Kerala Water Authority-KWA has published Tender For State Plan-2022-23 - Uwss To Kottayam-Supply, Erection, Testing And Commissioning Of 180 Hp Vertical Turbine Pump Set At Rwph Thiruvanchoor. -Pipeline Work-1. Submission Date for this Tender is 18-01-2023. Submersible Pump Tenders in Kottayam Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

35728634
Tender For State Plan-2022-23 - Uwss To Kottayam-Supply, Erection, Testing And Commissioning Of 180 Hp Vertical Turbine Pump Set At Rwph Thiruvanchoor. -Pipeline Work-1
Open Tender
Indian
Kerala
Kottayam
18-01-2023

Tender Details

Tender For State Plan-2022-23 - UWSS to Kottayam-Supply, Erection, testing and commissioning of 180 HP Vertical Turbine pump set at RWPH Thiruvanchoor. -Pipeline Work-1

Key Value

Document Fees
INR 2500 /-
EMD
INR 46100.0 /-
Tender Value
Refer document

BOQ Items

Work Name:State Plan-2022-23 - UWSS to Kottayam-Supply, Erection, testing and commissioning of 180 HP Vertical Turbine pump set at RWPH Thiruvanchoor. -Pipeline Work-1
Sl. No. Item Description
1APPENDIX-A
2OD55469/2022-2023:Supply and erection of Vertical Turbine pump set with the following specification<br>1, Pump set and accessories<br>Supply, erection, testing and commissioning of KWA pre-qualified reputed make ISI marked high efficiency type, self water lubricated above floor discharge type vertical turbine pump withbronze or Stainless steel impeller, SS Shaft, CI pump casing , MS Fabricated (minimum -8 mm ) flangedcolumn assembly with Stainless Steel strainer and all accessories conforming to IS 1710. The pump shallbe coupled with suitable vertical solid shaft motor specified in item No.2 Details are given below. <br>Theduty condition is as follows. <br>Discharge - 7320 lpm, <br>Total head - 79 mtrs.<br>Depth of well - 12 m<br>Size of pumping main - 600 mm<br>Maximum length of column pipe -Below 1.5m<br>Casing -Cast iron or Stainless Steel.<br>Speed - Below 1500 rpm <br>Impeller-Enclosed type brozne LTB 2 or Stainless Steel dynamically balanced as per ISO 1940 grade 3 standards<br>Sleeve -SS 304<br>Column shaft -SS 316<br>Pump shaft -SS 316<br>Bowl casing ring - Bronze LTB 2<br>Epoxypainted MS Column pipe of 8 mm thick flanged ends each having length below 1.5 meter. Strainerfabricated with SS 304. bearings for spider is made bowl synthetic rubber with outer brass / CI shell.Minimum Efficiency -suitable to Achieve minimum 70 % combined efficiency for pump and motor.(vibrations should be limited as per HIS 9.6.4.3 standards pump performance tolerance should be subjectto Hydrate institute standards class A - No negative tolerance is applicable in efficiency and no positivetolerance in power) <br> 2, Motor - Supply, erection, testing and commissioning of suitable rating high efficiency KWA pre-qualified reputed make Squirrel cage induction, TEFC, Vertical solid shaft motorsuitable for direct coupling with above pump having RPM Below 1500 or nearest capable to operate on voltage -415 V (+ /- 10%) 50 HZ (+ /- 3%) AC 3 phase, 50 degree ambient temp rise . Conforming torelevant IS . Motor shall be energy efficient and supporting certificates to prove EFI or EF2. <br>3, Starter - Supply, erection, testing and commissioning of 400/440 V indoor,totally Enclosed,Dust tight and verminproof, suitable rating DIGITAL SOFT STARTER for the above motor with motor protections ( over voltage and under voltage,Under current, Over current, Locked rotor,Earth fault, Current Unbalance, singlephasing , Phase sequence reversal and Dry run protection ) with main contactor and bypass contactor and semi conductor fuses as per IE rules and code of practice etc. complete. The Starter panel shall befitted on a common base frame (height -50 Cm) on suitable Concrete foundation.<br> 4, Supply and fixing of suitable size best quality, ISI marked PN-1.6, heavy duty CI double flanged sluice valve as perIS-14846-2000<br> 5, Supply and fixing of suitable size best quality, ISI marked, heavy duty cast iron,Double flanged Reflex non return valve as per IS 5312 suitable for the above pump set. Fitting ofvalves shall include proper RCC support especially for Non return valves. <br>6, Supply and fixing of Reputed make suitable size and correct range Glycerine filled pressure gauge with Steel Ball type StopCock, steel syphon tube and all accessories suitable for the above pump set. <br>7, Panel board - Design,Engineering, Supply, erection, testing and commissioning of medium voltage sheet steel clad,totally enclosed Dust tight and vermin proof,indoor floor or Wall mounted cubical type common control panel board fabricated out of 16 SWG mild steel sheet,air insulated and of adequate size as mentionedbelow,for operation on 3 Phase 4 Wire 415 volts,50 HZ, AC supply system consisting of 1 No. suitable capacity and correct range MCCB as incomer and fitted with 3 Nos of indicator LED lamps, 1 No. volt meter with selector switch, 1 No. Ammeeter(Correct range) with selector switch and Controlling Circuit 2 AMPS C CLASS 1 POLE MCB s- 3 Nos etc. The switch board surface treated after de greasing, pickling, phosphating etc anti rust primer coating followed by two coats of spray paint of approved shade as standard construction practice approved by the kerala electrical inspectorate standard and as standard practice. The panel shall be fitted on a common base frame on wall or floor mounted (height-50 cm) with suitable Concrete foundation.<br>8, Cabling work. <br>Supply, laying, termination, and connecting of XLPE cable of Correct size and gauge, laid in cable tray suitable for motor as per the rules of Electrical PRICE EST NO:2022/17844 printed on 28-08-2022 22:32:28 page 2 Kerala Water Authority P R I C E inspectorate including taking power connection from Main panel board to Sub Panel, starter and from starter to motor,capacitor for the above pump set considering energy conservation as per IE standards.including termination materials such as gland, Socket, gland earth etc as per IE rules. <br>9, Supply of all materials and providing cable End termination of the XLPE cable of suitable size for giving power connections to Panel Board, Starter,motor,Capacitor etc compleate as per IE Standards.<br>10 - PIPE Earthing<br>Supply and providing ISI Pipe earthing as per IS 3043 with 3 meter long 50 mm dia C class Galvanised iron pipe, providing GI funnel with well mesh at the top. Fixing 50 x 5 mm GI flat and with 12x 10 mm bolt and nut at the top of the GI pipe. select an earth pit site atleast 1.5 metres away from the building foundation. Dig an earth pit of dimentions 1 m length x 1 m width x 3m deapth.place the GI pipe (50 mm dia C class having 3 m length and 12 mm dia holes) into the earth pit. filling around the GI pipe at a radious of 15 cm and to a height of about 15 cm with a homogeneous mixture of charcoal and salt upto a height of 3 meter from the bottom. fill up the surrouding extra area with soil. including watering and ramning , providing brick work masonary in 1:6 cement mortar at the top, Plastering the inside and top of the manhole with 12 mm thick 1:6 cement mortar. fixing cast iron gully trap with CI covering at the top. <br>Supply,laying and giving Earthing connections, terminations (Tin or Nickel Plated copper lugs) of correct size of Copper Strip/Wires for Required length and Size for Double Earthing to Main panel board, Sub Panel, starter, motor,capacitor And Connecting to Existing Earth Bus and pit . All joints in earthing counductors and earth bus shall be properly tinned or solderd etc as per IE standards. Earth conductor is covered with PVC pipe 10 kg/CM2 to earth pit.<br>11 - Capacitor<br>Supply, erection, testing and commissioning of Ultra heavy duty APP 440 V,50 HZ Box capacitor With capacitor Duty Contactor, MCB/MCCB, fixing stand connecting copper cables, termination etc for the motor to get a power factor above 0.99 The capactior shall confirm to IS 2834/1986.<br>12 - Delivery Pipe connections. <br>Supplying,fabricating and erecting pumping header & Delivery pipe of required size with Y connection and necessary joints made out of GI (c class) /Primer and Emulsion coated MS pipe of thickness not less than 8 mm for a suitable length with required flanged joint and seating on supports as per site condition and as per the direction of departmental officers. Connecting valve with suitable flanges, nuts, bolts and IR sheet etc.complete and connecting the delivery side of the pump with the valves and suitable specials to connect with pumping main and leaking water from pump gland to be collected to 40 mm PVC pipe(16 kg/cm2) and discharged out side of the pump house at suitable place as directed by the department officers. . <br>13 - Erecting the above motor pump set in suitable concrete foundation with M:30 mix NSBS of suitable and correct size (minimum height is 30cm) and reinforcement12 mm torsteel in mesh in all directions and fixing foundation bolt to suitable base of the pumpsets as directed by department officers.
3OD55470/2022-2023:Supply, laying, testing and commissioning of new 3.5 core aluminum XLPE armored cables with suitable size (CEA regulation) and length with all accessories. The new cable fixing from L.T side breakers to starter panels, starters, motors and capacitors for existing 4 nos 150, 175, 170 and 175 HP V.T motors. Fixing the cables in new cable tray with all accessories fixing in wall (minimum height - 4 m) in raw water pump house as per electrical inspectorate rules and as per the direction of departmental officers.