Agriculture Boards / Undertakings / PSU Closing in 0 days TDR #35658645

Tender For Renovation Modernization Of Electrical Installations Including, Rewiring, Providing Service Connection Cables And Improvement Of Internal External Lighting With Led Light Fittings For Shed No. 1, Mini Sheds And Ancillaries At Fsd Chanpatia

Issued by Boards / Undertakings / PSU · chanpatia, Bihar
Tender Value
22.07 Lakhs
Estimated cost
Bid Submission
23 Jan 2023
0 days left
EMD
44160
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
chanpatia → Bihar
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Renovation Modernization Of Electrical Installations Including, Rewiring, Providing Service Connection Cables And Improvement Of Internal External Lighting With Led Light Fittings For Shed No. 1, Mini Sheds And Ancillaries At Fsd Chanpatia

BOQ

Name of Work:Renovation/Modernization of Electrical Installations including, re-wiring, providing service connection cables and improvement of internal/external lighting with energy saving LED light fittings for Shed No. 1, Mini Sheds and ancillaries at FSD, Chanpatia.
Sl. No. Item Description
1Supplying and fixing of 200 A, 4 pole,50 HZ,415 V,Switch disconector fuse unit(with Bolted Type Fuse) in Sheet Steel enclosure with 4 Fuses,on existing panel board/wall surface including drilling holes , making connections, etc. as required.
2Supplying and fixing of 125 A, 4 pole,50 HZ,415 V,Switch disconector fuse unit(with Bolted Type Fuse) in Sheet Steel enclosure with 4 Fuses,on existing panel board/wall surface including drilling holes , making connections, etc. as required.
3Supplying and fixing of 4 way, 200 amps wall mountedbusbar chamber (with steel enclosure containing 4 aluminium busbars) and fixing on the wall including giving connections etc, at site of work as required.
4Supply of ISI marked 1100V Aerial Bunched Cable having XLPE insulated Cable (three Power Core) with stranded compact circular aluminium conductors of size 35 sq mm twisted over an insulated aluminium alloy messenger wire for use as overhead distribution lines suitable for use on 3-Phase AC System etc as required.
5Supplying ofXLPE Armoured cable with aluminium conductor of 1.1 KV grade confirming to IS:7098 (Part- I) 1988 with up to date ammendments of the following sizeas required.A) 3.5 X 25 sq mm
6B)4 X 16 Sq.mm
7C) 3 X 6 Sq.mm
8D) 2 X 10 sq. mm
9Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)
10Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.Upto 35 sq. mm
11Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm
12Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as require 100 mm dia.
13Supplying and fixing of light class G.I. pipe of 50 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required.
14Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.A) Upto 35 sq. mm
15Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.A) 3½ X 25 sq. mm (28mm)
16B) 4 X 16 sq. mm (28 mm)
17C) 2 X 10 sq. mm (19mm)
18Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.A) 6 X 4 sq. mm
19B) 3 X 4 sq. mm
20C) 6 X 2.5 sq. mm
21D) 3 X 2.5 sq. mm
22E )3 X 1.5 sq. mm
23F )6 X 1.5 sq. mm
24Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.A) 25 mm
25B )20 mm
26Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as requiredA) 4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire
27B) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
28Supplying and drawing of 1.5 Sq.mm,three core PVC insulated and FR PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volts, conforming to IS: 694 in the existing surface/ recessed steel/ PVC conduit as required.
29Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)4 way (4 + 12), Double door
30Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)A) 8 way, Double door
31B) 6 Way, Double Door
32Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts “C” curve DP MCB complete with connections, testing and commissioning etc. as required.
33Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. A)Single pole
34B) Single Pole & Neutral
35C) Triple pole and neutral
36Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
37Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.(A) Group C
38Supply of 20W LED T8 tube with extruded Al body, PC diffuser and inbuilt driver with efficacy min of 100 lumens/W along with Surface/Suspended waterproof industrial luminaire(IP 66) with polycarbonate housing and diffuser suitable for single 4 ft T8 tube etc.at the site of work.
39Supply of 20W LED T8 tube with extruded Al body, PC diffuser and inbuilt driver with efficacy min of 100 lumens/W along with Highly robust Industrial Box type(not compact type) luminaire suitable for single T8 LED Tube etc.at the site of work.
40Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
41Supplying, installation, Testing and commissioning of 30 Watt Flood light fitting made up of pressure die cast alluminium housing with IP 65,IK 07,LEDs with lumen efficacy of =140 lm/W, System efficacy of=105 lm/W,colour temp 5700 K,THD( %)= 10 and fixing on wall/truss/pole with suitable clamps and nut bolts including giving connection etc., at site of work as required.
42Supplying, installation, Testing and commissioningof70 watt LED typeWell Glass luminaires in pressure die-cast aluminium housing with IP 66, LEDs with lumen efficacy of =140 lm/W, System efficacy of=110 lm/W,colour temp 5700 K,THD( %)= 10, Polycarbonate diffuser in opal finish and fixing on truss with suitable clamps and nut bolts and also dismantling the existing fitting etc at the site of work as required.
43Supplying, installation, Testing and commissioning of40W LED Street light fitting made up of pressure die cast alluminium housing with IP 66,IK 07, LEDs with lumen efficacy of =140 lm/W, System efficacy of=110 lm/W,colour temp 6500 K,THD( %)= 10 and fixing on wall/truss/pole with suitable clamps and nut bolts including giving connection etc., at site of work as required.
44Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.A) 75 mm X 75 mm X 60 mm deep
45B) 200 mm X 125 mm X 60 mm deep
46Supplying and fixing of 600mm x 600mm size metalic frame cover fabricated with 35 mm x 35 mm x 5 mm thick angle iron welded construction frame structured and 3 mm thick M. S. sheet cover plate panel with double hinges and knobe type locking arrangement including painting, making recess in wall, masonary, plastering & finishing the good (As per directions of Engineer-In Charge)
47Supplying and fixing of 300mm x 300mm size metalic frame cover fabricated with 35 mm x 35 mm x 5 mm thick angle iron welded construction frame structured and 3 mm thick M. S. sheet cover plate panel with double hinges and knobe type locking arrangement including painting, making recess in wall, masonary, plastering & finishing the good (As per directions of Engineer-In Charge)
48Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. A) 5/6 amps switch
49Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required.A) 12 Module (200mmX150mm)
50Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.A) 15/16 amp switch
51B) 6 pin 15/16 amp socket outlet
52C) 5/6 amps switch
53D) 3 pin 5/6 amp socket outlet
54Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required.
55Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
56Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
57Supplying and fixing of Hot pressed moulded SMC Junction box of size 230mm x 170mm x 105mm with 6A SP MCB, 2/4 way Strip connector etc. as required at the site of work.
58Dismantle of 20/25 existing old conduit at any height, cleaning and refixing of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
59Supplying and fixing of 32 mm dia X 1.00 metres long G.I. pipe (medium class) bracket for mounting of all type of street light fitting on pole / wall / structure including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint as required.
60Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required.
61Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
62Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps \"C\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
63Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :
64Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
65Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
66Supply of RCC/PCC pole of 8 meter length along with angle bracket & other fittings to hold UG/ABC cable on top including clamps and bolts as required.
67Erection of RCC/ PCC pole of following length in brick ballast and ramming the foundation, finishing with 150mm thick cement concrete (1:3:6) layer on top with including excavation and refilling etc as required.A) Above 6.5 metre and upto 8 metre
68Disposal of Dismantled ACSR Conductor
69Disposal of Dismantled Box Type conventional light fittings
70Disposal of Dismantled Iron Scraps (MS Conduits, Switch Boards, DB\"s etc)
71Disposal of Dismantled Aluminium Scraps (Wires etc)

AI Tender Summary

OUR REF NO 35658645
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 22.07 Lakhs
LAST DATE 23-01-2023
Authority
Authority Name Food Corporation Of India
Work Description Renovation Modernization Of Electrical Installations Including, Rewiring, Providing Service Connection Cables And Improvement Of Internal External Lighting With Led Light Fittings For Shed No. 1, Mini Sheds And Ancillaries At Fsd Chanpatia
Basic Detail
Tender No 06/EM/22-23
Bidding Type Tender
Location
City chanpatia
State Bihar
Key Dates
Publish Date 09 Jan 2023
Submission Date 23 Jan 2023
Open Date 24 Jan 2023
Finance
Tender Value 22.07 Lakhs
Tender Fee Ref. Documents
EMD 44160
Exemption Not Available
Document List
4ceec111-8e0b-4b9a-a3d0-52abed939550.html
BOQ_771492.xls
MTFCNP.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jan 09, 2023
11:30 IST

Tender Published

Tender notice published.

Completed
Jan 23, 2023
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jan 24, 2023

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

4ceec111-8e0b-4b9a-a3d0-52abed939550.html

xls

BOQ_771492.xls

pdf

MTFCNP.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders