}

Tender For Extension Of Jigyasa Project At Ampri,Bhopal, bhopal-Madhya Pradesh

Council Of Scientific And Industrial Research-CSIR has published Tender For Extension Of Jigyasa Project At Ampri,Bhopal. Submission Date for this Tender is 24-01-2023. Earth Moving Machinery Tenders in bhopal Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

35783899
Corrigendum : Tender For Extension Of Jigyasa Project At Ampri,Bhopal
Open Tender
Indian
Madhya Pradesh
bhopal
24-01-2023

Tender Details

Tender For Extension Of Jigyasa Project At Ampri, Bhopal -1 Earth Work In Surface Excavation Not Exceeding 30 Cm In Depth Butexceeding 1.5 M In Width As Well As 10 Sqm On Plan Including Gettingout And Disposal Of Excavated Earth Upto 50 M And Lift Upto 1.5 M, Asdirected By Engineer-In- Charge: 1.01 All Kinds Of Soil 2 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means Over Areas ( Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sqm On Plan ) Including Getting Out And Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5 M, As Directed By Engineer-In-Charge. All Kinds Of Soil. 3 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level :1:4:8 ( 1 Cement : 4 Coarse Sand ( Zone-Iii ) : 8 Graded Stone Aggregate 40 Mm Nominal Size ) 4 Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level :1:1.5:3 ( 1 Cement : 1.5 Coarse Sand ( Zone-Iii ) Incuding Manufactured Sand Derived From Recycled Concrete Aggregate ( Rca ) Upto 20% : 3 Graded Stone Aggregate 20 Mm Nominal Size Of Recycled Concrete Aggregate ( Rca ) Upto 20%. 5 Reinforced Cement Concrete Work In Walls ( Any Thickness ) , Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. Above Plinth Level Up To Floor Five Level, Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement :1:1.5:3 ( 1 Cement : 1.5 Coarse Sand Incuding Manufactured Sand Derived From Recycled Concrete Aggregate ( Rca ) Upto 20% : 3 Graded Stone Aggregate 20 Mm Nominal Size Recycled Concrete Aggregate ( Rca ) Upto 20% 6 Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Staircases Above Plinth Level Up To Floor Five Level Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, With 1:1.5:3 ( 1 Cement : 1.5 Coarse Sand Incuding Manufactured Sand Derived From Recycled Concrete Aggregate ( Rca ) Upto 20%: 3 Graded Stone Aggregate 20 Mm Nominal Size Recycled Concrete Aggregate ( Rca ) Upto 20% ) 7 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form Work For :Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete 8 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form Work For Walls ( Any Thickness ) Including Attached Pilasters, Butteresses, Plinth And String Courses Etc. 9 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For Suspended Floors, Roofs, Landings, Balconies And Access Platform 10 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For : Lintels, Beams, Plinth Beams, Girders, Bressumers And Cantilevers 11 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For :Columns, Pillars, Piers, Abutments, Posts And Struts 12 Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level. Thermo-Mechanically Treated Bars Of Grade Fe-500 D Or More. 13 Providing And Fixing On Wall Face Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion, ( I ) Single Socketed Pipes 110 Mm Diameter 14 Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion. ----12.42.1 Coupler-----12.42.1.2 110 Mm 15 Providing And Fixing On Wall Face Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion. Single Tee With Door 110X110x110 Mm 16 12 Mm Cement Plaster Of Mix :1:4 ( 1 Cement: 4 Sand ) 17 18 Mm Cement Plaster In Two Coats Under Layer 12 Mm Thick Cement Plaster 1:5 ( 1 Cement : 5 Coarse Sand ) Finished With A Top Layer 6 Mm Thick Cement Plaster 1:6 ( 1 Cement : 6 Fine Sand ) . 18 Applying Priming Coat:With Ready Mixed Red Oxide Zinc Chromate Primer Of Approved Brand And Manufacture On Steel Galvanised Iron / Steel Works 19 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade : 20 Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. 