Tender For Repair / Maintenance Of Different Type Of Summer / Winter Appliance In Otm / Md Accn Under Ge Banar - M&L For Taking Out Window / Split Type Ac Of Capacity Up To 2 Ton Of Any Make Fromthe Sitefor Servicing, Cleaning With Air Blower Of Fins, Cleaning Of Condensing Unit, Cooling Coil And Evaporative Coilwith Caustic Soda Mix Water, Taking Out All Dirt / Sludge Etc. By Usingpressure Pump , Cleaning Of Air Filter Incl. Oiling And Greasing Of Condensing Fan Motor, Replacement Of Remote Cell / Battery Replacing Worn Out Rubber, Bushes / Rubber Packing Rectification Of Unusual Noise. Replacement Of Minor Parts Such As Nut / Bolts, Washers And Writing Of Ser No Sm / Mes With Synthetic Enamel Paint Complete And Reassembly Of Complete Ac Unit And Testing Complete For Smooth Functioning To Entire Satisfactionofengineer-In-Charge. 2 M&L For Topping Up Ofrefrigerant As Per The Existing Refrigerant Upto The Required Levelfor Window / Split Type Ac Of Capacity 1.5 / 2 Ton Complete All As Specified. 3 M&L For Complete Gas Charging As Per The Existing Refrigerant Up To The Required Level Including Replacement Of Nrv For Window / Split Type Ac Of Capacity 1.5 / 2 Toncomplete All As Specified. 4 M&L For Taking Out Defective Compressor Sealed Rotary / Reciprocating Unit Of Window Ac Of Cap 1.5 Tonincl.Cutting Of Copper Tubing Without Any Damage To Existing Other Parts And Material And Labour For Replacement Of Compressor / Sealed Unit Complete With Erection Of Compressor In Same Location With Suitable Base, Jointing Of Copper Refrigerant Pipe Line, Charging Of Gas To Required Level, Leakage Testing, Nrv Etc. Including Testing For Smooth Functioning. Note : ( I ) The Rate Quoted By The Contractor Shall Be Inclusive Of All Charges Like Transportation, Fittings, Etc. Complete With Necessary Guarantee Period Including Oiling And Environment Friendly Gas Charging , Testing Etc. Complete All As Specified. 5 All As Per Ser No 4 Above But Split Type Ac Of Cap 1.5 Ton Completeall As Specified. 6 All As Per Ser No 4 Above But Split Type Ac Of Cap 2 Ton Completeall As Specified. 7 M&L For Replacement Of Blower Bush Of Split Type Ac Havingcapacities Of 1.5 / 2 Toncomplete All As Per The Sample Existing At The Ground. 8 Supply And Fix In Repair Blower Fan Motor Of Suitable Size For Indoor Type Split Acof Cap 1.5 / 2 Toncomplete All As Specified. 9 Supply And Fix In Repair Condensor Fan Motor Suitable For Out Door Type Split Ac Of Capacity 1.5 / 2 Toncomplete All As Specified. 10 M&L In Replacement Blower Of Wnidow Type Ac Of Cap 1.5 / 2.00 Ton Suitable For Window Type Ac Of Cap 1.5 / 2.00 Toncomplete All As Specified. 11 S & F In Replacement Wiring Kit Complete Suitable For Split Type Ac 1.5 / 2 Ton Capacity Complete With Lugs, Thimbles And Selector Switchcomplete All As Specified. 12 S&F In Replacement Of Running Capacitor, 45 / 60 Mfd Suitable For 1.5 / 2 Ton Capacity Window / Split Type Ac Complete All As Specified. 13 S & Fcapacitor 6 / 10 Mfd Suitable For Split / Window Type Accomplete All As Specified. 14 M&L For Repairing Of Pcb Control Kit Of Window / Split Type Ac Of Capacity 1.5 / 2Ton Complete All As Specified. 15 M & L For Replacement Of Pcb Control Kit Suitable For Window / Splittype Ac Of Capacity 1.5 / 2 Ton Complete All As Specified. 16 Takingdown Indoor & Outdoor Unit Of 1.5 / 2Tr Split Ac And Refix On Existing / Another Location Complete All As Specified. 17 S&F In Replacement Ofthermostat ( Thermal Sensing Bulb ) Suitable For Split / Window Type Ac 1.5 / 2Ton Capacity Complete All As Specified. 18 S&F In Replacement Of Starting And Running Relay Suitable For Window / Split Type Ac 1.5 / 2 Ton Capacity Complete All As Specified. 19 S&F In Replacement Of Over Load Protectionsuitable For Window / Split Type Ac 1.5 / 2Ton Capacity Complete All As Specified. 20 S&F In Replacement Drain Out Pipe Of Split Type Ac Unit Complete All As Specified. 21 Supply And Fix In Replacement Of Condensing Coil Of Window Type Ac Of Capacity 1.5 Toncomplete All As Specified. 