Military Engineer Services-MES has published Tender For Addition/ Alteration And Improvement To Toilet At Boat Pool (Bldg No P-164) And Provision Of Bus Shelter Near Main Gate At Ins Mandovi Under Ge (P) Navy Mandovi. Submission Date for this Tender is 21-02-2023. Commercial Marine Vehicle Tenders in North Goa Goa. Bidders can get complete Tender details and download the document.




Tender Notice

35954160
Corrigendum : Tender For Addition/ Alteration And Improvement To Toilet At Boat Pool (Bldg No P-164) And Provision Of Bus Shelter Near Main Gate At Ins Mandovi Under Ge (P) Navy Mandovi
Open Tender
Indian
Goa
North Goa
21-02-2023

Tender Details

Addition/ Alteration And Improvement To Toilet At Boat Pool (Bldg No P-164) And Provision Of Bus Shelter Near Main Gate At Ins Mandovi Under Ge (P) Navy Mandovi As Per Tender Documents

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 09-Feb-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 16-02-2023
2 16-Feb-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 21-02-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 17000.0 /-
Tender Value
INR 8.50 Lakhs /-

BOQ Items

Name of Work:
Sl. No. Item Description
1B/R PORTION
2M & L for rendering 10 mm thick on fair faces of brick work or concrete surfacesin cement mortar 1:6, finished even and smooth without using extra cement complete all as specified and directed.
3Taking down cement or cement lime plaster, any description on stone/ PCC block/ brick wall or top of chajja including raking out joints, hacking for key, scrubbing down with water etc and removal of debris to outside of INS Mandovi area including filling of open joints in cement mortar 1:6 complete all as specified and directed.
4M & L for rendering 15 mm thick in two layers in cement mortar 1:3, 10 mm thick first layer and 5 mm thick outer layer mixed with WPC as per manufacturer"s instructions on fair faces of brickwork or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed. Note: WPC shall be measured and paid separately.
5Supply only integral waterproofing compound complete all as specified and directed.
6M & L for preparation of newly plastered wall surfaces, priming with alkali resistant priming paint, applying 1 mm thick wall care putty wherever required and distempering with two coats of distemper oil emulsion, white or tinted, complete all as specified and directed.
7M & L for preparation of newly plastered wall surfaces and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed.
8Demolition of brickwork or stone/ boulder masonry, built in cement mortar for ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
9M & L for pre-cast cement concrete block masony with solid blocks of precast cement concrete 1:3:6 type C1 (using 20 mm graded stone aggregate), exc 10cm in width and set in cement mortar 1:6 complete all as specified and directed.
10Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
11M & L for rendering 10 mm thick onfair faces of brick work or concrete vertical surfaces in cement mortar 1:4 complete all as specified and directed.
12M & L for glazed ceramic coloured tiles in vertical surface, 300 x 200 x 7 mmthick, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
13M & L for providing 15mm thick screed bed or bedding layer of cement mortar 1:4for laying floor finishes complete all as specified and directed.
14M & L for providing non - skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular), area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
15M & L for provinding 25 mm thick cement concrete 1:2:4 type B0 (using 12.5mm graded stone aggregate) on concrete surface over top of RCC roof using waterproofing compound as per manufacturer instruction finished even and fair using extra cement complete all as specified and directed. Note: Quoted rate shall be deemed to be inclusive of cost of waterproofing compound.
16Dismantling/ taking down existing hessain base felt or clay tiles or any other existing water proofing treatment from roof/ chajja including cement plaster, cleaning the surface and removing the dismantled debris to a distance exceeding 1.50 km but not exc 5 km to outside the MD land and laying water proofing membrane treatment using 4mm thick APP modified membrane consisting five layer membranes, weighing not less than 4.00kg/sqm laid over a coat of cold bituminous primer @ 0.40 kg/sqm by torching the membrane and sealing the overlap by 100mm length side and 150mm width side all as per manufacturer"s instructions including joints and changes in direction be curved with 10mm thick cement mortar 1:3 mixed with SBR latex @ 2.00ml/bag of cement, curved well before laying of membrane, including applying two coats of solar reflective bituminous aluminium paint @ 0.10 litre/sqm complete all as specified and directed.
17Cutting chases, pinning in, making good to facings where required and pointing in CM 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc, and cutting chases for concealed water tubing, or concealed conduit wiring etc and making good, cutting not exc 10 cmgirth in brick walls complete all as specified and directed.
18S & F 75 mm dia bore PVC (SWR) pipes, single socketed in any length with rubber ring joints, solvent cement jointed fixed to walls complete all as specified and directed.
19S & F 110 mm dia bore PVC (SWR) pipes, single socketed in any length with rubber ring joints, solvent cement jointed fixed to walls complete all as specified and directed.
20S & F PVC (SWR) floor trap of 75 mm dia outlet, plain with grating including jointing with solvent cement complete all as specified and directed.
21S & F PVC (SWR) bends of 75 mm dia bore, any radius, complete all as specified and directed.
22S & F PVC (SWR) bends of 110 mm dia bore, any radius, complete all as specified and directed.
23S & F PVC (SWR) vent cowl of 110 mm dia bore complete all as specified and directed.
24S & F PVC (SWR) reducer of 110 mm dia bore complete all as specified and directed.
25S & F in repairs pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered hot or cold with long screwed shanks and fly nuts, screwed for iron pipes of 15 mm dia bore complete all as specified and directed.
26S & F non return flap valve fitted on to end of the sanitary sewage pipe of 110mm dia, high quality polypropyiene and stainless steel ending complete all as specified and directed.
27M & L for concrete bed to drain pipes of 150 mm bore including packing under, and haunching against the sides of pipes after they are laid and tested; in cement concrete 1:3:6 type C2 complete all as specified and directed.
28S & F automatic soap dispenser with infrared sensors to detect hands before the dispenser valve and the soap dispencer pump complete all as specified and directed.
29S & F hand drier with sensing range 12cm+/3cm RPM 2800 drying time less than 20 sec complete all as specified and directed.
30S & F floor mats of standard size 20 x 30 inches complete all as specified and directed.
31S & F in repairs brass chromium plated shower rose, 125 mm size with or without swivel joints, including fixing to steel pipe or union of 15mm dia bore complete all as specified and directed.
32S & F in repairs stop valves, fancy type, cast copper alloy (concealed type), screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions of 15 mm dia bore complete all as specified and directed.
33S & F vitreous China bowl urinal, lat back, size of 465 x 355 x 265 mm (minimum), white, with grating and union for discharge pipe including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and union for discharge pipe (exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified and directed.
34S & F in repairs PVC connections of size 15 mm, 450 mm long with check nuts at both ends complete all as specified and directed.
35S & F in repairs brass, tubular towel rail, chromium plated, 20mm dia, D type, 60cm long between flanges complete all as specified and directed.
36Taking up or down steel tubing and connections of 15 mm dia bore complete all as specified and directed.
37Taking up or down steel tubing and connections of 20 mm dia bore complete all as specified and directed.
38Supplying and laying of CPVC pipe SDR 11 & plain CPVC SDR 11 fittings of 20 mm dia on walls/ ceiling or laying in floors complete all as specified and directed.
39Supplying and laying of CPVC pipe SDR 11 & plain CPVC SDR 11 fittings of 25 mm dia on walls/ ceiling or laying in floors complete all as specified and directed.
40S & F vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe), including seat cover complete all as specified and directed.
41S & F in repairs PVC valveless, syphonic action type, flushing cistern of 10 litres capacity, low level, white, with inlet, ball valve, float and handle including brackets and flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cistern and connections to pipes and fixing of chain and pull, or lever, if any complete all as specified and directed.
42S & F in repairs health faucet with hook and flexble arm, chromium plated, with 1.5 m tube suitable for 15 mm dia bore pipe complete all as specified and directed.
43S & F in repairs angle stop valves, fancy type, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends, for iron pipes or for unions of 15 mm dia bore complete all as specified and directed.
44S & F in repairs bib taps, fancy type, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule of 15mm dia bore complete all as specified and directed.
45Dismantling water tanks of capacity exc 500 ltr & n exc 1000 ltr and removing to store complete all as specified and directed.
46S & F 2000 litre capacity rotational moulded polyethylene water storage tanks (cylindrical, vertical with closed top) hoisted and fixed in position complete all as specified and directed.
47Taking down chowkats or frames exceeding 1.5 sqm but not exceeding 4.0 sqm each, with shutters complete all as specified and directed.
48S & F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. square tube, fixing in opening as per specification and drawing complete all as specified and directed.
49S & F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification complete all as specified and directed.
50M & L for hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface using broken stone or boulders complete all as specified and directed.
51M & L for providing 100 mm thick cement concrete 1:3:6 type C2 using 40 mm graded stone aggregate, finished even and smooth without using exra cement as in sub-floor, sub-base, floors etc complete all as specified and directed.
52Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/dense soil complete all as specified and directed.
53M & L for providing cement concrete 1:3:6 type C2 using 40mm graded aggregate as in surface channels and drains complete all as specified and directed.
54Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in hard/dense soil complete all as specified and directed.
55Removing excavated soil to a distance n exc. 50 m and depositing where directed complete all as specified and directed.
56M & L for providing precast cement concrete 1:2:4 type B1 using 20mm graded stone aggregate in landings, cover slabs (for man holes etc.), slab supported on wall beams and columns in floor roofs, shelves and similar articles with plain faces including chamfers, weatherings, throating etc. and setting in mortar 1:4 complete with joints to match complete all as specified and directed. Note: Reinforcement steel shall be measured and paid separately under relevant item of Schedule "A".
57M & L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
58Surface excavation n.exc 30 cm deep and averaging 15 cm deep and getting out in soft / disintegrated rock complete all as specified and directed.
59Excavating in post holes (or similar holes) each n.exc 0.5 cum, getting out in soft/ disintegrated rock, returning, filling in ramming earth or broken rubble mixed with earth around in layers n. exc 25 cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface complete all as specified and directed.
60Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/integrated rock complete all as specified and directed.
61M & L for providing cement concrete 1:3:6 type C2 using 40mm graded aggregate as in foundations, filling and mass concrete complete all as specified and directed
62M & L for providing cement concrete 1:2:4 type B2 using 40mm graded aggregate as in walls or retaining walls, any thickness, size or shape including pilasters, buttresses, columns, pillars, boundary pillars and posts (including caps and bases), including necessary form work complete all as specified and directed
63M & L for rendering 10 mm thick on fair faces of brick work or concrete surfacesin cement mortar 1:4, finished even and smooth without using extra cement complete all as specified and directed.
64M & L for providing cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) in lintels upto 1.5m clear span, cills, steps; copings, kneelers, apex stones, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including necessary form work complete all as specified and directed.
65M & L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
66M & L for providing machine pressed precast conctete interlocking paver block any shape and size, of 60 mm thickness, M-35 grade (rubber moulded), confirming to IS 15658-2006, fixed with grey cement & pigment complete all as specified and directed.
67Removing excavated rock to a distance exc. 250m and n exc. 500 m and depositing where directed complete all as specified and directed.
68Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft disintegrated rock complete all as specified and directed.
69S & F roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc in Fe-290 Gde E-165 complete all as specified and directed.
70S & F steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161- 1979 grade St. 240 complete all as specified and directed.
71S & F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet, 0.50mm thick, of any colour, having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
72S & F mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk), forming holes, with riveted, bolted or welded attachment confirming to Fe 410-W(Gde-E-250) Quality-A complete all as specified and directed.
73M & L for preparation of new or previously untreated steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
74INTERNAL ELECTRIFICATION
75Taking down copper/ aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. and making good disturbed surfaces of walls, floors, etc to match existing surface complete all as specified and directed.
76M & L for point wiring complete with 1.5 Sqmm 1100 volts grade single core PVC insulated unsheathed cable with multistranded copper conductor confirming to IS-694, Part II, ISI marked, drawn through and including medium grade PVC conduit of size not less than 25mm dia, ISI marked with all accessories, concealed in wall/ ceiling, sunken switch / terminal box 1.12 mm thick, suitable for 3mm thick laminated hylem sheet or plastic masonite laqminated sheet top cover fixed with chromium plated brass screws for fixing switches, sockets, regulators etc., and including providing 1.5 sqmm 1100 volts grade single core PVC insulated unsheathed cable with multistranded copper conductor in green colour as earth continuity conductor connected to common earth dolly for one light / fanpoint controlled by one switch complete all as specified and directed. Note: Quoted rate shall be deemed to be inclusive of cutting chasis in wall/ floor/ ceiling and making good disturbed surface with PCC work and paint etc.
77All as per item no 76 here-in-before but for switch socket combination 5 Amp on independent board complete all as specified and directed.
78S & F in repairs switch socket combination 5 pin and 6 Amp, flush type for 230 volt 50 HZ AC supply complete all as specified and directed.
79S & F in repairs ceiling rose, 3 terminal, PVC polycarbonated isolated body complete all as specified and directed.
80S & F in repairs switch piano, 6 amp, single pole, one way, flush type, complete all as specified and directed.
81S & F exhaust fan, 300 mm sweep, for single phase 230/240 volt 50 Hz AC supply, steel body with louvers, with suitable MS bracket, nuts, bolts and fixing arrangement, including making holes and PCC work as per site requirement complete all as specified and directed.
82S & F sheet metal enclosure for MCB"s (D.B), single door, SPN 2 way, 240 Volts complete all as specified and directed.
83S & F LED flood light fitting, 100 watt, outdoor type, for 230 V 50Hz AC supply, suitable for operation over voltage range of 160 V to 260 V duly housed in pressure die cast aluminium housing comprising of LED lamp with individual optical lens, electronic driver with surge protection and PF more than 0.90 confirming to IP 66, cool day light output and connecting with existing feeder/ceiling rose with 1.5 sqmm 3 core copper cable multistranded conductor including fixing the fitting to GI bracket with suitable size clamps with bolts, nuts and washers complete all as specified and directed.
84S & F in repairs LED tube light fitting 1 X 10 watt, baton T5 mushroom type with integrated LED chanel, integral sleek extruded polycarbonate LED channel with white acrylic cover, alongwith LED tube including connecting with three core flexible copper conductor cable of suitable size from ceiling rose to fitting duly mounted on PVC block with steel screw andsleeves complete all as specified and directed.