Tender For Repair/Maintenance Of Centrifugal / Submersible Pump Sets, Motors Starters And Cleaning Of Ug Sumps, Storage Sumps, Filters Of Water Supply Installation And Water Testing At Upper Leimakhong, Lower Leimakhong, Central Sector And Koirengi., leimakhong-Manipur

Military Engineer Services-MES has published Tender For Repair/Maintenance Of Centrifugal / Submersible Pump Sets, Motors Starters And Cleaning Of Ug Sumps, Storage Sumps, Filters Of Water Supply Installation And Water Testing At Upper Leimakhong, Lower Leimakhong, Central Sector And Koirengi.. Submission Date for this Tender is 13-02-2023. Starter Tenders in leimakhong Manipur. Bidders can get complete Tender details and download the document.




Tender Notice

35760424
Corrigendum : Tender For Repair/Maintenance Of Centrifugal / Submersible Pump Sets, Motors Starters And Cleaning Of Ug Sumps, Storage Sumps, Filters Of Water Supply Installation And Water Testing At Upper Leimakhong, Lower Leimakhong, Central Sector And Koirengi.
Open Tender
Indian
Manipur
leimakhong
13-02-2023

Tender Details

Repair / Maintenance Of Centrifugal / Submersible Pump Sets, Motors Starters And Cleaning Of Ug Sumps, Storage Sumps, Filters Of Water Supply Installation And Water Testing At Upper Leimakhong, Lower Leimakhong, Central Sector And Koirengi.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 06-Feb-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 13-02-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 30000.0 /-
Tender Value
INR 15 Lakhs /-

BOQ Items

Name of Work:REPAIR/MAINT OF CENTRIFUGAL / SUBMERSIBLE PUMP SETS, MOTORS STARTERS AND CLEANING OF UG SUMPS, STORAGE SUMPS, FILTERS OF WATER SUPPLY INSTALLATION AND WATER TESTING AT UPPER LEIMAKHONG, LOWER LEIMAKHONG, CENTRAL SECTOR AND KOIRENGI.
Sl. No. Item Description
1Schedule "A"
2Taking out old filter media of different grades/sizes of pressure filters one by one in layer and laying out manually including segregating useful materials etc complete all as specified and directed
3Cleaning & washing of old serviceable filter media of different grades (taken out under item No 1.00 here-in-before) and repacking the retrieved/cleaned media in different layers complete all as specified and directed
4M&L for new filter media/ferrimanex and repacking in different layers, sand of 16/30 mesh complete all as specified and directed.
5M&L for cleaning of inner surfaces of RCC under ground sump / semi under ground sump including floor of water intake sump includingfloor of water intake sump and applying two coats of white wash after taking out and removing silt, sludge, moss, algae, dirt etc. complete all as specified and directed upto the entire satisfaction of Engineer-in-charge for the followingNote :- (i) The unit rate quoted shall bedeemed to include draining of water with mechanical equipment and working in water and mud etc. (ii) The unit rate quoted shall be deemed toinclude all safety precautions which shall be taken while working on RCC underground sump/semi under ground sump. (iii) Lighting arrangements if required to be provided by the contractor temporarily at his own arrangements and the amount quoted for that shall be deemed to be inclusive in the unit rate and electricity / diesel shall not be provided by the Department. (iv) Contractor will not be allowed more than one day to complete the work insideeach UG sump to prevent interruption of water supply to the users. (v)The date of cleaning and due date of cleaning must be painted with synthetic enamel paint on the out side of the front tank wall as specified and directed by Engr-in-Charge (a)Semi under ground sump of capacity 75000 Gallon at High Lift Pump House
6M&L for cleaning of inner surfaces of RCC under ground sump / semi under ground sump including floor of water intake sump includingfloor of water intake sump and applying two coats of white wash after taking out and removing silt, sludge, moss, algae, dirt etc. complete all as specified and directed upto the entire satisfaction of Engineer-in-charge for the followingNote :- (i) The unit rate quoted shall bedeemed to include draining of water with mechanical equipment and working in water and mud etc. (ii) The unit rate quoted shall be deemed toinclude all safety precautions which shall be taken while working on RCC underground sump/semi under ground sump. (iii) Lighting arrangements if required to be provided by the contractor temporarily at his own arrangements and the amount quoted for that shall be deemed to be inclusive in the unit rate and electricity / diesel shall not be provided by the Department. (iv) Contractor will not be allowed more than one day to complete the work insideeach UG sump to prevent interruption of water supply to the users. (v)The date of cleaning and due date of cleaning must be painted with synthetic enamel paint on the out side of the front tank wall as specified and directed by Engr-in-Charge (b) Semi under ground sump of capacity 50000 Gallon at High LiftPump House Nos-04,Low Lift Pump house Nos- 01,Near Capt QtrSump Nos -03, KLP Pump House Nos-01.
7M&L for cleaning of inner surfaces of RCC under ground sump / semi under ground sump including floor of water intake sump includingfloor of water intake sump and applying two coats of white wash after taking out and removing silt, sludge, moss, algae, dirt etc. complete all as specified and directed upto the entire satisfaction of Engineer-in-charge for the followingNote :- (i) The unit rate quoted shall bedeemed to include draining of water with mechanical equipment and working in water and mud etc. (ii) The unit rate quoted shall be deemed toinclude all safety precautions which shall be taken while working on RCC underground sump/semi under ground sump. (iii) Lighting arrangements if required to be provided by the contractor temporarily at his own arrangements and the amount quoted for that shall be deemed to be inclusive in the unit rate and electricity / diesel shall not be provided by the Department. (iv) Contractor will not be allowed more than one day to complete the work insideeach UG sump to prevent interruption of water supply to the users. (v)The date of cleaning and due date of cleaning must be painted with synthetic enamel paint on the out side of the front tank wall as specified and directed by Engr-in-Charge(c) Semi under ground sump of capacity 25000 Gallon at High Lift pump house-01, KLP pump house-01
8M&L for cleaning of inner surfaces of RCC under ground sump / semi under ground sump including floor of water intake sump includingfloor of water intake sump and applying two coats of white wash after taking out and removing silt, sludge, moss, algae, dirt etc. complete all as specified and directed upto the entire satisfaction of Engineer-in-charge for the followingNote :- (i) The unit rate quoted shall bedeemed to include draining of water with mechanical equipment and working in water and mud etc. (ii) The unit rate quoted shall be deemed toinclude all safety precautions which shall be taken while working on RCC underground sump/semi under ground sump. (iii) Lighting arrangements if required to be provided by the contractor temporarily at his own arrangements and the amount quoted for that shall be deemed to be inclusive in the unit rate and electricity / diesel shall not be provided by the Department. (iv) Contractor will not be allowed more than one day to complete the work insideeach UG sump to prevent interruption of water supply to the users. (v)The date of cleaning and due date of cleaning must be painted with synthetic enamel paint on the out side of the front tank wall as specified and directed by Engr-in-Charge(d) Semi under ground sump of capacity 6400 Gallon at High Lift Pump house.
9M&L for cleaning of inner surfaces of RCC under ground sump / semi under ground sump including floor of water intake sump includingfloor of water intake sump and applying two coats of white wash after taking out and removing silt, sludge, moss, algae, dirt etc. complete all as specified and directed upto the entire satisfaction of Engineer-in-charge for the followingNote :- (i) The unit rate quoted shall bedeemed to include draining of water with mechanical equipment and working in water and mud etc. (ii) The unit rate quoted shall be deemed toinclude all safety precautions which shall be taken while working on RCC underground sump/semi under ground sump. (iii) Lighting arrangements if required to be provided by the contractor temporarily at his own arrangements and the amount quoted for that shall be deemed to be inclusive in the unit rate and electricity / diesel shall not be provided by the Department. (iv) Contractor will not be allowed more than one day to complete the work insideeach UG sump to prevent interruption of water supply to the users. (v)The date of cleaning and due date of cleaning must be painted with synthetic enamel paint on the out side of the front tank wall as specified and directed by Engr-in-Charge(e) Semi under ground sump open type of capacity 10000 Gallon at Low Lift Pump house.
10Dismantling and strip opening of pumps completely including disconnecting the suction, delivery, vaccum pipe lines and coupling for repairs to pump and refitting/ re-assembling & connecting the same and testing of pumps complete all as specified and directed for the following capacities:- (a) Pump capacity 100 HP Note : (i) The rate considered is inclusive of T&P required for carrying out the repairs. (ii)The rate considered is inclusive of cost towards miscellaneous items such as cotton waste, grease and other consumables. (iii)The rate considered is inclusive of checking of alignment of pump with dial gauge after refitting. (iv)The cost of spares for pump considered separately under appropriate items here-in-after. (v) The rate considered are inclusive of transporting the pumps to Wksp and back to installation site.
11Dismantling and strip opening of pumps completely including disconnecting the suction, delivery, vaccum pipe lines and coupling for repairs to pump and refitting/ re-assembling & connecting the same and testing of pumps complete all as specified and directed for the following capacities:- (a) Pump capacity 20/15 HP Note : (i) The rate considered is inclusive of T&P required for carrying out the repairs. (ii)The rate considered is inclusive of cost towards miscellaneous items such as cotton waste, grease and other consumables. (iii)The rate considered is inclusive of checking of alignment of pump with dial gauge after refitting. (iv)The cost of spares for pump considered separately under appropriate items here-in-after. (v) The rate considered are inclusive of transporting the pumps to Wksp and back to installation site.
12Supply only the following spares for pump sets of capacity 100 HP (Note: Make of spares shall be of the original make of the pump) Make :- Kirloskar/ CG(11.01)Pump Shaft
13(11.02) Bronze impeller 1st stage
14(11.03) Bronze impeller 2nd stage
15(11.04) Wear ring Bronze
16(11.05) Inter stage ring Bronze
17(11.06) Water deflector rubber
18(11.07 ) Bearing cartridge cast iron drive end
19(11.08 ) Bearing cartridge cast iron non drive end
20(11.09) Shaft sleeve bronze drive end
21(11.10) Shaft sleeve bronze non drive end
22(11.11) Spacer sleeve drive end
23(11.12) Spacer sleeve non drive end
24(11.13) Key for impeller and sleeve
25(11.14) Bearing lock nut
26(11.15) Stuffing box bush
27(11.16) O" ring for shaft sleeve
28(11.17) Cast iron gland (Set of 2 halves)
29(11.18) Eye bolt for gland with nut and washer
30(11.19) Gland guide bush large
31(11.20) Gland guide bush small
32(11.21) Center link bush
33(11.22)Check nut
34(11.23) Shaft Pulley
35Supply only the following spares for pump sets of capacity 20HP / 15 HP (Note: Make of spares shall be of the original make of the pump)Make :- Kirloskar/ CG (34.01) Pump Shaft
36(34.02) Impeller
37(34.03) Casing wear ring
38(34.04) Casing cover
39(34.05) Lantern ring
40(34.06) Gland collar
41(34.07) Liquid deflector
42(34.08) Bearing housing
43(34.09) Support foot
44(34.10) Bearing cover
45(34.11) Shaft sleeve
46(34.12) Key for impeller
47(34.13) Key for coupling
48(34.14) Impeller nut
49(34.15) Washer for impeller
50(34.16) Gland packing
51(34.17) Grease Nipple
52(34.18) Gasket for casing cover
53(34.19) Gasket for shaft sleeve and shaft
54(34.20) O" ring for sleeves & impeller
55(34.21) Tie rod
56Supply only Ball bearing/Roller bearing/drive end bearing / non end bearing for the following pumpsets:Pump Capacity 100HP (Make: SKF/FAG/Rolon/NRB)
57Supply only Ball bearing/Roller bearing/drive end bearing / non end bearing for the following pumpsets:Pump Capacity 20/15HP (Make: SKF/FAG/Rolon/NRB)
58Dismantling and strip opening of motor completely including disconnecting the cable connections and coupling of the motor removing the starter and rotor units, bearings complete, servicing the motor assembly including cleaning the carbon, greasing the bearings etc.and refitting the same after repairs including connecting up of the electric connections & testing complete all as specified by Engr-in-charge for the following capacities:- Motor capacity 100HP Note : (i)The rate considered is inclusive of tools and plants required for carrying out the repairs. (ii)The rate considered is inclusive of cost towards miscellaneous items such as cotton waste, grease and other consumables. (iii)The rate considered is inclusive of checking of alignment of pump with dial gauge after refitting. (iv) The rate considered are inclusive of transporting the motors to Wksp and back.(v)The cost of spares for pump considered separately under appropriate items here-in-after.
59Dismantling and strip opening of motor completely including disconnecting the cable connections and coupling of the motor removing the starter and rotor units, bearings complete, servicing the motor assembly including cleaning the carbon, greasing the bearings etc.and refitting the same after repairs including connecting up of the electric connections & testing complete all as specified by Engr-in-charge for the following capacities:- Motor capacity 20/15HP Note : (i)The rate considered is inclusive of tools and plants required for carrying out the repairs. (ii)The rate considered is inclusive of cost towards miscellaneous items such as cotton waste, grease and other consumables. (iii)The rate considered is inclusive of checking of alignment of pump with dial gauge after refitting. (iv) The rate considered are inclusive of transporting the motors to Wksp and back.(v)The cost of spares for pump considered separately under appropriate items here-in-after.
60Material & Labour for rewinding of electric motor starter or rotor after removing the burnt out winding wire completely, cleaning the slots of starter or rotor thoroughly and rewinding with same gauge, number of turns, weight of super enamelledcopper winding wire complete including varnishing and heating all as specified anddirected of the following sizes:(a) Electric motor, 3 phase 100 HP capacity
61Material & Labour for rewinding of electric motor starter or rotor after removing the burnt out winding wire completely, cleaning the slots of starter or rotor thoroughly and rewinding with same gauge, number of turns, weight of super enamelledcopper winding wire complete including varnishing and heating all as specified anddirected of the following sizes:(a) Electric motor,20/15 HP capacity
62Supply only ball bearing/ roller bearing (Non drive end bearing) for the following electric motor.Electric motor, 3 phase 100 HP capacity (Make: SKF/FAG/Rolon/NRB)
63Supply only ball bearing/ roller bearing (Non drive end bearing) for the following electric motor.Electric motor,20/15 HP capacity (Make: SKF/FAG/Rolon/NRB)
64S&F rubber coupling high speed PHF 110 suitable for centrifugal pumpset complete all as specified and as directed
65Testing of water for potability test by chemical and bacteriological from any Govt. laboratory such as PH value, Total dissolved solids, hardness as CaCO?, Calcium, Magnesium, Chlorides, Sulphates, Nitrate, Alkalinity, Iron, Turbidity NTU, Mineral oil, Colur hazen units, Taste, Odour, Residual free Chlorine, Total Coliform per 100ml (Microbiologocal test) & E Coli per 100ml (Microbiological test) complete and report to be submitted to the department in triplicate in hard bound copy complete all as specified and as directed
66S&F in repair fully automatic star delta motor starter in sheet enclosure or fix type ML-03 suItable for 100 HP electric motor 3 phase, 440 volts and 50 HZ complete all as specified and directed. Make : BCH / Havells / L&T / Siemens / Crompton Greaves
67S&F in repair fully automatic star delta motor starter in sheet enclosure or fix type ML-03 suItable for 20/15 HP electric motor 3 phase, 440 volts and 50 HZ complete all as specified and directed. Make : BCH / Havells / L&T / Siemens / Crompton Greaves
68S&F in repairs cast iron flanged type foot valve 200mm dia bore as per IS 4038 with Cast Iron strainer in two parts, mushroom valve gun metal seat and perforated CI/MS strainercomplete all as specified and directed. (Make: Kirloskar (KBL)/L&T/Leader)
69S&F in repairs cast iron flanged type foot valve 150mm dia bore as per IS 4038 with Cast Iron strainer in two parts, mushroom valve gun metal seat and perforated CI/MS strainercomplete all as specified and directed. (Make: Kirloskar (KBL)/L&T/Leader)