}

Tender For Maintenance Of Various Sports Complexes.Sub Head:- Running Maintenance & Operation Of Internal Electrical Installations, External Lighting, I/C Semi High Mast Lighting, D.G Sets, Substation Equipment And Repairing,Lowering, Lifting Of Submersib, Delhi-Delhi

Delhi Development Authority has published Tender For Maintenance Of Various Sports Complexes.Sub Head:- Running Maintenance & Operation Of Internal Electrical Installations, External Lighting, I/C Semi High Mast Lighting, D.G Sets, Substation Equipment And Repairing,Lowering, Lifting Of Submersib. Submission Date for this Tender is 30-01-2023. Uniform Tenders in Delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

35865242
Corrigendum : Tender For Maintenance Of Various Sports Complexes.Sub Head:- Running Maintenance & Operation Of Internal Electrical Installations, External Lighting, I/C Semi High Mast Lighting, D.G Sets, Substation Equipment And Repairing,Lowering, Lifting Of Submersib
Open Tender
Indian
Delhi
Delhi
30-01-2023

Tender Details

Tender For Maintenance Of Various Sports Complexes.Sub Head:- Running Maintenance & Operation Of Internal Electrical Installations, External Lighting, I / C Semi High Mast Lighting, D.G Sets, Substation Equipment And Repairing, Lowering, Lifting Of Submersible Pumps In Nssc, Jasola, Under Electrical Division-3 - Running Operation & Preventive Maintenance Of Electrical Installations, Home Lighting, External Lighting Internal Lighting And D.G. Set As Per Terms And Conditions Attached By Deploying 1 No. Operator Cum Wireman ( Skilled ) And 1 No. Khallasi In One Shifts ( Total 3 Nos. Operator Cum Wireman And 3 Nos Khallasi ) Etc. As Required. 2 Supplying And Replacement ( Including Deduction Of Cost For Replaced Item ) Of Pvc Insulated Copper Wire Of Following Size In The Existing Surface / Recessed Conduit I / C Connection, Testing Etc. As Required.A ) 1X 1.5 Sq.Mm 3 B ) 1X 2.5 Sq.Mm 4 C ) 1X 4.0 Sq.Mm 5 Supplying And Replacement ( I / C Deduction Of Cost For Replaced Item ) 6 A To 32 A Rating, 240 / 415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. A ) Single Pole 6 B ) Double Pole 7 C ) Triple Pole 8 D ) Triple Pole And Neutral 9 Supply And Replacement ( I / C Deduction Of Cost For Replaced Item ) Of Following Led Lights With All Accessories I / C Connection Interconnection And Testing Etc As Required. ( With Lumens Per Watt>110 ) A ) 20Watt Aluminum Battan ( 1200 Mm Long ) Led Light With Ip :20 Fixed On Surface Of Wall And Roof 10 B ) 15 Watt Fixture ( 300Mmx300mm Long ) Led Light With Ip:20 Fixed On Surface / Recess Of Roof 11 C ) 36 Watt Fixture ( 600Mmx600mm Long ) Led Light With Ip :20 Fixed On Surface / Recess Of Roof 12 D ) 25 Watt Led Pressure Die Cast Aluminium Housing, Toughened Glass Cover With Ip-66 Led Street Luminaries.Led Light Notmorethan25wandnotlesserthan 2750Lux 13 E ) 45 Watt Led Pressure Die Cast Aluminium Housing, Toughened Glass Cover With Ip -66 ( 14 Supplying And Replacement ( I / C Deduction Of Cost For Replaced Item ) Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc As Requireda ) 5 / 6 A Switch 15 B ) 15 / 16 A Switch 16 C ) 3 Pin 5 / 6A Socket Outlet 17 D ) 6 Pin 15 / 16 A Socket Outlet 18 Supplying And Replacement ( Including Deduction Of Cost For Replaced Item ) Of Following Sizes Of Aluminum Conductor Xlpe Insulatedpvc Inner Sheathed Armoured Cable 1.1 Kv Grade Confirming To Is:7098 ( Part-I ) Complete With All Amendments Etc As Required:-A ) 2 X 16 Sq.Mm 19 B ) 4X50 Sq.Mm 20 Supply And Replacement ( Including Deduction Of Cost For Replaced Item ) Of Fan Fixing The Same On Existing Opening With Suitable Nut Bolt Fixture And Connection, Testing, Operating 220 Volts Etc As Reqd. A ) 1200 Mm Ceiling Fan 21 Repairing, Servicing And Calibration Of Ht, Lt Panel And Dehydration Of Transformer Of Following Capacities.A ) De-Hydration And Filtrationof Transformer Oil For 400 Kva With Filter Machine At Site To Maintain The Break Down Value Die Electric Strength Of Oil At Least 50 Kv Including Providing Oil Testing Facility At Site For Transformer Etc As Required Qty. 390 Ltr. 22 A ) Servicing Of 11Kv H.T. Vcb 630 Amp Complete With Cleaning Alignment, Adjustment Of Gaps Between Phases, Lubricating All Moving Parts Adjustment For Smooth Mechanical Operation Etc Complete As Required. 23 B ) Testing And Calibration Of H.T Idmt Relay With Secondary Injection Test Set I / C, Cleaning Servicing Of Contacts Tightening Of Loose Contacts Testing Repair Etc. Complete As Required. 24 C ) Servicing / Overhauling Crompton Make L.T Acb 1000 Amp With Cleaning, Alignment, Adjustment Of Gap Between Phase, Lubricating All Moving Parts Adjustment For Smooth Mechanical Operation Etc Complete As Required. 25 D ) Calibration Of Relays, Ht / Lt Meters, Temperature Meter, Buckles Relays And Servicing Of 11 Kv Vacuum Circuit Breakers Of Ht Panel Kirloskar Make Along With Oiling, Greasing Of All Movable And Fire Mechanism Included Checking Of Contact, Resistance And Measuring The Vacuum Level On The Desired Voltage Level With Respect Each Pole. 26 Servicing And “B” Check Of The 380 Kva ( Cummins Make Model ) From Oem / Authorized Dealer I / C Following Items: A ) Fuel Filter 27 B ) Fuel Water Separator 28 C ) Element Lub Oil Filter 29 D ) Corrosion Inhibitor 30 E ) Strip Test 31 F ) Valvoline Premium Blue 7800 Plus 1 / 20 Ltr 32 G ) Element ( Outer ) 33 H ) Element ( Inner ) 34 I ) Towards The B Check Maintenance Service Charges For Your Cummins Dg Set 35 Servicing And “B” Check Of The 30 Kva ( Kirloskar Make Model ) From Oem / Authorized Dealer I / C Following Items:A ) Engine Oil -5 Litre 36 B ) Fuel Filter Element ( Primary ) 37 C ) Fuel Filter Elment ( Secondary ) 38 D ) Oil Filter 39 E ) Air Filter 40 F ) Koel Care Coolant 41 G ) Radiator Descaling 42 Lifting Of Sub Pump Set Of 3Hp / 5Hp / 7Hpcapacity From Existing Bore Well Along With Existing Gi Pipe, Sub Cable, Cable Holding Clamp And Transportation As Required. 43 Assembling And Lowering Of Submersible Pump Set 3Hp / 5Hp / 7Hp Capacity In The Existing Bore Well Alongwith G.I. Pipe I / C Cable Jointing, Binding Of Cable With G.I. Pipe, Connection & Testing Complete As Required. 44 Supply And Fixing Of Led Flood Light, Led Flood Lightnot More Than 200 W Led And Not Lesser Than 24000 Lux With Main Housing Made Of Pressure Die Casting With Uniform Thickness And Proper Heat Sink Design To Ensure Fast Heat Dissipation. The Leds Should Be Mounted On Mcpcb And Should Be Fixed To The Body With Proper Thermal Conductive Paste To Ensure Quick Transfer Of Heat To Heat Sink. The Luminaire Should Be Designed For L70 For A Minimum 50 K Burning Hours At An Ambient Of 45 Degrees. The Led Should Be Provide With Proper Secondary Lens Assembly To Insure Require Beam Shaping Is Specification. The Secondary Lens Assembly Should Be Mounted Mcpcb With Screws. The Leds Mounted On The Front Side Of The Body Should Be Permanently Cover Fitted With A Clear Toughened Glass. This Ensures The Led Assembly Is Free From Dust / Moisture / Water Entry ( Ip 66 ) . The Ik Rating Should Be > Ik 08. Operating Temperature -10 Degrees To 50 Degrees Celsius.

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 27-01-2023 Corrigendum-1 Date 30-01-2023

Key Value

Document Fees
Refer document
EMD
INR 51984.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail