Rural Development Government Departments Closing in 0 days TDR #35846844

Tender For Construction Of Bhakt Nivas For Raje Bageswar Darga At-Village Rukadi Taluka-Hatkanangale Dist-Kolhapur

Issued by Government Departments · kolhapur, Maharashtra
Tender Value
19.66 Lakhs
Estimated cost
Bid Submission
27 Jan 2023
0 days left
EMD
19668
Bank guarantee accepted
Document Fee
2000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
kolhapur → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Construction Of Bhakt Nivas For Raje Bageswar Darga At-Village Rukadi Taluka-Hatkanangale Dist-Kolhapur

BOQ

Name of Work : CONSTRUCTION OF BHAKT NIVAS FOR RAJE BAGESWAR DARGA AT-VILLAGE RUKADI TALUKA-HATKANANGALE DIST-KOLHAPUR
Sl. No. Item Description
1Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 metre beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting excetra complete. - (Lift upto 1.5 metre) By Manual MeansItem / Page No : 1 / 153Specification No : Bd.A.1Spec. Page No : 259
2Excavation for foundation in hard murum including removing the excavated material upto a distance of 50 metre beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting excetra complete. (Lift upto 1.5 metre) By Manual Means Item / Page No : 5 / 153 Specification No : Bd.A.2Spec. Page No : 259
3Providing and laying Cast in situ/Ready Mix, cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailling out water, formwork, laying/ pumping, compacting and curing, excetra complete, with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed, excetra) (using ARTIFICIAL SAND). Item / Page No : 1 / 175 Specification No : Bd.E.1 Spec. Page No : 287-288Additional Specifications : 1. With additional specifications for controlled concrete.2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
4Providing and laying in situ/Ready Mix cement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for reinforced cement concrete work in foundations like raft, strip foundations, grillage and footings of reinforced cement concrete columns and steel stanchions, excetra including bailling out water, formwork, cover blocks, compaction, curing and roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel), excetra complete, with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (using ARTIFICIAL SAND).Item / Page No : 11 / 178Specification No : Bd.F.3,B-7Spec. Page No : 298,38-40Additional Specifications : 1. With additional specifications for controlled concrete.2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
5Providing and laying cast in situ / Ready Mix cement conrete M-20 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete columns as per detailed designs and drawing or as directed, including steel centering, formwork, cover blocks,aying/pumping, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing, excetra complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete.with fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 31 / 179Specification No : Bd.F.5,B-7Spec. Page No : 300,38-40Additional Specifications : 1. With additional specifications for controlled concrete.2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
6Providing and laying cast in situ / Ready Mix cement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for reinforced cement concrete coping to plinth or parapet and sill of doors and windows moulded as per detailed drawings or chamfered as approved by the Engineer including centering, formwork, cover blocks, compacting, finishing and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement, including cover block) Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin excetra with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 23 / 185Specification No : Bd.F.12,B-7Spec. Page No : 304-305,38-40Additional Specifications : 1. With additional specifications for controlled concrete.2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
7Providing second class Burnt Brick masonry with conventional / Indian Standard type bricks in cement mortar 1:6 superstructure including striking joints, racking out joints, watering and scaffolding, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 5 / 197Specification No : Bd.G.5Spec. Page No : 315Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
8Providing and laying cast in situ / Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for reinforced cement concrete beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks,laying/pumping, compaction and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND). Item / Page No : 50 / 181Specification No : Bd.F.6,B-7Spec. Page No : 300-301,38-40Additional Specifications : 1. With additional specifications for controlled concrete.2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
9Providing and laying cast in situ / Ready Mix cement concrete M-20 of trap/ granite / quartzite/ gneiss metal for reinforced cement concrete slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks,laying / pumping, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing, excetra complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 70 / 182Specification No : Bd.F.8,B-7Spec. Page No : 302-303,38-40Additional Specifications : 1. With additional specifications for controlled concrete.2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
10Providing and fixing in position thermo mechnically treated FE-500 steel bar reinforcement of various dias for reinforced cement concrete pile caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardis, copings, fins, arches, excetra as per detailed designs, drawings and schedules including cutting, bendding, hooking the bars, binding with wires or tack welding and supporting as requied complete. (For Ground Floor)Item / Page No : 33 / 188Specification No : Bd.F.17Spec. Page No : 306
11Providing internal cement plaster 12 milimetre thick in a single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 4 / 209Specification No : Bd.L.2Spec. Page No : 368Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
12Providing sand faced plaster externally in cement mortar using approved screened sand in all positions including base coat of 15 milimetre thick in cement mortar 1:4 using waterproofing compound at one killogramme per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment of 6 to 8 milimetre thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days, scaffolding, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 11 / 209Specification No : Bd.L.7Spec. Page No : 369Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
13Providing and laying vitrified matt finish tiles of having size 590 milimetre to 605 milimetre X to 605 milimetre of 8 milimetre to 10 milimetre thickness and confirming to Indian Standard 15622-2006 (Group BIa) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 42 / 217Specification No : Bd.M.12Spec. Page No : 385Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
14Providing and laying vitrified matt finish tiles having size 590 milimetre to 605 milimetre X to 605 milimetre of 8 milimetre to 10 milimetre thickness and confirming to Indian Standard 15622-2006 (Group BIa) of approved make, shade and pattern for dado and skirtingin required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 43 / 217Specification No : Bd.M.12Spec. Page No : 385Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable.
15Providing and applying plastic emulsion paint of approved quality, colour and shade to new surfaces in three coats including scaffolding, preparing the surfaces (excluding primer coat), excetra complete.Item / Page No : 14 / 228 Specification No : Bd.P.6 Spec. Page No : 414
16Providing and applying two coats of textured synthetic paint of approved shade and quality and one coat of primer before applying textured paint including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other materials as required, excetra complete. (For Ground Floor) Item / Page No : 24 / 225Additional Specifications : The work shall be carried out as per instructions of Engineer in charge.
17Providing water proofing treatment to newly laid fully cured concrete slab of terraces by applying first coat of polymer modified semi - viscous paste prepared by mixing polymer of approved make (such as Master Seal 550 / brush bond/ Roff Supercrete / Webercrete / Monobond / Perma shield / Hypercrate / Master Crete M 81) and cement in 1:2 proportion ( one litre polymer : two kilogram cement) or Rohnex water proofing system in two coats ( one kilogram powder, 700 mililitre water and polymer jelly for first coat and one kilogram powder, 500 mililitre water and polymer jelly for second coat) to a neatly cleaned and dust free concrete surface and upto 300 milimetre over parapet wall prepared by removing loose and deposited material with brush and water, laying glass fibre mesh of 10 X 10 specification of approved make over tacky surface of first coat of polymer followed by second coat in transverse direction, laying mechanical protective cover to polymer coating treatment with brick bat coba with burnt broken brick bats laid in cement mortar 1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for three days, applying cement slurry over this layer, joints of brick bats with cement mortar 1:3 admixed with approved water proofing compound and finally top finishing with average 20 milimetre thick layer of same mortar added with polypropylene fibers at 125 gram per bag of cement including finishing the surface smooth with neat cement slurry admixed with approved water proofing compond, Marking finished surface by false squares of 300 milimetre X 300 milimetre, Making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and prapet and curing and covering 10 years Guarantee against leakproofness on court fee stamp paper Rs. 100/- including ponding test excetra completeItem / Page No : 27 / 435Additional Specifications : The work shall be done as per instructions of Engineer in charge.
18Providing and fixing 15 milimetre thick eco-friendly densified edge calcium silicate false ceiling (like aeroltie) of approved texture spintone / cosmos / hexa or equivalent of size 595 milimetre X 595 milimetre in true horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel sections (galvanising at the rate of 12 gram per square metre including both sides) consisting of main “T” runner suitably spaced at joints to get required length and size 24 milimetre X 38 milimetre made from minimum 0.33 milimetre thick sheet, spaced 1200 milimetre center to center and cross “T” of size 24 milimetre X 28 milimetre made of minimum 0.33 milimetre thick sheet to be interlocked at the middle of the 1200 milimetre X 600 milimetre panel to form the grid of size 600 milimetre X 600 milimetre resting on periphery walls / partitions on a perimeter wall angle precoated steel of size 24 milimetre X 24 milimetre X 3000 milimetre made of minimum 0.4 milimetre thick sheet with the help of all plugs at 450 milimetre and laying 15 milimetre thick densified edges calcium silicate ceiling tiles of approved texture (spintone / cosmos / hexa) in the grid, including light fittings, fixtures, smoke detectors excetra, wherever required. Main “T” runners suspended from ceiling with using galvanised iron slotted cleats of size 25 milimetre X 35 milimetre X 1.6 milimetre fixed to ceiling using 12.5 milimetre diameter and 50 milimetre long dash fasteners, 4 milimetre galvanised iron adjustable rods with galvanized steel levels clips of size 85 milimetre X 30 milimetre X 0.8 milimetre, spaced at 1200 milimetre center to center along main “T” bottom exposed with 24 milimetre of all T-sections shall be prepainted with polyester baked paint, for all heights, as per specifications, drawings, excetra complete. (For Ground Floor)Item / Page No : 39 / 238Additional Specifications : The work shall be done as per instructions of Engineer in charge.
19Laboratory testing charges for various materials required for items of work, on the basis of testing frequency and charges fixed by Vigilence and Quality Control Circle, Pune.Item / Page No : 4 / 0Additional Specifications : 1. The amount of laboratory testing charges will be paid to contractor only after submission of the original receipt from the Vigillence and Quality Control Office with the name of work mensioned on it.2. Above / below percentage quoted by the contractor will not be applicable for this item.
20Providing and fixing 90 centimetre X 60 centimetre granite name plate engraving 10 centimetre height letter, figures including painting the letters / figures with approved colour and shade complete.Item / Page No : 12 / 294Specification No : Bd.W.7Spec. Page No : 586-587
21ADD INSURANCE TOWARDS 0.50%Non-Dsr ItemAdditional Specifications : The work shall be carried out as per the instructions of Engineer in-charge.
22ADD G.S.T. 18.0%Non-Dsr ItemAdditional Specifications : The work shall be carried out as per the instructions of Engineer in-charge.

AI Tender Summary

OUR REF NO 35846844
AUTHORITY Government Departments
TENDER VALUE 19.66 Lakhs
LAST DATE 27-01-2023
Authority
Authority Name Rural Development Department
Work Description Construction Of Bhakt Nivas For Raje Bageswar Darga At-Village Rukadi Taluka-Hatkanangale Dist-Kolhapur
Basic Detail
Tender No E TENDER NOTICE NO 75-01/2022-23
Bidding Type Tender
Location
City kolhapur
State Maharashtra
Key Dates
Publish Date 20 Jan 2023
Submission Date 27 Jan 2023
Open Date 30 Jan 2023
Finance
Tender Value 19.66 Lakhs
Tender Fee 2000
EMD 19668
Exemption Not Available
Document List
b7ada297-a841-47c9-bd2e-668544579e2d.html
BOQ_1509207.xls
SBD202223.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jan 20, 2023
11:30 IST

Tender Published

Tender notice published.

Completed
Jan 27, 2023
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jan 30, 2023

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

b7ada297-a841-47c9-bd2e-668544579e2d.html

xls

BOQ_1509207.xls

pdf

SBD202223.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders