Agriculture Government Departments Closing in 0 days TDR #35681179

Tender For Construction Of Conference Hall And Aae Room At Adh Office, Kendrapara

Issued by Government Departments · nilagiri, Odisha
Tender Value
23.10 Lakhs
Estimated cost
Bid Submission
20 Jan 2023
0 days left
EMD
23101
Bank guarantee accepted
Document Fee
6000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
nilagiri → Odisha
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Construction Of Conference Hall And Aae Room At Adh Office, Kendrapara Civil Works

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 17-Jan-2023 CORRIGENDUM Technical Bid 20-Jan-2023

BOQ

Name of Work: Construction of Conference Hall & AAE Room at ADH office, Kendrapada
Sl. No. Item Description
1Dismantling and removing R.C.C. columns, beams, slab, staircase landing, lintels including stacking the useful materials for reuse and removing the debris within 50 m lead.
2I. First Floor
3Dismantling brick or stone masonry in lime or cement mortar under 3 m height including stacking the useful materials for reuse and removing the debris within 50 m lead.
4I. First Floor
5Dismantling and removing doors, windows and ventilators including removal of frame, hinges, fastening and stacking the same for reuse and removing the debris within 50 m lead.
6I. First Floor
7R.C.C. work of M-20 grade with 20 mm and down grade black hard granite (Crusher Broken) stone chips including hoisting and laying.
8Column
9I. First Floor
10II. Second Floor
11Beam
12I. First Floor
13II. Second Floor
14Lintel
15I. First Floor
16II. Second Floor
17Stair Case
18I. First Floor
19Roof & Landing
20I. First Floor
21II. Second Floor
22Chhajja
23I. First Floor
24Shelves
25I. First Floor
26Supplying, fitting and placing uncoated HYSD bar reinforcement complete as per drawing and technical specification.
27I. First Floor
28II. Second Floor
29Brick work with fly ash brick having crushing strength not less than 75 Kg/cm2 with dimensional tolerance ±8 percent in cement mortar (1:6) in superstructure.
30I. First Floor
31II. Second Floor
32Filling in foundation and plinth with sand watered and rammed.
33Supplying, fitting and fixing up window (sliding type) made up aluminium section 9778 as windows frame, section No. 4095, 4096 and 9777, 3994 as shutter frame with 5 mm thick black glass as panel fitted with rubber beading including locking arrangment, cost of materials, taxes, labour etc. complete.
34Iron work wrought and put up in window grating including drilling holes in choukathas.
35Fitting and fixing doors and windows with A.I., M.S. sheet, fittings, cleats, hinges, etc. including welding, transportation, labour charges for fitting, etc.
36Cement concrete (1:3:6) with 4 cm size hard granite metal per 1 cum.
37I. First Floor
38Supplying, fitting and fixing vitrified tile (Coloured) of size 600 mm x 600 mm of approved make conforming to IS: 13755 laid on 20 mm thick C.M. (1:4) and filling joints with white cement of approved quality including cost of all materials, labour, etc complete.
39I. First Floor
40Supplying, fitting and fixing ceramic tile (floor) of size 300 mm x 300 mm of approved make conforming to IS: 13755 laid on 20 mm thick C.M. (1:4) and filling joints with white cement of approved quality including cost of all materials, labour, etc complete.
41I. First Floor
42Supplying, fitting and fixing ceramic tile (wall) of size 300 mm x 300 mm in dadoo, skirting and risers of steps on 12 mm thick cement plaster in C.M. (1:3) jointed with neat cement slurry to match the shades of the tiles including rubbing and polishing, cost of all materials, labour, etc complete.
43I. First Floor
44Supplying, fitting and fixing vitrified tile (Coloured) of size 600 mm x 600 mm in dadoo, skirting and risers of steps on 12 mm thick cement plaster in C.M. (1:3) jointed with neat cement slurry to match the shades of the tiles including rubbing and polishing, cost of all materials, labour, etc complete.
45I. First Floor
46Supplying, fitting and fixing chequered tiles in floors tread or steps and landing on 25 mm thick bed of cement mortar 1:1 jointed with neat cement slurry with pigment to match the shades of the tiles including rubbing and polishing complete.
47I. First Floor
48Supplying, fitting and fixing chequered tiles in dadoo, skirting and risers of steps on 12 mm thick cement plaster in C.M. (1:3) jointed with neat cement slurry to match the shades of the tiles including rubbing and polishing, cost of all materials, labour, etc complete.
49I. First Floor
50Providing, fitting and fixing of false ceiling with 12 mm thick gypsum board, Aluminium anodised T Section No. 3215 with 2\"-0\" centre to centre, L section No. 1705 up to 15 micron on 4 walls to be fixed by means of steel screw and PVC plug and the Aluminium grid 2\"-0\" x 2\"-0\" suspended from ceiling etc. complete.
51Supplying, fitting and fixing of stainless steel of 304 grade in hand railing using 50 mm diameter of 2 mm thick circular pipe with Balustrade of size 32 mm x 32 mm x 2 mm @0.90 m c/c and stainless square pipe bracing of size 32 mm x 32 mm x 2 mm in 3 rows in stair case as per approved design and specification, buffing, polishing, etc. with cost, conveyance, taxes, etc.
522.5 cm thick grading concrete (1:2:2) on roof slab with 6 mm size hard granite chips.
53I. Second Floor
546 mm thick cement plaster (1:4) to RCC surfaces finished smooth including closed deep chiping and slury treatment.
55I. First Floor (Inside)
56II. Second Floor (Inside)
5712 mm thick cement plaster (1:6) for brick work.
58I. First Floor (Outside)
59II. Second Floor (Outside)
6016 mm thick cement plaster (1:6) for brick work.
61I. First Floor (Outside)
62II. Second Floor (Outside)
63Priming one coat with any approved primer on new steel surface.
64I. First Floor (Outside)
65II. Second Floor (Outside)
66Painting two coats with any approved paint on new/old wood/steel surface.
67I. First Floor (Outside)
68II. Second Floor (Outside)
69Finishing surface of walls with cement based wall putty (water based) of approved make and finished smooth and even surface to receive painting including cost of scaffolding staging charges with cost of all materials, taxes, labour, etc complete.
70I. First Floor (Inside)
71Priming one coat with any approved primer on plastered surface.
72I. Ground Floor (Outside)
73II. First Floor (Inside)
74III. First Floor (Outside)
75IV. Second Floor (Inside)
76V. Second Floor (Outside)
77Wall painting 2 coats with plastic emulsion paint of approved shade on new work to give an even shade.
78I. First Floor (Inside)
79II. Second Floor (Inside)
80Wall painting 2 coats with weather coat of approved shade on new work to give an even shade..
81I. Ground Floor (Outside)
82II. First Floor (Outside)
83III. Second Floor (Outside)
84Providing and fixing in wall lining with 19 mm thick BWR ply wood of approved make and quality including cost of all materials, cost of labour, conveyance, screws, nails, etc. all complete.
85Providing and fixing of 32 mm thick flush door shutters made out of BWR Block Board of approved make and quality including cost of materials, labour, conveyance, etc. all complete but excluding the cost of hardware fittings.
86Dressed seasoned sal wood work framed and fixed (wrought and put up) in trusses, purlins, frames of doors, windows, ventillators and beams.
87Providing and fixing of 1.5 mm thick high pressure laminated sheet of plain/wood grain in gloss/matte/suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS: 2046 Type S including cost of adhesive of approved quality, cost of materials, labour, conveyance, etc. all complete.
88Providing and fixing Fiber Glass Reinforced Plastic (FRP) door frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.
89Providing and fixing on existing door frames 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire-retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS:14856, including fixing to frames.
90Providing and fixing of hardware fittings of approved make and quality to door shutters including cost of all materials, labour, conveyance, taxes, loading, unloading, etc. all complete.
91MS Butt Hinges (125 x 63 x 4 mm)
92MS Aldrop (250 mm)
93MS Handle (150 mm)
94MS Tower Bolt (150 x 10 mm)
95Hydraulic Door Closers (60 kg)
96Recessed wiring to light point/fan point/exhaust fan point/call bell point with 1.5 sq. mm FR PVC insulated single core multistrand copper conductor ISI marked with 5 Amp, 250 V modular type switch ISI marked and ceiling rose ISI marked mounted on modular G.I. box with modular base and cover of suitable size, MS box with 1.5 sq. mm FR PVC insulated copper conductor single core multistrand copper conductor as earth wire including all accessories and connection as per direction of the Engineer-in-charge. (Make of wire - Finolex/L&T/ Anchor/Havells/VGuard)
97Group-A
98Group-B
99Group-C
100Supplying and fixing of 5/6 amp one way modular type switch on existing switch box/cover including connections etc as required.
101Supplying and fixing of 5 pin 5/6 amp socket outlet modular type on existing switch box/cover including connections etc as required.
102Supplying and fixing of 15/16 amp one way modular type switch on existing switch box/cover including connections etc as required.
103Supplying and fixing of 6 pin 15/16 amp one way modular socket outlet piano type on existing box/cover including connections etc as required.
104Supplying and fixing batten holder/BK angle holder ISI marked including connection etc. as required.
105Installation, testing and commissioning of pre-wired flourescent/compact flourescent fitting of all sizes complete with all accessories and tube etc. directly on ceiling fan, including connection with 1.5 sq. mm FR PVC insulated single core multistrand copper conductor and earthing as required.
106Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FR PVC insulated single core multistrand copper conductor etc. as required.
107Installation, testing and commissioning of resistance type ceiling fan regulator, in existing switch box including connection with 1.5 sq. mm FR PVC insulated single core multistrand copper conductor, earthing the regulator as required.
108Installation, testing and commissioning of exhaust fan up to 450 mm sweep in the existing opening, including making the hole to suit the size of the above fan, making good to the damage complete, connection, etc. as required.
109Extra for fixing of louvers/shutters complete with frame for exhaust fan of all sizes.
110Supplying and fixing of modular G.I. box for 4 module 18 SWG on surface/recess with suitable size of phenolic laminated sheet cover in front including cutting the wall and making good the same in case of recessed conduit as required.
111Supplying and fixing of modular G.I. box for 2 module 18 SWG on surface/recess with modular base & cover for 2 module in front including cutting the wall and making good the same in case of recessed conduit as required.
112Supplying and fixing of modular G.I. box for 8 module 18 SWG on surface/recess with modular base & cover for 8 module in front including cutting the wall and making good the same in case of recessed conduit as required.
113Supplying and fixing of modular G.I. box for 12 module 18 SWG on surface/recess with modular base & cover for 12 module in front including cutting the wall and making good the same in case of recessed conduit as required.
114Supplying and fixing of 20 mm PVC conduit along with accessories in recessed wiring including cutting the wall and making good the same in case of recessed conduit as required.
115Supplying and fixing of 25 mm PVC conduit along with accessories in recessed wiring including cutting the wall and making good the same in case of recessed conduit as required.
116Recessed wiring to sub-main in 2 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metallic heavy duty flexible conduit 1.6 mm thick along with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth as required. (Make of wire - Finolex/L&T/Anchor/Havells/VGuard)
117Recessed wiring to sub-main in 2 x 2.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metallic heavy duty flexible conduit 1.6 mm thick along with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth as required. (Make of wire - Finolex/L&T/Anchor/Havells/VGuard)
118Recessed wiring to sub-main in 2 x 4 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metallic heavy duty flexible conduit 1.6 mm thick along with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth as required. (Make of wire - Finolex/L&T/Anchor/Havells/VGuard)
119Recessed wiring to sub-main in 2 x 6 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 25 mm dia non-metallic heavy duty flexible conduit 1.6 mm thick along with 1 x 2.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth as required. (Make of wire - Finolex/L&T/Anchor/Havells/VGuard)
120Supplyijng and fixing of Triple Pole Neutral 5 amp to 32 amp rating 240 V \"B\" miniature circuit breaker suitable for lighting and other loads in the existing MCB DB ISI marked complete with connections testing and commissioning etc. as required.
121Supplyijng and fixing of Triple Pole Neutral 5 amp to 32 amp rating 240 V \"C\" miniature circuit breaker suitable for lighting and other loads in the existing MCB DB ISI marked complete with connections testing and commissioning etc. as required.
122Supply and fixing of three pole and neutral, sheet steel, MCB distribution, 415 V on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bus bar, din bar, detachable gland plate, interconnection, phosphate and powder painted including earthing etc. as required. (But without MCB/RCCB/ISOLATOR)
123Recessed wiring for light/power plug with 2 x 2.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non-metallic heavy duty flexible conduit along with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor for looping earthing as required. (Make of wire - Finolex/L&T/Anchor/Havells/VGuard)
124Recessed wiring for light/power plug with 2 x 4 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked with 20 mm dia non-metallic heavy duty flexible conduit along with 1 x 2.5 sq.mm FR PVC insulated single core multistrand copper conductor for looping earthing as required. (Make of wire - Finolex/L&T/Anchor/Havells/VGuard)
125Supply, installation, testing and commissioning of 100 Amp TPN main switches (IS 13940 Part 3/1993) on exisiting surface/wall mounting and complete with HRC fuse links, interconnections, earthing, etc as required as per the direction of Engineer-in-charge. (Make - SEIMENS/HPL/ ANCHOR/ L&T/HAVELLS/C&S/RK)
126Supply and fixing of 4 pole MCCB 100 A, 16 KA breaking capacity in exisiting cubicle panel board including drilling holes in cubicle panel, making connections, etc as required.
127Earthing with copper earth plate 600 mm x 600 mm x 3.15 mm thick ISI marked including accessories and providing masonary with cover plate having locking arrangement and watering pipe, etc. (But without charcoal and salt) as required.
128Extra for using salt and charcoal for G.I. or copper plate earth as required.
129Providing and fixing 25 mm x 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode as required.
130Providing and fixing 8 SWG (4 mm) dia copper wire on surface or in recess for loop earthing as required.
131Providing, laying and fixing of one number of PVC insulated and PVC seathed/XLPE power cable (10 sq. mm 4 core PVC armoured cables ISI marked) of 1.1 KV grade of size not exceeding 25 sq. mm on surface as required.
132Providing and fixing on wall face unplasticised rigid PVC soil, waste and rain water pipes conforming to IS: 13592 type A, including jointing with seal ring conforming to IS: 5382, leaving 10 mm gap for thermal expansion.
13375 mm dia
134110 mm dia
135Providing and fixing on wall face 110 mm dia unplasticised rigid PVC moulded fittings/accessories for UPVC rain water pipes conforming to IS: 13592 type A, including jointing with seal ring conforming to IS: 5382, leaving 10 mm gap for thermal expansion.
13675 mm dia
137A. Coupler
138B. Single Tee with Door
139C. Bend 87.50 degree
140D. Vent Cowl
141110 mm dia
142A. Coupler
143B. Single Tee with Door
144C. Bend 87.50 degree
145D. Vent Cowl
146E. Jalli
147F. Water Closet Connector
148Providing and fixing to wall or ceiling and floor pvc pipes class conforming to ASTM-D-1785/89 (Sch-80) and pipe fittings of nominal bore with clamps including making good the wall, ceiling and floor all complete as per specification complete.
14915 mm dia
15020 mm dia
15125 mm dia
152Fixing of 15 mm CP pillar cock with swinging spout capstan head screw down high pressure lettered \"Hot\" and \"Cold\" with long screws, shanks and back nuts as per specification complete.
153Fixing of CP long nose bib cock polished bright conforming to IS: 781-1995 as per specification complete.
154Fixing of other bathroom accessories as per specification complete.
155CP Flange (Big)
1562\" CP Extension Piece
15715 mm dia CP Grating
158Fixing15 mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin as per specification complete.
159Fixing of 15 mm CP angular stop cock conforming to IS:781-1995 of 15 mm dia nominal sizes as per specification complete.
160Fixing water closet, squatting pan (Indian type WC pan) conforming to IS 2556: Part 3 - 2004 duly embedded in cement concrete (1:4:8) using hard granite metal 4 cm nominal size as per specification complete.
161Fixing wash down water closet (European type WC) with integral \"S\" or \"P\" trap conforming to IS: 2556 : Part 8-2004 to the floor with wooden plug and CP screws including jointing the trap with soil pipe in cement mortar (1:1) as per specification complete.
162Fixing plastic seat and cover for wash down water closet with CP brass hinges and rubber buffers as per specification complete.
163Fixing Porcelain Flat Back Stall Type Magnum Urinal bowl pattern urinal conforming to IS 2556: Part 6 - 1996 including connecting the urinal of size with waste pipe by means of white lead mixed with chopped hemp as per specification complete.
164Fixing glazed earthernware squatting plate of size 600 mm x 350 mm conforming to IS 2556: Part 6 - 1995 with integral longitudinal flushing pipe including embedding the plate in 25 mm cement mortar (1:8) laid over 150 mm cement concrete (1:4:8) using 40 mm hard granite metal as per specification complete.
165Providing and fixing PVC low level flushing cistern with manually controlled device (hand lever) conforming to IS: 7231 with all fittings and fixtures complete.
166Fixing wash basins with hole for pillar taps conforming to IS: 2556: Part 4-2005 with cast iron or MS brackets painted white including cutting holes in walls and making good to the damages etccomplete as per specifications.
167Fixing PVC waste pipe of flexible (coil shaped) PVC waste pipeof 32 mm nominal dia with length not less than 700 mm with PVC fittings for wash basin or sink including brass check nut complete as per specification.
168Fixing CP brass waste of 32 mm diameter for wash basin or sink including brass check nut complete as per specification.
169Fixing CP brass shower rose with 15 mm or 20 mm inlet including polishing complete as per specification.
170Fixing 600 mm x 450 mm bevelled edge mirror of superior glass mounted on 6 mm thick A.C. sheet or plywood sheet and fixed to wooden plugs with CP brass screws and washers complete as per specification.
171Fixing standard sized glass-shelf with CP brass brackets and guard rails complete, fixed to wooden plugs with CP brass screws and washers complete as per specification.
172Fixing standard sized CP brass towel rail complete with CP brass brackets fixed to wooden plugs with CP brass screws as per specification.
173Fixing standard sized CP brass towel ring complete with CP brass brackets fixed to wooden plugs with CP brass screws as per specification.
174Fixing CP brass soap dish complete with CP brass brackets fixed to wooden plugs with CP brass screws as per specification.
175Fixing liquid soap container complete with CP brass lid and brackets fixed to wooden plugs with CP brass screws as per specification.
176Cutting holes through existing brick work (250 mm thick wall) including making good the same in cement mortar (1:4) for taking GI/PVC pipes and fittings etc all complete as per specification.
177Cutting grooves in pucca floors and walls for taking GI/PVC pipes and making good the damages complete as per specification.
178Providing and fixing granite stone of approved shade with table rubbed, edges rounded and polished of size 75 x 50 cm deep and 1.80 cm thick, fixed in urinal partitions by cutting a chase of appropiate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete (1:2:4) as per the direction of Engineer-in-charge and finished smooth.

AI Tender Summary

OUR REF NO 35681179
AUTHORITY Government Departments
TENDER VALUE 23.10 Lakhs
LAST DATE 20-01-2023
Authority
Authority Name Department Of Horticulture
Work Description Construction Of Conference Hall And Aae Room At Adh Office, Kendrapara Civil Works
Basic Detail
Tender No E.E- DH (O) -01 of 2022-23
Bidding Type Tender
Location
City nilagiri
State Odisha
Key Dates
Publish Date 17 Jan 2023
Submission Date 20 Jan 2023
Open Date 25 Jan 2023
Finance
Tender Value 23.10 Lakhs
Tender Fee 6000
EMD 23101
Exemption Not Available
Document List
06224683-a5c1-46f6-bf5e-eede1ad002e4.html
BOQ_424441.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jan 17, 2023
11:30 IST

Tender Published

Tender notice published.

Completed
Jan 20, 2023
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jan 20, 2023
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jan 25, 2023

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

06224683-a5c1-46f6-bf5e-eede1ad002e4.html

xls

BOQ_424441.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders