Shifting Of Substation Building Including Electrical Equipments And Certain Allied Works At Cfees Under Ge I Rnd Delhi - Schedule `A Section- I Building Work As Underis Prepriced By Mes Based On Ssr ( Pt-Ii ) -2020 2 Lump Sum Price Workout Of Sch A Sec-I ( Building Work ) 3 Schedule A Section Ii To Section X Are Under Ser No. 2.01 To 2. 10 Are Prepriced By Mes On Ssr ( Pt-Ii ) -2020 4 Lump Sum Price Worked Out By The Contractor For“Excavation And Earth Work” As Listed In Schedule ‘A’Section- Ii 5 Lump Sum Price Worked Out By The Contractor For“Sewage Disposal” As Listed In Schedule ‘A’Section- Iii 6 Lump Sum Price Worked Out By The Contractor For“Road / Path / Hardstanding” As Listed In Schedule ‘A’Section- Iv 7 Lump Sum Price Worked Out By The Contractor For“Area Drainage” As Listed In Schedule ‘A’Section- V 8 Lump Sum Price Worked Out By The Contractor For“Internal Electrification” As Listed In Schedule ‘A’Section- Vi 9 Lump Sum Price Worked Out By The Contractor For“Internal Water Supply” As Listed In Schedule ‘A’Section- Vii 10 Lump Sum Price Worked Out By The Contractor ForExternal Electrification” As Listed In Schedule ‘A’Section- Viii 11 Lump Sum Price Worked Out By The Contractor ForExternal Water Supply” As Listed In Schedule ‘A’Section- Ix 12 Lump Sum Price Worked Out By The Contractor ForLightening Protection” As Listed In Schedule ‘A’Section- X 13 Schedule `A Section - Xi Misc Items ( To Be Quoted By The Tenderer ) 14 External Electric Supply 15 Disconnecting Electric Connection And Earthing Of Transformer Floor Mounting Indoor Type, Taking Out From Sub Station Of Capacity 400 Kva, 11 / 433 Kv Loading / Unloading For Shifting To Newly Construcred Sub Station And Installation, Commissioning And Testing In Side Sub Station On Floor Including Replacement Of Silica Gel, Centrifuging / Dehydration Of Transformer Oil And Topping Up Of Transformer Oil 40 Kv ( Appx 20 Ltrs ) , Lt Bushing With Studes Of Copper, Etc All As Specified And Directed By Engr-In-Charge. 16 Disconnecting Electric Connection, And Earthing Of Ht Vcb Panel Consisting Of 5 Nos Vcb Of 400 Amps 11 Ka Totally Enclosed, Dismantling, Takingout, Loading / Unloadingsafely Shifting Inside Newly Constructed Sub Station And Re-Installation, Commissioning And Testing Ht Panel Rated Voltage 11 Kv System Voltage 12 Kv, 21 Kv For 3 Sec Raputating Capacity, 3 Phase, 50 Hz, Totally Enclosed Floor Mounted With Common Tinned Busbar Indoor Type Triple Pole Ht Control Panel Confirming To Is-3427, Extandable Porton Horizontally / Vertically Isolated Dust And Vermin Proof, Horizontal Draw Out Type With Grounded Neutral System Including Internal Connection Contral Fuses / Mcb For 1 Nos Incoming And 4 Nos Out Going 400 Amps, 3 Phase 250 Mva Raputaring Capacity Vcb With And Including:- ( A ) One Set Of 3 Phase Copper Bus Bar Air Insulated ( B ) Two Set Of 3 Nos Resin Cast In Capsulatedtwin Secondary Current Transformer Of Dual Ratio 100-50 / 5 Amps Andacuracy Class 0.5 For Metering And 5P10 For Protection Of Suitable Burden For Protection As Well As Metering. ( C ) Electronic Numirical Self Powered Programeable Type Idmt Non Directional Shunt Trip Relay 3 For Over Current Protection With Setting 50-200% And One For Earth Fault Protection With Setting 20% To 80%.- 2 Set. ( D ) Led Indicating Lamps In Specified Colours For On / Off Condition Of Vcb, Vcb Triping On Fault, Trip Circuit Healty With Push Button, Spring Charging Condition, Breaker Isolation Position, Breaker In Service Position. ( E ) Internal Wiring Of The Switch Gear With Control Fls Pvc Insulated Multi Stranded Flxible Copper Conductor Cable Not Less Than 2.5 Sq Mm Including Control Breakers / Fuses, Dc / Ac On / Off Switch Thermostate And Space Heater Illumination Lamp. 17 ( F ) Any Civil Work Required For The Installation Of The System. ( G ) 96 Mm Square Dia Digital Volt Meter With Three Way On / Off In Built Selector Switch Aux Supply 110 Volts. ( H ) 96 Mm Square Ct Operated Digital Amps Meter With Three Way On / Off In Built Selector Switch Aux Supply 110 Volts. ( J ) Installation / Fixing To Panel Obtained From Existing Panel As Under Including Testing, Connecting ( I ) One Set Of 3 Phase 400 Amps Air Insulated Tinned Copper Bus Bar With Insulated Colour Coding. ( Ii ) One Set Of Side Frame For Housing For Circiut Breaker Carriage. ( Iii ) One Set Of Mechanical Interlock And Automatic Shutter Gear. ( Iv ) Five Nos400 Amps Triple Pole 250 Mva Rupturing Capacity Vacuun Circuit Breaker With Automatic Drop Out And Manually Operated Spring Closed Mechanism Operating By 230 Volt 50 Hz Single Phase Electric Motor Of Suitable Rating Complete With Contacts, Close / Neutral / Trip Switches, Closing Coil, Test / Isolation Switches With Internal Connections And Fully Confirmed To Is-13118, Trunk Type Mechanically On / Off Indicator, And Degree Of Protection -Ip-4X. ( V ) One Circuit Breaker Carriage Complete With Self Contained Raising & Lowering Mechanism For Isolation Purpose ( Vi ) Potential Transformer 11 / 110 Volts, 3 Phase Including Connection Etc. ( Vii ) Cable Boxes Suitable For Ht 11 Kv Xlpe 3 Core Cable Upto 120 Sq Mm Either Side. ( Viii ) Data Logger And Associated Mf Digital Meters For Real Time Data Monitoring Including Refixing The Same With Previous Configuration In Consultation With Oem. 18 Disconnecting Lt Panel And Earthing Indoor Type Floor Mounted For Shifting / Replacement And Supply And Fixing / Installation In New Sub Station Bldg, Fabricated With 2 Mm Thick Crca Sheet Duly Cpri Approved, Both Side Openable And Size ( 3.5X2x1 ) Meters, Indoor Type 3 Phase And Neutral 4 Wire 440 Volts Cubical Type Duly Powder Coating Painted Having Busbar Chamber And Separate Compartment For Out Going / Incoming With And Including Copper Bus Bar Of Cap 1500 Amps-4 Nos On Apoxy Insulator 1100 Volt Grade, Panel Shall Be Mounted Minimum Frame 300 Mm Height From Gl, Copper Internal Wiring / Connection With And Including For Following Accessories Incomming ( A ) 4-Pole, 800A, Electrically Operated, Drawout Type 433V, 800A, Air-Circuit Breaker, Microprocessor Based Released For Over Load, Short Circuit And Earth Fault Protection, Adjustab;Le Type With Icu = 100% Of Ics Of 50Ka Breaking Capacity. ( B ) Copper Busbar 1500A Tpn Duly Screwed. ( C ) Multification Meter Varf Type I.E. Volts, Current, Power Factor, Power, Minimum 3 Line Display And Rs-485 Port Of Communication, And Having Featureof Storage Of Data Of Last Minmum Three Months. 02 Nos ( D ) Led Indications For R-Y-B-On-Off-Trip ( E ) Suitable Provision To Receive Incoming From Transformer. 19 Outgoing ( A ) Mccb 415V, 400 A, 4 Pole, 35Ka, 50Hzwith Complete Accessories - 03 Nos ( B ) Mccb 415V, 250 A, 4 Pole, 35Ka, 50Hz With Complete Accessories - 01 No ( C ) Mccb 415V, 200 A, 4 Pole, 25Ka, 50Hz With Complete Accessories - 11 Nos ( 02 Spare ) ( D ) Mccb 415V, 160 A, 4 Pole, 25Ka, 50Hz With Complete Accessories - 02 Nos ( E ) Mccb 415V, 125 A, 4 Pole, 25Ka, 50Hz With Complete Accessories - 02 Nos ( F ) Mccb 415V, 100 A, 4 Pole, 25Ka, 50Hz With Complete Accessories - 03 Nosnote:- The Lt Panel Drawing Shall Be Approved By The Accepting Authority Before Placing Order Of Lt Panel Board. 20 S&F Shock Treatment Chart ( Prescribed Under I.E. Rules ) Dully Aluminium Framed With Glass And Supported From Back With Hard Board With Supply Of All Material, Labour And T&P Etc For Proper Completion Of Work. ( Front Size 900 Mm X 600 Mm ) 21 Supply & Fixing First Aid Box As Approved By Indian Red Cross Conforming To Is 2217 22 Supply And Fixing Of Co2 Fire Extinguishers 4.5 Kg Cap Complete In All Respect Isi : 15683 Marked 23 Supply And Fixing Of Abc Fire Extinguishers 4 Kg Cap Complete In All Respect Isi : 15683 Marked 24 Supply And Fire Point With Shade And Accessories Like As Bucket, Fire Bitter, Fire Hook, Digging Tool, Bucket Stand Made Of Ms Angle Suitable For With Four Nos Fire Buckets Of 9.5 Ltrs Capacity Etc Complete All As Specified And Directed. 25 S&F Fabricated Cubical Type Sign Board With Including Ms Channel With Transperant Acrylic Sheet With Letters Enbosed Like Mes Sub Station Cfees Including Grouting Fixing On Ground With The Help Of Angle Iron Of Size 2 Mtr X 1.5 Mtrs X 20 Cm And 02 Nos Led Tube Light 20 Watts With Lamps Connection And Flexible Wire Of Required Length Complete All As Directed. 26 M&L For Boring Of Holes Under Road, Pavement Hard Standing By Trenchess Techonology Using Ultra Sound Technique / Manually / Mechanically And Necessary Machine Including Supply And Laying Of 150 Mm Dia Hdpe / Gi Pipe Complete All As Specified And Directed By Engineer-In-Charge. 27 Taking Down Of Old Unservisible Cable Of Size 400 / 300 Sqmmcable From Soft / Hard Soil In Trenches / Under Hard Stand Including Excavation / Labour / Necessary T&P And Refilling The Same With Pcc Morter ( 1:4:8 ) Complete All As Specified And Directed. 28 Taking Down Of Old Unservisible Cable Of Size 240 / 185 / 120 Sqmm Cable From Soft / Hard Soil In Trenches / Under Hard Stand Including Excavation / Labour / Necessary T&P And Refilling The Same With Pcc Morter ( 1:4:8 ) Complete All As Specified And Directed. 29 Supply And Fixing Of Ht / Lt Route Indicator Made Of Cast Iron And Length Not Less Than 600 Mm Long Including Pcc Foundation And All Connected Items Complete All As Specified And Directed. 30 Taking Down Of Old Unservisible Cable Of Size 95 / 70 / 50 Sqmm Cable From Soft / Hard Soil In Trenches / Under Hard Stand Including Excavation / Labour / Necessary T&P And Refilling The Same With Pcc Morter ( 1:4:8 ) Complete All As Specified And Directed. 31 External Water Supplym&L For Cutting The Existing 50 Mm Dia Gi Pipe And Inserting T Reducer Of Size 50 / 25 Mm Including All Necessary Fittings And Fixtures All As Specified And As Directed. 32 Material And Labour For Construction Of Valve Pit Of Brick Masonry Of Size ( 750X750x750 Mm ) Internal Dimension Complete With Internal Plaster In Cement Mortar 1:4, Angle Iron, 3.15Mm Thick Ms Sheet Cover And Locking Arrangementincluding Excavation And Earth Work And Pcc1:3:6 Type With Provision Of Two Coat Of Synthetic Enamal Paint Over One Coat Of Red Oxide Primer Complete All As Specified And As Directed. 33 Internal Electrificationm&L For Point Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq Mm Frls Pvc Insulated Copper Conductor Single Core Cablein Surface / Recessed Steel Conduit, With Modular Switch, Modular Plate Suitable Gi Box And Earthing The Point With 1.5 Sq Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required And Including Taking Down Point Wiring 34 M&L For Wiring For Power Point With 4 Sq Mm Frls Pvc Insulated Copper Conductor Single Core Cablein Surface / Recessed Steel Conduit, With Modular Switch, Modular Plate Suitable Gi Box And Earthing The Point With 4 Sq Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required And Including Taking Down Point Wiring 35 Supply And Fixing In Two Module Stepped Type Electronic Fan Regulator, Step Type, Two Module 120 Watt 230 Volt And Making All Necessary Connections Complete All As Specified And Directed. 36 Supply And Fixing Of Led Tube Light Along With Fixture 4 Feet, 20 Watt Led Indoor Industrial Crca Ms Box Type Luminaire Complete With Led Retrofit T8 Polycarbonate Tube And Making All Electric Connections With Twin Core Pvc Insulated, Multistranded Copper Conductor Flexible Cable 1.5 Sqmm Including Taking Down Old Unserviceable Light Fitting Etc Complete All As Specified And Directed Complete All As Specified And Directed. 37 Supply And Fixing Of Led Tube Light Along With Fixture 2 Feet, 10 Watt Led Indoor Industrial Crca Ms Box Type Luminaire Complete With Led Retrofit T8 Polycarbonate Tube And Making All Electric Connections With Twin Core Pvc Insulated, Multistranded Copper Conductor Flexible Cable 1.5 Sqmm Including Taking Down Old Unserviceable Light Fitting Etc Complete All As Specified And Directed Complete All As Specified And Directed. 38 M&L For Earthing With Galvanised Iron Earth Plate Electrode 600 X 600& 6 Mm Thick Buried Directly In Ground ( Earth Pit Not Less Than 2.25 Metre Deep Below Normal Gl ) With Top Of Earth Plate Not Less Than 1.5 Metre Below Gl Connected To Gi Earth Strip 25 X 4 Mm Connected To Earth Plate Electrode By Means Of Gi Nuts, Bolts & Washers Earth Wire Protected With & Including 40 Mm Dia Light Grade Isi Marked Gi Pipenot Less Than 7.5 Metre Long All As Shown In Electrical Plate No 3 Of Mes Schedule Part I, With & Including; Pcc 1:3:6 Type C1 Pit With Cover Of Rcc 1:2:4 B1 Reinforced With Welded Steel Wire Fabric Not Less Than 4 Kg Per Sqm Watering Arrangements With 20 Mm Gi Medium Grade Pipe Isi Marked , Gi Funnel With Gi Mesh, Filling With Mixture Of Common Salt & Charcoal, Necessary Excavation And Earth Works In Any Type Of Soil, Including Test Point, Testing & Commissioning, Complete. 39 Supply And Fixing 1400 Mm Sweep Ceiling Fan Metal Body 300 Rpm With Down Rod And All Connected Acseeories Complete All As Specified And Directed. 40 Supply And Fixing Of Surface / Recess Mounting Vertical Type12 Way 240 V, Spndistribution Board Of Sheet Steel Dust Protected Duly Powder Painted Inclusive Of 200 A Tinned Copper Bus Bar Common Neutral Link Earth Bar Din Bar For Mounting Mcbs ( But Without Mcbs And Incomer ) As Required. 41 Supply And Fixing Ofmcb 6 Amps To 32 Amps Sp 10 Ka C Series Complete All As Specified And Directed 42 Supply And Fixing Ofmcb 63 Amps Spn, Complete All As Specified And Directed 43 Supply And Fixing Led Security Light Fitting Of 45 Watts With 32 Mm Bore Gi Pipe Bend Shape Not Less Than 1.2 Mtrs 2 Nos Claimp With Nut, Bolt Washer Etc And Fixed On Wall Upto 2 Floor Building Complete All As Specified And Directed. 44 Supplying And Fixing 2 Module Socket, 3 Pin 5 / 6 Amps Gi Box Alongwith Modular Base & Cover Plate For Modular Socket In Recess Etc Complete. 45 Supplying And Fixing 2 Module Socket , 3 Pin 15 / 16 Amps Gi Box Alongwith Modular Base & Cover Plate For Modular Socket In Recess Etc Complete. 46 Internal Water Supplys&Fcp Jet Spray With Tube 1.20 Metre Long Single Symphonic Ewc Complete All As Specified And Directed.