21 Wall Painting With Premium Acrylic Emulsion Paint Of Interior Grade ( Plastic Paint ) , Having Voc ( Volatile Organic Compound ) Content Less Than 50 Grams / Litre Of Approved Brand And Manufacture, Including Applying Additional Coats Wherever Required To Achieve Even Shade And Colour.And Colour. Two Or Coats. 22 Applying Priming Coats With Primer Of Approved Brand And Manufacture, Having Low Voc ( Volatile Organic Compound ) Content. With Water Thinnable Cement Primer On Wall Surface Having Voc Content Less Than 50 Grams / Litre. 23 Structural Steel Work In Providing And Fixing Ms Grill In Windows In Position And Applying A Priming Coat Of Approved Steel Primer And Two Coat Of Oil Paint All Complete As Direction Of E-In-C 24 Supplying And Filling Moorum / Kopra, Base Of Floor / Rooad Etc. In Layers Not Exceeding 20Cm In Depth, Consolidating Each Deposited Layer By Vibratory Roller And Watering, Levelling Etc Complete 25 Brick Work With Chimny Brick Of Ravi / Kavi / Shree / A D In Superstructure Above Plinth Level Upto Floor V Level In All Shapes And Sizes In : Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) 26 Providing And Applying Multicoat Synthetic Plaster As Per Approved Design, Pattern Texture In 2 Mm Thick On New Plastered Surface Finished In Proper Line And Level As Directed By Engineer-In-Charge In Five Coats Consisting Of Composition Of Four Order Of Application Given As Under Includig All Materials, Labour And Scaffoldings Etc. 1 ) Scrapping Of The New Surface And Applying Sealer Primer Mixed With Water In The Ratio 1:3 ( Part Sealer Primer : 3 Part Water ) And Applying By Brush @ 0.25 Kg / Sqm. 2 ) Applying Levelling Coat Of Spectrum Rustic Fine Or Equivalent With Trwel As A Putty Finished To Generate Required Texture By Trowel. 3 ) Applying Third Coat Of Synthetic Plaster With Trwel @ 2.5 Kg / Sqm Finished To Generate Required Texture By Trwel. 4 ) Applying Two Coats Of Exterior Super Fine Pigmented Acrylic Wall Coating As Top Coat @ 0.5 Kg / Sqm In Two Coats And Colours As Approved By Engineer-In-Charge All Up To A Height Of 10M. 27 Providing And Laying Vitrified Tiles In Floor And Skirting Different Sizes ( Thickness To Be Specified By The Manufacturer ) With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Make, In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) Jointing With Grey Cement Slurry @ 3.3Kg / Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. Size Of Tile 600X600 Mm 28 Grouting The Joints Of Flooring Tiles Having Joints Of 3 Mm Width, Using Epoxy Grout Mix Of 0.70 Kg Of Organic Coated Filler Of Desired Shade ( 0.10 Kg Of Hardener And 0.20 Kg Of Resin Per Kg ) , Including Filling / Grouting And Finishing Complete As Per Direction Of Engineer-In-Charge.Size Of Tile 600X600 29 Providing And Fixing Flush Doors 30 Mm Thick Isi Mark With Decorative Lamination 0.75 Mm Thick On Both Sides Including Teak Wood Beading On Edeges Including L-Drop Ss Fiitings 10 & Tower Bolts 6 , Isi Marked Heavy Door Closer Etc Complete As Per E-In-C 30 Labour For Shifting Of Machines, Jungle Clearance, Junk Clearance, Septic Tank & Reconnection Of Tank Etc 31 P / F Glazed Aluminium Powder Coated Section In Windows And Ventilators Including All Fittings And Fixtures As Per E-In-C 32 Providing And Fixing Roller Blind Of Approved Make Design In Window Of Required Size In Approved Pattern And Design As Directed By E-In-C 33 Providing And Fixing Granite In Window Sill And Counter Platform And Steps / Ramp In Cm 1:4 Including Nosing, Grinding, Polishing Etc Complete As Per Site Requirement And Direction Of E-In C 34 P / F Ss Railing In 2 Dia Pipe Ht = 30 Including All Fittings And Fixtures As Per E-In-C 35 P / F 60 Mm Thick M-30 Grade Rubber Moulded Paver Block Laid On 50 Mm Thick Stone Dust With Filling Gaps With Sand And Locking Edeges With Concrete Completes As Per E-In-C 36 Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box / Celling Rose And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required.Group C. 37 Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Size Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Pvc Conduit As Required 37.01 2 X 1.5 Sq.Mm + 1 X 1.5 Sq.Mm Earth Wire. 37.02 2 X 2.5 Sq.Mm + 1 X 2.5 Sq.Mm Earth Wire. 37.03 2 X 4 Sq.Mm + 1 X 4 Sq.Mm Earth Wire. 37.04 2 X 6 Sq.Mm + 1 X 6 Sq.Mm Earth Wire.. 38 Supplying And Drawing Following 2 Pair 0.5 Mm Dia Frls Pvc Insulated Annealed Copper Conductor Telephone Cable In The Existing Surface / Rrecess / Steel / Pvc Conduit As Required 39 Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. 