Agriculture Government Departments Closing in 0 days TDR #35854623

Minor Electrical Repairing Work Related To Campus Lighting And Pump Installtion At Different Position Of Bmf ,Haringhata ,Campus.

Issued by Government Departments · haringhata, West Bengal
Tender Value
Ref. Documents
Estimated cost
Bid Submission
28 Jan 2023
0 days left
EMD
7563
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
haringhata → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Minor Electrical Repairing Work Related To Campus Lighting And Pump Installtion At Different Position Of Bmf , Haringhata , Campus.

BOQ

Name of Work: Minor Electrical Repairing work related to campus lighting and pump installtion at different position of BMF ,Haringhata ,Campus.
Sl. No. Item Description
1PUMP INSTALLATION Supply and installation ofOpen well Submersible pump \"\"Crompton Graves /KSB/Other Approvedmake \" Power: 2 HP,Supply Phase 1,Pipe Size:80mm No of stages :1, Head:11-30 Discharge:315-110 LPM with 12 month warranty
2Supply and fixing 230 V , Submersible DOL Pump Starter Havells/LTLK make , 2HP ,Relay Range13A-20A A
3Supply and fixing imagine technologies Fully Automatic Water Level Controller and Indicator with Corrosion and Rust-Free 6 Carbon Sensor
4Supplying and fixing MCB SS enclosure protection, powder coated provision for with IP-20/30 two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment 4 way
5Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection Legrand make SPN 6-32 A
6Supply of Aluminium Armoured cable Mescab/Polycab/RR make 4 core 16 Sqmm
7Supply of Submersible cable 3 core 10 Sqmm Mescab/Polycab/RR make
8Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed
9Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required 25mm dia
10Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S &F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:ISI medium
11BUS BAR INSTALLATION AT GENARATOR ROOMSupplying & fixing sheet metal (16 SWG) Iron Clad Busbar chambers on angle iron frame on wall, incl. earthing attachment and painting as required –( As per Drawing no. 470 of PWD Specification Book – May 1991) 4 bars Dimension of Cu. bars [85mm long 4 x (2x 40x5)mm 600 A,415 V
12Campus Lighting RenovationSupply and fixing crompton make LED Flood Light 100 W CFS-504-100-57-60D-SL-GL-NSG (Rover Pro)
13Supply and fixing crompton make LED Street Light 60 W TRP-409-60-57-SL-GL-NSG(RAPTOR NEO-1)
14Supply and Fixing Compact Mordern Design Crompton make Bulk Head LED light (STUD) LBHP-10-CDL
15Supply and Fixing Crompton make LED Post Top Lanteen TERRAIN LPTC-40-CDL
16Supplying and fixing MCB SS enclosure protection, powder coated provision for with IP-20/30 two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment 4 way
17Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection Legrand make SPN 6-32 A
18Distribution wiring in 1.1 KV single core stranded \"FR\" PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit \"FR\" (Precision make) incl. necy. fittings as required 3X1.5 Sqmm
19BPTIE AND BMF SHED RENOVATIONSupply and fixing LED tube light Crompton make BRIGHT LINEA CCS-100-20-65-HL2-DP-NWH (20 Watt LED Tube Light)
20Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection Legrand make 40A SP
21Distribution wiring in 1.1 KV single core stranded \"FR\" PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit \"FR\" (Precision make) incl. necy. fittings as required 3X1.5 Sqmm
22Supplying & Fixing GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works 6 Module
23Supply & Fixing 240 V 6 A Modular type switch (Brand approved by EIC) on existing GI Modular type switch board having top cover plate and making necessaryconnections as required
24CABLE SUPPLY AND LAYINGSupply of Aluminium Armoured cable Mescab/Polycab/RR make 4 core 50 Sqmm( Chaf Cutter Panel FSBS )
25Supply of Aluminium Armoured cable Mescab/Polycab/RR make 4 core 16 Sqmm (Gen Set to Pump)
26Laying of one No. cable above 35 sqmm and upto 185 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed
27Supply and fixing Aquaguard Regal RO+UV7Ltr.
28M.S. structural works in roof trusses with tubular sections conforming to IS: 806-1968 & IS: 1161- 1998 cnnected to one another with bracket, gusset cleats as per design, direction of Engineer-in-charge complete including cutting to requisite size, fabrication with necessary metal arc welding conforming to IS: 816- 1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour reqired for the work including all incidental chages such as electricity charges, labour insurance charges etc.i) For trusses spanning up to 12.00 m
29Supply & Installation of Polycarbonate Panel board (1.5 mm) of acast/mitsubishi/ub size:6\" x 3\" to be made such a manner that it can be opened towards side direction for taking maintenance.
30Supply & Fixing of 20 watt LED tube light
3126 Guage Galvanized iron sheet for back panel with one coating of white paint, Make - Aarti / Bansal / Jindal
32Wiring in 1.1 KV grade single core stranded \"FR\" PVC insulated & unsheathed copper wire (Brand approved by EIC) of following sizes in 25mm PVC casing-capping (Precision make) incl. necy. PVC clips, fittings etc.2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm)
33S/F of vinyl eco solvent printing for letter inscripted in Englishuv stabilised excellent to self display. Make - 3M/avery/LG.
34Add GST@ 18% on Rs.317310.47 i.e total amount over item 1.00 to 33.00.
35Add labour welfare Cess @ 1% on Rs 374426.35 i.e total amount over item 1.00 to 34.00 .

AI Tender Summary

OUR REF NO 35854623
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 28-01-2023
Authority
Authority Name Animal Resources Development Department
Work Description Minor Electrical Repairing Work Related To Campus Lighting And Pump Installtion At Different Position Of Bmf , Haringhata , Campus.
Basic Detail
Tender No PBGSBS/ELECT/NIT-38/22-23
Bidding Type Tender
Location
City haringhata
State West Bengal
Key Dates
Publish Date 21 Jan 2023
Submission Date 28 Jan 2023
Open Date 30 Jan 2023
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 7563
Exemption Not Available
Document List
Tendernotice_1.pdf
33e268a1-1119-4a6b-ade5-b12d5119ee24.html
BOQ_900607.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jan 21, 2023
11:30 IST

Tender Published

Tender notice published.

Completed
Jan 28, 2023
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jan 30, 2023

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

Tendernotice_1.pdf

html

33e268a1-1119-4a6b-ade5-b12d5119ee24.html

xls

BOQ_900607.xls

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender