Minor Electrical Repairing Work Related To Campus Lighting And Pump Installtion At Different Position Of Bmf ,Haringhata ,Campus.
Tender Value
Ref. Documents
Estimated cost
Bid Submission
28 Jan 2023
0 days left
EMD
7563
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
haringhata → West Bengal
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Minor Electrical Repairing Work Related To Campus Lighting And Pump Installtion At Different Position Of Bmf , Haringhata , Campus.
BOQ
| Sl. No. | Item Description |
| 1 | PUMP INSTALLATION Supply and installation ofOpen well Submersible pump \"\"Crompton Graves /KSB/Other Approvedmake \" Power: 2 HP,Supply Phase 1,Pipe Size:80mm No of stages :1, Head:11-30 Discharge:315-110 LPM with 12 month warranty |
| 2 | Supply and fixing 230 V , Submersible DOL Pump Starter Havells/LTLK make , 2HP ,Relay Range13A-20A A |
| 3 | Supply and fixing imagine technologies Fully Automatic Water Level Controller and Indicator with Corrosion and Rust-Free 6 Carbon Sensor |
| 4 | Supplying and fixing MCB SS enclosure protection, powder coated provision for with IP-20/30 two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment 4 way |
| 5 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection Legrand make SPN 6-32 A |
| 6 | Supply of Aluminium Armoured cable Mescab/Polycab/RR make 4 core 16 Sqmm |
| 7 | Supply of Submersible cable 3 core 10 Sqmm Mescab/Polycab/RR make |
| 8 | Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed |
| 9 | Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required 25mm dia |
| 10 | Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S &F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:ISI medium |
| 11 | BUS BAR INSTALLATION AT GENARATOR ROOMSupplying & fixing sheet metal (16 SWG) Iron Clad Busbar chambers on angle iron frame on wall, incl. earthing attachment and painting as required –( As per Drawing no. 470 of PWD Specification Book – May 1991) 4 bars Dimension of Cu. bars [85mm long 4 x (2x 40x5)mm 600 A,415 V |
| 12 | Campus Lighting RenovationSupply and fixing crompton make LED Flood Light 100 W CFS-504-100-57-60D-SL-GL-NSG (Rover Pro) |
| 13 | Supply and fixing crompton make LED Street Light 60 W TRP-409-60-57-SL-GL-NSG(RAPTOR NEO-1) |
| 14 | Supply and Fixing Compact Mordern Design Crompton make Bulk Head LED light (STUD) LBHP-10-CDL |
| 15 | Supply and Fixing Crompton make LED Post Top Lanteen TERRAIN LPTC-40-CDL |
| 16 | Supplying and fixing MCB SS enclosure protection, powder coated provision for with IP-20/30 two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment 4 way |
| 17 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection Legrand make SPN 6-32 A |
| 18 | Distribution wiring in 1.1 KV single core stranded \"FR\" PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit \"FR\" (Precision make) incl. necy. fittings as required 3X1.5 Sqmm |
| 19 | BPTIE AND BMF SHED RENOVATIONSupply and fixing LED tube light Crompton make BRIGHT LINEA CCS-100-20-65-HL2-DP-NWH (20 Watt LED Tube Light) |
| 20 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection Legrand make 40A SP |
| 21 | Distribution wiring in 1.1 KV single core stranded \"FR\" PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit \"FR\" (Precision make) incl. necy. fittings as required 3X1.5 Sqmm |
| 22 | Supplying & Fixing GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works 6 Module |
| 23 | Supply & Fixing 240 V 6 A Modular type switch (Brand approved by EIC) on existing GI Modular type switch board having top cover plate and making necessaryconnections as required |
| 24 | CABLE SUPPLY AND LAYINGSupply of Aluminium Armoured cable Mescab/Polycab/RR make 4 core 50 Sqmm( Chaf Cutter Panel FSBS ) |
| 25 | Supply of Aluminium Armoured cable Mescab/Polycab/RR make 4 core 16 Sqmm (Gen Set to Pump) |
| 26 | Laying of one No. cable above 35 sqmm and upto 185 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed |
| 27 | Supply and fixing Aquaguard Regal RO+UV7Ltr. |
| 28 | M.S. structural works in roof trusses with tubular sections conforming to IS: 806-1968 & IS: 1161- 1998 cnnected to one another with bracket, gusset cleats as per design, direction of Engineer-in-charge complete including cutting to requisite size, fabrication with necessary metal arc welding conforming to IS: 816- 1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour reqired for the work including all incidental chages such as electricity charges, labour insurance charges etc.i) For trusses spanning up to 12.00 m |
| 29 | Supply & Installation of Polycarbonate Panel board (1.5 mm) of acast/mitsubishi/ub size:6\" x 3\" to be made such a manner that it can be opened towards side direction for taking maintenance. |
| 30 | Supply & Fixing of 20 watt LED tube light |
| 31 | 26 Guage Galvanized iron sheet for back panel with one coating of white paint, Make - Aarti / Bansal / Jindal |
| 32 | Wiring in 1.1 KV grade single core stranded \"FR\" PVC insulated & unsheathed copper wire (Brand approved by EIC) of following sizes in 25mm PVC casing-capping (Precision make) incl. necy. PVC clips, fittings etc.2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) |
| 33 | S/F of vinyl eco solvent printing for letter inscripted in Englishuv stabilised excellent to self display. Make - 3M/avery/LG. |
| 34 | Add GST@ 18% on Rs.317310.47 i.e total amount over item 1.00 to 33.00. |
| 35 | Add labour welfare Cess @ 1% on Rs 374426.35 i.e total amount over item 1.00 to 34.00 . |
AI Tender Summary
Tender Timeline
Jan 21, 2023
11:30 IST
Tender Published
Tender notice published.
CompletedJan 28, 2023
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedJan 30, 2023
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender