Tender For Special Repair To Perimeter Security Light At Af Stn Jammu Under Ge (Af) Jammu, jammu-Jammu And Kashmir

Military Engineer Services-MES has published Tender For Special Repair To Perimeter Security Light At Af Stn Jammu Under Ge (Af) Jammu. Submission Date for this Tender is 11-02-2023. Security Lighting Tenders in jammu Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

35826202
Corrigendum : Tender For Special Repair To Perimeter Security Light At Af Stn Jammu Under Ge (Af) Jammu
Open Tender
Indian
Jammu And Kashmir
jammu
11-02-2023

Tender Details

Tender For Special Repair To Perimeter Security Light At Af Stn Jammu Under Ge ( Af ) Jammu

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 01-Feb-2023 BOQ BOQ 11-02-2023
2 01-Feb-2023 Date Corrigendum 1 Date 11-02-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 48400.0 /-
Tender Value
INR 24.20 Lakhs /-

BOQ Items

Name of Work: SPECIAL REPAIR TO PERIMETER SECURITY LIGHTAT AF STN JAMMUUNDERGE (AF) JAMMU
Sl. No. Item Description
1Taking out of old serviceable / unserviceable PVC under ground LTcable of any size and type fixed on pole, wall or laid in floors, trenches, across road crossing etc ,including taking out of cable covers of precast PCC / RCC slab or brick cover etc setting aside serviceable materialsin safe custody for reuse and or unserviceable materials consider as schedule of credit complete all as specified and as directed. Note:- i). Dismantling of clamps nuts bolts etc, taking out of GI pipe in cable protection also included in quoatedrate in under respective item of this schedule. ii).Cost for making good the disturbed surfaces of floors / walls in cement mortar 1:3 shall deemed to be included in the unit rate quoted . However cost for making good the disturbed surfaces of roads with PCC and hard core filling is out of scope of this work and shall be measured and paid separetely under respective of this schedule.
2Supply, Laying, connecting testing XLPE cable 10 Sqmm 4 corePVC insulated unarmoured and over all sheathed with aluminium conductor heavy duty 1100 volts grade laid/ fixing in wall,trenches, floors, ducts passing through pipe forroad crossing etc complete all as directed by Engr-in-Charge.
3Supply, Laying, connecting testing XLPE cable 16 Sqmm 4 core PVC insulated unarmoured and over all sheathed with aluminium conductor heavy duty 1100 volts grade laid/fixing in wall,trenches, floors, ducts passing through pipe forroad crossing etc complete all as directed by Engr-in-Charge.
4Supply and laying & testing UG cable XLPE Insulated, screened, PVC bedded,wire unarmoured, electric power cables (Heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm, 3.5 core, completeall as specified and directed by Engr-in-Charge.
5Supply and laying & testing UG cable XLPE Insulated, screened, PVC bedded,cable unarmoured, electric power cables (Heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm, 3.5 core, complete all as specified and directed by Engr-in-Charge.
6Supply and laying & testing UG cable XLPE Insulated, screened, PVC bedded,wire armoured, electric power cables (Heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm, 3.5 core, completeall as specified and directed by Engr-in-Charge.
7Supply and laying & testing UG cable XLPE Insulated, screened, PVC bedded,wire armoured, electric power cables (Heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq mm, 3.5 core, completeall as specified and directed by Engr-in-Charge.
8Supply and laying & testing UG cable XLPE Insulated, screened, PVC bedded,wire armoured, electric power cables (Heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm, 3.5 core, completeall as specified and directed by Engr-in-Charge.
9Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr deep in loose / soft soil and getting out for under ground cable / erection of poles, stays etc complete all as specified and as directed.
10Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25 cmcomplete all as specified and as directed.
11Removing of excavated material n, exc 50 m away and depositing where directed at a level n, exc 1.5 m above the starting point complete all as directed.
12Supply and laying of DWC (Double Wall Corrugated) HDPE Pipe, ISI Marked IS 16205 Part-II, of outer dia of 63 mm and inner dia 50 mm with smooth internal and profiled external surface for non pressure under ground cable including all connected accessories like coupler, "O" Ring etc, for protection of cablecomplete all as specified and as directed
13Supply and laying of DWC (Double Wall Corrugated) HDPE Pipe, ISI Marked IS 16205 Part-II, of outer dia of 77 mm and inner dia 63 mm with smooth internal and profiled external surface for non pressure under ground cable including all connected accessories like coupler, "O" Ring etc, for protection of cablecomplete all as specified and as directed
14M&L for PCC 1:4:8 type D-2 using 40mm graded aggregate, mechanically crushed stone for mass filling in polepit and foundation etc including provision of necessary form work to achieve fair finished surfaces complete all as specified and as directed.
15M&L for PCC 1:3:6 type C-1 using 20mm graded crushed stone aggregate as in pole pole foundation, coping, stay pits etc including provision of necessary form work to achieve fair finishes surfaces, complete alal as specified and directed.
16Supply and fixing of four core cable Junction Boxes with terminals` Aluminium busbar,IP 66 "halogen free and weather proof” for outdoor installation (with metric knockouts for cable entry - Black Colour) Cable Size 10 to 35 Sqmm 4 core,Box Dimensions-280 x200 x 98 mmcomplete taking out of loop of cable from ground by neccessary earth work all as spcefied and directed by Engr-in- charge. Make- Hensel/Dowells
17Supply & fixing Indus series Powder coated pressure die cast alluminium compact high power LED floodlight/security lightfittings with heat resistant toughned glass with lense having90 Watt including making electric connections using two run of 2.5 sqmm single core unarmoured aluminium wire from junction box, fixed in repairs,CA No also engaved on street light complete all as specified and as directed by Engr-in-Charge. Note :(i) A certificate from the manufactures for warranty minimum upto 02 years shall be obtained and submitted to the AGE/GE (i) Any touch up of the existing surface due to changing of fittings shall be done by contractor with similar surface finish without extra cost to the department.
18S & Frigid non metalic PVC conduit 25 mm exclusives of boxes but incl all Tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles and pipe hooks etc complete all as specified and as directed by Engr-in-Charge.
19S & F of Cable jointing kit suitable for 1.1 KV grade cable end termination, heat shrinkable type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 25 to70 sq mm complete all as specified and as directed by Engr-in-Charge.
20S & F of Cable jointing kit suitable for 1.1 KV grade cable end termination, heat shrinkable type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 to150 sq mmcomplete all as specified and as directed by Engr-in-Charge.
21Supply & fixing Indus series Powder coated pressure die cast alluminium compact high power LED floodlight/security lightfittings with heat resistant toughned glass with lense having60 Watt including making electric connections using two run of 1.5 sqmm single core unarmoured aluminium wire from junction box, fixed in repairs,CA No also engaved on street light complete all as specified and as directed by Engr-in-Charge. Note :(i) A certificate from the manufactures for warranty minimum upto 02 years shall be obtained and submitted to the AGE/GE (i) Any touch up of the existing surface due to changing of fittings shall be done by contractor with similar surface finish without extra cost to the department.
22Supply, laying or fixing 40 mm bore galvanised iron tubing, light grade with all fittings for passing of cables fixed to pole/wall/laid under floor including all fixing accessories complete all as specified and as directed.
23M & Lcopper wire with two single corePVC insulated, stranded, unsheathed cable copper conductor with size 1.5 Sqmm and drawing through& including Non metallic PVC conduit concealed in wall/ pole including earth continuity conductor of size 1.5 Sqmm PVC insulated unsheathed stranded copper conductor cable and connected to earth dolly to be drawn in concealed PVC conduit including connecting to main board complete all as specified and directed by Engineer-in-Charge.
24M & L for fixingnew street light bracket made out of GI pipe light grade 32 mm bore approx length not less than 120 cm bent to shape including new clamps made of MS flat of size 40x5 mm thick including cutting ,welding ,drilling holes ,nut,bolts washers etc including two coat of aluminium paint over one coat of red oxide primer on MS work complete all as specified and as directed.
25Supply and fixing of Cross arms, bracings, supports,clamps and back plates fabricated from structural steel sections including nuts, bolts, washers,welding, bending cold or hot,drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paintall as specified.
26Supply, install, testing and commission out door type cubical feeder pillar box outer shall made out of 3.15 mm thick MS sheet inner shell made out of 2 mm thich MS sheet and MS angle section 50x50x6 mm on PCC 1:2:4 type B-1 platform 45cm above the ground level and 30 cm below the ground level, frame factory fabricated with front and backopen able double door system complete suitable for 3 phase 4 wire 415 Volt, 50 Hz, Size of panel board- 1.0X0.9X0.5 Mtr, a) TPN, Aluminium bus bar 200 Amps insulated with colour coded heat shrinkable sleeve. b) Incoming MCCB 4 pole 63 Amp 25 KA -01 No c) Out going MCB SP 40 Amps-3 Nos e) Indicator lamps RYB –01 S et .
27Supply, install, testing and commission out door type cubical feeder pillar box outer shall made out of 3.15 mm thick MS sheet inner shell made out of 2 mm thich MS sheet and MS angle section 50x50x6 mm on PCC 1:2:4 type B-1 platform 45cm above the ground level and 30 cm below the ground level, frame factory fabricated with front and backopen able double door system complete suitable for 3 phase 4 wire 415 Volt, 50 Hz, Size of panel board- 1.0X0.9X0.5 m, a) TPN, Aluminium bus bar 300 Amps insulated with colour coded heat shrinkable sleeve. b) Incoming MCCB 4 pole 125 Amp 25 KA -01 No c) Out going MCCB TP 63 Amps 16 KA -1 Nos e) Indicator lamps RYB –01 S et .
28Supplying, installing, testing & commissioning out door type cubical panel board outer shall made out of3.15 mm thick MS sheet including door and inner shell made out of 2 mm thick MS sheet and MS angle section 50x50x6 mm mounted on PCC 1:2:4 type B-1 platform 60 cm aboveand 45 cm below the ground level,frame factory fabricated with front & back openable, double door system and cable alloy (Each door hinged with body at 3 places with body and hinges should be welded with body and door) lockable/open able by Keyshaving chromium plated 19 mm dia fancy lock, “U” type gasket shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, tested at factory approved from CPRI factory fabricatedhaving modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:8623/93 comprising of the following :-
29a) Copper bus bar 400 Amps cap 4 wire fixed on insulator not less than 1.0 mtr long bus bar -1 set b) Incoming MCCB 250 Amps 4 pole 415 Volts AC with thermal magnetic 36 KA, Ics=100%, Icu class-2 front face isolation with positive break indication with double break contacts with spreader and phase barrier complete all as directed. - 1 Nos. (c) Outgoing MCCB 160 Amps 4 pole 415 Volts AC with thermal magnetic 25 KA,with double break contacts with spreader and phase barrier complete all as directed. -1 Nos (d) Outgoing MCCB 63 Amps 4 pole 415 Volts AC with thermal magnetic 16 KA,with double break contacts with spreader and phase barrier complete all as directed. - 1 Nos e) Digital Ammeter 0-500 A of size 96sqmm with selector switch-01 No. f) Digital Volt meter 0-500 V of size 96sqmm with selector switch-01 No g) Indicator Lamp RYB 22.5mm dia LED type 240 volts AC with incoming includin back up protection by 2 Amp MCB RYB with holder-01 set of three.
30h) CT Coils of suitable ratio-01 Set. Note :-(i)The quoted rate shall includes minor items such as lugs, nuts & bolts, washers, top insulators, sleeves, provision of extra holes in bus bar etc. (ii) All internal wiring shall be done with suitable size of PVC insulated solid copper conductor FRLS cable conforming toIS-694. (iii) Panel drawing shall be got approved before placing of orderfrom Engr-in-Charge/GE. (iv)The bus connection for cable from main bus bar to outgoing MCCB will be connected through suitable rating bus bar strip type duly insulated. (vi) The Panel shall be surrounded with 9 inch brick wall upto 0.5 mtr height all around the panel and blank portion between panel and wall shall be filled with PCC 1:2:4incl masonry work leaving ducts for cables complete all as directed.(vii) All MCCBs have Ics= 100% Icu. . .
31Supply, install and erect in true vertical positionsteel tubular swaged poles complete with MS base plate of 6 mm thick of size 300 mm x 300 mm, finial taper plug, pole cap, bolts, nuts and washers and screwed pole made out of FRW MS tubing conforming to IS-2713 (Part-II) 1980 type 410-SP-31 ( 9 meters long ) pole including drilling of holes of required size and Nos for fixing of cross arms, painting with one coat of red oxide primer and two coats of aluminium paint for exposed surfaces and two coats of black bituminous paint for portion embeded in concrete, etc complete all as specified and directed in and incl taking down carefully old deterioiated RCC/steelpole.
32Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.0mm thick buried directly in ground, (Earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connected to and including 4 mm dia galvanised earth lead wire by means of bolts, nuts, check nuts and washers of galvanised standard iron or steel all as specified or indicated in electrical plate no 3 of MES Part-I, including testing on completion including the material and labour of the following :- (a) Excavation and earth work for drilling hole for electrodein any type of soil. (b) PCC pit in cement concrete 1:2:4 type B-1 .c) Precast RCC coverwith suitablehandle 40 mm thickinPCC1:2:4type B-1,reinforced with welded steel wirefabric weighing notless than 1.87 Kg/Sqm.(d) Funnelwithwatering pipe of GI20 mm nominal bore medium grade and copper lugs etc all as specified. (e) 15 mm nominal bore light grade GI protection pipe 5 mtrlongforprotectionof earthing lead from mechanical injury or tempering. (f) Requisite quantity of common salt and charcoal. (g) Testing of earthing.Note : (a) On testing after completionof earthing, ifthe desired earth resistanceisnotobtained,theearthingwill bere-done by the contractor at his own risk and cost to the entire satisfaction of the Engineer-in-Charge. (b) The contractor shall quote his rate considering taking down cost of existing unserviceable earthing.
33SCHEDULE "A" PART-II (Schedule of credit) Credit amount of Rs (Refer schedule of credit) for retrieved material mentioned in Sch "A" Part-II of Tender documents in PDF form will be deducted offline during acceptance of tender of lowest bidder.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail