Repair / Maintenance Of Flood Lights, High Mast Lights, Street Light Cables, Feeder Piller Boxes, Switch Gear And Connected Items Under Ge Hisar, hisar-Haryana

Military Engineer Services-MES has published Repair / Maintenance Of Flood Lights, High Mast Lights, Street Light Cables, Feeder Piller Boxes, Switch Gear And Connected Items Under Ge Hisar. Submission Date for this Tender is 17-02-2023. Couplers Tenders in hisar Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

35740833
Corrigendum : Repair / Maintenance Of Flood Lights, High Mast Lights, Street Light Cables, Feeder Piller Boxes, Switch Gear And Connected Items Under Ge Hisar
Open Tender
Indian
Haryana
hisar
17-02-2023

Tender Details

Repair / Maintenance Of Flood Lights, High Mast Lights, Street Light Cables, Feeder Piller Boxes, Switch Gear And Connected Items Under Ge Hisar- S&F in replacement high mast light fitting of any type with LED flood light fitting of cap 120 Watt, 240 Volts, energy saving, environmental friendly, long life, exclusive innovative, die cast aluminium IP66 flood light suitable for highlighting architectural facade and general purpose lighting complete with accessories, pre-wired upto a terminal block and mounting attachment complete all as specified and directed. 2 S&F in replacementLED flood light fitting of cap 100 Watt, 240 Volts, energy saving, environmental friendly, long life, exclusive innovative, die cast aluminium IP66 flood light suitable for highlighting architectural facade and general purpose lighting complete with accessories, pre-wired upto a terminal block and mounting attachment complete all as specified and directed. 3 S&F in replacementLED flood light fitting of cap 70Watt, 240 Volts, energy saving, environmental friendly, long life, exclusive innovative, die cast aluminium IP66 flood light suitable for highlighting architectural facade and general purpose lighting complete with accessories, pre-wired upto a terminal block and mounting attachment complete all as specified and directed. 4 Supply and fixing in repairs LED highbay light 100 W suspended or surface type with very high efficiency in PDC housing suitable for sheds. The luminaire has efficacy upto 150Lm/W with Ingress protection of IP66 including connecting 3 core copper wire complete all as specified and directed 5 S&F in replacement post top LED lantern of capacity 20 Watt complete, 230 V AC outdoor type with decorative post for 360 degree indirect light IP-65 protection with impact and corrosion resistant complete with driver and LED lamp all as specified & as directed. 6 S&F in replacement post top LED lantern of capacity 40 Watt complete, 230 V AC outdoor type with decorative post for 360 degree indirect light IP-65 protection with impact and corrosion resistant complete with driver and LED lamp all as specified & as directed. 7 M & L for GI Pipe medium grade 40 mm dia of 2.0 Mtr long complete with 50cm in ground cast iron / MS iron base plate welded to the bottom of GI pipe final taper plug bolts, nuts, screwsincluding two coats of bituminous paint internally and externally for the portion embedded in concreteincluding excavation and earth work in any type of soil,PCC (1:4:8 ) type D-2for foundation,PCC (1:2:4) type B-1 for pedestal and coping, complete all as specified and directed including taking down old one. 8 S&F in replacement LED drivers suitable for any cap and make street light complete all as specified and directed. 9 S&F in replacement surge protection device 10 KV for LEDlight fitting complete all as specified & directed. 10 S&F in replacement cable FRLS, PVC insulated and PVC sheathed size 1.5 sqmm three core multistranded copper conductor cable inclding PVC wire connectors complete all as specified & directed. 11 S&F in replacement cable FRLS, PVC insulated and PVC sheathed size 4 sqmm three core multistranded copper conductor cable inclding PVC wire connectors complete all as specified & directed. 12 S&F in replacement 20mm rigid non-metallic PVC conduit inclusive of all tees, bends,elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, locknuts, saddles, pipe hooks etc. complete all as specified & directed. 13 S&F in replacement MCB TPN of capacity 40A to 100A,10 KA, type C,240 volts complete all as specified and directed. 14 S&F in replacement MCBSPN of capacity 6A to 32A , 10 KA, type C, 240 volts complete all as specified and directed. 15 M&L for preparation of old painted surface of steel tubular LT poles 9m long and applying two coats of synthetic enamel paint with black and white or yellow strips 30cm wide each upto 1.5m height from top of PCC foundation block and on remaining surface of steel pole applying one coat of aluminium paint after preparation of old steel surfaces including marking of numbering of poles with synthetic enamel paint white in colour in 80mm high letters over 150mm x 230mm yellow base and applying one coat of cement base paint on PCC pedestal complete all as specified and directed. 16 Excavation in trenches in soft/loose soil n exc 1.50 meter wide and n exc 1.50 meter in depth for foundation of pole,laying cable etc and getting out etc complete all as specified and directed. 17 `-do- all as per Item No.16 above but insoft disintegreted rock/ laterite rock/bituminous road 18 Returning, filling in including spreading, leveling, watering and well ramming in layers n exc 25 cm thick etc complete all as specified and directed. 19 Removing excavated surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point etc complete all as specified and directe. 20 Taking up bricks laid as cable covers and stacking serviceable brick for reuse at site etc complete all as specified and directed. 21 Laying only old bricks retrieved from item Srl Item No. 20.00 (here-in-before) as cable covers in trenches etc complete all as specified and directed. 22 M&L for brick covering to underground electric cable using sub class ‘B’ bricks, laid dry, flat, perpendicular to the direction of cable etc complete all as specified and directed. . 23 M&L for Sand cushioning 230mm thickness withdry sand (one layer of 80mm thickness before laying of cable and other layer of 150mm thickness after laying of cable) andpunned down to 180mm after laying of cablein trenches for protection of cable completeall as directed.Note :- For the purpose of payment only punned thickness shall be measured. 24 Taking out the old unserviceable LT underground cable upto 16 Sqmm 1100 volts grade, XLPE insulated and PVC sheathed, armoured heavy duty with multistrand aluminium conductors from trenches/wall/floor/road/ culverts or pole etc including brick cover complete all as specified and directed.Note : Excavation and earth work, duct work, GI pipe for laying of cable and sand cushing/cable protection covers etc are beyond the scope of this item and shall be measured & paid for separately under relevant items of BoQ. 25 Supply , laying,jointing, testing and commissioningof size 10 sqmm 4 core LT underground cable , 1100 volts grade, XLPE insulated and PVC sheathed, armoured heavy duty with multistrand aluminium conductors IS-7098, laid in trenches /fixed on wall /floor /road /culverts /pole or encased in GI pipe complete all as specified and directed.Note : Excavation, earth work, sand cushion & brick protection shall be paid separately. 26 All as per item No 25.00 (here-in-before) but 16 Sqmm 4 core. 27 S&F in replacement Galvanized iron tubing, 40mm bore light grade, ISImarked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls with required size of flat iron (40mmx6mm) clamps, bolts, nuts and washers for protection of LT electric cable complete. Note :- Excavation & earthwork shall be measured & paid for separately. 28 M&L for PCC (1:2:4) type B-1 using 20 mm crushed graded stone aggregate as in coping and the like including weathering slightly rounded or chamfered angles etc complete all as specified and directed. 29 Prunning / trimming the branches of trees if any along overhead line, 3 mtr on all side below/ above/ sides of overhead line and removing the same upto 150 mtr away each span not exceeding 70 mtr etc complete all as specified and directed.Note :- The above is to be ensured for the entire contract period by cutting/trimming of trees any number of times as required. 30 S&F in replacement 10 W LED bollard lightin cylindrical shape, high surge protection, integrated LED driver , high durablity withIP-66 complete all as specified & directed. 31 Supply & fixing in repair Nature Switch control panel (using Infrared Sensor technology) for Automatic switching of Street Light. The Panel should be suitable enough to take 3-phase load of 3-5KW. Nature Switch operation should be based on Natural Light Lux level ie requiredIlluminance Level for Switching ON is = 60 Lux and for Switching OFF = 10 Lux. TheSensor should also have part night operation facility of min. 4 hrs to max. 12 hrs.The Sensor along with suitable Power Contactor(s) and Incoming-Outgoing MCBsshould be enclosed in a pole/wall mountable FR grade thermoplastic polycarbonate Enclosure (with HINGED LID) conforming to IP66 protection class 2. The circuit should also have provision for Manual Operation (i.e. Sensor By-Pass option). The Circuit should be suitable enough to take 3 nos. Contactors of 16 Amps/ phase rating, 3 nos. Incoming MCBs & 3 nos. Outgoing MCBs of 16-20 Amps each & Circuit wiring (Copper) of min.10 sq.mm complete all as specified and directed 32 Supply & fixing in repair Nature Switch sensor (using Infrared Sensor technology) for Automatic switching of Street Light. Nature Switch operation should be based on Natural Light Lux level ie required Illuminance Level for Switching ON is = 60 Lux and for Switching OFF = 10 Lux. TheSensor should also have part night operation facility of min. 4 hrs to max. 12 hrs in acrylic juction box complete all as specified and directed 33 Supply, install, testing and commissioning of LT Feeder pillar distribution panel board CPRI approved outdoor type, horizontal type, double door system, weather proof, dust and vermin proof, made out of 40x40x6mm angle iron frame and 3.15mm thick CRCA sheet duly powder coated of suitable size with push type locking arrangement, factory assembled cubicle pattern modular and compartmentalized construction, floor mounted free standing type, 3 phase 4 wire system including wiring with suitable size rated current carrying capacity aluiminium bus bar with epoxy insulated coating with colour code and insulated support, complete with following accessories and suitable for accomodate the following MCBs etc complete and mounting the panel board on ground with PCC(1:3:6) bedding upto height of 30 cm above ground level complete all as specified and as directed(a)150 Amps aluminium bus bar for all three phases and 100 Amps for neutral - 01 set.(b) MCB 63A TPN as incoming - 01 No(c) MCB SPN 32 upto 05 Nos(d) Internal All links with copper conductor or solid aluminum bus bar of adequate capacity -01 34 S&F in replacement round surface mounted12W LED panel PDC aluminium housing and hightranslucent frosted plastic diffuser make it a robust Luminaire Efficiency 100LM/w complete all as specified & directed. Make : Crompton cat Part No LCDSPLN-R-12-NW

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 27-Jan-2023 CWE/HSR-42 OF 2022-23 Date 10-02-2023
2 03-Feb-2023 CWE/HSR-42 OF 2022-23 BOQ BOQ 10-02-2023
3 10-Feb-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 17-02-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 99900.0 /-
Tender Value
INR 49.94 Lakhs /-

BOQ Items

Name of Work :REPAIR/MAINT OF FLOOD LIGHTS, HIGH MAST LIGHTS, STREET LIGHT CABLES, FEEDER PILLER BOXES, SWITCH GEAR AND CONNECTED ITEMS UNDER GE HISAR
Sl. No. Item Description
1S&F in replacement high mast light fitting of any type with LED flood light fitting of cap 120 Watt, 240 Volts, energy saving, environmental friendly, long life, exclusive innovative, die cast aluminium IP66 flood light suitable for highlighting architectural facade and general purpose lighting complete with accessories, pre-wired upto a terminal block and mounting attachment complete all as specified and directed.
2S&F in replacementLED flood light fitting of cap 100 Watt, 240 Volts, energy saving, environmental friendly, long life, exclusive innovative, die cast aluminium IP66 flood light suitable for highlighting architectural facade and general purpose lighting complete with accessories, pre-wired upto a terminal block and mounting attachment complete all as specified and directed.
3S&F in replacementLED flood light fitting of cap 70Watt, 240 Volts, energy saving, environmental friendly, long life, exclusive innovative, die cast aluminium IP66 flood light suitable for highlighting architectural facade and general purpose lighting complete with accessories, pre-wired upto a terminal block and mounting attachment complete all as specified and directed.
4Supply and fixing in repairs LED highbay light 100 W suspended or surface type with very high efficiency in PDC housing suitable for sheds. The luminaire has efficacy upto 150Lm/W with Ingress protection of IP66 including connecting 3 core copper wire complete all as specified and directed
5S&F in replacement post top LED lantern of capacity 20 Watt complete, 230 V AC outdoor type with decorative post for 360 degree indirect light IP-65 protection with impact and corrosion resistant complete with driver and LED lamp all as specified & as directed.
6S&F in replacement post top LED lantern of capacity 40 Watt complete, 230 V AC outdoor type with decorative post for 360 degree indirect light IP-65 protection with impact and corrosion resistant complete with driver and LED lamp all as specified & as directed.
7M & L for GI Pipe medium grade 40 mm dia of 2.0 Mtr long complete with 50cm in ground cast iron / MS iron base plate welded to the bottom of GI pipe final taper plug bolts, nuts, screwsincluding two coats of bituminous paint internally and externally for the portion embedded in concreteincluding excavation and earth work in any type of soil,PCC (1:4:8 ) type D-2for foundation,PCC (1:2:4) type B-1 for pedestal and coping, complete all as specified and directed including taking down old one.
8S&F in replacement LED drivers suitable for any cap and make street light complete all as specified and directed.
9S&F in replacement surge protection device 10 KV for LEDlight fitting complete all as specified & directed.
10S&F in replacement cable FRLS, PVC insulated and PVC sheathed size 1.5 sqmm three core multistranded copper conductor cable inclding PVC wire connectors complete all as specified & directed.
11S&F in replacement cable FRLS, PVC insulated and PVC sheathed size 4 sqmm three core multistranded copper conductor cable inclding PVC wire connectors complete all as specified & directed.
12S&F in replacement 20mm rigid non-metallic PVC conduit inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. complete all as specified & directed.
13S&F in replacement MCB TPN of capacity 40A to 100A,10 KA, type "C",240 volts complete all as specified and directed.
14S&F in replacement MCBSPN of capacity 6A to 32A , 10 KA, type "C", 240 volts complete all as specified and directed.
15M&L for preparation of old painted surface of steel tubular LT poles 9m long and applying two coats of synthetic enamel paint with black and white or yellow strips 30cm wide each upto 1.5m height from top of PCC foundation block and on remaining surface of steel pole applying one coat of aluminium paint after preparation of old steel surfaces including marking of numbering of poles with synthetic enamel paint white in colour in 80mm high letters over 150mm x 230mm yellow base and applying one coat of cement base paint on PCC pedestal complete all as specified and directed.
16Excavation in trenches in soft/loose soil n exc 1.50 meter wide and n exc 1.50 meter in depth for foundation of pole,laying cable etc and getting out etc complete all as specified and directed.
17`-do- all as per Item No.16 above but insoft disintegreted rock/ laterite rock/bituminous road
18Returning, filling in including spreading, leveling, watering and well ramming in layers n exc 25 cm thick etc complete all as specified and directed.
19Removing excavated surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point etc complete all as specified and directe.
20Taking up bricks laid as cable covers and stacking serviceable brick for reuse at site etc complete all as specified and directed.
21Laying only old bricks retrieved from item Srl Item No. 20.00 (here-in-before) as cable covers in trenches etc complete all as specified and directed.
22M&L for brick covering to underground electric cable using sub class ‘B’ bricks, laid dry, flat, perpendicular to the direction of cable etc complete all as specified and directed. .
23M&L for Sand cushioning 230mm thickness withdry sand (one layer of 80mm thickness before laying of cable and other layer of 150mm thickness after laying of cable) andpunned down to 180mm after laying of cablein trenches for protection of cable completeall as directed. Note :- For the purpose of payment only punned thickness shall be measured.
24Taking out the old unserviceable LT underground cable upto 16 Sqmm 1100 volts grade, XLPE insulated and PVC sheathed, armoured heavy duty with multistrand aluminium conductors from trenches/wall/floor/road/ culverts or pole etc including brick cover complete all as specified and directed. Note : Excavation and earth work, duct work, GI pipe for laying of cable and sand cushing/cable protection covers etc are beyond the scope of this item and shall be measured & paid for separately under relevant items of BoQ.
25Supply , laying,jointing, testing and commissioningof size 10 sqmm 4 core LT underground cable , 1100 volts grade, XLPE insulated and PVC sheathed, armoured heavy duty with multistrand aluminium conductors IS-7098, laid in trenches /fixed on wall /floor /road /culverts /pole or encased in GI pipe complete all as specified and directed. Note : Excavation, earth work, sand cushion & brick protection shall be paid separately.
26All as per item No 25.00 (here-in-before) but 16 Sqmm 4 core.
27S&F in replacement Galvanized iron tubing, 40mm bore light grade, ISImarked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls with required size of flat iron (40mmx6mm) clamps, bolts, nuts and washers for protection of LT electric cable complete. Note :- Excavation & earthwork shall be measured & paid for separately.
28M&L for PCC (1:2:4) type B-1 using 20 mm crushed graded stone aggregate as in coping and the like including weathering slightly rounded or chamfered angles etc complete all as specified and directed.
29Prunning / trimming the branches of trees if any along overhead line, 3 mtr on all side below/ above/ sides of overhead line and removing the same upto 150 mtr away each span not exceeding 70 mtr etc complete all as specified and directed. Note :- The above is to be ensured for the entire contract period by cutting/trimming of trees any number of times as required.
30S&F in replacement 10 W LED bollard lightin cylindrical shape, high surge protection, integrated LED driver , high durablity withIP-66 complete all as specified & directed.
31Supply & fixing in repair Nature Switch control panel (using Infrared Sensor technology) for Automatic switching of Street Light. The Panel should be suitable enough to take 3-phase load of 3-5KW. Nature Switch operation should be based on Natural Light Lux level ie required Illuminance Level for Switching ON is = 60 Lux and for Switching OFF = 10 Lux. The Sensor should also have part night operation facility of min. 4 hrs to max. 12 hrs. The Sensor along with suitable Power Contactor(s) and Incoming-Outgoing MCBs should be enclosed in a pole/wall mountable FR grade thermoplastic polycarbonate Enclosure (with HINGED LID) conforming to IP66 protection class 2. The circuit should also have provision for Manual Operation (i.e. Sensor By-Pass option). The Circuit should be suitable enough to take 3 nos. Contactors of 16 Amps/ phase rating, 3 nos. Incoming MCBs & 3 nos. Outgoing MCBs of 16-20 Amps each & Circuit wiring (Copper) of min.10 sq.mm complete all as specified and directed
32Supply & fixing in repair Nature Switch sensor (using Infrared Sensor technology) for Automatic switching of Street Light. Nature Switch operation should be based on Natural Light Lux level ie required Illuminance Level for Switching ON is = 60 Lux and for Switching OFF = 10 Lux. The Sensor should also have part night operation facility of min. 4 hrs to max. 12 hrs in acrylic juction box complete all as specified and directed
33Supply, install, testing and commissioning of LT Feeder pillar distribution panel board CPRI approved outdoor type, horizontal type, double door system, weather proof, dust and vermin proof, made out of 40x40x6mm angle iron frame and 3.15mm thick CRCA sheet duly powder coated of suitable size with push type locking arrangement, factory assembled cubicle pattern modular and compartmentalized construction, floor mounted free standing type, 3 phase 4 wire system including wiring with suitable size rated current carrying capacity aluiminium bus bar with epoxy insulated coating with colour code and insulated support, complete with following accessories and suitable for accomodate the following MCB"s etc complete and mounting the panel board on ground with PCC(1:3:6) bedding upto height of 30 cm above ground level complete all as specified and as directed (a)150 Amps aluminium bus bar for all three phases and 100 Amps for neutral - 01 set. (b) MCB 63A TPN as incoming - 01 No (c) MCB SPN 32 upto 05 Nos (d) Internal All links with copper conductor or solid aluminum bus bar of adequate capacity -01
34S&F in replacement round surface mounted12W LED panel PDC aluminium housing and hightranslucent frosted plastic diffuser make it a robust Luminaire Efficiency 100LM/w complete all as specified & directed. Make : Crompton cat Part No LCDSPLN-R-12-NW