Tender For Development Of Distribution Infrastructure At Kozhikode District (Electrical Circle,Kozhikode And Electrical Circle, Vadakara) Of Kerala State Under Revamped Reforms-Based And Results-Linked, Distribution Sector Scheme (Rdss)- (Schedule Of Rate, kozhikode-Kerala

Kerala State Electricity Board-KSEB has published Tender For Development Of Distribution Infrastructure At Kozhikode District (Electrical Circle,Kozhikode And Electrical Circle, Vadakara) Of Kerala State Under Revamped Reforms-Based And Results-Linked, Distribution Sector Scheme (Rdss)- (Schedule Of Rate. Submission Date for this Tender is 02-02-2023. Cutting Crimping and Punching Tools Tenders in kozhikode Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

35925105
Corrigendum : Tender For Development Of Distribution Infrastructure At Kozhikode District (Electrical Circle,Kozhikode And Electrical Circle, Vadakara) Of Kerala State Under Revamped Reforms-Based And Results-Linked, Distribution Sector Scheme (Rdss)- (Schedule Of Rate
Open Tender
Indian
Kerala
kozhikode
02-02-2023

Tender Details

Development Of Distribution Infrastructure At Kozhikode District ( Electrical Circle, Kozhikode And Electrical Circle, Vadakara ) Of Kerala State Under Revamped Reforms-Based And Results-Linked, Distribution Sector Scheme ( Rdss ) - ( Schedule Of Rates And Prices ) - Ex-Works Supply Of Materials-3 Hdpe Pipepn 6 Configuration And Pe Grade 80 4 110 Mm 5 150Mm 6 160 Mm 7 Class B4.8 Mm Thick Gi Pipe 8 150 Mm 9 Heat Shrinkable Cable End Termination Kit Suitable For 3 X 300 Sqmm Ug Cable 10 Outdoor Type 11 Heat Shrinkable Straight Joints Using Shear Bolt Type As Per Is 13573 Part Ii 2011 With Dual Wall And Single Triple Extruded Hybrid Tubing With Shear Bolt Connector As Per Iec 61238, Of Rating 300 / 400 A 12 Poles For The Construction Of Dps / Cut Pole 13 Psc Poles 9M- 487 Kg 14 Galvanized A Poles 11 M ( Hot Dip Galvanized ) 15 Prefabricated Materials Like Cross Arms, Clamps, Bolts And Nuts, Gi Wire Of Size6 Swg, Gi Strip Of Size 25 X 3Mm Etc 16 40 Mm Dia., 3000 Mm Longclass B Gi Pipe Earth Electrode , Withaccessories Complete 17 6Kg 10 Inch Pvc Pipe Of Length 30 Cm Withpvc End Cap 18 Earth / Groundenhancementmaterial 19 Properly Cured Reinforced Concrete Slabs Of Size 40 X 30 X 5 Cm , 1 : 1.5 : 3Cement Concrete With6mm Baby Metal Using 6 Mm Tmt At 10 Cm C / C -With Markings As Specified 20 Cable Route Markeras Per Specification 21 Station Classpolymer Type La, 9 Kv, 10 Ka With All Accessories 22 12Kv, 400Amps , 25Ka For 3 Sec , 3Phase, 3Pin Type Horizontal Mounting Type Gang Operated Ab Switch Along With Support Insulators Base Channel Down Pipe Arcing Horns Etcs Complete As Per Technical Specifitions. 23 Rdss Sign Board As Per Specifications 24 Hot Dip Galvanized Stay Set With Anchor Plate Size 300X300x10mm, 50 / 8Mm Stay Clamp, Stay Insulators 2Nos, Nuts, Bolts, Stay Tightners / Turn Buckle, 1.8 M Long 20Mm Dia Solid Gi Stay Rod And 7 / 3.15Mm Dia Gi Stranted Wire As Per Technical Specifications Approved Works And As Per Drawing. 25 Boq-2 - 11 Kv Aerial Bunched Cables 26 Poles For 11 Kv Abcline As Per Technical Specifications Approved Works And As Per Drawing. 27 Psc Pole 9M- / 487 Kg 28 A Pole - 10 M- Vertical Member Isa 90X90x8mm;O / O Spacing 90Mm At Top & 350Mm At Bottom; Horizontal Ties Isa 50X50x6mm; Bottom Support Horizontal Ties- 500 Mm 29 A Poles 11 M---Do -- Horizontal Ties Isa 50X50x6mm; 30 A Pole 12 M-- Do - Horizontal Ties Isa 65X65x6mm; 31 A Pole 14 M 14M Vertical Member Isa 100X100x8mm -- Diagonal Tie 50X50x8mm; Horizontal Ties Isa 65X65x6mm;Bottom Support Horizontal Ties- 580 Mm 32 Pscc Spun Pole 9.5M ( Structural Concrete M25 ( 1:1:2 ) , 700 Kg As Per Is 13158; 1.5M Below Gl, Pcc In A Pit 2M X 0.6M M15 ( 1:2:4 ) 20 Mm Size Stone Aggregate Chips 33 Four Legged Pole 34 Supply Of 11Kv Abc As Per Technical Specification And Scope Of Work. 35 3X120+1X95sqmm ( Insulated Messenger ) 36 Single Core Removable And Re Usable Tee For 11Kv Abc ( Mvt ) ( Set Of 3Nos ) 37 Special Channel Cross Arm For Fixing The Mvt, La With Bolt And Nuts, Earthwireetc. 38 11Kv End Termination Kits 39 Suitable For 120Sqmm 40 Abc Accessories 41 Heat Shrinkable Tube 42 Anchor Clamp Or Dead End Clamp Suitable For Ht Abc 43 Suspension Clamp Suitable For Ht Abc 44 Stainless Steel Strap 45 Stainless Steel Buckles 46 Cable Ties Uv Plastic Heavy Duty Around 250Mm Long 47 Ligthning Arrester 48 9Kv 5Kamps Polymeric Surge Arrester Distribution Classs ( 3Nos Per Set ) 49 9Kv 10Kamps Polymeric Surge Arrester Station Classs ( 3Nos Per Set ) 50 40 Mm Dia., 3000 Mm Longclass B Gi Pipe Earth Electrode , Withaccessories Complete 51 6Kg 10 Inch Pvc Pipe Of Length 30 Cm Withpvc End Cap 52 Earth / Groundenhancementmaterial 53 Earthing Spike Made Of 12.5Mm Dia; 3000Mm Long Solid Low Carbon Copper Bonded Ms Solid Grounding Rod Treated With Derivatives To Prevent Oxidation Of Copper Bonding Along With Fittings 54 Lt Coil For Earthing ( 50Mm Dia, 115 Turns ) As Per Specification 55 Galvanized Stay Set With Anchor Plate Size 300X300x10mm, 50 / 8Mm Stay Clamp, Guy Insulators 2Nos, Nuts, Bolts, Stay Tightners / Turn Buckle, 1.8 M Long 20Mm Dia Solid Gi Stay Rod And 7 / 3.15Mm Dia Gi Stranded Wire As Per Technical Specifications , Scope Of Works And As Per Drawing. 56 Rdss Sign Board As Per Specifications 57 Pre-Fabricated Gi Channel Cross Arm, Bracket, Clamps, Galvanised Nuts, Bolts With Spring Washers Etc As Per Technical Specification, 58 11Kv 45 Kn, Polymeric Disc Insulators With Hardware Fittings 59 11Kv Polymeric Pin Insulator With Gi Pin 60 12Kv 400Amps , 25Ka For 3 Sec , 3Phase, 3Pin Type Horizontal Mounting Type Gang Operated Ab Switch Along With Support Insulators Base Channel Down Pipe Arcing Horns Etcs Complete As Per Technical Specifitions. 61 Boq - 3 - 11 Kv Reconductoring Using Bare Oh Acsr 62 Support Pole For 11 Kv Oh Line As Per Technical Specifications Approved Works And As Per Drawing. 63 Psc Pole 9M- / 487 Kg 64 A Poles 11 M---Do -- Horizontal Ties Isa 50X50x6mm; 65 Prefabricated Items Likes V Cross Arm ( 10.75Kg / Each ) , Pole Top F Clamp ( 1.5Kg / Each ) , Double C Cross Arm, Bracket, Clamps, Cross Bracings, Bracings, Strain Plate, Guarding Channels, Including Back Clamp, Etc Made Of Gi Channels, Angle, Flats Of Given Sizes For Over Head Structures, Gi Strip 25 X 3Mm, Gi Strip 25 X 6 Mm, 8 Swg Gi Wire, 6 Swg Gi Wire Etc As Per Technical Specification, Approved Drawings And Scope Of Work. 66 Ms Bolts And Nuts With Washers And Stud 67 Galvanized Stay Set With Anchor Plate Size 300X300x 10 Mm, 50 / 8Mm Stay Clamp, Guy Insulators 2Nos, Nuts, Bolts, Stay Tightners / Turn Buckle, 1.8 M Long 20 Mm Dia Solid Gs Stay Rod And 7 / 3.15Mm Dia Gi Stranted Wire As Per Technical Specifications Approved Works And As Per Drawing. 68 Polymeric Insulator With Accesoeries 69 11Kv 45 Kn, Polymeric Disc Insulators With Hardware Fittings 70 11Kv Polymeric Pin Insulator With Gi Pin 71 40 Mm Dia., 3000 Mm Longclass B Gi Pipe Earth Electrode , Withaccessories Complete 72 6Kg 10 Inch Pvc Pipe Of Length 30 Cm Withpvc End Cap 73 Earth / Groundenhancementmaterial 74 Lt Coil For Earthing ( 50Mm Dia, 115 Turns ) As Per Specification 75 Acsr Conductor With Following Types 76 Ascr Racoon 77 Rdss Sign Board As Per Specifications 78 Boq4 - Reconductoring 11Kv Lines Withabc 79 Poles For 11 Kv Abcline As Per Technical Specifications Approved Works And As Per Drawing. 80 Psc Pole 9M- / 487 Kg 81 A Pole - 10 M- Vertical Member Isa 90X90x8mm;O / O Spacing 90Mm At Top & 350Mm At Bottom; Horizontal Ties Isa 50X50x6mm; Bottom Support Horizontal Ties- 500 Mm 82 A Poles 11 M---Do -- Horizontal Ties Isa 50X50x6mm; 83 A Pole 12 M-- Do - Horizontal Ties Isa 65X65x6mm; 84 A Pole 13 M -- Do - Horizontal Ties Isa 65X65x6mm; 85 Supply Of 11Kv Abc As Per Technical Specification And Scope Of Work. 86 3X150+1X120sqmm ( Insulated Messenger ) 87 3X120+1X95sqmm ( Insulated Messenger ) 88 Single Core Removable And Re Usable Tee For 11Kv Abc ( Mvt ) ( Set Of 3Nos ) 89 Special Channel Cross Arm For Fixing The Mvt, La With Bolt And Nuts, Earthwireetc. 90 11Kv End Termination Kits For 3Phase 91 Suitable For 150Sqmm 92 Suitable For 120Sqmm 93 Abc Accessories 94 Heat Shrinkable Tube 95 Anchor Clamp Or Dead End Clamp Suitable For Ht Abc 96 Suspension Clamp Suitable For Ht Abc 97 Stainless Steel Strap 98 Stainless Steel Buckles 99 Cable Ties Uv Plastic Heavy Duty Around 250Mm Long 100 Supply Of Insulated Piercing Connector 101 40 Mm Dia., 3000 Mm Longclass B Gi Pipe Earth Electrode , Withaccessories Complete 102 6Kg 10 Inch Pvc Pipe Of Length 30 Cm Withpvc End Cap 103 Earth / Groundenhancementmaterial 104 Lt Coil For Earthing ( 50Mm Dia, 115 Turns ) As Per Specification 105 Earthing Spike Made Of 12.5Mm Dia; 3000Mm Long Solid Low Carbon Copper Bonded Ms Solid Grounding Rod Treated With Derivatives To Prevent Oxidation Of Copper Bonding Along With Fittings 106 Lightning Arrestor 107 9 Kv, 5 Ka, Distribution Class La 108 9 Kv, 10 Ka, Station Class La 109 Galvanized Stay Set With Anchor Plate Size 300X300x 10 Mm, 50 / 8Mm Stay Clamp, Guy Insulators 2Nos, Nuts, Bolts, Stay Tightners / Turn Buckle, 1.8 M Long 20 Mm Dia Solid Gs Stay Rod And 7 / 3.15Mm Dia Gi Stranted Wire As Per Technical Specifications Approved Works And As Per Drawing. 110 Galvanizedstay Set With Gi Stay Wire ( 7 / 4.00 Mm Dia ) For 33 Kv Poles, With Stay Wire, Guy Stay Insulator ( 2 Nos. ) , Guy Grip, Thimble 20Mm Dia Ht Stay Rod, Stay Anchor Plate Of Size 300 X 300 X 10 Mm 111 Rdss Sign Board As Per Specifications 112 New Pvc Alweather Proof Cable For Service Connection 113 2 C 2.5 Sqmm 114 4 C 16 Sqmm 115 4 C 25 Sqmm 116 12Kv 400Amps , 25Ka For 3 Sec , 3Phase, 3Pin Type Horizontal Mounting Type Gang Operated Ab Switch Along With Support Insulators Base Channel Down Pipe Arcing Horns Etcs Complete As Per Technical Specifitions. 117 Fuse Unit With Base 100 A 118 Gi Strip 25 X 3Mm, Gi Strip 25 X 6 Mm, 8 Swg Gi Wire, 6 Swg Gi Wire Etc 119 Pre-Fabricated Gi Channel Cross Arm, Bracket, Clamps, Galvanised Nuts, Bolts With Spring Washers Etc As Per Technical Specification, 120 11Kv 45 Kn, Polymeric Disc Insulators With Hardware Fittings 121 11Kv Polymeric Pin Insulator With Gi Pin 122 Boq - 5 -Lt Reconductoring Using Abc 123 Supply Of Poles As Per Specification And Scope Of Work 124 8 M Long / 380 Kgs Psc Poles 125 9 Meter Long / 487 Kg Psc Poles 126 A Type Pole, 10M - Vertical Member Isa 90X90x8mm;O / O Spacing 90Mm At Top & 350Mm At Bottom; Horizontal Ties Isa 50X50x6mm; Bottom Support Horizontal Ties- 500 Mm 127 9.1 M Long Steel Tubular Poles With Welded Steel Base Plate Of Designation 540 Sp 52 ( Is 2713, Pt I, Ii, Iii 1980 ) 128 Pscc Spun Pole 8.5M ( Structural Concrete M25 ( 1:1:2 ) , As Per Is 13158 ; 1.5M Below Gl, Pcc In A Pit 2M X 0.6M M20 ( 1:2:4 ) 129 Supply Of Lt Abc As Per Technical Specification And Scope Of Work. 130 3X95+1X70+1X16sqmm ( Insulated Messenger ) 131 3X70+1X50+1X16sqmm ( Insulated Messenger ) 132 2X50sqmm ( Insulated Messenger ) 133 Supply Of Abc Accessories 134 Abc To Abc T Connector 135 Abc To Abc Mid Span Joint ( Straight Joint ) 136 Satellite Connectors For Multiple Service Connection. 137 Ipc For Service Connection 138 Ipc For Abc To Db Connection 139 Ipc For Abc To Bare Conductor 140 Lt Distribution Box Suitablefor Single Phase And Three Phase Service Connection 141 Heat Shrinkable Tube 142 End Cap As Per Cable Size 143 Anchor Clamp Or Dead End Clamp Suitable For Lt Abc 144 Suspension Clamp Suitable For Lt Abc 145 Stainless Steel Strap 146 Stainless Steel Buckles 147 Cable Ties Uv Plastic Heavy Duty Around 250Mm Long 148 Bimetal Crimp Lug As Per The Cable Size 149 Nut & Bolt For Lug M12x40mm Brass 150 Earthingarrangement For Lt Line As Per Technical Specifications And Scope Of Work 151 Lt Coil For Earthing ( 50Mm Dia, 115 Turns ) As Per Specification 152 Earthing Spike Made Of 12.5Mm Dia; 3000Mm Long Solid Low Carbon Copper Bonded Ms Solid Grounding Rod Treated With Derivatives To Prevent Oxidation Of Copper Bonding Along With Fittings 153 40 Mm Dia., 3000 Mm Longclass B Gi Pipe Earth Electrode , Withaccessories Complete 154 6Kg 10 Inch Pvc Pipe Of Length 30 Cm Withpvc End Cap 155 Earth / Groundenhancementmaterial 156 Supply Of Lt Stay Set Complete With Anchor Plate ( 300X300x10mm ) , 50 / 8Mm Stay Clamp, Stay Insulator, Stay Tightner, Bolt And Nut, 1.8M Long 16Mm Dia Solid Gi Stay Rod And 7 / 3.15Mm Dia Gi Wire As Per Specification And Scope Of Work 157 3.5Cx25sqmm Xlpealuminium Cable 158 25 Sqmmxlpe Insulated Single Core Cable For Connecting To Distribution Box 159 Rdss Sign Board As Per Specifications 160 70 Sqmm 1 C Xlpe Cable 161 Fuse Unit Withbackalite / Frp Base 162 63 A 163 100 A 164 200 A 165 New Pvc Alweather Proof Cable For Service Connection 166 2 C 2.5 Sqmm 167 4 C 16 Sqmm 168 4 C 25 Sqmm 169 Boq - 6 - Installation Ofnew Lt Abc Of Sizes 3X95+1X70+1X16sqmm ( Insulated Messenger ) And 3X70+1X16sqmm ( Insulated Messenger ) 170 Supply Of Supporting Poles For Constructing New Lt Abc Lines 171 8 M Long / 380 Kgs Psc Poles 172 9 Meter Long / 487 Kg Psc Poles 173 A Type Pole, 10M - Vertical Member Isa 90X90x8mm;O / O Spacing 90Mm At Top & 350Mm At Bottom; Horizontal Ties Isa 50X50x6mm; Bottom Support Horizontal Ties- 500 Mm 174 Supply Of Lt Abc As Per Technical Specification And Scope Of Work. 175 3X95+1X70+1X16sqmm ( Insulated Messenger ) 176 3X70+1X50+1X16sqmm ( Insulated Messenger ) 177 Supply Of Abc Accessories 178 Abc To Abc T Connector 179 Abc To Abc Mid Span Joint ( Straight Joint ) 180 Satellite Connectors For Multiple Service Connection. 181 Ipc For Service Connector 182 Ipc For Abc To Db Connection 183 Ipc For Abc To Bare Conductor ( Two-Bolted ) 184 Lt Distribution Boxsuitable For Single Phase And Three Phase Service Connection 185 Heat Shrinkable Tube 186 Anchor Clamp Or Dead End Clamp Suitable For Lt Abc 187 End Cap As Per The Cable Size 188 Suspension Clamp Suitable For Lt Abc 189 Stainless Steel Strap 190 Stainless Steel Buckles 191 Cable Ties Uv Plastic Heavy Duty Around 250Mm Long 192 Bimetal Crimp Lug As Pe The Cable Size 193 Nut & Bolt For Lug M12x40mm Brass 194 Lt Coil For Earthing ( 50Mm Dia, 115 Turns ) As Per Specification 195 40 Mm Dia., 3000 Mm Longclass B Gi Pipe Earth Electrode , Withaccessories Complete 196 Earthing Spike Made Of 12.5Mm Dia; 3000Mm Long Solid Low Carbon Copper Bonded Ms Solid Grounding Rod Treated With Derivatives To Prevent Oxidation Of Copper Bonding Along With Fittings 197 6Kg 10 Inch Pvc Pipe Of Length 30 Cm Withpvc End Cap 198 Earth / Groundenhancementmaterial 199 Supply Of Lt Stay Set Complete With Anchor Plate ( 300X300x10mm ) , 50 / 8Mm Stay Clamps, Stay Insulator, Stay Tightner, Bolt And Nut, 1.8M Long 16 Mm Dia Solid Gi Stay Rod And 7 / 3.15Mm Dia Gi Wire As Per Specification And Scope Of Work 200 3.5 C 25 Sqmm Unarmoured Xlpecable For Connecting Ipc To Distribution Box 201 25 Sqmmxlpe Insulated Single Core Cable For Connecting To Distribution Box 202 Rdss Sign Board As Per Specifications 203 70 Sqmm 1 C Xlpe Cable 204 100 A 205 200 A 206 Boq - 7- Single Phase To Three Phase Conversion Using Abc 207 Supply Of Poles As Per Specification And Scope Of Work 208 8 M Long / 380 Kgs Psc Poles 209 9 Meter Long / 487 Kg Psc Poles 210 A Type Pole, 10M - Vertical Member Isa 90X90x8mm;O / O Spacing 90Mm At Top & 350Mm At Bottom; Horizontal Ties Isa 50X50x6mm; Bottom Support Horizontal Ties- 500 Mm 211 Supply Of Lt Abc As Per Technical Specification And Scope Of Work. 212 3X95+1X70+1X16sqmm ( Insulated Messenger ) 213 3X70+1X50+1X16sqmm ( Insulated Messenger ) 214 Supply Of Abc Accessories 215 Abc To Abc T Connector 216 Abc To Abc Mid Span Joint ( Straight Joint ) 217 Satellite Connectors For Multiple Service Connection. 218 Ipc For Service Connection 219 Ipc For Abc To Db Connection 220 Ipc For Abc To Bare Conductor 221 Lt Distribution Box Suitablefor Single Phase And Three Phase Service Connection 222 Heat Shrinkable Tube 223 End Cap As Per Cable Size 224 Anchor Clamp Or Dead End Clamp Suitable For Lt Abc 225 Suspension Clamp Suitable For Lt Abc 226 Stainless Steel Strap 227 Stainless Steel Buckles 228 Cable Ties Uv Plastic Heavy Duty Around 250Mm Long 229 Bimetal Crimp Lug As Per The Cable Size 230 Nut & Bolt For Lug M12x40mm Brass 231 Earthingarrangement For Lt Line As Per Technical Specifications And Scope Of Work 232 Lt Coil For Earthing ( 50Mm Dia, 115 Turns ) As Per Specification 233 40 Mm Dia., 3000 Mm Longclass B Gi Pipe Earth Electrode , Withaccessories Complete 234 6Kg 10 Inch Pvc Pipe Of Length 30 Cm Withpvc End Cap 235 Earth / Groundenhancementmaterial 236 Supply Of Lt Stay Set Complete With Anchor Plate ( 300X300x10mm ) , 50 / 8Mm Stay Clamp, Stay Insulator, Stay Tightner, Bolt And Nut, 1.8M Long 16Mm Dia Solid Gi Stay Rod And 7 / 3.15Mm Dia Gi Wire As Per Specification And Scope Of Work 237 3.5Cx25sqmm Xlpealuminium Cable 238 25 Sqmmxlpe Insulated Single Core Cable For Connecting To Distribution Box 239 Rdss Sign Board As Per Specifications 240 70 Sqmm 1 C Xlpe Cable 241 Fuse Unit Withbackalite / Frp Base 242 63 A 243 100 A 244 200 A 245 New Pvc Alweather Proof Cable For Service Connection 246 2 C 2.5 Sqmm 247 4 C 16 Sqmm 248 4 C 25 Sqmm 249 Boq -8- Single Phase To Three Phase Conversion Bare Oh 250 Supply Of Poles As Per Specification And Scope Of Work 251 8 M Long / 380 Kgs Psc Poles 252 9 Meter Long / 487 Kg Psc Poles 253 Prefabricated Items Likes 2 Line Cross Arm, 4 Line Cross Arms, Clamps, Gi Wire, Bolt And Nut, Washers Etc As Per Specifications And Scope Of Work. 254 Supply Of Lt Stay Set Complete With Anchor Plate ( 300X300x10mm ) , 50 / 8Mm Stay Clamps, Stay Insulator, Stay Tightner, Bolt And Nut, 1.8M Long 16Mm Dia Solid Gi Stay Rod And 7 / 3.15Mm Diagi Wire, Thimble & Guy Grip ( Black Colour ) As Per Specification And Scope Of Work 255 Lt Insulators And Hardware Fittings As Per Specification And Scope Of Work 256 Lt Shackles Set 257 Ltpin Insulator With Gi Pin 258 Earth Knobfor Neutral Line And Providing Earth 259 Aluminium Parallel Groove Clamp 260 Aluminium Bail Clamp 261 Dead-End Rabbit 262 Earthingarrangement For Lt Line As Per Technical Specifications And Scope Of Work 263 Lt Coil For Earthing ( 50Mm Dia, 115 Turns ) As Per Specification 264 40 Mm Dia., 3000 Mm Longclass B Gi Pipe Earth Electrode , Withaccessories Complete 265 6Kg 10 Inch Pvc Pipe Of Length 30 Cm Withpvc End Cap 266 Earth / Groundenhancementmaterial 267 Acsr Conductor With Following Sizes For Oh And Jumpers With Binding Materials Etc. 268 Acsr Rabbit 269 Line Spacers 270 300Mm 271 450Mm 272 Rdss Sign Board As Per Specifications 273 Fuse Unit Withbackalite / Frp Base 274 63 A 275 100 A 276 200 A 277 New Pvc Alweather Proof Cable For Service Connection 278 2 C 2.5 Sqmm 279 4 C 16 Sqmm 280 4 C 25 Sqmm 281 Boq - 9- Installation Of New Distribution Transformer Of Capacities 100, 160, 250, 315 And 500 Kva 282 Dtr Substation Supports As Per Technical Specification, Approved Drawings And Scope Of Work 283 Psc Pole 9M- / 487 Kg 284 A Pole - 10 M- Vertical Member Isa 90X90x8mm;O / O Spacing 90Mm At Top & 350Mm At Bottom; Horizontal Ties Isa 50X50x6mm; Bottom Support Horizontal Ties- 500 Mm 285 A Poles 11 M---Do -- Horizontal Ties Isa 50X50x6mm; 286 Prefabricated Items Likes V Cross Arm, Pole Top Bracket, Channel Cross Arm ( 3M, 2.4M ) , Clamps, 2 Line / 4 Line Cross Arm, Cross Bracings, Guarding Channels, Ms Flat Of Given Sizes, Gi Wire, Gi Strip 25 X 3Mm , Gi Strip 25 X 6Mm Etc As Per Specifications And Scope Of Work 287 Bolts & Nuts & Washers Of Various Sizes With Stud 288 12Kv, 400Amps , 25Ka For 3 Sec , 3Phase, 3Pin Type Horizontal Mounting Type Gang Operated Ab Switch Along With Support Insulators Base Channel Down Pipe Arcing Horns Etcs Complete As Per Technical Specifitions. 289 Stay Set ( Galvanized ) With 50X8mm Stay Clamp, Stay Insulator ( 2 Nos ) , Anchor Plate ( 300X 300X 10 Mm ) , Nuts &Bolts, Stay Tightner / Turn Buckle, Stay Rod ( 1.8M Long, 20 Mm Dia ) , 7 / 3.15 Mmdia Gi Stranded As Per Spec And Scope Of Work. 290 11 Kv Disc Insulator With Ms Cleat And Harware Fittings 291 11 Kv Pin Insulator With Gi Pin 292 Do Fuse Unit With Support Insulators 293 Earthing Arrangement 294 40 Mm Dia., 3000 Mm Longclass B Gi Pipe Earth Electrode , Withaccessories Complete 295 6Kg 10Inch Pvc Pipe Of Length 30Cm With Pvc End Cap 296 Earth / Groundenhancementmaterial 297 Earthing Spike Made Of 12.5Mm Dia; 3000Mm Long Solid Low Carbon Copper Bonded Ms Solid Grounding Rod Treated With Derivatives To Prevent Oxidation Of Copper Bonding Along With Fittings 298 Lightning Arrestor 299 Distribution Class Lightning Arrestor 9 Kv, 5 Ka 300 Station Class Lightning Arrestor 9 Kv, 10 Ka 301 Acsr Conductor Raccoon For Providing Drops And Jumper Connections 302 Acsr Conductor Rabbit For Providing Ltconnections 303 1.1 Kv Xlpe Insulated Unarmoured Cable For Connection Of Transformer Lv Side To Distribution Box And Distribution Box To Over Head Line As Perspec 304 1X 95 Sqmm Al Conductor Cable 305 1X 120 Sqmm Al Conductor Cable 306 Aluminium Socket 307 New Distribution Transformer ( Level 1 ) With All Accessories As Per Spec 308 11Kv / 433 V 100 Kva Distribution Transformer With All Accessories As Per Spec 309 Lt Distribution Box Made Of Ms Sheet Of Thickness Not Less Than 18 Swg Crca Sheet By Deep Drawn Method, Earthing Bus, Earthing Terminalfront Door Operate With Fuse Units & Proper Locking Arrangement As Per Tech.Spec 310 3 Pahse 100 Kva 2 / 3 Way Distribution Box 311 Dtr Metering 312 Smc Dtr Box 313 Lt Ct, 415 V, - / 5A, 5 Va, Class 0.5, 200 / 5, 10Va 314 Dtr Meter, 3X240v, - / 5A, Dtr Meter Of Accuracy Class 0.5S 315 Statutory Boards 316 Rdss Sign Board As Per Specifications 317 Lt Insulators And Hardware Fittings As Per Specification And Scope Of Work 318 Lt Shackles Set 319 Ltpin Insulator With Gi Pin 320 Earth Knobfor Neutral Line And Providing Earth 321 Aluminium Parallel Groove Clamp 322 Aluminium Bail Clamp 323 Dead-End Rabbit 324 Boq-10-Enhancement Ofdistribution Transformer 325 Dtr Substation Supports As Per Technical Specification, Approved Drawings And Scope Of Work 326 Psc Pole 9M- / 487 Kg 327 A Pole - 10 M- Vertical Member Isa 90X90x8mm;O / O Spacing 90Mm At Top & 350Mm At Bottom; Horizontal Ties Isa 50X50x6mm; Bottom Support Horizontal Ties- 500 Mm 328 A Poles 11 M---Do -- Horizontal Ties Isa 50X50x6mm; 329 Prefabricated Items Likes V Cross Arm, Pole Top Bracket, Channel Cross Arm ( 3M, 2.4M ) , Clamps, 2 Line / 4 Line Cross Arm, Cross Bracings, Guarding Channels, Ms Flat Of Given Sizes, Gi Wire, Gi Strip 25 X 3Mm , Gi Strip 25 X 6Mm Etc As Per Specifications And Scope Of Work 330 Bolts & Nuts & Washers Of Various Sizes With Stud 331 12Kv, 400Amps , 25Ka For 3 Sec , 3Phase, 3Pin Type Horizontal Mounting Type Gang Operated Ab Switch Along With Support Insulators Base Channel Down Pipe Arcing Horns Etcs Complete As Per Technical Specifitions. 332 Stay Set ( Galvanized ) With 50X8mm Stay Clamp, Stay Insulator ( 2 Nos ) , Anchor Plate ( 300X 300X 10 Mm ) , Nuts &Bolts, Stay Tightner / Turn Buckle, Stay Rod ( 1.8M Long, 20 Mm Dia ) , 7 / 3.15 Mmdia Gi Stranded As Per Spec And Scope Of Work. 333 Polymerinsulators With Hardware Fittings, Hardware Etc 334 11 Kv Disc Insulator With Ms Cleat And Harware Fittings 335 11 Kv Pin Insulator With Gi Pin 336 Do Fuse Unit With Support Insulators 337 Earthing Arrangement 338 40 Mm Dia., 3000 Mm Longclass B Gi Pipe Earth Electrode , Withaccessories Complete 339 6Kg 10 Inch Pvc Pipe Of Length 30 Cm Withpvc End Cap 340 Earth / Groundenhancementmaterial 341 Earthing Spike Made Of 12.5Mm Dia; 3000Mm Long Solid Low Carbon Copper Bonded Ms Solid Grounding Rod Treated With Derivatives To Prevent Oxidation Of Copper Bonding Along With Fittings 342 Lightning Arrestor 343 Distribution Class Lightning Arrestor 9 Kv, 5 Ka 344 Station Class Lightning Arrestor 9 Kv, 10 Ka 345 Acsr Conductor Raccoon For Providing Drops And Jumper Connections 346 Acsr Conductor Rabbit For Providing Ltconnections 347 1.1 Kv Xlpe Insulated Unarmoured Cable For Connection Of Transformer Lv Side To Distribution Box And Distribution Box To Over Head Line As Perspec 348 1X 120 Sqmm Al Conductor Cable 349 1X185 Sqmm Al Conductor Cable 350 Aluminium Socket 351 New Distribution Transformer ( Level 1 ) With All Accessories As Per Spec 352 11Kv / 433 V 100 Kva Distribution Transformer With All Accessories As Per Spec 353 11Kv / 433 V 160 Kva Distribution Transformer With All Accessories As Per Spec 354 11Kv / 433 V250kva Distribution Transformer With All Accessories As Per Spec 355 3 Pahse 100 Kva 2 / 3 Way Distribution Box 356 3 Phase 160 Kva 3 Waydistribution Box 357 3 Phase 250 Kva 3 Way Distribution Box 358 Dtr Metering 359 Smc Dtr Box 360 Lt Ct, 415 V, - / 5A, 5 Va, Class 0.5, 200 / 5 361 Lt Ct, 415 V, - / 5A, 5 Va, Class 0.5, 400 / 5 362 Lt Ct, 415 V, - / 5A, 5 Va, Class 0.5, 300 / 5 363 Lt Ct, 415 V, - / 5A, 5 Va, Class 0.5, 600 / 5 364 Dtr Meter, 3X240v, - / 5A, Dtr Meter Of Accuracy Class 0.5S 365 Statutory Boards 366 Rdss Sign Board As Per Specifications 367 Lt Insulators And Hardware Fittings As Per Specification And Scope Of Work 368 Lt Shackles Set 369 Earth Knobfor Neutral Line And Providing Earth 370 Aluminium Parallel Groove Clamp 371 Aluminium Bail Clamp 372 Dead-End Rabbit

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 31-Jan-2023 Corrigendum5 Technical Bid 02-02-2023

Key Value

Document Fees
INR 17700 /-
EMD
INR 35800000.0 /-
Tender Value
INR 178.87 Crore /-

BOQ Items

Name of Work: DEVELOPMENT OF DISTRIBUTION INFRASTRUCTURE AT KOZHIKODE DISTRICT (Electrical Circle,Kozhikode and Electrical Circle, Vadakara) of KERALA STATE UNDER REVAMPED REFORMS-BASED AND RESULTS-LINKED, DISTRIBUTION SECTOR SCHEME (RDSS)- (Schedule of rates and prices) - EX-WORKS SUPPLY OF MATERIALS
Sl. No. Item Description
1BOQ - 1 -11 KV line using 3 x 300 sq mm XLPE UG Cable
2Supply of 11 KV UG Cable of size 3x 300 sqmm
3HDPE PipePN 6 configuration and PE grade 80
4110 mm
5150mm
6160 mm
7Class B4.8 mm thick GI pipe
8150 mm
9Heat shrinkable Cable End Termination Kit suitable for 3 x 300 sqmm UG Cable
10Outdoor Type
11Heat shrinkable Straight joints using Shear Bolt Type as per IS 13573 Part II 2011 with dual wall and single triple extruded hybrid tubing with shear bolt connector as per IEC 61238, of rating 300/400 A
12Poles for the construction of DPs/ Cut pole
13PSC Poles 9M- 487 Kg
14Galvanized A Poles 11 M ( Hot dip Galvanized)
15Prefabricated materials like cross arms, clamps,bolts and nuts, GI Wire of size6 SWG, GI Strip of size 25 x 3mm etc
1640 mm dia., 3000 mm longclass B GI pipe earth electrode ,withaccessories complete
176Kg 10 inch PVC pipe of length 30 cm withPVC end cap
18Earth/ Groundenhancementmaterial
19Properly cured Reinforced Concrete Slabs of size 40 x 30 x 5 cm , 1 : 1.5 : 3cement concrete with6mm baby metal using 6 mm TMT at 10 cm c/c -with markings as specified
20Cable Route Markeras per specification
21Station Classpolymer type LA, 9 KV, 10 KA with all accessories
2212KV, 400amps ,25KA for 3 sec ,3phase,3pin type horizontal mounting type gang operated AB switch along with support insulators base channel down pipe arcing horns etcs complete as per technical specifitions.
23RDSS sign Board as per specifications
24Hot dip Galvanized stay set with anchor plate size 300x300x10mm, 50/8mm stay clamp, stay insulators 2nos,nuts, bolts, stay tightners/Turn Buckle, 1.8 M long 20mm Dia solid GI stay rod and 7/3.15mm dia GI stranted wire as per technical specifications approved works and as per drawing.
25BOQ-2 - 11 kV Aerial Bunched Cables
26POLES for 11 KV ABCline as per technical specifications approved works and as per drawing.
27PSC pole 9M- /487 kg
28A pole - 10 m- Vertical member ISA 90x90x8mm;O/o spacing 90mm at top & 350mm at bottom; Horizontal ties ISA 50x50x6mm; bottom support horizontal ties- 500 mm
29A Poles 11 M---do -- Horizontal ties ISA 50x50x6mm;
30A pole 12 M-- do - Horizontal ties ISA 65x65x6mm;
31A pole 14 m 14m Vertical member ISA 100x100x8mm -- diagonal tie 50x50x8mm; Horizontal ties ISA 65x65x6mm;bottom support horizontal ties- 580 mm
32PSCC Spun Pole 9.5m (Structural concrete M25(1:1:2), 700 kg as per IS 13158; 1.5m below GL, PCC in a pit 2m x 0.6m M15(1:2:4) 20 mm size stone aggregate chips
33Four legged Pole
34Supply of 11KV ABC as per technical specification and scope of work.
353x120+1x95sqmm(insulated messenger)
36Single core removable and re usable TEE for 11kV ABC (MVT) (Set of 3nos)
37Special channel cross arm for fixing the MVT, LA with bolt and nuts, Earthwire etc.
3811KV end termination kits
39suitable for 120sqmm
40ABC accessories
41Heat shrinkable tube
42Anchor clamp or dead end clamp suitable for HT ABC
43Suspension clamp suitable for HT ABC
44Stainless steel strap
45Stainless steel buckles
46Cable ties UV plastic heavy duty around 250mm long
47Ligthning Arrester
489KV 5KAmps polymeric surge arrester Distribution classs(3nos per set)
499KV 10KAmps polymeric surge arrester Station classs(3nos per set)
5040 mm dia., 3000 mm longclass B GI pipe earth electrode ,withaccessories complete
516Kg 10 inch PVC pipe of length 30 cm withPVC end cap
52Earth/ Groundenhancementmaterial
53Earthing spike made of 12.5mm dia; 3000mm long solid low carbon Copper Bonded MS solid Grounding Rod treated with derivatives to prevent oxidation of copper bonding along with fittings
54LT Coil for Earthing (50mm dia, 115 turns) as per specification
55Galvanized stay set with anchor plate size 300x300x10mm, 50/8mm stay clamp, guy insulators 2nos,nuts, bolts, stay tightners/Turn Buckle, 1.8 M long 20mm Dia solid GI stay rod and 7/3.15mm dia GI stranded wire as per technical specifications ,scope of works and as per drawing.
56RDSS sign Board as per specifications
57Pre-fabricated GI Channel cross arm, bracket, clamps, Galvanised Nuts, Bolts with spring washers etc as per technical specification,
5811kV 45 KN, polymeric disc insulators with hardware fittings
5911kV polymeric pin insulator with GI pin
6012KV 400amps ,25KA for 3 sec ,3phase,3pin type horizontal mounting type gang operated AB switch along with support insulators base channel down pipe arcing horns etcs complete as per technical specifitions.
61BOQ - 3 - 11 kV Reconductoring using bare OH ACSR
62SUPPORT POLE for 11 KV OH line as per technical specifications approved works and as per drawing.
63PSC pole 9M- /487 kg
64A Poles 11 M---do -- Horizontal ties ISA 50x50x6mm;
65Prefabricated Items likes V cross arm(10.75kg/each), Pole top F clamp(1.5kg/each), Double C cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, including back clamp, etc made of GI Channels,angle, flats of given sizes for over head structures, GI Strip 25 x 3mm, GI Strip 25 x 6 mm, 8 SWG GI wire, 6 SWG GI wire etc as per technical specification, approved drawings and scope of work.
66MS bolts and nuts with washers and stud
67Galvanized stay set with anchor plate size 300x300x 10 mm, 50/8mm stay clamp, guy insulators 2nos,nuts, bolts, stay tightners/Turn Buckle, 1.8 M long 20 mm Dia solid GS stay rod and 7/3.15mm dia GI stranted wire as per technical specifications approved works and as per drawing.
68Polymeric insulator with accesoeries
6911kV 45 KN, polymeric disc insulators with hardware fittings
7011kV polymeric pin insulator with GI pin
7140 mm dia., 3000 mm longclass B GI pipe earth electrode ,withaccessories complete
726Kg 10 inch PVC pipe of length 30 cm withPVC end cap
73Earth/ Groundenhancementmaterial
74LT Coil for Earthing (50mm dia, 115 turns) as per specification
75ACSR Conductor with following types
76ASCR Racoon
77RDSS sign Board as per specifications
78BOQ4 - Reconductoring 11kV lines withABC
79POLES for 11 KV ABCline as per technical specifications approved works and as per drawing.
80PSC pole 9M- /487 kg
81A pole - 10 m- Vertical member ISA 90x90x8mm;O/o spacing 90mm at top & 350mm at bottom; Horizontal ties ISA 50x50x6mm; bottom support horizontal ties- 500 mm
82A Poles 11 M---do -- Horizontal ties ISA 50x50x6mm;
83A pole 12 M-- do - Horizontal ties ISA 65x65x6mm;
84A pole 13 m -- do - Horizontal ties ISA 65x65x6mm;
85Supply of 11KV ABC as per technical specification and scope of work.
863x150+1x120sqmm(insulated messenger)
873x120+1x95sqmm(insulated messenger)
88Single core removable and re usable TEE for 11kv ABC (MVT) (Set of 3nos)
89Special channel cross arm for fixing the MVT, LA with bolt and nuts, Earthwire etc.
9011KV end termination kits for 3phase
91suitable for 150sqmm
92suitable for 120sqmm
93ABC Accessories
94Heat shrinkable tube
95Anchor clamp or dead end clamp suitable for HT ABC
96Suspension clamp suitable for HT ABC
97Stainless steel strap
98stainless steel buckles
99Cable ties UV plastic heavy duty around 250mm long
100supply of Insulated Piercing Connector
10140 mm dia., 3000 mm longclass B GI pipe earth electrode ,withaccessories complete
1026Kg 10 inch PVC pipe of length 30 cm withPVC end cap
103Earth/ Groundenhancementmaterial
104LT Coil for Earthing (50mm dia, 115 turns) as per specification
105Earthing spike made of 12.5mm dia; 3000mm long solid low carbon Copper Bonded MS solid Grounding Rod treated with derivatives to prevent oxidation of copper bonding along with fittings
106Lightning Arrestor
1079 KV, 5 KA, Distribution Class LA
1089 KV, 10 KA, Station Class LA
109Galvanized stay set with anchor plate size 300x300x 10 mm, 50/8mm stay clamp, guy insulators 2nos,nuts, bolts, stay tightners/Turn Buckle, 1.8 M long 20 mm Dia solid GS stay rod and 7/3.15mm dia GI stranted wire as per technical specifications approved works and as per drawing.
110Galvanizedstay set with GI stay wire (7/4.00 mm dia) for 33 kV Poles,with stay wire,Guy stay insulator (2 Nos.),Guy Grip, Thimble 20mm dia HT stay rod, Stay Anchor Plate of size 300 x 300 x 10 mm
111RDSS sign Board as per specifications
112New PVC Alweather proof cable for service connection
1132 C 2.5 sqmm
1144 C 16 sqmm
1154 C 25 sqmm
11612KV 400amps ,25KA for 3 sec ,3phase,3pin type horizontal mounting type gang operated AB switch along with support insulators base channel down pipe arcing horns etcs complete as per technical specifitions.
117Fuse unit with base 100 A
118GI Strip 25 x 3mm, GI Strip 25 x 6 mm, 8 SWG GI wire, 6 SWG GI wire etc
119Pre-fabricated GI Channel cross arm, bracket, clamps, Galvanised Nuts, Bolts with spring washers etc as per technical specification,
12011kV 45 KN, polymeric disc insulators with hardware fittings
12111kV polymeric pin insulator with GI pin
122BOQ - 5 -LT Reconductoring using ABC
123Supply of poles as per specification and scope of work
1248 m long /380 kgs PSC Poles
1259 meter long /487 KG PSC Poles
126A Type Pole, 10m - Vertical member ISA 90x90x8mm;O/o spacing 90mm at top & 350mm at bottom; Horizontal ties ISA 50x50x6mm; bottom support horizontal ties- 500 mm
1279.1 M long steel Tubular poles with welded steel base plate of Designation 540 SP 52 (IS 2713, Pt I, II, III 1980)
128PSCC Spun Pole 8.5m (Structural concrete M25(1:1:2), as per IS 13158 ; 1.5m below GL, PCC in a pit 2m x 0.6m M20(1:2:4)
129Supply of LT ABC as per technical specification and scope of work.
1303x95+1x70+1x16sqmm(insulated messenger)
1313x70+1x50+1x16sqmm(insulated messenger)
1322x50sqmm(insulated messenger)
133Supply of ABC accessories
134ABC to ABC T connector
135ABC to ABC Mid span joint (straight joint)
136Satellite connectors for multiple service connection.
137IPC for service connection
138IPC for ABC to DB connection
139IPC for ABC to bare conductor
140LT Distribution Box suitablefor single phase and three phase service connection
141Heat shrinkable tube
142End cap as per cable size
143Anchor clamp or dead end clamp suitable for LT ABC
144Suspension clamp suitable for LT ABC
145Stainless steel strap
146Stainless steel buckles
147Cable ties UV plastic heavy duty around 250mm long
148Bimetal crimp lug as per the cable size
149Nut & Bolt for LUG M12x40mm Brass
150Earthingarrangement for LT line as per technical specifications and scope of work
151LT Coil for Earthing (50mm dia, 115 turns) as per specification
152Earthing spike made of 12.5mm dia; 3000mm long solid low carbon Copper Bonded MS solid Grounding Rod treated with derivatives to prevent oxidation of copper bonding along with fittings
15340 mm dia., 3000 mm longclass B GI pipe earth electrode ,withaccessories complete
1546Kg 10 inch PVC pipe of length 30 cm withPVC end cap
155Earth/ Groundenhancementmaterial
156Supply of LT stay set complete with anchor plate(300x300x10mm), 50/8mm stay clamp, stay insulator, stay tightner,bolt and nut, 1.8m long 16mm dia solid GI stay rod and 7/3.15mm dia GI wire as per specification and scope of work
1573.5Cx25sqmm XLPEAluminium Cable
15825 sqmmXLPE insulated single core cable for connecting to Distribution Box
159RDSS Sign Board as per specifications
16070 sqmm 1 C XLPE cable
161Fuse unit withbackalite/ FRP base
16263 A
163100 A
164200 A
165New PVC Alweather proof cable for service connection
1662 C 2.5 sqmm
1674 C 16 sqmm
1684 C 25 sqmm
169BOQ - 6 - Installation ofnew LT ABC of sizes 3x95+1x70+1x16sqmm(insulated messenger)and 3x70+1x16sqmm(insulated messenger)
170Supply of supporting poles for constructing New LT ABC Lines
1718 m long /380 kgs PSC Poles
1729 meter long /487 KG PSC Poles
173A Type Pole, 10m - Vertical member ISA 90x90x8mm;O/o spacing 90mm at top & 350mm at bottom; Horizontal ties ISA 50x50x6mm; bottom support horizontal ties- 500 mm
174Supply of LT ABC as per technical specification and scope of work.
1753x95+1x70+1x16sqmm(insulated messenger)
1763x70+1x50+1x16sqmm(insulated messenger)
177Supply of ABC accessories
178ABC to ABC T Connector
179ABC to ABC Mid span joint(straight joint)
180Satellite connectors for multiple service connection.
181IPC for service connector
182IPC for ABC to DB connection
183IPC for ABC to bare conductor(two-bolted)
184LT distribution boxsuitable for single phase and three phase service connection
185Heat shrinkable tube
186Anchor clamp or dead end clamp suitable for LT ABC
187End cap as per the cable size
188Suspension clamp suitable for LT ABC
189Stainless steel strap
190Stainless steel buckles
191Cable ties UV plastic heavy duty around 250mm long
192Bimetal crimp lug as pe the cable size
193Nut & Bolt for LUG M12x40mm Brass
194LT Coil for Earthing (50mm dia, 115 turns) as per specification
19540 mm dia., 3000 mm longclass B GI pipe earth electrode ,withaccessories complete
196Earthing spike made of 12.5mm dia; 3000mm long solid low carbon Copper Bonded MS solid Grounding Rod treated with derivatives to prevent oxidation of copper bonding along with fittings
1976Kg 10 inch PVC pipe of length 30 cm withPVC end cap
198Earth/ Groundenhancementmaterial
199Supply of LT stay set complete with anchor plate(300x300x10mm), 50/8mm stay clamps, stay insulator, stay tightner,bolt and nut, 1.8m long 16 mm dia solid GI stay rod and 7/3.15mm dia GI wire as per specification and scope of work
2003.5 C 25 sqmm unarmoured XLPEcable for connecting IPC to Distribution Box
20125 sqmmXLPE insulated single core cable for connecting to Distribution Box
202RDSS sign Board as per specifications
20370 sqmm 1 C XLPE cable
204100 A
205200 A
206BOQ - 7- Single Phase to Three Phase Conversion using ABC
207Supply of poles as per specification and scope of work
2088 m long /380 kgs PSC Poles
2099 meter long /487 KG PSC Poles
210A Type Pole, 10m - Vertical member ISA 90x90x8mm;O/o spacing 90mm at top & 350mm at bottom; Horizontal ties ISA 50x50x6mm; bottom support horizontal ties- 500 mm
211Supply of LT ABC as per technical specification and scope of work.
2123x95+1x70+1x16sqmm(insulated messenger)
2133x70+1x50+1x16sqmm(insulated messenger)
214Supply of ABC accessories
215ABC to ABC T connector
216ABC to ABC Mid span joint (straight joint)
217Satellite connectors for multiple service connection.
218IPC for service connection
219IPC for ABC to DB connection
220IPC for ABC to bare conductor
221LT Distribution Box suitablefor single phase and three phase service connection
222Heat shrinkable tube
223End cap as per cable size
224Anchor clamp or dead end clamp suitable for LT ABC
225Suspension clamp suitable for LT ABC
226Stainless steel strap
227Stainless steel buckles
228Cable ties UV plastic heavy duty around 250mm long
229Bimetal crimp lug as per the cable size
230Nut & Bolt for LUG M12x40mm Brass
231Earthingarrangement for LT line as per technical specifications and scope of work
232LT Coil for Earthing (50mm dia, 115 turns) as per specification
23340 mm dia., 3000 mm longclass B GI pipe earth electrode ,withaccessories complete
2346Kg 10 inch PVC pipe of length 30 cm withPVC end cap
235Earth/ Groundenhancementmaterial
236Supply of LT stay set complete with anchor plate(300x300x10mm), 50/8mm stay clamp, stay insulator, stay tightner,bolt and nut, 1.8m long 16mm dia solid GI stay rod and 7/3.15mm dia GI wire as per specification and scope of work
2373.5Cx25sqmm XLPEAluminium Cable
23825 sqmmXLPE insulated single core cable for connecting to Distribution Box
239RDSS Sign Board as per specifications
24070 sqmm 1 C XLPE cable
241Fuse unit withbackalite/ FRP base
24263 A
243100 A
244200 A
245New PVC Alweather proof cable for service connection
2462 C 2.5 sqmm
2474 C 16 sqmm
2484 C 25 sqmm
249BOQ -8- Single Phase to Three Phase Conversion Bare OH
250Supply of poles as per specification and scope of work
2518 m long /380 kgs PSC Poles
2529 meter long /487 KG PSC Poles
253Prefabricated Items likes 2 line cross arm, 4 line cross arms, clamps, GI wire,bolt and nut, washers etc as per specifications and scope of work.
254Supply of LT stay set complete with anchor plate(300x300x10mm), 50/8mm stay clamps, stay insulator, stay tightner,bolt and nut, 1.8m long 16mm dia solid GI stay rod and 7/3.15mm diaGI wire,Thimble & Guy grip (Black colour) as per specification and scope of work
255LT Insulators and hardware fittings as per specification and scope of work
256LT shackles Set
257LTpin insulator with GI pin
258Earth Knobfor neutral line and providing earth
259Aluminium parallel groove clamp
260Aluminium bail clamp
261Dead-end Rabbit
262Earthingarrangement for LT line as per technical specifications and scope of work
263LT Coil for Earthing (50mm dia, 115 turns) as per specification
26440 mm dia., 3000 mm longclass B GI pipe earth electrode ,withaccessories complete
2656Kg 10 inch PVC pipe of length 30 cm withPVC end cap
266Earth/ Groundenhancementmaterial
267ACSR Conductor with following sizes for OH and jumpers with binding materials etc.
268ACSR Rabbit
269Line Spacers
270300mm
271450mm
272RDSS Sign Board as per specifications
273Fuse unit withbackalite/ FRP base
27463 A
275100 A
276200 A
277New PVC Alweather proof cable for service connection
2782 C 2.5 sqmm
2794 C 16 sqmm
2804 C 25 sqmm
281BOQ - 9- Installation of New Distribution Transformer of capacities 100, 160, 250, 315 and 500 KVA
282DTR Substation Supports as per technical specification, approved drawings and scope of work
283PSC pole 9M- /487 kg
284A pole - 10 m- Vertical member ISA 90x90x8mm;O/o spacing 90mm at top & 350mm at bottom; Horizontal ties ISA 50x50x6mm; bottom support horizontal ties- 500 mm
285A Poles 11 M---do -- Horizontal ties ISA 50x50x6mm;
286Prefabricated Items likes V cross arm, Pole top bracket, Channel cross arm (3M,2.4M), Clamps, 2 line/4 line cross arm, Cross bracings, Guarding channels, MS flat of given sizes, GI wire, GI strip 25 x 3mm , GI strip 25 x 6mm etc as per specifications and scope of work
287Bolts & Nuts & Washers of Various sizes with stud
28812KV, 400amps ,25KA for 3 sec ,3phase,3pin type horizontal mounting type gang operated AB switch along with support insulators base channel down pipe arcing horns etcs complete as per technical specifitions.
289Stay Set (Galvanized) with 50X8mm stay clamp, stay insulator (2 nos), Anchor plate (300x 300x 10 mm), Nuts &Bolts, Stay Tightner/Turn Buckle, Stay Rod (1.8m long, 20 mm dia),7/3.15 mmdia GI stranded as per spec and scope of work.
29011 KV Disc Insulator with MS Cleat and harware fittings
29111 KV Pin Insulator with GI pin
292DO Fuse Unit with support insulators
293Earthing arrangement
29440 mm dia., 3000 mm longclass B GI pipe earth electrode ,withaccessories complete
2956kg 10inch PVC pipe of length 30cm with PVC end cap
296Earth/ Groundenhancementmaterial
297Earthing spike made of 12.5mm dia; 3000mm long solid low carbon Copper Bonded MS solid Grounding Rod treated with derivatives to prevent oxidation of copper bonding along with fittings
298Lightning Arrestor
299Distribution class Lightning Arrestor 9 KV, 5 KA
300Station Class Lightning Arrestor 9 KV, 10 KA
301ACSR Conductor Raccoon for providing drops and jumper connections
302ACSR Conductor Rabbit for providing LTconnections
3031.1 KV XLPE insulated unarmoured cable for connection of transformer LV side to Distribution Box and Distribution Box to Over Head Line as per spec
3041x 95 sqmm Al conductor cable
3051x 120 sqmm Al conductor cable
306Aluminium socket
307New Distribution Transformer (Level 1) with all Accessories as per spec
30811KV/433 V 100 KVA Distribution Transformer with all Accessories as per spec
309LT Distribution Box made of MS sheet of thickness not less than 18 SWG CRCA sheet by deep drawn method, earthing bus, earthing terminal front door operate with Fuse units & proper locking arrangement as per tech.spec
3103 Pahse 100 KVA 2/3 way Distribution Box
311DTR Metering
312SMC DTR Box
313LT CT, 415 V, -/5A, 5 VA, Class 0.5, 200/5,10VA
314DTR Meter, 3x240V, -/5A, DTR Meter of accuracy class 0.5S
315Statutory Boards
316RDSS Sign Board as per specifications
317LT Insulators and hardware fittings as per specification and scope of work
318LT shackles Set
319LTpin insulator with GI pin
320Earth Knobfor neutral line and providing earth
321Aluminium parallel groove clamp
322Aluminium bail clamp
323Dead-end Rabbit
324BOQ-10-Enhancement ofDistribution Transformer
325DTR Substation Supports as per technical specification, approved drawings and scope of work
326PSC pole 9M- /487 kg
327A pole - 10 m- Vertical member ISA 90x90x8mm;O/o spacing 90mm at top & 350mm at bottom; Horizontal ties ISA 50x50x6mm; bottom support horizontal ties- 500 mm
328A Poles 11 M---do -- Horizontal ties ISA 50x50x6mm;
329Prefabricated Items likes V cross arm, Pole top bracket, Channel cross arm (3M,2.4M), Clamps, 2 line/4 line cross arm, Cross bracings, Guarding channels, MS flat of given sizes, GI wire, GI strip 25 x 3mm , GI strip 25 x 6mm etc as per specifications and scope of work
330Bolts & Nuts & Washers of Various sizes with stud
33112KV, 400amps ,25KA for 3 sec ,3phase,3pin type horizontal mounting type gang operated AB switch along with support insulators base channel down pipe arcing horns etcs complete as per technical specifitions.
332Stay Set (Galvanized) with 50X8mm stay clamp, stay insulator (2 nos), Anchor plate (300x 300x 10 mm), Nuts &Bolts, Stay Tightner/Turn Buckle, Stay Rod (1.8m long, 20 mm dia),7/3.15 mmdia GI stranded as per spec and scope of work.
333PolymerInsulators with hardware fittings, hardware etc
33411 KV Disc Insulator with MS Cleat and harware fittings
33511 KV Pin Insulator with GI pin
336DO Fuse Unit with support insulators
337Earthing arrangement
33840 mm dia., 3000 mm longclass B GI pipe earth electrode ,withaccessories complete
3396Kg 10 inch PVC pipe of length 30 cm withPVC end cap
340Earth/ Groundenhancementmaterial
341Earthing spike made of 12.5mm dia; 3000mm long solid low carbon Copper Bonded MS solid Grounding Rod treated with derivatives to prevent oxidation of copper bonding along with fittings
342Lightning Arrestor
343Distribution class Lightning Arrestor 9 KV, 5 KA
344Station Class Lightning Arrestor 9 KV, 10 KA
345ACSR Conductor Raccoon for providing drops and jumper connections
346ACSR Conductor Rabbit for providing LTconnections
3471.1 KV XLPE insulated unarmoured cable for connection of transformer LV side to Distribution Box and Distribution Box to Over Head Line as per spec
3481x 120 sqmm Al conductor cable
3491x185 sqmm Al conductor cable
350Aluminium socket
351New Distribution Transformer (Level 1) with all Accessories as per spec
35211KV/433 V 100 KVA Distribution Transformer with all Accessories as per spec
35311KV/433 V 160 KVA Distribution Transformer with all Accessories as per spec
35411KV/433 V250KVA Distribution Transformer with all Accessories as per spec
3553 Pahse 100 KVA 2/3 way Distribution Box
3563 Phase 160 KVA 3 wayDistribution Box
3573 Phase 250 KVA 3 way Distribution Box
358DTR Metering
359SMC DTR Box
360LT CT, 415 V, -/5A, 5 VA, Class 0.5, 200/5
361LT CT, 415 V, -/5A, 5 VA, Class 0.5, 400/5
362LT CT, 415 V, -/5A, 5 VA, Class 0.5, 300/5
363LT CT, 415 V, -/5A, 5 VA, Class 0.5,600/5
364DTR Meter, 3x240V, -/5A, DTR Meter of accuracy class 0.5S
365Statutory Boards
366RDSS Sign Board as per specifications
367LT Insulators and hardware fittings as per specification and scope of work
368LT shackles Set
369Earth Knobfor neutral line and providing earth
370Aluminium parallel groove clamp
371Aluminium bail clamp
372Dead-end Rabbit