Department Of Agriculture-DOA has published Tender For Operation Running Maintenance And Rep In C Requrmnt Of Spare Parts Of Plant And Machinery Of 2000 Mt Capacity At Baikhora Cold Storage In C Preoperative Servicing Mtc Of P And M As Well As Preoperative Post Shutdown Cleaning Of Condenser . Submission Date for this Tender is 24-01-2023. Spare Part Tenders in Baikhora Tripura. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Baikhora Cold Storage |
2 | Providing of un-skilled worker(cleaner) for pre-operative & post shut-down cleaning of condenser tank, condenser, in & around cold store chamber, stair case, drying shed & plant room during the season:-2020 as per direction of Engineer- in-charge. |
3 | Servicing of Kirloskar make 3(three) phase squirrel case 25H.PInduction Motor having Star-Delta operating system as well as squirrel case 30 H.P Induction Motor having variable resistance operating system after disconnecting & dismantling with checking of bearing, replacement of bearing if required, checking of insulation resistance of stator & rotor winding, heat and varnishingincluding re-assembling, re-positioning & re-connection, commissioning complete as per direction of Engineer- in-charge (Unit No. – I ) |
4 | Servicing of KIRLOSKER make 5 H.P, 3 phase electric power operated water pump(mono-set) after disconnection, dismantling with checking of bearing, greasing in bearing replacement of bearing if required, checking of insulation resistance of winding, heat varnishing if required, replacement of gland packing re-assembling, re-positioning, re-connection, commissioning complete as per direction of Engg-in charge |
5 | Servicing of Ashoke Leyland make Diesel Engine coupled with Kirlosker make alternator 110 KVA ,3phase, A.C, Diesel Generator set after dismantling with checking of tappet clearance, adjustment of tappet clearance if required, cleaning of crank case, diesel tank, air-cleaner, re-filling of engine oil in crank case,replacement of diesel filter & engine oil filter re-assembling commissioning complete as per direction of Engg-in-charge |
6 | Removal of damaged M.S Pipe & M.S bend ( Heavy Duty) having 50 mm dia and 4.58 mm thickness ( used for refrigerant Condenser using ammonia as refrigerant to withstand pressure upto 240 PSI) from existing Condenser coil by cutting with Oxyacetyline flame in all respect as per direction of the Engg-in- Charge. |
7 | Providing of Compressor oilbrand Name Servo (FRIZ 68) or equivalent for use of the Baikhora Cold Storage. Including carrying loading and unloading from Kolkata. |
8 | Providing & supply of Anhydrous Ammonia Gas cylinder as required for smooth running of2000M.T capacity Cold Storage at Baikhoraduring the season 2020, ( as per requirement) |
9 | Providing and fittings fixing of heavy duty 10(Ten) Nos MS pipe and 05 (Five) Nos MS bend of 50 mm and 4.85mm thickness ( used for refrigerant Condenser using ammonia as refrigerant to withstand pressure upto 240 PSI) of ISI Marked , TATA make or equivalents in proper position for condenser coil with necessary Arc welding including trial run complete in all respect as per direction of Engg-in-Charge. |
10 | Arrangement for operation of 2000 M.T capacity Cold Storage including Captive Power Plant with day to day maintenance and repairing during the stipulated period with supplying of Super skilled worker Mechanic cum Electrician cum Operator as well as Helper/Assistant for proper and smooth running of the Cold Storage, Baikhora through round the clock of 24 Hours in 03(three) Shifts as per direction of Engg-in-charge. |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy