Municipal Adminitration And Water Supply Department-MAAWSD has published Tender For Attending Leak Work At West Zone Ward No 15 To 19 30 To 37 42 44. Submission Date for this Tender is 27-01-2023. Couplers Tenders in thoothukudi Tamil Nadu. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Attending 90mm dia PVCPipe 4KSC leakupto a depth of 1.20m including Bt road cutting,Earth work for ordinary soil, Dewatering charges using 5HP motor , replacing PVC pipe withCoupler charges and refilling the trench after verfiying the leak including all cost of material and labour charges etc complete |
2 | Attending 110mm dia PVCPipe 4KSC leakupto a depth of 1.20m including Bt road cutting,Earth work for ordinary soil, Dewatering charges using 5HP motor , replacing PVC pipe withCoupler charges and refilling the trench after verfiying the leak including all cost of material and labour charges etc complete |
3 | Attending 110mm dia PVCPipe 4KSC leakupto a depth of 1.50m including Bt road cutting,Earth work for ordinary soil, Dewatering charges using 5HP motor , replacing PVC pipe withCoupler charges and refilling the trench after verfiying the leak including all cost of material and labour charges etc complete |
4 | Attending 110mm dia PVCPipe 4KSC leakupto a depth of 1.80m including Bt road cutting,Earth work for ordinary soil, Dewatering charges using 7.5HP motor , replacing PVC pipe withCoupler charges and refilling the trench after verfiying the leak including all cost of material and labour charges etc complete |
5 | Attending 110mm dia PVCPipe 4KSC leakupto a depth of 2.10m including Bt road cutting,Earth work for ordinary soil, Shoring, and strutting with sheet pilesby driving on both sides of the trench from Ground Level up to the required dept, Dewatering charges using 7.5HP motor , replacing PVC pipe withCoupler charges and refilling the trench after verfiying the leak including all cost of material and labour charges etc complete |
6 | Attending 140mm dia PVCPipe 4KSC leakupto a depth of 1.20m including Bt road cutting,Earth work for ordinary soil, Dewatering charges using 5HP motor , replacing PVC pipe withCoupler charges and refilling the trench after verfiying the leak including all cost of material and labour charges etc complete |
7 | Attending 140mm dia PVCPipe 4KSC leakupto a depth of 1.50m including Bt road cutting,Earth work for ordinary soil, Dewatering charges using 5HP motor , replacing PVC pipe withCoupler charges and refilling the trench after verfiying the leak including all cost of material and labour charges etc complete |
8 | Attending 140mm dia PVCPipe 4KSC leakupto a depth of 1.80m including Bt road cutting,Earth work for ordinary soil, Dewatering charges using 7.5HP motor , replacing PVC pipe withCoupler charges and refilling the trench after verfiying the leak including all cost of material and labour charges etc complete |
9 | Attending 140mm dia PVCPipe 4KSC leakupto a depth of 2.10m including Bt road cutting,Earth work for ordinary soil, Shoring, and strutting with sheet pilesby driving on both sides of the trench from Ground Level up to the required dept, Dewatering charges using 7.5HP motor, replacing PVC pipe withCoupler charges and refilling the trench after verfiying the leak including all cost of material and labour charges etc complete |
10 | Attending 160mm dia PVCPipe 4KSC leakupto a depth of 1.20m including Bt road cutting,Earth work for ordinary soil, Dewatering charges using 5HP motor, replacing PVC pipe withCoupler charges and refilling the trench after verfiying the leak including all cost of material and labour charges etc complete |
11 | Attending 160mm dia PVCPipe 4KSC leakupto a depth of 1.50m including Bt road cutting,Earth work for ordinary soil, Dewatering charges using 5HP motor, replacing PVC pipe withCoupler charges and refilling the trench after verfiying the leak including all cost of material and labour charges etc complete |
12 | Attending 160mm dia PVCPipe 4KSC leakupto a depth of 1.80m including Bt road cutting,Earth work for ordinary soil, Dewatering charges using 7.5HP motor, replacing PVC pipe withCoupler charges and refilling the trench after verfiying the leak including all cost of material and labour charges etc complete |
13 | Attending 160mm dia PVCPipe 4KSC leakupto a depth of 2.10m including Bt road cutting,Earth work for ordinary soil, Shoring, and strutting with sheet pilesby driving on both sides of the trench from Ground Level up to the required dept, Dewatering charges using 7.5HP motor , replacing PVC pipe withCoupler charges and refilling the trench after verfiying the leak including all cost of material and labour charges etc complete |
14 | Attending 180mm dia PVCPipe 4KSC leakupto a depth of 1.20m including Bt road cutting,Earth work for Ordinary soil, Dewatering charges using 5HP motor , replacing PVC pipe withCoupler charges and refilling the trench after verfiying the leak including all cost of material and labour charges etc complete |
15 | Attending 180mm dia PVCPipe 4KSC leakupto a depth of 1.50m including Bt road cutting,Earth work for Ordinary soil, Dewatering chargesusing 5HP motor , replacing PVC pipe withCoupler charges and refilling the trench after verfiying the leak including all cost of material and labour charges etc complete |
16 | Attending 180mm dia PVCPipe 4KSC leakupto a depth of 1.80m including Bt road cutting,Earth work for Ordinary soil, Dewatering charges using 7.5HP motor , replacing PVC pipe withCoupler charges and refilling the trench after verfiying the leak including all cost of material and labour charges etc complete |
17 | Attending 180mm dia PVCPipe 4KSC leakupto a depth of 2.10m including Bt road cutting,Earth work for ordinary soil, Shoring, and strutting with sheet pilesby driving on both sides of the trench from Ground Level up to the required dept, Dewatering charges using 7.5HP motor, replacing PVC pipe withCoupler charges and refilling the trench after verfiying the leak including all cost of material and labour charges etc complete |
18 | Attending 200mm dia PVCPipe 4KSC leakupto a depth of 1.20m including Bt road cutting,Earth work for Ordinary soil, Dewatering charges using 5HP motor , replacing PVC pipe withCoupler charges and refilling the trench after verfiying the leak including all cost of material and labour charges etc complete |
19 | Attending 200mm dia PVCPipe 4KSC leakupto a depth of 1.50m including Bt road cutting,Earth work for Ordinary soil, Dewatering charges using 5HP motor, replacing PVC pipe withCoupler charges and refilling the trench after verfiying the leak including all cost of material and labour charges etc complete |
20 | Attending 200mm dia PVCPipe 4KSC leakupto a depth of 1.80m including Bt road cutting,Earth work for Ordinary soil, Dewatering charges using 7.5HP motor , replacing PVC pipe withCoupler charges and refilling the trench after verfiying the leak including all cost of material and labour charges etc complete |
21 | Attending 200mm dia PVCPipe 4KSC leakupto a depth of 2.10m including Bt road cutting,Earth work for ordinary soil, Shoring, and strutting with sheet pilesby driving on both sides of the trench from Ground Level up to the required dept, Dewatering charges using 7.5HP motor, replacing PVC pipe withCoupler charges and refilling the trench after verfiying the leak including all cost of material and labour charges etc complete |
22 | Attending 110mm dia HDPEPipe PN6 leak upto a depth of 1.20m including Bt road cutting, Earth work foordinary soil, Dewatering charges using5HP motor , replacing HDPE pipe withHDPEmould Electro Fusion Coupler, Jointing electro fusion welding charges and refilling the trench after verfiying the leak including all cost of material and labour charges etc complete |
23 | Attending 110mm dia HDPEPipe PN6 leak upto a depth of 1.20m including Bt road cutting, Earth work foordinary soil, replacing HDPE pipe withHDPEmould Electro Fusion Coupler, Jointing electro fusion welding charges and refilling the trench after verfiying the leak including all cost of material and labour charges etc complete |
24 | Attending 110mm dia HDPEPipe leak in Electrofusion saddle location upto a depth of 1.20m including Bt road earth work charges, Earth work foordinary soil, Dewatering charges using5HP motor ,and refilling the trench after verfiying the leak including all cost of material and labour charges etc complete |
25 | Attending 140mm dia HDPEPipe PN6 leak upto a depth of 1.20m including Bt road cutting, Earth work for ordinary soil, Dewatering charges using5HP motor , replacing HDPE pipe withHDPEmould Electro Fusion Coupler, Jointing electro fusion welding charges and refilling the trench after verfiying the leak including all cost of material and labour charges etc complete |
26 | Attending 140mm dia HDPEPipe PN6 leak upto a depth of 1.20m including Bt road cutting, Earth work for ordinary soil,replacing HDPE pipe withHDPEmould Electro Fusion Coupler, Jointing electro fusion welding charges and refilling the trench after verfiying the leak including all cost of material and labour charges etc complete |
27 | Attending 160mm dia HDPEPipe PN6 leak upto a depth of 1.20m including Bt road cutting, Earth work for ordinary soil, Dewatering charges using5HP motor, replacing HDPE pipe withHDPEmould Electro Fusion Coupler, Jointing electro fusion welding charges and refilling the trench after verfiying the leak including all cost of material and labour charges etc complete |
28 | Attending 160mm dia HDPEPipe PN6 leak upto a depth of 1.20m including Bt road cutting, Earth work for ordinary soil, replacing HDPE pipe withHDPEmould Electro Fusion Coupler, Jointing electro fusion welding charges and refilling the trench after verfiying the leak including all cost of material and labour charges etc complete |
29 | Attending 180mm dia HDPEPipe PN6 leak upto a depth of 1.20m including Bt road cutting, Earth work for ordinary soil, Dewatering charges using5HP motor, replacing HDPE pipe withHDPEmould Electro Fusion Coupler, Jointing electro fusion welding charges and refilling the trench after verfiying the leak including all cost of material and labour charges etc complete |
30 | Attending 180mm dia HDPEPipe PN6 leak upto a depth of 1.20m including Bt road cutting, Earth work for ordinary soil, replacing HDPE pipe withHDPEmould Electro Fusion Coupler, Jointing electro fusion welding charges and refilling the trench after verfiying the leak including all cost of material and labour charges etc complete |
31 | Attending 200mm dia HDPEPipe PN6 leak upto a depth of 1.20m including Bt road cutting Earth work for ordinary soil, Dewatering charges using5HP motor , replacing HDPE pipe withHDPEmould Electro Fusion Coupler, Jointing electro fusion welding charges and refilling the trench after verfiying the leak including all cost of material and labour charges etc complete |
32 | Attending 200mm dia HDPEPipe PN6 leak upto a depth of 1.20m including Bt road cutting, Earth work for ordinary soil,replacing HDPE pipe withHDPEmould Electro Fusion Coupler, Jointing electro fusion welding charges and refilling the trench after verfiying the leak including all cost of material and labour charges etc complete |
33 | Attending 100mm dia ACPipe calss 15 leak upto a depth of 1.50m including Bt road cutting, Earth work for ordinary soil, Dewatering charges using 5HP motor , replacing AC pipe withC.I.D Joint class 15 charges and refilling the trench after verfiying the leak including all cost of material and labour charges etc complete |
34 | Attending 100mm dia ACPipe calss 15 leak upto a depth of 1.80m including Bt road cutting, Earth work for ordinary soil, Dewatering charges using7.5hp motor, replacing AC pipe withC.I.D Joint class 15 charges and refilling the trench after verfiying the leak including all cost of material and labour charges etc complete |
35 | Attending 100mm dia ACPipe calss 15 leak upto a depth of 2.10m including Bt road cutting, Earth work for ordinary soil,Shoring, and strutting with sheet pilesby driving on both sides of the trench from Ground Level up to the required dept, Dewatering charges using 7.5hp motor, replacing AC pipe withC.I.D Joint class 15 charges and refilling the trench after verfiying the leak including all cost of material and labour charges etc complete |
36 | Attending 125mm dia ACPipe calss 15 leak upto a depth of 1.50m including Bt road cutting, Earth work for ordinary soil, Dewatering charges using 5hp motor , replacing AC pipe withC.I.D Joint class 15 charges and refilling the trench after verfiying the leak including all cost of material and labour charges etc complete |
37 | Attending 125mm dia ACPipe calss 15 leak upto a depth of 1.80m including Bt road cutting, Earth work for ordinary soil, Dewatering charges using 7.5hp motor , replacing AC pipe withC.I.D Joint class 15 charges and refilling the trench after verfiying the leak including all cost of material and labour charges etc complete |
38 | Attending 125mm dia ACPipe calss 15 leak upto a depth of 2.10m including Bt road cutting, Earth work for ordinary soil,Shoring, and strutting with sheet pilesby driving on both sides of the trench from Ground Level up to the required dept, Dewatering charges using 7.5hp motor, replacing AC pipe withC.I.D Joint class 15 charges and refilling the trench after verfiying the leak including all cost of material and labour charges etc complete |
39 | Attending 150mm dia ACPipe calss 15 leak upto a depth of 1.50m including Bt road cutting, Earth work for ordinary soil, Dewatering charges using 5hp motor , replacing AC pipe withC.I.D Joint class 15 charges and refilling the trench after verfiying the leak including all cost of material and labour charges etc complete |
40 | Attending 150mm dia ACPipe calss 15 leak upto a depth of 1.80m including cutting, Earth work for ordinary soil, Dewatering charges using 7.5hp motor , replacing AC pipe withC.I.D Joint class 15 charges and refilling the trench after verfiying the leak including all cost of material and labour charges etc complete |
41 | Attending 150mm dia ACPipe calss 15 leak upto a depth of 2.10m including Bt road cutting, Earth work for ordinary soil,Shoring, and strutting with sheet pilesby driving on both sides of the trench from Ground Level up to the required dept, Dewatering charges using 7.5hp motor, replacing AC pipe withC.I.D Joint class 15 charges and refilling the trench after verfiying the leak including all cost of material and labour charges etc complete |
42 | Attending 200mm dia ACPipe calss 15 leak upto a depth of 1.50m including Bt road cutting, Earth work for ordinary soil, Dewatering charges using 5hp motor, replacing AC pipe withC.I.D Joint class 15 charges and refilling the trench after verfiying the leak including all cost of material and labour charges etc complete |
43 | Attending 200mm dia ACPipe calss 15 leak upto a depth of 1.80m including Bt road cutting,, Earth work for ordinary soil, Dewatering charges using 7.5hp motor , replacing AC pipe withC.I.D Joint class 15 charges and refilling the trench after verfiying the leak including all cost of material and labour charges etc complete |
44 | Attending 200mm dia ACPipe calss 15 leak upto a depth of 2.10m including Bt road cutting, Earth work for ordinary soil,Shoring, and strutting with sheet pilesby driving on both sides of the trench from Ground Level up to the required dept, Dewatering charges using 7.5hp motor, replacing AC pipe withC.I.D Joint class 15 charges and refilling the trench after verfiying the leak including all cost of material and labour charges etc complete |
45 | Attending 250mm dia ACPipe calss 15 leak upto a depth of 1.50m including Bt road cutting, Earth work for rdinary soil, Dewatering charges using 5hp motor , replacing AC pipe withC.I.D Joint class 15 charges and refilling the trench after verfiying the leak including all cost of material and labour charges etc complete |
46 | Attending 250mm dia ACPipe calss 15 leak upto a depth of 1.80m including Bt road cutting, Earth work for ordinary soil, Dewatering charges using 7.5hp motor, replacing AC pipe withC.I.D Joint class 15 charges and refilling the trench after verfiying the leak including all cost of material and labour charges etc complete |
47 | Attending 250mm dia ACPipe calss 15 leak upto a depth of 2.10m including Bt road cutting, Earth work for ordinary soil,Shoring, and strutting with sheet pilesby driving on both sides of the trench from Ground Level up to the required dept, Dewatering charges using 7.5hp motor, replacing AC pipe withC.I.D Joint class 15 charges and refilling the trench after verfiying the leak including all cost of material and labour charges etc complete |
48 | Attending 300mm dia ACPipe calss 15 leak upto a depth of 1.50m including Bt road cutting, Earth work for ordinary soil, Dewatering charges using 5hp motor , replacing AC pipe withC.I.D Joint class 15 charges and refilling the trench after verfiying the leak including all cost of material and labour charges etc complete |
49 | Attending 300mm dia ACPipe calss 15 leak upto a depth of 1.80m including Bt road cutting, Earth work for ordinary soil, Dewatering charges using 7.5hp motor, replacing AC pipe withC.I.D Joint class 15 charges and refilling the trench after verfiying the leak including all cost of material and labour charges etc complete |
50 | Attending 300mm dia ACPipe calss 15 leak upto a depth of 2.10m including Bt road cutting, Earth work for ordinary soil,Shoring, and strutting with sheet pilesby driving on both sides of the trench from Ground Level up to the required dept, Dewatering charges using 7.5hp motor, replacing AC pipe withC.I.D Joint class 15 charges and refilling the trench after verfiying the leak including all cost of material and labour charges etc complete |
51 | Repair and maintance of existing 100 mm Sluice valve set replacing of brass square bar of size 60mmx60mmx60mm, ( checknut ), MS bolt nut , Rubber gascut with therading , holes and lath work arrangements including all cost of material and labour charges etc complete |
52 | Repair and maintance of existing 150 mm Sluice valve set replacing of brass square bar of size 65mmx65mmx65mm, SS shafting 75mm dia and height of stem 460mm( checknut with shaft), MS bolt nut , Rubber gascut with therading , holes and lath work arrangements including all cost of material and labour charges etc complete |
53 | Repair and maintance of existing 150 mm Sluice valve set replacing of brass square bar of size 65mmx60mmx65mm, ( checknut ), MS bolt nut , Rubber gascut with therading , holes and lath work arrangements including all cost of material and labour charges etc complete |
54 | Repair and maintance of existing 200 mm Sluice valve set replacing of brass square bar of size 65mmx65mmx65mm, SS shafting 75mm dia and height of stem 500mm( checknut with shaft), MS bolt nut , Rubber gascut with therading , holes and lath work arrangements including all cost of material and labour charges etc complete |
55 | Repair and maintance of existing 200 mm Sluice valve set replacing of brass square bar of size 65mmx65mmx65mm, ( checknut ), MS bolt nut , Rubber gascut with therading , holes and lath work arrangements including all cost of material and labour charges etc complete |
56 | Repair and maintance of existing 250 mm Sluice valve set replacing of brass square bar of size 70mmx70mmx70mm, SS shafting 80mm dia and height of stem 560mm( checknut with shaft), MS bolt nut , Rubber gascut with therading , holes and lath work arrangements including all cost of material and labour charges etc complete |
57 | Repair and maintance of existing 250 mm Sluice valve set replacing of brass square bar of size 70mmx70mmx70mm, ( checknut ), MS bolt nut , Rubber gascut with therading , holes and lath work arrangements including all cost of material and labour charges etc complete |
58 | Repair and maintance of existing 300 mm Sluice valve set replacing of brass square bar of size 75mmx75mmx75mm, SS shafting 80mm dia and height of stem 600mm( checknut with shaft), MS bolt nut , Rubber gascut with therading , holes and lath work arrangements including all cost of material and labour charges etc complete |
59 | Repair and maintance of existing 300 mm Sluice valve set replacing of brass square bar of size 75mmx75mmx75mm,( checknut ), MS bolt nut , Rubber gascut with therading , holes and lath work arrangements including all cost of material and labour charges etc complete |
60 | Repair and maintance of existing 350 mm Sluice valve set replacing of brass square bar of size 80mmx80mmx80mm, SS shafting 85mm dia and height of stem 660mm( checknut with shaft), MS bolt nut , Rubber gascut with therading , holes and lath work arrangements including all cost of material and labour charges etc complete |
61 | Repair and maintance of existing 350 mm Sluice valve set replacing of brass square bar of size 80mmx80mmx80mm, ( checknut ), MS bolt nut , Rubber gascut with therading , holes and lath work arrangements including all cost of material and labour charges etc complete |
62 | Repair and maintance of existing 400 mm Sluice valve set replacing of brass square bar of size 80mmx80mmx80mm, SS shafting 85mm dia and height of stem 720mm( checknut with shaft), MS bolt nut , Rubber gascut with therading , holes and lath work arrangements including all cost of material and labour charges etc complete |
63 | Repair and maintance of existing 400 mm Sluice valve set replacing of brass square bar of size 80mmx80mmx80mm, ( checknut ), MS bolt nut , Rubber gascut with therading , holes and lath work arrangements including all cost of material and labour charges etc complete |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy