Housing Urban and Rular Development Government Departments Closing in 0 days TDR #35652115

Tender For Renovation And Repair Work (Electrical) Of Eklavya Model Residential School At Nagrakata Within Jalpaiguri District.

Issued by Government Departments · nagrakata, West Bengal
Tender Value
50.51 Lakhs
Estimated cost
Bid Submission
24 Jan 2023
0 days left
EMD
1.01 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
nagrakata → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Renovation And Repair Work (Electrical) Of Eklavya Model Residential School At Nagrakata Within Jalpaiguri District.

BOQ

Name of Work : Renovation & Repair Work (Electrical) of Eklavya Model Residential School at Nagrakata within Jalpaiguri district.
Sl. No. Item Description
1Dismantlling the existing wiring from DB to point (light ,fan, On board,5A, 20A and computer board wiring). Without damging the Board, DB and polythene pipe.
2Distribution wiring in 3x22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire ((Brand approved by EIC) in 20mm size PVC rigid conduit \"FR\" (Precision make),to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall complete with 2 no. suitable size “Ph & N” copper bar and \"L\" sahped insulator chair incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. 175mmx100mmx65mm inspection box, making earthing attachment, painting the MS box and mending goodthe damages to original finish [equivalet to PWD/GS Page: E-14 Item: 2]
3Average run 10 mtr.
4Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit \"FR\" (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed copper wire as ECC, to 5A 3 pin flush type plug socket & Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. painting the MS box and mending good the damages to original finish
5On Board
6Average run 4.5 mtr
7Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes flushed in wall by housing the same after cutting brick wall incl. making earthing attachment, painting and mending good damages to building works 150 mm x 100 mm x 65 mm
8Supply & Fixing 240 V, 6 A Piano key type switch (Brand approved by EIC) on sheet metal switch board incl. S & F 100x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required[PWD/GS Page: E-6 Item:17/a]
9Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required[PWD/GS Page E-6 Item:22]
10Supply & Fixing 240 V, 3 nos. 6A, & 1 no. 20A plug socket with separate 3 nos. 6 A & 1 no. 20A Piano key type switch with indicator & 16A kit-kat flush type fuse (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required for C.B[PWD/GS Page E-7 Item:25]
11Distribution wiring in 1.1 KV single core stranded \"FR\" PVC insulated & unsheathed copper wire (Havells/Polycab/KEI) in 20mm size PVC rigid conduit \"FR\" (Precision make) incl. necy. fittings as required [equivalet to PWD/GS Page: E-14 Item: E/1/a]
122 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC(Ckt run beyond 12mtr. Av. Run & distribution wiring in running mtr.)
132x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC
142 x 84/0.3 (6 sqmm) + 1 x 56/0.3 (4 sqmm) ECC
154x126/0.4 (16 sqmm) + 2x80/0.4 (10 sqmm)
16Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.[PWD/GS Page: F-5 Item: 9]
172x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm)
182 x 84/0.3 (6 sqmm) + 1 x 56/0.3 (4 sqmm)
194x126/0.4 (16 sqmm) + 2x80/0.4 (10 sqmm)
20Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages tooriginal finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. 2+12 way Enclosure (607712) Make- Legrand/Schneider/ Seimens/ ABB[PWD/GS Page D-9 Item:13]
21Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment 4 way Enclosure (607715) Make- Legrand/Schneider/ Seimens/ ABB[PWD/GS Page D-10 Item:14]
22Supplying and fixing 160 A double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending goodthe damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. 4 way Enclosure (607913) Make- Legrand/Schneider/ Seimens/ ABB[PWD/GS Page D-11 Item:15]
23Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection 100A FP .Make- Legrand/Schneider/ Seimens/ ABB.[PWD/GS Page D-8 Item:10]
24Supply & fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection (Legrand /Siemense /Havells Metalica /ABB Elegance - as per direction of EIC)[PWD/GS Page: D-6 Item: 7]
2563A FP MCB for TPN incoming
2640A DP MCB For SPN incoming
276-32A SP MCB
2863 A TP MCB For VTPN outgoing
29Supplying and fixing double door sheet steel (16SWG), powder coated cable end box for TPN DB horizontal / vertical enclosure with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish with nuts bolts etc incl. provision for earthing attachment (PWD, D-12, ITEM-16)
304 way
3112 way
32Supply & Delivery 4ft LEDSingle tube Light fittings with LED tube [Make: Crompton/Havvels/Philips Essential LED 20- W865, TMC- 501 P 1xT-LED 22W P3241] / as per direction of EIC.
33Fixing only single/twin florescent light fitting complete with allaccessories Directly on wall/ceiling with HW block and suitable size MS fastener, Ceiling plate, nipples etc. as required. C-2 14(d)
34Supply & Delivery 48\" (1200mm) AC ceiling fan make: (Orient Summercool / Crompton High Speed/ Havells Velocity / as per direction of EIC)complete with down rod, canopy fork, bladeswith all other accessories etc. but without regulator with safety rope.
35Fixing only ceiling fan complete with blades, canopy, fork, rubberbush etc. incl. S&F connecting wire for down rod upto 30 cm incl.painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire.[PWD/GSPage-C-3/21-a]
36Supply & Fixing Socket type fan regulator (Step type)(Brand approved by EIC) on existing sheet metal switchboard with bakelite/perspex top cover by screw aftermaking housing for regulator knob by cuttingbakelite/perspex top cover incl. making necy. connections.[PWD/GSPage-E-6/18-a]
37Supply & Delivery of 10W LED Lamp (Make- Philips/Crompton/Havells)
38Supply & Fixing Angular batten Holder (Anchor or Equivalent)
39Panel:
40Panel No. 1: Supply delivery installation testing & commissioning Indoor Cubical type L.T. Distribution panel board of appropriate size base mounted cmpartmentalized with maple arrangement having rigid & self supporting structure with cable allay fabricated from 2 mm thick CRCA sheet steel with 25X25X6mm MS angle frame and 75X40X40mmX4.4mm M.S. Channel for base support. And making masonary trench of 600mm depth and suitable length & widein matching with Panel with 10\" brick work, plastering & neetcementing as per direction of EIC. The Pannel should be made from CPRI certified or equivalentPanel making workshop. The panel board consisting of the following item-
41500V, 400A electrolyte grade tinned copper BBC with vertical section of 50X5mm sizefor neutral & Phases.Bus-bar shall be fixed with FRP insulator chair & the entire bars are insulated with PVC heat Sinkable sleeve of suitable size & color as per direction of E.I.C [equal bar for each i.e. 4-bar]And interconnections for: 250A SFU/CO is 30X5mm copper bar, for 200A SFU is 25X5mm copper bar, for 100A SFU is 50sqmm copper wire & for 32A SFU is 16sqmm copper wire.
42Incomming:415V 200A SFU with DIN type HRC fuse01 nos.415V 250A Changeover01 no.Outgoing:415V 100A SFU with DIN type HRC fuse04 nos.415V 63A SFU with DIN type HRC fuse01 no.415V 32A SFU with DIN type HRC fuse02 no.Other equipments:400/5A CT (Kappa) 03 nos.Multi Function Meter VAF meter - 1 No.LED R-Y-B indicator with 3 nos. Legrand 6A SP MCB 01 itemSupply & Fixing Danger Board01 no.(Make: L& T/Havells/ABB)
43Renovation and Rewiring of existing LT panel as per direction of EIC. Painting with one coat of R.O. primer and two coat of synthetic enamel paint including Cleaning and interconnection with suitable copper strip / copper conductor of appropiate capacity including socketing and earth stud both in the body complete.Supply & fixingMain Incoming Switch 4P 200A - 1 Nos WITH FUSE and S & fixing of outgoing Main switch with WITH FUSE 63A TP - 3 Nos, 32A TP - 1 Nosincluding supply & fixing of cable gland as when required and Checking the all incoming and outgoing main switchs,changing the finshing end if needed and tighting all nut-bolts and other tit bit repairing as per Direction of EIC
44Supplying and fixing 415V,63A TPN SFU in existing panel after dismantling the existing mainswitch with S & f of DIN fuse unit along with necessary interconnection of suitable size. PWD - D4, 4b
45Compound Light:
46Supply & Delivery 90W outdoor Type LED Light ( Make- Philips/ Crompton- LSTP-90 CDL-M/ Havells)
47Supply & Delivery 150W outdoor Type LED Light ( Make- Philips/ Crompton/ Havells) (Crompton - LST 150 CDL)
48Fixing only Floodlight Fitting with suitable tie clamps and MS platefor mounting on Pole/Tower or similar structure[PWD/GS Page: C-3 Item: 20]
49Providing CC (6:3:1) muffing 600x600x760 mm in size orequivalent size of cylindrical muffing above ground level aroundthe pole base complete with 3 mm thick neatly finished cement plaster all round after dismantling the unserviceable muffing if necessary.Use PVC 25mm conduit for cable in & out. (b) With 250x250x100mm 16 SWG GI Loop Box[PWD/GS Page: -I-1 /12]
50Fixing only outdoor / street light type fluorescent light fitting or MV light fitting complete with all accessories to be fixed /projected from the wall of the building incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bendS&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc. PWD c-3, 18
51Painting of9.0 mtr. long Steel Tubular Pole of lengths andOne coat of red lead/Zinc hromate priming & 2 no. of coats synthetic enamel paint/ aluminium paint, as given below with ready mixed paint/primer of approved make, and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paint (as per direction of EIC) [PWD/GS Page: H-2 Item: 7/A]
52Supply & delivery of 1.1 KV Gr. XLPE/ PVC Armoured Aluminium Cable (Havells / Polycab / Approved by EIC).
534 Core 70 sq mm
544 Core 50 sq mm
554 Core 35 sq mm
564 Core 16 sq mm
574 Core 10 sq mm
58Laying of cable above 3½ /4core 50 sqmm and upto 3½/4 core 90 sqmm on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting
59Laying of one No. cable above 35 sqmm and upto 185 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoringsurface duly rammed
60Laying of cable from 3/3½/4 core 35 sqmm to 50 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making holes etc. as necy., mending good damages and painting
61Laying of one No. cable upto 35 sqmm in underground trench 460mm wide x 760 mm average depth, with brick protection on thetop of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed[PWD/GS Page: F-2 Item: 1/A]
62Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting
63S & F compression type brass cable glandcomplete with brass gland, brass ring & rubber ring for dust & moisture proof entry of XLPE/PVC armoured cable.[PWD/GS Page No.: F-4Item No.: 7/c]
644 Core 70 sq mm
654 core 50 sqmm
664 Core 35 sq mm
674 Core 16 sq mm
684 core 10 sqmm
69Finishing the end of the XLPE/PVC armoured cableas by crimping method incl. S&F solderless socket (Dowels make), tapes, anticorrosive paste & joiting materials.[PWD/GS Page No.: F-5Item No.: 8/b]
704 Core 70 sq mm
714 core 50 sqmm
724 Core 35 sq mm
734 Core 16 sq mm
744 core 10 sqmm
75Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire, with an average depth of 3.65 Mts. below the ground level (For soft Soil: ISI-Medium GI pipe)[PWD/GS Page No.: G-1 Item No.:2/a]
76Excavation of soil for installation of Earth Electrode and filling & ramming. (Soft Soil)[PWD/GS Page: G-1 Item:1]
77Extra for providing masoneryenclosure on the top of the earthelectrode of overall size 86.36 cm x 86.36 cm x 46 cm deep(below Ground level) complete with cemented brick work(1:6)of 25 cm width duly plastered with cement morter (inside) CIhinged inspection cover of size 36.56 cm x 35.56 cm with lockingarrangement, GI reducer including drilling of 46 nos. 12 mm diaholes on the GI pipe [PWD/GS Page: G-2 Item: 3/a]
78Extra for treatment of soil by using salt & charcoal or coke for plate electrode [PWD/GS Page: G-2 Item: 3/b]
79S&F earth busbar of galvanized (Hot Dip) MS flaton wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required[PWD/GS Page: G-2 Item: 4/b]
80S&F galvanized (Hot Dip) MS flat 40 mm x 6 mm on wall
81Connecting the equipments body to earth busbar including S&F galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc.
82S&F 25 mm x 6 mm galvanised (Hot Dip) MS flat[PWD/GS Page:G-3 Item: 5/d]
83S&F medium gauge 40mm dia GI Pipe (ISI-Medium) Protection with necessary fittings and jointing metarials as required as per GS.[PWD/GS Page: F-6 Item: 11]
84Supply and fixing on M/S Box of suitable dimensionfor timer circuit as well as supply & fixing of the the following items,i) 40A FP MCB -- 1no; ii) Timer Set daily weekly programmable.(Digital)-- 1 Set; ii) 40A FP Power Contactor -1Set;iii) 16A TP MCB-- 3nos;iv) Auto-manual selector switch---- 1 no. v) LED indicator green - 1 no.vi) 50 A Cu bar - 4 Nos.Make - Havells or equivalent as per direction of EIC.
85Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire, with an average depth of 3.65 Mts. below the ground level (For soft Soil: ISI-Medium GI pipe)for compound Light.
86Excavation of soil for installation of Earth Electrode and filling & ramming. (Soft Soil)
87Extra for treatment of soil by using salt & charcoal or coke for plate electrode
88Connecting the equipments to earth busbar including S & F GI(Hot Dip) wire of size as below on wall/floor with staples buriedinside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages (iii) Solid GI wire No. 8 SWG. Welding Finsh.

AI Tender Summary

OUR REF NO 35652115
AUTHORITY Government Departments
TENDER VALUE 50.51 Lakhs
LAST DATE 24-01-2023
Authority
Authority Name Public Works Department
Work Description Renovation And Repair Work (Electrical) Of Eklavya Model Residential School At Nagrakata Within Jalpaiguri District.
Basic Detail
Tender No WBPWD/EE/JED/NIT 25e/T of 2022-23 (2nd Call).
Bidding Type Tender
Location
City nagrakata
State West Bengal
Key Dates
Publish Date 09 Jan 2023
Submission Date 24 Jan 2023
Open Date 27 Jan 2023
Finance
Tender Value 50.51 Lakhs
Tender Fee Ref. Documents
EMD 1.01 Lakhs
Exemption Not Available
Document List
69252956-64f6-44a8-8a4b-598eb365a114.html
2911ii.pdf
Additional_Documents.pdf
BOQ_878642.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jan 09, 2023
11:30 IST

Tender Published

Tender notice published.

Completed
Jan 24, 2023
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jan 27, 2023

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

69252956-64f6-44a8-8a4b-598eb365a114.html

pdf

2911ii.pdf

pdf

Additional_Documents.pdf

xls

BOQ_878642.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders