Providing Of Ph-I Of Otm Accn For Mech Inf Bn At Ferozepur Under Ge (East) Ferozepur Cantt, jalandhar-Punjab

Military Engineer Services-MES has published Providing Of Ph-I Of Otm Accn For Mech Inf Bn At Ferozepur Under Ge (East) Ferozepur Cantt. Submission Date for this Tender is 13-02-2023. Prime Mover Tenders in jalandhar Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

35740784
Corrigendum : Providing Of Ph-I Of Otm Accn For Mech Inf Bn At Ferozepur Under Ge (East) Ferozepur Cantt
Open Tender
Indian
Punjab
jalandhar
13-02-2023

Tender Details

Providing Of Ph-I Of Otm Accn For Mech Inf Bn At Ferozepur Under Ge ( East ) Ferozepur Cantt-- 1 Note: (i) Please refer Schedule A Notes given on serial page No. 21 to 27 of tender documents. 2 LUMPSUM/ OTHER PRE-PRICED PROVISIONAL SCHEDULES OF WORKS 3 Lump sum price worked out by the contractor for BUILDING WORKS as listed in Schedule A Part-I brought forward from serial page No. 29. 4 Lump sum price worked out by the contractor for SITE CLEARANCE AND EARTHWORKS as listed in Schedule A Part-II brought forward from serial page No. 30. 5 Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION WORKS as listed in Schedule A Part-III brought forward from serial page No. 37. 6 Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY WORKS as listed in Schedule A Part-IV brought forward from serial page No. 38. 7 Lump sum price worked out by the contractor for SEWAGE DISPOSAL WORKS as listed in Schedule A Part-V brought forward from serial page No. 40. 8 Lump sum price worked out by the contractor for ROAD, PATHAND CULVERTS WORKS as listed in Schedule A Part-VI brought forward from serial page No. 42. 9 Lump sum price worked out by the contractor for AREA DRAINAGE WORKS listed in Schedule A Part-VII brought forward from serial page No. 43. 10 Lump sum price worked out by the contractor for BOUNDARY WALL, COMPOUND WALL,FENCING AND GATE WORKS listed in Schedule A Part-VIII brought forward from serial page No. 45. 11 Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLYWORKS as listed in Schedule A Part-IX brought forward from serial page No. 46. 12 Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATIONWORKS as listed in Schedule A Part-X brought forward from serial page No. 50. 13 Lump sum price worked out by the contractor for DG SET WORKS as listed in Schedule A Part-XI brought forward from serial page No. 51. 14 Lump sum price worked out by the contractor for SUMMER APPLIANCES WORKSas listed in Schedule A Part-XII brought forward from serial page No. 53. 15 Lump sum price worked out by the contractor for RAIN WATER HARVESTING WORKSas listed in Schedule A Part-XIII brought forward from serial page No. 54. 16 Lump sum price worked out by the contractor for HOT WATER SUPPLY WORKS as listed in Schedule A Part-XIV brought forward from serial page No. 56. 17 Lump sum price worked out by the contractor forLIGHTENING CONDUCTOR WORKS as listed in Schedule A Part-XV brought forward from serial page No. 57. 18 Lump sum price worked out by the contractor for BORE WELL WORKS as listed in Schedule A Part-XVI brought forward from serial page No. 58. 19 Lump sum price worked out by the contractor for STP WORKS as listed in Schedule A Part-XVII brought forward from serial page No. 59. 20 Lump sum price worked out by the contractor for TREATED SEWAGE WATER SUPPLY WORKS as listed in Schedule A Part-XVIII brought forward from serial page No. 60. 21 Lump sum price worked out by the contractor for PCC HARD STANDING WORKS as listed in Schedule A Part-XIX brought forward from serial page No. 61. 22 SCHEDULE A PART-XX MISC ITEMS INTERNAL ELECTRIFICATION WORKS 23 Supply and Fix energy efficient LED bulb, B229 Watt complete all as specified and directed. Make:- Cat No LHLDBWEB4L8R009 of Havells or eqvt in Philips and CG. 24 Supply and Fix Modular RJ telephone socketcomplete all as specified and directed by Engr -in- Charge. Make:- Cat No / SAP code AHLKHWW000 of Havells or eqvt in Legrand/ Schneider. 25 Supply and Fix Modular TV Socket complete all as specified and directed by Engr -in- Charge.Cat No /SAP code AHLKT0W000 of Havells or eqvt in Legrand/ Schneider. 26 Supply and FixDecorative 9W LEDwall mounting fittings complete set including 9 W LED lamp all as specified and directed. Make:- Cat No LHF0ECEITZIB014 Glaze Wall Light of Havellsor eqvt in Philips / Crompton. 27 S&F GI pipe bracket made out of GI pipe light grade 32 mm dia and bend to shape 1.5 mtr long MS clamps made out of MS flat iron of size 25x4 mm thick with nuts & bolts, washers complete as specified and directed 28 Supply and fix wall mounting fan industrial type 450mm sweep, 230V, 50Hz , 1400 RPM, 100W, 150cum/hr air delivery, copper motor, double ball bearing , 60dB - 65dB nosie level, upward and down adjustable, 60 degree oscillation degree, 3 Nos metal balde guarded with 112 spokes metal case complete with mountings accessories kit, wall bracket, nut, bolt washer etc with connection PVC three core copper wire all as specified and directed. Make:- Cat No FHACWSTSCL18 of Havells or eqvt in Legrand/ Philips. 29 SEWAGE DISPOSAL WORKS 30 Material and labour for laying DWC HDPE 150mm (I/D) SN8 pipe including all necessary fittings for carrying sewage complete all as directed by Engineer in Charge. 31 Material and labour for laying DWC HDPE 200mm (I/D) SN8 pipe including all necessary fittings for carrying sewage complete all as directed by Engineer in Charge. 32 Material and labour for construction of under gournd sump cum pump house complete all as shown on drawings and as specified. (Drg No CEJZ-04/2000 Sheet No. 1/2 to 2/2). 33 ROAD, PATHAND CULVERTS WORKS 34 Material and labour for cat eye abs plastic with nail of size 100mm x 100mm, 20mm reflective glass colour White/ Red/ Yellow provided with steel zinc plated with bolt of 12mm dia length 120mm for fixing on road by hammering complete all as directed by Engineer in Charge. 35 Material and labour for delineator 47mm dia 600mm long with high intensity reflective sheeting complete all as directed by Engineer-in-Charge. 36 EXTERNAL WATER SUPPLY WORKS 37 Supplying, laying, jointing and testing in trenches centrifugally cast 150mm bore ductile iron pipe class K-7 conforming to IS : 8329-2000 of min wall thickness 5.4mm including testing complete all as specified. 38 Supplying, laying, jointing and testing in trenches centrifugally cast 100mm bore ductile iron pipe class K-7 conforming to IS : 8329-2000 of min wall thickness 5.4mm including testing complete all as specified Notes for Srl No. 6.01 & 6.02 :-(a) Excavation, earth work and DI fittings shall be measured and paid for separately under respective items(b) Cost of tyton joints is included in the rate quoted.(c) Standard length of the pipe should be 5.50m or 6.0m as available.(d) The measurement of the pipe shall be net as fixed between the fittings including short length without any allowance for cutting and wastage and for the portion entering in the socket of all pipes and fittings.(e) Predespatch inspection & testing of DI pipe shall be carried out by the representative of AO. All the expenditure for the same shall be borne by the contractor and the quoted rates shall be deemed to be included for the same 39 Supply, fixing and testing ductile iron fittings such as bends (any type radius and angle) tapers any type (straight, bend, increasing, decreasing or double socket etc) tee pieces single branch ‘Y’ junction. Double branch, cross (all sockets or sockets and spigot) collars, tail pieces with one end flanged (integrally cast) and one end socket. Spigot caps and plugs suitable for 100 to 150mm ductile iron pressure pipes of K-7 classification and push on flexible rubber gasket joints complete all as specified and directedNotes :(a) DI fittings shall be of same make as of DI pipes or of make as recommended by manufacturers(b) The weight of the fittings shall be measured and paid as given in relevant IS or actually provided whichever is less.(c) All fittings shall be relevant IS stamping marking.(d) Excavation and earth work shall be measured and paid for separately.(e) Cost of the joints and jointing materials shall be deemed to be included in the relevant items of DI pipes here-in-before 40 Construction of brick masonary valve pit chamber of 1050mm x 750mm x 1000mm size (internal dimensions) with MS sheet cover 6mm thick and angle iron 40mm x 40mm x 6mm frame duly painted with two coat of synthetic enamel paint over one coat of red oxide primer including locking arrangement, necessary earth work etc complete all as specified and shown on drgs. Breakdown of QtyExternal Water Supply-4 (Each)Treated Sewage Water Supply-2 (Each) 41 Construction of brick masonary valve pit chamber of 900 x 900 x 1000mm size (internal dimensions) with MS sheet cover 6mm thick and angle iron 40 x 40 x 6mm frame duly painted with two coat of synthetic enamel paint over one coat of red oxide primer including locking arrangement, necessary earth work etc complete all as specified andshown on drgs. Breakdown of QtyExternal Water Supply-5 (Each)Treated Sewage Water Supply-3 (Each) 42 Construction of brick masonary valve pit chamber of 600mm x 600mm x 1000mm size (internal dimensions) with MS sheet cover 6mm thick and angle iron 40mm x 40mm x 6mm frame duly painted with two coat of synthetic enamel paint over one coat of red oxide primer including locking arrangement, necessary earth work etc complete all as specified andshown on drgs. Note for Srl item No. 6.04 to 6.06:- 43 Supply and fixing RCC water main route indicator of size 75cm x 40cm x 10cm duly marked with MES Water Mains Bore made of cement concrete (1:2:4) type B-1 as in foundation of electric poles/ struts etc including necessary form work, fair, finished embedded in PCC bed including necessary excavation and re-filling, proposed to be installed after 25m on pipe lines of size 150mm, 100mm, 80mm and 50mm complete all as directed by Engineer-in-Charge. 44 EXTERNAL ELECTRIC SUPPLY WORKS 45 Supply ,install, testing and commissioning power factor control LT panel board (APFC) of 200 KVAR, 433 volt, 50 Cycle per second cubical type front and back openable double leaf type dust & vermin proof with locking arrangement powder coated with approved colour , made out of CRCA sheet 14 SWG, outdoor herewith canopy, cable entry glands, double compressor type, duly prewired with suitable pillar made out of 50 mmx 50mm x6 mm angle iron grouted in and including PCC (1:2:4) using 20 mm graded stone aggregate complete all as per IS 8623-1933 & all as per latest ISI specification and suitable for housing and including following accessories :- (a) Incoming MCCB of 250 Amps 36 KA rupturing capacity , 3 Pole thermal magnetic release type shunt trip coil -01 No (b) Copper Bus bar duly insulated with colour coded heat shrinkable sleeve insulation for three phase four wire system of 250 Amps capacity rating with suitable size/ type on hygroscopic on combustion track resistance, high strength FRP/MC/DMC insulators.(c) Capacitor switching contactor of suitable capacity (contractor amps rating shell not be less than 1.5 times nominal current rating, three pole, coil voltage 440 Volts, one each for number of capacitor bank , each contractor shell be protected with 10 KA , d curve type (MCB to be provided for 1.33 times KVAR i.e. 100 % current capacity of the MPFCS irrespective of the fact that contractor’s rating is 1.5 times) (MCCB 25 KA shall be provided for the above 63 Amps rating)(d) One set current transformer (CTs) of suitable ratio (with secondary of 5 Amps ) to be fixed on bus bar of existing panel including connection with 2 core 1.5 Sqmm armoured copper conductor complete with gland etc.(e) Shunt capacitor MPP type heavy duty 200 KVAR distributed in step of 6 steps with configuration (2x12.5 + 1x25 + 3x50) directly connected to maintain power factor at 0.99 or unity, housed in self-extinguishing insulated material with built in. 46 Supply and fixing 3 core 1.5 sqmm PVC insulated and FRLS PVC round sheathed copper conductor flexible 1100 volts for connection from Junction Box to street light fittings complete all as specified and directed. Make :Polycab/ Havells/ Finolex/ Paragon 47 Supply and fixing street light pole cable junction box IP-65 with metric knockouts for cable entry with MCB SP 6 Amps,10 KA and the box made out of thermal plastic material suitable for 16/25 Sqmm UG cable including clamps bolts, nuts, duly painted etc complete all as and directed by Engineer-in-Charge. 48 Supply and fixing bracket made out of 40 mm dia GI light grade tubing 1.2 meter long and bent to angle /shape of 120 degree angle at the meddle from vertical fixed with clamps nuts and bolts washers complete all as specified and directed 49 Supply and fixing automatic street light switchfor automatic switching of street light/high mast light (timer switch)for Three Phase Loadlight.The Digital timer 24 hrs alongwith suitable power contractor as per IEC - 60947-4-1, including incoming & outgoing MCBs, SMC Enclosure and support terminal and enclosed in pole/wall mounted factory made PVC enclosure made out of rust proof, shock & termite proof and FRLS grade confirming to IP-54 of capacity 6 KW, Three phase, Current rating 32/TP and MCB rating 40/TPN, having facility of manual operation complete all as directed by Engineer-in-Charge. 50 Supply, installation, testing and commissioning of CPRI approved, factory made, LT panel board cubical, Outdoor type, floor mounted double door, Front & Rear openable with locking arrangement, suitable for AC,3 phase, 4 wire, 50 cycles, 415 Volts. The panel board shall be made of 3.15 thick CRCA/MS sheet (Min size 1.8 m x 1.5 m x 1.0 m) painted with Synthetic enamel Paint both side. The panel have to provide proper compartment as per IS specification and wiring of panel with suitable size of copper conductor FRLS cable not less than 2.5 Sqmm with thimbles all as directed. Base frame of the panel shall bemade of angle iron of size 50 x50 x 6mm of upto 1/2 mtr height from GL & 1/2 mtr below GL in PCC (1:3:6) type C-2 using 40 mm graded stone aggregates comprising of following:-Location - Main Panel (X-Mer - 400 KVA)(i) Panel having common aluminium bus bar of capacity 1600 Amp TPN each and suitable capacity TPN bus bar for outgoing MCCBs, including aluminium lugs to connect the cable and cable gland for Each cable entry as per cable size.