22 Supply And Fix In Replacement Evaporating Coil Of Window Type Ac Of Capacity 1.5 / 2 Toncomplete All As Specified. 23 Supply And Fix In Replacement Of Evaporating Coil Of Split Type Ac Of Capacity 1.5 / 2Toncomplete All As Specified. 24 Supply And Fix In Replacement Of Condensing Coil Unit Complete Of Out Door Unit Of Split Type Ac Of Capacity 1.5 / 2 Toncomplete All As Specified. 25 M & L For Replacement Of Chocked Copper Tube Of Size 1 / 4 Of Split Type Ac 1.5 / 2 Ton Capcomplete All As Specified. 26 M & L For Replacement Of Chocked Copper Tube Of Size 1 / 2 Of Split Type Acof 1.5 / 2 Toncapcomplete All As Specified. 27 M & L For Insulation Coating / Pvc Air Bubling Insulation Of Circular Dia To Copper Tube To Upkeep The Required Temperture And Over All Protection To Copper Tubing Of Size 1 / 4 Or 1 / 2Complete All As Specified. 28 M & L For Taking Out Water Cooler From Site Of Any Capacity And Makefor Servicing Incl. Cleaning Of Coolingtank And Condencing Coil With C Sine Chemical Mixed Water, Taking Out All Dirt , Sludge Deposited, Incl. Oiling / Greasing Of Condensing Fan Motorrectification Of Unusual Noise, Replacement Of Minor Parts Such As Nut / Bolt Washers Etcas Directed With Writing Of Serialno Sm / Mes No With Synthetic Enamel Paint And Re Installed The Water Cooler In Position Complete All As Specified. 29 M&L For Topping Up Environment Friendly Refrigerant As Per Existing Suitable For Water Cooler Up To The Required Level Of 40 / 80 Ltrcomplete All As Specified. 30 M & L For Spray Painting To Body Of Water Cooler Of Capacity 40 / 80 Liter With Two Coat Of Synthetic Enamel Paint Complete All As Specified. 31 M & L For Replacement For Sealed Compressor Unit Of Suitable Capacity For Water Cooler Of 40 / 80 Lit / Hr Cap , Reassembly And Testingcomplete All As Specified. 32 M & L For Finding Out Leakage Ofcondensor / Cooling Unit Of Water Cooler Of 40 / 80 Ltr Cap Including Dismantling The Same For Recharging And Stop Leakage By Brazing / Soldering Including Charging With Existing Gas Up To Required Level And Testingcomplete All As Specified. 33 Material And Labour Forreplacement Of Capacitor 10 Mfd Oil Filled For Water Coolercomplete All As Specified. 34 Supply And Fixing Olp Rellay Suitable For Water Cooler, Refrigerator And Deep Freezer Of Any Capacitycomplete All As Specified. 35 M&L For Repair To Geysers Inner Water Tank Of 100 To 200 Ltrs. Capacity By Gas Welding / Brazing For Completely Arresting Leakage Including Testingcomplete All As Specified. 36 M & L For Replacement Of Condenser Fan Motor Of Water Cooler 40 / 80 Ltr / Hr Capacity Including Testing Complete All As Specified. 37 M & L For Replacement Of Fan Blade Of Water Cooler / Blower Complete All As Specified. 38 S & F In Repairs Ofthermostat Suitable For Water Cooler 40 Ltr / Hr Capacity Complete All As Specified. 39 Supply And Fix In Repair Ball Brass Valves Size 15Mm, High Pressure, With Polythene Float And Flynut Complete, Screwed For Iron Pipe Or Brass Ferrule Complete All As Specified. 40 M&L For Replacement Of Sealed Compressor Unit Upto 320 Ltr Cap Refrigerator.The Rates Quoted By The Contractor Shall Be Inclusive Of All Charges Like Transportation Fitting Etc Complete With Necessary Guarantee Periodincluding Checking And Rectification Of Any Leakage In System And Make It Functional To Entire Satisfaction Of Eic Incl Oiling, Greasing, Gas Charging And Testingcomplete All As Specified. 41 M&L For Finding Out Leakage With The Pressure Testing Of The Condensor / Cooling Unit / Compressor Of Refrigerator Upto 320 Ltr Cap, Stop Leakage By Brizing / Soldering Including Charging The Environment Friendly Refrigerant Up To The Required Level And Testing The Refrigerator For The Entire Satisfaction Of Eic. 42 M&L For Replacement Of Sealed Compressor Unit Of 320 Ltr Cap Deep Freezer.The Rates Quoted By The Contractor Shall Be Inclusive Of All Charges Like Transportation Fitting Etc Complete With Necessary Guarantee Periodincluding Checking And Rectification Of Any Leakage In System And Make In Functional To Entire Satisfaction Of Eic Incl Oiling, Greasing, Gas Charging And Testingcomplete All As Specified. 43 M&L For Finding Out Leakage With The Pressure Testing Of The Condensor / Cooling Unit / Compressor Of Deep Freezer 320 Ltr Cap, Stop Leakage By Brizing / Soldering Including Charging Withexisting Refrigerant To Required Level And Testing The Refrigerator For The Entire Satisfaction Of Eic. 44 S & F Replacement Of Swing Motor Suitable For 1.5 / 2 Ton Window And Split Type Ac All As Specified. 45 Supply And Fix In Repair Front Grillfor Window Type Ac 1.5 / 2.0 Tr. Complete All As Specified. 46 S&F In Replacement Of Remotesuitable For 1.5 / 2.0 Tr Split Type Ac Complete All As Specified. 47 Dismantlingto Voltage Stablizer Upto 4 Kvafor Repairincluding Assembling , Testing After Repair Work To Make It Functional Complete All As Specified. 48 S&F In Replacement Of Indoor Unit Complete With Cooling Coil, Blower / Fan, Motor Suitable For 1.5 Ton Split Accomplete All As Specified. 49 S&Fin Replacement Of Outer Cover Of Outdoor Cabinetof Split Ac 1.5Ton With Stand Including Fashner, Nut, Bolts Etccomplete All As Specified. 50 S&F In Repair 3 Core Pvc Insulated Copper Cable Of Size 2.5 Sqmm Multi Stranded Complete All As Specified. 51 Material And Labour For Painting To Old Steel Surfaces Of Desert Cooler Of Air Flow Capacityup To 5000 Cum / Hr With Two Coatsof Synthetic Enamel Spray Paint Hammer Tone Paint, Over One Coat Of Red Oxide On External Surface And Two Coats Of Anti Corrosive Black Paint Inside The Body Tank And Side Grills Over A Coat Of Red Oxide On Internal Surfaces Including Scraping / Rubbing With Wire Brush On Old Surface And Writing Of Mes No In 25Mm Height Etc Complete All As Specified. 52 M&L For Replacement Of Copper Conductor Cable 40 / 0.75 Sqmm 3 Core Of 5 M Length Including Plug Top 5 Ampinbuilt Suitable For Desert Coolercomplete All As Specified. 53 M&L For Replacement Of Pvc Water Distributor Including Pvc Pipe And Elbow Complete For Desert Cooler Upto 5000 Cfmcomplete All As Specified. 54 M&L For Replacement Of Fan Blade Of Desert Cooler Heavy Duty Hdpe Suitable For 4000 / 5000 Cft Capcomplete All As Specified. 55 M&L For Replacement Of Water Lifting Submersible Pump Of Head 1.2 M Approx Suitable For Desert Cooler Complete All As Specified. 56 M&L For Taking Downdesert Cooler Fan Motor And Supply And Fixing Newdesert Cooler Fan Motor ( Copper Wounded ) Three Speed With Outer Ring And Nut-Bolts For Desert Cooler Upto 5000 Cfm Complete All As Specified. 57 M&L For Taking Down U / S Desert Cooler Motor, Cutting Of Burnt Out Winding And Rewinding Super Enamelled Copper Conductorfixing Of Desert Cooler Motor To Existing Location Complete All As Specified And Directed By Engr-In-Charge. Make All As Directed By Eic. 58 Supply & Fix In Repairs Wood Wool Pad ( Set Of Three ) , Minimum Weight 0.80 Kg, Inside Panels Of Desert Coolerscomplete All As Specified. 59 Supply And Fix In Replaecment Of Selector Switchthree Speed With Knob Suitable For Desert Cooler Fan Motorcomplete All As Specified. 60 M&L For Collection Of Fans From E&M Yard, Removing To Workshop For Servicing, Cleaning, Lubricating, Spray Painting One Coat With Synthetic Enamel Paint, Writing Mes No. Replacement Of Split Pin, Rubber Bush And Other Spare Required If Any Including Fixing Pvc Cable With Stranded Copper Conductor Of Size 0.75 Sqmm Complete For The Following Sizes. ( Note:- Spares Like Bearing, Terminal Connector, Gun Metal Bushshall Be Measured And Paid Seperately As Supply Only ) 61 Ceiling Fans Of 1200 / 1400 Mm Size 62 Supply & Fix The Following Spare Parts :- 63 Bearing 6200 To 6203 Zz Make - Skf Or Equivalent 64 Terminal Connector 3 Way Bakelite 65 S & F In Replacementcapacitor 2.5Mfd 230 Voltscomplete All As Specified. 66 S & Fin Replacement Capacitor 4Mfd 230 Voltscomplete All As Specified. 67 Supply Andfix In Replacement Canopy For Ceiling Fans ( Set Of Two ) Complete All As Specified. 68 Supply Andfix In Replacement Ms Clamp With Rubber Reel, Nuts, Bolts, Split Pin Etc Suitable For 1200 / 1400 Mm Swwep Ceiling Fancomplete All As Specified. 69 M& L For Taking Down Of Fans From The Site, Transporting The Fans To Local Workshop, Rewinding Complete With Super Enamelled Copper Wire Of Same Guage And Weight, Replacement Of Insulation Paper, Varnishing, Capcitor Clip, Heating Up And Testing Complete Including Hanging / Fixing At Same Positions Complete For The Followings:- 70 Ceiling Fan 1200 / 1400Mm Sweep Working On 230 Volts Ac Supply 71 Exhaust Fan Upto 350Mm Sweep Working On 230 Volts Ac Supply 72 Exhaust Fan380 / 450Mmsweep Working On 230 Volts Ac Supply 73 Wall Mounting Fan Of 400 / 650 Mm Size, Working On 230 Volts Ac Supply 74 S&F In Replacement Down Rod Made Out Of Gi Pipe Medium Grade 15Mm Dia With Fan Clamps Incl Drilling, Cutting, Threading Etc All As Directed For Ceiling Fan 1200 / 1400 Sweep Of Following Sizes:- 75 4 Ft Long 76 6 Ft Long 77 Supply And Fix In Replacement Plug Top 15 Amps, 230 V All As Specified. 78 M&L For Replacement Of Ms Fan Blades Assembling For 300 / 380 / 450 Mmsweep Exhaust Fan Complete. 79 S&Fin Replacement Push Type Bib Tap Made Of Brass Chromium Plated For Water Cooler Upto 120 Ltr Capacity Complete All As Specified. 80 S&F In Replacement Water Tray Suitable Upto 120 Ltr Capacity Water Cooler Made Of Ss And All As Per Sample. 81 M&L For Taking Down Of Electric Water Heater ( Geyser ) From Wall Of Capacity 25 / 50Ltrs, Dismantling / Opening The Same, Servicing, Cleaning And Replacement Of Wornout, Ms Nut Bolts, Washers, Clamps, Suitable Fashner For Hanging Etc And Made Functional Fully Assembling, Connected And Testingcomplete All As Specified. 82 Supply & Fix In Replacement Thermostat Required At Site Suitable For The Geysers 25 Ltrs. To 50 Ltrs Capacitycomplete All As Specified. 83 Supply & Fix In Replacement Fusible Plug Suitable For 25 And 50 Ltrs. Capacity Geysers Complete All As Specified. 84 Supply & Fix In Replacement Safety Valve Suitable For25 And 50 Ltrs. Capacity Geysers Complete All As Specified. 85 Supply & Fix In Replacement Heating Element For 1.5 / 2Kw Rating As Required At Site ( Any Type ) Including Rubber Washers Complete All As Specified. 86 Supply & Fix In Replacement Storage Inner Tank Made Out Of Stainless Steel Sheet 2Mm Thick Suitable For Following Capacity Geysers Complete All As Specified. 87 25 Ltrs. 88 50 Ltrs. 89 Supply & Fix In Replacement Apparatus End Plate Including Rubber Washers For Geyser Of 25 To 50 Ltrs. Capacity Complete All As Specified. 90 Material And Labour In Replacement For Pvc Connection 15Mm Dia Of 450 Length Withbrass Nuts For Cold Side Suitable For Geyser Complete All As Specified. 91 Material And Labour In Replacement For Pvc Connection 15Mm Dia Of 600 Length Withbrass Nuts For Hot Side Suitable For Geyser Complete All As Specified. 92 Supply & Fix In Replacement Non-Return Valve 15Mm / 20Mm Dia Of Brass Complete All As Specified. 93 M&L For Repair To Geysers Inner Water Tank Of 25 To 50 Ltrs. Capacity By Gas Welding / Brazing For Completely Arrestingleakage Including Testing Complete All As Specified. 94 Supply & Fix In Replacement Indicators Set Of Geysers 25 To 50 Ltrs. Capacity ( Red / Green / Yellow ) Complete All As Specified. 95 Supply & Fix In Replacement Gasket Rubber Ring For Heater Plate Of Any Size Geysers Complete All As Specified. 96 De-Scaling Of Solar Water Heating System Complete Up To 300 Lpd Capacity Including Replacement Of Unserviceable Nut, Bolts, Washers, Change Fluid Inside Tube ( Propyleneglycol ) , Servicing Of The Flat Plate Collectorpanels By Chemical Washing Andminor Repair To Make The Solar System Functional Complete All As Specified. 97 Supply & Fix In Replacement Storage Inner Tank Made Out Of Steel Sheet Suitable For Following Capacity Solar Water Heater Complete All As Specified. 98 100 Ltrs. 99 200 Ltrs.