39.01 20Mm 39.02 25Mm 40 Supplying And Fixing Follwing Modular Switch / Socket On The Exixting Modular Plate & Switch Box Including Connections Excluding Moddular Plate Etc As Required. 40.01 5 / 6Amps Switch 40.02 3 Pin 5 / 6 Amps Socket Outlet 40.03 15 / 16 A Switch 40.04 6 Pin 15 / 16 A Socket Outlet 40.05 Telephone Socket Outlet 41 Supplying And Fixing Two Module Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including, Connections But Excluding Modular Plate Etc. As Required. 42 Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate & Switch Box Excluding Modular Plate As Required. 43 Supplyiong And Fixing Following Size / Modular Plate, Gi Box Alongwith Modular Base & Cover Plate For Modular Switchesin Recess Ets As Required 43.01 1 / 2 Module 43.02 6 Module 43.03 8 Module 44 Installation, Testing And Commissioning Of Ceiling Fan, Including Wiring The Down Rods Of Standard Length ( Upto 30 Cm ) With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor, Single Core Cable, Including Providing And Fixing Phenolic Laminated Sheet Cover On The Fan Box Etc. As Required. 45 Supplying And Drawing Of Utp 4 Pair Cat 6 Cable In The Executing Surface Recssed / Steel / Pvc Conduit, As Required 45.01 2 Run Of Cable 46 Supplying & Fixing Suitable Size Gi Box Wih Modular Plate And Cover In Front On Surface Or In Recess Including Providing And Fixing 25 A Modular Socket Outlet And 25 A Modular Sp Mcb, C Curve Including Connections, Painting Etc. As Required. 47 Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 V, On Surface / Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) 47.01 12 Way Double Door 48 Supplying And Fixing 5 Amps To 32 Amps Rating, 240 Volts C Series, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 48.01 Single Pole 48.02 Single Pole And Neutral 49 Supplying, Installation, Testing And Commissioning Of Prewired Led Compact Light Fitting Of Following Type Complete With All Accessories Etc. Recess / Surface / Panel / Flase Ceiling I / C Connection With 3 X 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Wire Earthing Etc. As Reqd. 49.01 Supplying And Fixing Of Led Surface Mounted Downlight 15 / 18 Watt With Lamp Complete With Connection And Testing Etc As Required As Per Havells Modal No.Glowgenxdls18wled857s Or Similar Make Like ( Havells / Crompton / Philips / Wipro ) 50 Supply, Installation, Testing And Commissioning Of 1200 Mm Sweep, Bee 5 Star Rated, Ceiling Fan With Brush Less Direct Current ( Bldc ) Motor, Class Of Insulation: B, 3 Nos. Blades, 30 Cm Long Down Rod, 2 Nos. Canopies, Shackle Kit, Safety Rope, Copper Winding, Power Factornot Less Than 0.9, Service Value ( Cm / M / W ) Minimum 6.00, Air Deliveryminimum 210 Cum / Min , 350 Rpm ( Tolerance As Per Is : 374-2019 ) , Thd Less Than 10%, Remote Or Electronic Regulator Unit For Speedcontrol And All Remaining Accessories Including Safety Pin, Nut Bolts, Washers, Temperature Rise=75 Degree C ( Max. ) , Insulation Resistance More Than 2 Mega Ohm, Suitable For 230 V, 50 Hz, Single Phase Acsupply, Earthing Etc. Complete As Required. 51 Supplying And Fixing Of Rj-45 Computer Socket Outlet Modular Type With Gio Box And Modular Plate I / C Making Connection Etc. As Reqd. 52 Sitc Of Invertor Type Split Air Conditioing, Minimum 3 Star Rating , Rotary Type Campressure , 1.5 Ton Capacity , 100 % Copper , Input Voltage 230 Volt, Eco Friendly Gas Swith Outdoor Stand And Complete Installataion, With Fixing Of Celling With Anchor Fasner Bolts, Laying Of Copper Wire Etc As Required ( Carrier / Hithachi / Blue Star / Daikin )

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 19-Jan-2023 EMD and Tender Fees Fee 24-01-2023

Key Value

Document Fees
INR 22500 /-
EMD
Refer document
Tender Value
INR 11.23 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail