Tender For Repair/ Replacement /Maintenance Of Misc Items Including Installation High Mast Lights, Eot Crane Solar Water Heater Systems And Water Heaters At Af Stn Bhisiana, bhisiana-Punjab

Military Engineer Services-MES has published Tender For Repair/ Replacement /Maintenance Of Misc Items Including Installation High Mast Lights, Eot Crane Solar Water Heater Systems And Water Heaters At Af Stn Bhisiana. Submission Date for this Tender is 18-02-2023. Machine Tools Tenders in bhisiana Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

35865589
Corrigendum : Tender For Repair/ Replacement /Maintenance Of Misc Items Including Installation High Mast Lights, Eot Crane Solar Water Heater Systems And Water Heaters At Af Stn Bhisiana
Open Tender
Indian
Punjab
bhisiana
18-02-2023

Tender Details

Tender For Repair / Replacement / Maintenance Of Misc Items Including Installation High Mast Lights, Eot Crane Solar Water Heater Systems And Water Heaters At Af Stn Bhisiana -Supply , Laying , Jointing And Testing In Replacementxlpe Insulated Screened Armoured Heavy Duty Electric Cable With Aluminium Conductor 1100 Volts Grade Of Size 16 Sq Mm 4 Core With Aluminum Thimble Of Same Size Complete All As Specified And Directed By Engineer In Charge. 2 Supply , Laying , Jointing And Testing In Replacement Xlpe Insulated Screened Armoured Heavy Duty Electric Cable With Aluminium Conductor 1100 Volts Grade Of Size 10 Sq Mm 4 Core With Aluminum Thimble Of Same Size Complete All As Specified And Directed By Engineer In Charge. 3 Excavation In Trenches Not Exc. 1.5 M Wide And Notexceeding 1.5M Depth For Foundation Of Poles / Laying Of Cables / Stay / Strut Etc Not Exceeding 10 Sq M On Planand Getting Out In Soft / Loose Soil Complete All As Specified And Directed By Engineer In Charge. 4 Returning, Filling Including Spreading, Leveling Watering And Well Ramming In Layers Not Exceeding 25 Cm Complete All As Specified And Directed By Engineer In Charge. 5 Removing Excavated Material ( Soil ) N.Exc 50M And Depositing Where Directed At A Level Not Exceeding 1.5 Mtr Above The Starting Point Complete All As Specified And Directed By Engineer In Charge. 6 M&L Sandcushioning ( Fazilka Dry Sand ) ) In Trenches / Ducts For Protection Of Ug Cables ( Below, Above And Around The Ug Cable Laid ) Of 23 Cm Spread Thickness ( 8 Cm In Depth Before Laying The Cable And 15 Cm In Depth After Laying The Cable ) And Consolidated ( Punned ) Upto 180Mm Thickness, Complete All As Specified And As Directed.Note : For The Purpose Of Payment, Punned Thickness Of Sand Cushioning Only Will Be Measured. 7 M&L For Brick Protection Cover Of Under Ground Cable By Old Size Bricks Common Burnt Clay Building Bricks Sub Class `B’ Laid Dry And Flat Abutting Each Other With Width Equal To Length Of Brick And Gap Between Adjacent Brick Not Exceeding 10Mm Complete All As Specified And Directed By Engineer In Charge. 8 Supply And Fix In Replacement Led Electronicdriver Suitable For 60 Watt Ledas Light Sources Incluing Taking Down And Old Fitting As Per Repairingrequirement Complete All As Specified & Directed By Engr-In-Charge. 9 Supply And Fix In Replacement Led Electronicdriver Suitable For 45 Watt Ledas Light Sources, Incluing Taking Down And Old Fitting As Per Repairingrequirement Complete All As Specified & Directed By Engr-In-Charge. 10 Supply And Fix In Replacement Led Post Top Lantern With Die Cast Aluminium Spigot, Spun Aluminium, Powder Coated Top Cover Acrylic Diffuser Ip 65 Protection Class Of 25 / 30 Watt Fitted On The Piller With The Help Of Gi Pipe / Pcc Work / Nut Bolts And Connection With 2.5 Sqmm 3 Core Copper Cable Including All Fixing Accessories Complete All As Specified And Directed Engr-In-Charge. 11 M&L In Replacement For Highly Efficient Led Street Light 90 Watt Luminaries New Generation Energy Saving & Environment Friendlywith Lens Made Of Pressure Die Cast Aluminium Alloyhousing Lm24 For Gear And Exturded Alluminium Lamp Housing & Enclouser With Toughened Glass With Ip-66 Of Protection Class, With High Power Leds As Light Source Having Luminous Efficiency Should Be > 80Lm / W With Active Power Factor Correction ( Apfc ) Electronic Gear ( Heat Shrink For Better Heat Transmission ) .It Shall Have Epoxy Powder Coated Grey Finish Phosphochromate Treatment And Operating Voltage Range Should Be Fron 120 Volt To 270 Volt Ac And Frequency Range 50Hz And Suitable For An Ambient Temparature From -40°C To 50 °Cand Humidity Level 10% To 90% Including Connection With Pvc Unsheathed Wirealuminium Conductor 3 X 1.5Sqmm Fitted On Pole / Building With Gi Bracket Of Suitable Size And Connection With 2.5 Sqmm 3 Core Wire Upto Bus Bar Of Oh Line / Pvc Jn Box / Lt Panel / Building For Connection Including Taking Down Of Unserviceable Light Fitting Of Any Type / Size Complete All As Specified And Directed Engr-In-Charge. 12 S&F Pvc Insulated Multi Stranded Copper Conductor Cable 1.5 Sqmm 3 Core, Round Flexible For Connection Of Street Light Fitting With Bus Bar And Flexible Conduit Including Taking Down Unserviceable Cable Of Any Description, Complete All As Specified And As Directed. 13 M&L In Replacement For Highly Efficient Integral Type Led Flood Light 60 Watt New Generation Energy Saving & Environment Friendly Made Of Pressure Die Cast Aluminium With Lens & Enclouser With Toughened Glass With Ip-66 Of Protection Class, With High Power Leds As Light Source Having Luminous Efficiency Should Be > 80Lm / W With Active Power Factor Correction ( Apfc ) Electronic Gear ( Heat Shrink For Better Heat Transmission ) .It Shall Have Epoxy Powder Coated Grey Finish Phosphochromate Treatment And Operating Voltage Range Should Be Fron 120 Volt To 270 Volt Ac And Frequency Range 50Hz And Suitable For An Ambient Temparature From -40°C To 50 °Cand Humidity Level 10% To 90% Including Connection With Pvc Unsheathed Wirealuminium Conductor 3 X 1.5Sqmm Fitted On Pole / Building With Gi Bracket Of Suitable Size And Connection With 2.5 Sqmm 3 Core Wire Upto Bus Bar Of Oh Line / Pvc Jn Box / Lt Panel / Building For Connection Including Taking Down Of U / S Light Fitting Of Any Type / Sizecomplete All As Specified And Directed Engr-In-Charge. 14 M&L For Scraping Down And Removing Of Old Deteroirated Paint From Existing Steel Tubular Poles Above Ground Level, Preparing Surface For Painting, Applying Two Coats Of Aluminium Paint Upto Full Height Of Pole Including Ms Clamps, Gi Brackets, Fittting Etc.Complete All As Directed At Site Including Black And White Strips Of30cms Each Upto 1.5 Mtrs Above Pccwith Black And White Paint And Marking Of Pole No. 2 Mtr Above Pcc , Cutter Shoud Not Be Long Than 6 Cms Height As 16 Cm Dia Circle Around The Marker Number Complete All As Directed By Engr-In-Charge. 15 M&L In Replacement For Time Light Distribution Board Switches Of Capacity 65 Amps Digitial Timer Box Including- ( I ) Contactor Rating 65 Amp 3Pole / 230V, ( Ii ) Digital Timer Programmable Type And ( Iii ) Mcb 65 Amp Tpn, ( Iv ) Copper Wiring Required For Connections ( V ) Selecter Switch. The Timer Box Out Door Type, Mounted On Gi Angle Iron Frameof Size 25X25x4mm Grouted In Cement Concrete, Including Necessary Excavation And Earth Work, Connection Of Lt Ug Cable.Complete All As Specified And Directed By Engr In Charge. 16 M&L For Welding Of Existing Lt Panel / Bus Bar Chamber / Junction Boxes With The Help Of Welding Machine, After Filing Nuts, Bolts, Etc. Includinglocking Arrangement And Applying One Coat Of Synthetic Enamel Ivory Paint ( Smoke Grey ) To Steelsurface After Disconnecting The Electrical Connections And Reconnection The Same At Various Sitesby Taking Safety Precautions After Painting Complete As Specified And Directed By Engr-In-Charge. 17 M&L In Replacement Earthing Complete With Galvanized Steel Earth Plate Electrode 600X600x6 Mm Thick Buried Directly In Ground ( Earth Pit Not Less Than 2.25 Mtr Deep Below Normal Ground Level ) With Top Edge Of The Plate Not Less Than 1.5 Mtr Below Normal Ground Level, The Earth Electrode Surrounded By Adequate Quantity Of Charcoal Dust And Salt To A Packed Thickness Of 15Cm On All Side And Including Connected Toand Includinggi Strip Of Size 32X6mmupto 7.5 Mtrs Long By Means Ofnuts And Bolts, Check Nuts And Washers Of Gi And Connected To Earhing Test Point And Earth Dollyall As Shown In Electrical Plate No 3 Of Mes Ssr Part I And Testing On Completion Includingnecessary Excavation And Earth Work In Any Type Of Soil, Pcc ( 1:3:6 ) Type C1 Chamber, Pre-Cast Rcc Slab 50Mm Thic In Cement Concrete ( 1:2:4 ) , Type B1, Reinforced With Welded Steel Wire Fabric Or Xpm, ( Weight Not Less Than 4 Kg Per Sqm ) With Cast Iron Frame, Funnel With Watering Pipe 20Mm Dia Medium Grade, Wire Mesh And Lugs, Gi Protection Pipe, 15Mm Dia, Light Grade, 7.5 Mtr Long For Protection Of Earth Lead Upto Test Point Etc All As Specified And As Directed. 18 S&F In Replacement Of Pvc Sintex Pole Mounted Junction Box 250X250mm, Having 04 Nos Of Aluminium Bus Bar Mounted On Insulator With The Help Of Nut, Bolts, Clamps Including Single Pole Mcb Of 6 Amps, 2.5 Sqmm Copper Conductors Cable 3 Corefor Connection Of Incoming And Outgoing Cables Complete All As Specified And Directed By Engineer-In Charge 19 S&F In Replacement Of Sheet Metal ( Ms ) Bus Bar Box Single Door, Outdoor Type Weather Proof, Size 300X300x200mm Mounted On Ground With Iron Angles ( 25X25x4mm ) . Having Alluminium Bus Bar 4 Nos, Rated 100Amp All As Specified & Directed By Eng-In-Charge. 20 M&L For Highly Efficient Integral Type Led Flood Light 200 Wattenergy Saving & Environment Friendly Made Of Pressure Die Cast Aluminium With Lens & Enclouser With Toughened Glass With Ip-66 Of Protection Class, With High Power Leds As Light Source Having Luminous Efficiency Should Not Be Less 90 Lumen With Active Power Factor Correction ( Apfc ) Electronic Gear ( Heat Shrink For Better Heat Transmission ) .It Shall Have Epoxy Powder Coated Grey Finish Phosphochromate Treatment And Operating Voltage Range Should Be Fron 120 Volt To 270 Volt Ac And Frequency Range 50Hz And Suitable For An Ambient Temparature From -40°C To 50 °Cand Humidity Level 10% To 90% Including Connection With Pvc Unsheathed Wirecopper Conductor 3 X 4.0 Sqmm Fitted On High Mast Pole Includingconnection And Taking Down Of Old Unserviceable Light Fitting Complete All As Specified And Directed Engr-In-Charge. 21 M&L For Preventive Maintenance Of Existing Eot Crane At Height Of 20 To 22 Metre ( Approx ) From Representative Of Firm As Approved By Ge Including- ( I ) Dismantling Of Hoisting Gear Box, ( Ii ) Drain Of Old Oil, ( Iii ) Cleaning & Greasing Of Gear Box Long Travel And Cross Travel And Refilling Of Fresh Oil ( Iv ) Fill Up Fresh Oil In Gear Box ( V ) Checking Of Hoisting, Long Travel, Cross Travel, Brake Unit , Oiling Of Brake Unit Pins. Greasing Of Long Travel Cross Travel Wheel Bearing, Checking Of Panel Board And Connections , Checking Of Rail Alignment, Checking Of Cross Travel Alignment.Checking And Oiling Greasing Of Wire Rope, Rope Drum, Pedstal Bearings, Load Test Using Dead Weight And Any Minor Defects All Connections Electrical / Mechanical Components, Including Any Minor Repair Deemed To Be Included In The Above Quoted Rate Complete All As Specified And Directed By Eng- In-Charge.Note:- ( I ) All Work Shall Be Executed In Presence Of Contractor, He Will Be Solely Responsible For Safety Of Working Personels At Site. ( Ii ) Contractor Shall Provide Necessary T&P, Safety Equipmentsoil, Grease, Gear Box Oil, Cloth Waste And Minor Spare Required And Any Other Material Required For Executionwill Be Deemed To Be In Quoted Unit Rate. ( Iii ) Approval Of The Firm Shall Be Taken From Ge Before Works Commencement. 22 M&L For Maintenance Of Existing Traffic Control Barrier, Including:- Winding Of 0.5 Hp Electric Motor, Wiring Of Control Panel, Replacement Of Control Switches, Repairing & Greasing Of Mechanical Unit & Gear Box Mechanism, Painting Work & Fabrication Work Required. Including ( I ) 6 Sqmm Xlpe Cable100 Rm For Electric Supply ( Ii ) 2.5 Sqmm 3 Core Copper Cunductor100rm ( Ii ) Excavation Work For Both Supply Cable And Signal Cable Etc.Complete All As Specified And Directed By Engg- In-Charge. Note:-This Job Included All Electrical And Mechanical Items Require To Make The Road Barrier In Serviceable Condition. 23 S&Fpvc Insulated Multi Stranded Copper Conductor Cable 6 Sqmm 4 Core, Round Flexible For Connection With Circuit Including Taking Down Unserviceable Cable Of Any Description, Complete All As Specified And As Directed. 24 S&F Pvc Insulated Multi Stranded Copper Conductor Cable 4 Sqmm 3 Core, Round Flexible For Connection With Circuit Including Taking Down Unserviceable Cable Of Any Description, Complete All As Specified And As Directed. 25 Material And Labour For Contactor Ofcoil Voltage 110 Volt Model Mnx 25 Including Taking Down Unserviceable Contactorof Any Description, Complete All As Specified Anddirected By Engineer In Charge. Make L&T / Havells / C&S 26 Material And Labour For Single Phase Preventor Including Taking Down Unserviceable Preventorof Any Description, Complete All As Specified Anddirected By Engineer In Charge. 27 Material And Labour For Suitable Rocker Holder Of Eot Crane 2 Tonincluding Taking Down Unserviceable Rocket Holderof Any Description, Complete All As Specified Anddirected By Engineer In Charge. . 28 Material And Labour For Iec Style Control Relay , 24 Vdc, 10A And 18 Pins Including Taking Down Unserviceable Iec Style Control Relayof Any Description, Complete All As Specified Anddirected By Engineer In Charge. . 29 M&L In Replacementvfd For 2 Ton Eot Crane 1.5 Kw, 2 Hp Including Connection And Testing Complete All As Specified And Directed By Eng- In-Charge. Make Delta / Schneider Or Equivalentnote:- ( I ) All Work Shall Be Executed In Presence Of Contractor, He Will Be Solely Responsible For Safety Of Working Personels At Site. ( Ii ) Contractor Shall Provide Necessary Oil, Grease, Gear Box Oil, Cloth Waste And Minor Spare Required Willdeemed To Be In Quoted Rate. ( Iii ) The Contractor Shall Replace The Vfd In Control Panel Which Is 20-22 Mtr Height From Ground 30 M&L In Replacementvfd For 2 Ton Eot Crane 2.2 Kw, 3 Hp Including Connection And Testing Complete All As Specified And Directed By Eng- In-Charge. Make Delta / Schneider Or Equivalentnote:- ( I ) All Work Shall Be Executed In Presence Of Contractor, He Will Be Solely Responsible For Safety Of Working Personels At Site. ( Ii ) Contractor Shall Provide Necessary Oil, Grease, Gear Box Oil, Cloth Waste And Minor Spare Required Will Be Deemed To Be In Quoted Rate. ( Iii ) The Contractor Shall Replace The Vfd In Control Panel Which Is 20-22 Mtr Height From Ground 31 M&L In Replacement Ofvfd For 2 Ton Eot Crane5.5 Kw, 7.5Hp Including Connection And Testing Complete All As Specified And Directed By Eng- In-Charge. Make Delta / Schneider Note:- ( I ) All Work Shall Be Executed In Presence Of Contractor, He Will Be Solely Responsible For Safety Of Working Personels At Site. ( Ii ) Contractor Shall Provide Necessary Oil, Grease, Gear Box Oil, Cloth Waste And Minor Spare Required Will Be Deemed To Be In Quoted Rate. ( Iii ) The Contractor Shall Replace The Vfd In Control Panel Which Is 20-22 Mtr Height From Ground 32 M&L For Dismantaling And Taking Down Complete 25 / 35 / 50 Ltr Capacity Geysers From Site And Brought To E / M Store Yard & Refixing The Same After Carrying Out Following Works:- ( I ) Complete Cleaning And De-Scaling Of Inlet And Outlet Connections, Inner Tanks, Fittings, Fixtures & Outlet Pipelines Etc With Suitable Chemical Agent. ( Ii ) Complete Servicing And Maintenance. ( Iii ) Replacement Of Unserviceable Spares As Deemed Necessary Such As Inner Tank, Outer Cover, Inner Assembly, Glasswool, Rubber Gaskets, Nuts, Bolts, Clamps, Etc., Repair Of Minor Leakages If Any By Carrying Out Minor Welding / Brazing. ( Iv ) Complete Testing And To Ensure Proper Functioning & Maintaining Proper Water Temparature Complete All As Specified And Directed.Note:-The Cost For All Spares & Items Such As Heating Element Thermostat, Inner Assembly, Inner Tank, Outer Cover, Etc Shall Be Paid In Respective Items Separately. 33 M&L For Spray Painting To Existing Geysers Of Capacity 25 / 35 Ltrs With Two Coat Of Synthetic Enamel White Paint Over One Coat Red Oxide ( Primer ) Including Scratching Of Old Paint And Making Surface Smooth By Using Filler Etc Complete All As Specified And Directed By Engineer In Charge. 34 M&L For Spray Painting To Existing Geysers Of Capacity 50 Ltrs With Two Coat Of Synthetic Enamel White Paint Over One Coat Red Oxide ( Primer ) Including Scratching Of Old Paint And Making Surface Smooth By Using Filler Etc Complete All As Specified And Directed By Engineer In Charge. 35 S&F In Repair Pvc Connection Pipe 15Mm Size And 45 Cm In Length With Adopter Nuts Of Pvc , Complete All As Specified And As Directed. 36 S&F Geyser Element 2 Kw, Isi Mark ( As Approved ) Including Taking Down / Out Unserviceable One, Complete All As Specified And As Directed By Engineer In Charge. 37 S&F In Replacement Of Thermo Static Switch Of Geyserincluding Taking Down / Out Unserviceable One, Complete All As Specified And As Directed By Engineer In Charge. 38 S&F In Replacement Brass Safety Valve, Isi Marked For Geysers, Including Taking Down / Out Unserviceable One, Complete All As Specified And As Directed By Engineer In Charge. 39 Replacement Of Indicating Bulb Of Geyser Including Taking Down / Out Unserviceable One, Complete All As Specified And As Directed By Engineer In Charge. 40 S&F Pvc Insulated Multi Stranded Copper Conductor Cable 2.5 Sqmm 3 Core, Round Flexible For Connection To Geyser Including Taking Down Unserviceable Cable Of Any Description, Complete All As Specified And As Directed. 41 M&Lfor Grouting The One Set Of Bolts / Anchor / Fastners Of Suitable Size Including Nuts ( One Set Include Four Bolts And Four Nuts ) In Wall Including Taking Down & Refixing The Existing Geysers At Site Any Make & Size And Making Good The Disturbed Surface, Complete All As Specified And Directed. 42 S&F In Replacement Only Outer Body / Cover Suitable For 25 / 35 Ltr Cap Geyser Made Out Of Mild Steel Pre-Treated And Stove Enamelled Sheet Of 18 Swg Complete With Top And Bottom Cover, Rubber Gasket, Stead Screw For Fixing The Top And Bottom Cover To Outer Body Easing Including Two Coat Of White Synthetic Enameled Paint Over One Coat Of Red Oxide Primer, Complete All As Specified And Directed. 43 S&F In Replacement Only Outer Body / Cover Suitable For 50 Ltr Cap Geyser Made Out Of Mild Steel Pre-Treated And Stove Enamelled Sheet Of 18 Swg Complete With Top And Bottom Cover, Rubber Gasket, Stead Screw For Fixing The Top And Bottom Cover To Outer Body Easing Including Two Coat Of White Synthetic Enameled Paint Over One Coat Of Red Oxide Primer, Complete All As Specified And Directed. 44 S&F In Replacement Ofinner Tank Made Of Stainless Steel For Geysers Of Capacity 25 / 35 Ltr Complete All As Specified And Directed. 45 S&F In Replacement Ofinner Tank Made Of Stainless Steel For Geysers Of Capacity 50 Ltr Complete All As Specified And Directed. 46 S&F In Replacement Geyser Inner Assembly Complete As Per Existing Shape / Size As Per Existing For Geyser Of Capacity 25 / 35 / 50 Ltr Having Suitable Numbers Of Slots & Pipes Provisions Complete With Rubber Gasket & Bolts For Fixing Completeall As Specified And Directed. 47 S&F In Replacement Glass Wool Of Minimum Density48 Kg / M3 Of Approved Quality, And Quantity As Per Requirement For Geyser Of Any Capacity Complete All As Specified And Directed. 48 S&F In Replacement Bottom Inspection Cover In Two Pieces Made Of Minimum Size 20 Swg Gi Sheet Suitable For 25 / 50 Ltrs Capacity Geysers Of Any Make, Inclusive Of One Red Oxide Primer Coat, One Under Coat And One Finishing Coat Ofwhite Color Paint Complete On Outer Surface And Inner Surface, Complete All As Specified And Directed. 49 S&F In Replacement Top Cover Made Of Minimum 20 Swg Size Gi Sheet Suitable For 25 / 50 Ltrs Capacity Geysers Of Any Make, Inclusive Of One Red Oxide Primer Coat, One Under Coat And One Finishing Coat Ofwhite Color Spray Paint Complete On Outer Surface And Inner Surface, Complete All As Specified And Directed. 50 Labour Only For Attending Complaints, Carry Out Inspection, Identifying The Fault Of Geyser / Solar Water Heating System At Various Location And Making Geyser / Solar Water Heating System Serviceable After Testing, Complete All As Specified And Directed.Notes: - ( I ) Cost Of Minor Spares Such As Rubber Gaskets, Nuts, Bolts, Clamps, Flanges And Minor Welding / Brazing And Loose Connection Deemed To Be Included In The Quoted Rates. ( Ii ) Cost Of Major Spare Such As Heating Element, Thermostat, Hot Water Pipe, Mcb, Safety Valve, Indicating Bulbwill Be Measured And Paid Under Respective Items Of Schedule. ( Iii ) If Contractor Fail To Attend / Rectify Complaints Within 16 Hrs Of Complaint Time, Recovery At Rs @ 200 Per Day Will Be Done Form Workdone Amount. ( Iv ) Geyser Already Considered Under Item No 32 Here-In-Before Shall Not Be Considred Under This Item. 51 Supply, Laying & Testing Of Tubes ( In Repair ) , Medium Grade Galvanised, 15Mm Bore With All Fitting, Unions, Elbows Etc And Fixed Complete To Walls And Ceilings Or Laid In Floors Including Taking Out Unserviceable, Complete All As Specified And Directed. 52 S&F In Repair Angle Valve 15Mm Bore ( Dia ) , Cast Copper Alloy, Chromium Plated, Screwed Down, High Pressure, Screwed Both Ends For Iron Pipe With Wall Flange, Complete All As Specified And As Directed. 53 S&F In Repairs Bib Tap 15Mm Bore ( Dia ) , 2-In-1, Cast Copper Alloy, Chromium Plated, Suitable For Fixing Of Jet Including Flange Screwed Down, Complete All As Specified And As Directed. 54 M&L Submain Wiring With 2 Runs Of Copper Conductor Pvc Insulated Unsheathed Cable 1100 Volt Grade 4 Sqmm Drawn Through Pvc Conduit Medium Grade Isi Marked 25Mm Dia As Per Is Specification Fixed Concealedin Wall / Ceiling Including Conduit And Conduit Accessories And Incl Provn Of Pvc Insulated 2.5 Sqmm Multistranded Copper Conductor As Earth Continuity Conductor Connected To Earth Dolly All As Specified Including Dismantling Old And Making Good To The Disturbed Surface By Plastering And Two Coat Of Distamper All As Directed At Site.Note : Two Runs Of 4 Sqmm Cable Alongwith One Run Of 2.5 Sqmm Pvc Insulated Unsheathed Copper Conductor As Earth Wire, Conduitand Conduit Accessories Will Be Measured As One Length. 55 S&F In Repairs Metal Plug And Socket Including One No. Mcb 20A Complete All As Specified And Directed By Engr-In-Charge. 56 M&L For Dismantaling And Taking Down Complete Solar Water Heater System Of 300 Lpd Capacity Installed At Single / Double / Triple Storey Bldgs And Re-Fixing The Same After Carrying Out Following Works:- ( I ) Complete Cleaning And De-Scaling Of Inlet And Out Let Connections, Solar Collectors, Glasses, Hot Water Tank, Cold Water Tank, Make Up Tank, Fittings, Fixtures & Pipelines Etc With Suitable Chemical Agent. ( Ii ) Complete Servicing And Maintenance. ( Iii ) Replacement Of Unserviceable Spares As Deemed Necessary Such As Hot Water Tank, Flat Plate Collectors, Rubber Gaskets, Nuts, Bolts, Clamps, Flanges Etc., Repair Of Minor Leakages If Any By Carrying Out Minor Welding / Brazing. ( Iv ) Complete Testing And To Ensure Proper Functioning & Maintaining Minimum Water Temparature I.E. 60°C Complete All As Specified And Directed.Notes :- ( A ) Cost Of Minor Spares Such As Chemical Agents, Rubber Gaskets, Nuts, Bolts, Clamps, Flanges Etc And Minor Welding / Brazing Deemed To Be Included In The Quoted Rates. ( B ) The Cost Of Hot Water Tank, Flat Plate Collectors Shall Be Paid In Respective Items Separately. 57 M&L For Hot Water Tank In Replacement Of Capacity 300 Ltrs Without Heat Exchanger ( Non Pressurized ) Type, Cylindricalshape, Inner Tank Made Of Ss 304L With Inlet, Outlet & Overflow Arrangement & Valves, Duly Insulated With Glass Wool / Rockwool Not Less Than 100Mm Thick Layer & Outer Metallic Body And Including Suitable Electrical Backup ( Heating Elements & Thermostat ) , Sacrificial Anode, Temperature Guage & Make-Up Tank Etc. Complete All As Specified And Directed. The Electrical Back-Up System Should Be Thermostatically Controlled At 50°C For Hard Water And 55°C-60°C For Soft Water. 58 M&L For Hot Water Tank In Replacement Of Capacity 200 Ltrs Without Heat Exchanger ( Non Pressurized ) Type, Cylindricalshape, Inner Tank Made Of Ss 304L With Inlet, Outlet & Overflow Arrangement & Valves, Duly Insulated With Glass Wool / Rockwool Not Less Than 100Mm Thick Layer & Outer Metallic Body And Including Suitable Electrical Backup ( Heating Elements & Thermostat ) , Sacrificial Anode, Temperature Guage & Make-Up Tank Etc. Complete All As Specified And Directed. The Electrical Back-Up System Should Be Thermostatically Controlled At 50°C For Hard Water And 55°C-60°C For Soft Water. 59 M&L In Replacement For Flat Plate Collector Isi Marked In The Standard Size Of 1860Mmx1240mmx100mm ( Minimum Dimensions ) Complete In All Respects Having Fabricated Aluminium Sheet Outer Frame Casing & Back Plate And Toughened Radiation Glass Having Exellent Solar Transmittance, Heat Absorbing Unit Shall Be Consisting Of Copper Sheet Ultrasonic / Laser Welded To Specified Nos Of Copper Tubing Grid, With Selective Black Chrome Or Ultra Selective Sputtered Coating, Absorber Plate Must Be Encased In Not Less Than 50Mm Resin Bonded Insulation & Aluminum Foil For Barrier Against Out-Gassing Complete With End Plates, Collars And Fixing Arrangement With Washer / Rubber Seals / Hose Pipe Connection Etc. Complete All As Specified And Directed 60 Supply, Laying & Testing Of Tubes ( In Repair ) , Medium Grade Galvanised, 20Mm Bore With All Fitting, Unions, Elbows Etc And Fixed Complete To Walls And Ceilings Or Laid In Floors, Complete All As Specified & Directed By Engineer In Charge. 61 Supply, Laying & Testing Of Tubes ( In Repair ) , Medium Grade Galvanised, 25Mm Bore With All Fitting, Unions, Elbows Etc And Fixed Complete To Walls And Ceilings Or Laid In Floors, Complete All As Specified & Directed By Engineer In Charge. 62 Supply And Fixing ( In Repair ) Of Aluminium Cladding With Wire Mesh And Minimum 50Mm Thick Glasswool Of 48 Kg / M3 Density For Hot Water 15 / 20 / 25 Mm Gi Tubing Complete With Fittings And Fixing Materials Complete All As Specified & Directed By Engineer In Charge. 63 S&F In Replacement Toughned Radiation Glass Having Exellent Solar Transmittance ( Minimum 90% ) , Of Minimum 4 Mm Sizethick And Of Standard Size As Per Existing Arrangementof Solar Collector Complete All As Specified & Directed By Engineer In Charge. 64 S&F In Replacement Of Solar Water Heater Temperature Gauge / Thermostat As Per Existing Size Complete All As Specified & Directed By Engineer In Charge. 65 S&F In Replacement Heating Element 5 Kw 230V Ac, 50 Cycle, Triangular / Round Type Isi Marked Complete With Rubber Gasketfor Hot Water Tank Electrical Back Up System Complete All As Specified & Directed By Engineer In Charge. 66 S&F In Replacement Heating Element 2 / 3 Kw 230V Ac, 50 Cycle, Triangular / Round Type Isi Marked Complete With Rubber Gasketfor Hot Water Tank Electrical Back Up System Complete All As Specified & Directed By Engineer In Charge. 67 M&L Submain Wiring With 2 Runs Of Copper Conductor Pvc Insulated Unsheathed Cable 1100 Volt Grade 6 Sqmm Drawn Through Pvc Conduit Medium Grade Isi Marked25mm Dia As Per Is Specification Fixed Concealedin Wall / Ceiling Including Conduit And Conduit Accessories And Incl Provn Of Pvc Insulated 4 Sqmm Multistranded Copper Conductor As Earth Continuity Conductor Connected To Earth Dolly All As Specified Including Dismantling Old And Making Good To The Disturbed Surface By Plastering And Two Coat Of Distamper All As Directed At Site. Note : Two Runs Of 6 Sqmm Cable Alongwith One Run Of 4 Sqmm Pvc Insulated Unsheathedcopper Conductor As Earth Wire, Conduitand Conduit Accessories Will Be Measured As One Length. 68 S&F Vertical Mcb Db Tpn 4 Way Factory Made Ip 54 Protection Class Metal Double Door With 200 Amp Rating Bus Bar 240 / 430V Including Provision For Mounting Mccb Upto 125 Amps Rating Including Taking Out Unserviceable Complete All As Directed By Engr-In-Charge. 69 S&F Mcb Db Spn 8 Way Factory Made Ip 43 Protection Class Metal Double Door With 200 Amp Rating Bus Bar 240 / 430V For Fixing Of Mcbs / Isolators / Rccbs Etc Including Taking Out Unserviceablecomplete All As Specified And Directed. 70 S&F Mcb Db Spn 4 Way Factory Made Ip 43 Protection Class Metal Double Door With 200 Amp Rating Bus Bar 240 / 430V For Fixing Of Mcbs / Isolators / Rccbs Etc Including Taking Out Unserviceable, Complete All As Specified And Directed 71 S&F 3 Pole Mccb 100 Amps 50 Hz 415 V With Rupturing Capacity 16 Ka Etc Including Taking Out Unserviceable, Complete All As Specified And Directed 72 S&F 3 Pole Mccb 125 Amps 50 Hz 415 V With Rupturing Capacity 16 Ka Etc Including Taking Out Unserviceable, Complete All As Specified And Directed 73 S&F Mcbs 240 Volts 10 Ka Finger Proof Terminal, Bi-Connect Termination, Label Holder, 35 Mm² Terminal Capacity, Insulated Sliding Shutter, Large Two Position Dolly, Isi Markedto Be Fixed On Db For Following Item No 74 & 75Note : Db Shall Be Measured And Paid Separately Under Respective Items Of Sch A. 74 All As Per Item No 73 But For Mcb Spn 40 To 63 Amps. 75 All As Per Item No 73 But For Mcb Sp 5 To 32 Amps.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 11-Feb-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 18-02-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 30000.0 /-
Tender Value
Refer document

BOQ Items

NAME OFWORK : REPAIR/ REPLACEMENT/ MAINT OF MISC ITEMS INCLUDING INSTALLATION HIGH MAST LIGHTS, EOT CRANE SOLAR WATER HEATER SYSTEMS AND WATER HEATERS AT AF STN BHISIANA
Sl. No. Item Description
1Supply , laying , jointing and testing in replacementXLPE insulated screened armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 16 Sq mm 4 Core with aluminum thimble of same size complete all as specified and directed by Engineer in Charge.
2Supply , laying , jointing and testing in replacement XLPE insulated screened armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 10 Sq mm 4 Core with aluminum thimble of same size complete all as specified and directed by Engineer in Charge.
3Excavation in trenches not exc. 1.5 m wide and notexceeding 1.5m depth for foundation of poles/laying of cables/stay/strut etc not exceeding 10 Sq m on planand getting out in soft/loose soil complete all as specified and directed by Engineer in Charge.
4Returning,filling including spreading, leveling watering and well ramming in layers not exceeding 25 cm complete all as specified and directed by Engineer in Charge.
5Removing excavated material (soil) n.exc 50m and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engineer in Charge.
6M&L SandCushioning (Fazilka Dry Sand)) in Trenches/Ducts for protection of UG Cables (below, above and around the UG Cable laid) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180mm thickness, complete all as specified and as directed. NOTE : For the Purpose of Payment, punned thickness of Sand Cushioning only will be Measured.
7M&L for Brick protection cover of Under Ground cable by old size bricks common burnt clay building bricks sub class `B’ laid dry and flat abutting each other with width equal to length of brick and gap between adjacent brick not exceeding 10mm complete all as specified and directed by Engineer in Charge.
8Supply and fix in replacement LED electronicdriver suitable for 60 Watt LEDas light sources incluing taking down and old fitting as per repairingrequirement complete all as specified & directed by Engr-in-Charge.
9Supply and fix in replacement LED electronicdriver suitable for 45 Watt LEDas light sources,incluing taking down and old fitting as per repairingrequirement complete all as specified & directed by Engr-in-Charge.
10Supply and fix in replacement LED post top lantern with die cast aluminium spigot,spun aluminium,powder coated top cover acrylic diffuser IP 65 protection class of 25/30 watt fitted on the piller with the help of GI pipe/PCC work/nut bolts and connection with 2.5 sqmm 3 core copper cable including all fixing accessories complete all as specified and directed Engr-in-Charge.
11M&L in replacement for highly efficient LED street light 90 watt luminaries new generation energy saving & environment friendlywith lens made of pressure die cast aluminium alloyhousing LM24 for gear and exturded alluminium lamp housing & enclouser with toughened glass with IP-66 of protection class,with high power LEDs as light source having luminous efficiency should be > 80Lm/w with active power factor correction (APFC) electronic gear (Heat shrink for better heat transmission) .It shall have epoxy powder coated grey finish phosphochromate treatment and operating voltage range should be fron 120 volt to 270 volt AC and frequency range 50Hz and suitable for an ambient temparature from -40°C to 50 °Cand humidity level 10% to 90% including connection with PVC unsheathed wirealuminium conductor 3 x 1.5sqmm fitted on pole/building with GI bracket of suitable size and connection with 2.5 sqmm 3 core wire upto bus bar of OH line/PVC Jn box/ LT panel /building for connection including taking down of unserviceable light fitting of any type/size complete all as specified and directed Engr-in-Charge.
12S&F PVC insulated Multi Stranded Copper Conductor Cable 1.5 Sqmm 3 Core, Round Flexible for connection of Street Light Fitting with Bus Bar and flexible conduit including taking down unserviceable Cable of any description, complete all as specified and as directed.
13M&L in replacement for highly efficient integral type LED flood light 60 watt new generation energy saving & environment friendly made of pressure die cast aluminium with lens & enclouser with toughened glass with IP-66 of protection class,with high power LEDs as light source having luminous efficiency should be > 80Lm/w with active power factor correction (APFC) electronic gear (Heat shrink for better heat transmission) .It shall have epoxy powder coated grey finish phosphochromate treatment and operating voltage range should be fron 120 volt to 270 volt AC and frequency range 50Hz and suitable for an ambient temparature from -40°C to 50 °Cand humidity level 10% to 90% including connection with PVC unsheathed wirealuminium conductor 3 x 1.5sqmm fitted on pole/building with GI bracket of suitable size and connection with 2.5 sqmm 3 core wire upto bus bar of OH line/PVC Jn box/ LT panel /building for connection including taking down of u/s light fitting of any type/sizecomplete all as specified and directed Engr-in-Charge.
14M&L for Scraping down and removing of old deteroirated paint from existing steel tubular poles above ground level,preparing surface for painting,applying two coats of aluminium paint upto full height of pole including MS clamps, GI brackets, fittting etc.complete all as directed at site including black and white strips of30cms each upto 1.5 mtrs above PCCwith black and white paint and marking of pole No. 2 Mtr above PCC ,cutter shoud not be long than 6 cms height as 16 cm dia circle around the marker number complete all as directed by Engr-in-charge.
15M&L in replacement for time light distribution board switches of capacity 65 amps digitial timer box including- (i) contactor rating 65 amp 3pole/230V,(ii) Digital timer programmable type and (iii) MCB 65 Amp TPN,(iv)copper wiring required for connections (v)selecter switch. The timer box out door type,mounted on GI angle iron frameof size 25x25x4mm grouted in cement concrete,including necessary excavation and earth work,connection of LT UG cable.complete all as specified and directed by Engr in charge.
16M&L for Welding of existing LT Panel/bus bar Chamber/Junction boxes with the help of welding machine, after filing nuts,bolts,etc. includinglocking arrangement and applying one coat of synthetic enamel ivory paint(Smoke grey) to steelsurface after disconnecting the electrical connections and reconnection the same at various sitesby taking safety precautions after painting complete as specified and directed by Engr-in-Charge.
17M&L in replacement Earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level,the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15cm on all side and including connected toand includingGI strip of size 32x6mmupto 7.5 mtrs long by means ofnuts and bolts, check nuts and washers of GI and connected to earhing test point and earth dollyall as shown in electrical plate No 3 of MES SSR part I and testing on completion includingnecessary excavation and earth work in any type of soil,PCC(1:3:6)type C1 chamber,pre-cast RCC slab 50mm thic in cement concrete (1:2:4),type B1,reinforced with welded steel wire fabric or XPM,(weight not less than 4 Kg per Sqm) with cast iron frame,funnel with watering pipe 20mm dia medium grade,wire mesh and lugs,GI protection pipe,15mm dia,light grade,7.5 mtr long for protection of earth lead upto test point etc all as specified and as directed.
18S&F in replacement of PVC Sintex Pole Mounted Junction Box 250x250mm, having 04 Nos of aluminium bus bar mounted on insulator with the help of nut,bolts, clamps including single pole MCB of 6 amps, 2.5 sqmm copper conductors cable 3 corefor connection of incoming and outgoing cables complete all as specified and directed by Engineer-in charge
19S&F in replacement of sheet metal(MS) bus bar box single door,outdoor type weather proof, size 300x300x200mm mounted on ground with iron angles(25x25x4mm). Having alluminium bus bar 4 nos, rated 100amp all as specified & directed by Eng-in-charge.
20M&L for highly efficient integral type LED flood light 200 wattenergy saving & environment friendly made of pressure die cast aluminium with lens & enclouser with toughened glass with IP-66 of protection class,with high power LEDs as light source having luminous efficiency should not be less 90 lumen with active power factor correction (APFC) electronic gear (Heat shrink for better heat transmission) .It shall have epoxy powder coated grey finish phosphochromate treatment and operating voltage range should be fron 120 volt to 270 volt AC and frequency range 50Hz and suitable for an ambient temparature from -40°C to 50 °Cand humidity level 10% to 90% including connection with PVC unsheathed wirecopper conductor 3 x 4.0 Sqmm fitted on high Mast pole includingconnection and taking down of old unserviceable light fitting complete all as specified and directed Engr-in-Charge.
21M&L for preventive maintenance of existing EOT crane at height of 20 to 22 Metre (Approx)from representative of firm as approved by GE Including-(i) dismantling of hoisting gear box, (ii) drain of old oil, (iii) Cleaning & Greasing of gear box long travel and cross travel and refilling of fresh oil(iv) Fill up fresh oil in gear box (v) Checking of hoisting, long travel, cross travel, brake unit ,oiling of brake unit pins. greasing of long travel cross travel wheel bearing,checking of panel board and connections ,checking of rail alignment,checking of cross travel alignment.checking and oiling greasing of wire rope, rope drum,pedstal bearings,load test using dead weight and any minor defects all connections Electrical/Mechanical components, Including any minor repair deemed to be included in the above quoted rate complete all as specified and directed by Eng- in-charge.NOTE:- (i) All Work shall be executed in presence of contractor, he will be solely responsible for safety of working personels at site. (ii) Contractor shall provide necessary T&P, safety Equipmentsoil,grease, gear box oil, cloth waste and minor spare required and any other Material required for executionwill be deemed to be in quoted unit rate. (iii) Approval of the firm shall be taken from GE before works commencement.
22M&L for maintenance of existing traffic control barrier,including:- winding of 0.5 HP electric motor,wiring of control panel,replacement of control switches, repairing & greasing of mechanical unit & gear box mechanism,painting work & fabrication work required. including (i) 6 Sqmm XLPE Cable100 RM for Electric supply (ii) 2.5 Sqmm 3 core copper cunductor100RM (ii) Excavation work for both supply cable and signal cable etc.complete all as specified and directed by engg- in-charge. Note:-This job included all electrical and mechanical items require to make the road barrier in serviceable condition.
23S&FPVC insulated Multi Stranded Copper Conductor Cable 6 Sqmm 4 Core, Round Flexible for connection with circuit including taking down unserviceable Cable of any description, complete all as specified and as directed.
24S&F PVC insulated Multi Stranded Copper Conductor Cable 4 Sqmm 3 Core, Round Flexible for connection with circuit including taking down unserviceable Cable of any description, complete all as specified and as directed.
25Material and labour for contactor ofcoil voltage 110 volt model MNX 25 including taking down unserviceable Contactorof any description, complete all as specified anddirected by Engineer in Charge. Make L&T/Havells/C&S
26Material and labour for single phase preventor including taking down unserviceable Preventorof any description, complete all as specified anddirected by Engineer in Charge.
27Material and labour for suitable Rocker holder of EOT Crane 2 tonincluding taking down unserviceable Rocket Holderof any description, complete all as specified anddirected by Engineer in Charge. .
28Material and labour for IEC style control relay , 24 VDC, 10A and 18 pins including taking down unserviceable IEC Style control Relayof any description, complete all as specified anddirected by Engineer in Charge. .
29M&L in replacementVFD for 2 Ton EOT crane 1.5 KW, 2 HP including connection and testing complete all as specified and directed by Eng- in-charge. Make Delta/schneider or EquivalentNOTE:- (i)All work shall be executed in presence of contractor, he will be solely responsible for safety of working personels at site. (ii)contractor shall provide necessary oil,grease, gear box oil, cloth waste and minor spare required willdeemed to be in quoted rate. (iii) The Contractor shall replace the VFD in control panel which is 20-22 Mtr height from ground
30M&L in replacementVFD for 2 Ton EOT crane 2.2 KW, 3 HP including connection and testing complete all as specified and directed by Eng- in-charge. Make Delta/schneider or EquivalentNOTE:- (i)All work shall be executed in presence of contractor, he will be solely responsible for safety of working personels at site. (ii)contractor shall provide necessary oil,grease, gear box oil, cloth waste and minor spare required will be deemed to be in quoted rate. (iii) The Contractor shall replace the VFD in control panel which is 20-22 Mtr height from ground
31M&L in replacement ofVFD for 2 Ton EOT crane5.5 KW, 7.5HP including connection and testing complete all as specified and directed by Eng- in-charge. Make Delta/schneider NOTE:- (i)All work shall be executed in presence of contractor, he will be solely responsible for safety of working personels at site. (ii)contractor shall provide necessary oil,grease, gear box oil, cloth waste and minor spare required will be deemed to be in quoted rate. (iii)The Contractor shall replace the VFD in control panel which is 20-22 Mtr height from ground
32M&L for dismantaling and taking down complete 25/35/50 Ltr capacity geysers from site and brought to E/M store yard & Refixing the same after carrying out following works:- (i)Complete cleaning and de-scaling of inlet and outlet connections, inner tanks, fittings, fixtures & outlet pipelines etc with suitable chemical agent. (ii)Complete servicing and maintenance. (iii) Replacement of unserviceable spares as deemed necessary such as inner tank, outer cover, inner assembly, glasswool, rubber gaskets, nuts, bolts, clamps, etc., repair of minor leakages if any by carrying out minor welding/brazing. (iv)Complete testing and to ensure proper functioning & maintaining proper water temparature complete all as specified and directed. Note:-The Cost for all spares & items such as heating element thermostat, inner assembly, inner tank,outer cover, etc shall be paid in respective items separately.
33M&L for spray painting to existing geysers of Capacity 25/35 Ltrs with two coat of synthetic enamel white paint over one coat red oxide (primer) including scratching of old paint and making surface smooth by using filler etc complete all as specified and directed by Engineer in Charge.
34M&L for spray painting to existing geysers of Capacity 50 Ltrs with two coat of synthetic enamel white paint over one coat red oxide (primer) including scratching of old paint and making surface smooth by using filler etc complete all as specified and directed by Engineer in Charge.
35S&F in repair PVC Connection Pipe 15mm size and 45 Cm in length with Adopter Nuts of PVC , complete all as specified and as directed.
36S&F Geyser Element 2 KW, ISI Mark (as approved) including taking down/out unserviceable One, complete all as specified and as directed by Engineer in Charge.
37S&F in replacement of thermo static switch of geyserincluding taking down/out unserviceable One, complete all as specified and as directed by Engineer in Charge.
38S&F in replacement brass safety valve, ISI marked for geysers, including taking down/out unserviceable One, complete all as specified and as directed by Engineer in Charge.
39Replacement of indicating bulb of geyser including taking down/out unserviceable One, complete all as specified and as directed by Engineer in Charge.
40S&F PVC insulated Multi Stranded Copper Conductor Cable 2.5 Sqmm 3 Core, Round Flexible for connection to geyser including taking down unserviceable Cable of any description, complete all as specified and as directed.
41M&Lfor grouting the one set of bolts/anchor/fastners of suitable size including nuts (one set include four bolts and four nuts)in wall including taking down & refixing the existing geysers at site any make & size and making good the disturbed surface, complete all as specified and directed.
42S&F in replacement only outer body/cover suitable for 25/35 Ltr cap geyser made out of mild steel pre-treated and stove enamelled sheet of 18 SWG complete with top and bottom cover, rubber gasket, stead screw for fixing the top and bottom cover to outer body easing including two coat of white synthetic enameled paint over one coat of red oxide primer, complete all as specified and directed.
43S&F in replacement only outer body/cover suitable for 50 Ltr cap geyser made out of mild steel pre-treated and stove enamelled sheet of 18 SWG complete with top and bottom cover, rubber gasket, stead screw for fixing the top and bottom cover to outer body easing including two coat of white synthetic enameled paint over one coat of red oxide primer, complete all as specified and directed.
44S&F in replacement ofinner tank made of stainless steel for geysers of capacity 25/35 Ltr complete all as specified and directed.
45S&F in replacement ofinner tank made of stainless steel for geysers of capacity 50 Ltr complete all as specified and directed.
46S&F in replacement Geyser inner assembly complete as per existing shape/size as per existing for Geyser of capacity 25/35/50 Ltr having suitable numbers of slots & pipes provisions complete with rubber gasket & bolts for fixing completeall as specified and directed.
47S&F in replacement Glass Wool of minimum density48 Kg/m3 of approved quality, and quantity as per requirement for geyser of any capacity complete all as specified and directed.
48S&F in replacement Bottom inspection cover in two pieces made of minimum size 20 SWG GI sheet suitable for 25/50 Ltrs capacity geysers of any make, inclusive of one red oxide primer coat, one under coat and one finishing coat ofwhite color paint complete on outer surface and inner surface, complete all as specified and directed.
49S&F in replacement Top cover made of minimum 20 SWG size GI sheet suitable for 25/50 Ltrs capacity geysers of any make, inclusive of one red oxide primer coat, one under coat and one finishing coat ofwhite color spray paint complete on outer surface and inner surface, complete all as specified and directed.
50Labour only for attending complaints, carry out inspection, identifying the fault of geyser/solar water heating system at various location and making geyser/solar water heating system serviceable after testing, complete all as specified and directed. Notes: - (i) Cost of minor spares such as rubber gaskets, nuts, bolts, clamps, flanges and minor welding/brazing and loose connection deemed to be included in the quoted rates. (ii) Cost of major spare such as heating element, thermostat, hot water pipe, MCB, safety valve, indicating bulbwill be measured and paid under respective items of schedule. (iii) If contractor fail to attend/rectify complaints within 16 Hrs of complaint time, recovery at Rs @ 200 per day will be done form workdone amount. (iv) Geyser already considered under item no 32 here-in-before shall not be considred under this item.
51Supply, laying & testing of Tubes (in repair), "medium grade" galvanised, 15mm bore with all fitting, unions, elbows etc and fixed complete to walls and ceilings or laid in floors including taking out unserviceable, complete all as specified and directed.
52S&F in repair Angle Valve 15mm bore (dia), Cast Copper Alloy, Chromium Plated, screwed down, high pressure, screwed both Ends for Iron Pipe with Wall Flange, complete all as specified and as directed.
53S&F in repairs Bib Tap 15mm bore (dia), 2-in-1, Cast Copper alloy, Chromium Plated, suitable for fixing of Jet including Flange screwed down, complete all as specified and as directed.
54M&L submain wiring with 2 runs of copper conductor PVC insulated unsheathed cable 1100 volt grade 4 sqmm drawn through PVC conduit medium grade ISI marked 25mm dia as per IS specification fixed concealedin wall/ceiling including conduit and conduit accessories and incl provn of PVC insulated 2.5 Sqmm multistranded copper conductor as earth continuity conductor connected to earth dolly all as specified including dismantling old and making good to the disturbed surface by plastering and two coat of distamper all as directed at site. Note : Two runs of 4 sqmm cable alongwith one run of 2.5 Sqmm PVC insulated unsheathed copper conductor as earth wire, conduitand conduit accessories will be measured as one length.
55S&F in repairs Metal Plug and socket including one No. MCB 20A complete all as specified and directed by Engr-in-Charge.
56M&L for dismantaling and taking down complete solar water heater system of 300 LPD capacity installed at single/double/triple storey bldgs and re-fixing the same after carrying out following works:- (i) Complete cleaning and de-scaling of inlet and out let connections, solar collectors, glasses, hot water tank, cold water tank, make up tank, fittings, fixtures & pipelines etc with suitable chemical agent. (ii) Complete servicing and maintenance. (iii) Replacement of unserviceable spares as deemed necessary such as hot water tank, flat plate collectors, rubber gaskets, nuts, bolts, clamps, flanges etc., repair of minor leakages if any by carrying out minor welding/brazing. (iv) Complete testing and to ensure proper functioning & maintaining minimum water temparature i.e. 60°C complete all as specified and directed. Notes :- (a) Cost of minor spares such as chemical agents, rubber gaskets, nuts, bolts, clamps, flanges etc and minor welding/brazing deemed to be included in the quoted rates. (b)The cost of hot water tank, flat plate collectors shall be paid in respective items separately.
57M&L for hot water tank in replacement of capacity 300 Ltrs without heat exchanger (Non pressurized) type, cylindricalshape, inner tank made of SS 304L with inlet, outlet & overflow arrangement & valves, duly insulated with glass wool/rockwool not less than 100mm thick layer & outer metallic body and including suitable electrical backup (heating elements & thermostat), sacrificial anode, temperature guage & make-up tank etc. complete all as specified and directed. The electrical back-up system should be thermostatically controlled at 50°C for hard water and 55°C-60°C for soft water.
58M&L for hot water tank in replacement of capacity 200 Ltrs without heat exchanger (Non pressurized) type, cylindricalshape, inner tank made of SS 304L with inlet, outlet & overflow arrangement & valves, duly insulated with glass wool/rockwool not less than 100mm thick layer & outer metallic body and including suitable electrical backup (heating elements & thermostat), sacrificial anode, temperature guage & make-up tank etc. complete all as specified and directed. The electrical back-up system should be thermostatically controlled at 50°C for hard water and 55°C-60°C for soft water.
59M&L in replacement for flat plate collector ISI marked in the standard size of 1860mmx1240mmx100mm (minimum dimensions) complete in all respects having fabricated aluminium sheet outer frame casing & back plate and toughened radiation glass having exellent solar transmittance, Heat absorbing unit shall be consisting of copper sheet ultrasonic/laser welded to specified nos of copper tubing grid, with selective black chrome or ultra selective sputtered coating, absorber plate must be encased in not less than 50mm resin bonded insulation & aluminum foil for barrier against out-gassing complete with end plates, collars and fixing arrangement with washer/rubber seals/hose pipe connection etc. complete all as specified and directed
60Supply, laying & testing of Tubes (in repair), "medium grade" galvanised, 20mm bore with all fitting, unions, elbows etc and fixed complete to walls and ceilings or laid in floors, complete all as specified & directed by Engineer in Charge.
61Supply, laying & testing of Tubes (in repair), "medium grade" galvanised, 25mm bore with all fitting, unions,elbows etc and fixed complete to walls and ceilings or laid in floors, complete all as specified & directed by Engineer in Charge.
62Supply and fixing (in repair) of aluminium cladding with wire mesh and minimum 50mm thick glasswool of 48 Kg/m3 density for hot water 15/20/25 mm GI tubing complete with fittings and fixing materials complete all as specified & directed by Engineer in Charge.
63S&F in replacement toughned radiation glass having exellent solar transmittance (minimum 90%), of minimum 4 mm sizethick and of standard size as per existing arrangementof solar collector complete all as specified & directed by Engineer in Charge.
64S&F in replacement of solar water heater temperature gauge/thermostat as per existing size complete all as specified & directed by Engineer in Charge.
65S&F in replacement heating element 5 KW 230V AC, 50 cycle, triangular/round type ISI marked complete with rubber gasketfor hot water tank electrical back up system complete all as specified & directed by Engineer in Charge.
66S&F in replacement heating element 2/3 KW 230V AC, 50 cycle, triangular/round type ISI marked complete with rubber gasketfor hot water tank electrical back up system complete all as specified & directed by Engineer in Charge.
67M&L submain wiring with 2 runs of copper conductor PVC insulated unsheathed cable 1100 volt grade 6 sqmm drawn through PVC conduit medium grade ISI marked25mm dia as per IS specification fixed concealedin wall/ceiling including conduit and conduit accessories and incl provn of PVC insulated 4 Sqmm multistranded copper conductor as earth continuity conductor connected to earth dolly all as specified including dismantling old and making good to the disturbed surface by plastering and two coat of distamper all as directed at site. Note : Two runs of 6 sqmm cable alongwith one run of 4 Sqmm PVC insulated unsheathedcopper conductor as earth wire, conduitand conduit accessories will be measured as one length.
68S&F Vertical MCB DB TPN 4 Way factory made IP 54 protection class metal double door with 200 Amp rating bus bar 240/430V including provision for mounting MCCB upto 125 Amps rating including taking out unserviceable complete all as directed by Engr-in-Charge.
69S&F MCB DB SPN 8 Way factory made IP 43 protection class metal double door with 200 Amp rating bus bar 240/430V for fixing of MCBs/Isolators/RCCBs etc including taking out unserviceablecomplete all as specified and directed.
70S&F MCB DB SPN 4 Way factory made IP 43 protection class metal double door with 200 Amp rating bus bar 240/430V for fixing of MCBs/Isolators/RCCBs etc including taking out unserviceable, complete all as specified and directed
71S&F 3 Pole MCCB 100 Amps 50 Hz 415 V with rupturing capacity 16 KA etc including taking out unserviceable, complete all as specified and directed
72S&F 3 Pole MCCB 125 Amps 50 Hz 415 V with rupturing capacity 16 KA etc including taking out unserviceable, complete all as specified and directed
73S&F MCBs 240 Volts 10 KA finger proof terminal, bi-connect termination, label holder, 35 mm² terminal capacity, insulated sliding shutter, large two position dolly, ISI markedto be fixed on DB for following Item no 74 & 75 Note : DB shall be measured and paid separately under respective items of Sch A.
74All as per Item No 73 but for MCB SPN 40 to 63 Amps.
75All as per Item No 73 but for MCB SP 5 to 32 Amps.