Tender For Special Repair / Relocation/ Shifting Of Water Pipe Lines And Electrical Poles From The Site Of Construction Of Perimeter Wall Under (Cce Nep) And Allied Works At Af Stn Kumbhirgram, kumbhirgram-Assam

Military Engineer Services-MES has published Tender For Special Repair / Relocation/ Shifting Of Water Pipe Lines And Electrical Poles From The Site Of Construction Of Perimeter Wall Under (Cce Nep) And Allied Works At Af Stn Kumbhirgram. Submission Date for this Tender is 02-03-2023. Electric Pole Tenders in kumbhirgram Assam. Bidders can get complete Tender details and download the document.




Tender Notice

35907000
Corrigendum : Tender For Special Repair / Relocation/ Shifting Of Water Pipe Lines And Electrical Poles From The Site Of Construction Of Perimeter Wall Under (Cce Nep) And Allied Works At Af Stn Kumbhirgram
Open Tender
Indian
Assam
kumbhirgram
02-03-2023

Tender Details

Tender For SPECIAL REPAIR / Relocation/ Shifting Of Water Pipe Lines And Electrical Poles From The Site Of Construction Of Perimeter Wall Under (Cce Nep) And Allied Works At Af Stn Kumbhirgram

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 06-Feb-2023 Revised BOQ BOQ 15-02-2023
2 15-Feb-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 22-02-2023
3 22-Feb-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 27-02-2023
4 27-Feb-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 02-03-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 87000.0 /-
Tender Value
Refer document

BOQ Items

NAME OF WORK : SR/ RELOCATION/ SHIFTING OF WATER PIPE LINES AND ELECTRICAL POLES FROM THE SITE OF CONSTRUCTION OF PERIMETER WALL UNDER (CCE NEP) AND ALLIED WORKS AT AF STN KUMBHIRGRAM
Sl. No. Item Description
1Excavation in trenches in soft/loosesoil etc n. exc 1.5 m wide and n.exc 1.5m in depth for foundation etc or for laying of pipe, cable etc and getting out complete all as specified and directed by Engineer-in-charge.
2Returning, filling in,trenches including spreading levelling watering and well rammming in layers not exceeding 25 cms in depth complete all as specified and as directed.
3Removal surplus to a distance not exceeding 50 mtr and depositing where directed at level not exceeding 1.5 mtr above the starting point all as specified and as directed.
4Taking up cast iron/DI water mains 150mm bore (including all fittings), with spigot and socket ends and lead joints including burning out joints and recovering lead complete as specified and directed
5All as per item No 04 above but 100mm dia complete all as specified and as directed.
6Supply and laying ductile Iron pipe, S/S including specials, Class “K-9”, 100 mm (4”) dia complete all as per specified
7Supply and laying ductile Iron pipe, S/S including specials, Class “K-9”, 150 mm (6”) dia complete all as per specified
8All as per item No 06 above but laying only (old pipe retrived from item No 5 above shall be reused)complete all as specified and as directed.
9All as per item No 07 above but laying only (old pipe retrived from item No 4 above shall be reused) complete all as specified and as directed.
10Supply and fix Sluice valve, flanged of class 1.6 PN, 100 mm (4”) dia.
11Supply and fix Sluice valve, flanged of class 1.6 PN, 150 mm (6”) dia.
12Supply and fix Cast Iron Air Valves with single air Outlets, conforming to IS 14845 of size 150 mm dia bore complete all as per specified
13M&L CI bend any type, radius and angles, tappers and type (straight, bend, increasing, decreasing, or double socket etc. Tee pipes single branch Y junction, double branch cross (all socket, socket and Spigot or flanged ends) collors, caps and plugs for the Pipes socket and Spigot.All socket and flanged upto bore of 150 mm complete all as specified and directed
14Taking up or down 20 mm bore steel tubing and connection including cleaning for relaying or credit from trenches/wall surfaces complete all as directed.
15All as per item No 14 above but 25mm dia complete all as specified and as directed.
16All as per item No 14 above but 50mm dia complete all as specified and as directed.
17All as per item No 14 above but 100mm dia complete all as specified and as directed.
18M&L for 20mm bore GI pipe medium grade with all fittings and fixedcomplete to walls and ceilings or laid in floor complete all as specified and as directed.
19All as per item No 18 above but 25mm dia complete all as specified and as directed.
20All as per item No 18 above but 50mm dia complete all as specified and as directed.
21All as per item No 18 above but 100mm dia complete all as specified and as directed.
22M&L for 50 mm bore gate valve cast copper alloy screwed down high pressure with clutch handle screwed both ends for Iron pipe including taking out of old unserviceable gate valve complete all as directed.
23All as per item No 22 above but 25mm dia complete all as specified and as directed.
24All as per item No 22 above but 20mm dia complete all as specified and as directed.
25M&L for construction ofbrick masonary valve pit with sub class "B" bricks built in cement mortar (1:6) of size 1.2 x 1.2 x 1.2 m (internal dimension) with one brick thick walling and 100mm thick mass concrete with PCC (1:4:8) type D2 with cement plastering 15mm thick with cement mortar (1:4) on internal & external surfaces, including MS Cover made out from 3mm thick MS Sheet including (50x50x6) mm angle iron framing on MS Cover embaded on concrete as well as on top wall of the valve pit & painting of MS cover with two coat of synthetic enamel paint over a coat of red oxide primer, including necessary earth work complete all as spcefied and as directed
26All as per item No 25 above butsize 0.9 x 0.9 x 1.05 m (internal dia) complete all as specified and as directed.
27S&F 1000 ltrs rotational moulded polyethelene water storage tank tripple layer (Cylinderical vertical with closed top) including connecting up pipes securing access coverscomplete all as specified and as directed.
28Excavation in trenches in soft/loosesoil etc n. exc 1.5 m wide and exc 1.5m but n.exc 3m in depth for foundation etc or for laying of pipe, cable etc and getting out complete all as specified and directed by Engineer-in-charge.
29Material and Labour for dry sand cushioning with coarse sand in trenches for protection of underground electric cable 8cm deep before laying the cable and 15cm thick after laying & stretching of cable complete all as specified and as directed.(Note:- Only punned thickness of 18cm shall be measured and paid)
30Supply and laying in trenches dry well burnt locally available sub class “B” bricks over sand cushioning for protection of cable complete all as per specified and directed.
31Taking out / down unserviceable HT/LT UG cable from existing trenches/duct/ poles of any cross sectional areaincluding disconnecting complete all as directed NOTE : (i) Earth work shall be measured and paid for separately under relevent items
32Supply, laying, jointing and testing of XLPE insulated, PVC bedded, Galvanized steel strip or wire armoured underground heavy duty electric power cable with aluminium conductor 1100 volts grade of cross sectional area 25 Sqmm 4 core, laid in trenches/ duct/ on pole including all necessary fixing arrangement such as lugs, glands end termination etc complete all as specified and as directed. (Note :- Excavation, earth work, bricks & sand cushioning shall be measured & paid separately)
33All as per item No 32 above but of size 16 sqmm 4 core complete all as specified and as directed.
34All as per item No 32 above but of size 10 sqmm 4 core complete all as specified and as directed.
35All as per item No 32 above but of size 10 sqmm 2 core complete all as specified and as directed.
36All as per item No 32 above but of size 70 sqmm 3.5 core complete all as specified and as directed.
37All as per item No 32 above but of size 50 sqmm 3.5 core complete all as specified and as directed.
38All as per item No 32 above but of size 120 sqmm 3.5 core complete all as specified and as directed.
39All as per item No 32 above but of size 95 sqmm 3.5 core complete all as specified and as directed.
40Supply, laying, jointing and testing of HT UG electric power cable, heavy duty 11KV (E) grade, XLPE insulated, screened, bedded, galvanised steel strip or wire armoured,aluminium conductor ofcross sectional area 95 sqmm, 3 core, laid in trenches/cable duct/under road crossing / on poles / panels complete all as specified and as directed.
41Taking down unserviceable/rusted LT/HT poles of any size/type complete all as specified and directed
42M&L for Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-55 (11 metres long) including painting with two coats of synthetic enamel paint of sky blue colour (upto 1.5 m above PCC copping) and aluminium paint for balance portion of the pole over a coat of red oxide primer complete all as specified and directed. (Note: Earth work and PCC foundation etc shall be measured and paid seperately under relevant item)
43All as per item No 42 above but erection only (old pole retrived vide item No 41 shall be re-used) complete all as specified and as directed.
44M&L for Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (09 metres long) including painting with two coats of synthetic enamel paint of sky blue colour (upto 1.5 m above PCC copping) and aluminium paint for balance portion of the pole over a coat of red oxide primer complete all as specified and directed. (Note: Earth work and PCC foundation etc shall be measured and paid seperately under relevant item)
45All as per item No 44 above but erection only (old pole retrived vide item No 41 shall be re-used) complete all as specified and as directed.
46Material and Labourfor PCC (1:2:4) type B1 (using 20 mm graded crushed stone aggregates) as in copping including necessary formwork complete all as specified and as directed.
47Material and Labourfor PCC (1:3:6) type C1 (using 20 mm graded crushed stone aggregates) as in foundation filling and mass concrete including necessary formwork complete all as specified and as directed.
48Material and Labour for PCC (1:4:8) type D2 (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed.
49S&F cross arms, bracing, support, clamps etc made out of mild steel channel or angle section of required size and shape including clamp, back plate with bolts, nuts & washers drilled for insulator bolts, welding bending cold or hot in any shape or size including all fixing arrangement on LT over head line and painted with two coats of synthetic enemel paint over a coat of red oxide primer complete all as directed.
50Supply and fixing in repair switches air break, gang operated, Triple pole, mechanically operated, mountedoninsulatorandsteel frame, with operating mechanism worked from ground level for current rating upto 400 amps, 11000 Volts grade complete all as specified and as directed.
51Supply, installing, testing and commissioning in repair HT lightening arrester expulsion type complete with all fittings discharging capacity 65 KA, 11000 volts grade complete all as specified and directed by Engr-in-Charge.
52Dismantling taking out carefully old/unserviceable existing LT panelboard of any type/ size including all accessories complete all as specified and directed
53Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6.3mm thick buried directly in ground earth pit not less than 2.25 mtr deep below normal ground level ) with top edge of plate not less than 1.5m below ground level, connecting to the Galvanisedearth lead wire 4.0mm , by means of nuts, bolts,check nuts and washer etc of galvanised iron and earth lead protected by provision of GI pipe light grade 32mm bore light grade from earthing test point or main controling switch as directed including providing funnel with 20mm bore GI pipe light grade, wire mesh,charcoal or coke and common salt in alternative layer of 15 Cm (compactedd thickness) all round the earth electrode,concrete earth pit in PCC (1:2:4) type B-1 using 20mm graded stone agagregates with 50mm thick cover of RCC (1:2:4) (re-inforced with 8mm dia TMT bar @15 cm C/C bothways and MS bar handle made of 10mm dia bar) including necessary earth work in excavation,returning in and removal of surplus soil to a distance not exceeding 50mtr, all as per electrical plate No 3 of MES Schedule Part-I including earthing pit cover etc. completeall as directed.
54M&L for shifting of existing HT feeder panel board with complete dismantling and dismounting from foundation, all cable connections, loop connections, busbars etc without breaking and damaging any parts from existing position and refixing the same in new location as directed including PCC foundation of required size and necessery connections and misc items complete. Note:(i) Errection of panel feeder pillar board shall be as directed and rate shall deemed to be included in the quoted rate (ii) Temporary arrangement for supply of electricity shall be made during repair/shifting period of the panel board and cost for the same shall deemed to be included in the quoted rate.
55M&L for shifting of existing LT feeder panel board with complete dismantling and dismounting from foundation, all cable connections, loop connections, busbars, MCCBs etc without breaking and damaging any parts of the panel from existing location and refixing the same in new location as directed including PCC foundation of required size and necessery connections and misc items complete. Note:(i) Errection of panel feeder pillar board shall be as directed and rate shall deemed to be included in the quoted rate (ii) Temporary arrangement for supply of electricity shall be made during repair/shifting period of the panel board and cost for the same shall deemed to be included in the quoted rate.
56M&L for shifting of existing Isolation Transformer upto 200 KVA including panel board with complete dismantling and dismounting from foundation, all cable connections, loop connections, busbars, MCCBs etc without breaking and damaging any parts of Isolation Transformer and LT panel and reinstalling the same in new location after constructing new foundation of required size and making all necessery connections of isolation transformer and LT panel to make functional complete all as specified and directed. Note:(i) Re-installation of panel board and transformer shall be as directed and rate shall deemed to be included in the quoted rate (ii) Temporary arrangement for supply of electricity shall be made during repair/shifting period of the panel board and cost for the same shall deemed to be included in the quoted rate.
57Dismantling/Taking down of unserviceable over head ACSR conductor of any size complete all as directed.
Disclaimer :