KV grade in following manner etc. as reqd.(a) 3 x 6 sq.mm on wall surface |
| 15 | (b) 3.5 x 35 sq.mm on wall surface |
| 16 | (c) 4 x 25 sq.mm on wall surface |
| 17 | (d) 4 x 25 sq.mm direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering |
| 18 | Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum conductor cable of 1.1 KV grade as required.(a) 3½ X 35 sq. mm (32mm) |
| 19 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etcdirect in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.(a) 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 20 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.(a) Hot finished welded type tubes |
| 21 | Providing and fixing precoatedgalvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling / self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 22 | Fabrication, Supplying and installation of indoor type cubical feeder pillar of surface area/size of 1 sq meter with minimum depth of 35 cm made out of CRCA M.S. Sheet 2 mm Thickness (14 SWG) duly compartmentalized having 4 strip bus bar of 200 Ampers capacity double door with double locking arrangement (one sliding lock in front and one godown lock each at front and rear for protection) dust proof vermin process, duly fixed on M.S. angle iron frame work of size 50 mm X 50 mm X 6 mm (NS) 90 cm long legs, out of which 45 cm duly grouted in cement concrete foundation of size 30 cm X 30 cm X 50 cm deep 1:2:4 (1 cement : 2 Coarse sand : 4 graded stone aggregate 20 mm nominal size) duly painted with one coat of red oxide & two coats of superior quality enamel paint in approved shade and colour complete etc. as required including supplying & fixing of following accessories in the feeder pillar complete with testing, earth studs, earth strips etc. as required. |
| 23 | Supplying & Fixing the following accessories in the above feeder pillar board etc. as required.(a) 200 A, 25 kA,TPMCCB |
| 24 | (b) 100 A, 16 kA,TPMCCB |
| 25 | (c) Digital type Volt Meter (0-500 Volts) with selector switch |
| 26 | (d) Digital type Ammeter (0-250 ampers) with selector switch |
| 27 | (e) Indicating Light LED type with 2 Ampers SP MCB (3 Nos.) |
| 28 | (f) 200/5 Amp. CT - 3 Nos. |
| 29 | (g) Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
| 30 | Supplying, installation, testing & commissioning of 40KVA capacity Servo motor controlled, 3 Phase, 50Hz, voltage stabilizer copper wound for automatic controlling/ regulating of voltage comprising of auto transformer, servo motor, solid state control circuit, oil filled alongwith allied accessories etc as required:-1. Voltmeter (0 to 500 Volts) to read input & output voltage per phase2. CT operated Ampere Meter (0 to 500 Volts)3. Selector switch to measure the load independently4. Main/ Low/ High Indicator5. Manual increase/decrease push switch6. Auto/ Manual Switch7. Output Voltage adjustment in auto modeTechnical SpecificationInput Voltage 300Volts- 470VoltsOutput Voltage400Volts ± 2.5%Cooling Oil cooledCapacity 40 KVAProtectionBy pass arrangementShort Circuit ProtectionOver Load ProtectionIst Filling of transformer oil |
| 31 | Fabricating, supplying & fixing of wiremesh protection frame work fabricate with 40x40x6 mm thick angle iron & tee iron of 40x40x6 mm thick by making blocks of not less than 90x90 cm in frame including providing & fixing wire mesh of section 75mm x 25mm of 8 SWG & having weight not less than 7.5 kg/Sq.Mtr. and shall be fixed with 25x3 mm thick MS flat frame & all frame work is to be painted with two or more coat of Red Oxide primer & two coat of synthetic enamel paint etc as reqd. |
| 32 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 33 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 34 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 35 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 36 | Comprehensive maintenance of 20 passenger lifts - 2 Nos., which include routine, preventive and breakdown maintenance including repair/replacement of worn out parts with minimum downtime and warranty and guarantee of repaired/replaced parts, after completion of defect liability period etc.(a) 1st Year after defect liability period |
| 37 | (b) 2nd Year after defect liability period |
| 38 | (c) 3rd Year after defect liability period |
| 39 | Credit of old damaged remaining parts/material of lifts & other electrical accessories etc. complete as required. (Note :- The dismantle material shall be taken back by the contractor as it is basis) |