Indian Institute Of Science Education And Research-IISER has published Tender For Purchase And Installation Of Various Optical Items. Submission Date for this Tender is 03-02-2023. Screws Tenders in kolkata West Bengal. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 27-Jan-2023 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 03-02-2023 |
Sl. No. | Item Description |
1 | Post Holder made of black-anodized Aluminum having length L=50 mm and thru hole diameter Ø12.7 mm with Spring-Loaded Hex-Locking Thumbscrew and1/4"-20 (M6) Tapped Hole on Bottom. Thepost holders should be designed with a wide, square relief cut that provides two lines of contact for highly stable post mounting.The Post Holders must be compatible with the Metric Table. |
2 | Virtually non-magnetic 303 stainless steel (SS) Optical Post of length L = 75 mm and diameter Ø12.7 mm with one Top-Located M4 Removable Setscrew and one Bottom-Located M6 Tapped Hole. The Posts must be compatible with the Metric Table. |
3 | Post Holder made of black-anodized Aluminum having length L=75 mm and thru hole diameter Ø12.7 mm with Spring-Loaded Hex-Locking Thumbscrew and1/4"-20 (M6) Tapped Hole on Bottom. Thepost holders should be designed with a wide, square relief cut that provides two lines of contact for highly stable post mounting. The Post Holders must be compatible with the Metric Table. |
4 | Ø1" Low-GDD Beam splitter for Second Harmonic of Ultrafast Ti: Sapphire Lasers (reflects 360-440 nm and transmits 700-900 nm). The Group Delay Dispersion (GDD) of the Beam-Splitter should be<20 fs2 Over the Reflected Wavelength Range. It must be coated on one surface such that it has high reflectance of s-polarized light in the second harmonic wavelength range and low reflectance of p-polarized light in the fundamental wavelength range. The coatings are needed to be designed for using at a 56° angle of incidence (AOI) to minimize the reflectance of the fundamental component. |
5 | 36" Long, RG-58 BNC Coaxial Cable (BNC Male to BNC Male) with Cable Outer Diameter ofØ0.2". It should have Tarnish-Resistant Brass Body and Stress-Relief Connectors. The electrical requirements for the cable are 50 ? ± 3 ? Impedance, DC - 4.0 GHz Frequency Range, 500VRMS Working Voltage. |
6 | 60"Long,RG-58 BNC Coaxial Cable (BNC Male to BNC Male) with Cable Outer Diameter of Ø0.2". It should have Tarnish-Resistant Brass Body and Stress-Relief Connectors. The electrical requirements for the cable are 50 ? ± 3 ? Impedance, DC - 4.0 GHz Frequency Range, 500VRMS Working Voltage. |
7 | 120"Long,RG-58 BNC Coaxial Cable (BNC Male to BNC Male) with Cable Outer Diameter of Ø0.2". It should have Tarnish-Resistant Brass Body and Stress-Relief Connectors. The electrical requirements for the cable are 50 ? ± 3 ? Impedance, DC - 4.0 GHz Frequency Range, 500VRMS Working Voltage. |
8 | N-BK7 Plano-Convex Mounted Lens having f = 50 mm and optic diameterØ1.5"withARC: 650-1050 nm (B Coating) to provide<0.5% average reflectance per surface over the specified wavelength range. Thelenses are needed to be mounted inSM1.5compatibleThreaded Mounts. |
9 | Ø31.8 mm Studded Pedestal Base Adapter made of solid 303 stainless steel with 1/4"-20 (M6)-threaded studs which is compatible with Ø1/2" post holders(compatible with Metric table). Its base must be Magnetic to securely hold it in place without clamping to an optical table. |
10 | Clamping Fork with1.24" Long Counterbored Slot and 1/4"-20 (M6) captive screws. The Fork should be made of solid 303 stainless steel and at least be able to create three points of contact with the optical table for high stability. |
11 | 3.5mm Thick, Premium Bandpass Filter with outer diameter Ø25 mm having CWL = 400 ± 8 nm, FWHM = 40 ± 8 nm. The filter should be durable and hard-coated with dielectric coatings on a UV fused silica substrate.Each filter is needed to be housed in a black anodized aluminum ring forblocking OD by limiting scattering. |
12 | Short pass Filter having Outer Diameter Ø1" and Cut-Off Wavelength 600 nm. The filter should bemounted in a black anodized aluminum ringthat is labeled with an arrow indicating the design propagation direction. The filter should be ideal for Raman Spectroscopyand Photometry. |
13 | Annular Obstruction Target having diameter of 50 µm and constant pinhole diameter of 1 mm. It should be made of 0.5 mm thick quartz glass substrate and aperture annulus made of AR coated chrome mask with an optical density ? 6 that minimize back reflections. For Fine Alignment purpose, it is needed to have Ø1"Housing for beingmounted in the Translation Mounts. The obstruction must be ideal for High-Pass Spatial Filtering Applications and should be usable in Pre-Assembled Spatial Filter System. |
14 | Lever-Actuated, Continuously Variable,Post-Mountable Standard Iris with black-anodized Aluminum Housing having Minimum Aperture of Ø1.0mmand Maximum Aperture of Ø25.0 mm. It should have Black Spring Steel Leaves and 8-32 (M4) Threaded Stud at the bottom for Post Mounting. |
15 | Flip Mount Adapter made of black-anodized Aluminum (compatible with Metric table). |
16 | Lens Tissues - 50 Booklets with 25 Sheets per Booklet: Extremely Soft, Premium Grade Sheets Single Sheet Dimension: 4.9" x 2.9" (124 x 73 mm), should meet U.S. Government Lens Tissue Specification A-A-50177B. |