| 1 | Taking down or dismantling existing unserviceable ACSR conductor of any sizefrom LT over head line by disconnecting & opening the winding and keep in a safe custody forfurther disposal complete all as specified and directed. |
| 2 | Dismantling of old unserviceable MS ironbracket and other frame work all as specified and directed. |
| 3 | Taking down old unserviceable insulators any type and size from over head linecomplete all as specified and directed. |
| 4 | Dismantling of GI earth wire / guard cradle wire from LT over head line by disconnecting of wire & winding and keeping aside for further disposal complete all as specified and directed. |
| 5 | Excavation in trenches in any type of soil and not exc 1.5 m wide and n.exc 1.5 m in depth for laying of cable and fixing poles, stays etc and getting out complete all as specified and directed. |
| 6 | Returning, filling in including spreading leveling, watering and well ramming in layers not exceeding 25 cm thick with excavated soil complete all as specified and directed. |
| 7 | Removing excavated material (surplus soil) to a distance not exceeding 50 mtrs and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed. |
| 8 | M&L river washed and screeened dry fine sand filling in trenches below and above / around under ground cable for cable protection including punniing around cable complete all as specified and directed. |
| 9 | Supply and laying , un-reinforced precast concrete cable cover ,class LV,Type I,flat,size 250mmX150mmX40mm with breaking load capacity 200 KG, complete all as specified and directed. |
| 10 | Supply and fixingonly 1100 volts grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connection , one twin core cable flat or circular with solid conductor of size 10 Sqmm complete all as specified and directed. |
| 11 | Labour only for laying of cable XLPEinsulated PVC sheathed, galvanised steel strip or wired armored. Electric power cable (heavy duty) 1100 V grade with stranderd aluminium conducter of size 10 Sqmm 2 core including lugs complete all as specified and directed. |
| 12 | All as per item No.11 above but 10 Sqmm 4.0 core. |
| 13 | All as per item No.11 above but 16 Sqmm 2.0 core. |
| 14 | All as per item No.11 above but 16 Sqmm 4.0 core. |
| 15 | All as per item No.11 above but 25 Sqmm 3.5 core. |
| 16 | All as per item No.11 above but 25 Sqmm 4.0 core. |
| 17 | All as per item No.11 above but 35 Sqmm 3.5 core. |
| 18 | All as per item No.11 above but 50 Sqmm 3.5 core. |
| 19 | All as per item No.11 above but 70 Sqmm 3.5 core. |
| 20 | All as per item No.11 above but 95 Sqmm 3.5 core. |
| 21 | All as per item No.11 above but 120 Sqmm 3.5 core |
| 22 | All as per item No.11 above but 150 Sqmm 3.5 core |
| 23 | All as per item No.11 above but 185 Sqmm 3.5 core. |
| 24 | All as per item No.11 above but 240 Sqmm 3.5 core. |
| 25 | Dismantling of old unserviceable steel poleany type by breaking PCC and taken away from site complete all as specified and directed. |
| 26 | Supply, transportation, erecting & fixing in truely vertical position , steel tubular swaged poleover all height 9.0 Mtrs , type 410-SP-31 complete with cast iron base plate, pole cap, finial taper plug, bolts, nuts washers and screws including painting two coats of aluminum paint over one coat of red-oxide primer and3 Nos bands/straps 30cm wide with post office red paintfrom plinth block and numbering of pole with black paint 2.5 cm in height including one coat of tarring of pole on steel surface embedded in concrete complete all as specified and directed.(Note : Excavation/earth work, PCC in foundation/ plinth block and cable protection pipe shall be measured and paid for seperately under appropriate item of schedule \"A\") |
| 27 | All as per srl item No 5 above but exc 1.5 mtr in depth but n exc 3.00 mtr depth complete all as specified and directed. |
| 28 | M&L for PCC 1:3:6 type C-1 (using 20 mm graded stone aggrigate) as incoping above ground including necessary form work, complete all as specified and directed. |
| 29 | Material and labour forcement concrete 1:3:6 (40mm graded aggregate ) type C-2 for foundation of poles including necessary form work complete all as specified and directed. |
| 30 | S& F in replacement Automatic street light switch usingNature switch based on LUX level of nature light, three phase 8kw, contactor rating 25 Amps, MCB rating 32 Amps, complete all as specified and directed. |
| 31 | S&F in replacent of junction box made from SMC/FRP sheet ready made of size300 x 200 x 100 mmhaving 100Acapacity forRYB and neutral with aluminium buster with4 way connectorfixed to pole/wall with MS clamp25 x 5mmand nut bolts including following :-(a) MCB SP 6 Amp 10 KA 240 Volt with aluminium lugs -01 No complete all as specified and directed. |
| 32 | Supply and fixing in replacementofMCCB 125 Amps 4 Pole 25 KAcomplete all as specified and directed. |
| 33 | Supply and fixing in replacement of bus bar chamber factory made, outdoor type made out of 3.15mm CRCA sheet of size 700x450x300 pedestal type with 200Amps rated aluminium bus bar TPN system & space ofOne No MCCB 125 Amps 4 Pole complete all as specified and directed. |
| 34 | M&L for earthing complete with galvanised steel earth plate electrode 600x600x6.0 mm thick buried directly in ground and earth pit not less than 2.25 mtr deep below NGL and top edge of the plate not less than 1.5 Mtr deep below NGL, surrounded with adequate qty of char coal dust mixed with salt to a packed thickness not less than 15 Cm on all sides of earth plate incl excavation, earth work, returning filling in , removal of surplus soil to a distance in n.exc. 50 mtr incl GI strip 25x4mm dia nut bolts etc to earth plateone end connected to continuous earth wire incl GI pipe watering light grade with CI funnel and wire mesh and PCC 1:2:4 type B-1 as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1 duly re-enforced with MS bar 6mm dia @ 150mm C/C both ways with 10mm dia MS bar lifting handles, all as described in electric plate No. 3 of SSR part-I complete all as specified and directed. |
| 35 | Supply and laying in replacement GI tube light grade in trenches/wall for Cable Protection of followingsize including all required fittings complete all as specified & directed. |
| 36 | 50 mm dia |
| 37 | 40 mm dia |
| 38 | 80mm Dia |
| 39 | 100mm Dia |
| 40 | Material and labour for cutting the existing bituminuos road for passing of UG Cable in road crossing and making good the disturbed surface of road to its original specification complete all as specified and directed. |
| 41 | M & L for cutting, trimming and prunning of trees/tree branches of any girth upto 2.5 m all around existing LT over head lines / sourrounding street light and flood fitting including cleaning the area beneath the LT overhead lines and removing thedebris from the site and depositing where complete all as specified and directed. |
| 42 | Supply and fixing of ACSR aluminium conductor, steel reinforced of any size and type maintained standard sag including providing aluminium binding wire, aluminium jointing, jumper etc., complete all as specified and directed. |
| 43 | S&F cable jointing kit1.1 KV (Earthed) grade cable for straight through heat shrinkable type joint complete with jointing material and accessories suitable for3.5 core XLPEarmoured aluminium conductor cable of size 50 to 95 Sqmm, complete all as specified and directed. (Including finding out the fault.) (Note : Exc of earthwork will be measured and paid seperately.) |
| 44 | S&F cable jointing kit1.1 KV (Earthed) grade cable for straight through heat shrinkable type joint complete with jointing material and accessories suitable for3.5 core XLPEarmoured aluminium conductor cable of size 120 to 185 Sqmm, complete all as specified and directed.(Including finding out the fault.) (Note : Exc of earthwork will be measured and paid seperately.) |
| 45 | S&F cable jointing kit1.1 KV (Earthed) grade cable for straight through heat shrinkable type joint complete with jointing material and accessories suitable for3.5 core XLPEarmoured aluminium conductor cable of size 240 Sqmm, complete all as specified and directed. (Including finding out the fault.) (Note : Exc of earthwork will be measured and paid seperately.) |
| 46 | M&L for replacement of cross arms, bracings, supports, clamps and back plates fabricated from structural steelsections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed. |
| 47 | Supply and fixing Pin type procelain, Vitreous, White, brown or green insulator including one galvanised mild steel spindle two galvanised iron washer and one galvanised iron nut100 mm height , 65 mm dia for 1100 volt grade complete all as specified and directed. |
| 48 | Supply and fixing Galvanised steel earth wire 4 mm dia complete all as specified and directed. |
| 49 | Supply and fixing cable route indicator made of MS sheet of size 200 mm x 150 mm x 3 mm thickwelding withangle iron of size 40 x 40 x 5 mm thick, 750 mm long embedded in PCC (1:2:4) type B-2 (using 40 mm graded crushed stone aggregate) block of size 300 x 300 x 400mm including one coat of synthetic enamel black paint over a coat of zinc chrome red oxideprimer and writing letter with white paint showing size of cable, LT/HT complete all asspecified & directed. |
| 50 | NOTES :-1.For the items for which specifications not mentioned any where in the tender, the BIS specifications shall be followed. |