Tender For Repair And Maint To Summer Appliances Such As Air Conditioners, Water Coolers, Desert Cooler, Refrigeratiors, Ac Plants And Voltage Stabilizers Etc At Military Station Fazilka, fazilka-Punjab

Military Engineer Services-MES has published Tender For Repair And Maint To Summer Appliances Such As Air Conditioners, Water Coolers, Desert Cooler, Refrigeratiors, Ac Plants And Voltage Stabilizers Etc At Military Station Fazilka. Submission Date for this Tender is 17-02-2023. Voltage Stabiliser Tenders in fazilka Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

35837553
Corrigendum : Tender For Repair And Maint To Summer Appliances Such As Air Conditioners, Water Coolers, Desert Cooler, Refrigeratiors, Ac Plants And Voltage Stabilizers Etc At Military Station Fazilka
Open Tender
Indian
Punjab
fazilka
17-02-2023

Tender Details

Repair And Maint To Summer Appliances Such As Air Conditioners, Water Coolers, Desert Cooler, Refrigeratiors, Ac Plants And Voltage Stabilizers Etc At Military Station Fazilka

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 10-Feb-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 17-02-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 30000.0 /-
Tender Value
INR 15 Lakhs /-

BOQ Items

Name of Work : Repair and maint to summer appliances such as Air Conditioners, Water Coolers, Desert Cooler, Refrigerators, AC Plants and Voltage Stabilizers etc at Military Station Fazilka
Sl. No. Item Description
1REPAIR TO WATER COOLERS
2Labour for servicing/repairing, of water coolers of capacity 60/80/120/150 Ltr to made functional by oiling, greacing of fan motors and cleaning of water storage tankand cooling coils etc complete all as specified and as directed by Engineer-in-charge. Note :- Spare parts where ever required for replacement shall be measured and paid separately as supply & fixing.
3Disconnecting, dismantling (taking out) unserviceable water coolers of 60/80/120/150 Ltr capacity, transportation from site to contractor"s workshop for replacement existing burnt / unserviceable sealed unit compressor, gas-charging and back after repairing, fixing at site, commissioning and testing complete all as specified and as directed by Engineer-in-charge. Note :- Spare parts where ever required for replacement shall be measured and paid separately as supply & fixing.
4Supply and replacement existing burnt / unserviceable sealed unit compressor of water cooler of capacity 40/80 litres with new sealed unit compressor from original manufacturer /authorized dealer under their exchange scheme (Replacement of old unserviceable compressor with new sealed unit compressor of same capacity and make) including gas charging, commissioning and testing including one year warranty period andetc complete all as specified and as directed by Engineer-in-charge.
5All as per Srl item No. 04(here in before) but capacity 60/120 litres
6All as per Srl item No. 04 (here in before) but capacity 80/150 litres
7M&L for cleaning the unit ofwater cooler of capacity upto 40/80 litres with Nitrogan gas and recharging with appropriate Refrigerant gas complete all as specified and as directed by Engineer-in-Charge. Note :- The type and specification of gas shall be as per manufacturers instructions of equipment and as directed by Engineer-in-Charge.
8All as per Srl item No. 7 (here-in-before) but water cooler capacity 60/120 ltrs
9All as per Srl item No. 7 (here-in-before) but water cooler capacity 80/150 ltrs
10S&F in replacement Starting relay complete of water coolers of capacity 40/40, 40/80, 60/120, 120/150 litres etc complete all as specified and as directed by Engineer-in-charge. Make : Renutrol/Indofoss
11S&F in replacement thermostat switch including plate and screw suitable for water cooler of storage capacity upto 150 litres and making necessary electric connection complete all as specified and as directed by Engineer-in-charge. Make : Indofoss / Denfoss
12S&F as in replacement electric wiring kit suitable for water cooler of any make/ capacity with all connections complete all as specified and as directed by Engineer-in-charge.
13S&F in replacement self closing type cast copper alloy, chromium plated water tap (ISI marked) suitable for water cooler screwed and making necessary connection etc complete all as specified and as directed by Engineer-in-charge.
14S&F in replacement ball brass valve (ISI marked) 15mm bore, high pressure with polythene float and fly nut complete, screwed for iron pipe or brass ferrule etc complete all as specified and as directed by Engineer-in-charge.
15S&F in replacement running capacitor 16 mfd etc complete all as specified and as directed by Engineer-in-charge. Make : Keil/Sharda/Tibcon
16S&F in replacement Starting capacitor 80/100 mfd etc complete all as specified and as directed by Engineer-in-charge. Make : Keil/Sharda/Tibcon
17S&F in replacement Running capacitor 25/36 mfd etc complete all as specified and as directed by Engineer-in-charge. Make : Keil/Sharda/Tibcon
18S&F in replacement cooling coil suitable for water cooler of capacity 60/120 litres complete all as specified and as directed by Engineer-in-charge. Make : USHA / VOLTAS/ SRI RAM
19S&F in replacement new blower motor for water cooler of capacity 80/150 litres etc complete all as specified and as directed by Engineer-in-charge. Make : USHA / VOLTAS/ KHAITAN
20S&F in replacement new blower motor for water cooler of capacity 60/120 litres etc complete all as specified and as directed by Engineer-in-charge. Make : USHA / VOLTAS/ KHAITAN
21S&F in replacement new blower motor for water cooler of capacity 40/80 litres etc complete all as specified and as directed by Engineer-in-charge. Make : USHA / VOLTAS/ KHAITAN
22S&F as in replacement stainless steel tray 1mm thick, for waste waterfor water cooler of capacity 40/80 litres etc complete all as specified and as directed by Engineer-in-charge.
23Material & labour for spray painting the water cooler of storage capacity 60/ 80 litre with one coat of ducco paint over a coat of red oxide primer including preparing the existing painted surface and writing MES / SM No. with black & synthetic enamel paint etc complete all as specified and as directed by Engineer-in-charge.
24Material & labour for spray painting the water cooler of storage capacity upto 120/150 litre with one coat of ducco paint over a coat of red oxide primer including preparing the existing painted surface and writing MES / SM No. with black & synthetic enamel paint etc complete all as specified and as directed by Engineer-in-charge.
25REPAIR TO WINDOW/ SPLIT TYPE AIR CONDITIONERS
26Labour for servicing/repairing, of split/window type Air conditioners of capacity 1.5/2.0TR to made functional by oiling, greecing of fan motors and cleaning of filter and cooling coils etc complete all as specified and as directed by Engineer-in-charge. Note :- Spare parts where ever required for replacement shall be measured and paid separately as supply & fixing.
27Disconnecting, dismantling (taking out) unserviceable split/ window type Air conditioners of capacity 1.5/2.0TR, transportation from site to contractor"s workshop for replacement of existing burnt / unserviceable sealed unit compressor, gascharging and back after repairing, fixing at site, commissioning and testing complete all as specified and as directed by Engineer-in-charge. Note :- Spare parts where ever required for replacement shall be measured and paid separately as supply & fixing.
28Disconnecting, dismantling (taking out) existing burnt/ unserviceable uncut type compressor unit from the AC and provision of new compressor to be got replaced from original manufacturer/authorized dealer under their exchange scheme (Replacement of old unserviceable compressor with new sealed unit compressor of same capacity and make) with renewal warranty of one year with relay terminal box suitable for 1.5 ton capacity window type air conditioner including necessary gas charging, transportation to workshop & backcomplete all as specified and as directed by Engineer-in-charge.
29Disconnecting, dismantling (taking out) existing burnt/ unserviceable uncut type compressor unit from the AC and provision of new compressor to be got replaced from original manufacturer/authorized dealer under their exchange scheme (Replacement of old unserviceable compressor with new sealed unit compressor of same capacity and make) with renewal warranty of one year with relay terminal box suitable for 2 ton capacity window type air conditioner including necessary gas charging, transportation to workshop & backcomplete all as specified and as directed by Engineer-in-charge.
30Disconnecting, dismantling (taking out) existing burnt/ unserviceable uncut type compressor unit from the AC and provision of new compressor to be got replaced from original manufacturer/authorized dealer under their exchange scheme (Replacement of old unserviceable compressor with new sealed unit compressor of same capacity and make) with renewal warranty of one year with relay terminal box suitable for 1.5 ton capacity split type air conditioner including necessary gas charging, transportation to workshop & backcomplete all as specified and as directed by Engineer-in-charge.
31Disconnecting, dismantling (taking out) existing burnt/ unserviceable uncut type compressor unit from the AC and provision of new compressor to be got replaced from original manufacturer/authorized dealer under their exchange scheme (Replacement of old unserviceable compressor with new sealed unit compressor of same capacity and make) with renewal warranty of one year with relay terminal box suitable for 2 ton capacity Split type air conditioner including necessary gas charging, transportation to workshop & backcomplete all as specified and as directed by Engineer-in-charge.
32S&F in replacement double shaft blower fan motor, single phase, 230 volt with fan assembly suitable for 1.5/2.0 ton capacity window AC complete all as specified and as directed by Engineer-in-charge. Make: Khaitan / VOLTAS / USHA
33S&F in replacement knob with screw for AC including making necessary connections complete (as per sample) all as specified and as directed by Engineer-in-charge.
34S&F in replacement running capacitor 36 mfd including making necessary connections and testing complete all as specified and as directed by Engineer-in-charge. Make : Usha / Unistar / BHEL / Ramco
35S&F in replacement thermostat switch with plate and screws suitable for window type air conditioners upto 1.5 ton capacity including making necessary connections and testing complete all as specified and as directed by Engineer-in-charge. Make : Renutrol/ Indofoss
36S&F in replacement over load protector suitable for 1.5/2.0 ton capacity window type air conditioner complete all as specified and as directed by Engineer-in-charge. Make : SRI RAM / Renutrol / Indofoss
37S&F in replacement over load protector suitable for 1.5/2.0 ton capacity split type air conditioner complete all as specified and as directed by Engineer-in-charge. Make : SRI RAM / Renutrol / Indofoss
38S&F in replacement starting relay suitable for Air Conditioner 1.5/2 ton capacity complete all as specified and directed by Engineer-in-Charge.
39S&F in replacement selector switch 3 speed with all connections complete all as specified and as directed by Engineer-in-charge.
40S&F as in replacement electric wiring kit suitable for 1.5/2 ton capacity window/ split type air conditioner with all connections complete all as specified and as directed by Engineer-in-charge.
41S&F in replacement front grill (as per sample kept in GE’s Office) of AC capacity 1.5 /2 ton complete all as specified and as directed by Engineer-in-charge.
42Cleaning the gas system with CO2 Gas and gas charging complete of window/ split type AC all as specified and as directed by Engineer-in-Charge. Note :- The type and specificatin of gas shall be as per manufacturers instructions of equipment and as directed by Engieer-in-Charge.
43Taking down cooling split type air conditioners of 1.5/2.0 Ton capacity for alterations to existing only cooling type air conditioner modifying as cooling & heating system by positioning a module of Hot and Cold air conditioning to the existing and testing the same complete all as specified and as directed by Engineer-in-charge.
44Supply and fixing in replacement PCB remote plate of split AC of capacity 1.5/2.0 TR complete with remote all as specified and as directed by Engineer-in-charge.
45Supply and fixing in replacement of PVC blower suitable for split AC of capacity 1.5/2.0 TR complete with remote all as specified and as directed by Engineer-in-charge.
46REPAIRS TO REFRIGERATORS
47Disconnecting, dismantling (taking out) unserviceable Refrigerators of capacity 165-310 Ltr, transportation from site to contractor"s workshop for replacement of existing burnt / unserviceable sealed unit compressor, gascharging and back after repairing, fixing at site, commissioning and testing complete all as specified and as directed by Engineer-in-charge. Note :- Spare parts where ever required for replacement shall be measured and paid separately as supply & fixing.
48Disconnecting, dismantling (Taking out) existing burnt /unserviceable sealed unit compressor of refrigerator of capacity 165 litres and provision of new sealed unit compressor from manufacturer/authorized dealer under their exchange scheme (Replacement of old unserviceable compressor with new sealed unit compressor of same capacity and make) and fixing, commissioning and testing including one year guarantee and necessary gas charging including transportations to work shop and back etc complete all as specified and as directed by Engineer-in-Charge.
49All as per Srl item No. 48 (here-in-before) but 310 litres capacity
50S&F in replacement thermostat switch suitable for 310/165 ltrs refrigerator complete all as specified and as directed by Engineer-in-Charge. Make : Danfoss/Indofoss
51S&F in replacement type starting relay 1/6 HP to 1/10 HP suitable for refrigerator of capacity 165/286/310 litres including thimbles and screws etc complete all as specified and as directed by Engineer-in-charge. Make : Renutrol/Indofoss
52S&F in replacement over load protector suitable for refrigerator of capacity upto 310/165 ltr etc complete all as specified and as directed by Engineer-in-charge. Make : SRI RAM / Renutrol
53S&F in replacement cooling coil suitable for refrigerator of capacity upto 165 litres complete all as specified and as directed by Engineer-in-charge. Make : GODREJ / VOLTAS/ LG / SAMSUNG
54S&F in replacement Vegetable tray suitable for refrigerator of capacity upto 165 ltr complete all as specified and as directed by Engineer-in-charge.
55S&F in replacement Vegetable tray suitable for refrigerator of capacity upto 286/300 ltr complete all as specified and as directed by Engineer-in-charge.
56S&F in replacement Ice chamber (freezer box) including freezer cover suitable for refrigerator of capacity upto 165 ltr complete all as specified and as directed by Engineer-in-charge.
57S&F in replacement Ice chamber (freezer box) including freezer cover suitable for refrigerator of capacity upto 286/300 ltr complete all as specified and as directed by Engineer-in-charge.
58Cleaning the unit with CO2 Gas and recharging of gas complete of refrigeator capacity 165/200 ltrs complete all as specified and as directed by Engineer-in-Charge. Note :- The type and specification of gas shall be as per manufacturers instructions of equipment and as directed by Engineer-in-Charge.
59Cleaning the unit with CO2 Gas and recharging of gas complete of refrigeator capacity 300/310 ltrs complete all as specified and as directed by Engineer-in-Charge. Note :- The type and specification of gas shall be as per manufacturers instructions of equipment and as directed by Engineer-in-Charge.
60Material & labour for spray painting the refrigerator of capacity 165 litres with one coat of ducco paint over a coat of red oxide primer including preparing the existing painted surface and writing MES / SM No. with black & synthetic enamel paint etc complete all as specified and as directed by Engineer-in-charge.
61Material & labour for spray painting the refrigerator of capacity 310 litres with one coat of ducco paint over a coat of red oxide primer including preparing the existing painted surface and writing MES / SM No. with black & synthetic enamel paint etc complete all as specified and as directed by Engineer-in-charge.
62REPAIR TO DEEP FREEZER
63Disconnecting, dismantling (taking out) unserviceable deep freezers of capacity 200-405 Ltr, transportation from site to contractor"s workshop for replacement of existing burnt / unserviceable sealed unit compressor, gascharging and back after repairing, fixing at site, commissioning and testing complete all as specified and as directed by Engineer-in-charge. Note :- Spare parts where ever required for replacement shall be measured and paid separately as supply & fixing.
64Disconnecting, dismantling (taking out) existing burnt/ unserviceable uncut type compressor unit from Deep freezer of capacity 305/ 405 litres capacity and provision of new compressor to be got replaced from original manufacturer/authorized dealer under their exchange scheme (Replacement of old unserviceable compressor with new sealed unit compressor of same capacity and make) with renewal warranty of one yearincluding necessary fixing, commissioning, testing and gas charging, transportation to workshop & backcomplete all as specified and as directed by Engineer-in-charge.
65Disconnecting, dismantling (taking out) existing burnt/ unserviceable uncut type compressor unit from Deep freezer of capacity 200 litres capacity and provision of new compressor to be got replaced from original manufacturer/authorized dealer under their exchange scheme (Replacement of old unserviceable compressor with new sealed unit compressor of same capacity and make) with renewal warranty of one yearincluding necessary fixing, commissioning, testing and gas charging, transportation to workshop & backcomplete all as specified and as directed by Engineer-in-charge.
66S&F in replacement thermostat switch suitable for 200-405 Ltr deep freezers complete all as specified and as directed by Engineer-in-Charge. Make : Danfoss/Indofoss
67S&F in replacement type starting relay 1/6 HP to 1/10 HP suitable for refrigerator of capacity 200-405 Ltr deep freezers including thimbles and screws etc complete all as specified and as directed by Engineer-in-charge. Make : Renutrol/Indofoss
68S&F in replacement over load protector suitable for 200-405 Ltr deep freezers etc complete all as specified and as directed by Engineer-in-charge. Make : SRI RAM / Renutrol
69S&F in replacement cooling coil suitable for 200-405 Ltr deep freezers complete all as specified and as directed by Engineer-in-charge. Make : GODREJ / VOLTAS/ LG / SAMSUNG
70Cleaning the unit with CO2 Gas and recharging of gas complete of deep Freezers capacity 200 Ltrs complete all as specified and as directed by Engineer-in-Charge. Note :- The type and specification of gas shall be as per manufacturers instructions of equipment and as directed by Engineer-in-Charge.
71Cleaning the unit with CO2 Gas and recharging of gas complete of deep Freezers capacity 305/405 Ltrs complete all as specified and as directed by Engineer-in-Charge. Note :- The type and specification of gas shall be as per manufacturers instructions of equipment and as directed by Engineer-in-Charge.
72Material & labour for spray painting Deep Freezers of capacity 200 Litres with one coat of ducco paint over a coat of red oxide primer including preparing the existing painted surface and writing MES / SM No. with black & synthetic enamel paint etc complete all as specified and as directed by Engineer-in-charge.
73Material & labour for spray painting Deep Freezers of capacity 305/405 Litres with one coat of ducco paint over a coat of red oxide primer including preparing the existing painted surface and writing MES / SM No. with black & synthetic enamel paint etc complete all as specified and as directed by Engineer-in-charge.
74REPAIR TO DESERT COOLERS
75Dismantling all the parts of the desert cooler, taking down desert cooler Motor Kit of cap upto 4000 cumper hour, supply & fixing new desert cooler body made out of GI sheet of 18 gauge duly fitted with 2" thick wood wool pads including one front grill fitted with one piano type 6A switch, three speed selector switch of existing make with all arrangements of inlet pipe for pouring water and wash out valve (hole plugged with nut bolt and washer) for draining out dirty/contaminated water and washing etc complete all as specified and as directed by Engineer-in-charge.
76S&F in replacement vertical pump (tullu pump) for desert cooler including making necessary connections complete all as specified and as directed by Engineer-in-charge. Make: Air King / Khaitan / Bajaj
77S&F in replacement fan motor 400mm sweep including blades and brackets of desert cooler complete all as specified and as directed by Engineer-in-charge. Make: Cool Home / KHAITAN / Crompton / Bajaj
78S&F in replacement fan motor 450mm sweep including blades and brackets of desert cooler complete all as specified and as directed by Engineer-in-charge. Make: Cool Home / KHAITAN / Crompton / Bajaj
79S&F in replacement cooling pad (set of three) of desert cooler (as per sample kept in GE’s Office) of any size complete all as specified and as directed by Engineer-in-charge.
80S&F in replacement PVC white pipe of size 15 mm bore as approved complete all as specified and as directed by Engineer-in-charge.
81S&F in replacement of PVC insulated unarmored copper cable of size3 Core, 40/0.0076 complete all as specified and as directed by Engineer-in-charge. Make : Plaza/Finolex/Paragon
82S&F in replacement running capacitor 4 Mfd oil filled including making necessary connections and testing complete all as specified and as directed by Engineer-in-charge. Make: Usha / Unistar / Tibcon
83Material & labour for spray painting to desert cooler with one coat of synthetic enameled anti corrosive paint using spray machine including preparation of surfaces and writing MES / SM No. with black paint on inner side of water tank etc complete all as specified and as directed by Engineer-in-charge.
84S & F in replacement plug top, 6 Amp, 3 Pin, ISI marked complete all as specified and directed by Engineer-in-Charge.
85S&F in replacement ball brass valve (ISI marked) 15mm bore, high pressure with polythene float and connecting rod suitable for iron pipe or brass ferrule etc complete all as specified and as directed by Engineer-in-charge.
86S&F in replacement PVC connection15mm dia, 450mm long with both endbrass ferrule suitable for GIpipe complete all as specified and as directed by Engineer-in-charge.
87Supply & fixing GI tubing 15mm bore dia alongwith wall/floor including GI fittings such as elbow, sockets,unions clamps complete all as specified and as directed by Engineer-in-charge.
88Supply & fixing brass stop cock suitable for 15mm bore GI pipe complete all as specified and as directed by Engineer-in-charge.
89Replacement outer body of desert cooler of standard size madeGI sheet 1 mm thickness including side Shutters, legs, front grill, Fan motor, tullu pump, as per requirement of PVC pipe with (Selector switch,and piano type switch) accessories, nuts and bolts complete all as specified and directed by Engr-in-Charge.
90REPAIR TO VOLTAGE STABILIZERS
91Dismantling voltage stabilizer of capacity 1 KVA to 6 KVA single phase 240 volt AC of any make and any Size for inspection, necessary repair and replacement of worn out/defective spare parts, reassembling, connecting up, testing etc complete all as directed(Necessary spare parts required for replacement shall be measured and paid for separately as S & F)
92S & F transformer suitable for voltage stabilizer of capacity 3 KVA of existing make and size complete all as specified and as directed
93All as per Srl item here-in-before but capacity 4 KVA
94All as per Srl Item here-in-before but capacity 5 KVA
95All as per Srl Item here-in-before but capacity 6 KVA
96S & F circuit diagram plate suitable for voltage stabilizer of capacity upto 3 KVA of existing make and size complete all as specified and as directed.
97S & F volt meter capacity 0-300 volt AC for stabilizer 3 KVA to 5 KVA complete all as specified and as directed
98S & F out put terminal plate as per existing size and all as directed
99REPAIR/MAINT FOR CEILING/EXHAUST FANS
100Taking down/ dismantling complete ceiling fan of size 1200 mm sweepdown rod with its canopies, shackle, condenser housing with its rubber bushes, split pins, unscrewing the body parts of ceiling fan,cutting the unserviceable winding of starter, rotor and taking out ball bearing, gun metal bush etc. complete to carry out the following repairs:-(a) Removing of burnt out fan winding and re-winding of motor with suitable size of copper enamelled wire, varnishing, heating as specified and directed and re-assembling complete ceiling fan fixing only with old/new spare parts (i.e.) rubber bush of shackle and condenser housing, condenser, gun metal bushes, ball bearing, twin twisted copper cable, etc complete all as specified and directed by Engineer-in-charge. (Note :- 1. Ball bearing, Gun metal bushand condensor are measured and paid separately as S & F rates and minor spares like rubber bush shackle,holder deemed to beinclude in quoted rates). 2.Repair/Rewinding of fan shall be carried out in MES yard to bring adequate winding machine,tools & plants and necessary motor winder at site as directed.
101All as per Item No.100 here-in-before but exhaust fan of size 220/250/300/380/450 mm sweep.
102All as per Item No.100 here-in-before but pedestal/Air circulator fan of size 400/450/600 mm sweep.
103Taking down ceiling fan of 1400 mm sweep by unscrewing nut/bolts from its position and fixing the same to its original place after necessary cleaning, oiling, greasing, servicing/overhauling and replacement of bush, bearing, condenser complete all as specified and directed and writing MES number as as directed by Engr-in-Charge. (Note :1. Bush, condensor, ball bearing are measured and paid separately as S & F rates and minor spares like , rubber bush shackle,holder deemed to be include in quoted rates ) 2.Repair/Servicing of fan shall be carried out in MES yard/User site to bring adequate serviceable condition winding machine,tools & plants and necessary motor winder at site as directed.
104All as per item No 103 here in before but exhuast fan 220/250/300/380/450 mm sweep complete all as specified and directed and marking MES number ass as directed by Engr-in-Charge
105Taking down/ dismantling complete ceiling fan of size 1200/1400 mm sweepdown rod with its canopies, shackle, condenser housing with its rubber bushes, split pins, unscrewing the body parts of ceiling fan, including filling the cavities with filler material and painting of ceiling fan by scraping/removing old spray paint with brush/emery paper and spray painting with two coat of synthetic enamelled paint after reassembling spares for serviceable condition complete all as specified and directed and marking MES number ass as directed by Engr-in-Charge. Note: 1.painting of fan shall be carried out in MES yard/User site to bring adequate winding machine,tools & plants and necessary motor winder at site as directed.
106All as per Item No.105 here-in-before but exhaust fan of size 220/250/300/380/450 mm sweep.
107All as per Item No.105 here-in-before but pedestal/Air circulator fan of size 400/450 mm sweep.
108S & F ball bearing number of 6201/6202/6203/6204 as required complete all as specified and directed. (Make : SKF/NBC).
109S & F gun metal bush as per existing specification and make as per sample and confirming to ISI complete all as specified and directed.
110S&F for Condenser 2/2.5/3.15.4.0 MFD as per existing capacity and make as per sample and confirming to ISI complete all as specified and directed.(Make : Universal/Standard/Jyoti/Usha)
111S&F for PVC holder for condenser housing as per existing capacity and make as per sample and confirming to ISI complete all as specified and directed.
112S&F for rubber bush for shackle with bolt, nut and lock pin suitable for ceiling fan 1200mm/1400mm sweep.
113S&F for twin core twisted copper flexible wire/cable of size 23/0.0076 complete all as specified and directed(Make : Finolex/Nicco/KDK/KEI/Havells/HPL)
114S & F canopy top/bottom with U clamp suitable for ceiling fan 1200/1400mm sweep suitable matching color as exising complete all as specified and directed
115S & F down rod 300 mm long of size 20 mm dia for ceiling fan complete all as specified and directed.
116S & F ceiling fan blades suitable for 1200/1400 mm sweep suitable for exising make & type as per sample complete all as specified and directed.
117S & F Exhasust fan blades suitable for 1200/1400 mm sweep suitable for exising make & type as per sample complete all as specified and directed.
118S & F exhaust fan canopy suitable size as per exising size of fans 220/250/300/380/450 mm suitable to matching color complete all as specified and directed
119S & F exhaust fan Louvers GI/MS/PVC suitable to size as per exising fans 220/250/300/380/450 mmcomplete all as specified and directed
120S & F fan regulator electronic (socket) type, single phase, 230Volt complete all as specified and directed Make: Anchor/Cona and equivalent make
121Material and labour for making hole of size 220/250/300/380/450 mm round/Square as required for exhaust fan vent to using suitable tools without disturbing other surface and make good with cement plaster and exising color white wash/distemper/putty as existing color and surface including grouting bolts, nuts into wall for fixing exhaust fan complete all as specified and directed.
122Supply and fixing fresh air exhuast fan motor double ball bearing medium duty 1440 RPM suitable for fixing in bath room of size 300 mm sweep plastic body single phase including provision of suitable fan blades,canopy, motor holding frame and fixing accessories nut,bolts and washers and necessary grouting arrangement to fix on wall surface complete
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail