Tender For Survey, Supply, Transporation, Carriage, Erection, Testing And Commissioning For 1 Creation Of 100 Kva Ss Along Ht Lt At Kashirah 2 Creation Of 100 Kva Ss Along Ht Lt At Kashirah Under Ut Capex On Turnkey Basis
Tender Overview
Project Description
Survey, Supply, Transporation, Carriage, Erection, Testing And Commissioning For 1 Creation Of 100 Kva Ss Along Ht Lt At Kashirah 2 Creation Of 100 Kva Ss Along Ht Lt At Kashirah Under Ut Capex On Turnkey Basis Creation Of 2 No Of 100 Kva Sub Station Along With Ht/Lt Network
BOQ
| Sl. No. | Item Description |
| 1 | Survey, Supply, Transportation, Carriage, Erection,Testing and Commissioning for Erection of 11 KV line on 9 mtr. ST poles, 30mm² ACSR Weasel Conductor at Kashirah |
| 2 | 9 mtr. Long ST Pole (ST-410 SP-33) |
| 3 | GI V Cross -arm with top Bracket including clamps |
| 4 | GI Channel X-arm including clamps and Angle for braces |
| 5 | 30mm² ACSRconductor |
| 6 | 11 KV Polymer composite Pin Insulator 12 KV, 5 KN, lighting impulse 75 KV Positive and 80 KV Negative, Creepage distance 320mm. |
| 7 | 11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75KVPositive and 80 KV Negative, creepage distance 320mm with fitting. |
| 8 | Galvanized Nuts and Bolts |
| 9 | Danger Plates with Clamps |
| 10 | Anti climbing device with clamps |
| 11 | Earthing complete byGI Rod 20 mm, 2.5 mtr long through G.I. Strip 25X3 mm |
| 12 | Painting of 9 mtr ST poles with two coat of Aluminium Paint. |
| 13 | Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole |
| 14 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI standed wire complete |
| 15 | Survey, Supply, Transportation, Carriage, Erection,Testing and Commissioning for erection of LT line 1 phase 2 wire on 8 mtr. ST pole at Kaishrah |
| 16 | 8 mtr. Long poles (ST-410 SP15) |
| 17 | GI M Clamps for shackle insulator |
| 18 | 30mm² ACSR Conductor |
| 19 | Shackle insualtor |
| 20 | Galvanized Nuts and Bolts. |
| 21 | Danger Plates with Clamps |
| 22 | Anti climbing device with clamps |
| 23 | Earthing complete by GI Rod 20mm 2.5 mtr. Long through GI Strip |
| 24 | Painting of 8 mtr ST poles with two coat of Aluminium Paint. |
| 25 | Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole |
| 26 | Survey, Supply, Transportation, Carriage, Erection,Testing and Commissioning for installation of 100 KVA Sub station at Kaishrah |
| 27 | 11/0.433 KV, 3-phase Distribution Transformer 100 KVA with Bimetallic Terminal Connectors Energy Level-2 Aluminium Wound & with LV Cable box having detachable Aluminium Gland plate |
| 28 | Gapless surge Arestor, 9 kv, 10 KA , LA with polymer housing stn. Type |
| 29 | 11 KV GO AB Switch 3 phase, 3 pole, 200 Amp, vertical |
| 30 | 11 KV Horn gap fuse set 3 phase 200 A |
| 31 | 185mm² (1ckt) 1.1 KV Grade, PVC insulated stranded conductor FRLS Type |
| 32 | 9 mtr. Long pole (ST-410 SP33) |
| 33 | 11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75KVPositive and 80 KV Negative, creepage distance 320mm with fitting. |
| 34 | GI Channel /Angle/flat of sizes including clamps |
| 35 | Galvanized Nuts and Bolts. |
| 36 | Earthing of sub stn. Excavation of earth pit of dia 650mm & depth 3000mm installation of earthing pipe of 40mm Nominal bore & 4mm wall thickness & length 2.5 mtr. Long as per IS 1239. G.I Strip for neutral earthing of size 25mmx3mmfor connection of transforemr body, GO Set & lightening arrestor as per IS 2629/85, GI Nuts & bolts refilled with earth enhancement materials and earth chamber with RCC Slab cover |
| 37 | 11 KV Poloymer composite pin insualtor, 12 KV, 5KN Lightening impulse 75 KV Positve and 80 KV Negative, creepage distance 320mm |
| 38 | LT distribution box for 100 KVA DTR with MCCB for incomer and SFU\"s for outgoing circuits |
| 39 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI standed wire complete |
| 40 | PG Clmaps |
| 41 | Danger Plates with Clamps |
| 42 | GI Barbed wire for Anticlimbing |
| 43 | 3-phase 4 wire LT Prodigy meter with box |
| 44 | Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole |
| 45 | Painting of ST poles 9 mtr. of sub stn. Including cross arm, clamps with 1 coat of Red oxide |
| 46 | Painting of ST poles 9 mtr. of sub stn. Including cross arm, clamps with 2 coat of Aluminium paint |
| 47 | Supply of 11kV GO, Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type |
| 48 | Supply of Gapless surge arrestor 9KV, 10KA, LA with polymer housing station type |
| 49 | Supply of 11KV Earthing /Discharge Rod (as per relevant IS ) for earthing of line at site (Set of 3) |
| 50 | Supply of Safety gloves (Insulating Electric Hand Gloves)ISI marked33000/7500 V |
| 51 | Survey, Supply, Transportation, Carriage, Erection,Testing and Commissioning for Erection of 11 KV line on 9 mtr. ST poles, 30mm² ACSR Weasel Conductor at Kashirah |
| 52 | 9 mtr. Long ST Pole (ST-410 SP-33) |
| 53 | GI V Cross -arm with top Bracket including clamps |
| 54 | GI Channel X-arm including clamps and Angle for braces |
| 55 | 30mm² ACSRconductor |
| 56 | 11 KV Polymer composite Pin Insulator 12 KV, 5 KN, lighting impulse 75 KV Positive and 80 KV Negative, Creepage distance 320mm. |
| 57 | 11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75KVPositive and 80 KV Negative, creepage distance 320mm with fitting. |
| 58 | Galvanized Nuts and Bolts |
| 59 | Danger Plates with Clamps |
| 60 | Earthing complete byGI Rod 20 mm, 2.5 mtr long through G.I. Strip 25X3 mm |
| 61 | Painting of 9 mtr ST poles with two coat of Aluminium Paint. |
| 62 | Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole |
| 63 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI standed wire complete |
| 64 | Survey, Supply, Transportation, Carriage, Erection,Testing and Commissioning for erection of LT 1 phase 2 wire on 8 mtr. ST pole at Kaishrah |
| 65 | 8 mtr. Long poles (ST-410 SP15) |
| 66 | GI M Clamps for shackle insulator |
| 67 | 30mm² ACSR Conductor |
| 68 | Shackle insualtor |
| 69 | Galvanized Nuts and Bolts. |
| 70 | Danger Plates with Clamps |
| 71 | Anti climbing device with clamps |
| 72 | Earthing complete by GI Rod 20mm 2.5 mtr. Long through GI Strip |
| 73 | Painting of 8 mtr ST poles with two coat of Aluminium Paint. |
| 74 | Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole |
| 75 | Survey, Supply, Transportation, Carriage, Erection,Testing and Commissioning for installation of 100 KVA Sub station at Kaishrah |
| 76 | 11/0.433 KV, 3-phase Distribution Transformer 100 KVA with Bimetallic Terminal Connectors Energy Level-2 Aluminium Wound & with LV Cable box having detachable Aluminium Gland plate |
| 77 | Gapless surge Arestor, 9 kv, 10 KA , LA with polymer housing stn. Type |
| 78 | 11 KV GO AB Switch 3 phase, 3 pole, 200 Amp, vertical |
| 79 | 11 KV Horn gap fuse set 3 phase 200 A |
| 80 | 185mm² (1ckt) 1.1 KV Grade, PVC insulated stranded conductor FRLS Type |
| 81 | 9 mtr. Long pole (ST-410 SP33) |
| 82 | 11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75KVPositive and 80 KV Negative, creepage distance 320mm with fitting. |
| 83 | GI Channel /Angle/flat of sizes including clamps |
| 84 | Galvanized Nuts and Bolts. |
| 85 | Earthing of sub stn. Excavation of earth pit of dia 650mm & depth 3000mm installation of earthing pipe of 40mm Nominal bore & 4mm wall thickness & length 2.5 mtr. Long as per IS 1239. G.I Strip for neutral earthing of size 25mmx3mmfor connection of transforemr body, GO Set & lightening arrestor as per IS 2629/85, GI Nuts & bolts refilled with earth enhancement materials and earth chamber with RCC Slab cover |
| 86 | 11 KV Poloymer composite pin insualtor, 12 KV, 5KN Lightening impulse 75 KV Positve and 80 KV Negative, creepage distance 320mm with fitting |
| 87 | LT distribution box for 100 KVA DTR with MCCB for incomer and SFU\"s for outgoing circuits |
| 88 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI standed wire complete |
| 89 | PG Clmaps |
| 90 | Danger Plates with Clamps |
| 91 | GI Barbed wire for Anticlimbing |
| 92 | 3-phase 4 wire LT Prodigy meter with box |
| 93 | Cement bottoming 1:2:4 mix as per REC standard 0.5 cum per pole |
| 94 | Painting of ST poles 9 mtr. of sub stn. Including cross arm, clamps with 1 coat of Red oxide |
| 95 | Painting of ST poles 9 mtr. of sub stn. Including cross arm, clamps with 2 coat of Aluminium paint |
| 96 | Supply of 11kV GO, Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type |
| 97 | Supply ofGapless surge arrestor 9KV, 10KA, LA with polymer housing station type |
| 98 | Supply of11KV Earthing /Discharge Rod (as per relevant IS ) for earthing of line at site (Set of 3) |
| 99 | Supply ofElectrical Safety shoes as per ISI |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender