Tender For Providing Hvac Services With 67 Tr Ductable Unit And Electric Work Of Medicine Iccu, faridkot-Punjab

Baba Farid University Of Helath Sciences has published Tender For Providing Hvac Services With 67 Tr Ductable Unit And Electric Work Of Medicine Iccu. Submission Date for this Tender is 13-02-2023. Electrification Work Tenders in faridkot Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

35898465
Tender For Providing Hvac Services With 67 Tr Ductable Unit And Electric Work Of Medicine Iccu
Open Tender
Indian
Punjab
faridkot
13-02-2023

Tender Details

Providing Hvac Services With 67 Tr Ductable Unit And Electric Work Of Medicine Iccu

Key Value

Document Fees
INR 1180 /-
EMD
INR 87000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work:Providing HVAC services with 67 Tr. (Ductable Unit) including false ceiling, repair of toilet, wall tiles and electrical work of Medicine ICCU in GGS Medical College & Hospital, Faidkot.
Sl. No. Item Description
1Supplying & Installation,Testingand commissioning of17 TR R-410with twin scroll compressor capacity outdoor unit with matching capacity indoor unit suitable for atleast 6700 cfm air capacity ductable split air conditioners fittingcomplete withincluding MS painted stand for outdoor units suitable size foundation and allied minor civil works as per drawings, spicifacations and instructions of engineer in charge offollowing rating including electric control panel & fitting as per specifications (Make Carrier / Hitachi / Daikin/ Blue Star) (Make as per DNIT on page No. 57)
2Supplying & Installation,Testingand commissioning of11 TR R-410 with Single / twin scroll compressor capacity outdoor unit with matching capacity indoor unit suitable for atleast 4400 cfm air capacity ductable split air conditioners fittingcomplete withincluding MS painted stand for outdoor units & refrigerant, suitable size foundation and allied minor civil works as per drawings, spicifacations and instructions of engineer in charge offollowing rating including electric control panel & fitting as per specifications (Make Carrier / Hitachi / Daikin/ Blue Star)
3Supplying & Installation, Testingand commissioning of5.5 TR R-410 with scroll compressor capacity outdoor unit with matching capacity indoor unit suitable for atleast 2200 cfm air capacity ductable split air conditioners fittingcomplete withincluding MS painted stand for outdoor units & refrigerant, suitable size foundation and allied minor civil works as per drawings, spicifacations and instructions of engineer in charge offollowing rating including electric control panel & fitting as per specifications (Make Carrier / Hitachi / Daikin/ Blue Star)
4Supplying & Installation, Testingand commissioning of refrigerant copper piping 17 TR units size as per OEM design manual (per circuit) complete with all fitting such as bends, tees, elbow ets. Including insulation as per sepecifications between indoor and outdoor units. the quoted rates shall include rates for chiseling, making good of wall and clamps etc.
5Supplying & Installation, Testingand commissioning of refrigerant copper piping 11 TR units size as per OEM design manual (per circuit) complete with all fitting such as bends, tees, elbow ets. Including insulation as per sepecifications between indoor and outdoor units. the quoted rates shall include rates for chiseling, making good of wall and clamps etc.
6Supplying & Installation, Testingand commissioning of refrigerant copper piping 5.5 TR units size as per OEM design manual (per circuit) complete with all fitting such as bends, tees, elbow ets. Including insulation as per sepecifications between indoor and outdoor units. the quoted rates shall include rates for chiseling, making good of wall and clamps etc.
7Providing and fixing in position the following 25 mm dia pipes PVC ( Min 3 mm thick) Heavy duty pipes cut to required lengths and installed with all screwed joints with the necessary elbows, tees and reducers etc duly insulatedwith 6 mm thick insulationas per specifications.
8Supply ,fabrication & installation of GS sheetmetal ducting complete with supports ets. As per is 655 and approved drawingand as per specification of 24 gauge.
9Supply ,fabrication & installation of GS sheetmetal ducting complete with supports ets. As per is 655 and approved drawingand as per specification of 22 gauge.
10Supply and fixing of UL approved thermal insulation on AC ducts with 13 mm thick closed cell Nitrile rubber Class O insulationincluding providing adhesive, adhesive tapes etc. as per specifications.
11Supply ,installation, testing and commissioning of open cell nitril rubber of 10 mm thickness with anti- microbial properties with adhesive complete as per specifications.
12Supply, fabrication, installation and testing the flexible connections constructed of fire resistance flexible double canvas sleeve connection between each inder unitand duct as per approved drawings and sepecifications .
13Supplying, fixing, testing and commissioning of motor actuated Dampers supply air duct at mouth of m/c, of requires sizes including control wiring. The damper shall be motorized and spring return so as to close the damper as per specifications and as required. The spring return action shall be in-built mechanism and not externally mounted. The control wiring shall be interlocked ion such a way that along with actuation of damper-closing mechanism, the AHU fan motor gets automatically switched off.Damper as described above, as per specifications and complete in all respects.
14Electric actuator with necessary linkage to actuatedampers complete with required wiring and associated accessories.
15Supply, installation, testing and balancing of powder coated extruded aluminum construction Air Grilles without volume control dampers.
16Supply, installation, testing and balancing of powder coated extruded aluminum construction Linear Air Grilles without volume control dampers.
17Supply, installation, testing and balancing of powder coated extruded aluminum square shape ceiling diffusers with removable core and anti smudge ring & aluminum volume control dampers as per specifications
18Supply, installation, testing and balancing ofPowder coated extruded aluminium construction square shape return air diffusers with removable core,anti smudge ring & without volume control damper as per specifications.
19Supplying & fixing of opposed blade aluminium construction volume control dampers in supply air duct collars as per approved drawings and specifications.
20Supply, installation, testing and balancing of inlet air louvers with bird screen and volume damper for fresh air in powder coated extruded aluminium construction as per specifications and approved shop drawings.
21Supply, intallation and testing and commissioning of refrigeration control cable with all fitting and including insulation as per specifacation between indoor and outdoor unti 1.5 X 8 Core copper wire including PVC pipe & clamping proper on wall complete in all respect. .
22Supplying and laying of following 1100 volt grade PVC insulated sheathed conductor unarmoured cables / copper cables on tays, in trenches on walls clamped to wall with suitable clamps , saddles ,and fixing bolts , or laying in ground including cost of digging brick and sand protection and including commissioning of 4 corex 10 sqmm wire including PVC pipecomplete in all respect.
23Supplying and laying of following 1100 volt grade PVC insulated sheathed conductor unarmoured cables / copper cables on tays, in trenches on walls clamped to wall with suitable clamps , saddles ,and fixing bolts , or laying in ground including cost of digging brick and sand protection and including commissioning of 4 Sqmmx 4 Core.
24Supply &Erection of Step type Heater 3 KW X 6 No. in ducting including MCB TPN , SCR fuse ,Thermostat for high temp, Airflow suitch complete in all respect asanddesired by the Engineer in charge at site for 17 TR.
25Supply &Erection of Step type Heater 3 KW X 3 No. in ducting including MCB TPN , SCR fuse ,Thermostat for high temp, Airflow suitch complete in all respect asanddesired by the Engineer in charge at site for 11 TR.
26Supply &Erection of Step type Heater 3 KW X 2 No. in ducting including MCB TPN , SCR fuse ,Thermostat for high temp, Airflow suitch complete in all respect asanddesired by the Engineer in charge at site for 5.5 TR
27Civil Work (Renovation of Medicine ICU) Scraping of cement plaster from walls
2812.5 mm thick cement plaster 1:5
29115 mm thick brick wall in cement sand motor 1:4 without reinforcment in superstructure.
30Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 600 x600 mm as approved by Engineer-in- Charge
31Renewing glass panes with putty and nails wherever necessary. Glass panes weighing 10.75 Kg/sqm
32Repair of existing aluminium doors/partitions at site and making good the same upto required.
33Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , Fixed partition
34Moveable partition
35Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in paneling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer-In-Charge. Prelaminated particle board with decorative lamination on Both side.
36Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminum snap beading shall be paid in basic item)Float glass panes of 5 mm thickness
37Cost of aluminum fittings complete for doors, windows such as tower bolts, handles,Stoppers and screw etc. for these fittings (Excluding sliding bolt) For shutter area up to 0.50 sqm
38Providing and fixing door lock for aluminium doors complete.
39Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish
40Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade
41Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.
42Regrading terracing of mud plaster covered with tiles or bricks in cement by dismantling tiles or bricks, removing mud plaster, preparing the surface of mud plaster to proper, slope, relaying mud plaster Gobri leaping and tiles or bricks grouted in cement mortar 1:3 (1 cement and 3 fine sand) including replacing unserviceable tiles, or bricks with new over and disposal of unserviceable material to the dumping ground within 50 m lead (The cost of new tiles or bricks excluded).
43Floating coat of 1:5mm thick neat cement laid in one operation to the topping
44Public Health Items Dismantling brick or flagged stone flooring without concrete base.
45Dismantling Cement concrete plain 1:4:8 or 1:5:10
46Dismantling glazed tiles (to be carefully removed).
47Removing cinder from sunken ara.
48Washing concrete surface scrubbing with brushes including preparing and laying slurry
49Cement concrete 1:2:4 with stone ballast or shingle mixing by manual means
50Providing & laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry cost of neat cement using 2.75 kg/sqm. of cement admixed with water proofingcompound conforming to IS. 2645 and approved by Engineer- in- charge over the RCC slab including adjoining walls upto 300mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/ brick bats 25mm to 115mm size with 50% of cement mortar 1:5 (1 cement :5 coarse sand) admixed with water proofing ompound conforming to IS: 2645 and approved by Engineer-in-charge over 20mm thick layer of cement mortar of mix 1:5 ( 1 cement L5 coarse sand) admixed with water proofing compound conforming to IS :2645 and approved by Engineer.
51Supplying and filling cinder on roof (Ist story) including light ramming
52Screed of 50mm thick cement concrete 1:8:16 to be laid below the topping using mechanical mixer for mixing of material
53Providing ,laying, jointing, fixing and testing ISI Marked G.I. Pipe (as per IS 1239) BClass including cost of specials (such as tees, bends, sockets, elbows etc.) ,painting with anti corrosive bitumastic paint, testing, cutting, threading Inside building complete 15mm i/d
5420 mm i/d
5525mm i/d
56Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications. 90mm o/d pipe of 6 Kgf. / sqcm
57110mm o/d pipe of 6 Kgf. / sqcm
58Providing and fixing in position SWR UPVC special for soil waste vent or anti syphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining. B) For 110 mm O/d pipes Bend with door
59Single tee with door
60Cowl
61P Trap/floor trap 110 mmX110mm
62P Trap/floor trap 110 mmX75mm
63C) For 90mm o/d pipes Bend with door
64Single tee with door
65Cowl
66coupler
67Providing, fixing and jointing G.I Union Couplings(of approved make with the approval EIC) as per IS 1879 in G.I. Pipe lines complete in all respect. 25mm i/d G.I. Union
68Providing, fixing and jointing ISI Marked Gun- Metal peet valves (Heavy Pattern) as per IS 778 with hand wheels, on G.I. Pipe lines laid in the ground or inside buildings including all carriages complete.25mm i/d Gun Metal peet valve heavy pattern
69Providing and fixing in position Chinaware Indian Orisa water closet size 580x440 mm of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern ISI makred including cost of PVC long bend 32 mm dia complete in all respect and to the entire satisfaction of Engineer-in-charge.
70Providing and fixing in position Chinaware European type water closet P trap or S trap of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern ISI marked, PVC short bend 32 mm dia including cost of seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge.
71Providing and fixing jet spray with 2"-6" long PVC pipe. With C.P. Brass nut
72Providing and fixing in position vitreous Chinaware white lIndian make large flat back or angular lipped front urinal 375 x 390 x 590 mm of approved make (to the approval of the Engineer-in-charge) consisting of C.P. brass Urinal waste Coupling dome type 32mm outer length 75 mm , C.P. brass Urinal Spreader Ocular-Regular and C.P. brass tube connection 300 mm long complete
73Providing and fixing partition for different type of urinals 19 to 20 mm thick Granite stone partition size 375mm x 750mm
74Providing & Fixing in postion stop cock / Angle valve of approved make (to the approval of Engineer-in-charge ) complete in all respect. C.P.brass 15mm Angle valve without flange
75C.P.brass 20mm concealed stop cock with flange
76Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) including Rack Bolt Screw Pair 115mm long without CP fittings complete in all respect.Size 49 cm dia (above counter round)
77Providing & fixing in position PVC flexible tube connection of approved make (to the approval of Engineer-in-charge ) complete in all respect.PVC tube connection of size 15 mm x 450 mm with C.P. Brass nut
78Providing & Fixing in position C.P. Brass extension piece 25mm long to 100mm long of approved make (to the approval of Engineer-in-charge )with various fixtures complete in all respect.C.P. Brass extension piece, 25mm long to 50mm long
79Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge )complete in all respect.Brass Bib cock/Stop cock 15mm x 400gm
80Providing and fixing P.V.C Waste Pipe Collapsiable 32mm complete in all respect
81Providing & Fixing in position C.P. Brass flange Dome of approved make (to the approval of Engineer-in-charge ) under various fixtures complete in all respect.
82Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 200 x 300 mm, 100x200mm, 200x200mm as approved by Engineer-in-Charge
83Providing and laying Anti skid Ceramic floor tiles of size 300x300 mm x 10 mm thick of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on flooring skirting and dado in 12.5mm thick cement plaster 1:3 in base and jointed with @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., completewhite cement slurry in joints including corners angles and beading
84Black Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps.
85False Ceiling Work Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material within 50 meters lead as directed by Engineer-in-charge
86Providing and Fixing ceiling consisting of 12.5mm thick Gypsum Board of any size G.I. Cradling hanged from the ceiling by means of G.I. hanger complete as per drawings,specifications and tothe entire satisfaction of engineer-in- charge.
87Electricl work RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Supply & erection of wiring fan point (Without fan box) (Make as per DNIT on page No. 27-28)
88Supply & erection of wiring light point
89Wiring 6Amp. Plug control comprising wall socket point RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES
90Supply & erection of wiring 16Amp. Plug control comprising wall socket point RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES
91Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge overall size 1.5 sq.mm (Un-sheathed)
92Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge overall size 2.5 sq.mm (Un-sheathed)
93Supply & erection of PVC Conduit Pipes (ISImarked)asperIS9537:Part-III& HDPEpipes(ISImarked)asper IS:4984:1995 for wiring purposes includingbends,junctionboxes,Steel hooks,M.S.saddleclampsandother petty materials etc., as per PWD General Specifications Heavy Gauge PVC Conduit Pipe 25mm dia. (On Surface)
94Supply and erection of Miniature Circuit Breaker MCB"s for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energylimitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs MCB Single Pole 6-32amp. (10kA, Curve-C)
95MCB Four Pole 50, 63amp. (10kA, Curve-C)
96Supply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dustprotected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, colorcoded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO"s/ RCCB"s in the distribution board (For SP&N distribution board with provision DP MCB"s/ RCCB"s/ RCBO"s as incomer and SP MCB"s as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB"s/ RCCB"s/ RCBO"s as incomer and SP MCB"s as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:-TP&N Horizontal Double Door Distribution Board 6 way each
97Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader links and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:- MCCB Four Pole 200amp., 415volts, =25kA Fixed Magnetic and Adjustable Thermal Setting
98Supply and erection of sheet metal busbar chamber (factory fabricated) duly powder coated on existing surface with required 4Nos. of tin plated copper busbar strips of suitable length and crosssectional area mounted on DMC/ SMC moulds at sufficient distance, enclosure made of M.S. sheet 1.6mm thick with hinged cover and lock, fitted with dust excluding gaskets and secured with sufficient no. of cadmium plated iron screws and of given overall dimensions and to be fixed with G.I. bolts and nuts/ rag bolts and nuts etc. complete with all accessories including connections with suitable size of thimbles, bonding to the existing earth and painting etc. as desired by the Engineer-in-charge at site Bus Bar Chamber 200amp., 415volts Overall Dimensions (350mm x 450mm x 150mm) nominal
99Supply and Erection of Recess mounted white powder coated CRCA housing wth full window acrylic diffuser LED Panel 2"x2" 36w of Make Jaquar Item Code LULTO IS 036XC or its equilant make Phillips / Crompton including cutting of ceiling , erection, connections and testing etc. of the same with petty material as required at site complete in all respects as approved and desired by the Engineer in charge at site.
100Supply and erection of High quality aluminium extruded with decorative end caps glazed LED batten of Make Jaquar Item Code LGLZ01x020XC or Its equilant Make and Cat. of Philips / Crompton including erection of the same with connections, testing etc.complete in all respects as approved and desired by the Engineer in-charge at site. (BFUHS/UWD/2019/10622 Dt 27/5/2019)
101Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:- Make- Polycab, Havells, RR Kabel, Gemscab, KEI, Grandly, Ultracab, universal"s unistar, Rallison, SCI Overall size 300sq.mm (3½ Core) Armoured (Loose)
102Supply &Erection of MCB Four Pole 50, 63amp. (10kA, Curve-C)
103Supply &Erection of SP&N Double Door Distribution Board 4 way each
104Supply and erection of sheet metal double door vertical distribution boards IP 43-IK09 metal door (dust protected) as per IS:8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars for each phase, 2 Nos. shrouded neutral bars, 2Nos. earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting MCCB"s as incomer and outgoings SP/TP miniature circuit breakers in the distribution board as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc.:-TP&N Double Door Vertical DB"s 8 way each (With provision of FP MCCB 125 amp.)
105Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader terminal links, Extended rotary handle and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etcMCCB Four Pole 250 amp., 415volts, =25kA Fixed Magnetic and Adjustable Thermal Setting
106Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid (On Surface) as per PWD General Specifications Overall size 185 sq.mm 3.5 Core Un-armoured (On-Surface)