Military Engineer Services-MES has published Tender For Repair/Maintenance To Summer Appliance And Other Connected Works At Adrde Agra Under Ge I Rnd Delhi. Submission Date for this Tender is 21-02-2023. Air Conditioner Tenders in agra Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

35811367
Corrigendum : Tender For Repair/Maintenance To Summer Appliance And Other Connected Works At Adrde Agra Under Ge I Rnd Delhi
Open Tender
Indian
Uttar Pradesh
agra
21-02-2023

Tender Details

Repair/Maintenance To Summer Appliance And Other Connected Works At Adrde Agra Under Ge I Rnd Delhi

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 01-Feb-2023 Corrigendum01 Date 14-02-2023
2 06-Feb-2023 Corrigendum02 BOQ 14-02-2023
3 14-Feb-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 21-02-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 50000.0 /-
Tender Value
Refer document

BOQ Items

NAME OF WORK : REPAIR/MAINTENANCE TO SUMMER APPLIANCE AND OTHER CONNECTEDWORKS AT ADRDE AGRA UNDER GE I RnD DELHI.
Sl. No. Item Description
1M&L for disconnecting electric connection, taking down/ keep aside the air conditioner (Split/Window)/Water Cooler/Refrigerator/Deep Freezer including stabilizer of any make and capacity,servicing the same as cleaning inside, by mean of cleaning of filter, remove dust from body, tightening of loose nut bolt, washer, rubber gasket and tightening of loose wiring, loose connection, replacement of unserviceable parts, wornout, nutbolt, washers, gasket etc and necessary cutting, welding/soldering works with replacement of rusted body parts with new MS/GI Sheets of suitable size and made functional the equipment fully and re-assembling and re-installation in same/other position and testing complete all as specified and directed. Note: All new spare parts will be measured and paid separately under the respective items.
2M&L for detection and rectification of leakages in gas line by necessary brazingin 1.5 Ton/2.0 Ton window / split type AC/refridgerartor/deep freezer/water cooler of any model and any make and ensuring the complete systems leak proof including checking the system and replacement of required spare parts includingcharging of refrigerant gas R-134A / R 22 or any other refridgerant gas as requiredwith appropriate quantity including testing for smooth functioning and re-assembling and re-installation in same/other position complete all as specified and directed.Note: All new Spare parts, will be measured and paid separately under the respective items.
3M&L for dismantling of unserviceable/wornhermetically sealed unit compressorfrom window /Split type AC and replacement with new one compressor, suitable for existing same model/make of capacity 1.5/2 TRsplit/window type AC including brazing with suction and discharge line, checking the system for leak proof and inclduingcharging of refrigerant gas R-134 A /R 22 in appropriate qty after makingvaccum the complete systemand testing the AC for proper functioning complete all as specified and directed.
4Supply only the following items required in repairs of equipments mentioned againstSer item No 1.00 & 2.00 above. Note : All the repairs shall ensured to be carried out at MES store yard including transportation of equipment shall be contractor"s own arrangment.
5Supply only cooling coil complete with fins made of copper suitable upto 1.5 Ton/2.0 Ton capacity Window/Splittype AC as per existing size complete all as specified and directed.
6Supply only condensing coil complete with fins made of copper suitable upto 1.5 Ton/2.0 Ton capacity Window/Splittype AC as per existing size complete all as specified and directed.
7Supply only fan motor for water cooler upto 150 Ltr capacity complete all as specified and directed.
8Supply only fan blade suitable for AC"s blower/ water cooler motor and all as per sample complete all as specified and directed.
9Supply only condensing coil suitable for water cooler upto 150 Ltr capacity copper as per existing make and model complete all as specified and directed.
10Supply only cooling coil suitable for water cooler upto 150 Ltr capacity copper madeas per existing make and model complete all as specified and directed.
11Supply only water outlet tap made of brass cromium plated for water cooler complete all as specified and directed.
12Supply only liquid line valves copper made for ACs upto 2Ton capacity complete all as specified and directed.
13Supply only refrigerant line valve copper made suitable for ACs upto 2 Ton capacity complete all as specified and directed.
14Supply only foam insulation heavy duty for ACs refrigerant line complete all as specified and directed.
15Supply only capilary tube for water cooler/ refrigerator/AC all as per exiting size complete all as specified and directed.
16Supply only starting/running capacitor 80/100 mfd + / -400 V AC, Suitable for 1.5/2.0 Tonwindow/split type AC complete all as specified and directed.
17Supply only over load Relay complete all as specified and directed.
18Supply only Thermostat switch ( DT 50-1052), suitable for 1.5 Ton/2 Ton split / window type ACcomplete all as specified and directed.
19Supply only Blower/Propeller fan motor Single Phase 230 V AC, 50 Hzas per existing sample for indoor unit complete all as specified and directed.
20Supply only Blower/Propeller fan motorSingle Phase 230 V AC, 50 Hzas per existing sample for outdoor unit complete all as specified and directed.
21Supply only Stainer/Filter (copper) Suitable for window type AC of 1.5/2.0 Ton cooling capacity complete all as specified and directed.
22Supply only ElectronicCircuit plate (PCB)for Split/Window A/C1.5 TR/2 Ton complete all as specified and directed.
23Taking out the unserviceable sealed compressor unit from water cooler andS&F New Sealed compressor unit of existing sample, suitablefor 40/80 Ltr capacity of water cooler replace with newcompressor (duly tested) and checking the complete system for leak proof and including charging of refrigerant gas R-134 ain appropriate quantity and testing for smooth functioning complete all as specified and directed.
24S&F running capacitor for Water Cooler having capacity 40/80 and 150 Litres as per existing sample including taking down unserviceable old one complete all as specified and directed.
25S&F over load Relay for Water Cooler having capacity 40/80 and 150 Litres including taking down old one complete all as specified and directed.
26S&F Float valve of 15mm dia non-metallic for Water Cooler having capacity 40/80 and 150 Litres including taking down old one complete all as specified and directed.
27S&F PVC connectionof size 15mm dia for Water Cooler having capacity 40/80 and 150 Litres including taking down unserviceable old onecomplete all as specified and directed.
28Labour only for collecting split type/ Window type AC of 1.5 TR / 2 TRcooling capacity of any make/model fromexistinglocation /E/M store yard including installation of indoor and outdoor unit where as directed, making hole through the wall for and passing the suction/discharge line and PVC coduit of 25 mm dia, not exceeding 3.5 mtr long in concealed surface of wall for drainage of water occurs due to humidity, making good to disturbed surfaces with cement mortor of ratio1:3 finishing to match existing sameand testing complete all as specified and directed.
29S&F 05 KVA wall mounted type stabilizer for automatic operation single phase naturally air cooled indoor type designed for input variation between 170Vto 285V and with output voltage stabilizer at 230V with accuracy of +/-2.5% completeand taking out old complete all as specified and directed.
30S&F sub main wiring using approved colour coding (Phase-red, Neutral-black, Earth-green) complete with two single core FRLS PVC insulated and unshealthedstranded copper conductor cable 4 Sqmmas current carrying conductor and one run of 4.0 Sqmm as earth contunity conductor, voltage rating 1100 volt, ISI marked drawn in and including concealed PVC conduit ISI marked of dia not less than 25 mm and thickness 2 mm with standard accessories including taking down old one complete all as specified and directed. Note: Two run of single core FRLS PVC cable with one run of earth contunity conductor and PVC conduit shall be measured as one unit.
31S&F Sheet metalenclosure with socket plug top and MCBs single pole with a two pin and earth plug andsocket complete with one single pole MCB of"C" series of capacity 16-32 Ampincluding taking out the old one complete all as specified and directed.
32M&L metal clad Industrial plug top ISI mark 2 pin with earth 250 Voltsincluding taking down old one complete all as specified and directed.
33M&L Metal clad Industrial socketISI mark with earth 250 Voltsincluding taking down old one complete all as specified and directed.
34M & L PVC insulated copper cable 3 core 2.5 sqmm,AC 1100/660 volt including taking down unserviceable cable complete all as specified and directed.
35M&L for removing the Desert Cooler from the site and re-fixing after cleaning the Desert Cooler body from inside and outside using sand paper to make the smooth surface and painting two coat of synthetic enamelled paint over a coat of red oxide primer as per exiting colour outside and inside the cooler, including oiling and greasing of fan kit, water pump motor complete all as specified and directed.
36S&F new wooden wool pad, set of three Nos, covered by GI wire mesh suitable for desertcooler including taking out the old unserviceable exiting pad complete all as specified and directed.
37M&L in replacement of old unserviceable water pumping kit (with pump) of Desert Cooler (ISI marked) single phase, 220 AC, 15to 18 watt suitable for Desert Cooler complete all as specified and directed.
38Taking down carefully unserviceable fresh air fan (Fan kit) from desert cooler and supply and fixing new fresh air fan kit 220 Volts single phase as per exiting sample/ size and fixing in same position by providing new nut, bolts, washer, MS frame/side arms and rubber pads etc including testing complete all as specified and directed.
39Taking out existing unserviceable motor of Desert Cooler any size of make, rewinding with super enamelled copper winding wire of same size bush, bearing, shaft and refixing in the same position complete all as specified and directed.
40M&L for replacement of 3 pin plug top 5 Amp 230 V AC for connection lead of Desert Cooler complete all as specified and directed.
41M&L for replacement of steel multi wing fan blade set of best quality as per exiting type and size suitable for Desert Cooler complete all as specified and directed.
42S&F in replacement of Desert Cooler body of size 30" x 30" x 35" complete with both side panels, front panel, side arms, tank, frontgrill made of 1 mm thick PGI sheet etc including fixing the exiting fan kit & Pump motor received from old unserviceable Desert Cooler including all electrical connections, testing and commisioning complete all as specified and directed.
43Taking down ceilling fan/exhaust/air circulating fan of any size or make by disconnecting electric connection and removing from site for rewinding, servicing, painting of fans and refixing the same position complete all as specified and directed.
44Cleaning, washing, greasing, oiling and varnishing of ceiling fan of any size and make complete all as specified and directed.
45M&L for opening and rewinding with super enamelled copper winding wire of existing size of ceiling fan 1200/1400 mm sweep including transportation complete all as specified and directed.
46All as per item Ser No.34.00 above but for exhaust fans of any size (200mm/250mm/450 mm) sweep.
47M&L for replacement of defective ball bearing for ceilling fan of 1200/1400 mm sweep size complete all as specified and directed.
48M&L for replacement of defective capacitor of size 2.5/3.5 mfd for any type of fans suitable for 250 V including making connection complete all as specified and directed.
49M&L for replacement of flexible copper conductor cable 3 core PVC insulated & PVC sheathed 1100 Volts grade size of cable 23/0.0076 complete all as specified and directed.
50M&L for painting of ceiling fans any make of size upto 1400 mm at site with one coat of synthetic enamel paint (1st quality) of approved make by spray gun machine including, filling cavities with filler after preparation of surface and writing letter as per existing such as (MES AC12345) with black synthetic enamel paint, 1" high on both sides of fans complete all as specified and directed.
51S&F in replacement of PVC canpoy suitable for 1200/1400 mm sweep ceilling fan complete all as specified and directed.
52Takingdownexisting unserviceable/old point wiring surface /batten includingfitting fixtures ,ceiling roses, pendant/angle holders, regulators, sockets,switches andPVC conduitcomplete all as specified and directed
53Material and labour for point wring ,using approved colour coding (Phase-red,Neutral-black,Earth-green) complete with FRLS PVC insulated and unshealthedstranded copper conductor cable 1.5 sqmm single coreconforming to IS 694 including medium duty concealed unplasticised PVC conduit conforming to IS 9537(part-3) and ISI marked not less than 20 mm dia with concealed in wall pressed steel terminal box of not less than 2 mm thick of required size including painting terminal boxs inside and outside with two coat of synthetic enamle paint over one coat of red oxide primerwith top cover3 mm thickbakelight laminated sheetwith brass screws and Cup washer with all assessories including FRLS PVC insulated and unshealthedstranded copper conductor cable 1.5 sqmm single core in green colouras earth wireconnected to earth dolly complete all as specified and directed for as under:-
54One light/fan/exhaust fan point/call bell point controlled by 1 No,one way 5/6 Amp switch.
55One 3 pin /5 pin socket outlet 5 Amp controlled by 1 No one way 5/6 Amp switch on same board along with other switches ,fan regulator etc.
56One 3 pin /5 pin socket outlet 5 Amp controlled by 1 No one way 5/6 Amp switch on independent board.
57One light point controlled by two 2-way switches
58Material and labour for point wring ,using approved colour coding (Phase-red,Neutral-black,Earth-green) complete for one socket outlet 15 Amp on independent board with FRLS PVC insulated and unshealthedstranded copper conductor cable 2.5 sqmm single coreconforming to IS 694 including medium duty concealed unplasticised PVC conduit conforming to IS 9537(part-3) and ISI marked not less than 20 mm dia with concealed in wall pressed steel terminal box of not less than 2 mm thick of required size including painting terminal boxs inside and outside with two coat of synthetic enamle paint over one coat of red oxide primerwith top cover3 mm thickbakelight laminated sheetwith brass screws and Cup washer with all assessories including FRLS PVC insulated and unshealthedstranded copper conductor cable 2.5 sqmm single core in green colouras earth wireconnected to earth dolly complete all as specified and directed .
59S&F switch piano flush button single pole two way 6 Amp, 240 Volts conforming to IS 3854 ISI marked complete all as specified and directed.
60S&F switch piano flush button single pole one way 6 Amp, 240 Volts conforming to IS 3854 ISI marked complete all as specified and directed.
61S&Ffor socket outlet, 5 Pin, 6 Amp flush type conforming to IS 1293 ISI marked including complete all as specified and directed.
62S&F switch piano flush button single pole one way 15 Amp, 240 Volts conforming to IS 3854 ISI marked complete all as specified and directed.
63S&Ffor socket outlet, 3 Pin, 15 Amp flush type conforming to IS 1293 ISI marked complete all as specified and directed.
64S & Fceiling rose, surface Bakelite,isolated bodythree terminals complete all as specified and directed.
65S&F Electronic fan regulator steped type(flush type) 240 volt ,50Hz,single phase on existing phenotic laminated sheetand connecting complete all as specified and directed.
66S&F in repair switch piano flush button single pole two way 6 Amp, 240 Volts conforming to IS 3854 ISI marked complete all as specified and directed.
67S&F in repair switch piano flush button single pole one way 6 Amp, 240 Volts conforming to IS 3854 ISI marked complete all as specified and directed.
68S&F in repair for socket outlet, 5 Pin, 6 Amp flush type conforming to IS 1293 ISI marked including complete all as specified and directed.
69S&F in repairswitch piano flush button single pole one way 15 Amp, 240 Volts conforming to IS 3854 ISI marked including taking down old one complete all as specified and directed.
70S&F in repair for socket outlet, 3 Pin, 15 Amp flush type conforming to IS 1293 ISI marked including taking down old one complete all as specified and directed.
71S & Fin repairceiling rose, surface Bakelite,isolated bodythree terminals including taking down old one complete all as specified and directed.
72S&F in repair electronic fan regulator steped type(flush type) 240 volt ,50Hz,single phase on existing phenotic laminated sheetincluding taking down old one and connecting complete all as specified and directed.
73S&F sheet metal enclosures (MCB Distribution board) when MCB’s to be used singlepole and neutral 8 ways 220 volt with 200 amps rated bus bar, double door with bus bar neutral link earth bar, Din rail, necessary blanking plated, including fixing DB flush in wall complete with making good disturbed surfaces as per existing specified and directedincluding taking down old one complete all as specified and directed.
74S&F MCB’s single pole, 10 KA, 6 Amp to 30 Amp 240 Volts,and of ""B"" series with required wiring connections and lugs etcincluding taking down old one complete all as specified and directed.
75S&F MCB’s single pole and neutal, 32 Amp to 40 Amp 240 Volts,and of ""B"" series with required wiring connections and lugs etcincluding taking down old one complete all as specified and directed.
76Material and Labour for earthing complete with GI earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not lesss than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same.GI plate connected with GI wire 4.00mm by means ofnuts, bolts and washers.GI Wire shall be laid in 25mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) wih following complete all as specified and directed shown in electrical plate No. 3 of SSR Part-I & testing on completion :- (a)GI wire 4.00mm dia. (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit.(GI Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits) (c) PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothlyfinished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 25mm thick re-inforced with 8mm dia TMT bars @75mm centre to centre both ways with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover.
77S&F decorative, wall mounting, champagne gold finish fixture with plastic body suitable and including9 W LED lamp B22 base complete including taking down the old holder complete all as specified and directed.
78S&F in repair LED bulb 9 W complete all as specified and directed.
79S&F in repair Lamp holder, PVC/Polycarbonate type with back plate suitable for batten complete all as specified and directed.
80S&F Decorative ultra slim round profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient, 20 watt, 50 Hz including taking down the old fitting complete all as specified and directed.
81S&F 20W LED tube with double side connection, 6000K complete all as specified and directed.