Tender For Installation Of Sub Marsible Overhead Tank With Solar Panel Chapduar Fp School
Tender Value
3.49 Lakhs
Estimated cost
Bid Submission
30 Jan 2023
0 days left
EMD
6999
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
North Dinajpur → West Bengal
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Installation Of Sub Marsible Overhead Tank With Solar Panel Chapduar Fp School
BOQ
| Sl. No. | Item Description |
| 1 | [ Page-1, It No. -2.(a)] / Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete(a)Depth of excavation not exceeding 1,500 mm. |
| 2 | Item No.-1[Page-1, It No. -3.(a)]/ Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work)(a) With earth obtained from excavation of foundation. |
| 3 | Item No.-4[Page-2, It No. -4.(a)(A)/ Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity). |
| 4 | [ Page-14, It No. -01]/ Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand. |
| 5 | PAGE-24;ITEM-4/ Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes. a) Pakur Variety. |
| 6 | [P-26, It.-10.(i)]/ Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. i)Pakur Variety. |
| 7 | [P-44, It.-40]/ Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction (a) For works in foundation and upto roof of ground floor/upto 4 m.(i) Tor steel/ Mild Steel. II. Other than SAIL/TATA/RINL |
| 8 | Hire and Labour charge for Shuttering |
| 9 | [P-42, It.-36]/(a) 25 mm. to 30 mm. thick wooden shutteringas per decision & direction of Engineer-in-charge. |
| 10 | ( P-15, It.-7.)/ Brick work with 1st class bricks in cement mortar (1:4)(a) In foundation and plinth |
| 11 | ( P-16, It.-16.)/ 125mm. thick Brick work with 1st. class bricks in cement mortar (4:1) in ground floor. |
| 12 | PAGE-189;ITEM-1/ Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] i) with (6:1) cement mortor. c) 15 mm thick plaster |
| 13 | [ Page-64, It No. -35-B (a)-i]/ Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key,stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout aterials etc.A) Floor.With Sand Cement Mortar (1:4) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. (b) Area of each tile above 0.09 Sq.m.(ii) Other than Coloured decorative including white |
| 14 | With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. (a) Area of each tile upto 0.09 Sq.m(i) Coloured decorative |
| 15 | PAGE-192;ITEM-15 / Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc. NOTE:Cement 0.152 cu.m per100 sq.m. |
| 16 | PAGE-197;ITEM-15/ Applying decorative cement based paint of approved quality after preparing the surface including scraping the same thoroughly (plastered or concrete surface) as per manufacturer\"s specification .In Ground floor:(iii) Two coats. |
| 17 | PAGE-194;ITEM-1/ Applying decorative cement based paint of approved quality after preparing the surface including scraping the same thoroughly (plastered or concrete surface) as per manufacturer\"s specification.: In Ground floor: (c) Two coats. |
| 18 | PAGE-49:ITEM-1(C)/ Labour for boring tube well of required dia. by water jet system through any type of soil strata including hire and labour charges for boring pipes, scaffolding, tools and plants as necessary and taking out them and lowering pipes, strainers, blind pipe etc. and fitting and fixing the same complete including bucket washing and other incidental works in the connection. The tube well should have a minimum 50 mm gap in between the outside of the tubewell pipe and the bore (c) For depth upto 150 metre for 40 mm dia. Tube well with top enlargement of 100 mm dia. i) 100 mm dia boring etc. top enlargement |
| 19 | PAGE-49:ITEM-1(C)/ Labour for boring tube well of required dia. by water jet system through any type of soil strata including hire and labour charges for boring pipes, scaffolding, tools and plants as necessary and taking out them and lowering pipes, strainers, blind pipe etc. and fitting and fixing the same complete including bucket washing and other incidental works in the connection. The tube well should have a minimum 50 mm gap in between the outside of the tubewell pipe and the bore (c) For depth upto 150 metre for 40 mm dia. Tube well with top enlargement of 100 mm dia. ii)40 mm dia boring etc. |
| 20 | PAGE-52:ITEM-6(i)/ Supplying high density polythenestrainer of approved make with adopter conforming to I.S.12818 specifications. |
| 21 | PAGE-13:ITEM-19(iii)/ Supply of PVC pipes & fittings Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). 40 mm dia |
| 22 | PAGE-14:ITEM-19(iii ) Supply of PVC pipes & fittings Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I).80 mm dia. |
| 23 | PAGE-54:ITEM-18/ Supplying, fitting and fixing G.I. cap at top(i)100 mm dia |
| 24 | PAGE-55:ITEM-24/ Packing the annular space between the outside of the tube well pipes & strainers and the bore with pea size washed gravel of approved quality having size from 2 mm to 5 mm or the size approved by the Engineer-incharge including cost of all materials labour and equipment complete.Note: Initial 6 m. of Annular space between the housing pipe and the bore should not be shrouded with Pea size gravel to avoid contamination with surface water. |
| 25 | PAGE-12:ITEM-19(I)/ Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately)(a) For Exposed Work PVC Pipes i) 32mm dia |
| 26 | PAGE-12:ITEM-19(I)/ Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately)(a) For Exposed Work PVC Pipes ii) 25 mm dia |
| 27 | PAGE-7:ITEM-8 (a)/ Supplying, fitting and fixing push cock of heavy quality and of approved make and brand. (a) Cast iron (i) 15 mm |
| 28 | PAGE-30:ITEM-2(Q)/ Compact Ball Valve with SS Handle For CPVC/ UPVC Fittings. (As per ASTM D 2467, Schedule 80) 25 mm dia. |
| 29 | PAGE-18:ITEM-19(iii )(L)/ Reducing socket 100mm X 40mm dia |
| 30 | PAGE-37:ITEM-6/ Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer. (b) 1000 litre capacity |
| 31 | PWD SOR (S & P) Page No. 89, Item No. 4 (7th Corrigenda & Addenda for Schedule of rates PWD (WB) w.e.f 01.11.2017) / Construction of circular soak well 2.5 metre deep in all types of sandy soils with dry brick work upto 1.6 metre from the bottom having 150 mm ntermediate cement brick work (1:4) band all round and cement brick work (1:4) upto 0.90 metre from top with 20mm thick cement plastering (1:4) to inside face upto the depth of cement brick work, 15mm thick cement plaster (1:4) on outer face from top of the well upto G.L. and 6 mm thick cement plaster (1:4) on top of the R.C.C. cover slab including filling bottom 1.00 metre of inside of the well with brick metal (50 mm to 63 mm size) including R.C.C. cover slab of 100 mm thick with cement conc (1:1.5:3) with stone chips with necessary reinforcement and shuttering including one 560 mm dia. R.C.C. manhole cover (heavy type)of approved make supplied, fitted and fixed in the cover slab with necessary fittings, making nacessary arrangements for pipe connections, excavation of well including shoring, dewatering and removing the exess earth from the premises as per direction complete in all respect with all costs of labour and materials. With 250 mm thick dry brick work and 250 mm thick cement brick work (1:6) and 1.00m inside dia. For - JSW/ JSPL/ SHYAM/ SRMB/ BMASL/ ELECTRO STEEL/ SSL |
| 32 | Local Market Rate / Supply, delivery & installation 1.00 H.P. capacity D.C./ A.C. submerssible pump in the same bore (designed to use with Solar Power) of approved brand whose output is not less than 2000 Ltr/hours at 40 Mtr. head including supply of all necessary materials (Hanging pipe, Copper weir for supporting to hang the Submersible etc.) of approved quality, labour etc. with all allied works as per direction of the E.I.C. [D.C./ A.C. Submerssible Pump and controller should carry a warranty of 1 year directly from the manufacturers] |
| 33 | Local Market Rate / Supply, delivery & installation of 1000 watt (250*4) peak capacity Solar photovaltatic array Panels of approved brand on the structure as per standard & approved drawing which will grouted either ground based by construction of foundation concrete or integrated with the staging steel structure of water tank. The Solar Panels will then be connected to the Pump Controller which in turn will be connected to the pump as well as the level indicator of the water tank as per direction of the E.I.C. [Solar Panels will carriy a warranty (25 Years) as per attached technical specs] |
| 34 | Local Market Rate/ On-Off Auto Censer Device. |
| 35 | Local Market Rate/ Cable with Others (Mcb, Jack, Lace). |
| 36 | Local Market Rate/ Supplying fitting fixing 6mm 2 Core aluminium wire for Submersible Pump. |
| 37 | Local Market Rate/ Mounting GI Structure. |
| 38 | Local Market Rate/ Additional cost for connection & Wooden Box with Key fittings. |
| 39 | Local Market Rate/ Sypply and Installation of 7 Stage UV Purifier System with Iron Removal Unit. (Model - WAMAX, Capacity 300Ltr./ Hours). Specification - UV Purifier System with Iron Removal Unit)[1. Body Type - SS Box Pipe & MS stand 29\"x20\"\", 2. Pre Filter - 02 Nos 20\" x 2.5 \" 5 Micron PP Filter,3. Filter - GAC - 01 Nos CTO- 02 Nos, 4. 4 nos. Duel Media Filter - Sand and Active Carbon, 5. Vessel Size- 8\" x 44\" - 01 nos,6. UV system - 300 Ltr./ Hours 1 pcs,UV Make- Alfa, Flow- 300 Ltr./ Hours 7. The Iron Removal Unit (Dual Vessel) of approved quality/ brand whose capacity of oxidation filter is not less than 200 Ltr./ Hours] |
| 40 | PWD SOR (R & B) Page No.-270, Item No.-8.07/Providing & fixing Concrete Sign Board as per IRC specification of size 900 x 750 x 37 mm. thick made with RCC 1:1½:3 with pakur variety stone chips reinforced with double layer IRC febric (75 x 75 mm. mesh) and fixed with necessary nuts & bolts on two RC precast posts 100 mm. x 150 mm. of height 2.65 m. of which top 750 mm. is of section 100 x 13 mm. and 1.90 metre above GL & 0.75 metre below GL including digging hole, repacking the same with cement concrete 1:3:6 with jhama khoa or with local stone chips etc. complete including painting two coats on both faces lettering sign marks etc. as per direction of the Engineer-in-Charge. (The rate is inclusive of cost of reinforcement, concrete, shuttering, nuts & bolts, washer etc. complete.) |
AI Tender Summary
Tender Timeline
Jan 23, 2023
11:30 IST
Tender Published
Tender notice published.
CompletedJan 30, 2023