(ii) INCOMING(a)ACB Microprocessor released and thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 800 Amp 4 Pole, 50 KAwith overload variation 40-100%- 1 No,(iii) OUTGOING(a)MCCB thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 250 Amp 3 Pole, 35 KA with overload variation 40-100%- 1 No,(for APFC ) (b)-do- but 250 Amp - 1 No, (c)-do- but 160 Amp - 1 No, (d)-do- but 125 Amp - 02 Nos,(e)-do- but 63 Amp - 6 Nos,(iv)Volt Meter 0 - 500 Volts digital type square shapeflush mounted with selector switch - 1 No.(v)Ammeter 0 - 800 Amps digital type square shape 96mm flush mounted with selector switch and CTs 800/5 A - 1 No.(vi) Phase indicating lamp LED TYPE 03 Nos 51 Supply, installation, testing and commissioning of CPRI approved, factory made, LT panel board cubical, Outdoor type, floor mounted double door, Front & Rear openable with locking arrangement, suitable for AC,3 phase, 4 wire, 50 cycles, 415 Volts. The panel board shall be made of 3.15 thick CRCA/MS sheet (Min size 1.6 m x 1.35 m x 0.8 m) painted with synthetic enamel paint both side. The panel have to provide proper compartment as per IS specification and wiring of panel with suitable size of copper conductor FRLS cable not less than 2.5 Sqmm with thimbles all as directed. Base frame of the panel shall bemade of angle iron of size 50 x50 x 6mm of upto 1/2 mtr height from GL & 1/2 mtr below GL in PCC (1:3:6) type C-2 using 40 mm graded stone aggregates comprising of following:-Location - Near SMBK(i) Panel having common aluminium bus bar of capacity 500 Amp TPN each and suitable capacity TPN bus bar for outgoing MCCBs, including aluminium lugs to connect the cable and cable gland for Each cable entry as per cable size.(ii) INCOMING(a)MCCB thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 250 Amp 4 Pole, 35 KAwith overload variation 40-100%- 1 No.(iii) OUTGOING(a)MCCB thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 63 Amp 4 Pole, 16 KA with overload variation 40-100%- 4 Nos. (b)-do- but 32 Amp - 2 Nos, (iv)Volt Meter 0 - 500 Volts digital type square shapeflush mounted with selector switch - 1 No.(v)Ammeter 0 - 250 Amps digital type square shape 96mm flush mounted with selector switch and CTs 250/5 A - 1 No.(vi) Phase indicating lamp LED TYPE 03 Nos 52 Supply, installation, testing and commissioning of CPRI approved, factory made, LT panel board cubical, Outdoor type, floor mounted double door, Front & Rear openable with locking arrangement, suitable for AC, 3 phase, 4 wire, 50 cycles, 415 Volts. The panel board shall be made of 3.15 thick CRCA/MS sheet (Min size 1.6 m x 1.35 m x 0.8 m) painted with synthetic enamel paint both side. The panel have to provide proper compartment as per IS specification and wiring of panel with suitable size of copper conductor FRLS cable not less than 2.5 Sqmm with thimbles all as directed. Base frame of the panel shall bemade of angle iron of size 50 x50 x 6mm of upto 1/2 mtr height from GL & 1/2 mtrbelow GL in PCC (1:3:6) type C-2 using 40 mm graded stone aggregates comprising of following:-Location - Near JCO MESS(i) Panel having common aluminium bus bar of capacity 320 Amp TPN each and suitable capacity TPN bus bar for outgoing MCCBs, including aluminium lugs to connect the cable and cable gland for Each cable entry as per cable size.(ii) INCOMING(a)MCCB thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 160 Amp 4 Pole, ICU=ICS=35 KAwith overload variation 40-100%- 1 No.(iii) OUTGOING(a) MCCB thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 80 Amp 4 Pole, ICU=ICS=25 KA with overload variation 40-100%-1 No. (b)MCCB thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 32 Amp 4 Pole, ICU=ICS=16 KA with overload variation 40-100%- 4 Nos. (c)MCB isolator 25 Amp SPN 10 KA, 240V-01 No, (iv)Volt Meter 0 - 500 Volts digital type square shapeflush mounted with selector switch - 1 No.(v)Ammeter 0 - 160 Amps digital type square shape 96mm flush mounted with selector switch and CTs 160/5 A - 1 No.(vi) Phase indicating lamp LED TYPE 03 Nos 53 Supply, installation, testing and commissioning of CPRI approved, factory made, LT panel board cubical, Outdoor type, floor mounted double door, Front & Rear openable with locking arrangement, suitable for AC, 3 phase, 4 wire, 50 cycles, 415 Volts. The panel board shall be made of 3.15 thick CRCA/MS sheet (Min size 1.6 m x 1.35 m x 0.8 m) painted with synthetic enamel paint both side. The panel have to provide proper compartment as per IS specification and wiring of panel with suitable size of copper conductor FRLS cable not less than 2.5 Sqmm with thimbles all as directed. Base frame of the panel shall bemade of angle iron of size 50 x50 x 6mm of upto 1/2 mtr height from GL & 1/2 mtr below GL in PCC (1:3:6) type C-2 using 40 mm graded stone aggregates comprising of following:-Location - Near Offr MESS(i) Panel having common aluminium bus bar of capacity 250 Amp TPN each and suitable capacity TPN bus bar for outgoing MCCBs, including aluminium lugs to connect the cable and cable gland for Each cable entry as per cable size.(ii) INCOMING(a)MCCB thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 125 Amp 4 Pole, ICU=ICS=25 KAwith overload variation 40-100%- 1 No.(iii) OUTGOING(a)MCCB thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 63 Amp 4 Pole, ICU=ICS=16 KA with overload variation 40-100%- 2 Nos. (b)MCCB thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 32 Amp 4 Pole, ICU=ICS=25 KA with overload variation 40-100%- 2 Nos. (c)MCB isolator 32 Amp SPN 10 KA, 240V-04 Nos, (iv)Volt Meter 0 - 500 Volts digital type square shapeflush mounted with selector switch - 1 No.(v)Ammeter 0 - 125 Amps digital type square shape 96mm flush mounted with selector switch and CTs 125/5 A - 1 No.(vi) Phase indicating lamp LED TYPE 03 Nos 54 Supply, installation, testing and commissioning of CPRI approved, factory made, LT panel board cubical, Outdoor type, floor mounted double door, Front & Rear openable with locking arrangement, suitable for AC, 3 phase, 4 wire, 50 cycles, 415 Volts. The panel board shall be made of 3.15 thick CRCA/MS sheet (Min size 1.6 m x 1.35 m x 0.8 m) painted with synthetic enamel paint both side. The panel have to provide proper compartment as per IS specification and wiring of panel with suitable size of copper conductor FRLS cable not less than 2.5 Sqmm with thimbles all as directed. Base frame of the panel shall bemade of angle iron of size 50 x50 x 6mm of upto 1/2 mtr height from GL & 1/2 mtr below GL in PCC (1:3:6) type C-2 using 40 mm graded stone aggregates comprising of following:-Location - Near Adm Block(i) Panel having common aluminium bus bar of capacity 250 Amp TPN each and suitable capacity TPN bus bar for outgoing MCCBs, including aluminium lugs to connect the cable and cable gland for Each cable entry as per cable size.(ii) INCOMING(a)MCCB thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 125 Amp 4 Pole, ICU=ICS=25 KAwith overload variation 40-100%- 1 No.(iii) OUTGOING(a)MCCB thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 63 Amp 4 Pole, ICU=ICS=16 KA with overload variation 40-100%- 2 Nos. (b)MCCB thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 32 Amp 4 Pole, ICU=ICS=25 KA with overload variation 40-100%- 2 Nos. (iv)Volt Meter 0 - 500 Volts digital type square shapeflush mounted with selector switch - 1 No.(v)Ammeter 0 - 125 Amps digital type square shape 96mm flush mounted with selector switch and CTs 125/5 A - 1 No.(vi) Phase indicating lamp LED TYPE 03 Nos 55 Supply, installation, testing and commissioning of CPRI approved, factory made, LT panel board cubical, Outdoor type, floor mounted double door, Front & Rear openable with locking arrangement, suitable for AC, 3 phase, 4 wire, 50 cycles, 415 Volts. The panel board shall be made of 3.15 thick CRCA/MS sheet (Min size 1.6 m x 1.35 m x 0.8 m) painted with synthetic enamel paint both side. The panel have to provide proper compartment as per IS specification and wiring of panel with suitable size of copper conductor FRLS cable not less than 2.5 Sqmm with thimbles all as directed. Base frame of the panel shall bemade of angle iron of size 50 x50 x 6mm of upto 1/2 mtr height from GL & 1/2 mtr below GL in PCC (1:3:6) type C-2 using 40 mm graded stone aggregates comprising of following:-Location - MT area panel(i) Panel having common aluminium bus bar of capacity 200 Amp TPN each and suitable capacity TPN bus bar for outgoing MCCBs, including aluminium lugs to connect the cable and cable gland for Each cable entry as per cable size.(ii) INCOMING(a)MCCB thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 63 Amp 4 Pole, ICU=ICS=16 KAwith overload variation 40-100%- 1 No.(iii) OUTGOING(a)MCCB thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 32 Amp 4 Pole, ICU=ICS=16 KA with overload variation 40-100%- 4 Nos. (b)MCB isolator 25 Amp SPN 10 KA, 240V-10 Nos. (iv)Volt Meter 0 - 500 Volts digital type square shapeflush mounted with selector switch - 1 No.(v)Ammeter 0 - 100 Amps digital type square shape 96mm flush mounted with selector switch and CTs 100/5 A - 1 No.(vi) Phase indicating lamp LED TYPE 03 Nos 56 Supply, installation, testing and commissioning of CPRI approved, factory made, LT panel board cubical, Outdoor type, floor mounted double door, Front & Rear openable with locking arrangement, suitable for AC, 3 phase, 4 wire, 50 cycles, 415 Volts. The panel board shall be made of 3.15 thick CRCA/MS sheet (Min size 1.4 m x 1.25 m x 0.8 m) painted with synthetic enamel paint both side. The panel have to provide proper compartment as per IS specification and wiring of panel with suitable size of copper conductor FRLS cable not less than 2.5 Sqmm with thimbles all as directed. Base frame of the panel shall bemade of angle iron of size 50 x50 x 6mm of upto 1/2 mtr height from GL & 1/2 mtr below GL in PCC (1:3:6) type C-2 using 40 mm graded stone aggregates comprising of following:-Location - Street light panel(i) Panel having common aluminium bus bar of capacity 200 Amp TPN each and suitable capacity TPN bus bar for outgoing MCCBs, including aluminium lugs to connect the cable and cable gland for Each cable entry as per cable size.(ii) INCOMING(a)MCCB thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 63 Amp 4 Pole, ICU=ICS=16 KAwith overload variation 40-100%- 1 No.(iii) OUTGOING(a)MCCB thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 32 Amp 4 Pole, ICU=ICS=16 KA with overload variation 40-100%- 3 Nos. (b)ON LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 63 Amp. (iv)Volt Meter 0 - 500 Volts digital type square shapeflush mounted with selector switch - 1 No.(v)Ammeter 0 - 100 Amps digital type square shape 96mm flush mounted with selector switch and CTs 100/5 A - 1 No.(vi) Phase indicating lamp LED TYPE 03 NosNote Srl item No. 7.06 to 7.12:- LT Panel shall be got tesed from CPRI type test for 4000 Amp with breaking capacity not less than 65 KA and IP 56 as per IS 61439 Part- 1& 2. 57 Supply and fixing of rubber mat (Insulation mat) of dimension 1m x 2m and 2 mm thick complete for electrical installation and DG sets panels complete all as directed by Engineer-in-Charge. 58 Supply and fixing of rubber mat of dimension 1m x 2m and 3 mm thick complete for electrical installation and STP main panels complete all as specified and directed. 59 Supply and fixing RCC HT cable route indicator of size 75cmx40cmx10cm duly marked with HT cable made ofcement concreted (1:2:4) type B-1 as in foundation of electric poles/struts/ etc including necessary form work, fair finished embedded in PCC bed including necessary excavation and re-filling complete all as specified and directed 60 DG SET WORKS 61 Supply, installing, commissioning and testing of eco-friendly Diesel Engine driven generating set silent type confirming to CPCB conditions/ norms, 62.5 KVA, or next higher capacity as available/manufactured at 0.9 power factor directly coupled alternator & engine. The diesel set shall consist of a diesel engine coupled directly to a matching parts or as recommended/ provided by the manufacturer on a common base frame and thereafter installed in the CPCB approved acoustic enclosure. The complete set conforming to and test certificate as per CPCB norms and as specified) complete without AMF control panel standardized by manufacturer, fuel tank with mounting arrangement, flexible exhaust pipe complete with the following:-(a) Engine (Prime mover) : Diesel engine 1500 RPM of minimum 84 BHP or recommended by manufacturer turbo charged water cooled,12 volts electric battery start, complete with fly wheel and all standard fitting/ fixtures as per manufacturing practice including suitable engine control panel/ dash board with electronic technometer. lube oil temp and pressure gauges water temp gauge frequency meter (digital type) including safety self-starter, alternator, cogged V belt, fuel tank with first fill of lube oil and coolant (as applicable) etc. (b) Alternator :Alternator AC 3 phase 415 Volts 4 wire rated line current for output 62.5 KVA, PF 0.8, 1500 RPM insulation class enclosures /SPDP self-exited self-regulated brushes, complete with AVR with plus and minus voltage regulation directly coupled to and match the above engine. (c) Anti vibration pads for mounting engine, alternator assembly on base frame/plate or as recommended by the manufacturer.(d) Base plate made out of structural steel as per manufacturer recommended design/specification.(e) Acoustic enclosure of an internal type approved/certified acoustic enclosure (as per CPCB norms for the DG Set) to restrict the noise level to 75 db at one meter distance and temp rise with in canopy shall not exceed 7 degree centigradebeyond ambient temp. It shall be made of 16 SWG or manufacturer standard norms CRCA sheet with powder coated finish on outside and provided with non ignitic fire retardant foam as acoustic material. The doors and glass windows shall be ISMC. It shall also include the following:-(i) Silencer/Absorption the non-resistance, residential and exhaust pipe covered with asbestos rope.(ii) Internal wiring with PVC copper conductor cable IS-694 marked FRLS in conduit and fluorescent lamp fittings.(iii) Fuel tank of 16 hours cap but not less than made of 14 SWG CRCA sheet duly powder coated and provided with float gauge and fuel float switch.(iv) One No 12 V X 180 AH 25 plates maintenance free batteries as recommended by manufacturer.(f) The exhaust of DG set shall be fitted with emission control devises as per latest CPCB norms and as specified and also contractor shall submit test certificate of DG set as per latest CPCB norms. 62 Supply, installing, commissioning and testing of eco-friendly Diesel Engine driven generating set silent type confirming to CPCB conditions/ norms, 40 KVA, or next higher capacity as available/manufactured at 0.9 power factor directly coupled alternator & engine. The diesel set shall consist of a diesel engine coupled directly to a matching parts or as recommended/ provided by the manufacturer on a common base frame and thereafter installed in the CPCB approved acoustic enclosure. The complete set conforming to and test certificate as per CPCB norms and as specified) complete without AMF control panel standardized by manufacturer, fuel tank with mounting arrangement, flexible exhaust pipe complete with the following:-(a) Engine (Prime mover) : Diesel engine 1500 RPM of minimum 51 BHP or recommended by manufacturer turbo charged water cooled,12 volts electric battery start, complete with fly wheel and all standard fitting/ fixtures as per manufacturing practice including suitable engine control panel/ dash board with electronic technometer. lube oil temp and pressure gauges water temp gauge frequency meter (digital type) including safety self-starter, alternator, cogged V belt, fuel tank with first fill of lube oil and coolant (as applicable) etc. (b) Alternator :Alternator AC 3 phase 415 Volts 4 wire rated line current for output 40 KVA, PF 0.8, 1500 RPM insulation class enclosures /SPDP self-exited self-regulated brushes, complete with AVR with plus and minus voltage regulation directly coupled to and match the above engine. (c) Anti vibration pads for mounting engine, alternator assembly on base frame/plate or as recommended by the manufacturer.(d) Base plate made out of structural steel as per manufacturer recommended design/specification.(e) Acoustic enclosure of an internal type approved/certified acoustic enclosure (as per CPCB norms for the DG Set) to restrict the noise level to 75 db at one meter distance and temp rise with in canopy shall not exceed 7 degree centigradebeyond ambient temp. It shall be made of 16 SWG or manufacturer standard norms CRCA sheet with powder coated finish on outside and provided with non ignitic fire retardant foam as acoustic material. The doors and glass windows shall be ISMC. It shall also include the following:-(i) Silencer/Absorption the non-resistance, residential and exhaust pipe covered with asbestos rope.(ii) Internal wiring with PVC copper conductor cable IS-694 marked FRLS in conduit and fluorescent lamp fittings.(iii) Fuel tank of 16 hours cap but not less than made of 14 SWG CRCA sheet duly powder coated and provided with float gauge and fuel float switch.(iv) One No 12 V X 88 AH 25 plates maintenance free batteries as recommended by manufacturer.(f) The exhaust of DG set shall be fitted with emission control devises as per latest CPCB norms and as specified and also contractor shall submit test certificate of DG set as per latest CPCB norms. 63 SUMMER APPLIANCES WORKS 64 Supply and fixing voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170V-250V with output voltage stabilized at 230V with accuracy of ±2.5% and of capacity 1.0 KVA complete all as directed by Engineer-in-Charge. 65 Supply and fixing voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170V-250V with output voltage stabilized at 230V with accuracy of ±2.5% and of capacity 2.0 KVA complete all as directed by Engineer-in-Charge. 66 Supply and fixing voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170V-250V with output voltage stabilized at 230V with accuracy of ±2.5% and of capacity 3.0 KVA complete all as directed by Engineer-in-Charge. 67 Supply and fixing voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170-250V with output voltage stabilized at 230V with accuracy of ±2.5% and of capacity 5.0 KVA complete all as directed by Engineer-in-Charge. 68 Supply and installed refrigerators, electric driven (single phase) of capacity 220 Ltrs frost free, 5 star rated complete all as directed by Engineer-in-Charge. 69 Supply and installed refrigerators, electric driven (single phase) of capacity 400 Ltrs frost free, 5 star rated complete all as directed by Engineer-in-Charge. 70 Supply and installing desert cooler electric driven (single phase) having nominal air flow capacity of 4000 Cum/ Hrs 230V made of 20 gauge MS sheet and size not less than 90cm, 78cm x 78cm surface area from top and bottom 62cm x 54cm front grill size including tullu pump with rotary switch (4 speed) 5 Amp switch on front side, drain valve including two coats synthetic of enamel paint over a coat of primer complete all as directed by Engineer in Charge. 71 RAIN WATER HARVESTING WORKS 72 Material and labour for gravel packing including jute as filter media 4mm to 6mm size around MS pipe complete all as directed by Engineer-in-Charge. 73 Material and labour for filling of gravel in trenches of size 6mm to 10mm upto height of 0.50m complete all as directed by Engineer-in-Charge. 74 Material and labour for filling of gravel in trenches of size 2mm to 4mm upto height of 1.0m complete all as directed by Engineer-in-Charge. 75 BORE WELL WORKS 76 Material and labour for Drilling of 675mm bore hole from ground level to 20 m depth below ground levelin any strata by mechanical percussion method below ground level including electrical logging through any kind of strata soils/rocks, disposal of surplus soil keeping space for pea gravel packing and including lowering and extraction of casing pipes complete all as specified and as directed :-Notes :(a) Record shall be maintained for regular sample of cutting after every 3 metre interval to be collected and kept at site (b) The bore/tube well should be constructed by the agency as approved by GE (East) Fzr.(c) The Rates also includes transportation of Rig Machine & T&P at Site.(d) Trail Bore will be drilled, if sufficient wet strata is available then ERW casing will be lowered. In case Strata is not available payment only for drilling will be made 77 All as per Srl item No. 11.01 here-in-before but from 20 m below ground level to 40 m depth below ground level. 78 All as per Srl item No. 11.01 here-in-before but from 40 m below ground level to 60 m depth below ground level. 79 Material and labour for Drilling of 525 mm bore hole from 60 mtr below ground level to 85 mtr depth below ground level in any strata by mechanical percussion method below ground level including electrical logging through any kind of strata soils/rocks, disposal of surplus soil keeping space for pea gravel packing and including lowering and extraction of casing pipes complete all as specified and as directed :-Notes :(a) Record shall be maintained for regular sample of cutting after every 3 metre interval to be collected and kept at site (b) The bore/tube well should be constructed by the agency as approved by GE (East) Fzr.(c) The Rates also includes transportation of Rig Machine & T&P at Site.(d) Trail Bore will be drilled, if sufficient wet strata is available then ERW casing will be lowered. In case Strata is not available payment only for drilling will be made 80 All as per Srl item No. 11.04 here-in-before but from 85 m below ground level to 110 m depth below ground level. 81 All as per Srl item No. 11.04 here-in-before but from 110 m below ground level to 135 m depth below ground level. 82 Material and labour for Drilling of 450 mm bore hole from 135 mtr below ground level to 160 mtr depth below ground level in any strata by mechanical percussion method below ground level including electrical logging through any kind of strata soils/rocks, disposal of surplus soil keeping space for pea gravel packing and including lowering and extraction of casing pipes of following diameters complete all as specified and as directed :-Notes :(a) Record shall be maintained for regular sample of cutting after every 3 metre interval to be collected and kept at site (b) The bore/tube well should be constructed by the agency as approved by GE (East) Fzr.(c) The Rates also includes transportation of Rig Machine & T&P at Site.(d) Trail Bore will be drilled, if sufficient wet strata is available then ERW casing will be lowered. In case Strata is not available payment only for drilling will be made 83 All as per Srl item No. 11.07 here-in-before but from 160 m below ground level to 185 m depth below ground level. 84 All as per Srl item No. 11.07 here-in-before but from 185 m below ground level to 200 m depth below ground level. 85 Material and labour for electrical Logging of bore well and after electrical logging report of Assembly Design and submission of lithological log report for approval of GE complete. 86 Supply and fixing 350 mm bore ERW mild steel housing pipe 8mm wall thickness duly painted with primer and anti-corrosive paint with screwed and socket ends in standard length of 3 metre or as required at site, complete with coupling, welding at joints as required (ISI marked : IS-4270-1992) including cutting,lowering, jointing and fixing in position, complete all as specified (Measured net as fixed). 87 All as per Srl item No. 11.11 here-in-before but 250 mm bore pipe with 8 mm wall thickness. 88 Supply and fixing low carbon galvanised iron screen filter (slotted) 250mm bore pipe with slots 0.2 mm to 1.5 mm, 6.4mm wall thickness duly painted with ferrous primer and anti-corrosive bituminous paint including screwed and socket ends in standard length, welding and fixing support having slots 0.2 mm to 1.5 mm depending upon nature of aquifers sediments, complete including lowering and fixing in position, confirming to IS-4270-1992, complete all as specified (Measured net as fixed) 89 Supply and fixing Mild steel reducing socket for connecting 350mm bore housing pipe with 250mm bore blind pipe with minimum 8.0 mm wall thickness including welding and fixing support complete all as specified and directed 90 Supply and fixing Mild steel bail plug suitable for 250 mm bore pipe 1.5 metre long having wall thickness of 8.0 mm with strong iron hooks, complete all as specified and directed 91 Supply and fixing well cap fabricated out of 6 mm thick mild steel sheet for 350mm bore housing pipe threaded similar to housing pipe with handle made and of 20mm dia mild steel round bar, complete all as specified and directed 92 Material and labour for mild steel flat iron 75mmx6mm as centre guides (set of three), standard pattern for 350/250 mm bore housing pipe complete all as specified and directed 93 Material and labour for MS clamps made out of flat iron 125mmx12mm and 01 metre long with nut, bolts of 22mm dia of suitable length for 350mm bore housing pipe complete all as specified and directed 94 Material and labour for mild steel structural steel E-250 grade 410W (ISMB-150) fixed independently without connecting plateincluding two coats of black paint over a coat of red oxide complete all as specified and directed 95 Material and labour for Strata sample box, made out of 1st class soft wood (deodar) having appropriate internal dimensions 1000mm×600mm×100mm with open-able glass shutter using 4mm thick plain sheet glass having pigeon holes as approved, 2 Nos butt hinges of suitable size and 75mm long hasp staple 01 No having not less than 25 compartments capable of holding 480 to 540 grams of strata sample, including painting wooden surfaces with two coats of synthetic enamel paint (grey) over a coat of pink primer complete all as specified and as directed 96 Material and labour for 10mm thick (structural steel should be Fe-290 (Grade-E-165) mild steel black plate of size 600mm dia & cut into two semi-circular equal parts with 350 mm dia hole in the centre complete all as directed by Engineer-in-Charge. 97 Material and labour for pea gravel of size 1.5mm to 4.5mm packed all around 350mm bore housing pipe and 250mm bore blind pipe, strainer pipe upto entire depth as required at site in newbore-well, complete all as specified and directed.Note:- For the purpose of measurement, gravel brought by the contractor shall be stacked properly at site & measurements of stack shall be carried out before use and after use(left unused) to arrive at the net qty of gravel used by the contractor in the work & payment against this item shall only be made for the qty of gravel used in the work not for the total qty of gravel brought. 98 Material and labour for testing and developing the bore well by means of aircompressor5000 PSItill sand free clear water discharge is obtained to achieve maximum yield of suitable capacity for first 24 hours running complete all as specified and directedNote : All equipments shall be arranged by contractor athis own cost. 99 All as per Srl item No. 11.23 here-in-before but beyond 24 Rs. 100 Material and labour for yield testing of the tube well by means of engine driven pumping set of suitable capacity, the discharge shall be measured by providing orifice system or ‘V’ notch fixed to steel tank of adequatecapacity complete all as directed by Engineer-in-Charge. Note : All equipments arranged by contractor at his cost & rates are deemed to be included in quoted rates. 101 Testing portability of water by chemical analysis such as PH Value, dissolved solids, hardness as CaCo3 and Calcium, Magnesium, Chlorides, sulphate, nitrate, alkality, Iron Turbidity NTU, mineral oil, colour hazen units, taste, odour, residual free chlorine, total Coliform per 100mm (microbiological test) and E Coli as per 100ml (microbiological test) as well as bacteriological portability from any Govt lab complete all as directed by Engineer-in-Charge. 102 Supply, installation, commissioningand testing of submersible pump set V-8Multistage (As per mfg design stage ( min 4 stage)) electric driven 2900 RPM of capacity not less than 780 LPM at not less than 90mtr head water lubricated suitable for 200/250mm bore and 150 mm dia discharge pipe coupled with squirrel cage induction electric motor 3 phase 415 volts of capacity not less than 30 HP having CI casing & Gun Metal impeller fitted with delivery pipe etc as reqd at sitewith suitableelectric motor, B class insulation, IP-68 Protection and electric connection With following MOC: Stainless Steel Impeller, Stainless Steel Pump Shaft, LTB Pump Bushes, Cast Iron Bowl/Stage Casing; complete all as directed by Engineer-in-Charge. 103 Supply and fixing Flat Submersible cable PVC multi-stranded copper conductor 3 core 16 sqmm from LT Panel/ star-delta starter to pump motors complete all as directed by Engineer-in-Charge. 104 Supply and fixing mild steel Columnpipe heavy duty5.4 mm wallthickness 100 mm dia in 3 m length includingflanged both side including provision of nuts, bolts, gasket etc including lowering and fixing complete all as directed by Engineer-in-Charge. 105 Supply, installation, testing and commissioning in replacement of CPRI approved, factory made, LT panel board cubical, indoor type, floor mounted double door, suitable for AC, 3 phase 4 wire, 50 cycles, 415 Volts,Front & Rear openable double door with locking arrangement. The panel board shall be made of 2.0 mm thick CRCA/MS sheet (Min size 1.2 m x 1.0 m x 0.45 m) with Synthetic enamel Paint both side.The panel have to provide proper compartment as per IS specification and wiring of panel with suitable size of copper conductor FRLS cable not less than 2.5 Sqmm ,gaskets thimbles including cable entry glands, all as directed. Base frame of the panel shall bemade of angle iron of size 50 x50 x 6mm of upto 1/2 mtr height from GL& 1/2 mtr for Below GL in PCC (1:3:6) type C-2 using 40 mm stone aggregatescomprising of following:-(i) Panel having common aluminium bus bar of capacity 400 Amp TPN each ( Size 40mm x10 mm) and suitable capacity TPN bus bar for outgoing MCCBs, including aluminium lugs to connect the cable and cable gland for Each cable entry as per cable size(ii) INCOMING(a) (a) MCCB Adjustable type thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 200 Amp 4 Pole ICU= 36 KA with overload variation 40-100%- 01 No(iii) OUTGOING(a)MCCB thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 100 Amp 4 Pole ICU = ICS = 16 KA- 01 No.Make : ABB/SIEMENS/SCHNEIDER.(outgoing)(b) MCCB thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 63 Amp 4 Pole ICU = ICS = 16 KA- 01 No.Make : ABB/SIEMENS/SCHNEIDER.(outgoing)(c) MCB TPN 63 Amps -01 Nos(d) ON LOAD Change over switch 200 Amps -01 No(e) Automatic star delta submersible starter DLX (with short circuit protection) HGS series suitable for 30-35 HP motor provided with protection degree IP-54 and FRLS internal wiring and extended wide bend coil and in-built metering and contactor size is MN 50 and Overload relay Range 28 A-40 A and TP MCB rating 100 Amps and Starter should be provided with Single phase preventer etc all as directed.(iv) Volt Meter 0 - 500 Volts digital type square shapeflush mounted with selector switch - 1 No(v) Ammeter 0 - 200 Amps digital type square shape 96mm flush mounted with selector switch and CTs 200/5 A - 1 No.(vi) Indicator lamp RYB : 01 Set, with Suitable CT Coil complete 106 Supply, installation and testing of Heavy duty Chemical Dosing system plunger type suitable to inject solution upto 25 LPH, working pressure 10 kg /cm square comprising dosing pump coupled with three phase electric motor of capacity 0.5 HP,1440 RPM assembled with agitator in one motor , agitator with SS sweep blade duly FRP coated, FRP tank 150 ltrs capacity, complete unit mounted on heavy duty panited with MS fabricated frame duly anticorrosive paint, with Chemical grade PVC NRV including inlet /outlet check valve all connections ,connecting CPVC/UPVC/PVC Fittings ,Pipe etc complete all as required at site and as directed by Engineer-in-Charge. 107 STP WORKS 108 Design, Supply, construction, installation, testing & commissioning of Sewage Treatment Plant 100 KLD based on principle of aerobic attached growth non-clogging randomly Moving Bed Bio-reactor (MBBR) prefab type, including required foundations and & covering of all motors with MS sheets covers & the following :-(a) One no. Fine bar screen chamber fitted with screen of MS epoxy construction as per given minimum specifications, to be installed in Fine Barscreen chambers, provided at an angle of 60° to prevent floating objectspassing through it and subsequently removing manually and dumped forfurther disposal(b) One No. Oil & Grease Removal Chamber in RCC construction with design mix concrete of grade M-30, for removal of free floating Oil & Grease in the sewage, as per given specifications(c) One No. Equalisation tank in RCC construction with design mix concrete of grade M-30, as per given specifications, to cater for the peak discharge including provision of diffused air to ensure that septic conditions do notoccur in tank at all. One lot of air grid for equalization tank for providingaeration in the tank, as specified in PS.(d) Two Nos. raw sewage pumps complete with motor and all necessaryaccessories and fittings, to be installed for transferring sewage fromequalization tank to process reactor. Level sensor should be provided in the tank and interlinked with pumps for ON-OFF operation as per water level in the tank. One pressure gauge for each pump has to be provided to measure pressure at the outlet.(e) Two nos. Air blower complete with motor and all necessary accessorieSupply and fixingittings, for providing air in equalization tank, MBBR reactors & Sludge holding tank. One no. Air rotameter is to be provided in each line to MBBR reactor 1 & 2, & EQT for measurement of quantity of air.(f) One lot of anoxic chamber in MSEP construction with internals comprising of media and MSEP Mixer. 109 (g) Two lot of MBBR Tank in MSEP construction with internals comprising of media, SS air grid & SS rise pipe, media retaining sieves, etc.(h) One Lot of Tube settler tank in MSEP construction with internals comprising of media, supporting structure & collection trough.(j) Two Nos. sewage centrifugal mono-block self-priming recirculation pumps complete with motor and all necessary accessories and fittings. One pressure gauge for each pump is provided to measure pressure at the outlet.(k) One No. Chlorine Contact cum Filter feed tank in in MSEP construction, as per given specifications. With one set of chlorine dosing system comprising of solution tank and dosing pumps, as specified in PS, with necessary connection for dosing of solution in chlorine contact tank.(l) Two Nos. filter feed centrifugal monobloc pumps complete with motor and all necessary accessories and fittings for feeding tertiary unit, Level sensor should be provided in the chlorine contact cum filter feed tank andinterlinked with pumps for ON-OFF operation as per level in the sump. Onepressure gauge for each pump is provided to measure pressure at theoutlet(m) One No. Dual Media filter, complete with media, frontal piping, valve andpressure gauges to measure pressure across the filter.(n) One No. Activated Carbon Filter of, complete with media, frontal piping, valve and pressure gauges to measure pressure across the filter(o) One No. Treated Water tank in MSEP construction, to receive supernatant coming from tertiary treatment plant, as per given specifications(p) Two Nos. sludge transfer self-priming mono-block pumps complete with motor and all necessary accessories and fittings. One pressure gauge for each pump has to be provided to measure pressure at the outlet 110 (q) One No. Continuous feed sludge screw press with dosing system for sludge dewatering system as specified in PS(r) One No. MCC Panel for operation of all electromechanical units of sewage treatment plant(s) One lot of suitable size Piping & valves of suitable material to interconnect various units as per site layout.(t) One lot of Power & control cables to interconnect various drives and instrumentations with STP panel.(u) One lot of foundations in PCC for all E&M equipment, as required.Note :The prices for Design, Supply,construction, installation, testing and commissioning of 100 KLDSTP based on MBBR technologyincluding all civil, electromechanical andinstrumentation works as per thespecifications given in technical specification including requiredfoundations. 111 Supply and fixing of Non Clog Centrifugal sewage pump having 20 mtr Head, Capable of delivering approx. 937.5 LPM at 20 mtr Head with 10 HP AC Electric Motor 3 Phase, 415V, 50C/S, 1450RPM directly coupled on a common base frame complete all as directed by Engineer-in-Charge. Make: Kirloskar/ KSB/ Crompton 112 Supply and fixing cast iron foot valve flanged end conforming to IS 4038 PN 0.2, 100 mm (4”) dia size all as specified and directed 113 Supply, installation, testing and commissioning in replacement of CPRI approved, factory made, LT panel board cubical, indoor type, floor mounted double door, suitable for AC, 3 phase 4 wire, 50 cycles, 415 Volts,Front & Rear openable double door with locking arrangement. The panel board shall be made of 2.0 mm thick CRCA/MS sheet (Min size 1.2 m x 1.0 m x 0.45 m) painted with Synthetic enamel Paint both side.The panel have to provide proper compartment as per IS specification and wiring of panel with suitable size of copper conductor FRLS cable not less than 2.5 Sqmm, gaskets thimbles including cable entry glands, all as directed. Base frame of the panel shall bemade of angle iron of size 50 x50 x 6mm of upto 1/2 mtr height from GL& 1/2 mtr Below GL in PCC (1:3:6) type C-2 using 40 mm graded stone aggregatescomprising of following:-(i) Panel having common aluminium bus bar of capacity 400 Amp TPN each ( Size 40mm x10 mm) and suitable capacity TPN bus bar for outgoing MCCBs, including aluminium lugs to connect the cable and cable gland for Each cable entry as per cable size(ii) INCOMING(a) MCCB Adjustable type thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 100 Amp 4 Pole ICU= 16 KA with overload variation 40-100%- 01 No(iii) OUTGOING(a)MCCB thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 63 Amp 4 Pole ICU = ICS = 16 KA- 02 Nos (c) MCB SPN 32 Amps -01 No(d) ON LOAD Change over switch 100 Amps -01 No(e) Automatic star delta submersible starter ASD (with short circuit protection) HSG series suitable for 10-12.5 HPmotor provided with protection degree IP-54 and FRLS internal wiring and extended wide bend coil and in-built metering and contactor size 18 and Overload relay Range 8 A-12 A and class H Insulation and Starter should be provided with Single phase preventer etc all as directed.(iv) Volt Meter 0 - 500 Volts digital type square shapeflush mounted with selector switch - 1 No(v) Ammeter 0 - 200 Amps digital type square shape 96mm flush mounted with selector switch and CTs 200/5 A - 1 No.(vi) Indicator lamp RYB :01 Set. with Suitable CT Coil complete 114 Outsourcing of Manning / Operation & routine periodical maintenance of electro -Mechanical equipment’s, control valves, instrumentals etc of STP 100 Cum/day (for Two shifts per day including Sunday & holiday, by employing One FGM (Semi skilled operator) and One helper per Shift (each shift of eight hours) and maintaining desired level of BOD/COD, TSS, TKN by dosing of required quantity of chemicals as per OEM recommendation complete for a period of 11 months starting from the next day of certified date of completion of Phase-I (to be intimated by GE through Work Order separately) complete all as specified and directed.Note :- (a) Maintenance of log sheet and all maintenance records shall be responsibility of the contractor and no stationary shall be provided by the Department. Format of log sheet and records etc shall be decided by GE/ Engineer -in-charge(b) The contractor is responsible to maintain the installations and surrounding area in presentable manner through out the period. The shift timings shall be decided by Engineer- in- charge and liable to change as and when required by Engineer- incharge.(c) Area cleaning surrounding the plant room & inside the plant room etc shall be responsibility of the contractor (d)The contractor shall be maintain clear record of attendance for workmen/ staff. (e) Consumables i.e grease, lubricant oil, cotton waste washers etc required for routine maintenance of STP shall be provided by contractor and cost of the same shall be deemed to be included in unit rates quoted.(f) Cost of stationary required for attendance register, meter readings, site order books, log sheets etc shall be provided by contractor and cost of same shall be deemed to be included in unit rates quoted by contractor.(g) FGM/ Operator should be ITI qualified in respective trade i.e. electrical/ fitter and having minimum 2 years experience in similar trade/ works.(h) Helper should be having 2 years experience in similar trade(j) Timing of shift shall be as decided by Engineer-in-Charge and as specified . 115 TREATED SEWAGE WATER SUPPLY WORKS 116 Supply and fixing 3 phase horizontal, radially split volute casing centrifugal pump 3 HP in back pull out design, single stage, single entry with radial impeller equipped with VFD devices & equipped with speed control panel to control speed/ discharge pump set capacity of discharge 500 LPM at delivery head of 22mtr of IE 3* & with MOC material CI/ bronze with suitable electrical panel, cable & starter complete all as directed by Engineer-in-Charge. 117 Supply and fixing motor starter for 3 HP pumping sets, centrifugal, electric driven having extended wide bend, coil, FRLS internal wiring, providing with protection degree IP 54, starter type air break, class H insulation complete all as directed by Engineer-in-Charge. 118 Supply and fixing PPR gate valves (brass insert) of 160mm bore complete all as specified and directed 119 Supply and fixing PPR gate valves (brass insert) of 75mm bore complete all as specified and directed 120 Supply and fixing cast iron air valve with single air outlets, conforming to IS : 14845 of size 50mm bore and fixing up in cast iron water supply mains of size 100mm bore complete all as specified and directed 121 Supply and fixing cast iron air valve with single air outlets, conforming to IS : 14845 of size 50mm dia and fixing up in cast iron water supply mains of size 150mm dia complete all as specified and directed

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 30-Jan-2023 CORRIGENDUM NO 01 DATED 30 JAN 2023 Date 13-02-2023
2 01-Feb-2023 CORRIGENDUM NO 02 DATED 01 FEB 2023 Other 13-02-2023

Key Value

Document Fees
INR 3000 /-
EMD
INR 1500000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Provn of PH-I of OTM accn for Mech Inf Bn at Ferozepur under GE (East) Ferozepur Cantt (Tender ID : 2022_MES_545540_2)
Sl. No. Item Description
1Note: (i) Please refer Schedule "A" Notes given on serial page No. 21 to 27 of tender documents.
2LUMPSUM/ OTHER PRE-PRICED PROVISIONAL SCHEDULES OF WORKS
3Lump sum price worked out by the contractor for BUILDING WORKS as listed in Schedule "A" Part-I brought forward from serial page No. 29.
4Lump sum price worked out by the contractor for SITE CLEARANCE AND EARTHWORKS as listed in Schedule "A" Part-II brought forward from serial page No. 30.
5Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION WORKS as listed in Schedule "A" Part-III brought forward from serial page No. 37.
6Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY WORKS as listed in Schedule "A" Part-IV brought forward from serial page No. 38.
7Lump sum price worked out by the contractor for SEWAGE DISPOSAL WORKS as listed in Schedule "A" Part-V brought forward from serial page No. 40.
8Lump sum price worked out by the contractor for ROAD, PATHAND CULVERTS WORKS as listed in Schedule "A" Part-VI brought forward from serial page No. 42.
9Lump sum price worked out by the contractor for AREA DRAINAGE WORKS listed in Schedule "A" Part-VII brought forward from serial page No. 43.
10Lump sum price worked out by the contractor for BOUNDARY WALL, COMPOUND WALL,FENCING AND GATE WORKS listed in Schedule "A" Part-VIII brought forward from serial page No. 45.
11Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLYWORKS as listed in Schedule "A" Part-IX brought forward from serial page No. 46.
12Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATIONWORKS as listed in Schedule "A" Part-X brought forward from serial page No. 50.
13Lump sum price worked out by the contractor for DG SET WORKS as listed in Schedule "A" Part-XI brought forward from serial page No. 51.
14Lump sum price worked out by the contractor for SUMMER APPLIANCES WORKSas listed in Schedule "A" Part-XII brought forward from serial page No. 53.
15Lump sum price worked out by the contractor for RAIN WATER HARVESTING WORKSas listed in Schedule "A" Part-XIII brought forward from serial page No. 54.
16Lump sum price worked out by the contractor for HOT WATER SUPPLY WORKS as listed in Schedule "A" Part-XIV brought forward from serial page No. 56.
17Lump sum price worked out by the contractor forLIGHTENING CONDUCTOR WORKS as listed in Schedule "A" Part-XV brought forward from serial page No. 57.
18Lump sum price worked out by the contractor for BORE WELL WORKS as listed in Schedule "A" Part-XVI brought forward from serial page No. 58.
19Lump sum price worked out by the contractor for STP WORKS as listed in Schedule "A" Part-XVII brought forward from serial page No. 59.
20Lump sum price worked out by the contractor for TREATED SEWAGE WATER SUPPLY WORKS as listed in Schedule "A" Part-XVIII brought forward from serial page No. 60.
21Lump sum price worked out by the contractor for PCC HARD STANDING WORKS as listed in Schedule "A" Part-XIX brought forward from serial page No. 61.
22SCHEDULE "A" PART-XX MISC ITEMS INTERNAL ELECTRIFICATION WORKS
23Supply and Fix energy efficient LED bulb, B229 Watt complete all as specified and directed. Make:- Cat No LHLDBWEB4L8R009 of Havells or eqvt in Philips and CG.
24Supply and Fix Modular RJ telephone socketcomplete all as specified and directed by Engr -in- Charge. Make:- Cat No / SAP code AHLKHWW000 of Havells or eqvt in Legrand/ Schneider.
25Supply and Fix Modular TV Socket complete all as specified and directed by Engr -in- Charge.Cat No /SAP code AHLKT0W000 of Havells or eqvt in Legrand/ Schneider.
26Supply and FixDecorative 9W LEDwall mounting fittings complete set including 9 W LED lamp all as specified and directed. Make:- Cat No LHF0ECEITZIB014 Glaze Wall Light of Havellsor eqvt in Philips / Crompton.
27S&F GI pipe bracket made out of GI pipe light grade 32 mm dia and bend to shape 1.5 mtr long MS clamps made out of MS flat iron of size 25x4 mm thick with nuts & bolts, washers complete as specified and directed
28Supply and fix wall mounting fan industrial type 450mm sweep, 230V, 50Hz , 1400 RPM, 100W, 150cum/hr air delivery, copper motor, double ball bearing , 60dB - 65dB nosie level, upward and down adjustable, 60 degree oscillation degree, 3 Nos metal balde guarded with 112 spokes metal case complete with mountings accessories kit, wall bracket, nut, bolt washer etc with connection PVC three core copper wire all as specified and directed. Make:- Cat No FHACWSTSCL18 of Havells or eqvt in Legrand/ Philips.
29SEWAGE DISPOSAL WORKS
30Material and labour for laying DWC HDPE 150mm (I/D) SN8 pipe including all necessary fittings for carrying sewage complete all as directed by Engineer in Charge.
31Material and labour for laying DWC HDPE 200mm (I/D) SN8 pipe including all necessary fittings for carrying sewage complete all as directed by Engineer in Charge.
32Material and labour for construction of under gournd sump cum pump house complete all as shown on drawings and as specified. (Drg No CEJZ-04/2000 Sheet No. 1/2 to 2/2).
33ROAD, PATHAND CULVERTS WORKS
34Material and labour for cat eye abs plastic with nail of size 100mm x 100mm, 20mm reflective glass colour White/ Red/ Yellow provided with steel zinc plated with bolt of 12mm dia length 120mm for fixing on road by hammering complete all as directed by Engineer in Charge.
35Material and labour for delineator 47mm dia 600mm long with high intensity reflective sheeting complete all as directed by Engineer-in-Charge.
36EXTERNAL WATER SUPPLY WORKS
37Supplying, laying, jointing and testing in trenches centrifugally cast 150mm bore ductile iron pipe class K-7 conforming to IS : 8329-2000 of min wall thickness 5.4mm including testing complete all as specified.
38Supplying, laying, jointing and testing in trenches centrifugally cast 100mm bore ductile iron pipe class K-7 conforming to IS : 8329-2000 of min wall thickness 5.4mm including testing complete all as specified Notes for Srl No. 6.01 & 6.02 :- (a) Excavation, earth work and DI fittings shall be measured and paid for separately under respective items (b) Cost of tyton joints is included in the rate quoted. (c) Standard length of the pipe should be 5.50m or 6.0m as available. (d) The measurement of the pipe shall be net as fixed between the fittings including short length without any allowance for cutting and wastage and for the portion entering in the socket of all pipes and fittings. (e) Predespatch inspection & testing of DI pipe shall be carried out by the representative of AO. All the expenditure for the same shall be borne by the contractor and the quoted rates shall be deemed to be included for the same
39Supply, fixing and testing ductile iron fittings such as bends (any type radius and angle) tapers any type (straight, bend, increasing, decreasing or double socket etc) tee pieces single branch ‘Y’ junction. Double branch, cross (all sockets or sockets and spigot) collars, tail pieces with one end flanged (integrally cast) and one end socket. Spigot caps and plugs suitable for 100 to 150mm ductile iron pressure pipes of K-7 classification and push on flexible rubber gasket joints complete all as specified and directed Notes : (a) DI fittings shall be of same make as of DI pipes or of make as recommended by manufacturers (b) The weight of the fittings shall be measured and paid as given in relevant IS or actually provided whichever is less. (c) All fittings shall be relevant IS stamping marking. (d) Excavation and earth work shall be measured and paid for separately. (e) Cost of the joints and jointing materials shall be deemed to be included in the relevant items of DI pipes here-in-before
40Construction of brick masonary valve pit chamber of 1050mm x 750mm x 1000mm size (internal dimensions) with MS sheet cover 6mm thick and angle iron 40mm x 40mm x 6mm frame duly painted with two coat of synthetic enamel paint over one coat of red oxide primer including locking arrangement, necessary earth work etc complete all as specified and shown on drgs. Breakdown of Qty External Water Supply-4 (Each) Treated Sewage Water Supply-2 (Each)
41Construction of brick masonary valve pit chamber of 900 x 900 x 1000mm size (internal dimensions) with MS sheet cover 6mm thick and angle iron 40 x 40 x 6mm frame duly painted with two coat of synthetic enamel paint over one coat of red oxide primer including locking arrangement, necessary earth work etc complete all as specified andshown on drgs. Breakdown of Qty External Water Supply-5 (Each) Treated Sewage Water Supply-3 (Each)
42Construction of brick masonary valve pit chamber of 600mm x 600mm x 1000mm size (internal dimensions) with MS sheet cover 6mm thick and angle iron 40mm x 40mm x 6mm frame duly painted with two coat of synthetic enamel paint over one coat of red oxide primer including locking arrangement, necessary earth work etc complete all as specified andshown on drgs. Note for Srl item No. 6.04 to 6.06:-
43Supply and fixing RCC water main route indicator of size 75cm x 40cm x 10cm duly marked with MES Water Mains Bore made of cement concrete (1:2:4) type B-1 as in foundation of electric poles/ struts etc including necessary form work, fair, finished embedded in PCC bed including necessary excavation and re-filling, proposed to be installed after 25m on pipe lines of size 150mm, 100mm, 80mm and 50mm complete all as directed by Engineer-in-Charge.
44EXTERNAL ELECTRIC SUPPLY WORKS
45Supply ,install, testing and commissioning power factor control LT panel board (APFC) of 200 KVAR, 433 volt, 50 Cycle per second cubical type front and back openable double leaf type dust & vermin proof with locking arrangement powder coated with approved colour , made out of CRCA sheet 14 SWG, outdoor herewith canopy, cable entry glands, double compressor type, duly prewired with suitable pillar made out of 50 mmx 50mm x6 mm angle iron grouted in and including PCC (1:2:4) using 20 mm graded stone aggregate complete all as per IS 8623-1933 & all as per latest ISI specification and suitable for housing and including following accessories :- (a) Incoming MCCB of 250 Amps 36 KA rupturing capacity , 3 Pole thermal magnetic release type shunt trip coil -01 No (b) Copper Bus bar duly insulated with colour coded heat shrinkable sleeve insulation for three phase four wire system of 250 Amps capacity rating with suitable size/ type on hygroscopic on combustion track resistance, high strength FRP/MC/DMC insulators. (c) Capacitor switching contactor of suitable capacity (contractor amps rating shell not be less than 1.5 times nominal current rating, three pole, coil voltage 440 Volts, one each for number of capacitor bank , each contractor shell be protected with 10 KA , d curve type (MCB to be provided for 1.33 times KVAR i.e. 100 % current capacity of the MPFCS irrespective of the fact that contractor’s rating is 1.5 times) (MCCB 25 KA shall be provided for the above 63 Amps rating) (d) One set current transformer (CTs) of suitable ratio (with secondary of 5 Amps ) to be fixed on bus bar of existing panel including connection with 2 core 1.5 Sqmm armoured copper conductor complete with gland etc. (e) Shunt capacitor MPP type heavy duty 200 KVAR distributed in step of 6 steps with configuration (2x12.5 + 1x25 + 3x50) directly connected to maintain power factor at 0.99 or unity, housed in self-extinguishing insulated material with built in.
46Supply and fixing 3 core 1.5 sqmm PVC insulated and FRLS PVC round sheathed copper conductor flexible 1100 volts for connection from Junction Box to street light fittings complete all as specified and directed. Make :Polycab/ Havells/ Finolex/ Paragon
47Supply and fixing street light pole cable junction box IP-65 with metric knockouts for cable entry with MCB SP 6 Amps,10 KA and the box made out of thermal plastic material suitable for 16/25 Sqmm UG cable including clamps bolts, nuts, duly painted etc complete all as and directed by Engineer-in-Charge.
48Supply and fixing bracket made out of 40 mm dia GI light grade tubing 1.2 meter long and bent to angle /shape of 120 degree angle at the meddle from vertical fixed with clamps nuts and bolts washers complete all as specified and directed
49Supply and fixing automatic street light switchfor automatic switching of street light/high mast light (timer switch)for Three Phase Loadlight.The Digital timer 24 hrs alongwith suitable power contractor as per IEC - 60947-4-1, including incoming & outgoing MCBs, SMC Enclosure and support terminal and enclosed in pole/wall mounted factory made PVC enclosure made out of rust proof, shock & termite proof and FRLS grade confirming to IP-54 of capacity 6 KW, Three phase, Current rating 32/TP and MCB rating 40/TPN, having facility of manual operation complete all as directed by Engineer-in-Charge.
50Supply, installation, testing and commissioning of CPRI approved, factory made, LT panel board cubical, Outdoor type, floor mounted double door, Front & Rear openable with locking arrangement, suitable for AC,3 phase, 4 wire, 50 cycles, 415 Volts. The panel board shall be made of 3.15 thick CRCA/MS sheet (Min size 1.8 m x 1.5 m x 1.0 m) painted with Synthetic enamel Paint both side. The panel have to provide proper compartment as per IS specification and wiring of panel with suitable size of copper conductor FRLS cable not less than 2.5 Sqmm with thimbles all as directed. Base frame of the panel shall bemade of angle iron of size 50 x50 x 6mm of upto 1/2 mtr height from GL & 1/2 mtr below GL in PCC (1:3:6) type C-2 using 40 mm graded stone aggregates comprising of following:- Location - Main Panel (X-Mer - 400 KVA) (i) Panel having common aluminium bus bar of capacity 1600 Amp TPN each and suitable capacity TPN bus bar for outgoing MCCB"s, including aluminium lugs to connect the cable and cable gland for Each cable entry as per cable size. (ii) INCOMING (a)ACB Microprocessor released and thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 800 Amp 4 Pole, 50 KAwith overload variation 40-100%- 1 No, (iii) OUTGOING (a)MCCB thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 250 Amp 3 Pole, 35 KA with overload variation 40-100%- 1 No,(for APFC ) (b)-do- but 250 Amp - 1 No, (c)-do- but 160 Amp - 1 No, (d)-do- but 125 Amp - 02 Nos, (e)-do- but 63 Amp - 6 Nos, (iv)Volt Meter 0 - 500 Volts digital type square shapeflush mounted with selector switch - 1 No. (v)Ammeter 0 - 800 Amps digital type square shape 96mm flush mounted with selector switch and CT"s 800/5 A - 1 No. (vi) Phase indicating lamp "LED TYPE" 03 Nos
51Supply, installation, testing and commissioning of CPRI approved, factory made, LT panel board cubical, Outdoor type, floor mounted double door, Front & Rear openable with locking arrangement, suitable for AC,3 phase, 4 wire, 50 cycles, 415 Volts. The panel board shall be made of 3.15 thick CRCA/MS sheet (Min size 1.6 m x 1.35 m x 0.8 m) painted with synthetic enamel paint both side. The panel have to provide proper compartment as per IS specification and wiring of panel with suitable size of copper conductor FRLS cable not less than 2.5 Sqmm with thimbles all as directed. Base frame of the panel shall bemade of angle iron of size 50 x50 x 6mm of upto 1/2 mtr height from GL & 1/2 mtr below GL in PCC (1:3:6) type C-2 using 40 mm graded stone aggregates comprising of following:- Location - Near SMBK (i) Panel having common aluminium bus bar of capacity 500 Amp TPN each and suitable capacity TPN bus bar for outgoing MCCB"s, including aluminium lugs to connect the cable and cable gland for Each cable entry as per cable size. (ii) INCOMING (a)MCCB thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 250 Amp 4 Pole, 35 KAwith overload variation 40-100%- 1 No. (iii) OUTGOING (a)MCCB thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 63 Amp 4 Pole, 16 KA with overload variation 40-100%- 4 Nos. (b)-do- but 32 Amp - 2 Nos, (iv)Volt Meter 0 - 500 Volts digital type square shapeflush mounted with selector switch - 1 No. (v)Ammeter 0 - 250 Amps digital type square shape 96mm flush mounted with selector switch and CT"s 250/5 A - 1 No. (vi) Phase indicating lamp "LED TYPE" 03 Nos
52Supply, installation, testing and commissioning of CPRI approved, factory made, LT panel board cubical, Outdoor type, floor mounted double door, Front & Rear openable with locking arrangement, suitable for AC, 3 phase, 4 wire, 50 cycles, 415 Volts. The panel board shall be made of 3.15 thick CRCA/MS sheet (Min size 1.6 m x 1.35 m x 0.8 m) painted with synthetic enamel paint both side. The panel have to provide proper compartment as per IS specification and wiring of panel with suitable size of copper conductor FRLS cable not less than 2.5 Sqmm with thimbles all as directed. Base frame of the panel shall bemade of angle iron of size 50 x50 x 6mm of upto 1/2 mtr height from GL & 1/2 mtrbelow GL in PCC (1:3:6) type C-2 using 40 mm graded stone aggregates comprising of following:- Location - Near JCO MESS (i) Panel having common aluminium bus bar of capacity 320 Amp TPN each and suitable capacity TPN bus bar for outgoing MCCB"s, including aluminium lugs to connect the cable and cable gland for Each cable entry as per cable size. (ii) INCOMING (a)MCCB thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 160 Amp 4 Pole, ICU=ICS=35 KAwith overload variation 40-100%- 1 No. (iii) OUTGOING (a) MCCB thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 80 Amp 4 Pole, ICU=ICS=25 KA with overload variation 40-100%-1 No. (b)MCCB thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 32 Amp 4 Pole, ICU=ICS=16 KA with overload variation 40-100%- 4 Nos. (c)MCB isolator 25 Amp SPN 10 KA, 240V-01 No, (iv)Volt Meter 0 - 500 Volts digital type square shapeflush mounted with selector switch - 1 No. (v)Ammeter 0 - 160 Amps digital type square shape 96mm flush mounted with selector switch and CT"s 160/5 A - 1 No. (vi) Phase indicating lamp "LED TYPE" 03 Nos
53Supply, installation, testing and commissioning of CPRI approved, factory made, LT panel board cubical, Outdoor type, floor mounted double door, Front & Rear openable with locking arrangement, suitable for AC, 3 phase, 4 wire, 50 cycles, 415 Volts. The panel board shall be made of 3.15 thick CRCA/MS sheet (Min size 1.6 m x 1.35 m x 0.8 m) painted with synthetic enamel paint both side. The panel have to provide proper compartment as per IS specification and wiring of panel with suitable size of copper conductor FRLS cable not less than 2.5 Sqmm with thimbles all as directed. Base frame of the panel shall bemade of angle iron of size 50 x50 x 6mm of upto 1/2 mtr height from GL & 1/2 mtr below GL in PCC (1:3:6) type C-2 using 40 mm graded stone aggregates comprising of following:- Location - Near Offr MESS (i) Panel having common aluminium bus bar of capacity 250 Amp TPN each and suitable capacity TPN bus bar for outgoing MCCB"s, including aluminium lugs to connect the cable and cable gland for Each cable entry as per cable size. (ii) INCOMING (a)MCCB thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 125 Amp 4 Pole, ICU=ICS=25 KAwith overload variation 40-100%- 1 No. (iii) OUTGOING (a)MCCB thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 63 Amp 4 Pole, ICU=ICS=16 KA with overload variation 40-100%- 2 Nos. (b)MCCB thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 32 Amp 4 Pole, ICU=ICS=25 KA with overload variation 40-100%- 2 Nos. (c)MCB isolator 32 Amp SPN 10 KA, 240V-04 Nos, (iv)Volt Meter 0 - 500 Volts digital type square shapeflush mounted with selector switch - 1 No. (v)Ammeter 0 - 125 Amps digital type square shape 96mm flush mounted with selector switch and CT"s 125/5 A - 1 No. (vi) Phase indicating lamp "LED TYPE" 03 Nos
54Supply, installation, testing and commissioning of CPRI approved, factory made, LT panel board cubical, Outdoor type, floor mounted double door, Front & Rear openable with locking arrangement, suitable for AC, 3 phase, 4 wire, 50 cycles, 415 Volts. The panel board shall be made of 3.15 thick CRCA/MS sheet (Min size 1.6 m x 1.35 m x 0.8 m) painted with synthetic enamel paint both side. The panel have to provide proper compartment as per IS specification and wiring of panel with suitable size of copper conductor FRLS cable not less than 2.5 Sqmm with thimbles all as directed. Base frame of the panel shall bemade of angle iron of size 50 x50 x 6mm of upto 1/2 mtr height from GL & 1/2 mtr below GL in PCC (1:3:6) type C-2 using 40 mm graded stone aggregates comprising of following:- Location - Near Adm Block (i) Panel having common aluminium bus bar of capacity 250 Amp TPN each and suitable capacity TPN bus bar for outgoing MCCB"s, including aluminium lugs to connect the cable and cable gland for Each cable entry as per cable size. (ii) INCOMING (a)MCCB thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 125 Amp 4 Pole, ICU=ICS=25 KAwith overload variation 40-100%- 1 No. (iii) OUTGOING (a)MCCB thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 63 Amp 4 Pole, ICU=ICS=16 KA with overload variation 40-100%- 2 Nos. (b)MCCB thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 32 Amp 4 Pole, ICU=ICS=25 KA with overload variation 40-100%- 2 Nos. (iv)Volt Meter 0 - 500 Volts digital type square shapeflush mounted with selector switch - 1 No. (v)Ammeter 0 - 125 Amps digital type square shape 96mm flush mounted with selector switch and CT"s 125/5 A - 1 No. (vi) Phase indicating lamp "LED TYPE" 03 Nos
55Supply, installation, testing and commissioning of CPRI approved, factory made, LT panel board cubical, Outdoor type, floor mounted double door, Front & Rear openable with locking arrangement, suitable for AC, 3 phase, 4 wire, 50 cycles, 415 Volts. The panel board shall be made of 3.15 thick CRCA/MS sheet (Min size 1.6 m x 1.35 m x 0.8 m) painted with synthetic enamel paint both side. The panel have to provide proper compartment as per IS specification and wiring of panel with suitable size of copper conductor FRLS cable not less than 2.5 Sqmm with thimbles all as directed. Base frame of the panel shall bemade of angle iron of size 50 x50 x 6mm of upto 1/2 mtr height from GL & 1/2 mtr below GL in PCC (1:3:6) type C-2 using 40 mm graded stone aggregates comprising of following:- Location - MT area panel (i) Panel having common aluminium bus bar of capacity 200 Amp TPN each and suitable capacity TPN bus bar for outgoing MCCB"s, including aluminium lugs to connect the cable and cable gland for Each cable entry as per cable size. (ii) INCOMING (a)MCCB thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 63 Amp 4 Pole, ICU=ICS=16 KAwith overload variation 40-100%- 1 No. (iii) OUTGOING (a)MCCB thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 32 Amp 4 Pole, ICU=ICS=16 KA with overload variation 40-100%- 4 Nos. (b)MCB isolator 25 Amp SPN 10 KA, 240V-10 Nos. (iv)Volt Meter 0 - 500 Volts digital type square shapeflush mounted with selector switch - 1 No. (v)Ammeter 0 - 100 Amps digital type square shape 96mm flush mounted with selector switch and CT"s 100/5 A - 1 No. (vi) Phase indicating lamp "LED TYPE" 03 Nos
56Supply, installation, testing and commissioning of CPRI approved, factory made, LT panel board cubical, Outdoor type, floor mounted double door, Front & Rear openable with locking arrangement, suitable for AC, 3 phase, 4 wire, 50 cycles, 415 Volts. The panel board shall be made of 3.15 thick CRCA/MS sheet (Min size 1.4 m x 1.25 m x 0.8 m) painted with synthetic enamel paint both side. The panel have to provide proper compartment as per IS specification and wiring of panel with suitable size of copper conductor FRLS cable not less than 2.5 Sqmm with thimbles all as directed. Base frame of the panel shall bemade of angle iron of size 50 x50 x 6mm of upto 1/2 mtr height from GL & 1/2 mtr below GL in PCC (1:3:6) type C-2 using 40 mm graded stone aggregates comprising of following:- Location - Street light panel (i) Panel having common aluminium bus bar of capacity 200 Amp TPN each and suitable capacity TPN bus bar for outgoing MCCB"s, including aluminium lugs to connect the cable and cable gland for Each cable entry as per cable size. (ii) INCOMING (a)MCCB thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 63 Amp 4 Pole, ICU=ICS=16 KAwith overload variation 40-100%- 1 No. (iii) OUTGOING (a)MCCB thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 32 Amp 4 Pole, ICU=ICS=16 KA with overload variation 40-100%- 3 Nos. (b)ON LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 63 Amp. (iv)Volt Meter 0 - 500 Volts digital type square shapeflush mounted with selector switch - 1 No. (v)Ammeter 0 - 100 Amps digital type square shape 96mm flush mounted with selector switch and CT"s 100/5 A - 1 No. (vi) Phase indicating lamp "LED TYPE" 03 Nos Note Srl item No. 7.06 to 7.12:- LT Panel shall be got tesed from CPRI type test for 4000 Amp with breaking capacity not less than 65 KA and IP 56 as per IS 61439 Part- 1& 2.
57Supply and fixing of rubber mat (Insulation mat) of dimension 1m x 2m and 2 mm thick complete for electrical installation and DG sets panels complete all as directed by Engineer-in-Charge.
58Supply and fixing of rubber mat of dimension 1m x 2m and 3 mm thick complete for electrical installation and STP main panels complete all as specified and directed.
59Supply and fixing RCC HT cable route indicator of size 75cmx40cmx10cm duly marked with HT cable made ofcement concreted (1:2:4) type B-1 as in foundation of electric poles/struts/ etc including necessary form work, fair finished embedded in PCC bed including necessary excavation and re-filling complete all as specified and directed
60DG SET WORKS
61Supply, installing, commissioning and testing of eco-friendly Diesel Engine driven generating set silent type confirming to CPCB conditions/ norms, 62.5 KVA, or next higher capacity as available/manufactured at 0.9 power factor directly coupled alternator & engine. The diesel set shall consist of a diesel engine coupled directly to a matching parts or as recommended/ provided by the manufacturer on a common base frame and thereafter installed in the CPCB approved acoustic enclosure. The complete set conforming to and test certificate as per CPCB norms and as specified) complete without AMF control panel standardized by manufacturer, fuel tank with mounting arrangement, flexible exhaust pipe complete with the following:- (a) Engine (Prime mover) : Diesel engine 1500 RPM of minimum 84 BHP or recommended by manufacturer turbo charged water cooled,12 volts electric battery start, complete with fly wheel and all standard fitting/ fixtures as per manufacturing practice including suitable engine control panel/ dash board with electronic technometer. lube oil temp and pressure gauges water temp gauge frequency meter (digital type) including safety self-starter, alternator, cogged V belt, fuel tank with first fill of lube oil and coolant (as applicable) etc. (b) Alternator :Alternator AC 3 phase 415 Volts 4 wire rated line current for output 62.5 KVA, PF 0.8, 1500 RPM insulation class enclosures /SPDP self-exited self-regulated brushes, complete with AVR with plus and minus voltage regulation directly coupled to and match the above engine. (c) Anti vibration pads for mounting engine, alternator assembly on base frame/plate or as recommended by the manufacturer. (d) Base plate made out of structural steel as per manufacturer recommended design/specification. (e) Acoustic enclosure of an internal type approved/certified acoustic enclosure (as per CPCB norms for the DG Set) to restrict the noise level to 75 db at one meter distance and temp rise with in canopy shall not exceed 7 degree centigradebeyond ambient temp. It shall be made of 16" SWG or manufacturer standard norms CRCA sheet with powder coated finish on outside and provided with non ignitic fire retardant foam as acoustic material. The doors and glass windows shall be ISMC. It shall also include the following:- (i) Silencer/Absorption the non-resistance, residential and exhaust pipe covered with asbestos rope. (ii) Internal wiring with PVC copper conductor cable IS-694 marked FRLS in conduit and fluorescent lamp fittings. (iii) Fuel tank of 16 hours cap but not less than made of 14 SWG CRCA sheet duly powder coated and provided with float gauge and fuel float switch. (iv) One No 12 V X 180 AH 25 plates maintenance free batteries as recommended by manufacturer. (f) The exhaust of DG set shall be fitted with emission control devises as per latest CPCB norms and as specified and also contractor shall submit test certificate of DG set as per latest CPCB norms.
62Supply, installing, commissioning and testing of eco-friendly Diesel Engine driven generating set silent type confirming to CPCB conditions/ norms, 40 KVA, or next higher capacity as available/manufactured at 0.9 power factor directly coupled alternator & engine. The diesel set shall consist of a diesel engine coupled directly to a matching parts or as recommended/ provided by the manufacturer on a common base frame and thereafter installed in the CPCB approved acoustic enclosure. The complete set conforming to and test certificate as per CPCB norms and as specified) complete without AMF control panel standardized by manufacturer, fuel tank with mounting arrangement, flexible exhaust pipe complete with the following:- (a) Engine (Prime mover) : Diesel engine 1500 RPM of minimum 51 BHP or recommended by manufacturer turbo charged water cooled,12 volts electric battery start, complete with fly wheel and all standard fitting/ fixtures as per manufacturing practice including suitable engine control panel/ dash board with electronic technometer. lube oil temp and pressure gauges water temp gauge frequency meter (digital type) including safety self-starter, alternator, cogged V belt, fuel tank with first fill of lube oil and coolant (as applicable) etc. (b) Alternator :Alternator AC 3 phase 415 Volts 4 wire rated line current for output 40 KVA, PF 0.8, 1500 RPM insulation class enclosures /SPDP self-exited self-regulated brushes, complete with AVR with plus and minus voltage regulation directly coupled to and match the above engine. (c) Anti vibration pads for mounting engine, alternator assembly on base frame/plate or as recommended by the manufacturer. (d) Base plate made out of structural steel as per manufacturer recommended design/specification. (e) Acoustic enclosure of an internal type approved/certified acoustic enclosure (as per CPCB norms for the DG Set) to restrict the noise level to 75 db at one meter distance and temp rise with in canopy shall not exceed 7 degree centigradebeyond ambient temp. It shall be made of 16" SWG or manufacturer standard norms CRCA sheet with powder coated finish on outside and provided with non ignitic fire retardant foam as acoustic material. The doors and glass windows shall be ISMC. It shall also include the following:- (i) Silencer/Absorption the non-resistance, residential and exhaust pipe covered with asbestos rope. (ii) Internal wiring with PVC copper conductor cable IS-694 marked FRLS in conduit and fluorescent lamp fittings. (iii) Fuel tank of 16 hours cap but not less than made of 14 SWG CRCA sheet duly powder coated and provided with float gauge and fuel float switch. (iv) One No 12 V X 88 AH 25 plates maintenance free batteries as recommended by manufacturer. (f) The exhaust of DG set shall be fitted with emission control devises as per latest CPCB norms and as specified and also contractor shall submit test certificate of DG set as per latest CPCB norms.
63SUMMER APPLIANCES WORKS
64Supply and fixing voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170V-250V with output voltage stabilized at 230V with accuracy of ±2.5% and of capacity 1.0 KVA complete all as directed by Engineer-in-Charge.
65Supply and fixing voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170V-250V with output voltage stabilized at 230V with accuracy of ±2.5% and of capacity 2.0 KVA complete all as directed by Engineer-in-Charge.
66Supply and fixing voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170V-250V with output voltage stabilized at 230V with accuracy of ±2.5% and of capacity 3.0 KVA complete all as directed by Engineer-in-Charge.
67Supply and fixing voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170-250V with output voltage stabilized at 230V with accuracy of ±2.5% and of capacity 5.0 KVA complete all as directed by Engineer-in-Charge.
68Supply and installed refrigerators, electric driven (single phase) of capacity 220 Ltrs frost free, 5 star rated complete all as directed by Engineer-in-Charge.
69Supply and installed refrigerators, electric driven (single phase) of capacity 400 Ltrs frost free, 5 star rated complete all as directed by Engineer-in-Charge.
70Supply and installing desert cooler electric driven (single phase) having nominal air flow capacity of 4000 Cum/ Hrs 230V made of 20 gauge MS sheet and size not less than 90cm, 78cm x 78cm surface area from top and bottom 62cm x 54cm front grill size including tullu pump with rotary switch (4 speed) 5 Amp switch on front side, drain valve including two coats synthetic of enamel paint over a coat of primer complete all as directed by Engineer in Charge.
71RAIN WATER HARVESTING WORKS
72Material and labour for gravel packing including jute as filter media 4mm to 6mm size around MS pipe complete all as directed by Engineer-in-Charge.
73Material and labour for filling of gravel in trenches of size 6mm to 10mm upto height of 0.50m complete all as directed by Engineer-in-Charge.
74Material and labour for filling of gravel in trenches of size 2mm to 4mm upto height of 1.0m complete all as directed by Engineer-in-Charge.
75BORE WELL WORKS
76Material and labour for Drilling of 675mm bore hole from ground level to 20 m depth below ground levelin any strata by mechanical percussion method below ground level including electrical logging through any kind of strata soils/rocks, disposal of surplus soil keeping space for pea gravel packing and including lowering and extraction of casing pipes complete all as specified and as directed :- Notes : (a) Record shall be maintained for regular sample of cutting after every 3 metre interval to be collected and kept at site (b) The bore/tube well should be constructed by the agency as approved by GE (East) Fzr. (c) The Rates also includes transportation of Rig Machine & T&P at Site. (d) Trail Bore will be drilled, if sufficient wet strata is available then ERW casing will be lowered. In case Strata is not available payment only for drilling will be made
77All as per Srl item No. 11.01 here-in-before but from 20 m below ground level to 40 m depth below ground level.
78All as per Srl item No. 11.01 here-in-before but from 40 m below ground level to 60 m depth below ground level.
79Material and labour for Drilling of 525 mm bore hole from 60 mtr below ground level to 85 mtr depth below ground level in any strata by mechanical percussion method below ground level including electrical logging through any kind of strata soils/rocks, disposal of surplus soil keeping space for pea gravel packing and including lowering and extraction of casing pipes complete all as specified and as directed :- Notes : (a) Record shall be maintained for regular sample of cutting after every 3 metre interval to be collected and kept at site (b) The bore/tube well should be constructed by the agency as approved by GE (East) Fzr. (c) The Rates also includes transportation of Rig Machine & T&P at Site. (d) Trail Bore will be drilled, if sufficient wet strata is available then ERW casing will be lowered. In case Strata is not available payment only for drilling will be made
80All as per Srl item No. 11.04 here-in-before but from 85 m below ground level to 110 m depth below ground level.
81All as per Srl item No. 11.04 here-in-before but from 110 m below ground level to 135 m depth below ground level.
82Material and labour for Drilling of 450 mm bore hole from 135 mtr below ground level to 160 mtr depth below ground level in any strata by mechanical percussion method below ground level including electrical logging through any kind of strata soils/rocks, disposal of surplus soil keeping space for pea gravel packing and including lowering and extraction of casing pipes of following diameters complete all as specified and as directed :- Notes : (a) Record shall be maintained for regular sample of cutting after every 3 metre interval to be collected and kept at site (b) The bore/tube well should be constructed by the agency as approved by GE (East) Fzr. (c) The Rates also includes transportation of Rig Machine & T&P at Site. (d) Trail Bore will be drilled, if sufficient wet strata is available then ERW casing will be lowered. In case Strata is not available payment only for drilling will be made
83All as per Srl item No. 11.07 here-in-before but from 160 m below ground level to 185 m depth below ground level.
84All as per Srl item No. 11.07 here-in-before but from 185 m below ground level to 200 m depth below ground level.
85Material and labour for electrical Logging of bore well and after electrical logging report of Assembly Design and submission of lithological log report for approval of GE complete.
86Supply and fixing 350 mm bore ERW mild steel housing pipe 8mm wall thickness duly painted with primer and anti-corrosive paint with screwed and socket ends in standard length of 3 metre or as required at site, complete with coupling, welding at joints as required (ISI marked : IS-4270-1992) including cutting,lowering, jointing and fixing in position, complete all as specified (Measured net as fixed).
87All as per Srl item No. 11.11 here-in-before but 250 mm bore pipe with 8 mm wall thickness.
88Supply and fixing low carbon galvanised iron screen filter (slotted) 250mm bore pipe with slots 0.2 mm to 1.5 mm, 6.4mm wall thickness duly painted with ferrous primer and anti-corrosive bituminous paint including screwed and socket ends in standard length, welding and fixing support having slots 0.2 mm to 1.5 mm depending upon nature of aquifers sediments, complete including lowering and fixing in position, confirming to IS-4270-1992, complete all as specified (Measured net as fixed)
89Supply and fixing Mild steel reducing socket for connecting 350mm bore housing pipe with 250mm bore blind pipe with minimum 8.0 mm wall thickness including welding and fixing support complete all as specified and directed
90Supply and fixing Mild steel bail plug suitable for 250 mm bore pipe 1.5 metre long having wall thickness of 8.0 mm with strong iron hooks, complete all as specified and directed
91Supply and fixing well cap fabricated out of 6 mm thick mild steel sheet for 350mm bore housing pipe threaded similar to housing pipe with handle made and of 20mm dia mild steel round bar, complete all as specified and directed
92Material and labour for mild steel flat iron 75mmx6mm as centre guides (set of three), standard pattern for 350/250 mm bore housing pipe complete all as specified and directed
93Material and labour for MS clamps made out of flat iron 125mmx12mm and 01 metre long with nut, bolts of 22mm dia of suitable length for 350mm bore housing pipe complete all as specified and directed
94Material and labour for mild steel structural steel E-250 grade 410W (ISMB-150) fixed independently without connecting plateincluding two coats of black paint over a coat of red oxide complete all as specified and directed
95Material and labour for Strata sample box, made out of 1st class soft wood (deodar) having appropriate internal dimensions 1000mm×600mm×100mm with open-able glass shutter using 4mm thick plain sheet glass having pigeon holes as approved, 2 Nos butt hinges of suitable size and 75mm long hasp staple 01 No having not less than 25 compartments capable of holding 480 to 540 grams of strata sample, including painting wooden surfaces with two coats of synthetic enamel paint (grey) over a coat of pink primer complete all as specified and as directed
96Material and labour for 10mm thick (structural steel should be Fe-290 (Grade-E-165) mild steel black plate of size 600mm dia & cut into two semi-circular equal parts with 350 mm dia hole in the centre complete all as directed by Engineer-in-Charge.
97Material and labour for pea gravel of size 1.5mm to 4.5mm packed all around 350mm bore housing pipe and 250mm bore blind pipe, strainer pipe upto entire depth as required at site in newbore-well, complete all as specified and directed. Note:- For the purpose of measurement, gravel brought by the contractor shall be stacked properly at site & measurements of stack shall be carried out before use and after use(left unused) to arrive at the net qty of gravel used by the contractor in the work & payment against this item shall only be made for the qty of gravel used in the work not for the total qty of gravel brought.
98Material and labour for testing and developing the bore well by means of aircompressor5000 PSItill sand free clear water discharge is obtained to achieve maximum yield of suitable capacity for first 24 hours running complete all as specified and directed Note : All equipments shall be arranged by contractor athis own cost.
99All as per Srl item No. 11.23 here-in-before but beyond 24 Rs.
100Material and labour for yield testing of the tube well by means of engine driven pumping set of suitable capacity, the discharge shall be measured by providing orifice system or ‘V’ notch fixed to steel tank of adequatecapacity complete all as directed by Engineer-in-Charge. Note : All equipments arranged by contractor at his cost & rates are deemed to be included in quoted rates.
101Testing portability of water by chemical analysis such as PH Value, dissolved solids, hardness as CaCo3 and Calcium, Magnesium, Chlorides, sulphate, nitrate, alkality, Iron Turbidity NTU, mineral oil, colour hazen units, taste, odour, residual free chlorine, total Coliform per 100mm (microbiological test) and E Coli as per 100ml (microbiological test) as well as bacteriological portability from any Govt lab complete all as directed by Engineer-in-Charge.
102Supply, installation, commissioningand testing of submersible pump set V-8Multistage (As per mfg design stage ( min 4 stage)) electric driven 2900 RPM of capacity not less than 780 LPM at not less than 90mtr head water lubricated suitable for 200/250mm bore and 150 mm dia discharge pipe coupled with squirrel cage induction electric motor 3 phase 415 volts of capacity not less than 30 HP having CI casing & Gun Metal impeller fitted with delivery pipe etc as reqd at sitewith suitableelectric motor, B class insulation, IP-68 Protection and electric connection With following MOC: Stainless Steel Impeller, Stainless Steel Pump Shaft, LTB Pump Bushes, Cast Iron Bowl/Stage Casing; complete all as directed by Engineer-in-Charge.
103Supply and fixing Flat Submersible cable PVC multi-stranded copper conductor 3 core 16 sqmm from LT Panel/ star-delta starter to pump motors complete all as directed by Engineer-in-Charge.
104Supply and fixing mild steel Columnpipe heavy duty5.4 mm wallthickness 100 mm dia in 3 m length includingflanged both side including provision of nuts, bolts, gasket etc including lowering and fixing complete all as directed by Engineer-in-Charge.
105Supply, installation, testing and commissioning in replacement of CPRI approved, factory made, LT panel board cubical, indoor type, floor mounted double door, suitable for AC, 3 phase 4 wire, 50 cycles, 415 Volts,Front & Rear openable double door with locking arrangement. The panel board shall be made of 2.0 mm thick CRCA/MS sheet (Min size 1.2 m x 1.0 m x 0.45 m) with Synthetic enamel Paint both side.The panel have to provide proper compartment as per IS specification and wiring of panel with suitable size of copper conductor FRLS cable not less than 2.5 Sqmm ,gaskets thimbles including cable entry glands, all as directed. Base frame of the panel shall bemade of angle iron of size 50 x50 x 6mm of upto 1/2 mtr height from GL& 1/2 mtr for Below GL in PCC (1:3:6) type C-2 using 40 mm stone aggregatescomprising of following:- (i) Panel having common aluminium bus bar of capacity 400 Amp TPN each ( Size 40mm x10 mm) and suitable capacity TPN bus bar for outgoing MCCB"s, including aluminium lugs to connect the cable and cable gland for Each cable entry as per cable size (ii) INCOMING (a) (a) MCCB Adjustable type thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 200 Amp 4 Pole ICU= 36 KA with overload variation 40-100%- 01 No (iii) OUTGOING (a)MCCB thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 100 Amp 4 Pole ICU = ICS = 16 KA- 01 No.Make : ABB/SIEMENS/SCHNEIDER.(outgoing) (b) MCCB thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 63 Amp 4 Pole ICU = ICS = 16 KA- 01 No.Make : ABB/SIEMENS/SCHNEIDER.(outgoing) (c) MCB TPN 63 Amps -01 Nos (d) ON LOAD Change over switch 200 Amps -01 No (e) Automatic star delta submersible starter DLX (with short circuit protection) HGS series suitable for 30-35 HP motor provided with protection degree IP-54 and FRLS internal wiring and extended wide bend coil and in-built metering and contactor size is MN 50 and Overload relay Range 28 A-40 A and TP MCB rating 100 Amps and Starter should be provided with Single phase preventer etc all as directed. (iv) Volt Meter 0 - 500 Volts digital type square shapeflush mounted with selector switch - 1 No (v) Ammeter 0 - 200 Amps digital type square shape 96mm flush mounted with selector switch and CT"s 200/5 A - 1 No. (vi) Indicator lamp RYB : 01 Set, with Suitable CT Coil complete
106Supply, installation and testing of Heavy duty Chemical Dosing system plunger type suitable to inject solution upto 25 LPH, working pressure 10 kg /cm square comprising dosing pump coupled with three phase electric motor of capacity 0.5 HP,1440 RPM assembled with agitator in one motor , agitator with SS sweep blade duly FRP coated, FRP tank 150 ltrs capacity, complete unit mounted on heavy duty panited with MS fabricated frame duly anticorrosive paint, with Chemical grade PVC NRV including inlet /outlet check valve all connections ,connecting CPVC/UPVC/PVC Fittings ,Pipe etc complete all as required at site and as directed by Engineer-in-Charge.
107STP WORKS
108Design, Supply, construction, installation, testing & commissioning of Sewage Treatment Plant 100 KLD based on principle of aerobic attached growth non-clogging randomly Moving Bed Bio-reactor (MBBR) prefab type, including required foundations and & covering of all motors with MS sheets covers & the following :- (a) One no. Fine bar screen chamber fitted with screen of MS epoxy construction as per given minimum specifications, to be installed in Fine Barscreen chambers, provided at an angle of 60° to prevent floating objectspassing through it and subsequently removing manually and dumped forfurther disposal (b) One No. Oil & Grease Removal Chamber in RCC construction with design mix concrete of grade M-30, for removal of free floating Oil & Grease in the sewage, as per given specifications (c) One No. Equalisation tank in RCC construction with design mix concrete of grade M-30, as per given specifications, to cater for the peak discharge including provision of diffused air to ensure that septic conditions do notoccur in tank at all. One lot of air grid for equalization tank for providingaeration in the tank, as specified in PS. (d) Two Nos. raw sewage pumps complete with motor and all necessaryaccessories and fittings, to be installed for transferring sewage fromequalization tank to process reactor. Level sensor should be provided in the tank and interlinked with pumps for ON-OFF operation as per water level in the tank. One pressure gauge for each pump has to be provided to measure pressure at the outlet. (e) Two nos. Air blower complete with motor and all necessary accessorieSupply and fixingittings, for providing air in equalization tank, MBBR reactors & Sludge holding tank. One no. Air rotameter is to be provided in each line to MBBR reactor 1 & 2, & EQT for measurement of quantity of air. (f) One lot of anoxic chamber in MSEP construction with internals comprising of media and MSEP Mixer.
109(g) Two lot of MBBR Tank in MSEP construction with internals comprising of media, SS air grid & SS rise pipe, media retaining sieves, etc. (h) One Lot of Tube settler tank in MSEP construction with internals comprising of media, supporting structure & collection trough. (j) Two Nos. sewage centrifugal mono-block self-priming recirculation pumps complete with motor and all necessary accessories and fittings. One pressure gauge for each pump is provided to measure pressure at the outlet. (k) One No. Chlorine Contact cum Filter feed tank in in MSEP construction, as per given specifications. With one set of chlorine dosing system comprising of solution tank and dosing pumps, as specified in PS, with necessary connection for dosing of solution in chlorine contact tank. (l) Two Nos. filter feed centrifugal monobloc pumps complete with motor and all necessary accessories and fittings for feeding tertiary unit, Level sensor should be provided in the chlorine contact cum filter feed tank andinterlinked with pumps for ON-OFF operation as per level in the sump. Onepressure gauge for each pump is provided to measure pressure at theoutlet (m) One No. Dual Media filter, complete with media, frontal piping, valve andpressure gauges to measure pressure across the filter. (n) One No. Activated Carbon Filter of, complete with media, frontal piping, valve and pressure gauges to measure pressure across the filter (o) One No. Treated Water tank in MSEP construction, to receive supernatant coming from tertiary treatment plant, as per given specifications (p) Two Nos. sludge transfer self-priming mono-block pumps complete with motor and all necessary accessories and fittings. One pressure gauge for each pump has to be provided to measure pressure at the outlet
110(q) One No. Continuous feed sludge screw press with dosing system for sludge dewatering system as specified in PS (r) One No. MCC Panel for operation of all electromechanical units of sewage treatment plant (s) One lot of suitable size Piping & valves of suitable material to interconnect various units as per site layout. (t) One lot of Power & control cables to interconnect various drives and instrumentations with STP panel. (u) One lot of foundations in PCC for all E&M equipment, as required. Note :The prices for Design, Supply,construction, installation, testing and commissioning of 100 KLDSTP based on MBBR technologyincluding all civil, electromechanical andinstrumentation works as per thespecifications given in technical specification including requiredfoundations.
111Supply and fixing of Non Clog Centrifugal sewage pump having 20 mtr Head, Capable of delivering approx. 937.5 LPM at 20 mtr Head with 10 HP AC Electric Motor 3 Phase, 415V, 50C/S, 1450RPM directly coupled on a common base frame complete all as directed by Engineer-in-Charge. Make: Kirloskar/ KSB/ Crompton
112Supply and fixing cast iron foot valve flanged end conforming to IS 4038 PN 0.2, 100 mm (4”) dia size all as specified and directed
113Supply, installation, testing and commissioning in replacement of CPRI approved, factory made, LT panel board cubical, indoor type, floor mounted double door, suitable for AC, 3 phase 4 wire, 50 cycles, 415 Volts,Front & Rear openable double door with locking arrangement. The panel board shall be made of 2.0 mm thick CRCA/MS sheet (Min size 1.2 m x 1.0 m x 0.45 m) painted with Synthetic enamel Paint both side.The panel have to provide proper compartment as per IS specification and wiring of panel with suitable size of copper conductor FRLS cable not less than 2.5 Sqmm, gaskets thimbles including cable entry glands, all as directed. Base frame of the panel shall bemade of angle iron of size 50 x50 x 6mm of upto 1/2 mtr height from GL& 1/2 mtr Below GL in PCC (1:3:6) type C-2 using 40 mm graded stone aggregatescomprising of following:- (i) Panel having common aluminium bus bar of capacity 400 Amp TPN each ( Size 40mm x10 mm) and suitable capacity TPN bus bar for outgoing MCCB"s, including aluminium lugs to connect the cable and cable gland for Each cable entry as per cable size (ii) INCOMING (a) MCCB Adjustable type thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 100 Amp 4 Pole ICU= 16 KA with overload variation 40-100%- 01 No (iii) OUTGOING (a)MCCB thermal released based with overload short circuit and earth fault protection and inbuilt earth release suitable size and capacity, 63 Amp 4 Pole ICU = ICS = 16 KA- 02 Nos (c) MCB SPN 32 Amps -01 No (d) ON LOAD Change over switch 100 Amps -01 No (e) Automatic star delta submersible starter ASD (with short circuit protection) HSG series suitable for 10-12.5 HPmotor provided with protection degree IP-54 and FRLS internal wiring and extended wide bend coil and in-built metering and contactor size 18 and Overload relay Range 8 A-12 A and class H Insulation and Starter should be provided with Single phase preventer etc all as directed. (iv) Volt Meter 0 - 500 Volts digital type square shapeflush mounted with selector switch - 1 No (v) Ammeter 0 - 200 Amps digital type square shape 96mm flush mounted with selector switch and CT"s 200/5 A - 1 No. (vi) Indicator lamp RYB :01 Set. with Suitable CT Coil complete
114Outsourcing of Manning / Operation & routine periodical maintenance of electro -Mechanical equipment’s, control valves, instrumentals etc of STP 100 Cum/day (for Two shifts per day including Sunday & holiday, by employing One FGM (Semi skilled operator) and One helper per Shift (each shift of eight hours) and maintaining desired level of BOD/COD, TSS, TKN by dosing of required quantity of chemicals as per OEM recommendation complete for a period of 11 months starting from the next day of certified date of completion of Phase-I (to be intimated by GE through Work Order separately) complete all as specified and directed. Note :- (a) Maintenance of log sheet and all maintenance records shall be responsibility of the contractor and no stationary shall be provided by the Department. Format of log sheet and records etc shall be decided by GE/ Engineer -in-charge (b) The contractor is responsible to maintain the installations and surrounding area in presentable manner through out the period. The shift timings shall be decided by Engineer- in- charge and liable to change as and when required by Engineer- incharge. (c) Area cleaning surrounding the plant room & inside the plant room etc shall be responsibility of the contractor (d)The contractor shall be maintain clear record of attendance for workmen/ staff. (e) Consumables i.e grease, lubricant oil, cotton waste washers etc required for routine maintenance of STP shall be provided by contractor and cost of the same shall be deemed to be included in unit rates quoted. (f) Cost of stationary required for attendance register, meter readings, site order books, log sheets etc shall be provided by contractor and cost of same shall be deemed to be included in unit rates quoted by contractor. (g) FGM/ Operator should be ITI qualified in respective trade i.e. electrical/ fitter and having minimum 2 years experience in similar trade/ works. (h) Helper should be having 2 years experience in similar trade (j) Timing of shift shall be as decided by Engineer-in-Charge and as specified .
115TREATED SEWAGE WATER SUPPLY WORKS
116Supply and fixing 3 phase horizontal, radially split volute casing centrifugal pump 3 HP in back pull out design, single stage, single entry with radial impeller equipped with VFD devices & equipped with speed control panel to control speed/ discharge pump set capacity of discharge 500 LPM at delivery head of 22mtr of IE 3* & with MOC material CI/ bronze with suitable electrical panel, cable & starter complete all as directed by Engineer-in-Charge.
117Supply and fixing motor starter for 3 HP pumping sets, centrifugal, electric driven having extended wide bend, coil, FRLS internal wiring, providing with protection degree IP 54, starter type air break, class H insulation complete all as directed by Engineer-in-Charge.
118Supply and fixing PPR gate valves (brass insert) of 160mm bore complete all as specified and directed
119Supply and fixing PPR gate valves (brass insert) of 75mm bore complete all as specified and directed
120Supply and fixing cast iron air valve with single air outlets, conforming to IS : 14845 of size 50mm bore and fixing up in cast iron water supply mains of size 100mm bore complete all as specified and directed
121Supply and fixing cast iron air valve with single air outlets, conforming to IS : 14845 of size 50mm dia and fixing up in cast iron water supply mains of size 150mm dia complete all as specified and directed
Disclaimer :