Tender For Invitation To Pre-Tender Meet- For Building Works 3 - Admin And Misc. Buildings For Pdh-Pp Project At Gail Usar, Raigad-Maharashtra

Gas Authority Of India Limited has published Tender For Invitation To Pre-Tender Meet- For Building Works 3 - Admin And Misc. Buildings For Pdh-Pp Project At Gail Usar. Submission Date for this Tender is 23-01-2023. Uniform Tenders in Raigad Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

35658776
Corrigendum : Tender For Invitation To Pre-Tender Meet- For Building Works 3 - Admin And Misc. Buildings For Pdh-Pp Project At Gail Usar
Tender
Indian
Maharashtra
Raigad
23-01-2023

Tender Details

Invitation To Pre-Tender Meet- For Building Works 3 - Admin And Misc. Buildings For Pdh-Pp Project At Gail Usar - 1 Cat 6A Lszh Utp Cable 305M Box 1.1 Utp Cat-6A Gigabit Copper Cable As Per Ansi / Eia / Tia-568C.2 1.2 Shall Be Fire-Retardant As Per Iec 60332 / Equivalent, Low-Smoke As Per Iec- 61034 / Equivalent & Zero-Halogen Iec-60754 / Equivalent 1.3 All Utp Cables Shall Be Of Solid 4-Pair; Pvc Insulated Category-6A Type And Shall Conform To Latest Eia / Tia Standards. 1.4 The Outer Jacket Of The Cable Shall Have Length Printed On It After Every Meter. 1.5 Shall Be Rohs Compliant 1.6 Shall Be Supplied In Reel Of 305 Meters Packed In Boxes 1.7 Shall Be Certified By Independent Testing Laboratory Like Etl For Conformance To Eia / Tia- 568C.2 2 Cat 6A I / O 2.1 Shall Conform To Category-6A As Per The Eia / Tia-568C.2 2.2 Shall Support Network Line Speeds Up To 10 Gbps 2.3 Shall Have Rj-45 Type Connector 2.4 Shall Be Of High Performance Type 2.5 Shall Snap Into Standard Faceplates, Surface-Mount Boxes, Consolidation Point Boxes, And Modular Panels 2.6 Shall Be Mountable Either At 90 Degrees ( Straight ) Or 45 Degrees ( Angled ) In Any Faceplate. 2.7 Shall Be Certified By Independent Labs Like Etl For Compliance To Eia / Tia-568C.2, 2.8 Shall Be Rohs Compliant 3 Cat 6A Modular Patch Cord-3Ft 3.1 All Patch Cords Shall Conform To Category-6A As Per The Eia / Tia-568C.2 3.2 Shall Support Network Line Speeds Up To 10 Gbps 3.3 Shall Have Factory Crimped Rj-45 Jacks At Both The Ends And Length Shall Be 3Ft 3.4 Shall Be Fire-Retardant As Per Iec 60332 / Ul-94-V-0 / Equivalent, Low-Smoke As Per Iec-61034 / Equivalent & Zero-Halogen Iec-60754 / Equivalent 3.5 Shall Be Certified By Independent Testing Laboratory Like Etl For Conformance To Eia / Tia- 568C.2 4 Cat 6A Modular Patch Cord-7Ft 4.1 All Patch Cords Shall Conform To Category-6A As Per The Eia / Tia-568C.2 4.2 Shall Support Network Line Speeds Up To 10 Gbps 4.3 Shall Have Factory Crimped Rj-45 Jacks At Both The Ends And Length Shall Be 7Ft 4.4 Shall Be Fire-Retardant As Per Iec 60332 / Ul-94-V-0 / Equivalent, Low-Smoke As Per Iec-61034 / Equivalent & Zero-Halogen Iec-60754 / Equivalent 4.5 Shall Be Certified By Independent Testing Laboratory Like Etl For Conformance To Eia / Tia- 568C.2 5 Cat 6A Jack Panel - 24 Port 5.1 Shall Be Loaded With 24 Nos. Category-6A I / O Complying With Tia-568 C.2 5.2 Shall Be 19” Rack Mountable And Of 1U Height & Complete With All Mounting Accessories. 5.3 Shall Have Rear Cable Management Features, Shall Be Loaded And Shall Have Termination Manager For Proper Termination Of Cables At Rear. 5.4 Shall Have Comprehensive Individual Port Numbering On Front 5.5 Shall Be Supplied With Rear Cable Management As A Standard Accessory And This Shall Only Occupy The Same Space As The Panel 5.6 Shall Be Certified By Independent Testing Laboratory Like Etl For Conformance To Eia / Tia- 568C.2 6 Face Plate Including Gangbox 6.1 Shall Be ( Rj45 ) Square Plate, Dimension As Per Commercially Available Modular Office Furniture. 6.2 Shall Have Spring Shuttered Front Access For Preventing Ingress Of Dust 6.3 Shall Supply Gang Box Of The Same Size. 6.4 Shall Have Write On Labels In Transparent Plastic Window Along With The Plate 6.5 Shall Have Screw Hole Covers Along With The Plate 6.6 Shall Be Able To Support Variety Of Jacks – Utp And Angular I / O 7 Ethernet Switch Rack-42U 7.1 Shall Be Floor Mounting Type 7.2 Shall Have The Following Dimension: 800 ( W ) X 800 ( D ) X 42 U ( H ) 7.3 Shall Conform To Din 41494 / Eia- 310 7.4 Shall Be Powder Coated Steel Cabinet And Cabinet Color Shall Be Black Ral 9005 7.5 Shall Have Locking Arrangement As Per Oem Standard 7.6 Shall Have 19 Inch Rail Equipment Mounting Frame With Notches At Regular Intervals For Mounting Equipment As Per Industry Standard 7.7 Shall Have Front Door With Glass Cover 7.8 Shall Be Provided With 2 Nos. Vertical Cable Manager 7.9 Shall Have 4 Nos. Brushless Fans With Fan Tray Mounted On The Top Cover For Equipment Cooling 7.10 Shall Have 2 Nos. Power Distribution Units ( Pdus ) Strips Each With 4 Nos. 3-Pin Socket 16 / 6 A, 230 V Ac Power Outlets And Cabinet Earthing / Grounding Facility Shall Be Provided 7.11 Shall Have Ventilation Louvers Or Uniform Perforation On Side Panel And Rear Door 7.12 Shall Have Steel Top Cover And Bottom Panels With Cable Entry Facilities 7.13 Shall Have Floor Mounting Kit; Floor Mounting Accessories ( Such As Adjustable Screws Legs, Wheels, Nuts, Bolts, Washers, Clip-On Nuts For Equipment Mounting Etc. ) And Assembly Hardware 7.14 Shall Have Other Accessories: Castors With Foot Operated Brakes 7.15 Led Light Shall Be Provided In Cabinet 8 Ethernet Switch Rack-15U 8.1 Shall Be Wall Mounting Type. 8.2 Shall Be Double-Section, Swing-Open Type 8.3 Shall Have The Following Dimension: 600 ( W ) X 600 ( D ) X 15 U ( H ) 8.4 Shall Conform To Din 41494 / Eia- 310 8.5 Shall Be Powder Coated Steel Cabinet And Cabinet Color Shall Be Black Ral 9005 8.6 Shall Have Locking Arrangement As Per Oem Standard 8.7 Shall Have 19 Inch Rail Equipment Mounting Frame With Notches At Regular Intervals For Mounting Equipment As Per Industry Standard 8.8 Shall Have Front Door With Glass Cover 8.9 Shall Be Provided With Cable Manager 8.10 Shall Be Provided With Fans For Ventilation With Top Cover 8.11 2 Nos. Power Distribution Unit ( Pdu ) Strips, Each With 4 Nos. 3-Pin Socket 16 / 6 A, 230 V Ac Power Outlets 8.12 Cable Entries From Top And Bottom Panel And Cabinet Earthing / Grounding Facility Shall Be Provided 8.13 Led Light Shall Be Provided In Cabinet 9 Pvc Conduits 9.1 Isi Approved Pvc Conduits ( Min. Dia Of 50 Mm ) 10 Pvc Channels 10.1 Isi Approved Pvc Channels ( Min. Dia Of 25 Mm )

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 14-01-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 18-01-2023
2 18-01-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 23-01-2023

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document