Tender For Repair Replacement Of Street Light Fittings Mccb Lt Overhead Underground Line Including Exteral Water Supply Fittings And Pipe Line And Maintanance Of Heating And Cooling Appliances At Haldwani Kamola And Ranibagh Under Ge Ranikhet, haldwani-Uttarakhand

Military Engineer Services-MES has published Tender For Repair Replacement Of Street Light Fittings Mccb Lt Overhead Underground Line Including Exteral Water Supply Fittings And Pipe Line And Maintanance Of Heating And Cooling Appliances At Haldwani Kamola And Ranibagh Under Ge Ranikhet. Submission Date for this Tender is 04-02-2023. MCCB Tenders in haldwani Uttarakhand. Bidders can get complete Tender details and download the document.




Tender Notice

35650560
Corrigendum : Tender For Repair Replacement Of Street Light Fittings Mccb Lt Overhead Underground Line Including Exteral Water Supply Fittings And Pipe Line And Maintanance Of Heating And Cooling Appliances At Haldwani Kamola And Ranibagh Under Ge Ranikhet
Open Tender
Indian
Uttarakhand
haldwani
04-02-2023

Tender Details

Repair Replacement Of Street Light Fittings Mccb Lt Overhead Underground Line Including Exteral Water Supply Fittings And Pipe Line And Maintanance Of Heating And Cooling Appliances At Haldwani Kamola And Ranibagh Under Ge Ranikhet

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 11-Jan-2023 CORRIGENDUM NO-01 Other 28-01-2023
2 16-Jan-2023 CORRIGENDUM NO-02 BOQ 28-01-2023
3 28-Jan-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 04-02-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 68900.0 /-
Tender Value
INR 34.45 Lakhs /-

BOQ Items

Name of Work: Repair / Replacement of street fittings, MCCB, LT Over Head/under ground line incl external water supply fittings and pipe line and maint of heating and cooling appliances at Haldwani, Kamola and Ranibagh under GE Ranikhet
Sl. No. Item Description
1BOQ ( Sch "A") B/R Demolition of cement concrete in ground floors and pavings n.exc 15cm thickness (below or above ground level) complete all as specified & directed.
2Demolition of cement concrete of any description and in any position not other wise specifically provided for complete all as specified and directed.
3Demolition of brick work or stone boulder masonry or precast PCC block masnory built in cement mortar including all quoins, arches,pillars ets but excludig ashaler facings, dressed stone work complete all as specified and directed.
4M&L for brick work with sub class `B’ bricks, old size, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed.
5Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing and rubbish off the premises complete all as specified and directed.
6M&L for 25mm thick PCC 1:2:4 type B-0 (Using 12.5 mm graded stone aggregate) as in level course with finishing in cement concrete surface even and rough to receive floor finishes complete all as specified and directed.
7M & L for Joint free Non - skid coloured ceramic tiles 7 to 10 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over with and including screed bed of 15 mm thick in CM 1:6 complete all as specified & directed.
8M&L for Glazed coloured ceramic tiles in verticle surfaces of size 450 x 300 x 7mm thickset and jointed in neat cement slurry and pointed in white orcoloured cement to match with and including backcoat of screed bed or bedding layer 10mm thick in CM 1:4 complete all as specified& directed.
9M&L for cutting chases in brick walls or stone or concrte block massonry, pinning in, making good to facing where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades shelves, lintels etc, and cutting chases for concealed water tubing or concealed conduit wiring etc and making good, cutting not exc 10cm girth complete all as specified& directed.
10Taking up or down old unserviceable15mm dia (bore) GI Water Tubing and Connections and removing from site complete all as specified and as directed.
11Taking up or down old unserviceable25mm dia (bore) GI Water Tubing and Connections and removing from site complete all as specified and as directed.
12S&F 15mm dia (bore) steel water tubing, "medium grade" galvanised, with all GI fittings fixed complete toWalls, Ceiling or laid in Floors or any other Situation, complete all as specified and as directed.
13S&F 25mm dia (bore) steel water tubing, "medium grade" galvanised, with all GI fittings fixed complete toWalls, Ceiling or laid in Floors or any other Situation, complete all as specified and as directed.
14S&F in repairs 15mm dia bib taps, CP cast copper alloywith crutch or butterfly handle,screweddown, screwed for iron pipe or for brass ferrul complete all as specified and as directed.
15S&F 15 mm bore pillar taps, fancy type, cast copper alloy, with capsten heads chromium plated, screwed down high pressure, with or without lettered hot or cold with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and as directed.
16S&F in repair Angle Cock,15mm bore fancy type, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed.
17S&F Ball Brass Valves , 25mm dia,quarter turn, femaled threaded, screwed both ends for iron pipe for unions, complete all as specified and directed.
18S&F 20mm dia tubular towel Rail CP Brass, chromium plated D type with CP Brackets, 600 mm long between flanges complete all as specified and directed.
19Supply & Fixing in repairs vitreous China squatting pan, Orissa pattern incl CI trap, size 580 x 440 mm white, with integral foot rests with squatting pattern closet also includes setting the trap and pan in lime concrete (1 lime, 2 sand or surkhi and 5 aggretate), min. 150mm thick all round and finished just below level of rim of pan to receive the floor finishing (thickness as indicated) and making good floor complete all as specified incl cutting to the flush pipe and necessary repair to the floor complete all as specified and directed.
20S&F in repairs PVC Flushing Cistern 10 litre capacity, low level, valve less, symphonic action type, white, with inlet, ball valve Float and handle including 32mm dia PVC Flush Pipe, a Pair of MS Brackets, including Cutting and Pinning in Ends of brackets and making Good Disturbed Surfaces in Cement Mortar 1:3 complete all as specified and as directed.
21Supply & Fixingin repairs vitreous china wash basin, white, flat back, size 550mm x 400mm, including brackets,PVC waste pipe 32mm dia,wastecoupling brass, chromium plated and including cutting for and pinning in ends of brackets or erecting stand complete all as specified and directed.
22S&F in repairs PVC connections 15mm size with PTMT nuts of length 450mm and fixed, complete all as specified and as directed.
23Supply & fixing in repair110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed including all necessary fittings in any length with rubber ring joints fixed with clamps of flat iron of suitable size and including bolts and nuts and securing ends of stays to wall or roof and making good with cement mortor 1:3 or with PCC 1:2:4 complete all as specified and directed.
24S &F in repair 600x 450mm beveled edge mirror of selected quality glass mounted on 6mm thick AC bldg board or commercial plywood and fixed to wooden plugs with CP brass screws and cup washers complete all as specified and as directed.
25Taking down chowkats or frames n.exc 1.50 sqm each with shutters (without taking off shutters from the frames) and removing from site complete all as specified and as directed.
26Taking down chowkats or frames exc 1.50 sqm but n.exc 4.00sqm each with shutters (without taking off shutters from the frames) and removing from site complete all as specified and as directed.
27S&F factory made solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC Sheet rainforced with MS square tube complete all as specified and as directed.
28S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame work made out of MS tubes for top or bottom rail MS frame shall be covered with heat mouldedplain colour PVC "C" channel having a PVC sheets for trip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail, and bottom rail panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to stiles and rail with suitable PVC sheets beading and jointedtogether with solvent cement supplying and fixing in the frame at site as specified in cluase No 8B.2.1 of SSR Part-II 2020 complete all as specified and directed.
29S&F powder coated Anodised aluminium frame for doors, windows ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
30S&F powder coated Anodised aluminium door shutters, aluminium section weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading, screws etc. complete all as specified & directed.
31Supply & fixingpowder coated aluminium windows and ventilator shutters,slidingor fixed type without sash bars , aluminium section weighting 0.55 kg / m including necessary joining cleats , glazing clips ,roller, rubber packing, anodised aluminium snap beading , screws, anodised aluminium fitting such as peg stays 150 mm long (1 No), hinges type B-21 100 mm long (02 Nos), suitable handle (1 No), locking device, louvers, rollers etc. complete all as specified & directed.(Note:- Glass pane and wire mesh shall be measured and paid separately )
32Supply and fixingpowder coated aluminium designer grill of 5.5 mm dia and aperture of 75 mm fixed with and including aluminium powder coated flat section of size 50 x 1.5 mm complete all as specified and directed.
33Supply only Sheet glass 4.8mm thick tinted glass and glazing in squarescomplete all as specified and directed.
34Supply & fixingaluminium sheet powder coated of thickness not less than 5mm thick to be in sealed as panel in aluminium door including fixingcomplete all as specified and directed.
35Supply & fixingSteel windows with side hung shutters including box type hinge with steel handle and steel peg stay, complete with glazing bars, dovetailed or weldedcomplete all as specified and directed.
36All as per item No.35 above but without glazing bars complete all as specified & directed.
37Supply & fixingsteel ventilators with top hung shutters incl hinges steel peg stay complete all as specified and directed.
38Hacking out old broken glass (any thickness, size, quality or description) from metal frames incl punching or drilling out glazing pins/spring clip and providing and fixing new ones complete all as specified and directed.
39S&F plain sheet glass 3mm thick, ordinary quality and glazing with oil putty in squares exceeding 0.5 Sqm in each pane complete all as specified and directed.
40S&F 3mm thick figured glass pin headed type and glazing with oil putty in square n. exc 0.5 sqm in each pane complete all as specified and directed.
41S&F mild steel wire cloth, 0.45 mm nominal dia of wire and average width of aperature 1.4 mm and fixed with tinned tacks or galvanised wire staples complete all as specified anddirected
42S&F 2nd class hard wood plain solid straight chowkats or frames wrought framed rebated on the solid rounded or chamfered put together with glue pinned at joints complete all as specified and as directed
43M&L for PCC 1:3:6 type C-1(using 20mm graded stone agg) for bed block for fixing hold fast including necessary form work complete all as specified & directed.
44M&L Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified & directed.
45S&F35mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and as directed.
46S&F 2nd class hard wood 35 mm thick glazed and skelton shutter open rebated and prepared to receive glass, gauge etc, (without sash bars) edges of framing plain chamfered or rounded fitted with cut or mitred beads for securing glass etc. size of members of shutters as specified in SSR Part-I, Sec-8, clause 8.23(a)complete all as specified and as directed
47S&F 2nd class hard wood small fittings such as brackets of any type, latch and hinge blocks, shaped door and widnow stops and the like, including all necessary labour; articles not exc 200 cucm each complete all as specified and as directed.
48S&F Aluminium alloy, anodised, sliding door bolt with haps, staple (bolt type) and fixing clips with sheet, cast and extruded section and fixing bolt and sliding bolt of extuded sections or cast aluminium alloy and fixed 250 mm long complete all as specified and as directed.
49S&F 150 mm overall length floor stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and as directed.
50S&F Mild steel 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and as directed.
51S & F aluminium handle, cast type anodized 150mm size complete all as specified and as directed.
52S & F 150 mm long aluminium anodized barrel tower bolts of extruded section complete all as specified and as directed.
53S & F 200 mm long aluminium anodized barrel tower bolts of extruded section complete all as specified and as directed.
54Supply & fixing butt hinges medium weight cold rolled mild steel of 100mm long complete all as specified and directed.
55Supply & fixing Stainless Steel butt hinges medium weight of 100mm long complete all as specified and directed.
56Supply & fixing butt hinges medium weight cold rolled mild steel of 50mm long complete all as specified and directed.
57Taking down cement plaster on brick or stone or concrete walls etc raking out joints hacking for key scrabbing down water etc including taking out/removal of the all the tree routes from the brick surface/concrete surface complete all as specified and directed.
58Material and labour for 15mm thick cement plaster in CM (1:4) on fair faces of brick or concrete surfaces mixed with WPC where ever requiredas per manufacturerer"s instructions and finishing the surface even and smooth (without using extra cement) complete all as specified and directed NOTE -WPC shall be measured and paid separetely.
59M&L for rendering 15mm thick on fair faces of brick work in CM 1:6 finished even and fair complete all as specified and directed
60M&L for rendering 10mm thick in CM (1:3) on fair facesof concrete as in ceiling surfaces finished even and fair complete all as specified and directed
61Supply only WPC complete all as specified and directed.
62M&L for applying two coats of synthetic eneamel painting over a coat of pink primer on new wooden surfaces of any description exc 10 cm width or girth including preparation of new surfaces complete all as specified and directed.
63M&L for two coats of synthetic enamel painting over a coat of red oxide zinc chrome primer on steel surfaces of any description over 10cm width or girth including preparation of new steel surface complete all as specified and directed
64M&L for preparing new plastered or unplastered surfaces of walls and applying two coats of distemper oil emulsion paint complete all as specified and as directed.
65M&L for preparing new plastered or unplastered surfaces of ceiling and applying two coats of distemper oil emulsion paint complete all as specified and as directed
66M&L for preparing old decorated surfaces of walls and applying one coat of oil bound distemper to match the existing surface complete all as specified and as directed
67M&L for preparing newly plasteredsurfaces of walls and applying two coat of cement base paint over a coat of primer complete all as specified and as directed
68M&L for preparation of old decorated plastered or unplasteredsurfaces of walls including cornices etc by brooming down with steel wire brushing, scraping down smoke soot, moulds, masss and efflorscent salts and trading oil and greasy spots & removing of nails mark & applying one coat of cement base paint on wall complete all as specified and directed
69M&L for providing PCC 1:2:4 type B-0 (using 12.5mm graded stone aggregate) as in roof kerbs or mud stops rouded or chamfered on edges complete all as specifed and directed.
70M&L for 50mm thick (laid in two equal layer of 25 mm thick) inPCC 1:2:4 type B-0 (using 12.5mm graded stone aggregate)includingfinishing even and fairas in roof padding and preparing surface to receivetreatment complete all as specified and directed.
71S & F 1.4mm dia galvanised steel wire netting 20mm X 20mmmesh size , madeup into matteresses or cages, lapped, wired and laid in position, incl fixed with tinned tacks of wire staples complete all as specifed and directed.
72M&L for APP based polymeric membrane minimum weighing 3.60Kg/Sqm and minimum 3mm thick reinforced with polyster non woven fabric ( weight not less than 150 gms /sqm ) laid on bituminous surfaces by forced application over entire roof area, sunken portionwith side lap not less 100mm and end lap not less than 150mmincluding applying a tack coat of industrial bitumen 85/25 grade@1.2 Kg/Sqmover a coat ofbitumenprimer @ 0.30 Kg/ sqm including cleaning surfaces etc complete all as specifed and directed.
73Dismantling water tanks of capacity exc 250 but not exc 500 ltr capacity including disconnecting from existing pipe line complete all as specifed and directed.
74Supply & Fixingrotational moulded polythene water storage tanks tripple layer(cylindrical vertical with closed top) hoisted and fixed in postion 500 ltrs capacity with and including 20mm dia ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe minimum weight 210 gramcomplete all as specified and directed.
75S&F MS framed work such as grills,gratings, etc with ends of bars shouldered and / or riveted or forged into spikes; framed guard ; barred iron doors; ladders ; framed balusters; walk ways; railing and simillar work Con-forming to Fe 290 Gde E-165 complete all as specified and directed.
76M&L for 75mm thick cement concrete 1:3:6 type C-1 (using20mm graded stone aggregate) as in plinth protection laid in bays, incl all necessary form work & finishing surface even & smooth using extra cement complete all as specified and as directed.
77S&FSteel rolling shutters, thickness of laths in 1.25 mm, without ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: push pull or manual type complete all as specified and as directed
78BOQ ( Sch "A") E/M Suppy, fixing, transporting, erecting and fixing steel tubular swaged pole type 410 SP- 31 (09metres long) complete with cast iron base plate, finial taper plug MS bolts, and washers incuding two coats of aluminium paint over a coat ofred oxide primer to external surfaces of steel tubular pole and two coats ofanti corrosive bituminous paint internally and externally upto planting depth of pole and providing 3 bands/ straps with paint red post office colour and 2 bands with black synthetic enamel paint 300mm from plinth block and marking pole No. with black synthetic enamel paint of suitable size/font and feeder location of Pole including earth work/excavation in any type of soil PCC 1:4:8 type D-2 in foundation below pole, PCC 1:3:6 type C-2 around pole and plinth block of pole, disposal of surplus soil to a distance n.exc 50m and depositing where directed including dismantling of existing damaged steel pole/struts etc complete all as specified and directed.
79M&L for in repairs mild steel work Fe-290 grade-E-165 in cross arms, bracing, supports,clamps and back plate, fabricated from structural steel section including nuts bolts and washers, welding, bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and including applying two coats of aluminium paint over a coat of red oxide primer including dismantling cross arms of mildsteel channel or angle section etc complete all as specified and directed.
80Supply and fixing in repairs pin type, porelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100 mm height,65mm dia for 1100 volts grade complete all as specified and directed
81Supply and fixing in repairs shakle type, porelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers, insulator bolts, washers and nuts insulators suitable for working pressure in 1100 volts of height 75 mm and max dia 90mm alongwith galvanised steel fittings section of straps in 31X3 mm and dis of bolts 12mm complete all as specified and directed
82M&L for in repairs MCCB 4 pole 415V adjustable type 200 Amps with breaking capacity 36 KA complete all as specified and directed
83M&L for in repairs MCCB 4 pole 415V adjustable type 250 Amps with breaking capacity 36 KA complete all as specified and directed
84M&L for in repairs MCCB 4 pole 415V adjustable type 630 Amps with breaking capacity 50 KA complete all as specified and directed
85M&L stay assembly complete comprising of 7/3.15 galvanised stranded stay wire of required length fixed to pole with and including FI clamp 50x6mm size, bolts, nuts washers, galvanized steel stay rod 16mm dia and 1800mm long , stay bow 400 x 14 mm galvanisedsteel plate 230 x 230 x 6 mm two numbers,thimblesloop insulator size 90 x 140mm clearancehole 16 mm including earth work/excavation in any type of soil, PCC 1:3:6 type C-2 in foundation of stay assembly, disposal of surplus soil to a distance of 50m including two coats of aluminium paint over a coat of red oxide primer on exposed mild steel work including dismantling existing stay assembly etc complete all as specified and shown in electric plate No 1 and directed.
86M&L for following over head conductor (ACSR) on existingLT steel tubular pole or RS joistLT electric pole including binding and jointing the conductor with and including 14 SWG winding wire etc complete all as specified and directed. Note:- If any damage in insulator occurs while carrying out work, the same shall be replaced by the contractor at his own cost and the cost of insulator shall deemed to be included in unit rate quoted by contractor (a) Weasel (6/1x2.59 aluminium and 1x2.59 steel)
87M&L for stringing, drawing of GI wire 4 mm dia onLT electric lines including binding, jointingand for guarding cradle made to shape hexagonal/rectangular or any shape fabricted etc complete all as specified and directed.
88M&L for in replacement of danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white with letter figures and conventional skull and bones in signal red colour and fixed with suitable size MS clamps bolts and nuts of approved size for LT 20x15 cm sizeetc complete all as specified and directed.
89Supply and fixing or passing through pipe, stranded conductor 6 Sqmm, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers no more than 1 meter apart including 4 mm suspension wire, one twin core cable flat or circular etc all as specified and directed.
90Supply and fixing or passing through pipe, stranded conductor 10 Sqmm, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers no more than 1 meter apart including 4 mm suspension wire, one twin core cable flat or circular etc all as specified and directed.
91Supply and fixing or passing through pipe, stranded conductor 16 Sqmm, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers no more than 1 meter apart including 4 mm suspension wire, one twin core cable flat or circular etc all as specified and directed.
92Supply, laying , connecting, testing and commissioningof150 Sqmm 3.5 core under ground LT cable XLPE insulated screened, PVC bedded, armoured heavy duty electric cable with stranded aluminium conductor 1100 Volts laid in trenches, fixed to walls/ drawn through pipe and incl the disturbence surface of road making good with using PCC, fixing the cable with suitable size glands, crimping type lugs etc all as specified and directed. Note-(Excavation and earth work, sand cushioning and cable cover protection shall be measured and paid for separately.)
93All as per item No 92 above but 70 Sqmm 3.5 core
94All as per item No 92 above but 50 Sqmm 3.5 core
95All as per item No 92 above but 16 Sqmm 2 core
96Supply and fixing in repairs LED street light fittings 60 watt, 230 V AC out door type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp braket with impact and corrosion resistant including thermal management in multiple optics complete with IP65/66 protection, average life of street light shall not be less than 50000 hours, inluding clamps, nut, bots, bracket made of GI pipe light grade dia 32mm, length not less than 1.5m, bent to shape for LED fitting for fixing of LED light on electric LT pole including 2 sqmm PVC twin core aluminium cable from conductor to street light not less 2.0 metre , testing complete all as specified and directed.
97Supply and fixing in repairs LED flood light 70 watt, 230 V AC out door type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp and average life of flood light shall not be less than 50000 hours, including clamps, nut, bots, bracket made of GI pipe light grade dia 32mm, length not less than 1.5m, bent to shape for LED light fitting for fixing of LED light on electric LT pole including 2 sqmm PVC twin core aluminium cable from conductor to street light not less 2.0 metre , testing to satisfaction of Engineer in chargecomplete all as specified and directed. Make :- Havells, Philips, Wippro, Bajaj .
98M&L for Earthingcomplete with galvanized steel earthplate electrodes 60x60x6.3 mm thick buried directly in ground (earth pit not less than 2. 25mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level connected to galvanized iron strip 25 x 4 mm as earthing lead by means of bolts, nuts , check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3and including excavation and earth work in any type of soil/disintegrated rock, GI pipe light grade 15 mm bore for protection of GI wire from earth electrode to and incl the earth test point of galvanized Iron/steel of size 75x75x 25mm,supplying and laying charcoal dust, common salt, PCC 1:2:4 typeB1 chamber and MS angle iron frame 40x40x3mm and RCC cover 40mm thick (1:2:4) type B1 using 20mm graded stone aggregate reinforced with 6 mm dia TMT bars @ 75mm C/C both ways with MS handle 12mm dia, PGI funnel and wire mesh,20 mm dia GI pipe light grade for wateringand connected to earth test point including brazing at all joints except at test point and testing complete all as specified and directed Note- On testing after completion of job, if desired earth resistance is not obtained, the earthing shall be redone by the contractor at his own expenses without any extra cost to Govt.
99Excavation in trenches not exceeding 1.5 mtr wide and not exc 1.5mtr in depth and getting out in hard/dense soil complete all as specified and directed
100Returning, fillingin incl spreading, levelling, watering and well ramming in layers not exc 25 cm in hard/dense soil all as specified and directed.
101Removing excavated material (soil) to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above thestarting point complete all as specified and directed.
102M&L for dry clean sand filling in trenches below and around under ground cable cushioning complete all as specified and directed. Note :-Thickness of sand cushioning shall be measured after punning.
103Supply and fix unreinforced precast PCC cable cover class LV type I of size 0.25x0.15x0.40mm complete all as specified and directed
104M&L for in repairs GI tubing light grade 80 mm bore for cable protection laid in trenches/fixed to wall, poles including suitable size MS flat iron, clamps,nuts, bolts, etc complete all as specified and directed
105S&F in repairs cable jointing kit for 1.1 KV grade cable for stairght through joint complete with jointing material (Epoxy based) and accessories suitable for 3.5 core XLPE armoured Al conductor cable of size 185 sqmm to 240 sqmm complete all as specified and directed
106All as per item No 105 above but cable of size 120 sqmm to 150 sqmm.
107All as per item No 105 above but cable size 50 sqmm to 95 sqmm.
108M&L for preparation of old painted steel and iron surfaces and painting to steel tubular LT poles with two coats of synthetic enamelled paint upto 1.5 m height above from ground level/plinth block (in yellow, Red and black strips of 30 cm wide each) and applying two coats of aluminium paint above 1.5 m height of poles including painting on cross arms, bracing, clamps etc and writing pole Nos with thick black synthetic enamel paint complete all as specified and directed
109M&L for stringing stretching and stengthening of over head conductor (ACSR) on existingLT steel tubular pole or RS joistLT electric pole including binding and jointing the conductor with and including 14 SWG winding wire etc all as specified and directed. Note- (i) Unit rate quoted by contractor shall deemed to be included cutting/trimming of tree branches all around the LT over head conductor of any span upto 1.5m away including removing. (ii) If any damage in insulator occurs while carrying out work, the same shall be replaced by the contractor at his own cost and the cost of insulator shall deemed to be included in unit rate quoted by contractor (a) Weasel (6/1x2.59 aluminium and 1x2.59 steel)
110Taking down unserviceable panel including supply and fixing CPRI approved panel boxconcealed in wall , double door type with die cast type made all of 18 guage CRCA sheet of suitable size for fixing of KWH meters MCCB, MCB, Bus bars etc as per IE rules comprising of following and necessary wiring for MCBs, meters- 05 Nos. with Locking arrangements and optical glass over the electronic meter (a)S&FMCCB 100Amps 415 volt, TPN, 25 KA - 01 No (b)S&FMCB SPN 63Amps - 5 Nos (c) Space and mounting brackets for fixing of 5 Nos single phase KWH meters. (d)Fixing only the existing electronic meter as per existing sl No. of qtr.
111Taking down existing panel including supply, installation and testing of CPRI approved LT Feeder Pillar (prewired) board outdoor type made with CRCA sheet minimum 3.15mm thick suitable for 415 Volt, 50 Hz, the feeder pillar panel should be CPRI certificate IP-54 with switchgearcomplete with dust and vermin proof, rain shed on top, Panel board should have front and rear opening with hingeddouble door and rubber gaskets, handles, industrial lucking arragements, earthing terminals, affixing danger notice board and anti rust coating , suitable cable entryand exist hole including cable glands with angle base (50 x 50 x 6) mm fixing in PCC with size of panel 1500 x 1500 x 700 mm with following accessories:- (a) 4 Pole MCCB 250 Amp, 50 Hz, 415 V with rupturing capacity 36 KA - 01 No (01 No for Incoming) (b) Aluminium Bus bar capacity 400 Amps-06 Nos (0.8 mtr) for suitable for 15 Nos cable out going (c) Ammeter Digital Type-01 Nos. (d) Voltmeter Digital Type-01 Nos. (e) Amp selector switch-01 Nos (f) Voltmeter selector switch - 01 Nos. (g) LED indicating lamp (R, Y,B)-01 Nos.
112Taking down existing panel including supply, installation and testing of CPRI approved LT Feeder Pillar (prewired) board outdoor type made with CRCA sheet minimum 3.15mm thick suitable for 415 Volt, 50 Hz, the feeder pillar panel should be CPRI certificate IP-54 with switchgearcomplete with dust and vermin proof, rain shed on top, Panel board should have front and rear opening with hingeddouble door and rubber gaskets, handles, industrial lucking arragements, earthing terminals, affixing danger notice board and anti rust coating , suitable cable entryand exist hole including cable glands with angle base (50 x 50 x 6) mm fixing in PCC with size of panel 1500 x 1500 x 700 mm with following accessories:- (a) 4 Pole MCCB 250 Amp, 50 Hz, 415 V with rupturing capacity 36 KA - 01 No (01 No for Incoming) (b) TPN 100 MCB, 25 KA -04 (OUT GOING) (c) Aluminium Bus bar capacity 400 Amps-06 Nos (0.8 mtr) for suitable for 6 Nos cable out going. (d) Ammeter Digital Type-01 Nos. (e) Voltmeter Digital Type-01 Nos. (f) Amp selector switch-01 Nos (g) Voltmeter selector switch - 01 Nos. (h) LED indicating lamp (R, Y,B)-01 Nos.
113Taking down existing panel including supply, installation and testing of CPRI approved LT Feeder Pillar (prewired) board outdoor type made with CRCA sheet minimum 3.15mm thick suitable for 415 Volt, 50 Hz, the feeder pillar panel should be CPRI certificate IP-54 with switchgearcomplete with dust and vermin proof, rain shed on top, Panel board should have front and rear opening with hingeddouble door and rubber gaskets, handles, industrial lucking arragements, earthing terminals, affixing danger notice board and anti rust coating , suitable cable entryand exist hole including cable glands with angle base (50 x 50 x 6) mm fixing in PCC with size of panel 1500 x 1500 x 700 mm with following accessories:- (a) 4 Pole MCCB 250 Amp, 50 Hz, 415 V with rupturing capacity 36 KA - 01 No (01 No for Incoming) (b) TPN 100 Amp MCB, 25 KA -04 (OUT GOING) (c) SPN 63 Amp, MCB-04 Nos (OUT GOING) (d) Ammeter Digital Type-01 Nos. (e) Voltmeter Digital Type-01 Nos. (f) Amp selector switch-01 Nos (g) Voltmeter selector switch - 01 Nos. (h) LED indicating lamp (R, Y,B)-01 Nos.
114Taking down existing panel including Supply, installation and testing of CPRI approved LT Feeder Pillar (prewired) board outdoor type made with CRCA sheet minimum 3.15mm thick suitable for 415 Volt, 50 Hz, the feeder pillar panel should be CPRI certificate IP-54 with switchgearcomplete with dust and vermin proof, rain shed on top, Panel board should have front and rear opening with hingeddouble door and rubber gaskets, handles, industrial lucking arragements, earthing terminals, affixing danger notice board and anti rust coating , suitable cable entryand exist hole including cable glands with angle base (50 x 50 x 6) mm fixing in PCC with size of panel 1500 x 1500 x 700 mm with following accessories:- (a) 4 Pole MCCB 250 Amp, 50 Hz, 415 V with rupturing capacity 36 KA - 01 No (01 No for Incoming) (b) TPN 100 MCB, 25 KA -04 (OUT GOING) (c) Aluminium Bus bar capacity 400 Amps-06 Nos (0.8 mtr) for suitable for 6 Nos cable out going. (d) Ammeter Digital Type-01 Nos. (e) Voltmeter Digital Type-01 Nos.
115Supply and fixing Bus bar chamers 100 Amps 4 Nos Aluminium Bus BAR (0.6 Meter length) wall mounted or fixing on ground with mounting suitable angle iron with PCC Basefor suitable for incoming and out going Cablenut and bolts including lugs& cable glans complete as specified and directed
116Supply and Fixing pole mounting box / junction box made out of 1.66mm thick MS CRCA sheet / fibre sheet of size 230 x170 x 105 mm completesuitable for three phase connection with clamps of flatiron/GI off size 25 x 4 mm including suitable size nut, bolts, washer etc to fix on pole and provide with hinged door and locking system all painted with two coats of synthetic enamel paints over one coated red oxide paint and comprising of thefollowing :- (i)AI busbar 150mm long size 20 x 50 mm fixed onfour Nos porcelain insulator each busbar provided with four Nos of Nuts, bolts, washer for incomingandout going cable. (ii)MCB SP 230V 5 to 32A, 10 KA – 1 Nos.
117Supply and Fixing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 6 sqmm2 Core from junction box to street light pole to street light complete all as specified and directed
118Supply and Fixing PVC pipe having 20 mm bore for cable protection in pole from junction box to street light fittings complete all as specified and directed
119Trimming of trees all as along the LT line in such away that there is clear distance of 3.00 mtr between tree and electric line.The work will be executed to the entire satisfaction of Engineer-in-charge irrespective of the size of the tree branches etc complete all as specified and directed. Note :- (1). Tree branches will be left as it is the wood belong to cantt board/DO.They will be responsible for the wood. (2)Contractor will employ sufficient labour to complete the full above one job within 15 days. (3).Contractor will be responsible for any type of accident while trimming the trees.(4)Contractor superviser will take proper shut down from MES installation before starting the work and clear it before resuming power supply,however full assistant will be provided by MES staff.
120M & L for preparation and Submit of earthing test certificate at E/M installation at Haldwani, Kamola and Ranibagh in presence of Engr-in-Charge and make a testing certificate and Submitted at E/M office with signed by Engr-in-Charge as specified and directedNote:- All tools and plants for earthing test shall be provided by contractor with skilled Electrician at his own cost.
121M&L for preparation of External Electric Lay out diagram chart from Main Receiving to All Sub Stn with LT Panel including HT and LT Cable Line as per direction of Engr-in-Charge with proper laminated frame with cololour Legand as per specified and directed by Engr-in-Charge. Note:- Size of chart as per direction of Engineer-in-Charge.
122M&L for preparation of External Water supply pipe line Lay out diagram chart from Pump house underground Sump to all OH Tank and other line as per direction of Engr-in-Charge with properlaminated frame with cololour Legand as per specified and directed by Engr-in-Charge. Note:- Size of chart as per direction of Engineer-in-Charge.
123Trimming of trees all as along the Fencing of Sub Station of A, B, C and around DG Setin such away that there is clear from fencing or E/M installation as suchofof 3.00 mtr distance.The work will be executed to the entire satisfaction of Engineer-in-charge irrespective of the size of the tree branches etc complete all as specified and directed. Note :- (1). Tree branches will be left as it outside of fencing and in Cantt board/DO.They will be responsible for the wood. (2).Contractor will be responsible for any type of accident while trimming the trees.(3)Contractor superviser will take proper shut down from MES installation before starting the work and clear it before resuming power supply,however full assistant will be provided by MES staff.
124Surface dressing n.exc 15 cm deep in any type soil including taking out all sapling shrubs, bushwood, undergrowth, roots, and trees n. exc 30 cm girth all removing to a distance n.exc 100 m from starting point complete all as specified and directed by Engr-in-charge (The area is to be carried out in and around,structches viz transformes, HT and electric poles over head reservoirs, around power house and pump house and other E/M installation at Haldwani & Ranibagh).
125Taking up or down old unserviceable 50mm dia (bore) GI Water Tubing and Connections and removing from site complete all as specified and as directed.
126Taking up or down old unserviceable 40mm dia (bore) GI Water Tubing and Connections and removing from site complete all as specified and as directed.
127Taking up or down old unserviceable 32mm dia (bore) GI Water Tubing and Connections and removing from site complete all as specified and as directed.
128Taking up or down old unserviceable 20mm dia (bore) GI Water Tubing and Connections and removing from site complete all as specified and as directed.
129Re-fixing of 50mm dia (bore) old steel water tubing and connection in new or old position as in trenches including cleaning of old pipes and provision of new GI fittings as required complete all as specified and directed. Note :- Serviceable GI tubing retreived from taking down shall be reused.
130Re-fixing of 40mm dia (bore) old steel water tubing and connection in new or old position as in trenches including cleaning of old pipes and provision of new GI fittings as required complete all as specified and directed. Note :- Serviceable GI tubing retreived from taking down shall be reused.
131Re-fixing of 32mm dia (bore) old steel water tubing and connection in new or old position as in trenches including cleaning of old pipes and provision of new GI fittings as required complete all as specified and directed. Note :- Serviceable GI tubing retreived from taking down shall be reused.
132Re-fixing of 25mm dia (bore) old steel water tubing and connection in new or old position as in trenches including cleaning of old pipes and provision of new GI fittings as required complete all as specified and directed. Note :- Serviceable GI tubing retreived from taking down shall be reused.
133Re-fixing of 20mm dia (bore) old steel water tubing and connection in new or old position as in trenches including cleaning of old pipes and provision of new GI fittings as required complete all as specified and directed. Note :- Serviceable GI tubing retreived from taking down shall be reused.
134Re-fixing of 15mm dia (bore) old steel water tubing and connection in new or old position as in trenches including cleaning of old pipes and provision of new GI fittings as required complete all as specified and directed. Note :- Serviceable GI tubing retreived from taking down shall be reused.
135Supply and laying in trenches 50mm dia (bore) GI tubing medium grade with all GI fittings(such as bend, elbow, tees, connectons, short pieces, bak nuts, union, valve, caps and plugs etc) for pipe complete all as specified and directed
136Supply and laying in trenches 40mm dia (bore) GI tubing medium grade with all GI fittings(such as bend, elbow, tees, connectons, short pieces, bak nuts, union, valve, caps and plugs etc) for pipe complete all as specified and directed
137Supply and laying in trenches 32mm dia (bore) GI tubing medium grade with all GI fittings(such as bend, elbow, tees, connectons, short pieces, bak nuts, union, valve, caps and plugs etc) for pipe complete all as specified and directed
138Supply and laying in trenches 20mm dia (bore) GI tubing medium grade with all GI fittings(such as bend, elbow, tees, connectons, short pieces, bak nuts, union, valve, caps and plugs etc) for pipe complete all as specified and directed
139M&L for making good the leaking of upto 150 mm bore GI/CI pipe lines by welding all around the pipe, thickness of metal to be welded exc 9 mm but n exc 20 mm respectively including all necessary excavation and earth work removal of old joints etc complete all as specified and directed. Loc : Pump House, Haldwani, Ranibagh & Kamola
140Taking out sluice valve suitable for 150 mm bore pipe from valve pit for re-facing & re-grinding and re-fixing, including all jointing material such as nut, bolts, washers, rubber gasket/packing 6 mm thick, including glan packing etc and asrequired at site complete all as specified and directed.Loc : Pump House, Haldwani, Ranibagh & Kamola
141All as per item No 140 above but of size 100 mm size sluice valve.
142All as per item No 140 abovebut of size 80 mm size sluice valve.
143Taking out old unserviceable sluice valve from valve pit or vertical line of overhead tank valve and supply, Install, commissioning and testing of 150 mm size sluice valve of cast iron body flanged & drilled conforming to IS-14846, PN-1.00 with stainless steel spindle including all accessories such as nut-bolts, washers & fibre/rubber gasket as required at site complete all as specified and directed.
144All as per item No 143 above but of size 100mm size sluice valve
145All as per item No 143 above but of size 80mm size sluice valve
146Removing water meters, any pattern from bore of pipes 20 mm by unscrewing unious, fitting unions with screw plugs, or inserting short length or tubing screwed both ends so as to maintain supply all as specified and directed. Note: After removing all water meters shall be deposited to MES store by the contractor at his own cost.
147Taking out old unserviceable cast iron Non return valveof any type and size for replacement and supplying, fixing, testing and commencing non return valve suitable for 100/80 mm bore pipe (suction line)both ends flanged including nut bolts, gasket and washer from sump and pump house bldg complete all as specified and directed. Loc : Pump House Haldwani, Ranibagh & Kamola
148Material & Labourfor repair and overhauling of elect motor 30 HP capacity installed with pump set atpump house, Haldwani comprising of the following works :- (a)Dismantling of 30 HP elect motor 3 phase, 440 volts from foundation and taking away local works shop and transporting back the same after repairs. (b)Opening of motor winding, cutting of burnt coils and cleaning of slots complete all as specified and directed. (c)Applying one coat of red oxide primer, fixing of packing with Pnumax paper and green sheet of glass cloth, rewinding with suitable gauge of super enamelled insulated wire (Appx qty- 25 Kg) (d)Making suitable Star/Delta connections for three phase wiring with 6 Sqmm x 6 run (Appx 24 RM) of FRLS wire incl PVC pipe and pin type lugs complete all as specified and directed. (e)Varnishing with doctor bake varnish, during backtrol and heating properly complete all as specified and directed (f)Replacement of unserviceable rubber star coupling and providing new pin bush coupling complete all as specified and directed. - 01 Nos (g) Repair of Main shaft of pump. (h) Replacement of Pump bearingsuitable size and fillup grease for lubrication complete all as specified and directed. - 02 Nos (j) Repalcement of imppellers suitable size. - 02 Nos (k) Replacement of pump bushes of suitable size. (l) Replacement in repair Gland packing, greasing to brgs. Notes :-Standby electric motor of 30 HP shallbe provided by the contractor at the site without any extra cost.
149All as per item No. 148 above but electric motor of capacity10 HP installed at MES pump house Haldwani complete all as specified and directed.
150M&L for in repairs for opening of CI sluice valve of 150 mm size any type for replacement of defective spindle with stem and providing new spindle with stem made of stainless steel duly machine threaded, heat treated and shaped including cast iron handwheeland making good the stuffing box with suitable size of gland packing and greasing at Haldwani & Ranibagh complete all as specified and directed.
151All as per item No 150 above but of size 100 mm size sluice valve.
152All as per item No 150 above but of size 80 mm size sluice valve.
153Excavation in trenches by manually or mechanical method n.exc. 10 Sqm on plan,exc. 1.5 m deep butn.exc. 3.0m in deep for foundation etc. in hard/ dense soil including taking out old filler material from the mild steel pipe joint including cleaning of joints and making the joints completely water tight and air tight by means of lead joint & filler material to the entire satisfaction of Engineer in charge includingretuning/ filling, to be done after joints are sealed complete all as specified and directed. Note :- The rate quoted by the contractor shall deemed to included of all T & P and material , nothing extra shall be paid.
154M & Lfor in repairs and replacement of contactor/relay with necessary connected partrs including wire in startor panel of 30 HPat pump house Haldwani complete all as specified and directed.
155M & Lfor in repairs and replacement of contactor/relay with necessary connected partrs including wire in startor panel of10 HP at pump house Haldwani complete all as specified and directed.
156Trimming of trees around the Over Head Tankand there is clear from of 3.00 mtr between tree and Over Head Tank.The work will be executed to the entire satisfaction of Engineer-in-charge irrespective of the size of the tree branches etc complete all as specified and directed. Note :- (1). Tree branches will be left as it outside of fencing and in Cantt board/DO.They will be responsible for the wood. (2).Contractor will be responsible for any type of accident while trimming the trees.(3)Contractor superviser will take proper shut down from MES installation before starting the work and clear it before resuming power supply,however full assistant will be provided by MES staff.
157Supply andRefilling Gas/refrigerant (CFC free)in AC 1.5 ton / 2 Ton complete all as specified and directed
158Supply andRefilling gas/refrigerant in Refrigerator having capacity 165 to 315 ltr complete all as specified and directed
159Supply andRefilling Gas charging in Water cooler of capacity upto 60/120 Ltr complete all as specified and directed
160Supply, fixing and commissioning of Compressor for window, 1.5 ton capacity Air Conditioner (AC) complete all as specified and directed
161Supply, fixing and commissioning of Compressor for Split AC, 1.5 ton Capacity complete all as specified and directed
162Supply, fixing and commissioning of Compressor Split and window, 2 ton complete all as specified and directed
163Supply, fixing and commissioning Refrigerator compressor of capacity 165 to 180 ltr complete all as specified and directed
164Supply, fixing and commissioning Refrigerator compressor of capacity 210 to 315 ltrs complete all as specified and directed
165Supply, fixing and commissioning Water cooler compressor of capacity 40/80 ltr complete all as specified and directed
166Supply, fixing and commissioning Water cooler compressor of capacity 60/120 ltr complete all as specified and directed
167Supply, fixing and commissioning of relay for split and window AC upto capacity 2 Ton complete all as specified and directed
168Supply, fixing and commissioning of relay for Refrigerator upto 315 Ltr capacitycomplete all as specified and directed
169Supply, fixing and commissioning of PCB for split/window AC including inverter Split ACupto 2 ton capacity complete all as specified and directed
170Supply and fixing Electronic control PCB for refrigerator upto 315 Ltr capacity all as specified and directed
171Supply and fixing Thermostat of window/split AC of any capacity complete all as specified and directed
172Supply and fixing Thermostat of Refrigerator any capacity complete all as specified and directed
173Supply and fixing Thermostat of Water cooler of any capacity complete all as specified and directed
174Supply and fixing blead with motor Split/window AC of capacity 1.5 TR to 2 TR complete all as specified and directed
175Supply and fixing Fan motor Water cooler of capacity upto 60/120 Ltr complete all as specified and directed
176Supply and fixing swing motor for split AC of any capacity complete all as specified and directed
177Supply and fixing cooling coil for Window/SplitAC for any capcity and size complete all as specified and directed
178Supply and fixing heating coil/condenser coil for split/window AC 1.5 TR to 2 TR complete all as specified and directed
179Supply and fixing Reverse valve of AC/Refrigerator/water cooler complete all as specified and directed
180Supply, fixing and commissioning Condenser 50 mfd for Split/Window AC upto 2 Ton capacity complete all as specified and directed
181Supply and fixing timer switch for refrigerator of any capacity complete all as specified and directed
182Supply and fixing remote unit for split type ACof any model/sizeall as specified and directed
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy