Law and Justice Local Bodies Closing in 0 days TDR #35888957

Tender For Construction And Installation Of 2 Nos. Drinking Water Solar Plant With Ir Purifilter And Submersible Pump Within Balabhut G.P Under Tufanganj-I Block. Activity Code-66536968

Issued by Local Bodies · balabhut, West Bengal
Tender Value
8.81 Lakhs
Estimated cost
Bid Submission
28 Jan 2023
0 days left
EMD
17623
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
balabhut → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Construction And Installation Of 2 Nos. Drinking Water Solar Plant With Ir Purifilter And Submersible Pump Within Balabhut G.P Under Tufanganj-I Block. Activity Code-66536968

BOQ

Name of Work: Construction and Installation of Drinking Water Solar Plant with IR Purifilter and Submersible Pump in different places within Tufanganj-I Block.
Sl. No. Item Description
1Earth work in excavation for foundation trenches in all sorts of soil including removing spreading of staking the spoils within a lead of 75m as directed including trimming the side of trenches leveling, dressingand ramming the button, bailingDepth of excavation not exceeding 1.5m
2Earth work in filling in foundation trenches or plinth with good earth in layers not exceeding 15cm including watering, ramming etc. layer by layer complete(a) With earth obtained from excavation of foundation.
3Single brick flat soling of picked jhama bricks including ramming and dressing bed to proper level and fitting joints with powdered earth or local sand.
4Cement concrete with 30 mm down graded shingles excluding shuttering. N.B. Variety(a) 1:3:6 proportion. In ground floor
5Cement concrete of Mix (1:1.5:3) M-20 with 20m m. down well-graded stone chips excluding shuttering and reinforcement.River Bazree
6Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor)(a)25 mm.to 30mm thick wooden shuttering as per.
7Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction..(a) For works in foundation and upto roof of ground floor / upto 4 mII. JSW / JSPL / SHYAM / SRMB / BMASL / ELECROSTEEL / SSL In Ground Floor :-
8Neat cement punning about 1.5mm thick in wall dado, window, sills, floor, drain etc.
9Labour for boring tube well of required dia. by water jet system through any type of soil strata including hire and labour charges for boring pipes, scaffolding, tools and plants as necessary and taking out them and lowering pipes, strainers, blind pipe etc. and fitting and fixing the same complete including bucket washing and other incidental works in the connection. The tube well should have a minimum 50 mm gap in between the outside of the tubewell pipe and the bore.(a) For depth upto 150 mt for 50 mm dia tube well with top enlargement of 100 mm dia.(i) 50 mm dia. boring etc.
10100 mm dia. boring etc.
11Supply of PVC pipes & fittings Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I).(A) PVC Pipes(i) 50 mm dia.
12(ii) 100 mm dia..
13Supplying PVC strainer of approved make with adapter conforming toI.S.12818 specifications.(i) 50 mm dia.
14Supplying, fitting and fixing steel cutter piece upto 450 mm long with sockets.(i) 80 mm dia.
15Supply of long screw (150 mm long) of TATA make with sockets (TATA make) and jamnut. (i) 40 mm
16Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer(a) 2000 litre capacity
17Supplying, fitting and fixing heavy type bell mouth reducing socket.(i) 50 mm X 100 mm
18Supplying,fitting and fixing check valve (horizontal) G.M. tested to 21 kg per sq. cm.(i) 50 mm
19Supplying,fitting and fixing plug of approved make conforming to I.S. specification.(i) 50 mm
20Supplying, fitting and fixing 300 mm M.S. housing clamp of approved quality.
21M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-incharge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1969 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc.Payment to be made on the basis of calculated weight of structural members only in finished work as per IS specified weight. Payment for gusset, bracket, cleat, rivets, bolts and nuts may be make by adding the actual weight of such items with the weight of finished structural members or 7% of weight for finished structural members weighing not less than 22.5 Kg. / m. or 15 % of weight for finished structal members weighing less than 22.5 Kg. / m. may be increased allow for bracket, cleat, rivet, bolts and nuts etc. and no seperate payment being made for these items, as per direction of Engineer In Charge. The rates are considered for a height of erection 8m. / 2nd floor level from the ground. Add 1.5% extra over the rate for each additional floor or 4m. beyond initiial 8m. or part thereof.I) For structural members of specified sections weighing less than 22.5 Kg./m
22Supplying, fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conforming to IS-15778: 2007 . with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials.(A) For Exposed Work(i) CPVC Pipes Class-2, SDR-13.5(a) 25 mm dia.From Storage Tank to Stand Post.
23Supplying, fitting and fixing alloy iron with brass spindle bib cock / stop cock of approved brand and make, spray painted and tested to 21 kg per sq. cm.(i) 15 mmm.
24Priming one coat to timber or plastered or steel surface, with ready mixed primer of approved quality, including smoothening surface bu sand papering etc.On steel surface
25Painting with best quality synthetic paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface if necessary.(i) Two coats(a) On Steel or other metal surface with super gloss (hi-gloss)
26Supplying fixing commissioning and testing Solar Voltaic Module 335 WP 24 V5 nos.on existing iron frame structure each 2008 x 1002 x 35 mm Monocrystalline Silicon Solar cells laminated between sheet of Ethyline Vinyl Acilate(EVA) and high transmissivity 3 mm tempered glass. Confirming to IEC 61215 (Revised) specifications or equivalent National of International Standards. The power output of the module under STC should be a minimum of 335 W. The operating voltage corresponding to the power output mentioned above should be at least 57.0 Volts. The terminal box IP 65 Protection level on the module should have a provision for opening for replacing module. (Anchor / Panasonic / Tata / Adani make)
27Supplying,Fitting ,Fixing & Installation of Iron Removing Filter Plant Capacity 1500 LPH.IR Media Filter.Working - Downflow,Max Flow Rate- 3 m3 / hr,Working Pressure- 1-3 kg / cm2,Size -14”X65”,Make - Pentair / Vili / others. (BIS Standards & Including 1 Year Warranty)olt.
28Supply and fixing round 2-core 4 sq-mm PVC multi core FR wire for array connecting.
29Supply and fixing MC4 connector for panel loop.
30Earthing with 50 mm (2”) dia G.I. pipe 3.64 mm thick x 3 mts. Long and 1 x 4 SWG G.I. Wire (4 mts. Long) 13mm dia. X 80 mm long G.I. pipe protection (1 mtr. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 mts. Below the ground level & restoring the surface duly rammed.For soft soil.
31Connecting the all equipment to earth busbar including GI (Hot Dip) wire of size as below on wall floor……………… as required and making connection to equipment with bolts, nuts, washers cable lugs as required and mending good damages No. 4 SWG.
32Providing and fixing conductor made of 25 mm dia 300 mm long copper tube having single prong at top with 85 mm dia 3 mm thick copper base plate including holes etc. complete as required.
33Supply, installation testing & lowering of 1.5 HP oil Solar submersible pump motor set complete having suitable discharge as per yield test of well. Submersible cable of 30 mtr 3-core 2.5 sq-mm cable with MOC bar chart and necessary Control panel and Starter as per manufacturer specification. (Mascot / Latteys / CRI / Kirloskar)
34GST
35Labour cess

AI Tender Summary

OUR REF NO 35888957
AUTHORITY Local Bodies
TENDER VALUE 8.81 Lakhs
LAST DATE 28-01-2023
Authority
Authority Name District Magistrate
Work Description Construction And Installation Of 2 Nos. Drinking Water Solar Plant With Ir Purifilter And Submersible Pump Within Balabhut G.P Under Tufanganj-I Block. Activity Code-66536968
Basic Detail
Tender No EO/TFG I/COB15FC/NIT-e7/22-23
Bidding Type Tender
Location
City balabhut
State West Bengal
Key Dates
Publish Date 21 Jan 2023
Submission Date 28 Jan 2023
Open Date 31 Jan 2023
Finance
Tender Value 8.81 Lakhs
Tender Fee Ref. Documents
EMD 17623
Exemption Not Available
Document List
cb9bd8ad-afbd-433b-b290-7621469bb08c.html
BOQ_902325.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jan 21, 2023
11:30 IST

Tender Published

Tender notice published.

Completed
Jan 28, 2023
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jan 31, 2023

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

cb9bd8ad-afbd-433b-b290-7621469bb08c.html

xls

BOQ_902325.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders