Tender For Renovation Modernization Of Electrical Installations Including, Rewiring, Providing Service Connection Cables And Improvement Of Internal External Lighting With Led Light Fittings For Shed No. 1, Mini Sheds And Ancillaries At Fsd Chanpatia
Tender Overview
Project Description
Renovation Modernization Of Electrical Installations Including, Rewiring, Providing Service Connection Cables And Improvement Of Internal External Lighting With Led Light Fittings For Shed No. 1, Mini Sheds And Ancillaries At Fsd Chanpatia
BOQ
| Sl. No. | Item Description |
| 1 | Supplying and fixing of 200 A, 4 pole,50 HZ,415 V,Switch disconector fuse unit(with Bolted Type Fuse) in Sheet Steel enclosure with 4 Fuses,on existing panel board/wall surface including drilling holes , making connections, etc. as required. |
| 2 | Supplying and fixing of 125 A, 4 pole,50 HZ,415 V,Switch disconector fuse unit(with Bolted Type Fuse) in Sheet Steel enclosure with 4 Fuses,on existing panel board/wall surface including drilling holes , making connections, etc. as required. |
| 3 | Supplying and fixing of 4 way, 200 amps wall mountedbusbar chamber (with steel enclosure containing 4 aluminium busbars) and fixing on the wall including giving connections etc, at site of work as required. |
| 4 | Supply of ISI marked 1100V Aerial Bunched Cable having XLPE insulated Cable (three Power Core) with stranded compact circular aluminium conductors of size 35 sq mm twisted over an insulated aluminium alloy messenger wire for use as overhead distribution lines suitable for use on 3-Phase AC System etc as required. |
| 5 | Supplying ofXLPE Armoured cable with aluminium conductor of 1.1 KV grade confirming to IS:7098 (Part- I) 1988 with up to date ammendments of the following sizeas required.A) 3.5 X 25 sq mm |
| 6 | B)4 X 16 Sq.mm |
| 7 | C) 3 X 6 Sq.mm |
| 8 | D) 2 X 10 sq. mm |
| 9 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 10 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.Upto 35 sq. mm |
| 11 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm |
| 12 | Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as require 100 mm dia. |
| 13 | Supplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required. |
| 14 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.A) Upto 35 sq. mm |
| 15 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.A) 3½ X 25 sq. mm (28mm) |
| 16 | B) 4 X 16 sq. mm (28 mm) |
| 17 | C) 2 X 10 sq. mm (19mm) |
| 18 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.A) 6 X 4 sq. mm |
| 19 | B) 3 X 4 sq. mm |
| 20 | C) 6 X 2.5 sq. mm |
| 21 | D) 3 X 2.5 sq. mm |
| 22 | E )3 X 1.5 sq. mm |
| 23 | F )6 X 1.5 sq. mm |
| 24 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.A) 25 mm |
| 25 | B )20 mm |
| 26 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as requiredA) 4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire |
| 27 | B) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 28 | Supplying and drawing of 1.5 Sq.mm,three core PVC insulated and FR PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volts, conforming to IS: 694 in the existing surface/ recessed steel/ PVC conduit as required. |
| 29 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)4 way (4 + 12), Double door |
| 30 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)A) 8 way, Double door |
| 31 | B) 6 Way, Double Door |
| 32 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts “C” curve DP MCB complete with connections, testing and commissioning etc. as required. |
| 33 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. A)Single pole |
| 34 | B) Single Pole & Neutral |
| 35 | C) Triple pole and neutral |
| 36 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 37 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.(A) Group C |
| 38 | Supply of 20W LED T8 tube with extruded Al body, PC diffuser and inbuilt driver with efficacy min of 100 lumens/W along with Surface/Suspended waterproof industrial luminaire(IP 66) with polycarbonate housing and diffuser suitable for single 4 ft T8 tube etc.at the site of work. |
| 39 | Supply of 20W LED T8 tube with extruded Al body, PC diffuser and inbuilt driver with efficacy min of 100 lumens/W along with Highly robust Industrial Box type(not compact type) luminaire suitable for single T8 LED Tube etc.at the site of work. |
| 40 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 41 | Supplying, installation, Testing and commissioning of 30 Watt Flood light fitting made up of pressure die cast alluminium housing with IP 65,IK 07,LEDs with lumen efficacy of =140 lm/W, System efficacy of=105 lm/W,colour temp 5700 K,THD( %)= 10 and fixing on wall/truss/pole with suitable clamps and nut bolts including giving connection etc., at site of work as required. |
| 42 | Supplying, installation, Testing and commissioningof70 watt LED typeWell Glass luminaires in pressure die-cast aluminium housing with IP 66, LEDs with lumen efficacy of =140 lm/W, System efficacy of=110 lm/W,colour temp 5700 K,THD( %)= 10, Polycarbonate diffuser in opal finish and fixing on truss with suitable clamps and nut bolts and also dismantling the existing fitting etc at the site of work as required. |
| 43 | Supplying, installation, Testing and commissioning of40W LED Street light fitting made up of pressure die cast alluminium housing with IP 66,IK 07, LEDs with lumen efficacy of =140 lm/W, System efficacy of=110 lm/W,colour temp 6500 K,THD( %)= 10 and fixing on wall/truss/pole with suitable clamps and nut bolts including giving connection etc., at site of work as required. |
| 44 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.A) 75 mm X 75 mm X 60 mm deep |
| 45 | B) 200 mm X 125 mm X 60 mm deep |
| 46 | Supplying and fixing of 600mm x 600mm size metalic frame cover fabricated with 35 mm x 35 mm x 5 mm thick angle iron welded construction frame structured and 3 mm thick M. S. sheet cover plate panel with double hinges and knobe type locking arrangement including painting, making recess in wall, masonary, plastering & finishing the good (As per directions of Engineer-In Charge) |
| 47 | Supplying and fixing of 300mm x 300mm size metalic frame cover fabricated with 35 mm x 35 mm x 5 mm thick angle iron welded construction frame structured and 3 mm thick M. S. sheet cover plate panel with double hinges and knobe type locking arrangement including painting, making recess in wall, masonary, plastering & finishing the good (As per directions of Engineer-In Charge) |
| 48 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. A) 5/6 amps switch |
| 49 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required.A) 12 Module (200mmX150mm) |
| 50 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.A) 15/16 amp switch |
| 51 | B) 6 pin 15/16 amp socket outlet |
| 52 | C) 5/6 amps switch |
| 53 | D) 3 pin 5/6 amp socket outlet |
| 54 | Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required. |
| 55 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 56 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. |
| 57 | Supplying and fixing of Hot pressed moulded SMC Junction box of size 230mm x 170mm x 105mm with 6A SP MCB, 2/4 way Strip connector etc. as required at the site of work. |
| 58 | Dismantle of 20/25 existing old conduit at any height, cleaning and refixing of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. |
| 59 | Supplying and fixing of 32 mm dia X 1.00 metres long G.I. pipe (medium class) bracket for mounting of all type of street light fitting on pole / wall / structure including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint as required. |
| 60 | Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required. |
| 61 | Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 62 | Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps \"C\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 63 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : |
| 64 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 65 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 66 | Supply of RCC/PCC pole of 8 meter length along with angle bracket & other fittings to hold UG/ABC cable on top including clamps and bolts as required. |
| 67 | Erection of RCC/ PCC pole of following length in brick ballast and ramming the foundation, finishing with 150mm thick cement concrete (1:3:6) layer on top with including excavation and refilling etc as required.A) Above 6.5 metre and upto 8 metre |
| 68 | Disposal of Dismantled ACSR Conductor |
| 69 | Disposal of Dismantled Box Type conventional light fittings |
| 70 | Disposal of Dismantled Iron Scraps (MS Conduits, Switch Boards, DB\"s etc) |
| 71 | Disposal of Dismantled Aluminium Scraps (Wires etc) |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender