Public Administrative Department Local Bodies Closing in 0 days TDR #35670051

Tender For Miscellaneous Works For Upgradation Of Upgraded Middle School Sarwaha Churchu Hazaribag

Issued by Local Bodies · churchu, Jharkhand
Tender Value
1.28 Crore
Estimated cost
Bid Submission
26 Jan 2023
0 days left
EMD
2.58 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
churchu → Jharkhand
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Miscellaneous Works For Upgradation Of Upgraded Middle School Sarwaha Churchu Hazaribag

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 18-Jan-2023 Date Extend Date 26-Jan-2023

BOQ

Name of Work: Miscellaneous works for upgradation of Upgraded Middle School, Sarwaha, Churchu, Hazaribagh
Sl. No. Item Description
1Earth work in excavation in foundation trenches in ordinary soil ( vide classification of soil itemA) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction of E/I.
2Extra for earth work in hard soil as per specification and direction of E/I. (vide classfication of soil item - B)
3Earth filling in foundation trenches and plinth in layers not exceeding 150 mm. thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation frenches within a lead of 50 M. and lift of 1.5 M all complete as per building specification and direction of E/l (Mode of measurement compacted volume).
4Filling in foundation trenches and plinth in layers not exceeding 150mm thick well watered, rammed fully compacted and fine dressed with earth obtained after cutting within a lead of 50M and lift of 1.5M all complete as per building specification and direction of E/I. (Mode measurement compacted Volume).
5Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including\" cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/l (Mode of measurement compacted volume).
6Providing designation 75 B brick work in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10 mm thick mortar joints, cost of screening materials, raking out joints to 15 mm depth, curing, taxes and royalty all complete as per building specification and direction of E/l.
7Providing designation 75 B brick work in C.M. (1:6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including, providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/I.
8Providing designation 125 mm thick reinforced designation 75A brick work in CM (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 25 including the cost of screening, carriage of materials, scaffolding , raking out joints to 15mm depth, curing, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specification and direction of E/I.
9Providing designation 100 A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9\"x4.5\"x3\") in C.M. (1:6) in foundation and plinth with approved uality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I.
10Providing designation 112mm thick reinforcement designtion 100 A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9\"x4.5\"x3\") in C.M. (1:4) in supertructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including cost of screening materials scaffoliding raking out joints to 15mm depth curing taxesand royalty ( but excluding theb cost of reinforcement) all complete as per building specification and direction of E/I.
11Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size)
121:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
131:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 40mm nominal size)
141:3:6(1Cement:3coarsesand(zone-III):6gradedstoneaggregate40mm nominal size)
15Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20mm nominal size).
16Making plith protection 50mm thick of cement concrete 1:3:6 (1 Cement : 3 coase sand ( zone-III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth
17Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - all work up to Plinth Level- 1:1.5:3 (1 cement ; 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20mm nominal size)
18Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string course, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reionforcement :(1:1.5:3 (1 cement : 1.5 : coarse sand (zone-III) : 3 graded stone aggregate 20mm nominal size)
19Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15\" landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20mm nominal size).
20Centering and shuttering including strutting, propping etc. and removal of form for Foundations, fotting, bases of columns, etc. for mass concrete
21Suspended Floors, roofs, landings, balconies and access platform
22Lintels, beams, Plinth beams, girders, bressumers and cantilevers
23Column, Pillars, Piers, Abutments, Posts and struts
24Stairs, (excluding landings) except spiral-staircases
25Weather shade, Chajjas, corbels etc. including edges
26Providing Toe steel reinforcement of following dia rods as approved design and drawing excluding carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (Only Valid for SAIL, TATA Steel, JSPL, Electro Steel Ltd. and Vizal Steel)8mm
2710mm
2812mm to 25mm
29S/F M.S. grill made of 20 x 6mm M.S. flat as per approved design and drawing, properly fabricated with joints continous fillet welded and finished smooth, carriage of grill to work site, hoisting as per building specification and direction ofE/I. (Where materials is not supplied by the deptt.)
30Providing designation 75 B one brick flat soling joints filled with local sand including cost of watering texes royalty all complete as per building specification and direction of E/I.
31Providing 25mm thick first class patent stone flooring (1:2:4) with stone chips in two layers, bottom layer 19mm thick (1:2:4) with 12mm to 6mm size graded stone chips and top layer 6mm thick (1:2) with 6mm down stone chips, in panels including cost of curing, finishing the surface smooth by rubbing with carborandum stone, taxes and royalty with all complete as per building specification and direction of E/I.
32Providing 12mm cement mortar (1:3) with clean coarse sand of F.M. 1.5 with floating coat of neat cement in skirting including rounding of junctions with floor, curing, taxes and royalty all complete as per building specification and direction of E/I.
33Extra for providing and fixing 30X4mm glass strips in joints of flooring , complete job as per specification and direction of E/I.
34Providing and laying vitrified paring/industrial tiles in different sizes (thickness to be specified by the manufacture ) with water absorption less than 0.08% and confirming to IS : 4457:2007, of approved make, in all colour and shades, laid on 20mm thick cement mortor 1:4 (1 cement : 4 coarse sand ), jointing with grey cement slurry @ 3.3Kg/Sqm including grouting the joint white cement and matching pigment etc, complete Size of tile 300x300x10 mm size.
35Providing 12mm cement plaster (1:3) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I.
36Providing 12mm thick cement plaster (1:4) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I.
37Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I.
38Providing 6mm thick cement plaster (1:4) in ceiling with clean of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
39Providing 1.5mm cement punning including curing, carriage of water with all leads and lifts as per building specification and direction of E/I.
40Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by rubbing smooth with pumice stone or fine sand paper, applying putty wherever required, scaffolding, washing of floors and taxes all complete as per building specification and direction of E/l.
41Providing two coats of snowcem of approved shade and make over a coat of cement primer on new surface including preparing the plastered surface smooth with sand paper, scaffolding, curing and taxes all complete as per building specification and direction of E/I.
42Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dust, dirt, scales smokes and grease and cleaning the surface thoroughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I. (Mode of measurement Area shall be multiplied by the co-efficient as indicated in building specificatio).
43Providing two coats of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface thoroughly cost of scaffolding and taxes all complete as per building specification and direction of E/I.
44Dismantling pucca brick or lime work including stacking serviceable materials in countable stacks within 15M. lead and disposal of unserviceable materials with all leads all complete as per direction of E/l.
45Dismantling plain cement or lime concrete work including stacking serviceable materials in countable stacks within 15M. lead and disposal of unserviceable materials with all leads all complete as per direction of E/l.
46Dismantling R.C.C.work including stacking serviceable materials in countable stacks within 15M. lead and disposal of unserviceable materials with all leads all complete as per direction of E/l.
47Dismantling patent stone floor including stacking serviceable materials in countable stacks within 15M. lead and disposal of unserviceable materials with all leads all complete as per direction of E/l.
48Dsimantling old plaster and pointing in cement or lime and raking out joints to 15mm depth watering and disposal of unserviceable materials with all leads all complete as per direction of E/I.
49Taking down old door and window shutters including stacking serviceable materials with all leads all complete as per direction of E/I.
50Taking down chaukhats in doors including stacking serviceable materials with all leads all complete as per direction of E/I.
51Taking down chaukhats in windows including stacking serviceable materials with all leads all complete as per direction of E/I.
52Providing 150mm. Wide brick drain in cement mortar (1:6) with av. 150mm clear depth and 125mm apron including cost of eartwork involved with 75mm cement concrete (1:4:3) over one brick designation 75A flat soling in proper grade and slope at the base the drain duly plastered in C.M. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I.
53Water proofing for old and New Roof Slab : - Providing and laying water proofing treatment on roof slab by applying two Component, factory designed, ready to use, acrylic modified flexible material applied with brush, roller or spray for water proofing coating as per manufacturer specifications with following steps:-Surface preparation :- Providing and cleaning of concrete surface to remove dust, oil, grease including removal of existing loose paint/coating and cement laitance by cleaning with compressed air & water jet including all materials, labour, tools complete Ponding test to be done after plugging all outlets and to be checked from soffit to identify seepage, leakage. On identification of seepage, cement grouting to be done with non shrink expanding admixture of Sika India Pvt. Ltd/MYK schomberg/Dr. Fixit/fosroc or equivalent. Proiding and reparing of all corners and joints such as those between the parapet wall and the roof slab etc. shall be chamfered with 150mm x 150mm fillet of mortar (Cement sna - 1:4) admixed with acrylic polymer of Sika/Fosroc/MYK Schomberg/Dr. Fixit or equivalent. Before chamfering surface irregularities, damaged concretein base slab, dead cracks if any, with an acrylic polymer modified repair mortar including a coat of bonding agent of the same with cement slurry including all material, labour, tools complete.1st coat :- Apply 1st coat of two component acrylic modified, ready to use, flexible cementitious material on surface saturated dry roof and inside wall of Parapet wall upto 600mm by brush or roller. After 1st coat of application, 45 gsm of fibre glass cloth to lay when the first layer is still green, 1st coat should be applied @ 1.50 kg/sqm/coat. For the purpose of measurement the entire treated surface will be measured.2nd Coat :- To apply the 2nd coat of two component acrylic modified, ready to use, flexible cementitious material right angle to the 1st coat over the glass fibre laid surface. 2nd coat should be applied @ 0.7 kg/Sqmt/coat. For the purpose of measurement the entire treated surface will be measured. After three days of drying the 2nd coat, the rain water outlets to be plugged and ponding test to be done for 48 hours to identify seepage, leakage from soffit and if found necessary rectification to be doen as per satisfaction of E/C. The waterproof coating to be protected from damage before screed over it. Water proofing coating to be protected from damage before screed over it. Water proofing Brand-Sika Topseal 109hi/Fosroc Brushbond RFX/Dr Fixit Pidifin 2K/MYK Auafin TG, Product Performance - chemical Base part A : Acrylic copolymer, Part B : Specially graded cementtitious powder - Density 1.6 kg/l (mixed density) at +270C Tensile strength ~ 2N/mm2 after 28 days (with Fibre cloth) (according to ASTM D 2370) Pullout Bond Strength ~ 2 N/mm2 (concrete failure) (According to ISO 4624) Slant-shear bond strength~4 N/mm2 (According to FIP 5.15) Elongation at Break ~ 35% without Fibre Cloth and 20% with fibre cloth (According to ASTM D 2370)Protection of treatedsurface with PCC : - The treated surface should be covered with 25mm/50mm PCC of M-20 grade (1:1.:3) with proper slope (1:120) towards the rain outlets in alternatepanels of 2 Mt x 2mt keeping 6mm gap between the panel joint intergal water proofing admixture conforming to IS 2645 @ of 100 ml per bag of cement to be added in the acreed concrete (paid separately for this items) all corners shall be chamfered with 150mm x 150mm fillet. The rainwater outlets shall be just leveled with the screed concrete to ensure smooth discharge of water - the peripheral gaps between PVC pipe outlet and concerte surface should be packed properly with rich concrete and the peripheral mouth to be sealed with moisture insentive epoxy putty of Sika India pvt Ltd/MYK Schomberg/Dr. Fixit/Fosroc. For the purpose of measurement the entire treated surface will be measured.\"Groove of PCC surface should be filled with Polysulphide Sealant. (Paid Separately) Brand - Sika India Pvt. Ltd./MYK Schomberg/Dr. Fixit/Fosroc. Warantly for five years.
54Covering of treated surface with PCC : Providing 25mm thick cement concrete M-20 (1:1.5:3) maintaining slope in alternate 2mt x 2 mt panels with approved quality of stone chips of 20mm to 6mm size graded and cleaned sand of F.M. 2.5 to 3 including screening, shuttering and mixing cement concrete in mixer with admixture of integral water proffing and placing in position, skirting curing, taxes and royalty all complete as per building specification and direction of E/I. Panels that has been left should be casted next day. there should be 6mm gap between Panels Brand-Sika-Plastocrate plus, MYK proof WP 10, Fosroc-Conplast X421 ic Dr. Fixit Pidiproof LW+
55Providing 19mm thick water proof cement plaster (1:3) with clean coasre sand of F.M. 1.5 with integral water proofing compound Liquid @ 125ml per bag cement including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. Brand-Sika-Plastocrate plus, MYK proof WP 10, Fosroc-Conplast X4211C, Dr. Fixit Pidiproof LW+ or Equivalent
56Providing and filling of 6mm thick Groove between 25mm PCC Panels with Polysulphide Sealant (Poring Grade) as per drawings and technical specifications and direction of E/I. (with 18% GST) Brand - Sika-Polysulphide, Forsoc-thioflex 600, Dr. Fixit Pidiseal PS (42P, MYK Seal PS or Equivalent.
57Jungle cleaningClearing jungle including uprooting of rank vegetation, grass, brush wood,trees and saplings of girth up to 30 cm measured at a height of 1 mabove ground level and removal of rubbish up to a distance of 50 moutside the periphery of the area cleared.
58Providing and fixing Ist quality ceramic glazed wall tiles conforming toIS: 15622 (thickness to be specified by the manufacturer), of approvedmake, in all colours, shades except burgundy, bottle green, black ofany size as approved by Engineer-in-Charge, in skirting, risers of stepsand dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm,including pointing in white cement mixed with pigment of matching shadecomplete.
59Providing and fixing 1mm thick M.S. sheet door & windowwith frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S. angels 40x40x6 mm for diagonal braces
60Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes
61Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
62Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets,gates and similar works
63Providing and fixing angle iron frames for doors, windows and ventilatorsof mild steel Angle sections of size 35x35x5 mm, joints mitred andwelded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existingT-iron frame or to the wall with dash fastener,including fixing of necessarybutt hinges and screws and applying a priming coat of approved steelprimer, all complete as per the direction of Engineer-In-charge.
64Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :25 mm thick
65Providing and fixing on wall face unplasticied Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10mm gap for thermal expansion (i) Single socketed pipes.75 mm
66110 mm
67Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Single tee with door - 75x75x75 mm
68Single tee with door - 110x110x110 mm
69Single tee without door - 75x75x75 mm
70Single tee without door - 110x110x110 mm
71Bend 87.5° - 75mm
72Bend 87.5° - 110mm
73Providing and fixing precoated galvanised iron profile sheets (size,shape and pitch of corrugation as approved by Engineer-in-charge)0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 micronsepoxy primer on both side of the sheet and polyester top coat 15-18microns. Sheet should have protective guard film of 25 micronsminimum to avoid scratches during transportation and should besupplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tappingscrews of size (5.5x 55 mm) with EPDM seal, complete upto anypitch in horizontal/ vertical or curved surfaces, excluding the cost ofpurlins, rafters and trusses and including cutting to size and shapewherever required.
74Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :Ridges plain (500 - 600mm)
75Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/10 sqmover and including priming coat of exterior primer applied@ 2.20 kg/10 sqm)
76Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
77Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratchesetc. complete
78Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/ 5cm. Tear strength in longitudinal and transverse direction as 300/ 250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick
79Extra for covering top of membrane with Geotextile, 120 gsm nonwoven, 100% polyester of thickness 1 to 1.25 mm bonded to themembrane with intermittent touch by heating the membrane by ButaneTorch as per manufactures recommendation.
80Providing and laying factory made chamfered edge Cement Concrete paver blocks In foot path, park & lawns driveway or light & traffic parking etc. of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of course sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, all complete as per manufacturer\"s specifications & direction of Engineer- in-Charge.60mm thick Cement concrete paver block of M-30 gradewith approvedcolour, design & pattern.
8180mm thick Cement concrete paver block of M-30 gradewith approvedcolour, design & pattern.
82Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type orof approved makeincluding tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge50 mm Avrage Thickness
8325 mm Avrage Thickness
84Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust freesteel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge.Bars upto 12 mm diameter
85Bars above 12 mm diameter
86Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used)as per specifications and directions of Engineer-in-charge.25 mm average thickness in 2 layers.
87Providing, mixing and applying SBR polymer (of approved make @ minimum 2% by wt. of cement used) modified plain/reinforced cement concrete for structural members havingminimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10mm maximum size in proportion as per design criteria] with specified average thickness.Note: Rates shall be for finished surface area of concrete and shall include the cost of labour, concrete and appropriate approved Super- Plasticiser for rendering concrete as flowable and SBR polymer but shall exclude cost of reinforcement, bond coat, Shear Keys, centering and shuttering, strutting, propping etc (Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/tapping with a blunt metal instrument)50mm thick in Grade M 25 with cement content not lessthan 330 kg per cum
88Caraige of materialsBricks Lead = 8km (7p+1k)
89Sand lead = 10 km
90Stone chips lead = 22 km
91Stone metal lead = 22 km
92Cement - Lead 10km
93Steel - Lead 10km
94Fly Ash Lead - 15km
95Paver Block - 15km
96Carrage of Earth - Lead 3km
97Disposal of building rubbish - Carraige of Earth - 1Km lead
98Point wiring in PVC consuit, with piano type switch -Wiring for light point/exhaust fan point/call bell point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, with piano type switch, phenolic laminated sheet, suitable size PVC/G.I. box etc. as requiredGroup A
99Group C
100Power plug wiring in PVC conduit (2 x 4 sq. mm) :-Wiring for light/power plug with 2 x 4 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, along with 1 No 4 sq.mm FR PVCinsulated copper conductor single core cable for loop earthing etc as required.
101Circuit/submain wiring in PVC conduit - Wiring for Circuit/submain wiring along with earth wire the following sizes PVC insulated copper conductor, single core cable in surface/recessed PVC conduit as required.2 x 1.5 sq.mm + 1 x 1.5 sq.mm earth wire
1022x2.5 Sqmm + 1x2.5 sq mm earth wire
1032x6 Sqmm + 1x6 sq mm earth wire
1042 x 6.0 sq.mm + 1 x 6.0 sq.mm earth wire
105Wiring in existing conduit - Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit as required.3x1.5sq mm
1063x2.5sq mm
107S/F PVC /G.I. boxes - Supplying and fixing PVC/G.I. box of following sizes on surface or in recess with suitable size of phenolic laminated sheet cover infront including painting etc. as required.72mm x 146mm x 48mm deep/(4\" x 7\")
108147mm x 93mm x 47mm deep/(5\" x 7\")
10972mm x 226mm x 48mm deep/(4\" x 10\")
110S/F piano type switch/socket - Supplying and fixing following piano tyep switch/socket on the existing switch box/cover including connections etc. as required.5/6 amps, one way switch
11115/16 amps, one way switch
1123 pin 5/6 amps, socket outlet
1136 pin15/16 amps, socket outlet
114Electronic step fan regulator, mini
115S/F ceiling rose - Supplying and fixing 2 pin 5 amp ceiling rose on the existing junction box/wooden block including connection etc. as required.
116S/F Batten holder - Supplying and fixing batten/angle holder including connection etc. as required.
117ITC fluorescent fitting directly on surface -Installtion, testing and commissioning of Pre-wired, fluorescent fitting/compact fluorescent fitting of all type, complete with all accessories and tube etc. directly on ceiling/wall, including connection with 1.5 sq.mm. FR PVC insulated, copper conduit.
118ITC exhaust fan upto 450mm sweeo - Installation of exhaust fan upto 450mm sweep in the existing opening, including making the hole to suit the size of the above fan, making good the damage, connection, testing commissioning etc. as required.
119S/F rewireable double pole/TP&N switch disconnector - Providing and fixing following capacity double pole/TP&N sheet metal switch disconnector fuse unit in existing metal board with rewireable type fuses, including drilling holes in metal board, making connections, etc as required.32 amps, double pole
120S/F S.P. MCB DB - Supplying and fixing following way single pole netural, sheet, MCB distribution board, 240 volts, on surface/recess, complete with tinned copper busbar, netural busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (But without MCB/RCCB/Isolator)2way, Single door
1218 way, Single door
122S/F \"B\" series, S.P. MCB -Supplying and fixing 6 amps to rating, 240 volts, \"B\" series, miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commossioning etc. as required6/32 amps, single pole \"B\" series
123S/F DP MCB Isolator - Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required40 amps
124Earthing with G.I. earth pipe 4.5 mtr. Long, 40mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal and salt as required
125Supply, Installation, testing and commissioning of following, size ceiling fan 3 Blades confirming to IS : 374 : 2019 including wiring the down rods of standard length (up to 30cm) with 1.5 sq.mm. FR PVC insulated, copper wire suitable for 230V 50Hz, single phase supply etc. complete as required.1200mm (48\") ceiling Fan
126S.I.T.C. of following rating, surface mounted LED light fitting, suitable for 230V 50Hz, single phase supply etc. complete as required.20/22W LED Tube Light
1279/10Watt LED Bulb
12812\" (300mm) metal exhaust fan
12948\" ceiling fan rewinding with ball bearing
13048\" Celing fan blade ( for 20 no ceiling fan)
131Providing and fixing male ended 15mm dia brass bib cock of approved quality (Wt. not less than 350 gms.) with extra socket all complere as per specification and direction of E/I.
132Providing and fixing Gun metal full way valve of approved quality all complete as per specification and direction of E/I.25mm dia
133Making holes in walls for laying G.I. pipes and restoring the same after pipe laying as per specification and direction of E/I.125mm thick wall
134250mm thick wall
135Supplying, fitting and fixing the following items complete with all materials as per specification and direction of E/I.C.P. brass soap dish container medium quality with screw and hinges etc.
136Supplying, fitting and fixing viterous white glazed earthen ware I.W.C. of parry Hindustan or any other I.S.S. approved make with 100mm H.C.I. \"p\" trap 15 litres C.I. pull and let go flushing cistern of names or other I.S.S. equivalent make, complete with all fittings, C.I. or C.C. brackets 32mm alkathene/P.V.C. telescopic flush, pipe about 2M long with one brass coupling and clamps G.I. chain and pull including supplying and fixing a pair of viterous white glazed earthenware footrest to be fixed in floor 15mm C.I. body brass spindle stop cock of weight not less than 50grms, 15mm P.V.C. connection pipe 450mm long and the exposed pipe and cistern with two coats of approved paint over a coat of red oxide primer etc. all complete as per specification and dirction of E/I.580mm long - With 10 liter low level PVC cistern
137Supplying, fitting and fixing flat back or angular, lipped front viterous white glazed earthen ware urinal of Hindustan \"Parry\" or any other approved I.S.S. make with 5 litres capacity C.i. automatic flusing cistern of reliance for any other I.S.S. approved make with all fittings with C.I. or R.S. brackets, standard size G.I. flush pipe with fitting clamps, 15mm C.I. body brass spindle stop cock of approved quality weight not less than 400 grams, 15mm PVC/Alkthene pipe 450mm longwith brass coupling at both ends and doing plumber joints including priming coat of red oxide, cutting wall and floor making good the same etc. all complete as per specification and direction of E/I.Flat back or standard corner (600mm x 350mm)
138Supplying fitting and fixing viterous white glazed earthen ware wash hand basin of parry or Hindustan or any other I.S.S. approved make supported on painted C.I. or R.S. brackets 32mm C.I. brass waste, 15mm dia C.I. body brass spindl stop cock approved quality of weight not less than 30 grams, 32mm P.V.C. waste pipe 750mm long with brass coupling at one end and making plumber joints etc. all complete as per specification and direction of E/I.
139Earth work in excavation for laying of different types and sizes of R.C.C. spun pipes with disposal of exacavted earth within initial lead and sizes of R.C.C. spun pipes with disposal of excavated earth within initial lead and lift as per specification and direction of E/I.For classification of soil item - A
140Lbour for alying, fitting and fixing NP2 R.C.C. spun pipe with colars in lines, level and grade and providing approved jointing materials and joints properly filled to make them leakproof including providing sight rails, bonning rod, night guard, Red light and barrier etc. all complet as per specification and direction of E/I.150mm dia RCC spun pipe - Upto 3.0 metre depth of invert below G.L.
141Supplying materials and labours for constructing inspection chamber of designation class 75B bricks size 750mm deep, 600 x 450mm internal dimension having 250mm wall thickness in cement mortar (1:6) including 12mm cement plaster (1:4) with punning on inside and cement plaster (1:6) with 600 x 475mm G.I. Cover with frame (weight not leaa than 36 kg) alongwith earth work in exacavation and 80mm thick P.C.C. (1:3:6) in foundation and refilling all complete as per specification and direction of E/I.
142Supplying and fixing NP2 Hume pipe etc. (150mm dia)
143Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall25 mm nominal outer dia Pipes
144Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc.15 mm nominal outer dia Pipes
14520 mm nominal outer dia Pipes
146Providing and placing on terrace (at all floor levels) polyethylene waterstorage tank, ISI : 12701 marked, with cover and suitable lockingarrangement and making necessary holes for inlet, outlet and overflowpipes but without fittings and the base support for tank.
147Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.With common burnt clay F.P.S. (non modular) bricks ofclass designation 7.5
148Cost of Drilind 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressure and equipmentsas well as fule, lubricants and cost of transportation of rig machine and other vehical up to Site.(a) From 0.00 M to 50.00 M below G.L.
149(b) From 51.0 M to125.00 M
150(c) From126.0 M to150.00 M
151Supplying, assembling, lowering and fixing in vertical position in borewell,unplasticizedPVCmediumwellcasing(CM)pipeof required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.200 mm nominal size dia
152Development of tube well in accordance with IS : 2800 (part I) andIS: 11189, to establish maximum rate of usable water yield withoutsand content (beyond permissible limit), with required capacity aircompressor, running the compressor for required time till well isfully developed, measuring yield of well by \"V\" notch method or anyother approved method, measuring static level & draw down etc. bystep draw down method, collecting water samples & getting testedin approved laboratory, i/c disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessoriesetc., all as per requirement and direction of Engineer-in-charge
153Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of:200 mm dia
154Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.200 mm clamp
155Supplying Submersible pump sets confirming to IS 8034 and motor confirmingto IS 9283. Pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/noryl impeller. Motor suitable for working on 415V + 10%, 3PH, 50 Hz, A.C. supply with cable guard, thrust carbon/fiber bearing to withstand entire hydraulic thrust, water proof winding shall be provided. the pump set shall be suitable for direct coupling. Pump shall have suitable outlet as per manufacturers design. Anti thrust stream lined non return valve shall be provided with pump. 3 meter submersible copper conductor cable in single/double run shall be provided with each pump.Submersible Pump set 100mm dia (with Polypropylene/Noryl Impeller) up to 20 stages - 2 HP
156Supplying fitting and fixing 3 crore 4 sqmm Flat copper submersible cable FINOLEX / HEVELS make including all taxes ,royalty etcall complete job as per direction of E/I.
157Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.External work - 50 mm nominal dia Pipes
158Supplying Fully automatic star delta starter to operate induction motor working on 415V, 3 phase, 50 hz with no volt coil, Over load element, ON-OFF push buttons, with necessary materials and connected to supply, etc. complete starter with original sheet steel encloser as per IS : 3914
159Goods & Services Tax (G.S.T.) - 18%
160Labour Cess - 1%

AI Tender Summary

OUR REF NO 35670051
AUTHORITY Local Bodies
TENDER VALUE 1.28 Crore
LAST DATE 26-01-2023
Authority
Authority Name Zilla Parishad
Work Description Miscellaneous Works For Upgradation Of Upgraded Middle School Sarwaha Churchu Hazaribag
Basic Detail
Tender No 42/2022-23
Bidding Type Tender
Location
City churchu
State Jharkhand
Key Dates
Publish Date 18 Jan 2023
Submission Date 26 Jan 2023
Open Date 28 Jan 2023
Finance
Tender Value 1.28 Crore
Tender Fee 10000
EMD 2.58 Lakhs
Exemption Not Available
Document List
Termsconditions.pdf
Tendernotice_1.pdf
BOQ_86952.xls
c355e96d-90e0-4463-9c10-5d98dfd59b93.html

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jan 18, 2023
11:30 IST

Tender Published

Tender notice published.

Completed
Jan 26, 2023
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Jan 26, 2023
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jan 28, 2023

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

Termsconditions.pdf

pdf

Tendernotice_1.pdf

xls

BOQ_86952.xls

html

c355e96d-90e0-4463-9c10-5d98dfd59b93.html

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender