| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group B |
| 2 | Providing and fixing G.I. pipe complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall |
| 3 | 50 mm |
| 4 | 40 mm |
| 5 | 25 mm |
| 6 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : |
| 7 | 50 mm |
| 8 | 40 mm |
| 9 | Providing and fixing non-return valve of following size for the existing pump etc. as required at site. (50 mm) |
| 10 | Providingand fixing G.I. union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete. |
| 11 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 185 sq. mm |
| 12 | Providing and fixing of 10 HP open well submerisble pump 3 phase 440 volts AC supply complete with all accessories etc as required at site. (Model Nos. OWS10 2G-33) (Crompton) (Dream Building) |
| 13 | Providing and fixing of water level sensor for the existing pump etc. as required at site. (KSB)` |
| 14 | Fully rewinding of 7.5 Hp open well submersible pump after cutting the existing winding with super enameled copper wire at the existing gauge i/c varnishing, heating etc. as required at site. (Central Office) |
| 15 | Supplying and fixing of mechanical seal for the 7.5 HP open well submersible pump etc. as required at site. |
| 16 | S/F 3x4 sq.mm PVC insulated PVC sheathed copper conductor flexible cable i/c connection etc. as required, |
| 17 | Providing and fixing of 3 HP motor of the hiring charging for the removing of water from the tank by the suitable arrangement etc. as required. |
| 18 | S/F testing & commissioning of panel board 3 phase 4 wire system 415V AC supply |
| 19 | Incoming 1 Nos. VM 0-500v1 Nos. AM meter Analog 0-20V with in built selector switch 0-20 amps Outgoing1 Nos. ML 1.5 Star delta starter, 1 nos. Overload relay 13 to 20 amps1 Nos. TPN 63 amps MCBIndication light and ON/OFF buttonComplete with all accessories as per required at site. |
| 20 | Supplying/ fixing/ laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size including excavation, sand cushioning, protective covering and refilling the same etc. as required. |
| 21 | 4 x 16 sq.mm |
| 22 | 3 x 6 sq.mm |
| 23 | Supplying and fixing following 63 amps , TPN MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 24 | Cleaning of tank after removing of left over dirty drain water from the existing tank with sludge removal pump etc. as required at site. |
| 25 | S/F/testing and commissioning ofLED single box type fitting (1x20Watts) complete with all accessories and tube etc. directly on ceiling or wall i/c connection with 1.5sqmm FR PVC copper cond. cable etc. as required.(TMC 501 P 1XT LED 20W P3241 ) (Philips) |
| 26 | Providing and fixing of 5 HP submersible pump 3 phase 440 volts AC supply complete with all accessories etc. as required at stie. (Model No. 4W10BJ5DM) (Crompton/Becon/Mody) (Central Office |
| 27 | S/F/I/T & commissioning of three phase starter suitable for 1 Nos. volts meter, 1 Nos. amps meter 230 volts AC supply i/c making connections etc. as required at site. |
| 28 | Finding and detecting location of underground LT cable with FLC machine including excavation, pin pointing , fault , refilling after repair of ground at marked fault as required at site. |
| 29 | Making provision of digging ouit the fault location upto 10 mtr for making straight through joint by tracing out the loop and then refilling the trench after restoration the electric supply etc. as required at site. |
| 30 | Making temporary arrangement of the cable (3 ½ x 50 sqmm) from joint to main cable for restoring the power supply and making connection etc. as required at site (approx. 65 mtr cable) |
| 31 | Supplying, fixing and laying of one number of PVC insulated and PVC sheathed/ XLPE aluminium armoured conductor power cable confirming to 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering, refilling the same etc. as required. 3 ½ x 185 sqmm |
| 32 | Making provision of cutting the road RCC by mechine/ machanical of suitable size for removing of 3 ½ x 185 sqmm aluminium armoured cable and repairing the same with cement concrete i/c disposal the malba etc. as required at site. |
| 33 | Supplying and fixing following 32 amps DP MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 34 | Providing and fixig of 1 Hp Monoblock pump single phase 230 volts AC supply i/c making connection etc. as required at site. |